42
Product Data Sheet March 2019 00813-0200-2654, Rev LB RTDs (0065) and thermocouples (0185) available to meet any process requirement DIN-style for easy installation and replacement Integrated temperature assembly with Rosemount transmitters available Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Product Data SheetMarch 2019

00813-0200-2654, Rev LB

Rosemount™ DIN-Style Temperature Sensors and Thermowells (Metric)

RTDs (0065) and thermocouples (0185) available to meet any process requirement

DIN-style for easy installation and replacement

Integrated temperature assembly with Rosemount transmitters available

Page 2: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Rosemount DIN-Style Temperature Sensor and ThermowellsOptimize plant efficiency and increase measurement reliability with industry-proven design and specifications Available in a wide variety of sensing technologies – RTD and

thermocouples.

All sensor styles and lengths are available in 6 mm diameter.

State of the art manufacturing procedures provide robust element packaging and increasing reliability.

Industry-leading calibration capabilities allow for Callendar-Van Dusen values to give increased accuracy when paired with Rosemount transmitters.

Optional Class A accuracy for critical temperature measurement points.

Streamline operations and maintenance with sensor and thermowell design DIN-style sensor uses connection heads that allow quick

mounting and replacement while maintaining environmental integrity.

Terminal block, flying leads, and spring loaded threaded adapter styles offer remote or integral transmitter mounting configuration.

Explore the benefits of Complete Point Solutions™ from Emerson An “Assemble Sensor to Specific Transmitter” option enables

Emerson to provide a complete point temperature solution, delivering an installation-ready transmitter and sensor assembly.

Emerson has a complete portfolio of single point and high density temperature measurement solutions, allowing you to effectively measure and control your processes with the reliability you trust from Rosemount products.

Experience global consistency and local support from numerous worldwide Rosemount Temperature manufacturing sites World-class manufacturing provides globally consistent

products from every factory and the capacity to fulfill theneeds of any project, large or small.

Experienced instrumentation consultants help select the right product for any temperature application and advise on best installation practices.

An extensive global network of Emerson service and support personnel can be on-site when and where they are needed.

Content

Rosemount DIN-Style Sensor and Thermowell . . . . . . . . 3

Rosemount Series 96 Barstock Thermowell . . . . . . . . . 18

Sensor reference information . . . . . . . . . . . . . . . . . . . . . . 22

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Sensor-to-Transmitter Matching . . . . . . . . . . . . . . . . . . .30

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

Wake frequency calculation . . . . . . . . . . . . . . . . . . . . . . .41

2 Emerson.com/Rosemount

Page 3: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Rosemount DIN-Style Sensor and ThermowellThe Rosemount DIN-Style Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments.

Features include:

Temperature range of –196 to 450 °C for RTD, –40 to 1000 °C for thermocouple

Industry-standard sensor types, including RTD and thermocouple varieties

DIN-style design for easy mounting and replacement

Variety of enclosure and connection head options

Global hazardous-location approvals available

Calibration services available to give you insight to sensor performance

MID calibration options for custody transfer

Assemble to transmitter option

Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 25 for more information on material selection.

Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell

The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

Model Product description

0065 Pt 100 RTD (IEC 751) without thermowell

0185 Thermocouple (IEC 584 Class 1) without thermowell

Connection head IP rating(1) Conduit/cable entry

C Rosemount aluminum 66/68 M20 � 1.5 ★

D Rosemount aluminum 66/68 1/2-in. NPT ★

1 Rosemount aluminum with LCD display meter cover 66/68 M20 �1.5 ★

2 Rosemount aluminum with LCD display meter cover 66/68 1/2-in. NPT ★

N No connection head N/A N/A ★

G Rosemount stainless steel 66/68 M20 � 1.5

H Rosemount stainless steel 66/68 1/2-in. NPT

J GR–A/BL (BUZ) aluminum w/cable gland 65 M20 � 1.5

L TZ–A/BL (BUZH) aluminum w/cable gland 65 M20 � 1.5

7 Aluminum dual entry head 66 2 � 3/4-in. NPT

8 Aluminum dual entry head 66 2 � M20 � 1.5

9 Aluminum dual entry head 66 2 � 1/2-in. NPT

K Stainless steel dual entry head 66 2 � 3/4-in. NPT

R Stainless steel dual entry head 66 2 � M20 � 1.5

Connection head IP rating(1) Conduit/cable entry

W Stainless steel dual entry head 66 2 � 1/2-in. NPT

A TZ-A/BL (BUZH) aluminum coated 65 M20 � 1.5

P SD-BK N/A M20 � 1.5

3Emerson.com/Rosemount

Page 4: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Sensor lead wire termination

0 Flying leads (no springs on DIN plate) ★

2 Terminal block (DIN 43762) ★

3 Spring loaded adapter (1/2-in. NPT) ★

Sensor type Temperature range

65 O

nly

1 RTD, single element, 4-wire –50 to 450 °C (–58 to 842 °F) ★

2 RTD, dual element, 3-wire –50 to 450 °C (–58 to 842 °F) ★

3 RTD, single element, 4-wire –196 to 300 °C (–321 to 572 °F) ★

4 RTD, dual element, 3-wire –196 to 300 °C (–321 to 572 °F) ★

185

On

ly

03J1 Thermocouple, Type J, single element, ungrounded –40 to 750 °C (–40 to 1382 °F) ★

03K1 Thermocouple, Type K, single element, ungrounded –40 to 1000 °C (–40 to 1832 °F) ★

05J1 Thermocouple, Type J, dual element, isolated, ungrounded –40 to 750 °C (–40 to 1382 °F) ★

05K1 Thermocouple, Type K, dual element, isolated, ungrounded –40 to 1000 °C (–40 to 1832 °F) ★

65 O

nly 7 RTD, Single element, 3-wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

9 RTD, Single element, 4-wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

0 RTD, Dual Element, 3-wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

185

On

ly 03N1 Thermocouple, Type N, single element, ungrounded –40 to 1000 °C (–40 to 1832 °F)

05N1 Thermocouple, Type N, dual element, isolated, ungrounded –40 to 1000 °C (–40 to 1832 °F)

ExtensionHead

connectionInstrument connection

Material

D DIN Standard 12 � 1.5 M24 � 1.5 1/2-in. NPT 300 series stainless steel ★

T DIN Standard 12 � 1.5 M24 � 1.5 M18 � 1.5 300 series stainless steel ★

F Nipple union nipple 1/2-in. NPT 1/2-in. NPT 300 series stainless steel ★

J Nipple union (M/F) N/A 1/2-in. NPT 300 series stainless steel ★

N No extension (only available with connection head code N) ★

W No extension head connection M24 � 1.5 ★

L No extension head connection 1/2-in. NPT ★

Extension length (N) in millimeters

0000 No extension (use with extension code N, W, or L) ★

0035 35 mm ★

0080 80 mm (standard for extension type code J) ★

0110 110 mm (standard for extension type codes F and J) ★

0135 135 mm (standard for DIN extension used with Rosemount connection head material codes C, D, G, H, 1, and 2) ★

0150 150 mm (standard for DIN extension used with form B connection head material codes J and L) ★

XXXX Non-standard extension length (available from 35 to 500 mm in 5 mm increments)

Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell

The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

4 Emerson.com/Rosemount

Page 5: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Thermowell material

N No thermowell ★

Sensor length (L) in millimeters

0145 145 mm ★

0205 205 mm ★

0275 275 mm ★

0315 315 mm ★

0375 375 mm ★

0405 405 mm ★

0435 435 mm ★

0555 555 mm ★

XXXX Non-standard sensor length (available from 100 to 9999 mm in 5-mm increments)

Options (include with selected model number)

Sensor options (available with 65 only) Temperature range

A1 Single element class A sensor –50 to 300 °C (–58 to 572 °F) (0 –350 °C for sensor types 7, 9,0 ) ★

A2 Dual element class A sensor –50 to 300 °C (–58 to 572 °F) (0–350 °C for sensor types 7, 9, 0) ★

Product certifications(2)

I1 ATEX Intrinsic Safety Approval ★

N1 ATEX Type n Approval ★

E1 ATEX Flameproof Approval ★

ND ATEX Dust Approval ★

K1 ATEX Flameproof, Intrinsic Safety, Type n, and Dust Approval ★

E7 IECEx Flameproof Approval ★

E5 US Explosionproof Approval ★

E4 TIIS Flameproof Approval (consult factory for availability) ★

E6 Canada Explosionproof Approval ★

E2 Brazil Flameproof Approval ★

KD US Explosionproof, Canada Explosionproof, and ATEX Flameproof Approval ★

KM Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety Approval ★

IM Technical Regulations Customs Union (EAC) Intrinsic Safety Approval ★

EM Technical Regulations Customs Union (EAC) Flameproof Approval ★

Ground screw

G1 External ground screw (only available with Rosemount connection head codes C, D, G, H, 1, and 2) ★

Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell

The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

5Emerson.com/Rosemount

Page 6: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Cable glands

G2 Cable gland, EEx d, brass, diam 7.5–11.9 mm

G4 Cable gland, M20 � 1.5 EMV, brass nickel coated, diam 9–13 mm

G5 Cable gland, M20 � 1.5 EMV, brass nickel coated, diam 5–13 mm

G7 Cable gland, M20 � 1.5, EEx e, blue, polyamide, diam 5–9 mm

Cover chain option

G3 Cover chain (only available with Rosemount connection head codes C, D, G, and H) ★

