Published by LM 0466 Service PaCE Printed in The Netherlands Subject to modification EN 3122 785 14581 © Copyright 2004 Philips Consumer Electronics B.V. Eindhoven, The Netherlands. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permission of Philips. Colour Television Chassis FM23, FM24, FM33 AA Supplement ALIS PDP Repair Manual Contents Page 1 Technical Specifications, Connection, and Chassis Overview 2 2 Safety Instructions, Warnings, and Notes 3 3 Directions for Use (Not Applicable) 4 4 Mechanical Instructions 4 5 Service Modes, Error Codes, and Faultfinding 9 6 Block Diagrams, Testpoint Overview, and Waveforms 31 (Not Applicable) 7 Circuit Diagrams and PWB layouts 33 (Not Applicable) 8 Alignments 33 9 Circuit Descriptions 34 List of Abbreviations 35 10 Spare Parts List (Not Applicable) 36 11 Revision List 36

Philips Fm23 Fm24 Fm33 AA

Embed Size (px)

Citation preview

Page 1: Philips Fm23 Fm24 Fm33 AA

Colour Television Chassis

Published by LM 0466 Service PaCE

©Copyright 2004 Philips Consumer EAll rights reserved. No part of this puretrieval system or transmitted, in anymechanical, photocopying, or otherw

FM23, FM24, FM33AA

Supplement ALIS PDP Repair Manual

Contents Page1 Technical Specifications, Connection,

and Chassis Overview 22 Safety Instructions, Warnings, and Notes 33 Directions for Use (Not Applicable) 44 Mechanical Instructions 45 Service Modes, Error Codes, and Faultfinding 96 Block Diagrams, Testpoint Overview, and

Waveforms 31(Not Applicable)

7 Circuit Diagrams and PWB layouts 33(Not Applicable)

8 Alignments 339 Circuit Descriptions 34

List of Abbreviations 3510 Spare Parts List (Not Applicable) 3611 Revision List 36

Printed in The Netherlands Subject to modification EN 3122 785 14581

lectronics B.V. Eindhoven, The Netherlands.blication may be reproduced, stored in a form or by any means, electronic,

ise without the prior permission of Philips.

Page 2: Philips Fm23 Fm24 Fm33 AA

Technical SpecificationsEN 2 ALIS-PDP Suppl.1.

1. Technical Specifications

1.1 Chassis overview

Figure 1-1

E_14580_001.eps310304

ABUSL BOARD ABUSR BOARD

ADM1 ADM2 ADM3 ADM4 ADM5 ADM6 ADM7 ADM8

XBB

ADRESS MODULE (ADM)

Y-SUS BOARD

LOGIC BOARD

PSU BOARD

X-SUS BOARD

SCAN MODULE

Page 3: Philips Fm23 Fm24 Fm33 AA

Safety Instructions, Warnings and Notes EN 3ALIS-PDP Suppl. 2.

2. Safety Instructions, Warnings and Notes

2.1 Safety instructions

It is not allowed to operate the FTV-set without glass plate. One function of this glass plate is to absorb Infrared Radiation. Without this glass plate the level of Infrared Radiation produced by the plasma display could damage your eyes.1. Safety regulations require that during a repair:

– the set should be connected to the mains via an isolating transformer ( in this particular case a transformer of ≥ 800 VA);

– safety components, indicated by the symbol , should be replaced by components identical to the original ones;

2. Safety regulations require that after a repair the set must be returned in its original condition. In particular attention should be paid to the following points.– Note: The wire trees should be routed correctly and

fixed with the mounted cable clamps.– The insulation of the mains lead should be checked for

external damage.– The electrical DC resistance between the mains plug

and the secondary side should be checked (only for sets that have a mains isolated power supply). This check can be done as follows:• unplug the mains cord and connect a wire between

the two pins of the mains plug;• set the mains switch to the on position (keep the

mains cord unplugged!);• measure the resistance value between the pins of

the mains plug and the metal shielding of the tuner or the aerial connection on the set. The reading should be between 4.5 MΩ and 12 MΩ;

• switch off the TV and remove the wire between the two pins of the mains plug.

– The cabinet should be checked for defects to avoid touching of any inner parts by the customer.

