NASA Technical Memorandum 106686 Radiant Energy Measurements From a Scaled Jet Engine Axisymmetric Exhaust Nozzle for a Baseline Code Validation Case Joseph E Baumeister Lewis Research Center Cleveland, Ohio (NASA-TM- I06686) RADIANT ENERGY MEASUREMENTS FROM A SCALED JET ENGINE AXISYMMETRIC _XHAUST NOZZLE FOR A bASELINE CUOE VALIDATION CASE (NASA. Lewis Research Center) 19 19 G3/34 N95-11409 Unclas 0019886 August1994 National Aeronautics and Space Administration https://ntrs.nasa.gov/search.jsp?R=19950004996 2020-01-20T03:14:31+00:00Z

Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

NASA Technical Memorandum 106686

Radiant Energy Measurements From a ScaledJet Engine Axisymmetric Exhaust Nozzlefor a Baseline Code Validation Case

Joseph E Baumeister

Lewis Research Center

Cleveland, Ohio

(NASA-TM- I06686) RADIANT ENERGY

MEASUREMENTS FROM A SCALED JET

ENGINE AXISYMMETRIC _XHAUST NOZZLE

FOR A bASELINE CUOE VALIDATION CASE

(NASA. Lewis Research Center) 19 19

G3/34

N95-11409

Unclas

0019886

August1994

National Aeronautics and

Space Administration

https://ntrs.nasa.gov/search.jsp?R=19950004996 2020-01-20T03:14:31+00:00Z

Page 2: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust NozzleFor A Baseline Code Validation Case

Summary

A non-flowing, electrically heated test rig was developed to verify computer codesthat calculate radiant energy propagation from nozzle geometries that represent aircraftpropulsion nozzle systems. Since there are a variety of analysis tools used to evaluatethermal radiation propagation from partially enclosed nozzle surfaces, an experimentalbenchmark test case was developed for code comparison. This paper briefly describes the

nozzle test rig and the developed analytical nozzle geometry used to compare theexperimental and predicted thermal radiation results. A major objective of this effort wasto make available the experimental results and the analytical model in a format to facilitateconversion to existing computer code formats. For code validation purposes, this nozzlegeometry represents one validation case for one set of analysis conditions. Since eachcomputer code has advantages and disadvantages based on scope, requirements, anddesired accuracy, the usefulness of this single nozzle baseline validation case can belimited for some code comparisons.

Introduction

Evaluating thermal radiation propagation from partially enclosed nozzle surfaces canlead to complex analysis methods and expensive experimental testing. Using analyticaltools to follow the propagation of radiant energy within and from a nozzle becomes asubstantial problem as the complexity of the geometry increases. Various analyticalapproaches have been developed and applied to evaluate multi-reflecting nozzle radiation.Each technique has advantages and disadvantages based on its simulation of thefundamentals of radiation physics, analytical modeling requirements, computerrequirements, solution convergence requirements, and accuracy and flexibility to solveboth simple and complex problems. Since there are a variety of analysis tools available, astandard code validation case based on benchmark test data was defined to verify andcalibrate these codes. A non-flowing, electrically heated test rig provided benchmark

radiant energy propagation test data for a baseline axisymmetric convergent-divergentnozzle applicable to aircraft propulsion systems. The electrically heated rig consists ofnozzle hardware, shields, and radiometer. For code validation purposes, this nozzle

geometry represents one validation case for one set of analysis conditions. Since eachcomputer code has advantages and disadvantages based on scope, requirements, and

Page 3: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

desired accuracy, the usefulness of this single nozzle baseline validation case can belimited for some code comparisons.

The primary objective of the electrically heated rig is the validation of computercodes that simulate nozzle surface radiant energy propagation. Computer code validation

required a defined nozzle geometry, measured nozzle surface temperatures, angularmeasurements between nozzle and radiometer, and the spectral wavelength band ofinterest. Extreme care was devoted in providing a direct correspondence between

measured test rig nozzle surface temperatures and the analytical nozzle geometry. Thispaper briefly describes the nozzle test rig and the developed analytical nozzle geometryused to compare the experimental and predicted thermal radiation propagation from of thenozzle. A major objective of this effort was to make available the experimental results andthe modeling information in a format to facilitate conversion to existing computer codeformats. The goal is to establish a baseline computer code validation tool.

