Drawing Index Sheet # Sheet Name Issue Date Project Directory Client: Mandana Nabizadeh, DDS & Ali Behzadi, DMD Design Architect: JoeArchitect, Inc. 1422 Delgany Street, Suite LL1 Denver, CO. 80202 720.946.3228 720.946.3004 (fax) Dental Equipment Provider: Patterson Dental Mike Cothern 407.923.5037 [email protected] Building Code Summary Scope of Work: 2,192 sq. ft. interior tenant finish on 1st floor of existing 1 story, fully sprinkled, type V-B building Applicable Codes: 2012 Florida Building Code 2008 National Electrical Code 2010 Mechanical Code 2010 Fuel Gas Code 2010 Florida Energy Code 2010 Plumbing Code 2010 florida Fire Preservation Code 2009 NFPA 101 Life Safety Code w/ Florida Amendments 2009 NFPA 1 Uniform Fire Code w/ Florida Amendments Engineering Standards Manual Orlando Urban Storm Water Management Manual Florida Statutes Florida Administrative Orlando City Code Occupancy Classification: B Construction Type: V-B Tenant Finish Area: 2,192 sq. ft. Gross Building Area: 2,374 sq. ft. Building Height: 1 story Occupant Load Factor: 1 occupant / 100 sq. ft. Occupant Load: 22 Total Exit Width: (0.2"/occupant) * 22 occupants = 4.4" 32" minimum clear width req'd. Number of Exits Required: 1 exit required, ? exits provided Max. Travel Distance to Exit: 200 ft allowed (non sprinkled) 56 ft maximum travel distance Fire Protection: Existing building non sprinklered Architect of Record: WJ WEEKS Archtecture llc AA26002407 1200 East Hillcrest Street Suite 200 Orlando, Florida 32803 407.234.3695 407.888.4930 (fax) Civil Engineer: SK Consortium Inc. EB 7080 1053 North Orlando Avenue Suite 3 Maitland, Florida 32751 407.629.4288 407.629.1656 (fax) Landscape Architect: Daniel A. Rodgers 230 North Glenwood Avenue Orlando, Florida 32751 407.353.0112 Structural Engineer: RDI Structural Engineering, Inc. CA 29982 1135 Pasadena Avenue South Suite 100 South Pasadena, Florida 33707 727.388.1344 MEP Engineers: RBE Consulting Services LLC #27269 2875 Split Oak Court Oviedo, Florida 32766 407.796.3820 407.796.3671fax) Demolition Site Plan C001 C101 Site Development Plan C201 Grading and Drainage Plan C401 Detail Sheet CIVIL LANDSCAPE LA - 100 Existing Tree Plan LA - 200 Landscape Plan & Plant Palette LA - 201 Landscape Planting Details ELECTRICAL Electrical Site Photometric Plan E0.2 Electrical Power & Systems Plans E1.1 Lighting Floor Plan E2.1 E3.1 Electrical Roof Plan E4.1 Power Riser Diagram, Details and Schedules 3-24-14 6-3-15 x-xx-xx x-xx-xx x-xx-xx x-xx-xx x-xx-xx x-xx-xx x-xx-xx x-xx-xx x-xx-xx x-xx-xx 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LA - 300 Irrigation Plan Details & Notes C0 Cover ARCHITECTURE Demolition Floor Plan A 1.0 New Floor Plan A 2 Roof Plan A 2.2 Existing Exterior Elevations A 7.0 New Exterior Elevations A 9.1 A 9.2 New Exterior Elevations 1 Color Renderings Existing Photos A 10.1 A 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Project Directory

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Project Directory

Drawing Index

Sheet # Sheet Name Issue Date

Project Directory

Client:Mandana Nabizadeh, DDS & Ali Behzadi, DMD

Design Architect:JoeArchitect, Inc.

1422 Delgany Street, Suite LL1Denver, CO. 80202720.946.3228720.946.3004 (fax)

Dental Equipment Provider:Patterson DentalMike Cothern

[email protected]

Building Code Summary

Scope of Work: 2,192 sq. ft. interior tenant finish on 1stfloor of existing 1 story, fully sprinkled,type V-B building

Applicable Codes: 2012 Florida Building Code2008 National Electrical Code2010 Mechanical Code2010 Fuel Gas Code2010 Florida Energy Code2010 Plumbing Code2010 florida Fire Preservation Code2009 NFPA 101 Life Safety Code w/ Florida Amendments2009 NFPA 1 Uniform Fire Code w/ Florida AmendmentsEngineering Standards ManualOrlando Urban Storm Water Management ManualFlorida StatutesFlorida AdministrativeOrlando City Code

Occupancy Classification: B

Construction Type: V-B

Tenant Finish Area: 2,192 sq. ft.

Gross Building Area: 2,374 sq. ft.

