12
Figure 2 -N H A ctive P ublic W aterSystems 0 500 1000 1500 2000 2500 3000 2007 2008 2009 Num berof System s CW S N TN C NC TO TA L 721 451 1244 2416 712 447 1256 2415 709 444 1260 2413

RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing 30-60 days test duration Up to 5 medias / columns Equipment available

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Figure 2 - NH Active Public Water Systems

0

500

1000

1500

2000

2500

3000

2007 2008 2009

Num

ber o

f Sys

tem

s CWS

NTNC

NC

TOTAL721

451

1244

2416

712

447

1256

2415

709

444

1260

2413

Page 2: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

ARSENIC STRATEGIES

TREATMENT~74%

BLENDING ~23%

STILL >10 PPB~3%

Page 3: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Figure 2 - NH ARSENIC TREATMENT TECHNOLOGIES

82

31

22

1

9

6

0 20 40 60 80 100

New Adsorption medias

Iron-Arsenic filters

Anion Exchange

Activated Alumina

POU Reverse Osmosis

POU Adsorption

Number of Systems

Total = 151CWS and NT/NC

March 2009

Page 4: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available
Page 5: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Adsorption Treatment Examples

0

10

20

30

40

50

60

70

80

Q106 Q206 Q306 Q406 Q107 Q207 Q307 Q407 Q108 Q208 Q308 Q408 Q109

Tre

ated

wat

er A

s, p

pb

12345678910

New MCL = 10 ppb RAA

Page 6: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Adsorptive Media Bedlife Performance

37,600

20,000 19,000

58,500

12,100

83,300

36,700

20,000

-

10,000

20,000

30,000

40,000

50,000

60,000

70,000

80,000

90,000

100,000

A B C D E F G H

Bed

Vo

lum

es o

f W

ater

Tre

ated

to

10

pp

b b

reak

thro

ug

h

1 BV = CF media x 7.48 gal/CFExample:1.5 million gallons treated by10 CF arsenic media= 20,000 BV bedlife

Page 7: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

RSSCT Adsorptive Media CompareRSSCT Adsorptive Media CompareRSSCT = Rapid Small Scale Column TestingRSSCT = Rapid Small Scale Column Testing

30-60 days test duration30-60 days test duration

Up to 5 medias / columnsUp to 5 medias / columns

Equipment available free Equipment available free from DES and UNH TACfrom DES and UNH TAC

PWS collects and pays PWS collects and pays sample analysessample analyses

Daily inspection requiredDaily inspection required

Page 8: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Anion ExchangeAnion Exchange

Simplest onsite regenerationSimplest onsite regeneration

Must manage alkalinity / corrosionMust manage alkalinity / corrosion

Dumping happens!Dumping happens!

No As III removalNo As III removal

Page 9: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Anion Exchange Treatment Examples

0

10

20

30

40

50

60

70

80

Q106 Q206 Q306 Q406 Q107 Q207 Q307 Q407 Q108 Q208 Q308 Q408 Q109

Tre

ated

wat

er A

s, p

pb

1

2

3

4

5

6

7

New MCL = 10 ppb RAA

Page 10: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Iron-Arsenic Oxidation Filtration Iron-Arsenic Oxidation Filtration ((aka greensandaka greensand))

20:1 Iron to As ratio 20:1 Iron to As ratio

pH ≤7.5pH ≤7.5

Chlorine or Chlorine or Permanganate feedPermanganate feed

High Backwash Rate High Backwash Rate Pyrolusite mediasPyrolusite medias

Backwash filter or Backwash filter or common septic tankcommon septic tank

Page 11: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

Iron-Arsenic Oxidation-Filtration Examples

0

10

20

30

40

50

60

70

80

Q106 Q206 Q306 Q406 Q107 Q207 Q307 Q407 Q108 Q208 Q308 Q408 Q109

Trea

ted

wat

er A

s, p

pb

1

2

3

4

5

6

7

New MCL = 10 ppb RAA

Page 12: RSSCT Adsorptive Media Compare RSSCT = Rapid Small Scale Column Testing  30-60 days test duration  Up to 5 medias / columns  Equipment available

www.des.nh.govwww.des.nh.gov A to Z list A to Z list

– ““A” = Arsenic drinking water pageA” = Arsenic drinking water page– ““R” = Radon in Air pageR” = Radon in Air page– ““R” = Rads drinking water pageR” = Rads drinking water page– ““S” = Small PWS Help CenterS” = Small PWS Help Center– ““U” = Uranium / rads pageU” = Uranium / rads page

Quick Links “Publications/Factsheets”Quick Links “Publications/Factsheets”

[email protected]@des.nh.gov, 271-3108, 271-3108