9
Copyright 2019. These drawings are instruments of the Architect's service and the property of Design 3 Architecture, PC; and shall not be reproduced or used in any way, whatsoever, without the written permission of Design 3 Architecture, PC. c DWG. NAME: H:\WESTMORELAND COUNTY\2019-14 WMC COURTHHOUSE LOBBY CEILING REN\2019-14 CD DATE: 3/28/2019 3:50 PM MOD. BY: AZOTTOLA Door Number Section Mark Elevation Mark Sheet Number Detail Number Finish Tag Construction Note Room Identification PC 300 Oxford Drive Suite 120 Monroeville, PA 15146 TEL (412) 373-2220 FAX (412) 373-4571 www.d3a.com Storefront/Window Tag Masonry Step Tag XX Sheet Number Section Number 1 - XXX XXX X XXXXX XX List of Documents: Project Directory: Ceiling Lobby Renovation Westmoreland County Courthouse Annex 2N. Main St. Greensburg PA, 15601 N. MAIN ST. S. PENNSYLVANIA AVE. W. PITTSBURGH ST. W. OTTERMAN ST. S. MAPLE AVE. SITE Westmoreland County Att: Gary J. Vautard 2 N. Main St., Ste 15 Greensburg, PA 15601 724-853-4623 (p) 724-830-3016 (f) [email protected] Bldg. North N Bldg. North N

Project Directory: List of Documents

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Project Directory: List of Documents

Copyright 2019.

These drawings are instruments of the Architect's service and

the property of Design 3 Architecture, PC; and shall not be

reproduced or used in any way, whatsoever, without the written

permission of Design 3 Architecture, PC.

c

DW

G. N

AME:

H:\W

ESTM

OR

ELAN

D C

OU

NTY

\201

9-14

WM

C C

OU

RTH

HO

USE

LO

BBY

CEI

LIN

G R

EN\2

019-

14 C

DD

ATE:

3/28

/201

9 3:

50 P

MM

OD

. BY:

AZO

TTO

LA

Door Number

Section

Mark

Elevation

Mark

Sheet

Number

Detail

Number

Finish Tag

Construction

Note

Room

Identification

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

Storefront/Window

Tag

Masonry Step

Tag

XX

Sheet

Number

Section

Number

1

-

XXX

XXX

X

XXXXX

XX

List of Documents:Project Directory:

Ceiling Lobby Renovation

Westmoreland County Courthouse Annex

2N. Main St.

Greensburg PA, 15601

N. MAIN ST.

S. PENNSYLVANIA AVE.

W. P

IT

TS

BU

RG

H S

T.

W. O

TT

ER

MA

N S

T.

S. MAPLE AVE.

SITE

Westmoreland County

Att: Gary J. Vautard

2 N. Main St., Ste 15

Greensburg, PA 15601

724-853-4623 (p)

724-830-3016 (f)

[email protected]

Bldg. North

N

Bldg. North

N

AutoCAD SHX Text
%%UABBREVIATIONS
AutoCAD SHX Text
ADJ. ADJUSTABLE ADJUSTABLE A.F.F. ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR ALT. ALTERNATE ALTERNATE B/C BOTTOM OF CURB BOTTOM OF CURB BLDG. BUILDING BUILDING BKHD. BULKHEAD BULKHEAD BLKG. BLOCKING BLOCKING C.J. MASONRY CONTROL JOINT MASONRY CONTROL JOINT CONC. CONCRETE CONCRETE CONT. CONTINUOUS CONTINUOUS DED. DEDICATED DEDICATED DIA. DIAMETER DIAMETER DWG. DRAWING DRAWING D.V. DRYER VENT DRYER VENT EQ. EQUAL EQUAL F.D. FLOOR DRAIN FLOOR DRAIN F.R.-TR. FIRE RETARDANT-TREATED FIRE RETARDANT-TREATED GAL. GALLON GALLON GALV. GALVANIZED GALVANIZED G.P.D.W. GYPSUM DRY WALL GYPSUM DRY WALL H.D. HEAVY DUTY HEAVY DUTY H.M. HOLLOW METAL HOLLOW METAL HOR. HORIZONTAL HORIZONTAL K.D. KNOCK DOWN KNOCK DOWN L.L.H. LONG LEG HORIZONTAL LONG LEG HORIZONTAL L.L.V. LONG LEG VERTICAL LONG LEG VERTICAL L.P. LOW PRESSURE LOW PRESSURE MAX. MAXIMUM MAXIMUM MIN. MINIMUM MINIMUM MTD. MOUNTED MOUNTED O.C. ON CENTER ON CENTER O.D. OUTSIDE DIAMETER OUTSIDE DIAMETER OH. OVERHEAD OVERHEAD OPP. OPPOSITE OPPOSITE P.LAM. PLASTIC LAMINATE PLASTIC LAMINATE PNTD. PAINTED PAINTED P.T. PRESSURE TREATED PRESSURE TREATED REQ'D. REQUIRED REQUIRED R. RADIUS RADIUS R.C.B. RESILIENT COVE BASE RESILIENT COVE BASE R.O. ROUGH OPENING ROUGH OPENING R.S.B. RESILIENT STRAIGHT BASE RESILIENT STRAIGHT BASE S.F. SQUARE FOOT SQUARE FOOT SIM. SIMILAR SIMILAR S.S. STAINLESS STEEL STAINLESS STEEL S.S.V. SOLID SURFACE VENEER SOLID SURFACE VENEER T/C TOP OF CURB TOP OF CURB T.B.D. TO BE DETERMINED TO BE DETERMINED T.S. TUBE STEEL TUBE STEEL TYP. TYPICAL TYPICAL U.N.O. UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE VERT. VERTICAL VERTICAL WD. WOOD WOOD W.M.G. WIRE MANAGEMENT GROMMET WIRE MANAGEMENT GROMMET W.W.F. WIRE WELDED FABRICWIRE WELDED FABRIC
AutoCAD SHX Text
%%USYMBOLS
AutoCAD SHX Text
%%UXXXXX
AutoCAD SHX Text
Scale: Not to Scale
AutoCAD SHX Text
%%uSITE LOCATION MAP
AutoCAD SHX Text
Architectural Drawings
AutoCAD SHX Text
Electrical Drawings
AutoCAD SHX Text
E101 Lighting Plan Base Bid E102 Lighting Plan Alternate #1 E103 Lighting Plan Alternate #2 E104 Electrical Notes
AutoCAD SHX Text
A000 Cover Sheet Cover Sheet A101 Reflected Ceiling Demo Plan Reflected Ceiling Demo Plan A102 Reflected Ceiling Plan-Base Bid A103 Reflected Ceiling Plan-Alternate. #1 A104 Reflected Ceiling Plan-Alternate. #2
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County Couthouse
AutoCAD SHX Text
Permit Drawings
AutoCAD SHX Text
03/28/2019
AutoCAD SHX Text
JOB #: 2019-14
AutoCAD SHX Text
Owner:
AutoCAD SHX Text
%%uBUILDING KEY PLAN
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
SCOPE OF WORK
AutoCAD SHX Text
%%UCOURTHOUSE
AutoCAD SHX Text
%%UPLAZA
AutoCAD SHX Text
%%UW. OTTERMAN STREET
AutoCAD SHX Text
%%USOUTH MAIN STREET
AutoCAD SHX Text
W. PITTSBURGH STREET
AutoCAD SHX Text
N. PENNSYLVANIA AVENUE
AutoCAD SHX Text
%%UANNEX
AutoCAD SHX Text
Electrical Engineer:
AutoCAD SHX Text
Architect:
AutoCAD SHX Text
%%UPedicone Engineering Consultants, PC
AutoCAD SHX Text
4257 Gibsonia Road Gibsonia, Pa. 15044 Tel: 724-443-5400 Contact: Mr. Guy T. Pedicone P.E. Email: [email protected]
AutoCAD SHX Text
%%UDesign 3 Architecture, PC
AutoCAD SHX Text
300 Oxford Drive Suite 120 Monroeville, PA 15146 Tel: 412-373-2220 Fax: 412-373-4571 Contact: William A Snyder,AIA Email: [email protected]
AutoCAD SHX Text
427 Worthington Dr. Mars, PA 16046 Tel: 724-741-0290 Fax: 724-741-0289 Contact: Barry Beck Esq. P.E Email: [email protected]
AutoCAD SHX Text
%%UBeck Consulting LLC
Page 2: Project Directory: List of Documents

