REMKO RKL 290 / RKL 350 Portable Air Conditioner

Edition GB – T12

Page 2: REMKO RKL 290 / RKL 350 Portable Air Conditioner
Page 3: REMKO RKL 290 / RKL 350 Portable Air Conditioner

Always keep these operating instructions near or on the unit.

Read these instructions carefully before setting up /operating the unit!!

Our guarantee becomes null and void if the unit is used, set up

or maintained improperly, or if modifications are made to the

supplied unit without our prior consent.

Subject to alterations!

Portable Air Conditioner

REMKO RKL 290 / REMKO RKL 350

Operating Instructions

Contents Page Safety Instructions 4

Transport and Packaging 4

Description of Device 5

Operation 5

Prior to Initial Operation 8

Initial Operation 9

Shutting Down the Unit 9

Maintenance and Service 10

Cleaning the Filter 10

Contents Page

Wiring Diagram 10

Troubleshooting 11

Technical Data 12

Customer Service and Guarantee 12

Environment and Recycling 14

Exploded View 12

Spare Part List 13

Installation of the Wall Lead-through 15

Page 4: REMKO RKL 290 / RKL 350 Portable Air Conditioner

4

Safety Instructions Extensive tests have been conducted on the material, functionality and quality of the REMKO portable air conditioner to ensure that it is a high-performance unit with a long service life.

Hazards may nevertheless arise if the unit is used by persons not familiar with its operation or if the unit is not used for its intended purpose.

Please make sure to follow these instructions:

The unit is not suitable for outdoor operation.

Do not set up or operate the unit in rooms suscepti-ble to explosions.

Ensure that the unit is set up at a safe distance from flammable materials.

Do not set up or operate the unit if the atmosphere is contaminated by oil, sulphur or salt.

Do not set the unit up near curtains or drapes. Minimum distance of 50 cm.

Ensure that the air intake and outlet openings are always clear of foreign objects.

Ensure that the air conditioner is securely placed on a level surface.

The unit may only be operated in an upright posi-tion.

Do not insert any foreign objects into the air intake or outlet openings.

Do not place any heavy or warm objects on top of the unit.

Do not expose the unit to direct streams of water.

Operate the unit only within its permissible operat-ing ranges. Pay attention to the surrounding temperatures.

This unit may only be connected to a correctly in-stalled, grounded and fused plug socket. 230V / 50Hz, fuse 10A.

When unplugging the unit, do not pull the power cable too forcefully or bend it too much. This may result in damage to the cable!

Do not move the unit while in operation. Wait at least 5 minutes before starting the unit after it has been moved. This protects the unit from damage.

Switch the unit off by pressing the “Power” button. Do not switch the unit off by unplugging the power cord.

Do not transport the unit during operation.

Do not place the unit on its side.

Protect all electrical cables from being damaged, for example, by animals.

Make sure that all extension cables are suitable in terms of capacity, length and intended use.

Do not lay any lines under carpets.

Never operate the unit without the air filter!

Never aim the air current directly at people!

Never open the unit housing! This may cause an electrical shock.

Work on the cooling system and on the electrical equipment may only be performed by an authorised service centre.

Transport and Packaging All units are subject to continuous quality control and are carefully packaged before being sent.

The device is shipped in a stable transport box made of cardboard. Please examine the unit when it is deliv-ered.

Make note of any damage or missing parts on the ship-ping bill and inform the shipping company and your contract partner. No liability is assumed for subsequent claims.

Please observe the following for transport:

Before transporting the unit, switch it off on the control panel and unplug the power cable.

The unit may only be transported in an upright posi-tion.

The unit is equipped with wheels and two handles to makes transport easier.

Excess condensation is collected in the internal tank of the unit. We recommend removing this water prior to transport via the drain at the back of the unit.

Operation/handling which does not comply with these instructions is prohibited! In cases of non-compliance, we assume no liability and the guarantee becomes null and void.

Page 5: REMKO RKL 290 / RKL 350 Portable Air Conditioner

5

The unit’s primary function is to air-condition rooms. It also filters and dehumidifies the air, thus creating a comfortable climate in the room.

In “Fan” mode, the unit can also be used to circulate air with no cooling effect.

The units operates fully-automatically and offers a range of other options thanks to its microprocessor con-trol. For example, it can be automatically switched off and on at a preset time via the timer function.

The unit is comfortably operated via the control panel on the indoor unit or via the infrared remote control that comes with it.

