6
© 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 1 / 6 FILE NAME : WWR.LED-B3.SPEC November 27, 2017 axislighting.com RECESSED WALL WASH Notes Type NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY 400 lm/ft 4.9 W/ft 82 lm/W 500 lm/ft 6 W/ft 83 lm/W 750 lm/ft 9.1 W/ft 83 lm/W 1000 lm/ft 12.7 W/ft 79 lm/W Please consult factory for custom lumen output and wattage. PERFORMANCE PER LINEAR FOOT AT 3500K Project The louver option provides lengthwise shielding. WWR SL PRODUCT ID LIGHT ENGINE NOM. LUMENS/FT CRI COLOR TEMP. SHIELDING (OPTIONAL) LENGTH (FT) WWR Wall Wash Recessed SL SurroundLite 400 400 lm/ft 80 80 CRI 27 2700 K L black louver 1 1’ nominal SurroundLite 500 500 lm/ft 90 90 CRI 30 3000 K 2 2’ 750 750 lm/ft 35 3500 K 3 3’ 1000 1000 lm/ft 40 4000 K 4 4’ 5 5’ 6 6’ 8 8’ 12 12’ S# system run Outputs between listed min and max are available. Consult factory for outputs outside of the listed range. FINISH VOLTAGE DRIVER CIRCUITS MOUNTING W white 120 120 V DP dimming (0-10V) 1% 1 1 circuit TB9 t-bar 9/16” C custom 277 277 V D dimming (0-10V) 5% 347V standard (2) 2 2 circuits TB15 t-bar 15/16” 347 347 V (1) LT Lutron (3) +E(#) emergency circuit (5) ST screw slot t-bar UNV universal BI bi-level dimming TG9 tegular 9/16” O other (4) TG15 tegular 15/16” DF drywall flange D drywall flangeless DB slip-through bracket DS drywall spackle flange (1) D dimming (0-10V) 5% standard (2) For 347 V only (3) Specify system (4) Please consult factory; see page 2 (5) Specify quantity BATTERY (OPTIONAL) OTHER (OPTIONAL) CUSTOM (OPTIONAL) B# battery pack (integral) F fuse (6) C custom FW(#) flex whip (6’ std) CP Chicago plenum HD hold-down clip Requires 120V or 277V Minimum 4ft; please consult factory (6) Requires 120V or 277V Please specify Consult factory for combinations of wall wash perfekt and Beam 2 cULus Listed Type I.C. IC 5 L E D B O A R D & D R I V E R L U M IN A IR E W A R R A N T Y YEAR Ordering Guide 2 1 /44”

Project Type Notes - axislighting.com Wash Perfekt.SPEC.pdf · Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of

Embed Size (px)

Citation preview

Page 1: Project Type Notes - axislighting.com Wash Perfekt.SPEC.pdf · Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of

© 2016 Axis Lighting Inc.1 . 8 0 0 . 2 6 3 . 2 9 4 7[T] 514 . 9 4 8 . 6 27 2

Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information.

1 / 6 FILE NAME : WWR.LED-B3.SPECNovember 27, 2017 a x i s l i g h t i n g . c o m

RECESSED WALL WASH

Notes

Type

NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY

400 lm/ft 4.9 W/ft 82 lm/W500 lm/ft 6 W/ft 83 lm/W750 lm/ft 9.1 W/ft 83 lm/W1000 lm/ft 12.7 W/ft 79 lm/WPlease consult factory for custom lumen output and wattage.

PERFORMANCE PER LINEAR FOOT AT 3500K

Project

The louver option provides lengthwise shielding.

WWR SL

PRODUCT ID LIGHT ENGINE NOM. LUMENS/FT CRI COLOR TEMP. SHIELDING (OPTIONAL) LENGTH (FT)WWR Wall Wash Recessed SL SurroundLite 400 400 lm/ft 80 80 CRI 27 2700 K L black louver 1 1’ nominal

SurroundLite 500 500 lm/ft 90 90 CRI 30 3000 K 2 2’750 750 lm/ft 35 3500 K 3 3’

1000 1000 lm/ft 40 4000 K 4 4’5 5’6 6’8 8’

12 12’S# system run

Outputs between listed min and max are available.Consult factory for outputs outside of the listed range.

