13
Power Losses due to Button and Reentrant BPMs Igor Zagorodnov and Dirk Lipka 01.10.07 BD meeting, DESY

Power Losses due to Button and Reentrant BPMs

  • Upload
    ulfah

  • View
    39

  • Download
    0

Embed Size (px)

DESCRIPTION

Power Losses due to Button and Reentrant BPMs. Igor Zagorodnov and Dirk Lipka 01.10.07 BD meeting, DESY. Button BPM. gap=1mm. Accuracy Test of CST Microwave Studio -> OK. Gaussian bunch with sigma=2mm. Loss = 0.05 kV/nC. Kick = 0.2 kV/nC/m. BPM with Microwave Studio. - PowerPoint PPT Presentation

Citation preview

Page 1: Power Losses due to  Button and Reentrant BPMs

Power Losses due to Button and Reentrant BPMs

Igor Zagorodnov and Dirk Lipka

01.10.07

BD meeting, DESY

Page 2: Power Losses due to  Button and Reentrant BPMs

Button BPM

Page 3: Power Losses due to  Button and Reentrant BPMs

gap=1mm

-5 0 5-0.1

-0.05

0

0.05

0.1

0.15MWS(automesh)ECHO(sigma/10)

Gaussian bunch with sigma=2mm

Loss = 0.05 kV/nC

Kick = 0.2 kV/nC/m

-5 0 5-0.2

0

0.2

0.4

0.6MWS(automesh)ECHO(sigma/10)

Accuracy Test of CST Microwave Studio -> OK

||kV

nCW

kV

nC*mW

/s /s

Page 4: Power Losses due to  Button and Reentrant BPMs

-5 0 50

0.1

0.2

0.3

0.4

-5 0 5-0.06

-0.04

-0.02

0

0.02

0.04

Gaussian bunch with sigma=1mm

Loss = 0.047 kV/nC

Kick = 0.13 kV/nC/m

BPM with Microwave Studio

||kV

nCW

kV

nC*mW

/s /s

Gaussian bunch with sigma=25mkm

Loss = 0.3 kV/nC

Kick = 0.02 kV/nC/m

0.5Loss ( )O

0.5Kick ( )O

Page 5: Power Losses due to  Button and Reentrant BPMs

Rotationally symmetric model with ECHO(as an estimation from above)

0 2 40

1

2

3

4

5

g=1mm

sigma,

m

Loss,

kV/nC

Kick,

kV/nC/m

2000 0.11 0.44

100 0.77 0.143

25 1.68 0.076

0.5Loss ( )O 0.5Kick ( )O

Analytical estimation (K.Bane, Sands M., SLAC-PUB-4441, 1987)

0|| 2

( )2

Z c gw s

sa

a=39mm

02 2

22( )

Z cw s gs

a a

03 2.5

2 3Kick

4

Z cg

a

02.5

1Loss

44

Z c g

a

Page 6: Power Losses due to  Button and Reentrant BPMs

3250 [ ]bN bunches

30 [ ]repf Hz

1[ ]q nC

2b rep lossP N f q k

0.16geomP W

Power Loss

kVfor 1.68

nClossk (upper level, round approx.)

0.03geomP WkV

for 0.3nClossk (“real”, scaled, see slide 4)

Page 7: Power Losses due to  Button and Reentrant BPMs

gap=8.5 mm

Reentrant BPM

Page 8: Power Losses due to  Button and Reentrant BPMs

Gaussian bunch with sigma=25 mkm

Loss (analytical) = 2.77 kV/nC

Loss (ECHO) = 2.68 kV/nC

Reentrant BPM

02.5

1Loss

44

Z c g

a

g=8.5 mm, a=39 mm

-5 0 5 10

-5

0

5

z [cm]

r [cm]

Page 9: Power Losses due to  Button and Reentrant BPMs

Long range wake

Up to 3 m for sigma =2.5 mm

22

2

0

( ) 2 cos 2

ii

fsNc c

i ii

sW s k f e

c

22

2

0

2

ifNc

ii

Loss k e

Reentrant BPM

Prony-Pisarenko fit

P. Thoma, Berechnung der Güten einiger Resonanzen eines verlustfreien Resonators mit angekoppeltem verlustfreien Wellenleiter.(1992, Darmstadt, Diplomarbeit betreut bei Martin Dohlus)

Page 10: Power Losses due to  Button and Reentrant BPMs

Long range wake

0 20 40 60 80 100

-0.3

-0.2

-0.1

0

0.1

0.2

2 4 6 8 10 12 14 16

x 109

0

1

2

3

4

5

x 1010

Freq, GHz 2*K_n, kV/nC alpha Q

1 1.22 0.105 0 Inf

2 3.81 0.099 0.22 5.3634

3 5.91 0.071 0.08 24.3639

4 8.1 0.052 0.17 14.8516

5 13.2 0.012 0.1 42.3142

ii

i

fQ

Loss for sigma = 25mkm (ECHO) = 2.68 kV/nC

f [Hz]

k [kV/C]W [kV/nC]

s [cm]

224

2

0

kV(5) 2

nC

if

ci

i

Loss k e

0.332.4048 2.94GH2cutoff

cf z

a

wake Modal loss factor

-5 0 5 10

-5

0

5

Page 11: Power Losses due to  Button and Reentrant BPMs

Button BPM vs. Reentrant BPM

for sigma = 25mkm

3250 [ ]bN bunches30 [ ]repf Hz

1[ ]q nC

Loss factor,

kV/nC

Power loss,

Watt

Button BPM 0.3 0.03

Button BPM

(optimized for signal)

0.8 0.08

Reentrant BPM 2.7 0.26

Page 12: Power Losses due to  Button and Reentrant BPMs

BPM vs. othersfor sigma = 25mkm 3250 [ ]bN bunches 30 [ ]repf Hz 1[ ]q nC

Loss factor,

kV/nC

Power loss,

Watt

Button BPM

(optimized for signal)

0.8 0.08

Reentrant BPM 2.7 0.26

10 flange gaps (0.6 mm) 0.66*10=6.6 0.64

TESLA Cryomodule

(including belows)

148 14.4

superconductive normal conductivity

Page 13: Power Losses due to  Button and Reentrant BPMs

Acknowledgements

- to Martin Dohlus for useful discussions

- to Rolf Schuhmann for “Prony-Pisarenko” Matlab script

- to CST GmbH for the new wakefield solver