Throughout this paper the term "model" will be used in two different applications.The term "model" will be applied when discussing the nozzle hardware geometry that is

used in the test rig. The term "analytical model" is used to represent a data set thatcontains the information required to define the physical attributes of the test rig nozzle foranalysis. The analytical model subdivides the nozzle geometry into a number of finitesurfaces called nodes. The actual number of nodes and their geometry depends on the

desired model representation, accuracy of results, structural design considerations,computer capabilities, and computer computational time requirements. Each nozzle noderepresents a uniform surface temperature over the entire node surface.

Axisymmetric Nozzle Test Rig Apparatus

A non-flowing, electrically heated rig was designed, calibrated, tested, and appliedto verify calculated exhaust system radiant energy propagation from a fixed axisymmetricconvergent-divergent nozzle. The main components in the electrically heated rig are thenozzle model hardware, shields to mask unwanted radiant energy, and a radiometer. The

nozzle model hardware represents the propulsion system geometry from the rotor exitplane through the nozzle divergent flaps. The nozzle model is heated and controlled usingresistance wire, which limits the maximum allowable temperature. A low-temperature limit

is set by the test rig operating conditions and the sensitivity of the radiometer. Theaxisymmetric convergent-divergent nozzle model used in the test rig is shown in Figure 1.Figure 2 shows the orientation of the 24 turbine exit guide vanes included in the model.The turbine rotor exit plane was represented by an electrically heated flat plate attachedupstream of the vanes. A view of the nozzle in the electrically heated test rig is given inFigure 3. This nozzle model is an arbitrary design that does not represent any particularengine configuration. Exhaust nozzle throat and surface areas, expansion ratios, andpower conditions must be defined to calculate actual radiant energy propagation, but arenot critical features for code validation purposes.

2

Page 4: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

The nozzle model is constructed from .060" thick AISA 347 stainless steel with

flanges of either spun or welded sheet metal. The model internal surfaces were gritblasted prior to final assembly. This grit blast operation provides the surface with diffusereflecting characteristics. The nozzle model is mounted on a positioning system thatprovides dual axis azimuth and elevation orientation with respect to the radiometer.Extreme care was devoted to provide the required thermocouple instrumentation for

determining nozzle model wall temperatures for use in the analytical model analysis.Thermocouples were required to record both axial and circumferential nozzle modeltemperature gradients. Axial temperature gradients were present through conductionbetween the model section flanges, while free convection inside the non-flowing modelresulted in top-to-bottom temperature gradients from rising hot air.

Two radiant energy shields exist between the nozzle model and the radiometer.The first shield was installed at the nozzle exit plane to remove nozzle external surfaces,instrumentation, and varioustest rig apparatus from view of the radiometer. This shield

provides an inside view of the nozzle, and is shown in Figure 3. A second, or foreground,shield was placed between the test rig and the radiometer. This shield was used toprevent background radiation from entering the radiometer. Both shields were cooled to35 degrees Fahrenheit and painted with high emissivity paint. This high emissivity paintwas added to absorb room radiation and prevent it from reflecting into the radiometer.

The repositioning of the test rig nozzle model for different elevations and azimuths canrequire adjustments in the foreground shield and radiometer position. The placement anddimensions of the foreground shield were determined from the desired optical field of viewof the radiometer. To maintain a radiometer response greater than 95%, an instrument

incremental scan angle of five degrees was selected, based on a calibration with a small1000 degree Centigrade blackbody source positioned at various angles from the radiometercenterline. This provided the shield center aperture dimensions.

A Barnes Spectralmaster Infrared Research Radiometer Model 12-550 Mark II was

used to acquire the radiant energy. This spectral radiometer was positioned 36 feet awayfrom the axisymmetric nozzle. The radiometer optical head contains the following major

components:

A radiation telescope (Fore-Optics) for collecting radiationA 1000 Hz chopper for optically modulating the radiationA reference cavity (- 56 degree's Centigrade) for comparison of target radiation witha standard reference radiation

A cycling 340 position continuously variable spectral filter system for targetwavelength determination from 1.306 to 14.536 micronsA detector to convert the received radiation to electrical signal. An indiumantimonide (InSb) sensor for wavelengths to approximately 5.5 microns, and

mercury cadmium telluride (HgCdTe) sensor for wavelength above this level.

The precise wavelength band used in the test rig for code validation purposes was 2.9904to 5.0201 microns.