FINISH VOLTAGE DRIVER CIRCUITS MOUNTINGW white 120 120 V DP dimming (0-10V) 1% 1 1 circuit TB9 t-bar 9/16”C custom 277 277 V D dimming (0-10V) 5% 347V standard (2) 2 2 circuits TB15 t-bar 15/16”

347 347 V (1) LT Lutron (3) +E(#) emergency circuit (5) ST screw slot t-barUNV universal BI bi-level dimming TG9 tegular 9/16”

O other (4) TG15 tegular 15/16”DF drywall flangeD drywall flangeless

DB slip-through bracketDS drywall spackle flange

(1) D dimming (0-10V) 5% standard

(2) For 347 V only(3) Specify system(4) Please consult factory; see page 2

(5) Specify quantity

BATTERY (OPTIONAL) OTHER (OPTIONAL) CUSTOM (OPTIONAL)B# battery pack (integral) F fuse (6) C custom

FW(#) flex whip (6’ std)CP Chicago plenumHD hold-down clip

Requires 120V or 277VMinimum 4ft; please consult factory

(6) Requires 120V or 277V Please specifyConsult factory for combinations of wall wash perfekt and Beam 2

cULus ListedType I.C.

IC 5LED

BOARD & DRIVER

LUMINAIREWARRANTY

YEAR

Ordering Guide

2 1/4”

4”

Page 2: Project Type Notes - axislighting.com Wash Perfekt.SPEC.pdf · Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of

© 2016 Axis Lighting Inc.1 . 8 0 0 . 2 6 3 . 2 9 4 7[T] 514 . 9 4 8 . 6 27 2

Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information.

2 / 6 FILE NAME : WWR.LED-B3.SPECNovember 27, 2017 a x i s l i g h t i n g . c o m

RECESSED WALL WASH

Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of continuous runs.Lengths of 1', 2', 4', 8', 12' as well as custom lengths are available in 1' increments. Runs of Wall Wash Perfekt that are greater than 12' in length are designated as systems (S#). This means that the run is comprised of a combination 4', 8' and/or 12' sections to be assembled on site using our joining system. For more information on systems and joining, please refer to the Wall Wash Perfekt installation sheets available for download at www.axislighting.com.

SYSTEM (S#)

FINISHES

Powder coated and custom finishes are also available.

OPTIONAL SYSTEMS WITH BEAM 2

Wall Wash Perfekt can be combined with Beam 2. Wall Wash Perfekt is the same width as Beam 2 and can be joined for a combination of both systems. Please specify the Beam 2 fixtures in the system seperatly.

APPROVALS

Certified to UL and CUL standards Meets NYC requirementsMeets CCEC requirements (Chicago plenum)Suitable for damp locationsIC Rated (Insulated ceiling)

WEIGHT

Recessed LED 4 ft 10.5 lbs / 4.8 kgRecessed LED 8 ft 21.0 lbs / 9.6 kgRecessed LED 12 ft 31.5 lbs / 14.4 kg

Housing Extruded aluminum (0.060'' nominal) Up to 70% recycled contentT-Bar Bracket Die formed sheet steel (22 gauge)Screw Slot T-Bar Bracket Die formed sheet steel (22 gauge)Slip-Through Bracket Die formed sheet steel (18 gauge)Spackle Flange Die formed perforated sheet steel (20 gauge)Flange Extruded aluminum (0.065'' nominal) Visible flange width: 9/16"Interior Brackets Die formed sheet steel (24 gauge)Reflectors Specular aluminumBlank Extruded aluminum (0.075'' nominal)Lens Acrilyc with Microtek detail

OPTICSCONSTRUCTION

ELECTRICAL

Lutron driver L3D - Hi-Lume A-Series EcoSystem 3-Wire Control (1%)LDE1 - EcoSystem H-Series (1%)LDE5 - EcoSystem 5-Series (5%)LTE - Hi-Lume® A-series 2Wires Forward Phase (1%)

Other drivers DALI - Digital Addressable Lighting InterfaceDMX - Digital MultiplexLV - line voltage - Advance Mark 10Xitanium SR - For wireless sensor

Emergency Integral emergency battery pack or emergency circuit optional.

Input Voltage 120V, 277V, 347V, UNV.

Incorporating these components may have limitations or affect the length of the luminaire. Please contact factory for more details.

WARRANTY

Axis Lighting will warrant defective LEDs, boards, and drivers for 5 years from date of purchase. Warranty is valid if luminaire is installed and used according to specifications.If defective, Axis will send replacement boards or drivers at no cost along with detailed replacement instructions and instructions on how to return defective components to Axis.

Runs can accommodate Beam 2 lens and accent modules (order separately).

Wall Wash Perfekt

Beam 2

Accent

OpticsLight guide Patent pending vertical light guide optical systemTrim Black multigroove linear trimLouver (optional) Black deep lenghtwise shielding louver

Page 3: Project Type Notes - axislighting.com Wash Perfekt.SPEC.pdf · Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of

© 2016 Axis Lighting Inc.1 . 8 0 0 . 2 6 3 . 2 9 4 7[T] 514 . 9 4 8 . 6 27 2

Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information.

