Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
N° 139-580 DATE: March 19, 2019
REV. : / - February 27, 2019
Page 1 of 10
TITLE
ATA 64 – FIPS TAIL ROTOR BLADES INSPECTION
REVISION LOG
First issue
An appropriate entry should be made in the aircraft log book upon accomplishment.If ownership of aircraft has changed, please, forward to new owner.
Leonardo S.p.A.Via Giovanni Agusta, 52021017 Cascina Costa di Samarate (VA) ItalyTel.: +39 0331 229111 - Fax: +39 0331 229605/222595
ALERT
SERVICE BULLETIN
S.B. N°139-580 ALERT DATE: March 19, 2019 Page 2 of 10 REVISION: /
1. PLANNING INFORMATION
A. EFFECTIVITY
FIPS TR blades P/N 4G6410A00131, P/N 4G6410A00132 and P/N 4G6410A00133,
installed on AW139 helicopters or kept in stock and with accrued FH.
B. COMPLIANCE
• Within fifty (50) FH from the issue date of this Service Bulletin, for FIPS TR blades
installed on AW139 helicopters.
• Before next installation on the helicopter for FIPS TR blades kept in stock and with
accrued FH.
C. CONCURRENT REQUIREMENTS
N.A.
D. REASON
This Service Bulletin is issued in order to require the inspection of the FIPS TR blades.
E. DESCRIPTION
Following some events of short circuit occurred on the TR blades with heater mat, this
Service Bulletin requires a detailed inspection of the TR blades P/N 4G6410A00131,
P/N 4G6410A00132 and P/N 4G6410A00133 for burn signs and, depending on
findings, the replacement of the part.
This one-off inspection is applicable to the TR blades in service, in order to exclude
not detected arcing damages that may have been caused by a short circuit during
FIPS operations. Moreover, as a further precautionary measure, the inspection is
extended to the parts kept in stock and with accrued FH, with close attention to
possible TR blades stored with the blade root fairing installed.
In addition to this, a conditional inspection has been introduced in AW139 AMPI
Chapter 5 prescribing a detailed inspection of the TR blade in case TAIL ROTOR FAIL
caution is displayed.
S.B. N°139-580 ALERT DATE: March 19, 2019 REVISION: / Page 3 of 10
F. APPROVAL
The technical content of this Service Bulletin is approved under the authority of DOA
nr. EASA.21.J.005. For helicopters registered under other Aviation Authorities, before
applying the Service Bulletin, applicable Aviation Authority approval must be checked
within Leonardo Helicopters customer portal.
EASA states mandatory compliance with inspections, modifications or technical
directives and related time of compliance by means of relevant Airworthiness
Directives.
If an aircraft listed in the effectivity embodies a modification or repair not LHD certified
and affecting the content of this Service Bulletin, it is responsibility of the
Owner/Operator to obtain a formal approval by Aviation Authority having jurisdiction on
the aircraft, for any adaptation necessary before incorporation of the present Service
Bulletin.
G. MANPOWER
To comply with this Service Bulletin three (3) MMH are deemed necessary.
MMH are based on hands-on time and can change with personnel and facilities
available.
H. WEIGHT AND BALANCE
N.A.
I. REFERENCES
1) PUBLICATIONS
DATA MODULE DESCRIPTION PART
DM01 39-A-00-20-00-00A-120A-A Helicopter on ground for a safe maintenance
-
DM02 39-B-64-11-01-00A-520A-A Tail rotor blade assembly - Remove procedure
-
DM03 39-B-64-11-01-00A-720A-A Tail rotor blade assembly - Install procedure
-
DM04 39-B-64-11-06-00A-520A-A Blade root fairing - Remove procedure
-
DM05 39-B-64-11-06-00A-720A-A Blade root fairing - Install procedure
-
2) ACRONYMS
AMDI Aircraft Material Data Information
AMP Aircraft Maintenance Publication
S.B. N°139-580 ALERT DATE: March 19, 2019 Page 4 of 10 REVISION: /
AMPI Aircraft Maintenance Planning Information
DM Data Module
DOA Design Organization Approval
EASA European Aviation Safety Agency
FH Flight Hours
FIPS Full Ice Protection System
ITEP Illustrated Tools and Equipment Publication
LHD Leonardo Helicopter Division
MMH Maintenance Man Hours
MMIR Maintenance Malfunction Information Report
TR Tail Rotor
WRM Warranty Reply Memo
3) ANNEX
N.A.
J. PUBLICATIONS AFFECTED
AW139 AMP
K. SOFTWARE ACCOMPLISHMENT SUMMARY
N.A.
S.B. N°139-580 ALERT DATE: March 19, 2019 REVISION: / Page 5 of 10
2. MATERIAL INFORMATION
A. REQUIRED MATERIALS
1) PARTS
N.A.
2) CONSUMABLES
The following consumable materials, or equivalent, are necessary to accomplish this
Service Bulletin:
# Spec./LHD code number DESCRIPTION Q.TY NOTE PART
1 MIL-S-8660 –
code n. 501229065 Dow Corning (C315) AR (1) -
2 CCC-C-46
code n. 590210190 Cloth, soft lint-free (C011) AR (1) -
Refer to AMDI for the consumable materials required to comply with the AMP DM
referenced in the accomplishment instructions.
3) LOGISTIC MATRIX
N.A.
NOTE
(1) Item to be procured a local supply.
B. SPECIAL TOOLS
The following special tools, or equivalent, are necessary to accomplish this Service
Bulletin:
# P/N DESCRIPTION Q.TY NOTE PART
3 Commercial Light source (fluorescent) / Flashlight 1 (B1) -
4 RMGE-DS-06-2010-RH RH Deck servicing platform (GG-02-00) 1 (B1) -
Refer also to ITEP for the special tools required to comply with the AMP DM
referenced in the accomplishment instructions.
