1 IEEE PES Emerging Technology – July 2008 Technological Breakthroughs in Grid Revitalization The Evolving Landscape of Power Systems Vahid Madani Pacific Gas & Electric Co. PES - Emerging Technology - July 2008

Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

1IEEE PES Emerging Technology – July 2008

Technological Breakthroughsin

Grid Revitalization

The Evolving Landscape of Power Systems

Vahid MadaniPacific Gas & Electric Co.

PES - Emerging Technology - July 2008

Page 2: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

2IEEE PES Emerging Technology – July 2008

System Integrity Protection Schemes - SIPS

Page 3: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

3IEEE PES Emerging Technology – July 2008

Application Naming

Generator RejectionLoad RejectionUnder-Frequency Load SheddingUnder-Voltage Load SheddingAdaptive Load MitigationOut-of-Step Tripping Voltage Instability Advance Warning SchemeAngular Stability Advance Warning SchemeOverload Mitigation Congestion MitigationSystem Separation

Shunt Capacitor SwitchingTap-Changer Control SVC/STATCOM Control Turbine Valve ControlHVDC ControlsPower System Stabilizer ControlDiscrete ExcitationDynamic BreakingGenerator RunbackBypassing Series CapacitorBlack-Start or Gas-Turbine Start-UpAGC ActionsBusbar Splitting

Source: IEEE PSRC WG CSource: IEEE PSRC WG C--44 Global Industry Experiences with Global Industry Experiences with

System Integrity Protection SchemesSystem Integrity Protection Schemes

Page 4: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

4IEEE PES Emerging Technology – July 2008

Pie Charts: Classification (422 Entries)

46%

13%10%

11%

20%

i. Essential

ii. Increased Security

iii. Increased Power FlowCapability

iv. Important

v. Normal

Pie Chart: To provide protective actions against (53 Entries)

13%8%

26%19%

25%

9%

i. Congestion

ii. Small-Disturbance AngleInstabilityiii. Transient Instability

iv. Frequency Instability

v. Voltage Instability

vi. Thermal Overloading

Page 5: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

5IEEE PES Emerging Technology – July 2008

System to protect integrity of power system over a wide areaApplied to protect system stability, maintain overall system connectivity, and/or to avoid damage to equipments during major system eventsSystem may require multiple detection and actuation devices, and communication facilitiesLogic, design and actions are driven by the system purposeAdvanced schemes involve hierarchical architecture with several steps

RAS or SIPS

Washington

Oregon Idaho

Montana

Wyoming

Nevada UtahColorado

New MexicoArizona

AlbertaBritishColumbia

PDCI – DC Link, 1000kV

PACI – AC Corridor, 500kV

Pacific Intertie(Western ElectricityCoordinating Council)

Page 6: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

66Power Systems Computation Conference – July 2008

Caribou/ButtValley

Helms

Wheeler RidgeWind GapBuena Vista

Delta

EdmonstonPearblossom

Dos Amigos

Olinda

Tracy

Round Mt.

Neighboring Systems

SierraPacific Power

Cascade

Large Scale Coordinated SIPS

Midway

Table Mt.

Load Break InsertionsAGCGenerationReactive Support

Pacific NW Remedials

Generation Groups

Load Groups Hyatt

Maxwell

San Luis

Neighboring SystemsNeighboring SystemsNeighboring

Systems

Page 7: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

77Power Systems Computation Conference – July 2008

Multiple RAS Control CentersMultiple RAS Control Centers

Existing Comms links

ExistingControl Center

Field Devices -Keep the existingor change to new??

NewControl Center

New Comms links

Page 8: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

8IEEE PES Emerging Technology – July 2008

Current (Field Device, Phase Values Set Unbalance for Demo)

DC (milliamp) Transducer Values Set Uneven for Demo)

Voltage (Field Device, Phase Values Set Unbalance for Demo)

IEEE C37.94 @128kbpsThroughput Time – 16 milliseconds (one way)Transmission System stretch ~ 250 miles (~ 400 kilometer)

F 1

F 1

F 1

F 1 C 1

C 2C 2

C 1

Cross Over Enabled – Message is Looped

Cross Over Enabled – Message is Looped

Page 9: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

9IEEE PES Emerging Technology – July 2008

Throughput Timing – 128kbps (Excludes Controller Time ~ 10-12 msec)

Total measured time Device to Device - 16 milliseconds for one way, 250 miles (~ 425 km)

Field Device (3 milliseconds)Central Controller Device (3 msec)Channel bank field, 1.5 msecChannel bank central device, 1.5 msec

Propagation Time = [16 -(3+3+1.5+1.5] ~ 7 msec for 250 miles

For 500 miles (~850km), it is safe to say < 14 msec

Distributed Intelligence and Central ProcessingVery inefficient to transport all of the raw data only to combine the various values after the data arrives at the control centerAmount of raw data can overwhelm the bandwidthMethods to reduce the amount of raw data by pre-processing it prior to transmissionIf the mathematical combination and simplification can be done at remote sites, the required communication bandwidth is reducedLocal subsystems be designed for station-to station communication

For local coordination

Page 10: Technological Breakthroughs in Grid Revitalizationewh.ieee.org/cmte/pes/etcc/V_Madani_Grid_Revitalization.pdfIEEE PES Emerging Technology – July 2008 Pie Charts: Classification (422

10IEEE PES Emerging Technology – July 2008

Thank You

Participate:•NASPI - North American Synchronized phasor initiative

Performance Standards Task Team (PSTT)

•IEEE Power System Relaying Committee (PSRC) - SurveyWG C-4 (Global Industry Experiences with SIPS)