Confidential Information – Property of Banlaw Pipeline Pty Ltd ©2001
HYDROSTATIC PRESSURE & FLOWRATE TEST RESULTSRevision 3 - 2001
****** ********OIL &
COOLANT FILL& EVACUATION
******** ******
MODEL PART No SWP (kPa/psi) BP (kPa/psi) MF (LPM/GPM)Crankcase AUS27W Receiver
AUS29W NozzleCoupled
10,000 / 1,4503,000 / 4354,750 / 690
>40,000 / >5,80012,000 / 1,74019,000 / 2,756
- ISO 46 Oil -100 (26.4)
Hydraulic AUS34A NozzleAUS41A Receiver
Coupled
10,000 / 1,45010,000 / 1,450
4,000 / 580
>40,000 / >5,800>40,000 / >5,800
16,000 / 2,320- ISO 46 Oil - 100 (26.4)
Transmission AUS32W NozzleAUS33W Receiver
Coupled
4,250 / 61510,000 / 1,45011,500 / 1,668
17,000 / 2,465>40,000 / 5,80046,000 / 6,671
- ISO 46 Oil -30 (7.9)
Coolant AUS36A NozzleAUS37W Receiver
Coupled
10,000 / 1,45010,000 / 1,4507,500 / 1090
>40,000 / >5,800>40,000 / >5,800
30,000 / 4,350
- Water -40 (10.6)
(estimated)Push-To-Connect
AUS38W ReceiverAUS39W Nozzle
Coupled
10,000 / 1,4501,000 / 145
10,000 / 1,450
>40,000 / >5,8004,000 / 580
>40,000 / >5,800- ISO 46 Oil -100 (26.4)
High Flow Oil(1”)
AUS80 ReceiverAUS81 Nozzle
Coupled
6,000 / 8702,500 / 3652,500 / 365
24,000 / 3,48110,000 / 1,45010,000 / 1,450
- ISO 46 Oil -180 (47.6)
GreaseFittings
AUSGR ReceiverAUSGN Nozzle
Coupled
10,000 / 1,450not applicable9,000 / 1,305
>40,000 / >5,800not applicable
>35,000 / >5,076not applicable
****** ********REFUELLINGEQUIPMENT ******** ******
Bulk Transfer(0-800LPM)
AUSS5 NozzleS5 and AUS23S5 and ZN2A
4,000 / 5807,500 / 1,0885,000 / 725
24,000 / 3,48130,000 / 4,35020,000 / 2,900
800/211
Break-AwayValve
AUS4W-50 (2”)AUS4W-75 (3”)
2,000 / 2901,250 / 181
8,000 / 1,1605,000 / 725
800 / 2111050 / 277
DieselRefuelling
Nozzle
B800 SeriesB800 and AUS23B800 and ZN2A
B1000 SeriesB1000 and AUS43
2,500 / 3634,500 / 6534,000 / 580
10,000 / 1,45018,000 / 2,61016,000 / 2,320
800 / 211
1000 / 264
LEGEND: 1. Safe Working Pressure (SWP): maximum recommended working pressure2. Minimum Burst Pressure (BP): minimum pressure at which fitting will suffer fail3. Maximum Flowrate (MF): maximum recommended liquid flowrate through coupledfittings – observe fluid used in points 6 & 74. All results refer to hydrostatic hydraulic pressure applied within fitting(s)5. “Coupled” results refer to test conducted with nozzle and receiver engaged6. All flow test results for Oil & Coolant Fill & Evacuation fittings obtained using test fluidas shown in table (ISO 46 Hydraulic Oil (SG 0.89) or water)7. All flow test results for Refuelling Equipment obtained using diesoline fuel(SG 0.84, 6.5cSt)8. Data for the AUSGN Grease Nozzle applies only to items sold after September 2001,and does NOT apply to earlier parts where the face plate was welded to the nozzle body