Upload
charles1010
View
1.482
Download
1
Tags:
Embed Size (px)
DESCRIPTION
This is the presentation for our sister company that engages with clients with data center requirements. It is the same people i.e Lima staff!
Citation preview
Datacentre UK and APC | MGE
Technology Partnership
Agenda
Introduction to Datacentre UK and APC
Main Presentation, covering APC Data Centre’s
Questions
Datacentre Uk
Total IT Solutions provider
APC Gold PartnerMicrosoft Gold PartnerHP Preferred PartnerIBM Systems Reseller
APC Product Portfolio
Desktop
$3.46Billion
1984 1986 1992 1995 1996
ISX Introduction: World’s first integrated NCPI system
Symmetra MW: World’s largest
static UPS system
Introduced SymmetraTM
Power ArrayR
1997 1998 2000 2001
World’s #1 Provider Network
UPS Systems
World’s First Web-
Manageable UPS
3-Phase Acquisition
Sil LOGO
Network Cooling:
Acquisition
ServerNetworking
Data Center
Top 5 Datacentre Imperatives.
APC asked the questions – customers replied:-
Controlling total life cycle costs.Adapting to ever changing I.T business demands.Availability 7x24x365 basis without critical failure.Equipment manageability locally and remotely.Easy and fast maintainability of equipment.
InfraStruXureTM from APC. what is it ?
A patented, integrated system for power, cooling, and management for data/computer rooms.
Designed using a modular, scalable, and pre-engineered approach
Enables IT managers to select a variety of standardized components to create a customized solution.
Provides the reliability, affordability, and predictability of standardized solutions yet is completely customized.
POWER
Symmetra PX 80 Product Design Benefits
Premium Line-Up and Match External Battery Enclosure
A total of four (4) enclosures can be connected to the UPS for extended runtimes
Dual Mains Input/Output
Allows for connection to 2 seperate power inputs for increased avilability
Symmetra PX
Battery Module
Connected in parallel for increased availability and hot swappable for easy replacement by a trained user
Built-in Static Bypass Switch
Enables the UPS to transfer the load to utility power, without interruption, in case of heavy overload or faulty conditions
Redundant Intelligence Module
Back-up for the Main Intelligence Module provides increased availability
Power Module
Provides the flexibility to scale power capacity and adds N+1 capability as well as includes a fully rated inverter for providing more real power
InfraStruXure ® PDU Product Design Benefits
Aesthetic DesignDesigned in rack form to integrate seamlessly with your IT equipment while providing a high power density
NEMA Rated TP1 Transformers Reduces your running costs & minimizes your TCO by utilizing the most efficient transformers in the industry
Integrated Maintenance Bypass (40 kW & 80kW)Simplifies system maintenance and maintains data center operation should you take your UPS off-line
Custom Configurable & TestedFast, fault-free installation ensuring your data center is up and running in the shortest possible time
Overhead & Under Floor Cable Distribution Flexibility & PDU Uniformity regardless of the cabling distribution employed across your data centers
Front or Rear Access for ServiceNo end of row requirement
RACKS
NetShelter® SX
World’s most versatile rack enclosure for demanding IT environments
Enclosures providing cooling, power distribution, cable management, and environmental monitoring for applications in IT environments
42U x 600mm 42U x 750mm 48U x 600mm 48U x 750mm
COOLING
Cooling
The closer you can couple the cooling solution to the heat source, the more effective the cooling is.
Air is the heat transfer medium. The more effectivly cool air is delivered to the server and hot air is removed back to the CRAC unit, the better the heat transfer.