Extension ring

G6 Aluminum extension ring for dual transmitter mounting (use with Rosemount connection head codes C and D) ★

Termination

TB Terminal block for use with sensor termination code 3 ★

Assemble to option

XA(3) Assemble sensor to specific temperature transmitter (PTFE paste) ★

Sensor calibration with works certificate (available with 65 only)

V10 Sensor calibration from –50 to 450 °C (–58 to 842 °F) with A, B, C, and Callendar-Van Dusen constants ★

V11 Sensor calibration from 0 to 100 °C (32 to 212 °F) with A, B, C, and Callendar-Van Dusen constants ★

X8 Sensor calibration over specified temperature range with A, B, C, and Callendar-Van Dusen constants ★

VS system calibration (available with 65 only)

MD1 MID custody transfer, –196 to 0 °C (–321 to 32 °F) ★

MD2 MID custody transfer, –50 to 100 °C (–58 to 212 °F) ★

MD3 MID custody transfer, 50 to 200 °C (122 to 392 °F) ★

GOST calibration certificate

QG Russian GOST Verification Certificate ★

Temperature range option

LT Special materials to meet extended temperature range of –51 °C (–60 °F) ★

Typical model number: 0065 C 2 3 D 0150 N 0315 A1

1. To maintain IP rating, use a suitable cable gland on the conduit connection thread. All threads must be sealed with a suitable sealing tape.

2. Refer to Table 7 on page 29 for limitation on options available with approvals.

3. If ordering Assemble To Option XA with a transmitter, specify the same option on the transmitter model number.

Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell

The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

6 Emerson.com/Rosemount

Page 7: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 25 for more information on material selection.

Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time

Model Product description

0065 Pt 100 RTD (IEC 751) with tubular thermowell

0185 Thermocouples (IEC 584 Class 1) with tubular thermowell

Connection head IP rating(1) Conduit/cable entry

C Rosemount aluminum 66/68 M20 � 1.5 ★

D Rosemount aluminum 66/68 1/2-in. NPT ★

1 Rosemount aluminum with LCD display meter cover 66/68 M20 � 1.5 ★

2 Rosemount aluminum with LCD display meter cover 66/68 1/2-in. NPT ★

N No connection head N/A N/A ★

G Rosemount stainless steel 66/68 M20 � 1.5

H Rosemount stainless steel 66/68 1/2-in. NPT

J GR–A/BL (BUZ) aluminum w/ cable gland 65 M20 � 1.5

L TZ–A/BL (BUZH) aluminum w/ cable gland 65 M20 � 1.5

7 Aluminum dual entry head 66 2 � 3/4-in. NPT

8 Aluminum dual entry head 66 2 � M20 � 1.5

9 Aluminum dual entry head 66 2 � 1/2-in. NPT

K Stainless steel dual entry head 66 2 � 3/4-in. NPT

R Stainless steel dual entry head 66 2 � M20 � 1.5

W Stainless steel dual entry head 66 2 � 1/2-in. NPT

A TZ-A/BL (BUZH) aluminum coated 65 M20 � 1.5

P SD-BK N/A M20 � 1.5

Sensor lead wire termination

0 Flying leads (no springs on DIN plate) ★

2 Terminal block (DIN 43762) ★

Sensor type Temperature range

65 o

nly

1 RTD, single element, 4-wire – 50 to 450 °C (–58 to 842 °F) ★

2 RTD, dual element, 3-wire –50 to 450 °C (–58 to 842 °F) ★

3 RTD, single element, 4-wire –196 to 300 °C (–321 to 572 °F) ★

4 RTD, dual element, 3-wire –196 to 300 °C (–321 to 572 °F) ★

185

on

ly

03J1 Thermocouple, Type J, single element, ungrounded –40 to 750 °C (–40 to 1382 °F) ★

03K1 Thermocouple, Type K, single element, ungrounded –40 to 1000 °C (–40 to 1832 °F) ★

05J1 Thermocouple, Type J, dual element, isolated, ungrounded –40 to 750 °C (–40 to 1382 °F) ★

05K1 Thermocouple, Type K, dual element, isolated, ungrounded –40 to 1000 °C (–40 to 1832 °F) ★

7Emerson.com/Rosemount

Page 8: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

8 Emerson.com/Rosemount

Sensor type Temperature range

65 o

nly 7 RTD, single element, 3-wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

9 RTD, single element, 4-wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

0 RTD, dual element, 3-wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

185

on

ly 03N1 Thermocouple, Type N, single element, ungrounded –40 to 1000 °C (–40 to 1832 °F)

05N1 Thermocouple, Type N, dual element, isolated, ungrounded –40 to 1000 °C (–40 to 1832 °F)

Extension

Y Tubular, no extension (only available with form GN) ★

Z Tubular, with extension (only available with form GB, NAMUR) ★

Extension length (N) in millimeters

0000 No extension (use with extension code Y) ★

0050 50 mm ★

0065 65 mm ★

0105 105 mm ★

0115 115 mm ★

0130 130 mm ★

0200 200 mm ★

0250 250 mm ★

XXXX Non-standard extension length (available from 50 to 500 mm in 5 mm increments)

Thermowell material

D 1.4404 (316L SST) ★

Y 1.4571 (316Ti SST) ★

Immersion length (U)

0050 50 mm ★

0075 75 mm ★

0100 100 mm ★

0115 115 mm ★

0130 130 mm ★

0150 150 mm ★

0160 160 mm ★

0200 200 mm ★

0220 220 mm ★

0225 225 mm ★

0250 250 mm ★

0280 280 mm ★

0300 300 mm ★

Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time

Page 9: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Immersion length (U)

0345 345 mm ★

0400 400 mm ★

XXXX Non-standard immersion length (available from 50 to 2500 mm in 5 mm increments)

Thermowell mounting style Process connections Stem style

G02(2) Threaded, tapered R 1/2-in. (1/2-in. BSPT) Stepped, NAMUR ★

G04(2) Threaded, tapered R 3/4-in. (3/4-in. BSPT) Stepped, NAMUR ★

G06(2) Threaded, tapered R 1-in. (1-in. BSPT) Stepped, NAMUR ★

G13(2) Threaded, parallel M27 � 2 Stepped, NAMUR ★

G20(2) Threaded, parallel G 1/2-in. (1/2-in. BSPF) Stepped, NAMUR ★

G22(2) Threaded, parallel G 3/4-in. (3/4-in. BSPF) Stepped, NAMUR ★

G24(2) Threaded, parallel G1 -in. (1-in. BSPF) Stepped, NAMUR ★

G91(2) Threaded, parallel M20 � 1.5 Stepped, NAMUR ★

G31(2) Threaded, parallel M33 � 2 Stepped, NAMUR ★

G38(2) Threaded, tapered 1/2-in. NPT Stepped, NAMUR ★

G40(2) Threaded, tapered 3/4-in. NPT Stepped, NAMUR ★

G42(2) Threaded, tapered 1-in. NPT Stepped, NAMUR ★

G52(3) Threaded, parallel G 1/2-in. (1/2-in. BSPF) Straight, GN, D. 9 � 1 mm ★

G92(3) Threaded, parallel M20 � 1.5 Straight, GN, D. 9 � 1 mm ★

G63(3) Threaded, parallel G 1/2-in. (1/2-in. BSPF) Straight, GN, D. 11� 2 mm ★

G94(3) Threaded, parallel M20 � 1.5 Straight, GN, D. 11 � 2 mm ★

G72(3) Threaded, parallel G 1/2-in. (1/2-in. BSPF) Straight, GN, D. 9 � 1 mm ★

G95(3) Threaded, parallel M20 � 1.5 Straight, GN, D. 9 � 1 mm ★

L02(2) Flanged, RF 1-in. 150 lb Stepped, NAMUR ★

L08(2) Flanged, RF 11/2-in. 150 lb Stepped, NAMUR ★

L14(2) Flanged, RF 2-in. 150 lb Stepped, NAMUR ★

L20(2) Flanged, RF 1-in. 300 lb Stepped, NAMUR ★

L26(2) Flanged, RF 11/2-in. 300 lb Stepped, NAMUR ★

L32(2) Flanged, RF 2-in. 300 lb Stepped, NAMUR ★

H02(2) Flange, Form B1 according to EN 1092-1 DN 25 PN 16 Stepped, NAMUR ★

H08(2) Flange, Form B1 according to EN 1092-1 DN 25 PN 25/40 Stepped, NAMUR ★

H14(2) Flange, Form B1 according to EN 1092-1 DN 40 PN 16 Stepped, NAMUR ★

H20(2) Flange, Form B1 according to EN 1092-1 DN 40 PN 25/40 Stepped, NAMUR ★

H26(2) Flange, Form B1 according to EN 1092-1 DN 50 PN 40 Stepped, NAMUR ★

Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time

9Emerson.com/Rosemount

Page 10: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Options (include with selected model number)

Sensor options (available with 65 only) Temperature range

A1 Single element class A sensor –50 to 300 °C (–58 to 572 °F) (0 to 350 °C for sensor types 7, 9, 0) ★

A2 Dual element class A sensor –50 to 300 °C (–58 to 572 °F) (0 to 350 °C for sensor types 7, 9, 0) ★

Product certifications(4)