SD

SD

SD

SD

SD

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

H:\W

ESTM

OR

ELAN

D C

OU

NTY

\201

9-14

WM

C C

OU

RTH

HO

USE

LO

BBY

CEI

LIN

G R

EN\2

019-

14 C

DD

ATE:

3/28

/201

9 3:

51 P

MM

OD

. BY:

AZO

TTO

LA

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

1

Bldg. North

N

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
REMOVE EXISTING CEILING SYSTME AND RECESSED LIGHTS THROUGHOUT
AutoCAD SHX Text
REMOVE ALL EXISTING TRACK LIGHTS IN BULKHEAD
AutoCAD SHX Text
REPAIR, PATCH AND PAINT BULKHEAD TO MATCH ADJACENT
AutoCAD SHX Text
EXISTING PANEL SYSTEM TO BE DEMOLISHED EXISTING RECESSED DOWN LIGHT TO BE REMOVED, SEE ELECTRICAL DAWIINGS EXISTING SMOKE DETECTOR TO REMAIN, PROTECT AND REUSE EXISTING SPEAKER TO REMAIN, PROTECT AND REUSE
AutoCAD SHX Text
CEILING DEMO. LEGEND
AutoCAD SHX Text
S
AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Reflected Ceiling Demo Plan
AutoCAD SHX Text
2019-14
AutoCAD SHX Text
A101
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UREFLECTED CEILING DEMO PLAN
Page 3: Project Directory: List of Documents

SD

SD

SD

SD

SD

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

H:\W

ESTM

OR

ELAN

D C

OU

NTY

\201

9-14

WM

C C

OU

RTH

HO

USE

LO

BBY

CEI

LIN

G R

EN\2

019-

14 C

DD

ATE:

3/28

/201

9 3:

53 P

MM

OD

. BY:

AZO

TTO

LA

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

1

Bldg. North

N

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
RELOCATE NEW RECESSED LIGHT FIXTURE, CENTERED IN CEILING TILE TYP VERIFY WITH ARCHITECT FINAL LOCATION
AutoCAD SHX Text
NEW LINEAR LIGHTS FIXTURE SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
COFFER 2'X2' LAY-IN ACOUSTICAL CLG. (METHAPHORS AND ULTIMA SYSTEM)PANEL SUSPENDED IN WHITE T GRID
AutoCAD SHX Text
FIELD 24"X24"(ULTIMA) LAY IN CEILING TYP
AutoCAD SHX Text
EXISTING RECESSED DOWN LIGHT TO BE REMOVED, SEE ELECTRICAL DAWIINGS EXISTING SMOKE DETECTOR TO REMAIN, PROTECT AND REUSE EXISTING SPEAKER TO REMAIN, PROTECT AND REUSE NEW LINEAR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
CEILING FIXTURE LEGEND
AutoCAD SHX Text
S
AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Reflected Ceiling Plan
AutoCAD SHX Text
Base Bid
AutoCAD SHX Text
2019-34
AutoCAD SHX Text
A102
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UREFLECTED CEILING PLAN-BASE BID
Page 4: Project Directory: List of Documents

SD

SD

SD

SD

SD

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

H:\W

ESTM

OR

ELAN

D C

OU

NTY

\201

9-14

WM

C C

OU

RTH

HO

USE

LO

BBY

CEI

LIN

G R

EN\2

019-

14 C

DD

ATE:

3/28

/201

9 3:

53 P

MM

OD

. BY:

AZO

TTO

LA

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

1

Bldg. North

N

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
ANGLED PATTERN 4'X4' LAY-IN ACOUSTICAL CLG.WITH GRAY GRID
AutoCAD SHX Text
RELOCATE NEW RECESSED LIGHT FIXTURE, CENTERED IN CEILING TILE TYP. VERIFY WITH ARCHITECT FINAL LOCATION
AutoCAD SHX Text
FIELD 24"X24"(ULTIMA) LAY IN CEILING WITH WHITE GRID
AutoCAD SHX Text
NEW LINEAR LIGHTS FIXTURE SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
EXISTING RECESSED DOWN LIGHT TO BE REMOVED, SEE ELECTRICAL DAWIINGS EXISTING SMOKE DETECTOR TO REMAIN, PROTECT AND REUSE EXISTING SPEAKER TO REMAIN, PROTECT AND REUSE NEW LINEAR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
CEILING FIXTURE LEGEND
AutoCAD SHX Text
S
AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Reflected Ceiling Plan
AutoCAD SHX Text
Alternate #1
AutoCAD SHX Text
2019-34
AutoCAD SHX Text
A103
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UREFLECTED CEILING PLAN ALTERNATE #1
Page 5: Project Directory: List of Documents

SD

SD

SD

SD

SD

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

H:\W

ESTM

OR

ELAN

D C

OU

NTY

\201

9-14

WM

C C

OU

RTH

HO

USE

LO

BBY

CEI

LIN

G R

EN\2

019-

14 C

DD

ATE:

3/28

/201

9 3:

53 P

MM

OD

. BY:

AZO

TTO

LA

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

1

Bldg. North

N

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
RELOCATE NEW RECESSED LIGHT FIXTURE, CENTERED IN CEILING TILE TYP VERIFY WITH ARCHITECT FINAL LOCATION
AutoCAD SHX Text
2'X4' LAY-IN ACOUSTICAL CLG. PANEL SUSPENDED IN WHITE T-GRID SECOND LOOK ONE 8 GRID LOOK (DUNA)
AutoCAD SHX Text
NEW LINEAR LIGHTS FIXTURE SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
EXISTING RECESSED DOWN LIGHT TO BE REMOVED, SEE ELECTRICAL DAWIINGS EXISTING SMOKE DETECTOR TO REMAIN, PROTECT AND REUSE EXISTING SPEAKER TO REMAIN, PROTECT AND REUSE NEW LINEAR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
CEILING FIXTURE LEGEND
AutoCAD SHX Text
S
AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Reflected Ceiling Plan
AutoCAD SHX Text
Alternate #2
AutoCAD SHX Text
2019-14
AutoCAD SHX Text
A104
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UREFLECTED CEILING PLAN ALTERNATE #2
Page 6: Project Directory: List of Documents

EXISTING 480/277V

ELECTRICAL PANEL.

