5
CATALOG P28-S7-Cover.pub The information contained herein is copyright protected and is the sole property of DTL Technologies, LP, and may not be reproduced without expressed written permission, it may be changed without notice. All rights reserved, DTL Technologies, LP. Houston, Texas 713-932-9119 RIGID CONDUIT MANIFOLDS, FAIL-SAFE ASSIST CIRCUITS, EDS SYSTEMS, MULTI-PILOT CONNECTORS DTL can manufacture manifolds, control systems, and add-on circuit hardware. Accumulator manifolds, supply headers, and special control circuits such as Choke and Kill Fail-Safe circuits and Rigid Conduit Manifolds have all been man- ufactured by DTL Technologies. S S YSTEMS YSTEMS / M / M ANIFOLDS ANIFOLDS S S YSTEMS YSTEMS / M / M ANIFOLDS ANIFOLDS S S YSTEMS YSTEMS / M / M ANIFOLDS ANIFOLDS

RIGID CONDUIT MANIFOLDS, FAIL SYSTEMS, … › wp-content › uploads › Additional-Products...choke or kill valve is hydrau-lically opened. When the pilot signal is removed, the

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RIGID CONDUIT MANIFOLDS, FAIL SYSTEMS, … › wp-content › uploads › Additional-Products...choke or kill valve is hydrau-lically opened. When the pilot signal is removed, the

CA

TA

LO

G

P28-S

7-C

over.

pub

The information contained herein is copyright protected and is the sole property of DTL Technologies, LP, and may not be reproduced without expressed written permission, it may be changed without notice. All rights reserved, DTL Technologies, LP. Houston, Texas 713-932-9119

RIGID CONDUIT MANIFOLDS, FAIL-SAFE ASSIST CIRCUITS, EDS SYSTEMS, MULTI-PILOT CONNECTORS

DTL can manufacture manifolds, control systems, and add-on circuit hardware. Accumulator manifolds, supply headers, and special control circuits such as Choke and Kill Fail-Safe circuits and Rigid Conduit Manifolds have all been man-ufactured by DTL Technologies.

SSY

ST

EM

SY

ST

EM

S /

M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

Page 2: RIGID CONDUIT MANIFOLDS, FAIL SYSTEMS, … › wp-content › uploads › Additional-Products...choke or kill valve is hydrau-lically opened. When the pilot signal is removed, the

CA

TA

LO

G

P30-S

7.p

ub

The information contained herein is copyright protected and is the sole property of DTL Technologies, LP, and may not be reproduced without expressed written permission, it may be changed without notice. All rights reserved, DTL Technologies, LP. Houston, Texas 713-932-9119

RIGID CONDUIT VALVE ASSEMBLY

This Multi-Valve Assembly was created to operate as a rigid conduit manifold. This configuration will allow control of the rigid conduit supply to the yellow and blue pods. This design improvement was used to convert the main con-trol valves from slide valves to SPMs. Secondary focus was to reduce plumb-ing clutter on the stack by condensing the circuit into a modular package. Features include conduit dump, filter assembly, and pilot controls to flow sup-ply and POD pressure dump.

SSY

ST

EM

SY

ST

EM

S /

M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

Page 3: RIGID CONDUIT MANIFOLDS, FAIL SYSTEMS, … › wp-content › uploads › Additional-Products...choke or kill valve is hydrau-lically opened. When the pilot signal is removed, the

CA

TA

LO

G

P31-S

7.p

ub

The information contained herein is copyright protected and is the sole property of DTL Technologies, LP, and may not be reproduced without expressed written permission, it may be changed without notice. All rights reserved, DTL Technologies, LP. Houston, Texas 713-932-9119

RIGID CONDUIT VALVE ASSEMBLY

This Rigid Conduit Assembly is designed to be mounted on a flat surface / plate. The bolt pattern for mounting and schematic diagram is shown in the figure below.

SPECIFICATIONS

Maximum working pressure: 3000 PSI

Maximum proof pressure: 4,500 PSI

Assembly weight: 425 lbs

Conduit Manifold Inlet & Outlet Connections : 1-1/2” Code 62 Seal-

Sub W/Adaptors to JIC as shown.

Pilot connections: 1/4 NPT

Built-In filter: 40 Micron

SSY

ST

EM

SY

ST

EM

S /

M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

Page 4: RIGID CONDUIT MANIFOLDS, FAIL SYSTEMS, … › wp-content › uploads › Additional-Products...choke or kill valve is hydrau-lically opened. When the pilot signal is removed, the

CA

TA

LO

G

P32-S

7.p

ub

The information contained herein is copyright protected and is the sole property of DTL Technologies, LP, and may not be reproduced without expressed written permission, it may be changed without notice. All rights reserved, DTL Technologies, LP. Houston, Texas 713-932-9119

FAIL-SAFE ASSIST CIRCUITS

Fail-Safe Assist Circuits are

added to Choke and Kill valves

to assist in positive closure of

these types of valves, which

were originally designed with a

spring-to-close actuator. The

fail-safe circuit supply pressure

is captured in an accumulator

from the pilot line when the

choke or kill valve is hydrau-

lically opened. When the pilot

signal is removed, the accumu-

lated pressure is released to

close the valve along with the

spring actuator. An orifice can

be installed between the two

control valves to sequence the

valves when both pilots are re-

leased simultaneously.

SSY

ST

EM

SY

ST

EM

S /

M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

Page 5: RIGID CONDUIT MANIFOLDS, FAIL SYSTEMS, … › wp-content › uploads › Additional-Products...choke or kill valve is hydrau-lically opened. When the pilot signal is removed, the

CA

TA

LO

G

P33-S

7.p

ub

The information contained herein is copyright protected and is the sole property of DTL Technologies, LP, and may not be reproduced without expressed written permission, it may be changed without notice. All rights reserved, DTL Technologies, LP. Houston, Texas 713-932-9119

SKID-MOUNTED REGULATOR / SPM

SPECIFICATIONS

Maximum working pressure: 5,000 PSI Regulator outlet adjustable to: 1,000 - 4,500 PSI Assembly weight: 175 lbs Regulator & SPM manifold inlet & outlet connections: 1” Code 62 Seal-Sub

This Multi-Valve Assembly was designed to add a 3000 PSI circuit from a 5K PSI supply manifold. The configuration will allow reduction of pressure from the 5000 PSI supply to 3000 PSI downstream from the regulator. An SPM control valve (N.C. 3W-2P) was used to control supply to the new circuit.

SSY

ST

EM

SY

ST

EM

S /

M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS

SS

YS

TE

MS

YS

TE

MS

/ M/ M

AN

IFO

LD

SA

NIF

OL

DS