I1 ATEX Intrinsic Safety Approval ★

N1 ATEX Type n Approval ★

E1 ATEX Flameproof Approval ★

ND ATEX Dust Approval ★

K1 ATEX Flameproof, Intrinsic Safety, Type n, and Dust Approval ★

E7 IECEx Flameproof Approval ★

E5 US Explosionproof Approval ★

E4 TIIS Flameproof Approval (consult factory for availability) ★

E6 Canada Explosionproof Approval ★

E2 Brazil Flameproof Approval ★

KD US Explosionproof, Canada Explosionproof, and ATEX Explosionproof Approval ★

KM Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety Approval ★

IM Technical Regulations Customs Union (EAC) Intrinsic Safety Approval ★

EM Technical Regulations Customs Union (EAC) Flameproof Approval ★

Ground screw

G1 External ground screw (only available with Rosemount connection head codes C, D, G, H, 1, and 2) ★

Cable glands

G2 Cable gland, EEx d, brass, diam 7.5–11.9 mm

G4 Cable gland, M20 � 1.5 EMV, brass nickel coated, diam 9–13 mm

G5 Cable gland, M20 � 1.5 EMV, brass nickel coated, diam 5–13 mm

G7 Cable gland, M20 � 1.5, EEx e, blue, polyamide, diam 5–9 mm

Cover chain option

G3 Cover chain (only available with Rosemount connection head codes C, D, G, and H) ★

Extension ring

G6 Aluminum extension ring for dual transmitter mounting (use with Rosemount connection head codes C and D) ★

Material certification

Q8 Thermowell material certification, DIN EN 10204 3.1 ★

External pressure test

R01 Thermowell external pressure testing ★

Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time

10 Emerson.com/Rosemount

Page 11: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Dye test

R03 Thermowell dye penetration testing ★

Special cleaning

R04 Thermowell special cleaning ★

Assemble to options(5)

XA Assemble sensor to specific temperature transmitter (PTFE paste) ★

Sensor calibration with works certificate (available with 65 only)

V10 Sensor calibration from –50 to 450 °C (–58 to 842 °F) with A, B, C, and Callendar-Van Dusen constants ★

V11 Sensor calibration from 0 to 100 °C (32 to 212 °F) with A, B, C, and Callendar-Van Dusen constants ★

X8 Sensor calibration over specified temperature range with A, B, C, and Callendar-Van Dusen constants ★

Temperature range option

LT Special material to meet extended temperature range of –51 °C (–60 °F) ★

Typical model number: 0065 G 2 2 D 0135 D 0225 F70 Q8 R01 R07

1. To maintain IP rating, use a suitable cable gland on the conduit connection thread. All threads must be sealed with a suitable sealing tape.

2. The NAMUR stepped profile is available in both thermowell material options, however to maintain NAMUR compliance material code Y is required. 115 mm is the minimum immersion length stepped thermowells are available and is the minimum requirement to maintain NAMUR compliance however for lengths shorter than 115 mm a straight thermowell with a 8 mm OD will be provided.

3. Not available with thermowell Material code D.

4. Refer to Table 7 on page 29 for limitation on options available with approvals.

5. If ordering Assemble To option XA with a transmitter, specify the same option on the transmitter model number.

Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time

11Emerson.com/Rosemount

Page 12: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 25 for more information on material selection.

Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

Model Product description

0065 Pt 100 RTD (IEC 751) with barstock thermowell

0185 Thermocouples (IEC 584 Class 1) with barstock thermowell

Connection head IP rating(1) Conduit/cable entry

C Rosemount aluminum 66/68 M20 � 1.5 ★

D Rosemount aluminum 66/68 1/2-in. NPT ★

1 Rosemount aluminum with LCD display meter cover 66/68 M20 � 1.5 ★

2 Rosemount aluminum with LCD display meter cover 66/68 1/2-in. NPT ★

N No connection head N/A N/A ★

G Rosemount stainless steel 66/68 M20 � 1.5

H Rosemount stainless steel 66/68 1/2-in. NPT

J GR–A/BL (BUZ) aluminum w/ cable gland 65 M20 � 1.5

L TZ–A/BL (BUZH) aluminum w/ cable gland 65 M20 � 1.5

7 Aluminum dual entry head 66 2 � 3/4-in. NPT

8 Aluminum dual entry head 66 2 � M20 � 1.5

9 Aluminum dual entry head 66 2 � 1/2-in. NPT

K Stainless steel dual entry head 66 2 � 3/4-in. NPT

R Stainless steel dual entry head 66 2 � M20 � 1.5

W Stainless steel dual entry head 66 2 � 1/2-in. NPT

A TZ-A/BL (BUZH) aluminum coated 65 M20 � 1.5

P SD-BK N/A M20 � 1.5

Sensor lead wire termination

0 Flying leads (no springs on DIN plate) ★

2 Terminal block (DIN 43762) ★

3 Spring loaded adapter (1/2-in. NPT) ★

Sensor type Temperature range

65 O

nly

1 RTD, single element, 4-wire –50 to 450 °C (–58 to 842 °F) ★

2 RTD, dual element, 3-wire –50 to 450 °C (–58 to 842 °F) ★

3 RTD, single element, 4-wire –196 to 300 °C (–321 to 572 °F) ★

4 RTD, dual element, 3-wire –196 to 300 °C (–321 to 572 °F) ★

185

On

ly

03J1 Thermocouple, Type J, single element, ungrounded –40 to 750 °C (–40 to 1382 °F) ★

03K1 Thermocouple, Type K, single element, ungrounded –40 to 1000 °C (–40 to 1832 °F) ★

05J1 Thermocouple, Type J, dual element, isolated, ungrounded –40 to 750 °C (–40 to 1382 °F) ★

05K1 Thermocouple, Type K, dual element, isolated, ungrounded –40 to 1000 °C (–40 to 1832 °F) ★

12 Emerson.com/Rosemount

Page 13: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Sensor type Temperature range

65 o

nly 7 RTD, single element, 3 wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

9 RTD, single element, 4 wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

0 RTD, dual element, 3 wire vibration resistance –60 to 600 °C (–76 to 1112 °F)

185

on

ly 03N1 Thermocouple, Type N, single element, ungrounded –40 to 1000 °C (–40 to 1832 °F)

05N1 Thermocouple, Type N, dual element, isolated, ungrounded –40 to 1000 °C (–40 to 1832 °F)

Extension Head

connectionInstrument connection

Materials

D DIN standard 12 � 1.5 M24 � 1.5 1/2-in. NPT 300 SST ★

T DIN standard 12 � 1.5 M24 � 1.5 M18 � 1.5 300 SST ★

F Nipple union nipple 1/2-in. NPT 1/2-in. NPT 300 SST ★

J Nipple union (M/F) None 1/2-in. NPT 300 SST ★

N No extension (only available with connection head code N) ★

Extension length (N) in millimeters

0000 No extension (use with extension code N) ★

0035 35 mm ★

0080 80 mm (standard for extension type code J) ★

0110 110 mm (standard for extension type codes F and J) ★

0135 135 mm (standard for DIN extension used with Rosemount connection head material codes C, D, G, H, 1, and 2) ★

0150 150 mm (standard for DIN extension used with Form B connection head material codes J and L) ★

XXXX Non-standard extension length (available from 35 to 500 mm in 5 mm increments)

Thermowell material

D 1.4404 (316L SST) ★

Y 1.4571 (316Ti SST) ★

A 1.4401 (316 SST)

J 2.4819 (Alloy C-276)

K 1.5415 (A 204 Size A)

P 1.7380 (A 182-Grade F22)

Z 1.7335 (A 182-Grade F11)

Immersion length (U)

0065 65 mm ★

0075 75 mm ★

0115 115 mm ★

0125 125 mm ★

0150 150 mm ★

Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

13Emerson.com/Rosemount

Page 14: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

0225 225 mm ★

0300 300 mm ★

0450 450 mm ★

XXXX Non-standard immersion length (available from 50 to 1000 mm in 5 mm increments)

Code Thermowell mounting style Process connections Stem style

T08 Threaded R 1/2-in. (1/2-in. BSPT) Tapered ★

T10 Threaded R 3/4-in. (3/4-in.BSPT) Tapered ★

T12 Threaded R 1-in. (1-in. BSPT) Tapered ★

T26(2) Threaded G 1/2-in. (1/2-in. BSPF) Tapered ★

T28(2) Threaded G 3/4-in. (3/4-in.BSPF) Tapered ★

T30(2) Threaded G 1-in. (1-in. BSPF) Tapered ★

T44 Threaded 1/2-in. NPT Tapered ★

T46 Threaded 3/4-in. NPT Tapered ★

T48 Threaded 1-in. NPT Tapered ★

T93(2) Threaded M27 � 2 Tapered ★

T95(2) Threaded M33 � 2 Tapered ★

T98(2) Threaded M20 � 1.5 Tapered ★

F04 Flanged, RF 1-in. 150 lb Tapered ★

F10 Flanged, RF 11/2-in. 150 lb Tapered ★

F16 Flanged, RF 2-in. 150 lb Tapered ★

F22 Flanged, RF 1-in. 300 lb Tapered ★

F28 Flanged, RF 11/2-in. 300 lb Tapered ★

F34 Flanged, RF 2-in. 300 lb Tapered ★

F40 Flanged, RF 1-in. 600 lb Tapered ★

F46 Flanged, RF 11/2-in. 600 lb Tapered ★

F52 Flanged, RF 2-in. 600 lb Tapered ★

F58(3) Flanged, RF 1-in. 900/1500 lb Tapered ★

F64(3) Flanged, RF 11/2-in. 900/1500 lb Tapered ★

F70(3)(4) Flanged, RF 2-in. 900/1500 lb Tapered ★

F82(3)(4) Flanged, RF 11/2-in. 2500 lb Tapered ★

F88(3)(4) Flanged, RF 2-in. 2500 lb Tapered ★

D04 Flange, Form B1 according to EN 1092-1 DN 25 PN 16 Tapered ★

D10 Flange, Form B1 according to EN 1092-1 DN 25 PN 25/40 Tapered ★

D16 Flange, Form B1 according to EN 1092-1 DN 40 PN 16 Tapered ★

D22 Flange, Form B1 according to EN 1092-1 DN 40 PN 25/40 Tapered ★

Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

14 Emerson.com/Rosemount

Page 15: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Code Thermowell mounting style Process connections Stem style