EXISTING 277V 20/1 CIRCUITS

#1,2, & 3 FEED EXISTING

LOBBY LIGHTING. REUSE

CIRCUITS TO FEED NEW LED

LIGHTING IN LOBBY.

LOBBY

SD

SD

SD

SD

B B B B B B

B

A2

A2

A1 A1

A2

A2

A2A1 A1

A1

A1

A1 A1 A1

A1A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1 A1

A1

A1 A1

A1

A1 A1

A1

DEMO EXISTING

FLOOD LIGHTS AT

BULKHEAD (TYP.)

NEW LINEAR LED

LIGHTS AT

BULHHEAD (TYP.)

DEMO EXISTING DOWNLIGHTS

AND REPLACE WITH NEW LED

DOWNLIGHTS. LOCATE NEW

DOWNLIGHTS AS REQUIRED

FOR NEW CEILING LAYOUT.

(TYP.)

TO EXISTING 20/1, 277V CIRCUIT

FEEDING EXISTING LIGHTING IN THIS

AREA. TOTAL WATTAGE OF ALL NEW

LIGHTING IS 2,871.5

VERIFY EXACT

LOCATION AND

CONFIGURATION OF

LIGHTING CONTROLS

WITH ARCHITECT.

D

B B B B B B

B

B

B

B

B

B

B

D

D

B B

B

LOCATE AND INSTALL NEW

RECESSED LED LIGHT

FIXTURE, CENTERED IN

CEILING TILE (TYP.)

VERIFY FINAL LOCATION

WITH ARCHITECT

DEMO EXISTING DOWNLIGHTS

(TYP.)

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

P:\2

019

CU

RR

ENT\

2019

2927

WC

CH

AN

NEX

LTG

\E-1

01D

ATE:

3/2

8/20

19 4

:02

PMM

OD

. BY:

DIA

NE

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

1

LIGHTING FIXTURE NOTES (AS APPLICABLE):

1. ALL LED LAMPS SHALL BE 3500° KELVIN WITH A MINIMUM C.R.I. OF 80 UNLESS INDICATED OTHERWISE.

2. E.C. SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHTING PLACEMENT.

3. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO REVIEW THE ROOM FINISH SCHEDULES OF THE

GENERAL CONSTRUCTION DRAWING, AND THE SPECIFICATION DETAILS OF DIVISION 12 FOR THE TYPES

OF CEILING CONSTRUCTIONS ANTICIPATED IN VARIOUS AREAS. THIS CONTRACTOR SHALL DETERMINE

FROM THIS REVIEW, ALL LIGHTING FIXTURE VARIATIONS, ACCESSORIES, AND/OR MODIFICATIONS THAT

WILL BE REQUIRED FOR EACH FIXTURE TYPE TO INSURE PROPER INSTALLATION AND SUPPORT

COMPATIBILITY WITH THE CEILING AND/OR CASEWORK CONSTRUCTIONS IN WHICH EACH FIXTURE TYPE

IS TO BE INSTALLED. THIS CONTRACTOR SHALL FURTHER VERIFY WITH THE GENERAL CONTRACTOR, THE

DETAILS OF THE FINAL SET OF APPROVED SHOP DRAWINGS OF CEILING CONSTRUCTION. THIS

CONTRACTOR SHALL ORDER LIGHTING FIXTURES THAT ARE COMPLETELY COMPATIBLE WITH THESE

FINAL SHOP DRAWINGS. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR LIGHTING FIXTURE

MODIFICATIONS OR CHANGES RESULTING FROM THE FAILURE OF THIS CONTRACTOR TO COORDINATE

THE LIGHTING FIXTURES WITH THE FINAL CEILING CONSTRUCTION SHOP DRAWINGS.

4. LED DRIVERS SHALL BE SOLID STATE AND ACCEPT 120 THROUGH 277 VAC AT 60 HZ INPUT. THE LED

LIGHT SOURCE SHALL BE FULLY DIMMABLE (1% MAXIMUM LOW LEVEL) AND CAPABLE OF "FULL OFF"

WITH USE OF COMPATIBLE DIMMER SWITCH DESIGNATED FOR LOW VOLTAGE LOADS. PROVIDE CLASS 1

WIRING, TWISTED JACKETED PAIR OF #16 AWG SOLID TYPE TFN CONDUCTORS FOR CONTROL OF 0-10V

CIRCUIT REQUIREMENTS IN ADDITION TO THE BRANCH CIRCUIT CONDUCTORS.

5. CONTRACTOR TO VERIFY THAT ALL LIGHTING FIXTURES TO BE 100% COMPATIBLE WITH CEILING

ARRANGEMENT BEING INSTALLED.

6. LIGHTING CIRCUIT DESIGNATIONS ARE SHOWN FOR CLARIFICATION OF CIRCUIT TO BE UTILIZED, AND

DO NOT NECESSARILY REPRESENT THE NUMBER OF THE EXISTING CIRCUIT THAT IS TO BE INTERCEPTED

AND UTILIZED. EXACT CIRCUIT CONFIGURATIONS ARE TO BE DETERMINED AND COORDINATED IN FIELD.

2

FIXTURE ID VOLTAGE MOUNTING DESCRIPTION

A1

B

LIGHT FIXTURE SCHEDULE

6" ROUND LED RECESSED DOWNLIGHT, 5 YEAR LIMITED WARRANTY

CEILING

RECESSED

MVOLT

DESIGNATION

LAMP CATALOG NUMBER

55.5 WATT

CRI 80

LED LIGHT ENGINE

3500K

4922 LUMENS

LITHONIA #

LDN6-35/50-LO6WR-LSS-MVOLT-GZ10

LINEAR LED WALL GRAZER, EXTRUDED ALUMINUM HOUSING, FLAT

LENS, POWDER-COATED FINISH, 5 YEAR LIMITED WARRANTY

BULKHEAD

SURFACE

MVOLT

7 WATT/FOOT

CRI 80

LED LIGHT ENGINE

3500K

811 LUMENS/FOOT

INSIGHT LIGHTING #

PGM-7-35K-30X60-SM-48-UNV-DIM-MG

NOTE: COORDINATE, FURNISH AND INSTALL ALL REQUIRED ACCESSORIES FOR A COMPLETE LIGHTING SYSTEM. ENSURE

COMPATIBILITY OF DIMMER SWITCHES WITH LIGHT FIXTURES.

