12
© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com USB 3.1 Type-C solutions from Texas Instruments and Würth Elektronik Speaker: Frank Puhane Würth Elektronik eiSos GmbH & Co. KG

Common Mode Choke

Embed Size (px)

Citation preview

Page 1: Common Mode Choke

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

USB 3.1 Type-C solutions from Texas Instruments and Würth Elektronik

Speaker:Frank Puhane

Würth Elektronik eiSosGmbH & Co. KG

Page 2: Common Mode Choke

117.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• For signal integrity it is recommended to not filter the first four harmonics • Cut off frequency should be greater than the fourth harmonic

Am

plitu

de

Am

plitu

de

Am

plitu

de

Filte

r gai

n

Time [ms] Frequency [GHz]

Time [ms]Frequency [GHz]

Page 3: Common Mode Choke

217.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• Signal has a NRZ-coding and data rate is 1Gbit/s• Filter with two SMD-Ferrite => WE-CBF HF• Transmission line without filter (left) and with SMD-Ferrites WE-CBF HF (right)

Page 4: Common Mode Choke

317.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• Inserted components changes the impedance of the system• Causes unwanted reflexion

• Solution: insert components without differential impedance

• Signal has a NRZ-coding and data rate 2,5Gbit/s• Reflexion because of impedance mismatching

Page 5: Common Mode Choke

417.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• Comparison between WE-CNSW (black) and WE-CNSW HF (red)

• Same impedance in common and differential mode

Page 6: Common Mode Choke

517.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• S-Parameter measurement• S-Parameter with 4-Port measurement

Page 7: Common Mode Choke

617.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• Measurement setup (simulation with Qucs)

[Hz] [Hz]

Page 8: Common Mode Choke

717.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

• Comparison between WE-CNSW (left) and WE-CNSW HF (right)

Common Mode Choke

[Hz] [Hz]

Page 9: Common Mode Choke

817.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• Data rate: 2,5 Gbit/s • Difference in signal integrity is not so big• Harmonics of the signal are not filtered

WE-CNSW WE-CNSW HF

Page 10: Common Mode Choke

917.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• Data rate: 5 Gbit/s• Difference in the signal because of the differential impedance

WE-CNSW WE-CNSW HF

Page 11: Common Mode Choke

1017.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke

• Data rate: 7 Gbit/s• WE-CNSW filters the fundamental frequency of the signal• WE-CNSW HF filters only the high frequency harmonics of the signal

WE-CNSW WE-CNSW HF

Page 12: Common Mode Choke

1117.08.2016 | Wurth Elektronik eiSos | Public | Common Mode Chokes

© All rights reserved by Wurth Electronics, also in the event of industrial property rights. All rights of disposal such as copying and redistribution rights with us. www.we-online.com

Common Mode Choke