D28 Flange, Form B1 according to EN 1092-1 DN 50 PN 40 Tapered ★

W10 Welded 3/4-in. pipe Tapered ★

W12 Welded 1-in. pipe Tapered ★

W14 Welded 11/4-in. pipe Tapered ★

W16 Welded 11/2-in. pipe Tapered ★

E01(5)(6) D1 welded 24h7 Tapered ★

E02(5)(6) D2 welded 24h7 Tapered ★

E04(5)(7) D4 welded 24h7 Tapered ★

E05(5)(7) D5 welded 24h7 Tapered ★

Options (include with selected model number)

Sensor options (available with 65 only) Temperature range

A1 Single element Class A sensor –50 to 300 °C (–58 to 572 °F) (0 to 350 °C for sensor types 7, 9, 0) ★

A2 Dual element Class A sensor –50 to 300 °C (–58 to 572 °F) (0 to 350 °C for sensor types 7, 9, 0) ★

Product certifications(8)

I1 ATEX Intrinsic Safety Approval ★

N1 ATEX Type n Approval ★

E1 ATEX Flameproof Approval ★

ND ATEX Dust Approval ★

K1 ATEX Flameproof, Intrinsic Safety, Type n, and Dust Approval ★

E7 IECEx Flameproof Approval ★

E5 US Explosionproof Approval ★

E4 TIIS Flameproof Approval (consult factory for availability) ★

E6 Canada Explosionproof Approval ★

E2 Brazil Flameproof Approval ★

KD USA Explosionproof, Canada Explosionproof, and ATEX Flameproof Approval ★

KM Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety Approval ★

IM Technical Regulations Customs Union (EAC) Intrinsic Safety Approval ★

EM Technical Regulations Customs Union (EAC) Flameproof Approval ★

Ground screw

G1 External ground screw (only available with Rosemount connection head codes C, D, G, H, 1, and 2) ★

Cable glands

G2 Cable gland, EEx d, brass, diameter 7.5–11.9 mm

G4 Cable gland, M20 � 1.5 EMV, brass nickel coated, diameter 9–13 mm

Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

15Emerson.com/Rosemount

Page 16: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Cable glands

G5 Cable gland, M20 � 1.5 EMV, brass nickel coated, diameter 5–13 mm

G7 Cable gland, M20 � 1.5, EEx e, blue, polyamide, diameter 5–9 mm

Cover chain option

G3 Cover chain (only available with Rosemount connection head codes C, D, G, and H) ★

Extension ring

G6 Aluminum extension ring for dual transmitter mounting (use with Rosemount connection head codes C and D) ★

Termination

TB Terminal block for use with sensor termination code 3 ★

Material certification

Q8 Thermowell material certification, DIN EN 10204 3.1 ★

External pressure test

R01 Thermowell external pressure testing ★

Internal pressure test

R22 Thermowell internal pressure testing ★

Dye test

R03 Thermowell dye penetration testing ★

Special cleaning

R04 Thermowell special cleaning ★

NACE® approval(9)

R05 Thermowell NACE approval ★

Plug/chain

R06 Stainless steel plug and chain ★

Weld options

R07 Full penetration weld (for flanged thermowells only) ★

Wake frequency

R21 Wake frequency (thermowell strength calculation) ★

Assemble to options(10)

XA Assemble sensor to specific temperature transmitter (PTFE paste) ★

Sensor calibration with works certificate (available with 65 only)

V10 Sensor calibration from –50 to 450 °C (–58 to 842 °F) with A, B, C, and Callendar-Van Dusen constants ★

Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

16 Emerson.com/Rosemount

Page 17: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Sensor calibration with works certificate (available with 65 only)

V11 Sensor calibration from 0 to 100 °C (32 to 212 °F) with A, B, C, and Callendar-Van Dusen constants ★

X8 Sensor calibration over specified temperature range with A, B, C, and Callendar-Van Dusen constants ★

VS system calibration

MD1 MID custody transfer, –196 to 0 °C (–321 to 32 °F) ★

MD2 MID custody transfer, –50 to 100 °C (–58 to 212 °F) ★

MD3 MID custody transfer, 50 to 200 °C (122 to 392 °F) ★

Temperature range option

LT Special material to meet extended temperature range of –51 °C (–60 °F) ★

Typical model number: 0065 G 2 2 D 0135 D 0225 F70 Q8 R01 R07

1. To maintain IP rating, use a suitable cable gland on the conduit connection thread. All threads must be sealed with a suitable sealing tape.

2. This mounting style is only available with the lagging length code T040.

3. Full penetration weld option R07 is required with this mounting style.

4. This mounting style has a minimum lagging length of 80 mm.

5. Only available with extension style T.

6. This mounting style is only available with the lagging length code T075.

7. This mounting style is only available with the lagging length code T135.

8. Refer to Table 7 on page 29 for limitation on options available with approvals.

9. Only available with thermowell material codes D, J, and A.

10. If ordering Assemble To Option XA with a transmitter, specify the same option on the transmitter model number.

Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

17Emerson.com/Rosemount

Page 18: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Rosemount Series 96 Barstock ThermowellThe Rosemount Series 96 Barstock Thermowell has designs that provide flexible and reliable temperature measurements in process environments.

Features include:

Threaded, flanged, and weld-in styles

Wake frequency calculations conforming to ASME PTC 19.3

NACE approval available

Variety of testing and certification options available

Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 25 for more information on material selection.

Table 4. Series 96 Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

Model Product description

0096 Barstock thermowell

Thermowell material(1)

D 1.4404 (316L SST) ★

Y 1.4571 (316Ti SST) ★

A 1.4401 (316 SST)

J 2.4819 (Alloy C-276)

K 1.5415 (204 Size A)

P 1.7380 (182 Grade-F22)

Z 1.7335 (182 Grade-F11)

Immersion length (L) in millimeters

0065 65 mm (standard length for weld-in thermowells, E01 and E04) ★

0075 75 mm ★

0115 115 mm ★

0125 125 mm (standard length for weld-in thermowells, E02 and E05) ★

0150 150 mm ★

0225 225 mm ★

0300 300 mm ★

0450 450 mm ★

XXXX Non-standard immersion length (available from 25 to 1000 mm in 5-mm increments)

Thermowell mounting style Process connections Stem style

T08 Thread R 1/2-in. (1/2-in. BSPT) Tapered ★

T10 Thread R 3/4-in. (3/4-in.BSPT) Tapered ★

T12 Thread R 1-in. (1-in. BSPT) Tapered ★

T26(2) Thread G 1/2-in. (1/2-in. BSPF) Tapered ★

18 Emerson.com/Rosemount

Page 19: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

T28(2) Thread G 3/4-in. (3/4-in.BSPF) Tapered ★

T30(2) Thread G 1-in. (1-in. BSPF) Tapered ★

T44 Thread 1/2-in. NPT Tapered ★

T46 Thread 3/4-in. NPT Tapered ★

T48 Thread 1-in. NPT Tapered ★

T93(2) Thread M27 � 2 Tapered ★

T95(2) Thread M33 � 2 Tapered ★

T98(2) Thread M20 � 1.5 Tapered ★

F04 Flange, RF 1-in. 150 lb Tapered ★

F10 Flange, RF 11/2-in. 150 lb Tapered ★

F16 Flange, RF 2-in. 150 lb Tapered ★

F22 Flange, RF 1-in. 300 lb Tapered ★

F28 Flange, RF 11/2-in. 300 lb Tapered ★

F34 Flange, RF 2-in. 300 lb Tapered ★

F40 Flange, RF 1-in. 600 lb Tapered ★

F46 Flange, RF 11/2-in. 600 lb Tapered ★

F52 Flange, RF 2-in. 600 lb Tapered ★

F58(3) Flanged, RF 1-in. 900/1500 lb Tapered ★

F64(3) Flanged, RF 11/2-in. 900/1500 lb Tapered ★

F70(3)(4) Flanged, RF 2-in. 900/1500 lb Tapered ★

F82(3)(4) Flanged, RF 11/2-in 2500 lb Tapered ★

F88(3)(4) Flanged, RF 2-in. 2500 lb Tapered ★

D04 Flange, Form B1 according to EN 1092-1 DN 25 PN 16 Tapered ★

D10 Flange, Form B1 according to EN 1092-1 DN 25 PN 25/40 Tapered ★

D16 Flange, Form B1 according to EN 1092-1 DN 40 PN 16 Tapered ★

D22 Flange, Form B1 according to EN 1092-1 DN 40 PN 25/40 Tapered ★

D28 Flange, Form B1 according to EN 1092-1 DN 50 PN 40 Tapered ★

W10 Welded 3/4-in. pipe Tapered ★

W12 Welded 1-in. pipe Tapered ★

W14 Welded 11/4-in. pipe Tapered ★

W16 Welded 11/2-in. pipe Tapered ★

Thermowell mounting style Process connections Stem style

E01(5) D1 welded, DIN 24h7 Tapered ★

E02(5) D2 welded, DIN 24h7 Tapered ★

E04(6) D4 welded, DIN 24h7 Tapered ★

E05(6) D5 welded, DIN 24h7 Tapered ★

Table 4. Series 96 Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

19Emerson.com/Rosemount

Page 20: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Lagging length

T040 40 mm ★

T060 60 mm ★

T075 75 mm ★

T080 80 mm ★

T135 135 mm ★

TXXX Non standard lagging length

Instrument connection thread type

A M24 � 1.5 ★

D 1/2-in. NPT ★

T M18 � 1.5 (valid for weld-in thermowells codes E01, E02, E04, and E05) ★

Options (include with selected model number)

