Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

Embed Size (px)

Citation preview

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    1/20

    Steam TurbineProduct Overview

    GE Company Proprietary

    GE Power Systems

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    2/20

    STG Product Line

    ST Product Line Overview

    Industrial Steam

    Combined Cycle

    Coal-Fired (Fossil)

    Nuclear

    ST Design Evolution / Enhancements

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    3/20

    STG Product Line

    ST Product Line Overview

    Industrial Steam

    Combined Cycle

    Coal-Fired (Fossil)

    ST Design Evolution / Enhancements

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    4/20

    Industrial Steam Turbine

    Product Line Overview

    Impulse Technology Located in

    Schenectady, NY

    Non Reheat, Single

    Casing Units to 26

    LSB

    Direct Drive TGs to

    ~140 MW

    Energy ProductsOil & Gas -

    Nuovo PignoneOil & Gas -

    ThermoDyn

    Reaction Technology Located in Florence,

    Italy

    Direct Drive TGs 35~

    70 MWs. Limited 60

    Hz Product

    Geared TGs to ~35

    MWs

    MDTs

    Small 50 Hz Reheat

    Machines ~ 70 MWs

    Impulse Technology Located in Le

    Creusot, France

    Newly Acquired by

    O&G in July 00

    Design and Mfg of

    Steam Turbines Since

    1905

    460 Units Since 1960

    Geared TGs to ~40

    MWs

    MDTs

    BFPTs

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    5/20

    Direct Drive ST-G

    Geared ST-G

    Mechanical Drive Units

    Feed Pump Drives

    0 10 MW 25 MW 35 MW 50 MW 100 MW 15075 MW15 MW5 MW

    3-35MW

    3-60MW up to 16,000 RPM

    IST Product Line

    3-35MW

    20-140MW

    Single Flow Exhaust < 26

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    6/20

    Small Combined Cycle (IST)

    Full Range of STGs to Fully Integrate With a

    Chosen Heat Balance

    Full Range of STGs to Fully Integrate With a

    Chosen Heat Balance

    Integrated with GE Gas Turbines

    Product Characteristics / Features:

    Base Mounted for Ease of Installation

    Advanced Steam Path Designs

    Fixed or Sliding Pressure Inlet Design

    Complete Product Coverage withProven Exhaust Sections

    Reheat / Non-Reheat Alternatives

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    7/20

    Steel

    Pulp & Paper

    Petrochemical

    Industrial IPP

    Industrial Cogeneration

    GE Strengths

    Multiple Internal Extractions

    Packaging Flexibility

    High Volume Inlet Flow Capability (1.2 MPPH)

    Axial / Down Exhaust Configurations

    Applications:

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    8/20

    MDT's, 2,500 HP to 80,000 HP

    6

    Mechanical Drive Steam Turbines

    BFPT's, 3-35 MW

    Single or Double End Drive Inlet Steam up to 1800 psig / 1000F

    Product Line Characteristics

    Product Applications

    Utility Boiler / Reactor Feed Pumps

    LNG

    Refineries

    Process Air

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    9/20

    STG Product Line

    ST Product Line Overview

    Industrial Steam

    Combined Cycle

    Coal-Fired (Fossil)

    ST Design Evolution / Enhancements

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    10/20

    Typical Ratings: Actual Ratings Depend on Steam Conditions,Back Pressure and Other Cycle Parameters

    0 50 100 150 200 250 300 350 400

    1450 / 1000( PSI / F )

    C Series

    D Series ( D10 / D11)

    A Series

    Steam Turbine Output (MW)

    Typical Ratings - 50 and 60 Hz

    SC Series

    Combined Cycle Products

    Non -

    Reheat

    Reheat Up to 2400 / 1050 / 1050( PSI / F / F )

    100 / 538

    ( Bar / C )

    Up to 166 / 566 / 566( Bar / C / C )

    Last Stage Bucket Lengths

    50 Hz 60 Hz

    660 mm (26) 508H mm (20H)

    851 mm (33.5) 660 mm (26)

    1064 mm (42) 762 mm (30)

    1219 mm (48) 851 mm (33.5)

    1016 mm (40)

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    11/20

    Reheat Product Line Bread & Butter

    D11/D10Product Characteristics: Power Rating: 120 425 MW

    Nominal Steam Conditions:1800 psig / 1050 F / 1050 F

    Arrangement: Combined HP/IP 2 Flow LP

    Double Flow LPs60 HZ: 2 x 20H / 2 x 30 / 2 x 33.5 / 2 x 4050 HZ: 2 x 26 / 2 x 33.5 / 2 x 42 / 2 x 48

    Experience:1st Unit C.O.D 1993

    Units Shipped: 105

    > 150 Units Committed Since 2000

    A-Series Product Characteristics: Power Rating: 85 150 MW

    Nominal Steam Conditions:1800 psig / 1050 F / 1050 F

    Arrangement: HP + Combined IP/LP

    Single Flow LPs60 HZ: 1 x 33.5 / 1 x 4050 HZ: 1 x 33.5 / 1 x 42 / 1 x 48

    Experience:1st Unit C.O.D 1991

    Units Shipped: 33

    Total Units: 46

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    12/20

    STG Product Line

    ST Product Line Overview

    Industrial Steam

    Combined Cycle

    Coal-Fired (Fossil)

    ST Design Evolution / Enhancements

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    13/20

    Typical ratings; Actual ratings depend on steam conditions,back pressure and other cycle parameters.