A2

6" ROUND LED RECESSED DOWNLIGHT, 5 YEAR LIMITED WARRANTY

CEILING

RECESSED

MVOLT

22.6 WATT

CRI 80

LED LIGHT ENGINE

3500K

2023 LUMENS

LITHONIA #

LDN6-35/20-LO6WR-LSS-MVOLT-GZ10

ELECTRICAL WIRING SIZE TO BE #12 AWG MINIMUM UNLESS NOTED

OTHERWISE.

NEW LED LIGHTING IS TO REPLACE OLD LIGHTING IN LOBBY AND

UPPER WALKWAY. NEW LED LIGHTING TO RE-USE EXISTING 277V 20/1

CIRCUITS FEEDING EXISTING LIGHTING. EXISTING LIGHTING FED FROM

EXISTING 277/480V ELECTRICAL PANEL ON 2ND FLOOR UTILIZES

CIRCUITS #1, #2, & #3. VERIFY.

WALL DIMMER SWITCH/PANEL FOR LED

LIGHTING FIXTURES.- 48" AFF TO THE

CENTER - ON/OFF/DIMMING SCHEME AND

LOCATION TO BE DETERMINED AS PER

PARTICULAR ROOM REQUIREMENTS.

D

2'X2' LAY-IN ACOUSTICAL CLG. PANEL

SUSPENDED IN WHITE T-GRID.

NEW LED RECESSED LED DOWN LIGHT

NEW SURFACE MOUNTED LED WALL

GRAZER TYPE.

SD

S

EXISTING SMOKE DETECTOR TO REMAIN.

PROTECT AND REUSE.

EXISTING SPEAKER TO REMAIN. PROTECT

AND REUSE.

SWITCHED CIRCUIT - LIGHTING

UNSWITCHED CIRCUIT - LIGHTING

EXISTING RECESSED LED DOWN LIGHT TO

BE REMOVED.

A1, A2

B

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
COFFER 2'X2' LAY-IN ACOUSTICAL CLG. (METHAPHORS AND ULTIMA SYSTEM)PANEL SUSPENDED IN WHITE T GRID
AutoCAD SHX Text
FIELD 24"X24"(ULTIMA) LAY IN CEILING TYP
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Lighting Plan
AutoCAD SHX Text
Base Bid
AutoCAD SHX Text
2019-34
AutoCAD SHX Text
E101
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%ULIGHTING PLAN - BASE BID
AutoCAD SHX Text
SCALE: APPROX. 1/16"=1'-0"
AutoCAD SHX Text
%%UPARTIAL SECOND FLOOR PLAN
AutoCAD SHX Text
CEILING LEGEND
AutoCAD SHX Text
S
Page 7: Project Directory: List of Documents

EXISTING 480/277V

ELECTRICAL PANEL.

EXISTING 277V 20/1 CIRCUITS

#1,2, & 3 FEED EXISTING

LOBBY LIGHTING. REUSE

CIRCUITS TO FEED NEW LED

LIGHTING IN LOBBY.

LOBBY

SD

SD

SD

SD

B B B B B B

B

A2

A2

A1 A1

A2

A2

A2A1 A1

A1

A1

A1 A1 A1

A1A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

DEMO EXISTING

FLOOD LIGHTS AT

BULKHEAD (TYP.)

NEW LINEAR LED

LIGHTS AT

BULHHEAD (TYP.)

D

B B B B B B

B

B

B

B

B

B

B

D

D

LOCATE AND INSTALL NEW

RECESSED LED LIGHT

FIXTURE, CENTERED IN

CEILING TILE (TYP.)

VERIFY FINAL LOCATION

WITH ARCHITECT

DEMO EXISTING DOWNLIGHTS

(TYP.)

DEMO EXISTING DOWNLIGHTS

AND REPLACE WITH NEW LED

DOWNLIGHTS. LOCATE NEW

DOWNLIGHTS AS REQUIRED

FOR NEW CEILING LAYOUT.

(TYP.)

B B

B

A1 A1 A1 A1 A1 A1

VERIFY EXACT

LOCATION AND

CONFIGURATION

OF LIGHTING

CONTROLS WITH

ARCHITECT.

TO EXISTING 20/1, 277V CIRCUIT

FEEDING EXISTING LIGHTING IN THIS

AREA. TOTAL WATTAGE OF ALL NEW

LIGHTING IS 2,871.5

A1

A1

A1A1

A1

A1

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

P:\2

019

CU

RR

ENT\

2019

2927

WC

CH

AN

NEX

LTG

\E-1

01D

ATE:

3/2

8/20

19 4

:02

PMM

OD

. BY:

DIA

NE

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

1

LIGHTING FIXTURE NOTES (AS APPLICABLE):

1. ALL LED LAMPS SHALL BE 3500° KELVIN WITH A MINIMUM C.R.I. OF 80 UNLESS INDICATED OTHERWISE.

2. E.C. SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHTING PLACEMENT.

3. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO REVIEW THE ROOM FINISH SCHEDULES OF THE

GENERAL CONSTRUCTION DRAWING, AND THE SPECIFICATION DETAILS OF DIVISION 12 FOR THE TYPES

OF CEILING CONSTRUCTIONS ANTICIPATED IN VARIOUS AREAS. THIS CONTRACTOR SHALL DETERMINE

FROM THIS REVIEW, ALL LIGHTING FIXTURE VARIATIONS, ACCESSORIES, AND/OR MODIFICATIONS THAT

WILL BE REQUIRED FOR EACH FIXTURE TYPE TO INSURE PROPER INSTALLATION AND SUPPORT

COMPATIBILITY WITH THE CEILING AND/OR CASEWORK CONSTRUCTIONS IN WHICH EACH FIXTURE TYPE

IS TO BE INSTALLED. THIS CONTRACTOR SHALL FURTHER VERIFY WITH THE GENERAL CONTRACTOR, THE

DETAILS OF THE FINAL SET OF APPROVED SHOP DRAWINGS OF CEILING CONSTRUCTION. THIS

CONTRACTOR SHALL ORDER LIGHTING FIXTURES THAT ARE COMPLETELY COMPATIBLE WITH THESE

FINAL SHOP DRAWINGS. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR LIGHTING FIXTURE

MODIFICATIONS OR CHANGES RESULTING FROM THE FAILURE OF THIS CONTRACTOR TO COORDINATE

THE LIGHTING FIXTURES WITH THE FINAL CEILING CONSTRUCTION SHOP DRAWINGS.

4. LED DRIVERS SHALL BE SOLID STATE AND ACCEPT 120 THROUGH 277 VAC AT 60 HZ INPUT. THE LED

LIGHT SOURCE SHALL BE FULLY DIMMABLE (1% MAXIMUM LOW LEVEL) AND CAPABLE OF "FULL OFF"

WITH USE OF COMPATIBLE DIMMER SWITCH DESIGNATED FOR LOW VOLTAGE LOADS. PROVIDE CLASS 1

WIRING, TWISTED JACKETED PAIR OF #16 AWG SOLID TYPE TFN CONDUCTORS FOR CONTROL OF 0-10V

CIRCUIT REQUIREMENTS IN ADDITION TO THE BRANCH CIRCUIT CONDUCTORS.