Material certification

Q8 Thermowell material certification ★

External pressure test

R01 Thermowell external pressure testing (flanged thermowells only) ★

Internal pressure test

R22 Thermowell internal pressure test ★

Dye test

R03 Thermowell dye penetration testing ★

Special cleaning

R04 Thermowell special cleaning ★

NACE approval(7)

R05 Thermowell NACE approval ★

Plug/chain

R06 Stainless steel plug and chain ★

Weld options

R07 Full penetration weld - for flanged thermowells only ★

Flange type

R16 Ring joint flange face ★

Table 4. Series 96 Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

20 Emerson.com/Rosemount

Page 21: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Wake frequency calculation

R21 Wake frequency (thermowell strength calculation) ★

Typical model number: 0096 D 0300 F04 T060 D Q8 R01

1. Additional materials are available upon request.

2. This mounting style is only available with the lagging length code T040.

3. Full penetration weld option R07 is required with this mounting style.

4. This mounting style has a minimum lagging length of 80 mm.

5. This mounting style is only available with the lagging length code T075.

6. This mounting style is only available with the lagging length code T135.

7. Only available with thermowell material codes D, J, and A.

Table 4. Series 96 Barstock Thermowell

★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.The Expanded offering is subject to additional delivery lead time.

21Emerson.com/Rosemount

Page 22: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Sensor reference information

Overview

Rosemount integral mount temperature sensors, accessory hardware, and assemblies constitute a complete line of industrial temperature-sensing instruments. A variety of RTD and thermocouple sensors are available alone, or as complete assemblies including connection heads, thermowells, and extension fittings. Emerson offers complete temperature measurement assemblies including Rosemount Smart and Programmable Temperature Transmitters. Ask your Emerson representative for details.

Series 65 Platinum RTD Temperature Sensors are highly linear and have a stable resistance versus temperature relationship. These sensors are used primarily in industrial environments where high accuracy, durability, and long-term stability are required. Series 65 Sensors are designed to meet the most critical parameters of international standards: IEC 751:1983, Amendment 1:1986 and 2:1995 and DIN EN 60751:1996. This standardization provides sensor interchangeability without the need for transmitter circuitry adjustment.

Enhanced performance and optimal temperature measurement accuracy is available for Series 65 Sensors coupled with a range of Rosemount Smart Temperature Transmitters through calibration schedules and Callendar-Van Dusen constants.

Series 185 Thermocouple Temperature Sensors conform to IEC 584:1982, Amendment 1:1989 and are available in types J, K and N. Series 185 Sensors are available single ungrounded, or dual ungrounded, isolated.

All sensors are available in a variety of lengths(1) and ranges with flying lead, terminal block, or 1/2-in. NPT spring-loaded adapter lead wire terminations.

In addition to complete assemblies, Emerson offers a selection of separate accessory hardware including connection heads and thermowells.

Selecting an extension and thermowell

Aside from ambient temperature variations, heat from the process, in a direct mounting configuration, is transferred from the thermowell to the transmitter housing. If the expected process temperature is near or beyond the transmitter specification limits, consider the use of additional thermowell extension length, an extension nipple, or a remote mounting configuration to isolate the transmitter from these excessive temperatures. Figure 1 provides an example of the relationship between transmitter housing temperature rise and extension length. Use Figure 1 and the accompanying example as a guide for determining adequate thermowell extension length.

Figure 1. Transmitter Housing Temperature Rise vs. Uninsulated Extension Length

Example

The rated ambient temperature specification for the transmitter is 85 °C. If the maximum ambient temperature is 40 °C and the temperature to be measured is 540 °C, the maximum allowable housing temperature rise is the rated temperature specification limit minus the existing ambient temperature (85 – 40 °F), or 45 °C.

As shown in Figure 1, an “N” dimension of 90 mm will result in a housing temperature rise of 22 °C. An “N” dimension of 100 mm would therefore be the minimum recommended length, and would provide a safety factor of about 25 °C. A longer “N” dimension, such as 150 mm, would be desirable in order to reduce errors caused by transmitter temperature effect, although in that case the transmitter may require extra support.

1. Sensors over one meter long will be supplied coiled unless otherwise requested.

60

50

40

30

20

10

0

75 100 125 150 175 200 225

815 °C Process Temperature

540 °C Process Temperature250 °C Process Temperature

Hou

sing

Ris

e A

bove

Am

bien

t (°C

)

Uninsulated Extension “N” Length (mm)

22 Emerson.com/Rosemount

Page 23: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Integral mount sensors and assemblies

Series 65 RTD and Series 185 Thermocouple Temperature Sensors may be ordered as complete assemblies, which provide a complete, yet simple, means of specifying the proper industrial hardware for most temperature measurements. One assembly model number, derived from one ordering table, completely defines the type of sensing element, as well as the material, length, and style of extension fittings and thermowells.

All sensor assemblies are sized and inspected by Emerson to ensure complete component compatibility and performance.

Mounting configurations

Series 65 Platinum RTDsand Series 185 Thermocouples

You may order the Series 65 RTDs and the Series 185 Thermocouples with flying leads, a terminal block, or a 1/2-in. NPT spring-loaded adapter.

Ordered with flying leads, the sensors are designed to be used with a head-mount temperature transmitter attached directly to the sensor. The flying lead configuration allows the removal of the sensor and transmitter as one assembly.

The BUZH connection head allows terminal block style sensors and transmitters to be mounted together. The transmitters in these assemblies will be mounted in the cover of the BUZH connection head.

The sensors with a 1/2-in. NPT spring-loaded adapter are used with directly mounted 3144P field-mount temperature transmitters or through the use of Rosemount connection heads. This assembly requires a terminal block to be mounted inside the head.

Hazardous area approvals are available with all three types of sensors, but they are dependent on the configuration of the entire temperature measurement assembly (see “Product Certifications” on page 26).

Temperature considerations

Ambient temperature limits for the connection head are –40 °C to +85 °C. The LT Option may be extended down to a range of –51 °C to +85 °C.

Ambient temperature range addresses the connection head only, and requires suitable cable glands and field wiring provisions to meet the temperature requirements below –40 °C.

Figure 2. Series 65 RTD Lead Wire Configuration

Figure 3. Series 185 Lead Wire Configuration

Series 65 RTD Flying Leads and spring-loaded adapter-termination codes 0 or 3 only

Single element Dual element

Series 65 RTD Terminal Block termination code 2

Single element Dual element(1)

1. The color of the terminal posts in the terminal block may not match the color of the lead wires connected to the capsule.

Series 185 RTD Thermocouple Terminal Block

Single element Dual element

White

White

Red

Red

Black

Blue

RedRed

Blue

Green

RedRed

White

White

43

1

6

1 3

46

Red

Red

White

3

2

1

Red

Red

White

6

5

4

12

3

45

6

1 3

3 (-)

1 (+)

46

6 (-)

4 (+)

3 (-)

1 (+)1 3

23Emerson.com/Rosemount

Page 24: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Specifications

Series 65 Platinum RTD

100 Ω RTD at 0 °C, α = 0.00385 °C-1

Temperature range

–50 to 450 °C or –196 to 300 °C depending on type

Self heating

0.15 °C/mW when measured per method defined inIEC 751:1983, Amendments 1 and 2

Thermal response time

9 seconds maximum required to reach 50 percent sensor response when tested in flowing water according to IEC 751:1983, Amendments 1 and 2

Immersion error

60 mm minimum usable depth of immersion when tested according to IEC 751:1983, Amendments 1 and 2

Insulation resistance

1,000 MΩ minimum insulation resistance when measured at 500 Vdc and at room temperature

Sheath material

316 SST sensor tip (hot end) with 321SST mineral insulated cable construction

Lead wire

PTFE insulated, silver-coated, 0.21mm2 (24 AWG) stranded copper wire. See Figure 2 for wire configuration.

Identification data

The model and serial numbers are marked on each sensor.

Ingress protection (IP) ratings

The Rosemount connection head is rated to IP66/IP68 and NEMA® 4X. The BUZ and BUZH connection heads are rated to IP65. To maintain IP rating at installation, one of the following options must be used with the connection head:

Extension and/or adapter and barstock thermowell

Tubular thermowell

Sensor and sealing screw (extension option “V”)

General purpose adapter

Vibration limits

For sensor types option code “1”, “2”, “3”, and “4”, the vibration resistance is ±0.02% (0.05 °C) maximum ice-point resistance shift after 3 g vibration between 10 and 500 Hz for 150 hours according to IEC 751:1983, Amendments 1 and 2.