Description of Device The RKL 290-350 air conditioner comes with an infra-red remote control and an air outlet hose with a flat nozzle.

Operation Prior to putting the unit into operation, ensure that all safety instructions have been observed.

Please note that the unit operates most efficiently and most comfortably when put into operation before the hottest part of the day, e.g. the morning.

The selected target temperature should be 4 to 7°C be-low the outside temperature. It should never be lower because the room temperature would feel too cold when coming from a non-air-conditioned room and peo-ple may catch cold.

The selected target temperature does not affect the performance of the unit! This means that when tem-peratures in the room are high, it is not practical to ad-just the unit to the lowest possible target temperature.

The unit has been designed for automatic, universal, smooth air dehumidification. Its compact dimensions make it easy to transport and set up in all rooms.

The unit meets the basic safety and health require-ments found in the relevant EU regulations. It is safe and easy to operate.

Functional principle

The portable air conditioner cools the air in the room by extracting the heat from it. The heat absorbed is ex-pelled to the outside via the exhaust hose and the cooled air is resupplied to the room where the unit is in operation via a fan.

Condensation that accumulates drips from the evapora-tor onto the hot condenser where it condenses and is then transported via the air outlet hose to the outside. Excess condensation drips from the condenser into a collection tray and is resupplied to the condenser by means of a rotating wheel with blades, where it evapo-rates and is then expelled with the outgoing air current.

Control panel

Air directing plate fins

IR receiver

Transport wheels

Recessed grip

Condensation drain with plug

Air outlet hose

Air intake circulation

Air outlet exhaust

The environmentally-friendly refrigerant, R 410A, trans-ports the absorbed heat within the closed-loop refriger-ant cycle.

Cool circulating air in the room

Warm air expel-led to the outsi-de

Evaporator

Condenser

Refrigerant cycle

Fan for cir-culation

Fan for out-going air

Compressor Expelled air intake from the room

Circulation intake from the room

Cable holder

Air intake exhaust

Air filter circulation

Air filter exhaust

Air outlet

Page 6: REMKO RKL 290 / RKL 350 Portable Air Conditioner

6

1 “I / 0” button

The unit is switched on or off with button 1.

2 “MODE” button

Button 2 is used to switch between “Cooling” mode and “Ventilation” mode. Each time the button is pressed, the speed of the fan changes. The LEDs of display 8 indicate the selected speed. In “Cooling” mode, the unit cools the room to a

set value as long as the LED 7 “COMP ON” is lit up. The temperature can be set in a range be-tween 18 and 30°C. The fan speed can be freely selected as follows.

Adjusted fan sped: LED “AUTO” Highest fan speed: LED “HI” Medium fan speed : LED “MED” Lowest fan speed: LED “LO”

The “AUTO” setting is used to automatically ad- just the fan speed to the desired cooling capacity. The greater the difference b e tween the set and current room temperature, the higher the fan speed.

3 “AUTO SWING” button

This button is used to set how the air that is dischar-ged from the unit is distributed.

Press button once =continuous swing function Press button twice =locked swing function Press button third =continuous swing function

4 ▲ / ▼ “THERMO CONTROL” button

This button is used to set the desired target tem-perature in “Cooling” mode. If the Up/Down button 4 is pressed, the adjusted target temperature is shown on the display. The target temperature can be set in 1°C increments between 18 and 30°C.

Upper button = higher target temperature. Lower button = lower target temperature.

Control Panel

5 “TIMER” button

This button is used to automatically activate the unit to switch on and off. When the unit is off, the Timer On function is programmed in one hour increments up to 24 hours via the “SET” button. The LED 10 dis-plays that this function has been activated. When the unit is on, the Timer Off function is programmed in one hour increments up to 24 hours via the “SET” button. The LED 11 displays that this function has been activated.

6 “RESET” button

The programmed timer can be deactivated by press-ing the button 6 “RESET”.

7 “COMP. ON” button

In cooling mode, the unit operates according to the programmed target temperature. If the target tem-perature has been reached, the compressor that cre-ates the cooling capacity switches off. However, the circulation fan continues to operate. The LED 7 lights up while the compressor is in operation.

8 Cooling mode: “AUTO, HI, MED, LO” LED

See also point 2.

9 Ventilation mode: “FAN” LED In ventilation mode, the air in the room is circu-

lated. The unit does not cool. The fan speed can-not be selected and is automatically set to “MED”. The temperature can be changed, how-ever, this does not change the operating mode.

