1
Confidential Information – Property of Banlaw Pipeline Pty Ltd ©2001 HYDROSTATIC PRESSURE & FLOWRATE TEST RESULTS Revision 3 - 2001 ****** ******** OIL & COOLANT FILL & EVACUATION ******** ****** MODEL PART No SWP ( kPa/psi) BP ( kPa/psi) MF (LPM/GPM) Crankcase AUS27W Receiver AUS29W Nozzle Coupled 10,000 / 1,450 3,000 / 435 4,750 / 690 >40,000 / >5,800 12,000 / 1,740 19,000 / 2,756 - ISO 46 Oil - 100 (26.4) Hydraulic AUS34A Nozzle AUS41A Receiver Coupled 10,000 / 1,450 10,000 / 1,450 4,000 / 580 >40,000 / >5,800 >40,000 / >5,800 16,000 / 2,320 - ISO 46 Oil - 100 (26.4) Transmission AUS32W Nozzle AUS33W Receiver Coupled 4,250 / 615 10,000 / 1,450 11,500 / 1,668 17,000 / 2,465 >40,000 / 5,800 46,000 / 6,671 - ISO 46 Oil - 30 (7.9) Coolant AUS36A Nozzle AUS37W Receiver Coupled 10,000 / 1,450 10,000 / 1,450 7,500 / 1090 >40,000 / >5,800 >40,000 / >5,800 30,000 / 4,350 - Water - 40 (10.6) (estimated) Push-To- Connect AUS38W Receiver AUS39W Nozzle Coupled 10,000 / 1,450 1,000 / 145 10,000 / 1,450 >40,000 / >5,800 4,000 / 580 >40,000 / >5,800 - ISO 46 Oil - 100 (26.4) High Flow Oil (1”) AUS80 Receiver AUS81 Nozzle Coupled 6,000 / 870 2,500 / 365 2,500 / 365 24,000 / 3,481 10,000 / 1,450 10,000 / 1,450 - ISO 46 Oil - 180 (47.6) Grease Fittings AUSGR Receiver AUSGN Nozzle Coupled 10,000 / 1,450 not applicable 9,000 / 1,305 >40,000 / >5,800 not applicable >35,000 / >5,076 not applicable ****** ******** REFUELLING EQUIPMENT ******** ****** Bulk Transfer (0-800LPM) AUSS5 Nozzle S5 and AUS23 S5 and ZN2A 4,000 / 580 7,500 / 1,088 5,000 / 725 24,000 / 3,481 30,000 / 4,350 20,000 / 2,900 800/211 Break-Away Valve AUS4W-50 (2”) AUS4W-75 (3”) 2,000 / 290 1,250 / 181 8,000 / 1,160 5,000 / 725 800 / 211 1050 / 277 Diesel Refuelling Nozzle B800 Series B800 and AUS23 B800 and ZN2A B1000 Series B1000 and AUS43 2,500 / 363 4,500 / 653 4,000 / 580 10,000 / 1,450 18,000 / 2,610 16,000 / 2,320 800 / 211 1000 / 264 LEGEND: 1. Safe Working Pressure (SWP): maximum recommended working pressure 2. Minimum Burst Pressure (BP): minimum pressure at which fitting will suffer fail 3. Maximum Flowrate (MF): maximum recommended liquid flowrate through coupled fittings – observe fluid used in points 6 & 7 4. All results refer to hydrostatic hydraulic pressure applied within fitting(s) 5. “Coupled” results refer to test conducted with nozzle and receiver engaged 6. All flow test results for Oil & Coolant Fill & Evacuation fittings obtained using test fluid as shown in table (ISO 46 Hydraulic Oil (SG 0.89) or water) 7. All flow test results for Refuelling Equipment obtained using diesoline fuel (SG 0.84, 6.5cSt) 8. Data for the AUSGN Grease Nozzle applies only to items sold after September 2001, and does NOT apply to earlier parts where the face plate was welded to the nozzle body

Technical Bulletins > Hydrostatic Pressure & Flow Test Results Rev3

Embed Size (px)