For sensor types option code “7”, “9”, and “0”, the vibration resistance is ±0.02% (0.05 °C) maximum ice-point resistance shift after 10 g vibration between 10 and 500 Hz for 150 hours according to IEC 751:1983, Amendments 1 and 2.

Table 5. Series 65 Interchangeability

Standard series 65 IEC-751 class B Temperature

±0.80 °C (±1.44 °F) –100 °C (–148 °F)

±0.30 °C (±0.54 °F) 0 °C (32 °F)

±0.80 °C (±1.44 °F) 100 °C (212 °F)

±1.80 °C (±3.24 °F) 300 °C (572 °F)

±2.30 °C (±4.14 °F) 400 °C (752 °F)

Series 65 with IEC-751 class A option Temperature

±0.35 °C (±0.63 °F) –100 °C (–148 °F)

±0.15 °C (±0.27 °F) 0 °C (32 °F)

±0.35 °C (±0.63 °F) 100 °C (212 °F)

±0.75 °C (±1.35 °F) 300 °C (572 °F)

24 Emerson.com/Rosemount

Page 25: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Series 185 Thermocouple

Construction

A thermocouple consists of a junction between two dissimilar metals that produces a change in thermoelectric emf in relationship to a change in temperature. Rosemount Series 185 thermocouple sensors are manufactured from selected materials to meet IEC 584 Tolerance Class 1. The junction of these wires is welded to form a pure joint, maintaining the integrity of the circuit and ensuring the highest accuracy. Ungrounded junctions are protected from the environment by the sensor sheath. The ungrounded and isolated junctions provide electrical isolation from the sensor sheath.

Sheath material

Rosemount thermocouples are made of a mineral insulated cable design with a variety of sheath materials available to suit both the temperature and the environment. For temperatures up to 800 °C in air, 1.4541 (321 SST) is standard. For temperatures from 800 to 1100 °C in air, 2.4816 (Alloy 600) is standard. For temperatures above 1100 °C, precious metal or ceramic protective sheaths are available upon request. For strongly oxidising or reducing atmospheres, consult your local Emerson representative.

Lead wires

PTFE insulated, 0.52 mm2 (20 AWG) stranded thermocouple wire. Color coded per IEC 584. See Figure 3 for wire configuration.

Identification data

The model and serial numbers are marked on each sensor.

Insulation resistance

1,000 MΩ minimum insulation resistance when measured at 500 Vdc and at room temperature.

Ingress protection (IP) ratings

The Rosemount connection head is rated to IP66/IP68 and NEMA 4X. The BUZ and BUZH connection heads are rated to IP65. To maintain IP rating at installation, one of the following options must be used with the connection head:

Extension and/or adapter and barstock thermowell

Tubular thermowell

Sensor and sealing screw (Extension option “V”)

General purpose adapter

Material selection

Emerson provides a variety of Rosemount product with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser’s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product, materials, options and components for the particular application. Emerson is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration or materials of construction selected.

Table 6. Characteristics of Series 185 Thermocouples

Type Alloys (wire color) Sheath material Temp. range (°C)Limits of error (°C)

(whichever is greater)Tolerance

class

J Fe (+ black), CuNi (– white) 1.4541 (321 SST) –40 to 750 ±1.5 or ±0.4% 1

K NiCr (+ green), NiAl (– white) 2.4816 (Alloy 600) –40 to 1000 ±1.5 or ±0.4% 1

N NiCrSi (+ pink), NiSi (– white) 2.4816 (Alloy 600) –40 to 1000 ±1.5 or ±0.4% 1

25Emerson.com/Rosemount

Page 26: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Product CertificationsRev 1.15

European Directive information

A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount.

Ordinary Location Certification

As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

North America

The US National Electrical Code® (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes.

Hazardous locations certifications

USA

E5 FM Explosion-proof and Dust-Ignition-proofCertificate: FM17US0170XStandards: FM Class 3600: 2011; FM Class 3611: 2004; FM

Class 3615: 2006; FM Class 3810: 2005; ANSI/NEMA® - 250: 1991

Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; T5 (–50 °C ≤ Ta ≤ +85 °C); Type 4X

Canada

E6 CSA Explosion-proof and Dust-Ignition-proofCertificate: 1063635Standards: CSA C22.2 No. 0-M91; CSA C22.2 No. 25-1966;

CSA C22.2 No. 30-M1986; CSA C22.2 No. 94-M91; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987

Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL I, Div 2, GP A, B, C, D; (–50 °C ≤ Ta ≤ +85 °C)

Europe

E1 ATEX Flameproof Certificate: FM12ATEX0065X Standards: EN60079-0:2012+A11:2013; EN60079-1:2014Markings: II 2 G Ex d IIC T6...T1 Gb, T6(–50 °C ≤ Ta ≤

+40 °C), T5...T1 (–50 °C ≤ Ta ≤ +60 °C)

Special Conditions for Safe Use (X):

1. See certificate for ambient temperature range.

2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.

3. Guard the LCD display cover against impact energies greater than 4 joules.

4. Flameproof joints are not intended for repair.

5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option “N”.

6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.

7. Non-Standard Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information.

I1 ATEX Intrinsic SafetyCertificate:Baseefa16ATEX0101XStandards: EN 60079-0:2012+A11:2013, EN

60079-11:2012Markings: II 1 G Ex ia IIC T5/T6 Ga (see certificate for

schedule)

Special Condition for Safe Use (X):

1. The equipment must be installed in an enclosure which affords it a degree of ingress protection of at least IP20.

N1 ATEX Type n Certificate: BAS00ATEX3145Standards: EN 60079-0:2012, EN 60079-15:2010Markings: II 3 G Ex nA IIC T5 Gc (–40 °C ≤ Ta ≤ +70 °C)

Thermocouples; Pi = 500 mW T6 60 °C ≤ Ta ≤ +70 °C

RTDs; Pi = 192 mW T6 60 °C ≤ Ta ≤ +70 °C

RTDs; Pi = 290 mWT6 60 °C ≤ Ta ≤ +60 °C

T5 60 °C ≤ Ta ≤ +70 °C

26 Emerson.com/Rosemount

Page 27: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

ND ATEX DustCertificate: FM12ATEX0065X Standards: EN 60079-0:2012+A11:2013; EN 60079-31:

2014Markings: II 2 D Ex tb IIIC T130 °C Db (–40 °C ≤ Ta ≤

+70 °C)

Special Conditions for Safe Use (X):

1. See certificate for ambient temperature range.

2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.

3. Guard the LCD display cover against impact energies greater than 4 joules.

4. Flameproof joints are not intended for repair.

5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option “N”.

6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.

7. Non-Standard Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information.

International

E7 IECEx FlameproofCertificate: IECEx FMG 12.0022XStandards:IEC60079-0:2011, IEC60079-1:2014-06Markings: Ex d IIC T6...T1 Gb, T6(–50 °C ≤ Ta ≤ +40 °C),

T5…T1(–50 °C ≤ Ta ≤ +60 °C)

Special Conditions for Safe Use (X):

1. See certificate for ambient temperature range.

2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.

3. Guard the LCD display cover against impact energies greater than 4 joules.

4. Flameproof joints are not intended for repair.

5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option “N”.

6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.

7. Non-Standard Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information.

Brazil

E2 INMETRO FlameproofCertificate: UL-BR 13.0535XStandards: ABNT NBR IEC 60079-0: 20013; ABNT NBR IEC

60079-1: 2016; ABNT NBR IEC 60079-31:2014Markings: Ex db IIC T6...T1* Gb T6…T1*: (–50 °C ≤ Ta ≤

+40 °C), T5...T1*:(–50 °C ≤ Ta ≤ +60 °C) Ex tb IIIC T130 °C Db (–40 °C ≤ Ta ≤ +70 °C)

Special Conditions for Safe Use (X):

1. See product description for ambient temperature limits and process temperature limits.

2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.

3. Guard the LCD display cover against impact energies greater than 4 joules.

4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.

5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option “N”.

6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.

Japan

E4 Japan Flameproof (0065 only)Certificate: TC17226Markings: Ex d IIC T6; (–20 °C ≤ Ta ≤ +65 °C); Process

Temperature: –20 °C to +85 °C

Special Condition for Safe Use (X):

1. The wiring shall be suitable for a temperature over 80 °C.

EAC – Belarus, Kazakhstan, Russia

EM Technical Regulation Customs Union (EAC) FlameproofMarkings: 1Ex d IIC T6…T1 Gb X

Special Condition for Safe Use (X):

1. See certificate for special conditions.

IM Technical Regulation Customs Union (EAC) Intrinsic SafetyMarkings: 0Ex ia IIC T5, T6 Ga X

Special Condition for Safe Use (X):

1. See certificate for special conditions.

KM Technical Regulation Customs Union (EAC) Intrinsic SafetyMarkings: Ex tb IIIC T 130 °C Db X plus EM and IM markings

above

Special Condition for Safe Use (X):

1. See certificate for special conditions.

27Emerson.com/Rosemount

Page 28: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Korea

EP Korea Explosionproof/FlameproofCertificate: 13-KB4BO-0560XMarkings: Ex d IIC T6…T1; T6(–50 °C ≤ Tamb ≤ +40 °C),

T5…T1(–50 °C ≤ Tamb ≤ +60 °C)

Special Condition for Safe Use (X):

1. See certificate.

Combinations

KD Combination of E1, E5, and E6

K1 Combination of E1, I1, N1, and ND

KM Combination of EM and IM

28 Emerson.com/Rosemount

Page 29: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

NoteRefer to Table 7 to determine which approvals are available with each connection head option code.