10 “TIMING ON” LED

This LED indicates whether the timer has been acti-vated to switch the unit on.

11 “TIMING OFF” LED

This LED indicates whether the timer has been acti-vated to switch the unit off.

2 1

9 8 7 4 5 13

6 11

10

14

12

3

Page 7: REMKO RKL 290 / RKL 350 Portable Air Conditioner

7

Infrared Remote Control

Inserting the batteries into the remote control

Prior to initial operation, the batteries supplied with the unit (2 type AAA batteries) must be inserted into the re-mote control.

1. Slide off the cover of the battery slot on the back of the remote control.

2. Place the batteries in the slot making sure that the polarity is correct. Use the labelling in the slot.

3. Close the cover.

General Information

The infrared remote control must be protected from moisture.

When the unit is switched on, each change in the settings is automatically transferred to the air condi-tioner. A beep indicates that the data has been prop-erly received.

The transmitter of the infrared remote control must generally transfer changes to settings in the direc-tion of the air conditioner.

It is only possible for data to be properly transmitted if there are no objects located between the transmit-ter and the receiver unit such as doors, drapes, blinds, etc.

Never use new and old batteries at the same time!

We recommend removing the batteries from the re-mote control if the unit is taken out of operation for a longer period of time.

Remove dead batteries and immediately replace them with new batteries that meet quality stan-dards because otherwise they may leak.

Infrared Remote Control Functions All settings can also be made using an infrared remote control. A description of the button functions can be found in the “Control Panel” section. The remote con-trol’s range is approx. 5 meters. Two 1.5 V AAA batteries (included in the scope of the remote control delivery) power the remote control.

1 “ON/OFF” button 2 “MODE” button 3 “TIMER” button 4 “AUTO SWING” button 5 ▲ / ▼ “THERMO CONTROL” buttons

Keep in mind that if there is no plug or it is inser ted incorrectly, water may leak out after the unit has re-sumed operation.

POWER on / off

THERMO CONTROL

MODE

TIMER

AUTO SWING

reset

set

1

5

2

3

4

12 “DRAIN WATER” display

This light indicates that the floating switch of the internal tank has switched off unit operation. The internal tank does not become full during normal operation because the exhaust fan transports the accumulated and evaporated condensation to the outside via the exhaust hose. In conditions with very highs levels of humidity, the moisture cannot be completely expelled and the unit switches off. To resume unit operation after it has automatically been switched off due to a malfunction, proceed as follows:

1. Switch the unit off by pressing the “On/Off” but-ton and unplug it from the power supply.

2. Place a suitable container under the condensa-tion drain of the internal tank. The condensation drain is located at the bottom middle at the back of the unit.

3. Pull the plug from the condensation drain and collect the water that drains out.

4. Then replace the plug.

13 Display

The programmed room temperature is shown on the display.

The current temperature value is increased or de-creased by pressing the Up/Down buttons 3 and 4.

If the timer button 5 is pressed, the display switches to show the remaining hours until the unit is switched on or off.

If after 5 seconds, no buttons are pushed, the tar-get temperate appears on the display again.

14 Infrared remote control receiver

If the unit is operated using the infrared remote control, the impulses are received via the receiver.

Page 8: REMKO RKL 290 / RKL 350 Portable Air Conditioner

8

Prior to Initial Operation The unit is set up in the desired location with the air out-let side facing the room. Follow the safety instructions when setting up the unit.

Keep doors and windows closed during operation.

In case of direct sunlight, make sure to close all curtains and blinds.

Recommendations for optimum unit operation.

5 MIN.

There must be a minimum of 20 cm between the back of the unit and the wall.

Expelling the warm air

During cooling mode, the unit generates warm air. This air must be expelled from the room to retain the cooling effect.

It is therefore necessary to insert the supplied exhaust hose into the air outlet opening at the back of the unit.

The exhaust hose must always be placed at an in-cline in the direction the air is flowing!

In some circumstances, low pressure can occur in the setup room when air is being expelled via a perma-nently attached exhaust hose, e.g. as a result of closed windows or doors. If the performance of the unit is ad-versely affected as a result, make sure that the pressure is corrected.

Make sure that the deflector piece from the top slides down into the notches on the side until it clicks into place.

To ensure that the unit operates ef-fectively, do not place the flexible ex-haust hose supplied at sharp angles and make sure there are no kinks.