3 / 6 FILE NAME : WWR.LED-B3.SPECNovember 27, 2017 a x i s l i g h t i n g . c o m

RECESSED WALL WASH

DRYWALL CEILING MOUNTING OPTIONS

Specification sheets and installation sheets for all mountings for WALL WASH PERFEKT luminaires are available for download at www.axislighting.com

TB CEILING MOUNTING OPTIONS

D FLANGELESS WITH 1/4-20 STUD MOUNTING

DB VISIBLE FLANGES WITH SLIP-THROUGH BRACKET

DF VISIBLE FLANGES WITH 1/4-20 STUD MOUNTING

DS SPACKLE FLANGES

2 1/4”

2 3/8”

4”

1/4” 2 1/4”

3 3/8”

4”

1/4” 2 1/4”

2 13/16” 3 3/8”

4”

1/4”

2 1/4”

3”

4”

1/4”

TB15 15/16" T-BAR

2 1/4”

3 3/16”

4”

1/4”

ST SCREW SLOT T-BAR

2 1/4”

2 7/8”

4”

1/4”

TG15 15/16" TEGULAR

TB9 9/16" T-BAR

2 1/4”

2 7/8”

4 ”

1/4”

TG9 9/16" T-TEGULAR

2 1/4”

3 3/16”

4 ”

1/4” 2 1/4”

2 7/8”

4 ”

1/4”

Page 4: Project Type Notes - axislighting.com Wash Perfekt.SPEC.pdf · Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of

© 2016 Axis Lighting Inc.1 . 8 0 0 . 2 6 3 . 2 9 4 7[T] 514 . 9 4 8 . 6 27 2

Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information.

4 / 6 FILE NAME : WWR.LED-B3.SPECNovember 27, 2017 a x i s l i g h t i n g . c o m

RECESSED WALL WASH

All IES files are available for download at: www.axislighting.com

PHOTOMETRIC DATA

LUMINANCE DATA (cd/m2)

Horizontal Angles

Vertical Angle 0 45 90

45 115 1496 1072355 74 159 843765 46 116 709375 13 51 712885 112 112 6369

LUMINANCE DATA (cd/m2)

Horizontal Angles

Vertical Angle 0 45 90

45 144 1864 1335655 92 198 1050965 58 144 883575 16 63 887985 140 140 7934

0° 15°15°

30°

45°

60°

75°

90°

30°

45°

60°

75°

90°

0°90°

154

461

308

615

0° 15°15°

30°

45°

60°

75°

90°

30°

45°

60°

75°

90°

0°90°

192

575

383

766

Total Lumens: 804 lm (for 2ft)Lumens ft/down: 400 lm/ftInput Watts: 9.8 WEfficacy: 82 lm/WIES FILE: WWR-SL-400-80-35-W-2.IES TESTED ACCORDING TO IES LM-79-2008

Total Lumens: 1001 lm (for 2ft)Lumens ft/down: 500 lm/ftInput Watts: 12 WEfficacy: 83 lm/WIES FILE: WWR-SL-500-80-35-W-2.IES TESTED ACCORDING TO IES LM-79-2008

400 lm/ft

500 lm/ft

Horizontal Angles

Vertical Angle 0 22.5 45 67.5 90

0 259 259 259 259 2595 201 206 218 236 26015 107 116 143 187 25325 51 59 83 135 23235 20 26 45 86 19045 1 5 18 50 13155 1 1 2 27 8465 0 1 1 8 5275 0 0 0 1 3285 0 0 0 0 1090 0 0 0 0 0

CANDELA DISTRIBUTION

Horizontal Angles

Vertical Angle 0 22.5 45 67.5 90

0 322 322 322 322 3225 250 257 272 294 32415 134 145 178 233 31525 64 73 104 168 28935 25 32 56 107 23645 2 6 23 63 16355 1 1 2 33 10465 0 1 1 10 6575 0 0 0 1 4085 0 0 0 0 1290 0 0 0 0 0

CANDELA DISTRIBUTION

ZONAL LUMENS

Lumens

Zone

00-10 2610-20 8520-30 13630-40 16040-50 14150-60 10860-70 7570-80 4780-90 25

90

ZONAL LUMENS

Lumens

Zone

00-10 3310-20 10620-30 17030-40 19940-50 17550-60 13560-70 9470-80 5980-90 31

90

PHOTOMETRIC CURVE

PHOTOMETRIC CURVE

Page 5: Project Type Notes - axislighting.com Wash Perfekt.SPEC.pdf · Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of

© 2016 Axis Lighting Inc.1 . 8 0 0 . 2 6 3 . 2 9 4 7[T] 514 . 9 4 8 . 6 27 2

Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information.