Table 7. Available Safety Approvals with Model Code Options

Model code Description Conduit entry

Approval code

I1 N1 E1 E2 ND E7 E5 E4 E6 KD

C Rosemount aluminum M20 � 1.5 Y Y Y Y Y Y Y N N N

D Rosemount aluminum 1/2-in. NPT Y Y Y Y Y Y Y Y Y Y

1Rosemount aluminum with LCD display meter cover

M20 � 1.5 Y Y Y Y Y Y Y N N N

2Rosemount aluminum with LCD display meter cover

1/2-in. NPT Y Y Y Y Y Y Y N Y Y

N No connection head N/A Y Y Y Y Y Y Y N Y Y

G Rosemount stainless steel M20 � 1.5 Y Y Y Y Y Y Y N N N

H Rosemount stainless steel 1/2-in. NPT Y Y Y Y Y Y Y N Y Y

J GR–A/BL (BUZ) aluminum with cable gland M20 � 1.5 Y N N N N N N N N N

L BL (BUZH) aluminum with cable gland M20 � 1.5 Y N N N N N N N N N

7 Aluminum dual entry head 2 � 3/4-in. NPT Y N Y N N N N N N N

8 Aluminum dual entry head 2 � M20 � 1.5 Y N Y N N N N N N N

9 Aluminum dual entry head 2 � 1/2-in. NPT Y N Y N N N N N N N

K Stainless steel dual entry head 2 � 3/4-in. NPT Y N Y N N N N N N N

R Stainless steel dual entry head 2 � M20 � 1.5 Y N Y N N N N N N N

W Stainless steel dual entry head 2 � 1/2-in. NPT Y N Y N N N N N N N

A TZ–A/BL (BUZH) aluminum coated M20 � 1.5 Y N N N N N N N N N

P SD–BK M20 � 1.5 Y N N N N N N N N N

Z ZW–BL M20 � 1.5 Y N N N N N N N N N

G1 External ground screw N/A Y N Y N N N Y N Y N

G6Aluminum extension ring for dual transmitter mounting

N/A Y N Y N N N N N N N

29Emerson.com/Rosemount

Page 30: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Sensor-to-Transmitter Matching Significant measurement accuracy improvements can be attained using a temperature sensor that is matched to a temperature transmitter. This process involves identifying the relationship between resistance and temperature for a specific RTD sensor. This relationship, approximated by the Callendar-Van Dusen equation, is described as:

Rt = Ro + Roα[t – δ(0.01t – 1)(0.01t) – β(0.01t – 1)(0.01t)3],

where:

Rt = Resistance (ohms) at Temperature t (°C)

Ro = Sensor-Specific Constant (Resistance at t = 0 °C)

α = Sensor-Specific Constant

δ = Sensor-Specific Constant

β = Sensor-Specific Constant (0 at t > 0 °C)

The exact values for the Callendar-Van Dusen constants (Ro, α, δ, β) are specific to each RTD sensor and are established by testing each individual sensor at various temperatures.

Series 65 RTD sensors can be ordered with the Calibration Option codes V10 or V11, where the values of all four sensor-specific constants are supplied with each sensor.

The transmitter uses the Callendar-Van Dusen constants to generate a sensor curve that describes the relationship between resistance and temperature for this particular sensor and transmitter assembly. By using the sensors actual resistance vs. temperature curve, there is a 3- or 4-fold improvement in temperature measurement accuracy for the total system.

Options V10 and V11 are specific to a particular temperature range. As with calibration schedules, the accuracies associated with each option code represent worst-case conditions when the sensor is used over the entire temperature range. The accuracy of Series 65 sensors with the “V” option will vary because they have different hysteresis and repeatability characteristics. To ensure optimal performance, select a “V” option where the sensor’s range of actual operation is between the minimum and maximum calibration points. For applications requiring the use of a Resistance vs. Temperature Table, order a temperature range-specific characterization schedule.

IEC 751 interpretation

The Callendar-Van Dusen equation is one method of describing the resistance versus temperature (R vs.T) relationship for platinum RTDs. International standard IEC 751 interprets the R vs. T relationship using an approach similar to the Callendar-Van Dusen methodology. The IEC 751 R vs.T relationship standard uses the following equation:

Rt = Ro[1 + At + Bt2 + C (t – 100)t3]

As in the Callendar-Van Dusen method, Ro, A, B, C are specific to each RTD and are established by testing each sensor at various temperatures. The actual values for A, B, and C differ in magnitude from the Callendar-Van Dusen constants (Ro, α, β, δ), while Ro is the same in both equations. Either methodology yields the same result in any sensor-to-transmitter matching scenario, since one equation is a simple mathematical interpretation of the other.

30 Emerson.com/Rosemount

Page 31: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Typical sensor–to–transmitter matching accuracy improvements

Transmitter: Rosemount 3144P (has built-in sensor matching capabilities), span of 0 to 200 °C, accuracy = 0.1 °C)

Sensor: Series 65 RTD

Callendar-Van Dusen option: V10

Process temperature: 150 °C

Figure 4. System Uncertainty Comparison at 150 °C

Calibration

Sensor calibration may be required for input to quality systems, or for control system enhancement. More frequently, it is used to improve the overall temperature measurement performance by matching the sensor to a temperature transmitter. Sensor matching is available for RTD sensors used with Rosemount Smart transmitters where the inherent stability and repeatability of the RTD technology is well established.

Ordering information

Use the formats presented below to order a calibrated series 65 RTD. If you fail to specify all of the necessary calibration-related information when you place your order, Emerson will contact you for the information and your order may be delayed slightly.

Measurement instrument directive parts certification

The Rosemount 3144P Temperature Transmitter and Rosemount 0065 Temperature Sensor have been certified to meet the European Union measurement instrument directive (MID) for custody transfer metering of liquids and gases.(1) Choosing Rosemount temperature for a MID solution ensures that critical temperature measurement equipment will meet high expectations for unmatched system accuracy and reliability. For more information, contact your local Emerson Representative.

Calibration options

The X8 option calibrates the sensor to a customer-specific temperature range. The Callendar-Van Dusen, and A, B, and C-constants are supplied with a works certificate.

Standard 65 Sensor

Rosemount 3144P: ± 0.10 °C

Standard series 65 RTD: ± 1.05 °C

Total system(1):

1. Calculated using RSS statistical method:

± 1.05 °C

65 Sensor with V10 Option

Rosemount 3144P: ± 0.10 °C

Calibrated sensor series 65 RTD: ± 0.18 °C

Total system(1): ± 0.21 °C

1.0 °C

0.75 °C

0.5 °C

Standard With SensorMatching

System accuracy = TransmitterAccuracy( )2 SensorAccuracy( )2+

1. Calculated using RSS statistical method: System accuracy = TransmitterAccuracy( )2 SensorAccuracy( )2+

31Emerson.com/Rosemount

Page 32: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Option X8: sensor calibrated to a customer-specified temperature range (see Temperature range )

When you order an RTD with the X8 option, the temperature range the sensor needs to be calibrated must be specified. Take note of the sensor temperature limits as shown below:

NoteCalibrate from –10 to 120 °C.

Table 8. Typical Model Number

Model Connection head Lead wire termination Sensor type Extension type

0065 C 2 1 D

Extension length Thermowell material Immersion length Mounting style Additional options

0135 D 0225 T12 X8

Table 9. Option V: Sensor Calibration with Works Certificate

Code

V10 V11 V16

Temperature range (°C) –50 to +450 0 to +100 –50 to +100

Calibration points (°C) –50 0

+100+450

0+50

+100

–50 0

+50+100

32 Emerson.com/Rosemount

Page 33: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

33Emerson.com/Rosemount

Figure 5. Sensor Assembly Without Thermowell

Rosemount 644 with LCD display meter

Rosemount 644 Rosemount 248

Head or field mount transmitters

IP68 or IP65 connection heads

Sensor with flying leads, terminal block, or spring-loaded adapter

Extensions

★★ N dimension measures from thread engagement point

40 mm

3144

25 mm

16 mm11 mm

L

L L

N★★N★★

N★★

Page 34: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

34 Emerson.com/Rosemount

Figure 6. Series 65 RTD and Series 185 Thermocouple Dimensional Drawings

Dimensions are in millimeters.

ATEX/CENELEC EEx d flameproof and IECEx/FM explosion-proof approved

Non-approved1/2- NPT spring loaded

adapter

Terminal block Flying leads Terminal block Flying leads

11±2

L

41

33

21

8.00

L

41

33

21

8.00

L

41

33

9.0

8.0

L

41

9.0

8.0

L

33

Table 10. Additional Dimensions for Series 65 RTD and Series 185 Thermocouple

Series Sensor diameter Number of leads

Lead wire length (flying leads)

Lead wire length (spring loaded)

Element 1 Element 2 Element 1 Element 2

65 Single element 6.0 4 150 N/A 150 N/A

65 Dual element 6.0 6 150 200 150 200

185 Single element 6.0 2 100 N/A 150 N/A

185 Dual element 6.0 4 100 200 150 200

Page 35: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Figure 7. Tubular Thermowell Sensor Assemblies

Rosemount 644 with LCD display meter

Rosemount 644 Rosemount 248

Head or field mount transmitters

IP68 or IP65 connection heads

Sensor with flying leads or terminal block

Threaded and flangedtubular thermowells

★★ For straight threading, N dimension references bottom of hex.For tapered threading, N dimension references thread engagement point (bottom of thread).