Different ways of expelling air

You can expel air from the building as follows:

1. With a flat nozzle.

The flat nozzle supplied can be used in different ways. It is possible to guide the flat nozzle through the open window and se-cure it firmly using straps and suc-tion devices.

The flat nozzle can also be hung through the partially opened win-dow.

2. With a fixed connection to the ex-haust hose (wall lead-through).

The hose supplied is firmly con-nected to a wall lead-through. Lead-through kits can be pur-chased as accessories.

Circulation filter

Condensation drain with plug

You may not extend the exhaust hose.

The air expelled from the unit contains a certain amount of moisture. We therefore recommend ex-pelling the air to the surroundings or the outside.

After unpacking the unit, place it on its transport wheels and let it stand for a minimum of 5 min. before switching it on.

Place the unit securely on a level and firm surface. An uneven surface can cause vibra-tions and disruptive noises.

Before plugging in the power cord, make sure that the required current is available! 230V / 1~, N, PE / 50 Hz.

If extension cords are necessary, make absolutely sure that they are sufficiently thick.

All extensions of the power cords must be sufficiently thick and may only be used if they are completely extended.

Make sure that there is a plug for the condensation drain and that it has been securely placed. Water may leak out after the unit be-comes operational.

Never operate the unit without the intake filter. Without an air intake filter, the plate fins of the evaporators become dirty and the unit’s performance is ad-versely affected.

Make sure that people and objects, such as plants in the room, are not directly in the path of the expelled air.

Exhaust filter

Page 9: REMKO RKL 290 / RKL 350 Portable Air Conditioner

9

Timer Operation

The timer can be preset to switch the unit on or off for a maximum of 12 hours. Pressing the “SET” button in-creases the time until the unit is switched on or off by one hour. The number of hours is shown on the display. Timer switches unit off automatically: 1. W hen the un i t i s on , p res s t he

“SET” button; the “OFF” LED lights up. 2. Set the desired amount of time until the unit is

switched off with “SET” button. Keep in mind that after the setting has been made, the display changes to show the target temperature.

3. After the set amount of time has elapsed, the unit switches off automatically.

Timer switches unit on automatically:

The unit switches on with the most recently made set-tings. If you want different settings, you must switch the unit on, make the changes and then switch the unit off again. 1. When the unit is switched off, press the “SET” but-

ton ; the “ON” LED lights up. 2. Set the desired amount of time until the unit is

switched on with the “SET” button. Keep in mind that after the setting is made, the dis-play changes to show the target temperature.

3. After the set amount of time has elapsed, the unit switches on automatically.

Initial Operation Prior to initial operation, the air intake and outlet open-ings must be inspected for foreign bodies and the air in-take filter for dirt. Blocked or dirty grilles and filters must be cleaned immediately. See the chapter “Maintenance and Service“.

Cooling mode 1. Switch the unit on with the “I/O” button. 2. Select cooling mode with the “Mode” button.

The “AUTO” LED must be lit up. 3. Set the target temperature you want with the

“THERMO CONTROL” buttons. The selected target temperature appears on the display.

4. If the set fan speed is too high or too low, the de-sired fan speed can be set by pressing the “MODE” button.

Fan mode (circulation)

1. Switch the unit on with the “I/O” button

2. Select fan mode with the “MODE” button. The “FAN” LED must be lit up.

Information about timer mode (timer clock)

The timer function is reset by pressing the “I/O” but-ton.

If the “SET” button is pressed while the timer is acti-vated, the remaining time is shown on the display and can be changed using the same “SET” button.

If the timer is programmed, this setting may be lost if the unit is disconnected from the power supply.

Shutting Down the Unit To shut down the unit, always switch it off with the “Power” button on the control panel or via the remote control. Only now can you unplug it from the power sup-ply. Never shut the running unit off by pulling the power plug.

Storage

If the unit is to be taken out of operation for a longer pe-riod of time, for example, over the winter, proceed as follows:

1. Let the device run for approximately 2 hours in circu-lation mode (FAN) to dry the surface of the evapora-tor plate fins. This removes the remaining moisture from the unit and prevents unpleasant odours when the device is put back into operation.

2. Switch off the unit by pressing the “I/O” button, un-plug the unit from the power supply and roll up the power cord.

3. Make sure that the cable is not bent and there are no kinks. The cable can be attached to the back of the unit.

4. Place a suitable container under the condensation drain of the internal tank. The condensation drain is located at the bottom at the back of the unit.

