16
GRUNDFOS DATA BOOKLET Renewable Solar Inverter, RSI Renewable Solar Inverter for large solar powered systems 3 - 9.2 kW

Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Embed Size (px)

Citation preview

Page 1: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

GRUNDFOS DATA BOOKLET

Renewable Solar Inverter, RSIRenewable Solar Inverter for large solar powered systems3 - 9.2 kW

Page 2: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Ta

ble

of c

on

ten

ts

2

Renewable Solar Inverter, RSI

1. Performance range 3Performance range 3

2. Applications 4

3. Product introduction 5Type key 5Features and benefits 5

4. System components 6SP submersible pump 6Renewable Solar Inverter (RSI) 6Circuit breaker, AC 7Solar panel 7Dry-running switch 7Junction box components kit, DC 7Level switch (optional) 7

5. Technical data 8RSI Renewable Solar Inverter 8Circuit breaker, DC 8Surge protection, DC 8

6. Product number 9RSI Renewable Solar Inverter 9Junction box components kit 9Dry-running switch 9Level switch (optional) 9

7. Appendix 10

8. Further product information 11WebCAPS 11WinCAPS 12GO CAPS 13

Page 3: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Pe

rfo

rma

nc

e r

an

ge

Renewable Solar Inverter, RSI 1

1. Performance range

Performance range

Fig. 1 Performance range

TM

05

75

94

12

13

0.50.5 11 2 3 4 5 6 8 1010 15 20 30 40 50 60 80 100100 150 200Q [m³/h]

4

10

2020

40

60

80

100100

200

400

600

H[m]

40

60

80

100

200

400

600

800

1000

2000

4000

6000

p[kPa]

0.2 0.4 0.6 0.8 1 2 4 6 8 10 20 Q [l/s]

X2 x SQ FLEX

XSQ FLEX

SP (+ RSI3000)

SP (+ RSI4000)

SP (+ RSI5500)

SP (+ RSI9200)

3

Page 4: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Ap

plic

atio

ns

4

Renewable Solar Inverter, RSI2

2. Applications

The Grundfos Renewable Solar Inverter (RSI) system is designed for continuous as well as intermittent operation. The system is especially suitable for supplying water in applications such as:

• villages, schools, hospitals, and single-family houses

• farms and ranches, including watering of livestock and irrigation of crops and greenhouses

• game parks and game farms.

The Renewable Solar Inverter (RSI) system can be used in any existing SP pump application, thus providing a very wide range of applications. The only difference is that you use solar panels as the power supply.

Application exampleThe water production of an RSI system depends on the availability of solar power. The result is excess water production in the early afternoon and insufficient water production in the morning and late afternoon. A system equipped with a storage water tank enables stable water supply throughout the day.

One junction box components kit is required for each set of inputs on the DC side. A junction box components kit contains a circuit breaker and surge protection to ensure maximum safety to the user as well as the system.

Install the inverter in an indoor environment/cabinet with sufficient ventilation.

Fig. 2 RSI application example

TM

05

44

49

23

12

1 Solar panel2 Mounting structure3 Circuit Breaker DC4 Surge Protection DC5 Renewables Solar Inverter6 SP pump7 Cable8 Submersible drop cable

9 Circuit breaker AC

10 Dry running sensor

11 Pipe

12 Water tower/tank

13 Level switch

If the distance between the PV and the inverter is more than 10m,it is necessary to add an extra surge protection closer to the PV side.

*)

*)

9

3

1

2

8

6

7

3

4

4

5

11

12

13

10

DATARUNPROG

MODESTOP

ENTER

RUN STOP FAULT NORMAL STOPEXTERNAL

WARNING:

For indoor installation only.

Only to be serviced by qualified staff.

Excessive input voltage will damage the equipment.

Ensure proper wiring and grounding ( earth ).

Distributed by

ELECTRIC SHOCK HAZARD

DANGEROUS VOLTAGES AND CURRENTS

RSI 3000

1 Solar panel

2 Mounting structure

3 Circuit breaker DC

4 Surge protection DC*

5 Renewable Solar Inverter

6 SP pump

7 Cable

8 Submersible drop cable

9 Circuit breaker AC

10 Dry-running switch

11 Pipe

12 Water tower/tank

13 Level switch

* If the distance between the solar panel and the inverter is more than 10 m, it is necessary to add extra surge protection closer to the solar panel.

