Upload
lytuyen
View
219
Download
0
Embed Size (px)
Citation preview
Real world PN by METAS-conform
PEPA portable instrument
Luis Cachón
VERT-Forum 2015, Dübendorf 20.03.2015
220Testo AG, VERT-Forum 2015, Dübendorf
Introduction
320Testo AG, VERT-Forum 2015, Dübendorf
• Founded in 1957
• Worldwide leading manufacturer of portable and
stationary measurement instruments
Testo in brief
420Testo AG, VERT-Forum 2015, Dübendorf
2012 2013 2014 2015 2016 2017
Last 5 years of solid particle counting
2012 WHO identified soot diesel as most dangerous pollutant
2013 Switzerland periodic control on field for construction machinery, EU
requests feasibility study of PEMS-PN for RDE
2014 Matter delivers golden instrument for PEMS-PN within RDE Euro 6c
EU proposal for PN for NRMM; Testo invited to GEME SWG-3 «in-
service conformity»
2015 VAMV Certification for PEPA
2017 RDE Real Driving Emissions within EURO 6c
Motivation
520Testo AG, VERT-Forum 2015, Dübendorf
2013 New Swiss legislation on PN for
construction machinery
620Testo AG, VERT-Forum 2015, Dübendorf
PEPA – Portable Emission Particle Analyzer
720Testo AG, VERT-Forum 2015, Dübendorf
Measuring and technical requirements
Measuring instrument ordinance SR 941.210 appendix 1
Ordinance on exhaust emission measurement instruments
SR 941.242 appendix 4
Real time detector for PN determination
Removal of volatiles
Ability to be portable: No safety issue, low mass and power
consumption
The candidate PEMS-PN instruments should come along with
their calibration data.
820Testo AG, VERT-Forum 2015, Dübendorf
Post-Dilution ThermoConditioning
raw exhaust gassampling at
tailpipe outlet
Nucleation Evaporation
N E
ho
t d
ilutio
n
heating
AB
CDF
cooling down
dilu
tio
n
920Testo AG, VERT-Forum 2015, Dübendorf
ViPR Thermo-Dilution
1020Testo AG, VERT-Forum 2015, Dübendorf
Particle counting: Diffusion Size Classifier
1120Testo AG, VERT-Forum 2015, Dübendorf
Particle counting: 2 Generation DiSC
1220Testo AG, VERT-Forum 2015, Dübendorf
Particle number concentration [#/cm3]
Modal particle diameter [nm]
Calculated particle mass [mg/m3]
Lung-deposited surface area [μm2/cm3]
PMP compliant Volatile Particle Removal
Features
1320Testo AG, VERT-Forum 2015, Dübendorf
Specifications
Raw gas particle concentration
Particle size
Power consumption
Battery life
1E4 … 1E7 pt/ccm
10 … 300 nm
40 W under normal conditions
4 hours under normal conditions
1420Testo AG, VERT-Forum 2015, Dübendorf
Specifications
Average particle number concentration at the official measurement
< 5x104 cm-3 > 5x106 cm-3Measuring Range: xxx cm-3
5x104 cm-3 5x106 cm-3
Mobility diameter Limits of efficiency
23 nm nanoparticles
41 nm nanoparticles
80 nm nanoparticles
200 nm nanoparticles
30 nm droplets of tetracontane
(number concentration up to 105 cm-3
E < 50 %
50 % < E
70 % < E < 130 %
E < 200 %
E < 5 %
Referent value:
2,5x105 cm-3
1520Testo AG, VERT-Forum 2015, Dübendorf
Efficiency 2nd Generation DiSC-Sensor
0
50
100
150
200
8 16 32 64 128 256 512
Effi
cie
ncy
E /
%
particle diameter / nm
E upper limit
E lower limit
DiSC-Sensor_1@Metas
DiSC-Sensor_2@Metas
DiSC-Sensor_3@Metas
1620Testo AG, VERT-Forum 2015, Dübendorf
Filt
er
Pressurized
air
Classifier
long
DMA
Soot or PAO
generator
excess
Concentration1.47E+3 P/CC
ESC
ESC
CondensationParticle Counter
PN-PEMS CPC 3772
CPC 3025A
excess
ejector
pumpFilter
Diluter
Validation setup
Volatile Particle Remover CPC
CAST Soot generator
PEPA
Diluter
PMP Measurement System
1720Testo AG, VERT-Forum 2015, Dübendorf
y = 1.07xR² = 0.99
1.0E+04
1.0E+05
1.0E+06
1.0E+07
1.0E+04 1.0E+05 1.0E+06 1.0E+07
PE
PA
pa
rtic
le n
um
be
r [#
/ccm
]
PMP particle number [#/ccm]
NM3 vs. PMP, DF10
Linear (NM3 vs. PMP, DF10)
Correlation PEPA vs. PMP (GMD 85nm)
PEPA (DF ≈10) vs PMP (DF ≈1000)
Linear PEPA (DF ≈10) vs PMP (DF ≈1000)
5E4
5E6
PEPA Prototype validation @ 85nm
1820Testo AG, VERT-Forum 2015, Dübendorf
Testo AG develops PEPA: a Portable Emission Particle Analyzer
for field measurements
It is for outdoor application and provides on-line response
Particle counting principle based on Diffusion Size Classifier
compliant with LRV efficiency requirements
Thermo-Dilution to remove nanodroplets from exhaust sample
PEPA is candidate for in-use-compliance testing according to
Swiss new legislation for construction machinery
Summary
1920Testo AG, VERT-Forum 2015, Dübendorf
BAFU (Umwelttechnologieförderung) for the support to develop
portable nanoparticle measurement instrumentation
Simone Krähenbühl (BAFU) and Pierre Comte (AFHB)
(Measurement campaign at AVESCO)
Ralf Stich (Testo AG) for the PEPA project management
Acknowledgements
Thank you for your attention!
Luis Cachón
VERT-Forum 2015, Dübendorf 20.03.2015