5. Pull the plug from the condensation drain and collect the water that drains out.

6. Then replace the plug. Keep in mind that if there is no plug or it is inserted incorrectly, water may leak out after the unit has re-sumed operation.

7. Store the unit in an upright position in a dry location that is protected from direct sunlight and dust.

8. To prevent dust from getting inside the unit, protect it with, for example, a plastic cover.

Page 10: REMKO RKL 290 / RKL 350 Portable Air Conditioner

10

Cleaning the plastic housing:

For cleaning, use only a clean, soft and slightly moist towel to carefully wipe the housing.

Please observe the following: Never use chemical cleaners or polish to clean the

unit. They can damage the surface.

Only use lukewarm water. Maximum 40°C .

Make sure that no moisture gets into the unit. This can damage the internal components.

Never clean the unit under a stream of water.

Thoroughly clean the air intake and outlet openings on a regular basis. This is where the most dirt accumulates in the short-est period of time.

Maintenance and Service Regular maintenance and observance of some basic principles are required to ensure a long service life and to keep the unit functioning properly. However, the unit should be inspected at least once a year and thoroughly cleaned after long periods of use. The entire cooling system is a low-maintenance, closed-loop system and may only be serviced by authorised service centres.

Before performing any work on the unit, make sure to switch the unit off and unplug the power cord.

Never operate the unit without the air filter. The air filter prevents the condenser from becoming dirty and the performance of the unit from being ad-versely affected.

Cleaning the Filter The unit is equipped with two air intake filters. These can be removed from the back of the unit. The filters must be cleaned at regular intervals. Clean the air filters after no more than 100 hours of operation. If the air is heavily contaminated, reduce this time period accord-ingly.

1. Switch the unit off with the On/Off button on the control panel or the infrared remote control.

2. Unplug the unit.

3. Remove the filter from the unit.

4. Clean the dust that has accumu-lated from the filter. You can use a vacuum cleaner.

5. If the dust filter is very dirty, wash it with a lukewarm soap solution.

6. Let the filter air dry.

7. Replace the filter in the unit.

8. Make sure that the filter is dry and undamaged.

Filter

Wiring Diagram

Legend PCB1 = Control panel PCB2 = Control board SM = Swing motor M1 = Circulation fan motor M2 = Exhaust fan motor KM = Water pump CM = Compressor motor OLP = Overload protection CX1 = Capacitor motor (M1) CX2 = Capacitor motor (M2) CX3 = Capacitor (compressor motor) TH = Thermostat sensor MS1 = Microswitch (water tank full) Colour code Y = Yellow W = White R = Red BU = Blue BR = Brown BK = Black GR = Grey

Page 11: REMKO RKL 290 / RKL 350 Portable Air Conditioner

11

Troubleshooting This unit has been designed using state-of-the-art manufacturing processes and it has been tested repeatedly to ensure that it is working properly. However, should problems occur, refer to the following list.

Unplug the unit from the power supply before perform ing any work on it!

Problem Possible cause Check Remedy The unit does not start or switches itself off automati-cally.

Power failure. Are all other electrical compo-nents working?

Check current and wait for the device to start again.

Defective power fuse / main switch is off.

Are all currents for lighting functional?

Replace power fuse. Switch on main switch.

Power supply line damaged. Are all other electrical compo-nents working?

Maintenance by authorised personnel.

Temperature range is either too high or too low. Is the fan still working? Keep the unit within operating

temperature range 20 to 35°C.

Water tank is full. Is the “Tank Full” signal light lit up? Empty tank. See page 7.

The surrounding temperature is outside of the operating range (16 to 35 °C).

Does “E1“ appear on the dis-play?

Do not operate the unit out-side of the operating range.

The exhaust hose is bent, ex-tended, facing downwards or blocked.

Does the cooling performance improve when the device is operated without an exhaust hose and without a filter?

Make sure that the exhaust channel is not blocked.

Dirty filter Input and/or output opening blocked by foreign matter.

Are the filters dirty? Does the cooling performance improve when the device is operated without a filter?

Clean filter and reinsert it into the unit.

Minimum clearance is insuffi-cient.

Has the minimum distance of 50 cm been maintained? Maintain minimum distance.

Windows and doors open / thermal load increased.

Has something been changed in the design or application?

Close windows and doors / reduce thermal load.

Low pressure in the setup room when operating the unit.