5. CONTRACTOR TO VERIFY THAT ALL LIGHTING FIXTURES TO BE 100% COMPATIBLE WITH CEILING

ARRANGEMENT BEING INSTALLED.

6. LIGHTING CIRCUIT DESIGNATIONS ARE SHOWN FOR CLARIFICATION OF CIRCUIT TO BE UTILIZED, AND

DO NOT NECESSARILY REPRESENT THE NUMBER OF THE EXISTING CIRCUIT THAT IS TO BE INTERCEPTED

AND UTILIZED. EXACT CIRCUIT CONFIGURATIONS ARE TO BE DETERMINED AND COORDINATED IN FIELD.

2

FIXTURE ID VOLTAGE MOUNTING DESCRIPTION

A1

B

LIGHT FIXTURE SCHEDULE

6" ROUND LED RECESSED DOWNLIGHT, 5 YEAR LIMITED WARRANTY

CEILING

RECESSED

MVOLT

DESIGNATION

LAMP CATALOG NUMBER

55.5 WATT

CRI 80

LED LIGHT ENGINE

3500K

4922 LUMENS

LITHONIA #

LDN6-35/50-LO6WR-LSS-MVOLT-GZ10

LINEAR LED WALL GRAZER, EXTRUDED ALUMINUM HOUSING, FLAT

LENS, POWDER-COATED FINISH, 5 YEAR LIMITED WARRANTY

BULKHEAD

SURFACE

MVOLT

7 WATT/FOOT

CRI 80

LED LIGHT ENGINE

3500K

811 LUMENS/FOOT

INSIGHT LIGHTING #

PGM-7-35K-30X60-SM-48-UNV-DIM-MG

NOTE: COORDINATE, FURNISH AND INSTALL ALL REQUIRED ACCESSORIES FOR A COMPLETE LIGHTING SYSTEM. ENSURE

COMPATIBILITY OF DIMMER SWITCHES WITH LIGHT FIXTURES.

A2

6" ROUND LED RECESSED DOWNLIGHT, 5 YEAR LIMITED WARRANTY

CEILING

RECESSED

MVOLT

22.6 WATT

CRI 80

LED LIGHT ENGINE

3500K

2023 LUMENS

LITHONIA #

LDN6-35/20-LO6WR-LSS-MVOLT-GZ10

WALL DIMMER SWITCH/PANEL FOR LED

LIGHTING FIXTURES.- 48" AFF TO THE

CENTER - ON/OFF/DIMMING SCHEME AND

LOCATION TO BE DETERMINED AS PER

PARTICULAR ROOM REQUIREMENTS.

D

4'X4' LAY-IN ACOUSTICAL CLG. PANEL

SUSPENDED IN WHITE T-GRID.

NEW LED RECESSED LED DOWN LIGHT

NEW SURFACE MOUNTED LED WALL

GRAZER TYPE.

ELECTRICAL WIRING SIZE TO BE #12 AWG MINIMUM UNLESS NOTED

OTHERWISE.

SD

S

EXISTING SMOKE DETECTOR TO REMAIN.

PROTECT AND REUSE.

EXISTING SPEAKER TO REMAIN. PROTECT

AND REUSE.

NEW LED LIGHTING IS TO REPLACE OLD LIGHTING IN LOBBY AND

UPPER WALKWAY. NEW LED LIGHTING TO RE-USE EXISTING 277V 20/1

CIRCUITS FEEDING EXISTING LIGHTING. EXISTING LIGHTING FED FROM

EXISTING 277/480V ELECTRICAL PANEL ON 2ND FLOOR UTILIZES

CIRCUITS #1, #2, & #3. VERIFY.

SWITCHED CIRCUIT - LIGHTING

UNSWITCHED CIRCUIT - LIGHTING

EXISTING RECESSED LED DOWN LIGHT TO

BE REMOVED.

A1, A2

B

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
ANGLED PATTERN 4'X4' LAY-IN ACOUSTICAL CLG.WITH GRAY GRID
AutoCAD SHX Text
FIELD 24"X24"(ULTIMA) LAY IN CEILING WITH WHITE GRID
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Lighting Plan
AutoCAD SHX Text
Alternate #1
AutoCAD SHX Text
2019-34
AutoCAD SHX Text
E102
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%ULIGHTING PLAN - ALTERNATE #1
AutoCAD SHX Text
SCALE: APPROX. 1/16"=1'-0"
AutoCAD SHX Text
%%UPARTIAL SECOND FLOOR PLAN
AutoCAD SHX Text
CEILING LEGEND
AutoCAD SHX Text
S
Page 8: Project Directory: List of Documents

EXISTING 480/277V

ELECTRICAL PANEL.

EXISTING 277V 20/1 CIRCUITS

#1,2, & 3 FEED EXISTING

LOBBY LIGHTING. REUSE

CIRCUITS TO FEED NEW LED

LIGHTING IN LOBBY.

LOBBY

SD

SD

SD

SD

B B B B B B

B

A2

A2

A2

A2

A2

A1 A1

A1

A1

A1

A1

A1 A1

A1

A1 A1

A1

A1 A1

A1

DEMO EXISTING

FLOOD LIGHTS AT

BULKHEAD (TYP.)

NEW LINEAR LED

LIGHTS AT

BULHHEAD (TYP.)

DEMO EXISTING DOWNLIGHTS

AND REPLACE WITH NEW LED

DOWNLIGHTS. LOCATE NEW

DOWNLIGHTS AS REQUIRED

FOR NEW CEILING LAYOUT.

(TYP.)

TO EXISTING 20/1, 277V CIRCUIT

FEEDING EXISTING LIGHTING IN THIS

AREA. TOTAL WATTAGE OF ALL NEW

LIGHTING IS 2,871.5

VERIFY EXACT

LOCATION AND

CONFIGURATION

OF LIGHTING

CONTROLS WITH

ARCHITECT.

D

B B B B B B

B

B

B

B

B

B

B

D

D

A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

B B

B

B

LOCATE AND INSTALL NEW

RECESSED LED LIGHT

FIXTURE, CENTERED IN

CEILING TILE (TYP.)

VERIFY FINAL LOCATION

WITH ARCHITECT

DEMO EXISTING DOWNLIGHTS

(TYP.)