Cooling SolutionsMost complete range of cooling solutions for the IT Environment
Cooling SolutionsCooling Solutions for the IT Environment
NetworkAIR FM/
NetworkAIR IR
Inrow RC &
Inrow SC/ RP
Chilled water/
DX
Air Distribution/Fans Computer Room Air Conditioning
Rack Air
Distribution Unit
Rack Air
Removal Unit
Side Air
Distribution Unit
Hot Aisle
Containment
InRow RP/ RC Airflow
InfraStruXure® InRow RP
InRow RP (600m)or RC(300m)
cooling units
Hot aisle air enters from rear
Heat captured and rejected to chilled
water or refrigerant
Cold air delivered to cold aisle
Can operate on hard or raised floor
InRow RP Chilled Water Product Design Benefits
Top or Bottom Piping Connections
Condensate Management
Detects and removes condensation
Cooling Coil
Removes heat using chilled water or refrigerant
Electric Reheat
Controls temperature during dehumidification
Steam Humidifier
Maintains moisture level in room
Casters
Allows unit to moved easilyInfraStruXure® InRow RP
Air Filter
Removes airborne particles, protects coil
Variable Speed Fans
Reduce energy consumption during off-peak cooling periods
InfraStruXure High Density
In-row with Hot Aisle Containment System (HACS)
The predictable solution for an unpredictable environment
Temperature (deg C)
Hot Aisle Containment System – The Ultimate in Predictable Performance
Equipment racks take inambient air from front
Ambient-temperature air is returned to room
Hot aisle
All exhaust air is captured within chamber and
“neutralised” to ambient temperature
Integral rackair conditioner
Integral rack power distribution system (UPS is
optional)
Can operate on hard floor or raised floor
Door access to hot aisle and rear of IT equipment
Half Rack Wide
Chilled Water 17kW* Capacity @ 29.4oC EAT, 7oC EWT 1274 l/s air flow Variable Speed Fans Modular
- Laterally Stackable – High Density & Redundancy- Between Racks- End of Row
Global Product
kW Metering**
Network Manageable ISX Manager Integration
RC In Row
* Rating point 11C delta T on IT equipment** kW = (deltaT x 4.2 x l/s) - (motor heat + latent)
Second Generation In Row Cooling Solutions
MANAGEMENT
Security & Environmental
InfraStruXure® Central v4.0Centralized management platform that includes real-time monitoring and
immediate event notification for quick assessment and resolution of critical situations. Extensible platform grows with your business.
InfraStruXure Central v4.0 Related Products
NetBotz EnvironmentalDetect and alarm on environmental factors which threaten the availability of your network-critical physical infrastructure
NetBotz SurveillanceMonitor and record all activity in secured areas. Recorded data can be easily reviewed, searched, and tagged for future needs.
NetBotz Accessories & Sensors Extend the capabilities of your environmental and security monitoring appliances.
APC Security & Environmental Monitoring
Protect your network-critical infrastructure from physical and environmental threats
InfraStruXureTM Summary
Changing the way the world designs data centers…
SPEED: Design & build a data center in 4 days versus 400 days
AVAILABILITY: Eliminates the need for 2 UPS systems
ADAPTABILITY: Scale, customize, or move system to meet changing demands
COST: Lower your upfront and operating expenses
"Thanks to APC and InfraStruXure™, we were able to centralize a uniform IT infrastructure and to significantly reduce our overall equipment and management costs.”
- Eric Ubels, Deloitte & Touche
Rack-based architecture for power, cooling, and environmental management
InfraStruXure™
Rack-based architecture for power, cooling, and environmental management
Changing the way the world designs data centres…InfraStruXure™
Symmetra PX
InfraStruXure PDU
NetShelter VX
NetworkAIR FM
Closets (1-3 Racks) Small Data Centres (5-20 racks)
Smart-UPS
NetShelter VX
NetworkAir PA
InfraStruXureTM
Computer Rooms (1-5 Racks)
Symmetra RM
NetShelter VX
NetworkAir PA
Symmetra PX
InfraStruXure PDU
NetShelter VX
NetworkAIR FM
Medium Data Centres (20-100 racks) Large Data Centres (>100 racks)
Symmetra MW
InfraStruXure PDU
NetShelter VX
NetworkAIR FM
InfraStruXure™ for:
Data Centres on Demand
Frequent IT changes create chaos resulting in human error
They were not planned at all
These systems were not planned to look like this
Video Presentation
Are You headed for a Data Centre Disaster?
Any Questions ?
Thankyou