Page 5: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

Axisymmetric NozzleAnalytical ModelingInformation

There area variety of analysistechniques usedto simulate the propagationofradiant energy. Eachanalysis technique hasadvantagesand disadvantagesbasedon itssimulation of the fundamentalsof radiation physics,analytical modelingrequirements,computer requirements,solution convergencerequirements,and accuracy and flexibility tosolve both simpleand complex problems. Since each computer code may have differentoperating efficienciesand computational tradeoffs, this nozzleanalytical casewas notoptimized for any particular code, analysisconditions, or computational time mm=mlzmgtechniques. So for code validation purposes,this nozzleanalytical model representsonlyonevalidation case for one set of analysisconditions. Since each computer code hasadvantagesand disadvantagesbasedon scope, requirements,and desiredaccuracy, theusefulnessof this single nozzlebaselinevalidation casecan be limited for somecodecomparisons.

To simulatethe radiation propagating inside and outside the nozzle, typical analysistechniques calculate view factors and radiation interchange factors between the nozzlesurfaces and the outside environment for different azimuth and elevation positions. These

results relate the percent of emitted surface energy that is incident and absorbed for eachsurface through direct and reflected radiant energy propagation. The percentages ofabsorbed energies can then be applied to energy balance equations. The influence ofmulti-reflecting radiation can lead to non-uniform incident and reflected radiant energyfluxes. Since some analysis techniques require uniform incident and reflected radiant

energy fluxes on each surface node, smaller nozzle sectioning may be a requirement. Seereference 1 for further information regarding limitations, advantages and disadvantages of

analysis techniques. For this validation case, the objective of the nozzle analytical modelsurface sectioning was to achieve the greatest possible accuracy in representing the testrig nozzle model. To accomplish this, the nozzle analytical model was sectioned to directlycorrespond with areas of uniform surface temperature in the test rig nozzle model. The

sectioning of the nozzle model surface geometry for use in the analytical model is shown

in Figure 4 through Figure 7.

The complete interior surface geometry of the analytical model is defined by 288surface nodes. The transition duct and exhaust nozzle are sectioned as shown in Figure 4.

Figure 5 shows how the turbine rotor exit plane was modeled along with the vane supportstructure. The vane orientation sequence and surface numbering sequence are shown in

Figure 6 and Figure 7. Two additional surface nodes (289 and 290) are supplied if theuser needs a nozzle external surface cover, as shown in Figure 8. The complete nozzle

analytical model is composed of four surface types: cylinder, disk, slant cone and polygon.These surface types are shown in Figures 9 and 10. In this case, a circular cone geometryis applied by defining the slant cone surface with a vertex displacement of 0.0 (see Figure10). Each of the 288 nodes in the complete analytical model represents surface areas of

uniform temperature. The actual locations used to measure the nozzle emitted radiantenergy are listed in table 1. This table represents the locations where the nozzle analyticalpredictions are to be compared to test rig radiometer data. The 0.0 degree azimuth andelevation location represent the axial direction, or angle normal to the nozzle exit plane.

Page 6: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

AZIMUTH

(degrees)

0.0

2.5

ELEVATION

(degrees)

0.0

0.0

5.0 0.0

10.0 0.0

15.0 0.0

20.0 0.0

0.030.0

40.0 0.0

50.0 0.0

60.0 0.0

70.0 0.0

80.0 0.0

TABLE 1, RADIOMETER POSITIONING WITH RESPECT TO THE NOZZLE TEST RIG

In analyzing the nozzle geometry, diffusely emitting and reflecting surface

thermophysical property characteristics for the nozzle surfaces can be assumed, and a 0.6

hemispherical emissivity value is a reasonable approximation in the 3 to 5 micron

wavelength band of the IR spectrum. Surface thermophysical properties as a function of

angle were also measured. Although this latter information would more accurately

represent the radiation propagation, the geometry and surface temperatures for this model

produce conditions where the uniform hemispherical emissivity produces calculated results

that compare favorably to the test rig results for the total nozzle. For additional

information regarding the analytical model, surface temperatures or modeling information,

contact the author.

Axisymmetric Nozzle Hot Parts Radiation Experimental Data

After the calibration, data reduction phase, and increased experience gained with

the radiometer, a high level of confidence was established with this test rig. The

radiometer test data established the total nozzle emitted radiant energy propagation

pattern for comparison to analytical code predictions. The following table gives the

Page 7: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

experimentalmeasured total nozzle emitted radiant energy, in watts/steradian after

integrating over the 3 to 5 micron wavelength band. These results correspond to a test rig

temperature condition of 800 degree Fahrenheit for the entire axisymmetric convergent-

divergent nozzle. This data includes atmospheric attenuation. Atmospheric radiation

transmissivity data can be applied to simulate the atmosphere absorption effects.