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

P:\2

019

CU

RR

ENT\

2019

2927

WC

CH

AN

NEX

LTG

\E-1

01D

ATE:

3/2

8/20

19 4

:02

PMM

OD

. BY:

DIA

NE

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

1

LIGHTING FIXTURE NOTES (AS APPLICABLE):

1. ALL LED LAMPS SHALL BE 3500° KELVIN WITH A MINIMUM C.R.I. OF 80 UNLESS INDICATED OTHERWISE.

2. E.C. SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHTING PLACEMENT.

3. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO REVIEW THE ROOM FINISH SCHEDULES OF THE

GENERAL CONSTRUCTION DRAWING, AND THE SPECIFICATION DETAILS OF DIVISION 12 FOR THE TYPES

OF CEILING CONSTRUCTIONS ANTICIPATED IN VARIOUS AREAS. THIS CONTRACTOR SHALL DETERMINE

FROM THIS REVIEW, ALL LIGHTING FIXTURE VARIATIONS, ACCESSORIES, AND/OR MODIFICATIONS THAT

WILL BE REQUIRED FOR EACH FIXTURE TYPE TO INSURE PROPER INSTALLATION AND SUPPORT

COMPATIBILITY WITH THE CEILING AND/OR CASEWORK CONSTRUCTIONS IN WHICH EACH FIXTURE TYPE

IS TO BE INSTALLED. THIS CONTRACTOR SHALL FURTHER VERIFY WITH THE GENERAL CONTRACTOR, THE

DETAILS OF THE FINAL SET OF APPROVED SHOP DRAWINGS OF CEILING CONSTRUCTION. THIS

CONTRACTOR SHALL ORDER LIGHTING FIXTURES THAT ARE COMPLETELY COMPATIBLE WITH THESE

FINAL SHOP DRAWINGS. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR LIGHTING FIXTURE

MODIFICATIONS OR CHANGES RESULTING FROM THE FAILURE OF THIS CONTRACTOR TO COORDINATE

THE LIGHTING FIXTURES WITH THE FINAL CEILING CONSTRUCTION SHOP DRAWINGS.

4. LED DRIVERS SHALL BE SOLID STATE AND ACCEPT 120 THROUGH 277 VAC AT 60 HZ INPUT. THE LED

LIGHT SOURCE SHALL BE FULLY DIMMABLE (1% MAXIMUM LOW LEVEL) AND CAPABLE OF "FULL OFF"

WITH USE OF COMPATIBLE DIMMER SWITCH DESIGNATED FOR LOW VOLTAGE LOADS. PROVIDE CLASS 1

WIRING, TWISTED JACKETED PAIR OF #16 AWG SOLID TYPE TFN CONDUCTORS FOR CONTROL OF 0-10V

CIRCUIT REQUIREMENTS IN ADDITION TO THE BRANCH CIRCUIT CONDUCTORS.

5. CONTRACTOR TO VERIFY THAT ALL LIGHTING FIXTURES TO BE 100% COMPATIBLE WITH CEILING

ARRANGEMENT BEING INSTALLED.

6. LIGHTING CIRCUIT DESIGNATIONS ARE SHOWN FOR CLARIFICATION OF CIRCUIT TO BE UTILIZED, AND

DO NOT NECESSARILY REPRESENT THE NUMBER OF THE EXISTING CIRCUIT THAT IS TO BE INTERCEPTED

AND UTILIZED. EXACT CIRCUIT CONFIGURATIONS ARE TO BE DETERMINED AND COORDINATED IN FIELD.

2

FIXTURE ID VOLTAGE MOUNTING DESCRIPTION

A1

B

LIGHT FIXTURE SCHEDULE

6" ROUND LED RECESSED DOWNLIGHT, 5 YEAR LIMITED WARRANTY

CEILING

RECESSED

MVOLT

DESIGNATION

LAMP CATALOG NUMBER

55.5 WATT

CRI 80

LED LIGHT ENGINE

3500K

4922 LUMENS

LITHONIA #

LDN6-35/50-LO6WR-LSS-MVOLT-GZ10

LINEAR LED WALL GRAZER, EXTRUDED ALUMINUM HOUSING, FLAT

LENS, POWDER-COATED FINISH, 5 YEAR LIMITED WARRANTY

BULKHEAD

SURFACE

MVOLT

7 WATT/FOOT

CRI 80

LED LIGHT ENGINE

3500K

811 LUMENS/FOOT

INSIGHT LIGHTING #

PGM-7-35K-30X60-SM-48-UNV-DIM-MG

NOTE: COORDINATE, FURNISH AND INSTALL ALL REQUIRED ACCESSORIES FOR A COMPLETE LIGHTING SYSTEM. ENSURE

COMPATIBILITY OF DIMMER SWITCHES WITH LIGHT FIXTURES.

A2

6" ROUND LED RECESSED DOWNLIGHT, 5 YEAR LIMITED WARRANTY

CEILING

RECESSED

MVOLT

22.6 WATT

CRI 80

LED LIGHT ENGINE

3500K

2023 LUMENS

LITHONIA #

LDN6-35/20-LO6WR-LSS-MVOLT-GZ10

ELECTRICAL WIRING SIZE TO BE #12 AWG MINIMUM UNLESS NOTED

OTHERWISE.

NEW LED LIGHTING IS TO REPLACE OLD LIGHTING IN LOBBY AND

UPPER WALKWAY. NEW LED LIGHTING TO RE-USE EXISTING 277V 20/1

CIRCUITS FEEDING EXISTING LIGHTING. EXISTING LIGHTING FED FROM

EXISTING 277/480V ELECTRICAL PANEL ON 2ND FLOOR UTILIZES

CIRCUITS #1, #2, & #3. VERIFY.

WALL DIMMER SWITCH/PANEL FOR LED

LIGHTING FIXTURES.- 48" AFF TO THE

CENTER - ON/OFF/DIMMING SCHEME AND

LOCATION TO BE DETERMINED AS PER

PARTICULAR ROOM REQUIREMENTS.

D

NEW LED RECESSED LED DOWN LIGHT

NEW SURFACE MOUNTED LED WALL

GRAZER TYPE.

SD

S

EXISTING SMOKE DETECTOR TO REMAIN.

PROTECT AND REUSE.

EXISTING SPEAKER TO REMAIN. PROTECT

AND REUSE.

SWITCHED CIRCUIT - LIGHTING

UNSWITCHED CIRCUIT - LIGHTING

EXISTING RECESSED LED DOWN LIGHT TO

BE REMOVED.

A1, A2

B

2'X4' LAY-IN ACOUSTICAL CLG. PANEL

SUSPENDED IN WHITE T-GRID.

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
2'X4' LAY-IN ACOUSTICAL CLG. PANEL SUSPENDED IN WHITE T-GRID SECOND LOOK ONE 8 GRID LOOK (DUNA)
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Lighting Plan
AutoCAD SHX Text
Alternate #2
AutoCAD SHX Text
2019-34
AutoCAD SHX Text
E103
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%ULIGHTING PLAN - ALTERNATE #2
AutoCAD SHX Text
SCALE: APPROX. 1/16"=1'-0"
AutoCAD SHX Text
%%UPARTIAL SECOND FLOOR PLAN
AutoCAD SHX Text
CEILING LEGEND
AutoCAD SHX Text
S
Page 9: Project Directory: List of Documents

PC

300 Oxford DriveSuite 120Monroeville, PA 15146

TEL (412) 373-2220FAX (412) 373-4571

www.d3a.com

DW

G. N

AME:

P:\2

019

CU

RR

ENT\

2019

2927

WC

CH

AN

NEX

LTG

\E-1

01D

ATE:

3/2

8/20

19 4

:02

PMM

OD

. BY:

DIA

NE

Design 3 Architecture, PC All Rights Reserved

c

Copyright2019

GENERAL ELECTRICAL NOTES:

1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL

ELECTRICAL CODE, NFPA, UL BUILDING STANDARD AND ALL OTHER GOVERNING

AGENCIES HAVING JURISDICTION.