40 mm 25 mm

★★

NN N

UU U

U

NAMURNAMUR GB GN

★★★★

Table 11. Tubular Thermowell Ratings

Type DimensionsProcess

connection

Max. flow velocity(m/s)

Immersion length (mm)

Max. pressure (bar)

At temperature (°C)

Air Water At 0 °C 100 200 300 400

GN GB

9 � 1 mm 1.4571 (316 Ti)

Screw socket G1/2

25 3

160 50 48 44 40 36

250 40 40 40 40 36

400 18 18 18 18 18

GN 11 � 2 mm

1.4571(316 Ti)

Screw socket G1

40 5

160 100 95 92 88 80

250 50 50 50 50 50

400 18 18 18 18 18

35Emerson.com/Rosemount

Page 36: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

NAMUR12 � 2.5 mm

1.4571(316 Ti)

Screw socket G1

40 5

160 100 100 100 100 100

220 100 100 100 78 78

280 100 100 100 55 55

Table 11. Tubular Thermowell Ratings

Type DimensionsProcess

connection

Max. flow velocity(m/s)

Immersion length (mm)

Max. pressure (bar)

At temperature (°C)

Air Water At 0 °C 100 200 300 400

36 Emerson.com/Rosemount

Page 37: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Figure 8. Barstock Thermowell Sensor Assemblies

Rosemount 644 with LCD display meter

Rosemount 644 Rosemount 248

Head or field mount transmitters

IP68 or IP65 connection heads

Sensor with flying leads, terminalblock, or spring-loaded adapter

Stand-alone extensions

Weld-in, threaded, or flanged barstock thermowells

★★ N dimension measures from thread engagement point.★★★ This dimension is 80 mm for 1500# and 2500# flanges.

40 mm 25 mm

N★★

L

3144

L

L

11 mm

11 mm

11 mm

11 mm

N★★

N★★

16 mm

T

U

U

60 mm 60 mm

U

40 mm

U

60 mm★★★

U

37Emerson.com/Rosemount

Page 38: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Accessories

Figure 9. Connection Head Dimensional Drawing

Table 12. Connection Head

Part number Model/material IP rating Conduit connectionProcess

connection

00644-4410-0011 Rosemount aluminum 66/68 1/2-in. NPT 1/2-in. NPT

00644-4410-0013 Rosemount aluminum 66/68 1/2-in. NPT M24 � 1.5

00644-4410-0021 Rosemount aluminum 66/68 M20 � 1.5 1/2-in. NPT

00644-4410-0023 Rosemount aluminum 66/68 M20 � 1.5 M24 � 1.5

00644-4410-0111 Rosemount aluminum with LCD display cover 66/68 1/2-in. NPT 1/2-in. NPT

00644-4410-0113 Rosemount aluminum with LCD display cover 66/68 1/2-in. NPT M24 � 1.5

00644-4410-0121 Rosemount aluminum with LCD display cover 66/68 M20 � 1.5 1/2-in. NPT

00644-4410-0123 Rosemount aluminum with LCD display cover 66/68 M20 � 1.5 M24 � 1.5

00644-4411-0011 Rosemount stainless steel 66/68 1/2-in. NPT 1/2-in. NPT

00644-4411-0013 Rosemount stainless steel 66/68 1/2-in. NPT M24 � 1.5

00644-4411-0021 Rosemount stainless steel 66/68 M20 � 1.5 1/2-in. NPT

00644-4411-0023 Rosemount stainless steel 66/68 M20 � 1.5 M24 � 1.5

00644-4196-0023 GR–A/BL (BUZ), aluminum 65 M20 � 1.5 M24 � 1.5

00644-4197-0023 TZ–A/BL (BUZH), aluminum 65 M20 � 1.5 M24 � 1.5

With LCD display cover With standard cover TZ–A/BL (BUZH) GR–A/BL (BUZ)

Option codes 1, 2 Option codes C, D, G, H Option code L Option code J

A. Head connectionB. LCD displayC. Cable entryDimensions are in millimeters.

104

78

128

B

A

4.1 (104)

78

4 (100)

118

110C

A

118

84C

A

38 Emerson.com/Rosemount

Page 39: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Series 96 Barstock Thermowells

Figure 10. Flanged Barstock Thermowell – Tapered

Note: Flanged thermowells generally conform to the specifications of ASME B 16.5 (ANSI) and DIN EN 1092-1.

Figure 11. Threaded Barstock Thermowell – Parallel Thread

Figure 12. Threaded Barstock Thermowell – Tapered Thread

Flange size D d T

1-in. 150–1500 lb, DN 25 19 12.5 60

11/2 to 2-in. 150–600 lb, DN40–50 26.5 18 60

1.5 to 2-in. 900/1500 26.5 18 80

U. Immersion lengthD. Stem diameter

T. Lagging length

Dimensions are in millimeters.

Parallel thread size D D1 d

1/2-in. BSPF (G1/2); M20 � 1.5 17 26 12.5

3/4-in. BSPF (G3/4) 19 32 12.5

1-in. BSPF (G1) 26.5 39 18

M24 � 1.5 19 29 12.5

U. Immersion length D. Stem diameter

Dimensions are in millimeters.

Tapered thread size D d

1/2-in. NPT; M20 � 1.5 17 12.5

3/4-in. NPT 19 12.5

1-in. NPT 26.5 18

U. Immersion length D. Stem diameter

Dimensions are in millimeters.

T U

D d 6.5

5.0

40 U

D D1

5.0

6.5

d

60 U

D d

6.5

5.0

39Emerson.com/Rosemount

Page 40: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric) March 2019

Figure 13. Weld-In Barstock Thermowell (Codes W10, W12, W14, W16)

Figure 14. Weld-in Barstock Thermowell (Codes E01, E02, E04, E05)

Socket size S D d

3/4-in. 26.7 19.0 12.5

1-in. 33.4 19.0 12.5

11/4-in. 42.2 19.0 12.5

11/2-in. 48.3 19.0 12.5

U. Immersion length D. Stem diameter

Dimensions are in millimeters.

Previous DIN form D1 D2 D4 D5 d

TL 140 200 200 260 12.5

U 65 125 65 125 12.5

T 75 75 135 135 12.5

U. Immersion lengthTL. Total length

T. Lagging length

Dimensions are in millimeters.

UT60 U

S D5.0 6.5

d

UT

TL

24h7

5.0

6.5 d

40 Emerson.com/Rosemount

Page 41: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Sensor and Accessories (Metric)March 2019

Wake frequency calculation

Pressure and flow vibration

The strength of a thermowell depends on several parameters relating thermowell construction to the installation environment. For most industrial applications, standard Rosemount thermowells provide the necessary strength if the material, style, and length are correct for the application. The proper selection of a thermowell depends on fluid type, temperature, pressure, and fluid velocity. Most thermowell failures are caused by vibration that is induced by fluid flow.

Emerson has a design system for the correct selection of thermowells. This selection service is available for a nominal charge, and to take advantage of this service, complete and return the Wake Frequency Calculation Configuration Data Sheet to your local Emerson representative.

41Emerson.com/Rosemount

Page 42: Product Data Sheet: Rosemount DIN-Style Temperature ... · 2 Sensor and Accessories (Metric) March 2019 Emerson.com/Rosemount Rosemount DIN-Style Temperature Sensor and Thermowells

Product Data SheetMarch 2019

Sensor and Accessories (Metric)00813-0200-2654, Rev LB

Global HeadquartersEmerson Automation Solutions6021 Innovation Blvd.Shakopee, MN 55379, USA

+1 800 999 9307 or +1 952 906 8888+1 952 949 7001 [email protected]

North America Regional OfficeEmerson Automation Solutions8200 Market Blvd.Chanhassen, MN 55317, USA

+1 800 999 9307 or +1 952 906 8888+1 952 949 7001 [email protected]

Latin America Regional OfficeEmerson Automation Solutions 1300 Concord Terrace, Suite 400Sunrise, FL 33323, USA

+1 954 846 5030+1 954 846 [email protected]

Europe Regional OfficeEmerson Automation Solutions Europe GmbHNeuhofstrasse 19a P.O. Box 1046CH 6340 BaarSwitzerland

+41 (0) 41 768 6111+41 (0) 41 768 6300 [email protected]

Asia Pacific Regional OfficeEmerson Automation Solutions 1 Pandan CrescentSingapore 128461

+65 6777 8211+65 6777 0947 [email protected]

Middle East and Africa Regional OfficeEmerson Automation SolutionsEmerson FZE P.O. Box 17033Jebel Ali Free Zone - South 2Dubai, United Arab Emirates

+971 4 8118100+971 4 8865465 [email protected]

Linkedin.com/company/Emerson-Automation-Solutions

Twitter.com/Rosemount_News

Facebook.com/Rosemount

Youtube.com/user/RosemountMeasurement

Google.com/+RosemountMeasurement

Emerson Terms and Conditions of Sale are available upon request.The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.© 2019 Emerson. All rights reserved.