Building Height: 1 story

Occupant Load Factor: 1 occupant / 100 sq. ft.

Occupant Load: 22

Total Exit Width: (0.2"/occupant) * 22 occupants = 4.4"32" minimum clear width req'd.

Number of Exits Required: 1 exit required, ? exits provided

Max. Travel Distance to Exit: 200 ft allowed (non sprinkled)56 ft maximum travel distance

Fire Protection: Existing building non sprinklered

Architect of Record:WJ WEEKS Archtecture llc AA26002407

1200 East Hillcrest Street Suite 200Orlando, Florida 32803407.234.3695407.888.4930 (fax)

Civil Engineer:SK Consortium Inc. EB 7080

1053 North Orlando Avenue Suite 3Maitland, Florida 32751407.629.4288407.629.1656 (fax)

Landscape Architect:Daniel A. Rodgers

230 North Glenwood AvenueOrlando, Florida 32751407.353.0112

Structural Engineer:RDI Structural Engineering, Inc. CA 29982

1135 Pasadena Avenue South Suite 100South Pasadena, Florida 33707727.388.1344

MEP Engineers:RBE Consulting Services LLC #27269

2875 Split Oak CourtOviedo, Florida 32766407.796.3820407.796.3671fax)

Demolition Site PlanC001

C101 Site Development Plan

C201 Grading and Drainage Plan

C401 Detail Sheet

CIVIL

LANDSCAPE LA - 100 Existing Tree Plan

LA - 200 Landscape Plan & Plant Palette

LA - 201 Landscape Planting Details

ELECTRICAL Electrical Site Photometric PlanE0.2

Electrical Power & Systems PlansE1.1

Lighting Floor PlanE2.1

E3.1 Electrical Roof Plan

E4.1 Power Riser Diagram, Details and Schedules

3-24-14

6-3-15

x-xx-xx

x-xx-xx

x-xx-xx

x-xx-xx

x-xx-xx

x-xx-xx

x-xx-xx

x-xx-xx

x-xx-xx

x-xx-xx

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

LA - 300 Irrigation Plan Details & Notes

C0 CoverARCHITECTURE

Demolition Floor PlanA 1.0

New Floor PlanA 2

Roof PlanA 2.2

Existing Exterior ElevationsA 7.0

New Exterior ElevationsA 9.1

A 9.2 New Exterior Elevations

1Color Renderings

Existing Photos

A 10.1

A 10

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Page 2: Project Directory
Page 3: Project Directory

A 2.3

4

A 2.3

2

A 2.3

6

A 2.3

1

A 2.3

5

Page 4: Project Directory

5

12'-8 3/4"

8'-0 1/2"

8'-2"

X3

Copy/fax

11'-0"

8'-6 1/4"

11'-0"

7'-11 1/4"+/-

11

3

8

4

8'-11"

10'-8"

8'-6"

6'-1" 3'-10 3/4"

2'-8"

3'-6"

2'-0"

Children's Practice

Waiting

104

Adult PracticeWaiting

101

Reception

102

Kids' Area

105

Restroom

106

Open Bay

108

Quiet Room 1

110

Quiet Room 2

111

Sterilization

113Mechanical

115

Med Gas

114

Treatment Hallway

116

Lab

112

Consult

107

Operatory 2

117

Operatory 1

118

Hygiene

119

IT Closet

120

Adult PracticeHallway

121A

Restroom

122Staff Room

123

Doctors' Office

124

Imaging Station

109

10

75'-0"

X1

X2

1

2

X4

4'-0 1/2"

W9

W9

W9

W9

W3

W9

W9

W9

9

9'-2"

3'-2"

Reception Hallway

103

6

11'-10 3/4"6'-4"

8'-0 1/2"

5'-0 1/4"

5'-7"

2'-8"

3'-6"

2'-0"

2'-8"

3'-6"

1'-10 1/2"

3'-5 3/4"

2'-0"

9'-0"

7'-8 1/2"

8'-11 1/4"

10'-0 1/2"

8'-0"

6'-6"

4'-5 1/2" 5'-0" 2'-6"

W3

See FloorPlan Note 9

W8W8W8

4'-2"5'-4"

18'-3 3/4"

11'-10 1/4"

See Floor Plan Note 10

1'-1"

4'-1 3/4" 1'-6"

2'-0"

3'-0"

Adult PracticeHallway

121B

LC

LC

12

13

FEC

FEC

1525

60 min

X > 8205

(a)

pull side

18 min445

1220

48 min

X > 8205

(c)

push side, door provided with

both closer and latch

12 min305

1220

48 min

X > 8205

(b)

push side

Figure 404.2.4.3

Maneuvering Clearances at Recessed Doors and Gates

0'-8"

W9

W9

W9

W9

W9

W9

W9

W9

W9

Partition (P-Types)Schedule# Wall Type Fire Rating Assembly Description

W1 4-7/8" Partition N/A 5/8" Type 'X' GWB applied to each side of 3-5/8" steel studs 24" OC. Height varies; refer to specifications and drawings. See RCP for location of insulation.