2. CONTRACTOR SHALL VISIT AND EXAMINE CAREFULLY THE AREAS AFFECTED BY

THIS WORK TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND WITH THE

DIFFICULTIES THAT WILL AFFECT THE EXECUTION OF THIS WORK. THIS VISIT SHALL

BE MADE PRIOR TO COMMENCING THE WORK OF THIS CONTRACT.

3. FURNISH AND INSTALL ALL REQUIRED CONDUITS, WIRES, CABLES, FITTINGS,

BOXES, HARDWARE, ETC. IN ORDER TO MAKE A COMPLETE ELECTRICAL SYSTEM

READY FOR OPERATION. PRIOR TO INSTALLATION, SUBMIT DRAWINGS FOR

APPROVAL SHOWING LAYOUT DETAILS. CONDUITS SHALL BE RUN IN THE LEAST

OBTRUSIVE MANNER POSSIBLE.

4. FINAL LOCATION OF ALL EQUIPMENT, AND ELECTRICS SERVING THEM, SHALL BE

DETERMINED IN THE FIELD AND SHALL BE INSTALLED AS DIRECTED BY THE

ENGINEER/ARCHITECT, AND OWNER'S SPECIALTY EQUIPMENT VENDOR.

5. WHERE STRUCTURAL OPENINGS ARE NOT AVAILABLE, THE CONTRACTOR SHALL

CORE DRILL OR CUT AND CHASE WALLS AND FLOORS AS REQUIRED TO PERMIT

PASSAGE OF CONDUITS AND RACEWAYS. AT COMPLETION OF INSTALLATIONS,

CONTRACTOR SHALL FILL IN AND WATERPROOF OR FIREPROOF, TO RATING OF

STRUCTURE PENETRATED, ALL OPENINGS WITH MATERIALS AS DIRECTED BY THE

ARCHITECT AND FINISH TO MATCH SURROUNDING AREAS. ALL OPENINGS SHALL BE

APPROVED BY THE ARCHITECT PRIOR TO DEMOLITION OR CORE DRILLING.

6. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT ONLY.

COORDINATE INSTALLATION WITH OTHER TRADES TO VERIFY THE ACTUAL SPACE

CONDITIONS. HEADROOM AND SPACE CONDITIONS ARE TO BE MAINTAINED. NO

ADDITIONAL PAYMENT WILL BE MADE FOR FAILURE TO COMPLY.

7. LIGHTING FIXTURES AND RECEPTACLES SHALL TYPICALLY NOT BE CONNECTED

TO THE SAME BRANCH CIRCUIT.

8. CIRCUITS SHALL BE BALANCED ON PHASE AT THEIR SUPPLY POINT AS EVENLY AS

POSSIBLE.

9. PROVIDE AND MAINTAIN NECESSARY TEMPORARY LIGHT AND POWER FOR ALL

TRADES, WHERE REQUIRED.

10. MINIMUM CONDUIT SIZE 3/4". MINIMUM WIRE SIZE SHALL BE #12 AWG. ALL

CONDUCTORS SHALL BE OF SOFT DRAWN COPPER HAVING A CONDUCTIVITY OF AT

LEAST 97%. ALL CONDUCTORS SHALL BE STRANDED 600 VOLT TYPE THWN-THHN

RATED MINIMUM 75 DEGREE C. ALL WIRE AND CABLE SHALL BE OF THE SINGLE

CONDUCTOR TYPE UNLESS OTHERWISE INDICATED, AND SHALL BE COLOR CODED

SO AS TO IDENTIFY EACH WIRE IN A RACEWAY OR CABLE.

11. EXACT LOCATION OF LIGHTING FIXTURES, SWITCHES AND ALL ELECTRICAL

DEVICES, SHALL BE VERIFIED WITH ARCHITECT OR OWNER IN FIELD.

12. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL RECEPTACLE LOCATIONS

WITH CASEWORK AND FURNITURE LAYOUT, REFER TO ARCHITECTURAL DRAWINGS

FOR ADDITIONAL INFORMATION OR COORDINATE WITH ARCHITECT IN FIELD.

13. BRANCH CIRCUITS SERVING ISOLATED GROUND RECEPTACLES SHALL INCLUDE

AN ADDITIONAL ISOLATED GROUND CONDUCTOR BACK TO THE PANEL SERVING

THEM.

14. PROVIDE NECESSARY RELOCATION OF LIGHTING FIXTURES, SWITCHES AND

ELECTRICAL DEVICES TO ACHIEVE FINAL DESIGN AS INDICATED ON ELECTRICAL,

HVAC, PLUMBING AND ARCHITECTURAL DRAWINGS.

15. WIRE SIZE FOR BRANCH CIRCUITS SHALL BE ADJUSTED TO COMPENSATE FOR

VOLTAGE DROP CALCULATIONS AS REQUIRED BY N.E.C. IF CIRCUIT RUN EXCEEDS

100 FT. IN WIRE LENGTH, NEXT WIRE SIZE (#10) SHALL BE USED.

16. ALL RACEWAYS FOR LIGHTING AND POWER USE, FOR BOTH FEEDERS AND

BRANCH CIRCUITS SHALL CONTAIN A SEPARATE EQUIPMENT GROUND WIRE WITH

GREEN INSULATION, THE MINIMUM SIZE OF WHICH SHALL BE IN ACCORDANCE WITH

ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. GROUND WIRE SHALL BE

CONTINUOUS FROM CIRCUIT ORIGINATION TO TERMINATION. ALL BRANCH CIRCUITS

SERVING 120V LOADS SHALL CONTAIN FULL SIZE SEPARATE NEUTRALS PER CIRCUIT.

SHARING OF NEUTRAL CONDUCTORS IS NOT PERMISSIBLE.

17. CONTRACTOR IS RESPONSIBLE FOR ANY CUTTING AND/OR PATCHING REQUIRED

BY ELECTRICAL WORK RESULTING FROM THE FAILURE OF THE ELECTRICIAN TO

INSTALL EMBEDDED OR BUILT-IN ITEMS AS AND WHEN REQUIRED.

18. CIRCUIT NUMBERS SHOWN ON FLOOR PLANS ARE INTENDED ONLY TO INDICATE

OUTLETS CIRCUITED TO EACH CORRESPONDING CIRCUIT AND SHALL NOT BE

CONSTRUED AS CIRCUIT NUMBERS IN THE PANEL.

19. ELECTRICAL CONTRACTOR SHALL PROVIDE PROPOSED PANEL SCHEDULES TO

BE REVIEWED BY ENGINEER.