AZIMUTH

(degrees)

0.0

ELEVATION

(degrees)

0.0

ENERGY

(Watts/steradian)

65.4

2.5 0.0 63.9

5.0 0.0 61.8

10.0 0.0 59.2

15.0 0.0 57.9

20.0 0.0 56.3

30.0 0.0 49.2

40.0 0.0 40.1

50.0 0.0 30.1

60.0 0.0 20.0

70.0 0.0 12.0

80.0 0.0 3.0

TABLE 2, TEST RIG NOZZLE MODEL RADIOMETER RESULTS

The results in table 2 are for comparing analytical predictions using the analytical

modeling information. This experimental test data will be used as a standard baseline code

validation case for comparing different analysis techniques. With this Standard baseline

code validation case, differences between analysis codes will become apparent.

Concluding Remarks

To verify computer codes used to calculate aircraft propulsion nozzle radiant

energy propagation, a non-flowing electrically heated test rig was developed. This paper

briefly describes the nozzle test rig and the developed analytical nozzle geometry used to

compare the experimental and predicted thermal radiation results. The data from the test

rig radiometer established the total nozzle emitted radiant energy propagation pattern for

comparison to analytical code predictions. The experiment measured total nozzle emitted

Page 8: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

radiant intensity in the 3 to 5 micron wavelength band for a nozzle geometry with a givenset of nozzle temperatures and surface thermophysical properties• For code validationpurposes, these nozzle test conditions represent a single validation case. Since eachcomputer code has advantages and disadvantages based on scope, requirements, anddesired accuracy, this validation case may represent conditions that limit code comparisoneffectiveness. The results may also be used for code calibration information or as a codedevelopment tool. A major objective of this effort was to make available the experimentalresults and the analytical model in a format that would facilitate conversion to existing

computer codes.

References

Baumeister, J.F.: "Application of Ray Tracing in Radiation Heat Transfer", NASATM-106206, 1993.

Page 9: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

Figure 1. - Axisymmetric Nozzle test rig model.

Page 10: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

Figure 2. - View of nozzletest rig model vane orientation.

Page 11: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

Figure 3. - Intstrumented nozzle test rig model with water cooled shield.

10

Page 12: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

62 284 47 39 283 24 16 282 1 253,?81

287i ,_. 100

63 55 48 40 32 25 17 9 2

139 13111241 _ 74 24 266108 101 89

..267

140 132 117 109 102 97 86 82 75 64 56 49 41 33 26 18 10 3

110 103 1

141 1331 '='1 I _"_,'_ I 76 2, 268

Top I __S8 _"__111104 65 57 50 42 34 27 19 11 4

1:'_. Jr _.v" 83 _ 4 269

AFT FWD 142 - LEFT SIDE VIEW 77 72 66 58 51 43 35 28 20 12 5

Bottom / 1"_ _288 123 8_ 115 _ 286._,;,_IP_,,J_ f

69 61 54 46 38 31 23 15 8

143 135 128 2_ 270 i67 59 52 44 36 29 21 13 6

119134 127 '._ 4 269

loz C_G.,_V,_ ) _ "

Figure 4.- Nozzle surface numbering sequence.

]]

Page 13: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

257

273

258 276 260

275

259

Figure 5. - Forward turbine and vane supportsurface numbering sequence.

12

Page 14: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

STARTING VANE

VANE /

NUMBERING

INCREASES

IN THIS

DIRECTION

F_ENDING VANE

LEADING EDGE

VANE LEADING EDGES

LIE ON RADIAL LINES

/ TO MODELCENTERLINE .

Figure 6. - Vane orientation sequence.

]3

Page 15: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

Leading Edge

238 I_ AFT FACE

Trailing Edge

TOP VIEW

VIEWING

FWD FACE

VIEWING

AFT FACE

.J(5_z

FROM

MODEL LEFT

SIDE VIEW

FROM

MODEL TAIL-ON

END VIEW

Figure 7. - Vane surface numbering sequence.

14

Page 16: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

290\

\

289_\

Figure 8. - Nozzle extemal surface cover numbering sequence.