Page 5: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Pro

du

ct

intr

od

uc

tio

n

Renewable Solar Inverter, RSI 3

3. Product introduction

Type key

Features and benefits

Maximum power point tracking (MPPT)The inverter has built-in electronics with MPPT function. The inverter will continuously optimise according to the DC input power available.

Overvoltage and undervoltage protectionOvervoltage and undervoltage may occur in case of faulty installation. The inverter will cut out power connection to the motor if the voltage falls outside the allowed voltage limits. The inverter will stay in the same fault mode with the error code displayed on the inverter until the inverter is being reset.

Overload protectionOverload may occur if the maximum allowed frequency is set too high or a wrong pump is used. The inverter will cut out power connection to the motor if overload occurs. The inverter will stay in the same fault mode with the error code displayed on the inverter until the inverter is being reset.

Overcurrent protectionOvercurrent may occur if, for example, a wrong cable size is used. The inverter will cut out power connection to the motor if the current falls outside the allowed current limits. The inverter will stay in the same fault mode with the error code displayed on the inverter until the inverter is being reset.

Note: For the protection to function properly, the actual current value must be adjusted according to the maximum current attained at the maximum frequency shortly after the system started operation.

Overtemperature protectionOvertemperature of the inverter may occur if appropriate ventilation is not available or the ambient temperature is too high. The inverter will cut out power connection to the motor if overtemperature occurs in the inverter. The inverter will stay in the same fault mode with the error code displayed on the inverter until the inverter is being reset.

Note: The inverter does not detect motor temperature or protect the motor against overtemperature.

No-load protectionNo-load situation of the inverter may occur if, for example, the cable to the motor is broken. The inverter will cut out power connection to the motor if no-load occurs. The inverter will stay in the same fault mode with the error code displayed on the inverter until the inverter is being reset.

Note: For the protection to function properly, please check the RSI installation and operating instructions carefully during the operation.

Operation history memoryThe inverter will store historical operating data. The data can be retrieved through the menu on the inverter. Data can be retrieved for every minute of operation up to two years back.

Code Example RSI 3000

RSI = Renewable Solar Inverter

3000 = Max. power input to motor [W]

5

Page 6: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Sy

ste

m c

om

po

ne

nts

6

Renewable Solar Inverter, RSI4

4. System components

An RSI system consists of a standard SP pump, a Renewable Solar Inverter (RSI), ranging from 3 to 9.2 kW, and accessories. The RSI system is configured especially to run with Grundfos SP pumps.

The RSI system components are:

• SP submersible pump, 50 Hz

• Renewable Solar Inverter (RSI)

• junction box components kit, DC

– circuit breaker, DC

– surge protection, DC

• circuit breaker, AC

• solar panel

• dry-running switch

• level switch (optional).

SP submersible pumpThe SP pump is available as complete unit or as separate motor or pump.

SP pump selection for RSI system:

• SP submersible pump, 50 Hz

• power supply: 3 x 380 VAC.

• Material: 1.4301, 1.4401 or 1.4539.

Standard SP pumps can only be operated by AC power supply. Do not connect the SP pump directly to solar panel.

Fig. 3 SP pumps

Renewable Solar Inverter (RSI)RSI is an off-grid solar inverter converting the DC power output from the solar panel to AC power supply for SP pump operation.

The RSI inverter has a built-in MPPT software, protection features as well as operating history memory, see Features and benefits. The maximum power delivered to the motor ranges from 3 to 9.2 kW.

The RSI inverter has either two sets or four sets of power inputs. Each set of inputs has a limit of maximum 750 V and 15 A from the solar panel.

Indoor installation requires ventilation.

Fig. 4 RSI inverter

The RSI inverter combined with controller and protection units can be used for:

• maximum power point tracking (MPPT)

• DC to three-phase AC conversion

• connection to dry-running switch

• connection to level switch

• operating history inquiry.

Fig. 5 Dimensions [mm], RSI inverter

TM

05

77

29

15

13

TM

05

75

79

12

13

WarningCUE is not suitable for off-grid solar system use.

TM

05

75

80

12

13

DATARUN

PROG

MODESTOP

ENTER

RUN STOP FAULT NORMAL STOPEXTERNAL

WARNING:

For indoor installation only.