20. DURING THE BIDDING PROCESS, ELECTRICAL CONTRACTOR SHALL REVIEW

DRAWINGS AND SPECIFICATIONS OF ALL OTHER TRADES (GENERAL, HVAC AND

PLUMBING). ALL ITEMS REQUIRING POWER INDICATED ON THESE DRAWINGS BUT

NOT INDICATED ON THE ELECTRICAL DRAWINGS SHALL BE CONSIDERED A PART OF

THE ELECTRICAL CONTRACTORS WORK. THIS WORK SHALL BE INSTALLED AS PER

NEC REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER.

21. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO MAKE ALL FEEDER RUNS

CONTINUOUS (NO CABLE BREAKS). IF SPLICING OF CABLES IN BOXES BECOMES

NECESSARY, USE BURNDY TYPE "YS-FXB" LONG BARRELED COMPRESSION SPLICE,

OR APPROVED EQUAL. WHERE INSTALLED IN THE BUILDING INTERIOR, TAPE EACH

TAP IN APPROVED MANNER. WHERE INSTALLED IN EXTERIOR LOCATIONS, UTILIZE

RAYCHEM/TYCO WCSM SHRINK TUBING, OR EQUAL.

22. WHERE CONDUIT SIZES HAVE BEEN OMITTED, THE CONTRACTOR SHALL INSTALL

THE CORRECT SIZES REQUIRED BY THE N.E.C. AS DETERMINED BY THE NUMBER OF

WIRES TO BE INSTALLED. WHERE THE NUMBER AND OR SIZES OF WIRES HAVE BEEN

OMITTED, THE CONTRACTOR SHALL INSTALL THE REQUIRED NUMBER AND OR SIZES

AS DETERMINED BY EQUIPMENT REQUIREMENTS OR FROM ADJACENT SECTIONS

AND CIRCUIT NUMBERINGS.

23. FOR INSTALLATION OF NEW DEVICES, LIGHTING FIXTURES, ETC., IN EXISTING

WALLS, ELECTRICAL CONTRACTOR SHALL PROVIDE THEIR OWN OPENINGS IN

EXISTING STRUCTURE, THE GENERAL CONTRACTOR SHALL PATCH WITH MASONRY

AND PLASTER AND RESTORE SURFACES TO MATCH EXISTING AS REQUIRED. E.C.

SHALL COORDINATE WITH G.C. AS REQUIRED.

24. THE E.C. IS TO REFER TO AND COORDINATE WITH THE HVAC/PLUMBING/FIRE

PROTECTION DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT.

E.C. SHALL ALSO INCLUDE COORDINATION WITH DEVICES FURNISHED BY M.C.,

WIRING REQUIREMENTS, INTERCONNECTIONS AND TERMINATIONS AND PROVIDE AS

REQUIRED. THE E.C. SHALL DISCONNECT ALL MECHANICAL EQUIPMENT AS

INDICATED ON THE ELECTRICAL AND MECHANICAL DEMOLITION DRAWINGS. ALL

MECHANICAL EQUIPMENT NOT INDICATED TO BE REMOVED SHALL REMAIN AS

PRESENTLY INSTALLED.

25. IN GENERAL, ALL RACEWAYS ARE TO BE CONCEALED IN WALLS AND ABOVE

CEILINGS AND UNDER FLOORS IN SO FAR AS IS POSSIBLE. RACEWAYS UTILIZED TO

SERVE EXPOSED SURFACE MOUNTED JUNCTION BOXES ARE TO BE COORDINATED

WITH THE ARCHITECT, FOR PLACEMENT AND EXACT STYLE AND FINISH TO BE

UTILIZED. GENERALLY, EXPOSED SURFACE WALL MOUNTED CONDUIT RUNS WILL

NOT BE ALLOWED IN FINISHED SPACES. THIS CONTRACTOR SHALL UTILIZE A

MINIMUM SIZE OF WIREMOLD METALLIC RACEWAY SYSTEM #V700. WHERE A

TRANSITION OCCURS OF THE CONDUIT SIZE OF 1" OR LARGER CONDUIT, THE E.C.

SHALL UTILIZE THE APPROPRIATE LARGER SIZE OF THE WIREMOLD METALLIC

RACEWAY SYSTEM OF #V2000 OR LARGER TO ACCOMMODATE THE CAPACITY OF THE

CONDUIT BEING TRANSITIONED. THE E.C. WILL BE RESPONSIBLE FOR FURNISHING

ALL APPURTENANCES REQUIRED, I.E., CLIPS, JOINERS, ELBOWS, BUSHINGS,

MOUNTING STRAPS, ETC., TO PROVIDE A COMPLETE SYSTEM, PER THE INTENT OF

THE MANUFACTURER. ALL EXPOSED RACEWAYS AND JUNCTION BOXES ARE TO BE

PAINTED, BEFORE INSTALLATION, TO MATCH THE EXISTING WALLS. COORDINATE

COLOR, FINISH AND PAINT TYPE WITH ARCHITECT.

26. ROOM NAMES & NUMBERS SHOWN ON FLOOR PLAN ARE ARCHITECTURAL NAMES

& NUMBERS. PANELBOARD DIRECTORIES SHALL BE TYPED TO INDICATE ACTUAL

ROOM NAME AND NUMBER ASSIGNED BY OWNER.

27. MECHANICAL PROTECTION OF THE EMERGENCY SYSTEM IS TO BE IMPLEMENTED

BY INSTALLATION OF BRANCH CIRCUIT CONDUCTORS INSTALLED IN NONFLEXIBLE

METAL RACEWAY SYSTEMS (I.E., CONDUIT). NONMETALLIC RACEWAYS SHALL NOT

BE USED. REFERENCE NEC 517.30.C.3.

28. WHERE DEVICES ARE INSTALLED ADJACENT TO EACH OTHER, PARTICULARLY

FROM DIFFERING SYSTEMS, THE E.C. IS TO ASSURE THAT MOUNTING BOXES ARE

ALIGNED TO CENTERLINES A.F.F. TO AFFORD SYMMETRY OF DEVICES WHEN

INSTALLATION IS COMPLETE.

FIELD IDENTIFICATION

BRKR. 25

PNL. 2CLB

1. ALL DEVICE COVERPLATES SHALL BE ENGRAVED

WITH PANELBOARD AND CIRCUIT NUMBER. LETTERS

SHALL BE 1/4" IN HEIGHT.

AutoCAD SHX Text
Title:
AutoCAD SHX Text
Revised:
AutoCAD SHX Text
Date:
AutoCAD SHX Text
No.
AutoCAD SHX Text
Project:
AutoCAD SHX Text
Courthouse Square
AutoCAD SHX Text
Ceiling Lobby Renovation
AutoCAD SHX Text
Westmoreland County
AutoCAD SHX Text
Grennsburg, PA
AutoCAD SHX Text
Electrical Notes
AutoCAD SHX Text
2019-34
AutoCAD SHX Text
E104