5 / 6 FILE NAME : WWR.LED-B3.SPECNovember 27, 2017 a x i s l i g h t i n g . c o m

RECESSED WALL WASH

PHOTOMETRIC DATA

LUMINANCE DATA (cd/m2)

Horizontal Angles

Vertical Angle 0 45 90

45 216 2795 2003455 138 298 1576465 87 217 1325275 23 94 1331885 210 210 11900

0° 15°15°

30°

45°

60°

75°

90°

30°

45°

60°

75°

90°

0°90°

287

862

575

1150

Total Lumens: 1502 lm (for 2ft)Lumens ft/down: 750 lm/ftInput Watts: 18.2 WEfficacy: 83 lm/WIES FILE: WWR-SL-750-80-35-W-2.IES TESTED ACCORDING TO IES LM-79-2008

750 lm/ft

Horizontal Angles

Vertical Angle 0 22.5 45 67.5 90

0 483 483 483 483 4835 375 385 407 440 48615 201 217 267 350 47325 96 110 156 252 43335 37 48 84 161 35445 3 10 34 94 24555 1 2 3 50 15665 1 1 2 16 9775 0 0 0 2 6085 0 0 0 0 1890 0 0 0 0 0

CANDELA DISTRIBUTION ZONAL LUMENS

Lumens

Zone

00-10 4910-20 16020-30 25430-40 29840-50 26350-60 20260-70 14070-80 8980-90 46

90

PHOTOMETRIC CURVE

All IES files are available for download at: www.axislighting.com

LUMINANCE DATA (cd/m2)

Horizontal Angles

Vertical Angle 0 45 90

45 288 3727 2671255 184 397 2101865 116 289 1767075 31 126 1775885 279 279 15867

0° 15°15°

30°

45°

60°

75°

90°

30°

45°

60°

75°

90°

0°90°

383

1150

766

1533

Total Lumens: 2002 lm (for 2ft)Lumens ft/down: 1000 lm/ftInput Watts: 25.4 WEfficacy: 79 lm/WIES FILE: WWR-SL-1000-80-35-W-2.IES TESTED ACCORDING TO IES LM-79-2008

1000 lm/ft

Horizontal Angles

Vertical Angle 0 22.5 45 67.5 90

0 645 645 645 645 6455 500 513 543 587 64915 267 290 356 466 63025 128 146 208 336 57835 50 64 112 214 47245 4 13 46 125 32755 2 2 4 67 20865 1 1 2 21 12975 0 0 1 2 7985 0 0 0 0 2490 0 0 0 0 0

CANDELA DISTRIBUTION ZONAL LUMENS

Lumens

Zone

00-10 6510-20 21320-30 33930-40 39740-50 35050-60 27060-70 18770-80 11880-90 62

90

PHOTOMETRIC CURVE

Page 6: Project Type Notes - axislighting.com Wash Perfekt.SPEC.pdf · Wall Wash Perfekt linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of

© 2016 Axis Lighting Inc.1 . 8 0 0 . 2 6 3 . 2 9 4 7[T] 514 . 9 4 8 . 6 27 2

Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information.

6 / 6 FILE NAME : WWR.LED-B3.SPECNovember 27, 2017 a x i s l i g h t i n g . c o m

RECESSED WALL WASH

With innovative patent-pending asymmetric SurroundLiteTM optics, Wall Wash Perfekt luminaires can be spaced wider apart while maintaining a consistent, quality wall washing effect.

POWERFUL, COST-EFFECTIVE SURROUNDLITETM

10’

10’3’

4’

25 f.c.11 f.c.

25 f.c.

2’

3 Feet From Wall

Verti

cal D

istan

ce F

rom

Ceil

ing

1' 24 23 17 11 7 11 17 23 24 23 17 11 7 11 17 23 242' 26 25 19 13 8 13 19 25 26 25 19 13 8 13 19 25 263' 26 25 20 15 10 15 20 25 26 25 20 15 10 15 20 25 264' 25 25 20 16 11 16 20 25 25 25 20 16 11 16 20 25 255' 21 21 18 15 11 15 18 21 21 21 18 15 11 15 18 21 216' 17 17 15 13 10 13 15 17 17 17 15 13 10 13 15 17 177' 13 13 13 11 9 11 13 13 13 13 13 11 9 11 13 13 138' 11 10 10 9 8 9 10 10 11 10 10 9 8 9 10 10 119' 9 9 8 8 7 8 8 9 9 9 8 8 7 8 8 9 9

10' 10'