SPECIAL TOOLS NOTE
Item to be procured a local supply. (B1)
S.B. N°139-580 ALERT DATE: March 19, 2019 Page 6 of 10 REVISION: /
C. INDUSTRY SUPPORT INFORMATION
WARRANTY: Owners/Operators who comply with the instructions of this Service
Bulletin no later than the applicable date in the “Compliance” section will be eligible to
receive necessary replacements on free of charge basis, except for Consumable
Materials and Special Tools.
NOTE: Customers who fail to comply with the instructions in this Service Bulletin
before the compliance date are not eligible for the aforementioned special policy.
Please Issue relevant MMIR form to your Warranty Administration Dpt, accompanied
by INSPECTION REPORT and PICTURES of the affected area.
NOTE: the INSPECTION REPORT and PICTURES are mandatory; in case the MMIR
is not accompanied by these documents, it will be rejected.
NOTE: WRM will include RETURN MATERIAL AUTHORIZATION (RMA) number; the
unit removed from the aircraft has to be returned to LHD as per instructions defined
into LHD Information Letter GEN-15-047.
S.B. N°139-580 ALERT DATE: March 19, 2019 REVISION: / Page 7 of 10
3. ACCOMPLISHMENT INSTRUCTIONS
GENERAL NOTES
a) Place an identification tag on all components that
are re-usable, including the attaching hardware that
has been removed to gain access to the
modification area and adequately protect them until
their later re-use.
b) Shape the cables in order to prevent interference
with the structure and the other existing
installations, using, where necessary, suitable
lacing cords.
NOTE
Skip steps 1 and 2 if the TR blade to be inspected is
kept in stock.
1. In accordance with AMP DM 39-A-00-20-00-00A-120A-A, prepare the helicopter on
ground for a safe maintenance. Disconnect the battery, all electrical power sources
and/or the external power supply.
2. Put the Platform (GG-02-00), or an approved alternative, adjacent to the right side of the
fuselage.
NOTE
Perform following step 3 on TR blade kept in stock if
the TR blade has been stored with the blade root
fairing installed.
3. In accordance with AMP DM 39-B-64-11-06-00A-520A-A remove the blade root fairing
from the first TR blade that you must examine.
CAUTION
Do not remove the soldered terminals and Raychem
S1125 adhesive, if present. Soldered terminals and
Raychem S1125 adhesive removal is not required to
perform the inspection.
4. With reference to Figure 1, do a visual inspection of the area below the removed root
fairing for conditions and burn evidence. Use the light source to get an aid during the
inspection.
S.B. N°139-580 ALERT DATE: March 19, 2019 Page 8 of 10 REVISION: /
NOTE
Skip steps 5 thru 9 if the TR blade inspected is kept in
stock.
5. Repeat steps 3 and 4 to inspect all the TR blades.
6. If you find burn evidence, replace the TR blade/blades as described in the following
procedure:
CAUTION
TR blades P/N 4G6410A00133 are interchangeable
and intermixable with TR blades P/N 4G6410A00132.
TR blades P/N 4G6410A00133 are interchangeable
and NOT intermixable with TR blades P/N
4G6410A00131. To replace a TR blade P/N
4G6410A00131 with P/N 4G6410A00133, the
replacement is required in two positions on opposite
blades (opposite blades must be intended blue and
red, yellow and white).
6.1 In accordance with AMP DM 39-B-64-11-01-00A-520A-A remove the affected TR
blade/blades.
6.2 In accordance with AMP DM 39-B-64-11-01-00A-720A-A install the serviceable
TR blade/blades.
CAUTION
Before connecting the slip ring connector to the heating
mat connector, when you install the blade root fairing,
apply Dow Corning (C315) on the connectors (both on
plug and on receptacle) with a paint brush. Make sure
to make a film on inner and outer parts of the
connectors. Clean excess of compound with a soft
cloth (C011).
7. In accordance with AMP DM 39-B-64-11-06-00A-720A-A install the blade root fairing on
the serviceable TR blade/blades.
8. Remove the platform from the right side of the fuselage.
9. Return the helicopter to flight configuration and record for compliance with this Service
Bulletin on the helicopter logbook.
10. Send the defective TR blade/blades to LHD.
S.B. N°139-580 ALERT DATE: March 19, 2019 REVISION: / Page 9 of 10
11. Send the attached compliance form to the following mail box:
As an alternative, gain access to My Communications section on Leonardo WebPortal
and compile the “Service Bulletin Application Communication”.
Remarks:
Information:
SERVICE BULLETIN COMPLIANCE FORM Date:
Number:
Revision:
Please send to the following address:
Telephone:
Fax:
B.T. Compliance Date:
Customer Name and Address:
Helicopter Model S/N Total Number Total Hours T.S.O.
LEONARDO S.p.A.CUSTOMER SUPPORT & SERVICES - ITALY
PRODUCT SUPPORT ENGINEERING & LICENSES DEPT. Via Giovanni Agusta, 52021017 Cascina Costa di Samarate (VA) - ITALY
Tel.: +39 0331 225036 Fax: +39 0331 225988
We request your cooperation in filling this form, in order to keep out statistical data relevant to aircraft configuration up-to-date. The form should be filled in allits parts and sent to the above address or you can communicate the application also via Technical Bulletin Application Communication Section placed in Leonardo AW Customer Portal - MyCommunications Area. We thank you beforehand for the information given.