phase in 1 / 1 phase out ( ) 10kVA 1 6kVA PW100 SERIES Security General Specifications : Pure Wave Power PW100 series are true online double conversion UPS systems, manufactured with the state of the art, PWM and IGBT technology, producing microprocessor controlled pure sinewave output. N+X parallel redundancy Online double conversion with DSP control Input current harmonic: <3% High output power factor 0.9 Optimization battery group, quantity of battery : 16/18/20 pieces (optional) Wide input voltage range: 120~276Vac Wide input frequency range (50Hz : 45~55Hz / 60Hz : 54~66Hz) Support generator input Support economic (ECO) operation mode Self-testing when UPS startup Cold start Options : SNMP card/ Relay card/ Parallel card

PW100 SERIES - Pure Wave Powerpurewavepower.co.uk/.../woocommerce_uploads/2014/10/PW100-SERI… · phase in 1 / 1 phase out 10kVA 1 6kVA PW100 SERIES Security General Speci˜cations:

Embed Size (px)

Citation preview

Page 1: PW100 SERIES - Pure Wave Powerpurewavepower.co.uk/.../woocommerce_uploads/2014/10/PW100-SERI… · phase in 1 / 1 phase out 10kVA 1 6kVA PW100 SERIES Security General Speci˜cations:

pha

se in

1

/1ph

ase

out (

)10

kVA

1

6kVA

PW100 SERIES

Security

General Speci�cations :

Pure Wave Power PW100 series are true online double conversion UPS systems, manufactured with the state of the art, PWM and IGBT technology, producing microprocessor controlled pure sinewave output.

• N+X parallel redundancy • Online double conversion with DSP control • Input current harmonic: <3%• High output power factor 0.9• Optimization battery group, quantity of battery : 16/18/20 pieces (optional)• Wide input voltage range: 120~276Vac• Wide input frequency range (50Hz : 45~55Hz / 60Hz : 54~66Hz)• Support generator input • Support economic (ECO) operation mode• Self-testing when UPS startup• Cold start• Options : SNMP card/ Relay card/ Parallel card

Page 2: PW100 SERIES - Pure Wave Powerpurewavepower.co.uk/.../woocommerce_uploads/2014/10/PW100-SERI… · phase in 1 / 1 phase out 10kVA 1 6kVA PW100 SERIES Security General Speci˜cations:

Technical Speci�cations

2

Line modeBatt. Mode

Line modeBypass mode

64/20

Audible & Visual AlarmsLED & LCD Display

Overload40A(Breaker) 60A(Breaker)

<55dB

±96/108/120VDC (Optional)Capacity (Standard unit) 12V-7Ah/9Ah

1A (Standard unit);Long run unit Max.current 10A (Charge current can be set according to battery capacity installed)

Load≤110%: Last 60mins, ≤125% Last 10mins , ≤150% last 1min, >150% turn to bypass mode immediatleyTransfer Time Mains to battery : 0ms ; Mains to bypass : 0ms

Bypass Voltage Rage

Max.Voltage : 220V: +25%(Optional +10%,15%,20%) 230V: +20%(Optional +10%,15%)

240V: +15%(Optional +10%)

ECO RangeHarmonic distortion (THDi)

Same as the bypass<3%(100% Linear load)

PW106 PW1106k/5.4k 10k/9k

120~276VAC

Min.Voltage : 220V: - 45%(Optional -20%,- 30%)

MODEL

OUTPUTVoltage Range

Hold Whole System Line Mode: Turn to bypass ; Backup Mode :Shut down UPS immediatley

Short CircuitOverheat

Operating Frequency RangePower Factor

Power Factor

TemperatureWORKING ENVIRONMENT

PHYSICS CHARACTERISTIC

Alarm and switch off

Battery VoltageBATTERYEfficiency

Dimension: ( DxWxH ) mm

0-95% (Non-consending)- 25°C ~ 55°C

RS232, USB, SNMP Card ( Optional ), Parallel Card ( Optional ) , Relay Card (Optional)

502x250x616

Net Weight (kg)

Noise level< 1500m

0°C ~ 40°C

Upon power on and software controlAdvanced battery management

Line failure , Battery low , Overload, System fault

Communication interface

LCD Display

>93.5

3:1

Line mode, Batt. Mode, ECO mode , Bypass mode , Battery low , Overload and UPS fault

Low Battery VoltageSelf-DiagnosticsBattery

62/18

Operating Voltage Range220/230/240VAC

INPUTCapacity(VA/Watts)

Norminal voltage

Elevation

Storage TemperatureRelative Humidity

Crest Factor

Charging current

Typical Recharge Time

STSTEM FEATURES

Input voltage , Input frequency , Output volatge , Output frequency , Load percentage , Battery voltage , Inner temperature & Remaining battery backup time

0.9

≤5% with non-linear load

220/230/240VAC

6-8 hours (To 90% full capacity)

Generator Input Support

Voltage Range ±1

50Hz:(45~55Hz);60Hz:(54Hz~66Hz)≥0.99

Frequency±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional)

50/60(±0.1)Hz

Harmonic Distortion(THDv)≤2% with linear load

Speci�cations are subject to be changed without prior notes*