Only to be serviced by qualified staff.

Excessive input voltage will damage the equipment.

Ensure proper wiring and grounding ( earth ).

Distributed by

ELECTRIC SHOCK HAZARD

DANGEROUS VOLTAGES AND CURRENTS

RSI 3000

2-ø6

200

167140.5235

250

310

295

DATARUN PROG

MODESTOP ENTER

RUN STOP FAULT NORMAL STOPEXTERNAL

WARNING:

For indoor installation only.

Only to be serviced by qualified staf.

Excessive input voltage will damage the equipment.

Ensure proper wiring and grounding ( earth ).

Distributed by

ELECTRIC SHOCK HAZARD

DANGEROUS VOLTAGES AND CURRENTS

RSI 3000

Page 7: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Sy

ste

m c

om

po

ne

nts

Renewable Solar Inverter, RSI 4

Circuit breaker, ACAn AC circuit breaker is a standard circuit breaker used for normal three-phase power connection.

Solar panelThe solar panel offered by Grundfos is specially selected for Grundfos renewable products.

All Grundfos solar panels are equipped with plugs and sockets enabling easy connection. The number of solar panels required depends on the water quantity required, water pressure required and installation location.

Dry-running switchThe dry-running switch is recommended for all submersible pump operation. The switch can prevent the risk of the pump operating in a dry well, which could result in damage of the pump.

Junction box components kit, DC

Circuit breaker, DC

Fig. 6 Circuit breaker

The DC circuit breaker is suitable for the solar-powered RSI system.

The circuit breaker enables manual starting and stopping of the system. At least one DC circuit breaker is required for each set of inputs to the RSI inverter. We recommend to install two DC circuit breakers for each set of inputs if the distance between the solar panel and the inverter is more than 10 m. To install the circuit breaker, a torx screwdriver, Tx8, is needed.

Fig. 7 Dimensions [mm], circuit breaker

Surge protection, DC

Fig. 8 Surge protection

The DC surge protection is suitable for the solar-powered RSI system.

The surge protection gives a very safe and reliable protection of the system by having a quick response. At least one DC surge protection is required for each set of inputs to the RSI inverter. We recommend to install two DC surge protections for each set of inputs if the distance between the solar panel and the inverter is more than 10 m.

Fig. 9 Dimensions [mm], surge protection

Level switch (optional)A level switch serves as a start/stop control that depends on the water level in the storage water tank.

TM

05

75

81

12

13

TM

05

75

85

12

13

I ON

O O

FF

150

95 95

34.5

TM

05

75

82

12

13

TM

05

75

86

12

13

43.558

64.885 45

53.4

LL

7

Page 8: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Te

ch

nic

al d

ata

8

Renewable Solar Inverter, RSI5

5. Technical data

RSI Renewable Solar Inverter

Circuit breaker, DC

Surge protection, DC

Description RSI 3000 RSI 4000 RSI 5500 RSI 9200

Min. ambient temperature [°C] -10 -10 -10 -10

Max. ambient temperature [°C] 50 50 50 50

Max. relative humidity [%] 95 95 95 95

Max. P1, motor [kW] 3 4 5.5 9.2

Min. recommended MPP voltage [V] 530 530 530 530

Max. recommended MPP voltage [V] 600 600 600 600

Max. DC input voltage [V] 750 750 750 750

Max. DC input current per set [A] 15 15 15 15

Min. frequency [Hz] 30 30 30 30

Max. frequency [Hz] 53 53 53 53

Phase 3 3 3 3

Rated output voltage, AC [V] 380 380 380 380

Max. output current, AC [V] 9 13 18 24

Enclosure class IP41 IP41 IP41 IP41

Net weight [kg] 7.2 7.3 7.7 8.2

Gross weight [kg] 9.5 9.6 10 10.5

Length [mm] 425 425 425 425

Width [mm] 325 325 325 325

Height [mm] 285 285 285 285

Voltage, DC [V] 1000

Current [A] 16

Weight [kg] 1.05

Marking IEC 60047

Voltage, DC [V] 1000

Current [A] 40,000

Weight [kg] 0.375

Marking CE

Page 9: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Pro

du

ct

nu

mb

er

Renewable Solar Inverter, RSI 6

6. Product number

RSI Renewable Solar Inverter

Junction box components kit

Dry-running switch

Level switch (optional)

High water level: Contact is closed.