W3 4-1/4" Partition N/A 5/8" Type 'X' GWB on finish side of 3-5/8" steel studs 24" OC. Height varies; refer to specifications and drawings. See RCP for location of insulation.

W4 5/8" GWB N/A 5/8" Type 'X' GWB on finish side of existing framing. Height varies; refer to specifications and drawings. See RCP for location of insulation.

W8 6-1/8" Mechanical RoomPartition

N/A 5/8" Type 'X' GWB applied to each side of 3-5/8" steel studs 24" OC and 1-1/4" Kinetics IsoMax resilient channel. Full height assembly from finish floor to BO deck. Provide full 3-1/2" BATT insulation.

W9 1-1/2" Partition N/A 5/8" Type 'X' GWB on finish side of 7/8" steel hat channel 24" OC. Height varies; refer to specifications and drawings. See RCP for location of insulation.

All walls W1 UNO

Page 5: Project Directory
Page 6: Project Directory
Page 7: Project Directory

Mandana Nabizadeh, D.D.S. Children Dentistry

A 9.2

5

A 9.2

5

A 9.2

5

A 9.2

5

NOTE; VERIFY FINAL FRAME SIZE, FABRIC AND ANCHORING TOBUILDING BY CANOPY MANUFACTURER TO MEET CODEREQUIREMENTS. SUBMIT FABRIC AND FRAME COLOR SAMPLESFOR OWNERS REVIEW. REF; SUNDANCE ARCH. PRODUCTS

Page 8: Project Directory
Page 9: Project Directory
Page 10: Project Directory
Page 11: Project Directory
Page 12: Project Directory
Page 13: Project Directory
Page 14: Project Directory
Page 15: Project Directory
Page 16: Project Directory
Page 17: Project Directory
Page 18: Project Directory

LUMINAIRE SCHEDULE

Symbol Label Qty File Lumens LLF WattsCatalog Number Description Lamp

W1 8 WST_2_42TRT

_MD.ies

3200 1.00 93

S1 3 KAD_175M_R3

_(PULSE_STA

RT).ies

14400 1.00 208

WST 2/42TRT MD

ARCHITECTURAL

SCONCE WITH MEDIUM

THROW DISTRIBUTION

WITH CLEAR, FLAT

GLASS LENS. MEETS

THE 'NIGHTTIME

FRIENDLY' CRITERIA

TWO 42-WATT TRIPLE

TUBE COMPACT

FLUORESCENT,

HORIZONTAL POSITION.

KAD 175M R3

(PULSE START)

Area Luminaire, 175W

MH, R3 Reflector, Full

Cutoff MEETS THE

'NIGHTTIME FRIENDLY'

CRITERIA

ONE 175-WATT CLEAR

BT-28 METAL HALIDE,

HORIZONTAL POSITION.

STATISTICS

Description Symbol Avg Max Min Max/Min Avg/Min

Calc Zone #3 3.1 fc 21.5 fc 0.0 fc N / A N / A

Page 19: Project Directory

Children's PracticeWaiting

104

Adult PracticeWaiting

101

Reception102

Kids' Area105

Patient Restroom106

Open Bay108

Quiet Room 1110

Quiet Room 2111

Sterilization113

Mechanical115

Med Gas114

Treatment Hallway116

Lab112

Consult107

Operatory 2117

Operatory 1118

Hygiene119

IT Closet120

Adult PracticeHallway

121

Restroom122

Staff Room123

Doctors' Office124

Imaging Station109

Reception Hallway103

Page 20: Project Directory

Children's PracticeWaiting

104

Adult PracticeWaiting

101

Reception102

Kids' Area105

Patient Restroom106

Open Bay108

Quiet Room 1110

Quiet Room 2111

Sterilization113

Mechanical115

Med Gas114

Treatment Hallway116

Lab112

Consult107

Operatory 2117

Operatory 1118

Hygiene119

IT Closet120

Adult PracticeHallway

121

Restroom122

Staff Room123

Doctors' Office124

Imaging Station109

Reception Hallway103

Page 21: Project Directory
Page 22: Project Directory

METER

3-1/2" CONDUIT

3#500, 1#3G. IN

MAIN DS

400A

SEE GROUNDING DETAIL

2/E5.1. CONNECT PER N.E.C

NEW

3-1/2" CONDUIT

OVERHEAD OR UNDERGROUND SERVICE ENTRANCE

PER UTILITY AND SITE-SPECIFIC CONDITIONS WIRING

TO BE SIZED PER LOCAL CODE REQUIREMENT

(4)#500KCMIL, (1)#3G, (1)#3IG