15

Page 17: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

f

RADIUS -_

ROLL

Xmax. Angle ..I

YAW

( CYLINDER )

_. NORMAL

PITCH

Y

LENGTH > 0

RADIUS > 0

0 ° < max. Angle <360 °

.,)

YAW

max. Radius -I

rain. Radius

ROLL

X

(

Z

P_CH

max. Angle

0 < min. Radius < max. Radius

0° < max. Angle <3600

DISK )

Figure 9. - Cylinder and disk surfaces primitives.

16

Page 18: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

f

ROLL

ZYAW

DISPLACEMENT

NORMAL

PITCH

s •

/" - / max. Angle_- mm. Angle

Base Radius > 0

0 ° < min. Angle < ma:_ Angle< 360 °

(SLANT CONE)

f Z

J i ,_,_ _._-_,_._&_.s PITCH/ _v'O22°o=S2'E_•

( POLYGON )

Figure 10. - Slant cone polygon surfaces primitives.

17

Page 19: Radiant Energy Measurements From a Scaled Jet Engine ... · Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle For A Baseline Code Validation Case Summary

FormApprovedREPORT DOCUMENTATION PAGE OMBNo. 0704-0188

Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instru.ctions, .s_ching exi_ing data sour.ces.,gathering arid maintaining the data needed, and comlpl_ing .an.d.rev.lewing !he collectior_, of information. :_pno comments r.egar.m.ng tr,.s ouroen e.st_mateprany omeres .p.ect..of tinscollection of information, including suggestions ror reoucmg this oumen, to wasnCngton Heaoquarters _erv_ces, ulrectorate for imorma_ton upermmns aria Hepons, 1;']b JanersonDavis Highway, Suite 1204, Arlington, VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188), Washington, DC 20503.

1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED

August 1994 Technical Memorandum

4. TITLE AND SUBTITLE 5. FUNDING NUMBERS

Radiant Energy Measurements From a Scaled Jet Engine Axisymmetric ExhaustNozzle for a Baseline Code Validation Case

6. AUTHOR(S)

Joseph E Baumeister

7. PERFORMINGORGANIZATIONNAME(S)ANDADDRESS(ES)

National Aeronautics and Space AdministrationLewis Research Center

Cleveland, Ohio 44135-3191

9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES)

National Aeronautics and Space Administration

Washington, D.C. 20546-0001

WU-505--62-70

8. PERFORMING ORGANIZATIONREPORT NUMBER

E-9042

10. SPONSORING/MONITORINGAGENCY REPORT NUMBER

NASA TM- 106686

11. SUPPLEMENTARYNOTES

Responsible person, Joseph E Banmeister, organization code 4230, (202) 358--0694.

12a. DISTRIBUTION/AVAILABILITY STATEMENT

Unclassified - Unlimited

Subject Category 34

12b. DISTRIBUTION CODE

13. ABSTRACT (Maximum 200 words)

A non-flowing, electrically heated test rig was developed to verify computer codes that calculate radiant energy propaga-tion from nozzle geometries that represent aircraft propulsion nozzle systems. Since there are a variety of analysis tools

used to evaluate thermal radiation propagation from partially enclosed nozzle surfaces, an experimental benchmark test

case was developed for code comparison. This paper briefly describes the nozzle test rig and the developed analytical

nozzle geometry used to compare the experimental and predicted thermal radiation results. A major objective of thiseffort was to make available the experimental results and the analytical model in a format to facilitate conversion to

existing computer code formats. For code validation purposes, this nozzle geometry represents one validation case for one

set of analysis conditions. Since each computer code has advantages and disadvantages based on scope, requirements, and

desired accuracy, the usefulness of this single nozzle baseline validation case can be limited for some code comparisons.

14. SUBJECT TERMS

Radiator heat transfer; Code validation; Thermal analysis; Jet engine; Exhaust nozzle;

Experimemal data

17. SECURITY CLASSIFICATION 18. SECURITY CLASSIFICATION

OF REPORT OF THIS PAGE

Unclassified Unclassified

NSN 7540-01-280-5500

19. SECURITY CLASSIFICATION

OF ABSTRACT

Unclassified

15. NUMBER OF PAGES

1916. PRICE CODE

A0320. LIMITATION OF ABSTRACT

Standard Form 298 (Rev. 2-89)

Prescribed by ANSI Std. Z39-18298-102