Citation preview

Page 1: Technical Bulletins > Hydrostatic Pressure & Flow Test Results Rev3

Confidential Information – Property of Banlaw Pipeline Pty Ltd ©2001

HYDROSTATIC PRESSURE & FLOWRATE TEST RESULTSRevision 3 - 2001

****** ********OIL &

COOLANT FILL& EVACUATION

******** ******

MODEL PART No SWP (kPa/psi) BP (kPa/psi) MF (LPM/GPM)Crankcase AUS27W Receiver

AUS29W NozzleCoupled

10,000 / 1,4503,000 / 4354,750 / 690

>40,000 / >5,80012,000 / 1,74019,000 / 2,756

- ISO 46 Oil -100 (26.4)

Hydraulic AUS34A NozzleAUS41A Receiver

Coupled

10,000 / 1,45010,000 / 1,450

4,000 / 580

>40,000 / >5,800>40,000 / >5,800

16,000 / 2,320- ISO 46 Oil - 100 (26.4)

Transmission AUS32W NozzleAUS33W Receiver

Coupled

4,250 / 61510,000 / 1,45011,500 / 1,668

17,000 / 2,465>40,000 / 5,80046,000 / 6,671

- ISO 46 Oil -30 (7.9)

Coolant AUS36A NozzleAUS37W Receiver

Coupled

10,000 / 1,45010,000 / 1,4507,500 / 1090

>40,000 / >5,800>40,000 / >5,800

30,000 / 4,350

- Water -40 (10.6)

(estimated)Push-To-Connect

AUS38W ReceiverAUS39W Nozzle

Coupled

10,000 / 1,4501,000 / 145

10,000 / 1,450

>40,000 / >5,8004,000 / 580

>40,000 / >5,800- ISO 46 Oil -100 (26.4)

High Flow Oil(1”)

AUS80 ReceiverAUS81 Nozzle

Coupled

6,000 / 8702,500 / 3652,500 / 365

24,000 / 3,48110,000 / 1,45010,000 / 1,450

- ISO 46 Oil -180 (47.6)

GreaseFittings

AUSGR ReceiverAUSGN Nozzle

Coupled

10,000 / 1,450not applicable9,000 / 1,305

>40,000 / >5,800not applicable

>35,000 / >5,076not applicable

****** ********REFUELLINGEQUIPMENT ******** ******

Bulk Transfer(0-800LPM)

AUSS5 NozzleS5 and AUS23S5 and ZN2A

4,000 / 5807,500 / 1,0885,000 / 725

24,000 / 3,48130,000 / 4,35020,000 / 2,900

800/211

Break-AwayValve

AUS4W-50 (2”)AUS4W-75 (3”)

2,000 / 2901,250 / 181

8,000 / 1,1605,000 / 725

800 / 2111050 / 277

DieselRefuelling

Nozzle

B800 SeriesB800 and AUS23B800 and ZN2A

B1000 SeriesB1000 and AUS43

2,500 / 3634,500 / 6534,000 / 580

10,000 / 1,45018,000 / 2,61016,000 / 2,320

800 / 211

1000 / 264

LEGEND: 1. Safe Working Pressure (SWP): maximum recommended working pressure2. Minimum Burst Pressure (BP): minimum pressure at which fitting will suffer fail3. Maximum Flowrate (MF): maximum recommended liquid flowrate through coupledfittings – observe fluid used in points 6 & 74. All results refer to hydrostatic hydraulic pressure applied within fitting(s)5. “Coupled” results refer to test conducted with nozzle and receiver engaged6. All flow test results for Oil & Coolant Fill & Evacuation fittings obtained using test fluidas shown in table (ISO 46 Hydraulic Oil (SG 0.89) or water)7. All flow test results for Refuelling Equipment obtained using diesoline fuel(SG 0.84, 6.5cSt)8. Data for the AUSGN Grease Nozzle applies only to items sold after September 2001,and does NOT apply to earlier parts where the face plate was welded to the nozzle body