Low water level: Contact is open.

RSI inverter Max. P1 to motor Product number

RSI 3000 3 kW 98449972

RSI 4000 4 kW 98449973

RSI 5500 5.5 kW 98449975

RSI 9200 9.2 kW 98449977

Description Product number

Junction box components kit, DC 98298572

Circuit breaker, DC 98341686

Surge protection, DC 98341687

TM

05

74

57

10

13

Description Product number

Dry-running switch 98347579

TM

02

24

07

42

01

Description Product number

Level switch 010748

9

Page 10: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Ap

pe

nd

ix

10

Renewable Solar Inverter, RSI7

7. Appendix

The table below shows the recommended cable size (diameter in mm2) to be used between solar panel and RSI inverter in order to keep the power loss lower than 2 % at 20 °C.

Current in cable

[A]

Distance between solar panel and RSI

30 m 60 m 90 m 120 m 150 m 180 m 210 m 240 m 270 m 300 m 330 m 360 m 390 m

Recommended cable size [mm2]

3 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 4 4 6

6 1.5 1.5 1.5 2.5 2.5 4 4 4 6 6 6 6 10

9 1.5 1.5 2.5 4 4 6 6 6 10 10 10 10 16

12 1.5 2.5 4 4 6 6 10 10 10 10 16 16 16

15 1.5 2.5 4 6 6 10 10 10 16 16 16 16 16

Page 11: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Fu

rth

er

pro

du

ct

info

rma

tio

n

Renewable Solar Inverter, RSI 8

8. Further product information

WebCAPS

WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.

WebCAPS contains detailed information on more than 220,000 Grundfos products in more than 30 languages.

Information in WebCAPS is divided into six sections:

• Catalogue

• Literature

• Service

• Sizing

• Replacement

• CAD drawings.

Catalogue

Based on fields of application and pump types, this section contains the following:• technical data• curves (QH, Eta, P1, P2, etc.) which can be adapted to the

density and viscosity of the pumped liquid and show the number of pumps in operation

• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.

Literature

This section contains all the latest documents of a given pump, such as• data booklets• installation and operating instructions• service documentation, such as Service kit catalogue and

Service kit instructions• quick guides• product brochures.

Service

This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps.Furthermore, the section contains service videos showing you how to replace service parts.

11

Page 12: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Fu

rthe

r pro

du

ct in

form

atio

n

12

Renewable Solar Inverter, RSI8

WinCAPS

Fig. 10 WinCAPS DVD

Sizing

This section is based on different fields of application and installation examples and gives easy step-by-step instructions in how to size a product:• Select the most suitable and efficient pump for your

installation.• Carry out advanced calculations based on energy,

consumption, payback periods, load profiles, life cycle costs, etc.

• Analyse your selected pump via the built-in life cycle cost tool.• Determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section, it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:• .dxf, wireframe drawings• .dwg, wireframe drawings.

3-dimensional drawings:• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.

WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 220,000 Grundfos products in more than 30 languages.

The program contains the same features and functions as WebCAPS, but is an ideal solution if no internet connection is available.

WinCAPS is available on DVD and updated once a year.

0 1

Page 13: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

Fu

rth

er

pro

du

ct

info

rma

tio

n

Renewable Solar Inverter, RSI 8

GO CAPS

Mobile solution for professionals on the GO!

CAPS functionality on the mobile workplace.

Subject to alterations.

13

Page 14: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

14

Page 15: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

15

Page 16: Renewable Solar Inverter, RSI - TRITEC-Intervento · Renewable Solar Inverter, RSI ... RSI Renewable Solar Inverter 8 Circuit breaker, DC 8 Surge protection, DC 8 6. Product number

GRUNDFOS A/S DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00www.grundfos.com

98462976 0413

ECM: 1112744 Th

e n

am

e G

run

dfo

s, t

he

Gru

nd

fos

log

o,

an

d b

e t

hin

k i

nn

ov

ate

are

re

gis

tere

d t

rad

em

ark

s o

wn

ed

by

Gru

nd

fos

Ho

ldin

g A

/S o

r G

run

dfo

s A

/S,

De

nm

ark

. A

ll ri

gh

ts r

ese

rve

d w

orl

dw

ide

Co

pyr

igh

t G

run

dfo

s H

old

ing

A/S