Does the cooling performance improve when a door or win-dow is opened?

Correct pressure in the setup room.

“Cooling” operating mode not set.

Is the “AUTO, HI, MED or LO“ LED lit up in the display?

Set operation mode to “AUTO, HI, MED or LO“.

Device is switched on with the timer function.

Is the “AUTO, HI, MED, LO or FAN“ LED lit up? Press the I / 0 button again.

Temperature setting too high. Is the temperature setting higher than the temperature of the room?

Lower temperature.

Excess voltage due to light-ning.

Was there lightning recently in the region?

Unplug the unit from power supply with switch 5 and re-start.

The unit does not to respond to the infrared remote con-trol.

Remote-control batteries are dead or the transmission dis-tance is too far.

Does the button function work at a distance of approx. 1 m?

Replace batteries / reduce distance or change lo-cation.

Polarity of the batteries is in-correct after replacement. Is the polarity correct? Insert the batteries correctly.

Pay attention to the labels.

Condensation water leaks out of the device.

The device is not standing up-right. Is the device upright? Place upright and make sure it

is firmly in place.

The plug for the condensation drain is not inserted correctly or is damaged.

Is water dripping out of the condensation drain?

Insert the plug correctly or re-place if necessary.

The unit is either not cooling at all or only cooling a little bit.

Should the unit still not be working despite these checks, please contact an authorised service centre.

Page 12: REMKO RKL 290 / RKL 350 Portable Air Conditioner

12

1) Room temperature WB 35°C/DB 24°C 2) Distance 1m

Customer Service and Guarantee For the guarantee to be valid, the purchaser or his cus-tomer must completely fill out the “guarantee certificate” enclosed with all units and send it back to REMKO GmbH & Co. KG.

The units are repeatedly tested at the production site to ensure that they are working properly. If a malfunction occurs that cannot be eliminated by the operating per-sonnel, please contact your dealer or contact person.

Only authorised personnel may come into contact with the cold cycle. This ensures that refrigerant does not escape into the environment when the unit is being re-paired.

Both the refrigerant and the system parts are subject to special requirements for disposal. The refrigerant in use is a safety refrigerant. This means that, should damage occur, the quantities released will not cause injury to the respiratory systems of people and animals.

Important information about recycling!

Environment and Recycling

Do not touch the liquid refrigerant as it can freez e the skin!

Operation/handling which does not comply with these instructions is prohibited! In cases of non-compliance, we assume no liability and the guarantee becomes null and void.

Proper use

The manufacturer assumes no liability for damage re-sulting from non-compliance with manufacturer specifi-cations and legal requirements, or if modifications are made to the units.

Technical Data

Type designation RKL290 S-Line

Nominal cooling capacity 1) kW 2.98

Energy efficiency class cooling A

Energy efficiency ratio EER 2.66

Dehumidification capacity max. l/h 1.9

Operational area (size of room), approx. m³ 90

Operating range indoor unit °C / % r.F. 18 to 35 / 35 to 85

Refrigerant R 410A

Operating pressure max., refrigeration cycle kPa 1900 / 2800

Refrigerant, basic quantity kg 0.73

Circulating air volume per speed m³/h 370 / 410 / 430

Sound pressure level per speed) dB(A) 49 / 51 / 52

Power supply V/Ph/Hz 230 / 1~ / 50

Protection type IP IP 20

Nominal power consumption1) kW 1.12

Nominal current consumption1) A 5.04

Operating medium Fresh air, max. 80% relative hu-

midity

Exhaust air hose, length / diameter mm/mm 1250 / 125

Dimensions height mm 825

width mm 450

depth mm 380

Weight kg 35.0

Serial number 630... 568...

Ref. No. 1615290 1615291

LRA A 21

Nominal current consumption / Standby A 0,03

RKL350 S-Line

3.57

A

2.64

2.0

100

18 to 35 / 35 to 85

R 410A

1900 / 2800

0.75

380 / 430 / 450

49 / 51 / 52

230 / 1~ / 50

IP 20

1.35

5.97

Fresh air, max. 80% relative hu-midity

1250 / 125

825

450

380

35.0

631... 569...

