2
www.optexamerica.com -*2$)" ELITE T Active Infrared Door Sensor for Swing Doors Full Time Presence Detection The OPTEX Pro-Swing ELITE T is designed to detect moving or stationary people in the swing path of the door. With a large and adjustible detection area, the OPTEX Pro-Swing ELITE T stays active even when the door is in motion, providing safety all of the time! No overhead safety sensor is required, and built-in self-monitoring capability ensures a high level of performance over the life of the sensor.

ProSwing EliteT Datasheet EN

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

www.optexamerica.com

ELITE T

Active Infrared Door Sensorfor Swing Doors

Full Time Presence Detection

The OPTEX Pro-Swing ELITE T is designed to detect moving or stationary people in the swing path of the door. With a large and adjustible detection area, the OPTEX Pro-Swing ELITE T stays active even when the door is in motion, providing safety all of the time! No overhead safety sensor is required, and built-in self-monitoring capability ensures a high level of performance over the life of the sensor.

800-877-6656 310-898-1098 www.optexamerica.com

18730 S Wilmington Ave, STE 100, Rancho Dominguez, CA 902205100 Reagan Drive, STE 16, Charlotte, NC 28216 (East Coast O�ice)

ELITE T

Features & Benefits

Specifications

Dimensions

1 7/16”

2 5/

16"

1 1/4”

Ap

pro

x. 8

1/4

"

Ap

pro

x. 1

0 5

/8"

15/16”

1 1

/4"

1”

2 5/16”

2 1

/4"

10 3/4"

1 1

/4" OMS-102OA-603 T

OC-904C T

Operation indicator

1 1

/8"

LOT.

xxx

xyyz

zzz

Activateinput

SafetyoutputActivateoutput

Stalloutput

Sa

fety

ou

tpu

th

old

tim

e(0

.5 t

o 1

0se

c.)

Sta

ll o

utp

ut

ho

ld t

ime

(0.5

to

10

sec.

)M

ax

Min

Ma

xM

inS

afe

tyre

lay

con

tact

N.O

.N

.C.

1

Sta

llre

lay

con

tact

N.O

.N

.C.

2

Act

iva

tio

no

pe

rati

on

Au

toK

no

win

gA

ct

3 4D

ire

ctio

na

l plu

g

Op

era

tio

nin

dic

ato

r

14

32

78

6

OC

-904

C T

Ma

de

in J

ap

an

Motor input

Test

inp

ut

Enab

leD

isab

le

Po

we

r su

pp

ly

Po

we

r c

on

sum

pti

on

: 1

2 t

o 2

4V

AC

±1

0%

:

12

to

30

VD

C:

< 2

.2W

(<4

VA

at

AC

)

at

2 O

A-6

03

T

&

1 O

C-9

04

C T

&

1 O

MS

-10

2

5Test

inp

ut

Hig

hLo

w

78

Ma

nd

ato

ry

5

6Test

ou

tpu

t(A

ctiv

ate

)

Enab

leD

isab

le

3 2/8"

2 9

/16

"

Single swing Doubleegress

Simultaneous pair

6'7"

7"

1'2"

6"

2'9"

5'5"

10"

1'11"

3"

3'

A

B

C

D

E

FGH

I

J

K

L

M

NO

1'4"

4'2"

2'6"

5'6"

3'10"

7'6"

8"

1'4"

7"

3'2"

6'2"

2'1"

6"

3'4"1'8"

4'8"

3'

6'3"

4'7"

H

J

L

N

B C D

E

F

G

I

K

M

O

A

Large and Adjustible Detection AreaThe Pro-Swing Elite T has a large detection area which can detect beyond the normal area around the moving part of the door. The sensor creates a layer of awareness around the door to ensure safety.

No Overhead Safety Sensor Required

Monitoring Capability

The OPTEX Pro-Swing Elite T provides a full detection pattern that covers the entire swing path of the doors in full open and full closed positions. There is no need for an overhead safety sensor.

The Pro-Swing Elite T has built-in monitoring capability: it monitors all of its critical functions and notifies compatible controls when an error occurs. Self-monitoring capability ensures a high level of performance over the life of the sensor.

ModelCover colorMounting ht.Detection areaDetection method

Detection angle

Operation indicator

Current drawResponse timeOperating temp.WeightAccessories

ModelPower supplyCurrent drawActivate outputSafety ouputStall outputRelay hold timeResponse timeOperation indicator

Operating temp.WeightAccessories

OA-603 T Black/Silver6’7” to 8’2”See detection areaActive Infrared Reflection (Presencedetection type) Threshold area ±5 (inside & outside)Adjustments: Swing area ±5 (inside & outside)Green: stand-by; blinking red: thresholdarea detection active; blinking yellow: learning120 mA Max<0.3 sec.–4 to +131°F8.2 oz. 1 sensor cable 7” (0.2m), 9 mounting screws, 1 operation manual, 3 mountingtemplates

OC-904C T12 to 24 VAC / 12 to 30 VDC500mA max.*Form A relay 50V, 0.3 A (resistance load) Form B relay 50V, 0.3 A (resistance load)Form B relay 50V, 0.3 A (resistance load)(Safety & Stall Output only) 0.5 to 10s<0.3 sec.Green: stand-by; Red: door opening; Orange: lockout-4 to +131°F2.2 oz.1 two sided tape; 2 T-tap connectors

* When 2 OA-603 units and 1 OC-904C T is used

ProSwing ELITE T

800-877-6656

18730 S Wilmington Ave,STE 100, Rancho Dominguez, CA 90220

310-898-1098 www.optexamerica.com

5100 Reagan Drive, STE 16, Charlotte, NC 28216 (East Coast Office)