Point-of-Care Overview Gliwice November 17 th , 2008

Point-of-Care Overview Gliwice November 1 7 th , 200 8

Embed Size (px)

DESCRIPTION

Point-of-Care Overview Gliwice November 1 7 th , 200 8. Agenda. POC Basics Connectivity System Components POC Interfaces Device Messaging Layer Observation Reporting Interface. POS Basics. What is POS? - PowerPoint PPT Presentation

Citation preview

Point-of-Care Overview

GliwiceNovember 17th, 2008

POC Basics Connectivity System Components POC Interfaces Device Messaging Layer Observation Reporting Interface

Agenda

What is POS?

• Point-of-Care testing is defined as various testing conducted near the site of patient care.

• It incorporates different environments, including hospital based testing, near-patient testing, physician’s-office testing, and patient self testing.

POS Basics

POC Connectivity

• Allow seamless multi-vendor interoperability and communication between point-of-care devices, data concentrators, and clinical information systems.

• Provide framework for engineers to design devices, workstations and interface for multiple types and brands of POC devices to communicate bi-directionally with access points, data concentrators, and laboratory information systems from variety of vendors.

POS Basics

What is POC Standard?

• The core of the standard is a group of specifications developed by the Connectivity Industry Consortium (CIC).

• Describes the attributes of an access point; the communication protocols between the device and access point; communication between a data manager and clinical information system.

POS Basics

Evolution of POC standards

Cooperative effort of: providers, manufacturers, representatives of:

• CIC• NCCLS• HL7• IEEE• CAP• FDA• JCCLS• IFCC

POS Basics

POC Basics Connectivity System Components POC Interfaces Device Messaging Layer Observation Reporting Interface

Agenda

Point-of-Care Device• Hand-held devices; test modules that are part of the

other instrumentation (patient monitor, for example); or small, bench-top analyzers

Connectivity System Components

Access Point• Allow to communicate with an Observation Reviewer to

report results and exchange information

Connectivity System Components

The Observation Reviewer (POC Data Manager)

• The primary role of an Observation Reviewer is to host one or more services to which point-of-care diagnostic devices connect.

• Services hosted by an Observation Reviewer may exchange data with existing information systems that already exist in the hospital laboratory

Connectivity System Components

The Observation Recipient (LIS, CDR, or EMR)• In many cases, the final resting place of a point-of-care

diagnostic test observation is inside an Observation Recipient system

• Typically, LIS or Clinical Data Repository (CDR) systems fill the role of Observation Recipient

Connectivity System Components

Device Interface• Governs the flow of information between devices and

Observation Reviewers

Observation Reporting Interface (EDI interface)

• Describes messaging between Observation Reviewers and Observation Recipients

Connectivity System Components

POC Basics Connectivity System Components POC Interfaces Device Messaging Layer Observation Reporting Interface

Agenda

DML• Device Messaging Layer specification describes the dialog

between a device and Observation Reviewer

POS Interfaces

The DML allows bidirectional data exchange concerning the following topics:I.Device Status

II.Observations

1. Patient Tests

2. Calibration Tests

3. Quality Tests

i. Liquid QC

ii. Electronic QC

iii. Calibration Verification

iv. Proficiency Test

III.Device Events

IV.Update Lists

1. Operator List

2. Patient List

V.Directives

1. Basic (e.g., Lockout, Goto Standby)

2. Complex (e.g., Set Time)

3. Vendor-specific

VI.Vendor-specific Data

POS Interfaces

DAP• Device Access Point specification defines a law cost, flexible

means to reliably communicate messages between POC Device and Observation Reviewer

POS Interfaces

DAP and DML interfaces are layered on top one another in the OSI model

POS Interfaces

DML

DAP

• Observation Reporting Interface – facilities the communication of test results and orders information between Observation Reviewers and Observation Recipients

• The interface provides bidirectional flow between these services

POS Interfaces

POC Basics Connectivity System Components POC Interfaces Device Messaging Layer Observation Reporting Interface

Agenda

Message Flow•In general, the communication between the Device and Observation Reviewer can be described at a high – level in terms of dialog between two actors•Example: Scheme of base profile message flow

Device Messaging Layer

Message Encoding•POC Device Messaging Layer’s messages leverage the XML encoding rules defined in HL7 version 3•Example: Simple Glucose Messages

Device Messaging Layer

Message Encoding

Device Messaging Layer

POC Basics Connectivity System Components POC Interfaces Device Messaging Layer Observation Reporting Interface

Agenda

• EDI employs existing HL7 messages, segments, and fields in order to communicate test results and ordering information

• Four new triggers (as compared to HL7 v2.4) are defined for HL7 ORU message

• As long as the final implementation uses the messages and fields defined in POCT1 specification (ORU^R30, ORU^R31, ORU^R32, ACK^R33), the resulting interface is compliant with the POCT1 Observation Reporting Interface specification

Observation Reporting Interface

• Individual institutions or deployments may have additional requirements beyond addressed by POCT1 specification

• Message fields not defined for use by POCT1 specification may be used to support these site-specific requirements

Observation Reporting Interface

Message Example• Sample message exchange, preordered test with single-

valued result• ORU^32 – Observation result message from POCT1DMS-

OBSREV to POCT1LIS-OBSRCPT sent 6/10/00 1:03:55

Observation Reporting Interface

ORU^30Unordered Observation – Place Order

• One example of this use case occurs when a doctor verbally instructs a nurse to perform a test

• To allow the Observation Reviewers correlate every result with its associated order, the Observation Recipient will return the newly created Order ID in the application-level acknowledgement to this ORU^30 message

Observation Reporting Interface

ORU^31New Observation – Search for an Order

• In this case, the Observation Reviewers does not know if an order has been placed

• This trigger instructs the Observation Recipient to search for an existing order for the associated results

Observation Reporting Interface

ORU^32Preordered Observation

• In this case order information is provided by either of the following schemes:

The user enters an accession number at the POC Device when performing test

If the Device doesn’t support that input capability or the accession number isn’t known at the point-of-care, the Observation Reviewer (e.g., POC Data Manager) retrospectively determines the appropriate order to match to the test result

Observation Reporting Interface