    0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950

    2400

    PSI

    3500

    PSI

    2400

    PSI

    3500PSI

    60

    Hz

    D Series

    G Series - 4 Casing

    D Series

    G Series - 4 Casing

    D Series

    G Series - 4 Casing

    A Series

    D Series

    G Series - 4 Casing

    Steam Turbine Output (MW)

    G Series - 3 Casing

    G Series - 3 Casing

    Typical Ratings - 50 and 60 Hz

    G Series - 3 Casing

    A Series

    G Series - 3 Casing

    Coal-Fired Steam Turbine

    50Hz

    Product Line Offerings Last Stage Bucket Lengths50 Hz 60 Hz

    660 mm (26) 508H mm (20H)

    851 mm (33.5) 660 mm (26)

    1064 mm (42) 762 mm (30)

    1219 mm (48) 851 mm (33.5)

    1016 mm (40)

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    14/20

    Impact of Steam Conditions

    0.0

    1.0

    2.0

    3.0

    4.0

    5.0

    2400 3500Throttle Pressure

    PlantHeatRateImprovemen

    t

    ~ 1.8%

    ~ 1.7%

    ~ 1.6%

    ~ 0.5%HARP Cycle

    Typical 600 MW UnitBaseline :2400 / 1000 F / 1000 F

    ~ 0.8%

    Ultra Super Critical

    (3500 / 1050 F / 1100 F)

    3500 / 1000 F / 1000 F2400/ 1050 F / 1050 F

    Customers, Developers, and OEMs Performing Cost-Benefit Studies

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    15/20

    ProductFocus

    300 350 MW 500 600 MW 750 850 MW

    Code Type D5 D8 & G2 G3

    No. Casings 2 2 or 3 4

    Steam

    ConditionsSubcritical

    Subcriticaland

    Supercritical

    Subcriticaland

    Supercritical

    Fossil Fired Programs

    Focusing on Sweet Spots

    Leveraging CM&U Features Dense Pack Longer LSBs Advanced Sealing

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    16/20

    Product Characteristics: Power Rating: 300 350 MW

    Subcritical Steam Conditions:

    2400 psig / 1000 F / 1000 F Full / Partial Arc {2} Admission

    Opposed Flow Combined HP/IP

    Double Flow LP60 HZ: 2 x 30 / 2 x 33.5 / 2 x 4050 HZ: 2 x 33.5 / 2 x 42 / 2 x 48

    300-350 MW Rating (D-Series)

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    17/20

    Product Characteristics: Power Rating: 500 650 MW

    Subcritical Steam Conditions:

    2400 psig / 1000 F / 1000 FSupercritical Steam Conditions:3500 psig / 1050 F / 1050 F

    Full / Partial Arc {2} Admission

    G2 - Opposed Flow Combined HP/IPG11 Separate HP / Single Flow IP

    Double Flow LP60 HZ: 4 x 30.0 / 4 x 33.550 HZ: 4 x 33.5 / 4 x 42.0

    500 - 650 MW Rating (G2/G11-Series)

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    18/20

    Product Characteristics: Power Rating: 750 850 MW

    Subcritical Steam Conditions:

    2400 psig / 1000 F / 1000 FSupercritical Steam Conditions:3500 psig / 1050 F / 1050 F

    Full / Partial Arc {2} Admission

    Separate HP / Double Flow IP

    Double Flow LP

    60 HZ: 4 x 33.5 / 4 x 42.050 HZ: 4 x 33.5 / 4 x 42.0

    750 - 850 MW Rating (G3-Series)

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    19/20

    STG Product Line

    ST Product Line Overview

    Industrial Steam

    Combined Cycle

    Coal-Fired (Fossil)

    Nuclear

    ST Design Evolution / Enhancements

  • 7/29/2019 Steam+Turbine+Product+Line+101905[1] [Compatibility Mode]

    20/20

    Typical Ratings: Actual Ratings Depend on Steam Conditions,

    Back Pressure and Other Cycle Parameters

    500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600

    N Series ( N1/N1R/N2/N2R)

    Steam Turbine Output (MW)

    Typical Ratings - 50 and 60 Hz

    Nuclear Products

    1000 / 550 /500( PSI / F / F )

    Ongoing Nuclear Steam Turbine Development

    70 / 288 / 288( Bar / C/ C )