1615350 1615351

25

0,03

Page 13: REMKO RKL 290 / RKL 350 Portable Air Conditioner

13

No. Description

RKL 290 S-Line RKL 350 S-Line

19 Microswitch 2 (tank) 1107019 1107019 1107019 1107019

20 Evaporator 1107057 1107057 1107058 1107058

21 Compressor cpl. 1107059 1107059 1107060 1107060

22 Control panel foil 1107023 1107023 1107023 1107023

23 Control panel circuit board 1107024 1107024 1107024 1107024

24 Control board 1107025 1107025 1107025 1107025

25 Fan motor (circulation) 1107026 1107027 1107026 1107027

26 Evaporator housing 1107028 1107028 1107028 1107028

27 Fan housing (circulation) 1107029 1107029 1107029 1107029

28 Fan wheel (circulation) 1107030 1107030 1107030 1107030

29 Fin motor 1107031 1107031 1107031 1107031

30 Filter (exhaust) 1107032 1107047 1107032 1107047

31 Power supply with plug 1107033 1107033 1107033 1107033

32 Capacitor compressor 1107061 1107061 1107062 1107062

33 Capacitor fan motor (circulation)

1107037 1107037 1107038 1107038

34 Capacitor fan motor (exhaust)

1107039 1107039 1107040 1107040

Infrared remote control 1613135 1613135 1613135 1613135

Exhaust air hose cpl. 1107042 1107048 1107042 1107048

Ref. No.

Exploded View

When orderig parts please indicate ref. no and machine no. (see type plate).

No. Description

RKL290 S-Line RKL350 S-Line

1 Cover, front 1107000 1107043 1107000 1107043

2 Recessed grip 1107001 1107044 1107001 1107044

3 Control panel cover 1107002 1107002 1107002 1107002

4 Air outlet grille 1107003 1107003 1107003 1107003

5 Plate fins 1107004 1107004 1107004 1107004

6 Adjustable lever

(plate fins) 1107005 1107005 1107005 1107005

7 Cover, rear 1107006 1107045 1107006 1107045

8 Air filter (circulation) 1107007 1107046 1107007 1107046

9 Unit bottom 1107008 1107008 1107008 1107008

10 Transport wheel 1107009 1107009 1107009 1107009

11 Fan housing (circulation) 1107010 1107010 1107010 1107010

12 Fan wheel (exhaust) 1107011 1107011 1107011 1107011

13 Fan motor (exhaust) 1107012 1107012 1107013 1107013

14 Collection tray 1107014 1107014 1107014 1107014

15 Condenser 1107055 1107055 1107056 1107056

16 Water pump cpl. 1107016 1107016 1107016 1107016

17 Floater (reservoir) 1107017 1107017 1107017 1107017

18 Microswitch 1 (tank) 1107018 1107018 1107018 1107018

Ref. No.

Spare Part List

9 10

16

4

6

27

21

1

7 20

26 8

29

17

19 18

15

11

14 12 13

28

3

5

22 23

24

30

31

25

2

33

34

We reserve the right to make changes to dimensions and design in the interest of technical progress.

Accessoires variable wall lead-through 1613118 1613118 1613118 1613118

Page 14: REMKO RKL 290 / RKL 350 Portable Air Conditioner

14

Installation Diagram of the Wall-Lead Through

Installation instructions

1. Create a core hole in the outer wall (maximum wall thickness 480 mm) with a diameter of at least 135 mm. Keep an eye out for possible supply lines in this area!

2. Insert the telescope pipe in the wall lead-through that you created so that the outer pipe (100 mm di-ameter) is on the inner side of the wall. To prevent cold bridges, insulate the telescope pipe with a suitable insulation material.

3. Place bricks around the telescope pipe in the core hole so that it is aligned with both sides of the wall.

4. Attach the safety guard to the outer side of the wall with 4 screws. Mount the safety guard paying attention to the posi-tion of the rain drainage.

5. Insert the back pressure flap inside and attach it with 4 screws as well. The “oben” label on the back pressure flap must be visible from inside!

6. Close the opening on the back pressure flap with the sealing cap when taking the device out of operation, e.g. before winter, to prevent air circulation.

Safety guard Back pressure flap

Sealing cap

Telescope pipe

min. 400 mm

Page 15: REMKO RKL 290 / RKL 350 Portable Air Conditioner
Page 16: REMKO RKL 290 / RKL 350 Portable Air Conditioner

REMKO GmbH & Co. KG Air-conditioning and heating technology D-32791 Lage • Im Seelenkamp 12 D-32777 Lage • P.O. Box 1827 Phone +49 5232 606-0 Fax +49 5232 606-260 E-mail [email protected] Internet www.remko.de