2.2 Warnings

1. ESD All ICs and many other semiconductors are susceptible to electrostatic discharges (ESD ). Careless handling during repair can reduce life drastically. When repairing, make sure that you are connected with the same potential as the mass of the set by a wristband with resistance. Keep components and tools also at this same potential. 1. Available ESD protection equipment:

– complete kit ESD3 (combining all 6 prior products - small table mat) 4822 310 10671

– wristband tester 4822 344 139992. Never replace modules or other components while the unit

is switched on.3. When making settings, use plastic rather than metal tools.

This will prevent any short circuits and the danger of a circuit becoming unstable.

2.3 Notes

1. A glass plate is positioned before the plasma display. This glass plate can be cleaned with a slightly humid cloth. If due to circumstances there is some dirt between the glass plate and the plasma display panel it is recommended to do some maintenance by a qualified service employee only.

2. Never disconnect the power display cable when the set is operating

3. With DST no failures (error-codes) can be red, when the set is in Service-mode.

4. If DST reacts with "error 2", there is no communication between set and DST. Note that IR-transmitter LED is

positioned at right side of IR-receiver eye of the E-box. Take into account that receiver-LED on DST is positioned not in the middle but at the left side. Point corresponding LED"s to each other. In case the amount of Infrared produced by the screen pollutes the communication, the set can be set in Standby-mode. Then still the error-messages can be retrieved.

2.3.1 Notes on safe handling of the plasma display

Notes to follow during service• The work procedures shown with the Note indication are

important for ensuring the safety of the product and the servicing work. Be sure to follow these instructions.

• Before starting the work, secure a sufficient working space.• At all times other than when adjusting and checking the

product, be sure to turn OFF the main POWER switch and disconnect the power cable from the power source of the display (jig or the display itself) during servicing.

• To prevent electric shock and breakage of PC board, start the servicing work at least 30 seconds after the main power bas been turned off. Especially when installing and removing the power supply PC board and the SUS PC board in which high voltages are applied, start servicing at least 2 minutes after the main power bas been turned off.

• While the main power is on, do not touch any parts or circuits other than the ones specified. The high voltage power supply block within the PDP module has a floating ground. If any connection other than the one specified is made between the measuring equipment and the high voltage power supply block, it can result in electric shock or activation of the leakage-detection circuit breaker.

• When installing the PDP module in, and removing it from the packing carton, be sure to have at least two persons perform the work white being careful to ensure that the flexible printed-circuit cable of the PDP module does not get caught by the packing carton.

• When the surface of the panel comes into contact with the cushioning materials, be sure to confirm that there is no foreign matter on top of the cushioning materials before the surface of the panel comes into contact with the cushioning materials. Failure to observe this precaution may result in, the surface of the panel being scratched by foreign matter.

• When handling the circuit PC board, be sure to remove static electricity from your body before handling the circuit PC board.

• Be sure to handle the circuit PC board by holding the large parts as the heat sink or transformer. Failure to observe this precaution may result in the occurrence of an abnormality in the soldered areas.

• Do not stack the circuit PC boards. Failure to observe this precaution may result in problems resulting from scratches on the parts, the deformation of parts, and short-circuits due to residual electric charge.

• Routing of the wires and fixing them in position must be done in accordance with the original routing and fixing configuration when servicing is completed. All the wires are routed far away from the areas that become hot (such as the heat sink). These wires are fixed in position with the wire clamps so that the wires do not move, thereby ensuring that they are not damaged and their materials do not deteriorate over long periods of time. Therefore, route the cables and fix the cables to the original position and states using the wire clamps.

• Perform a safety check when servicing is completed. Verify that the peripherals of the serviced points have not undergone any deterioration during servicing. Also verify that the screws, parts and cables removed for servicing purposes have all been returned to their proper locations in accordance with the original setup

Page 4: Philips Fm23 Fm24 Fm33 AA

Directions for UseEN 4 ALIS-PDP Suppl.3.

3. Directions for Use

Not Applicable

4. Mechanical Instructions

Index of this chapter:• Service Positions Monitor• Rear Cover Removal• Service Position Panels• PDP and Glass Plate Replacement• Re-assembly Note: Figures below can deviate from the actual situation, due to different set executions.

4.1 Service Positions Monitor

4.1.1 Transport Cushions

Figure 4-1 Transport cushions

First, put the monitor in its service position. Therefore, disconnect all cables connected to the monitor and take the monitor of the wall (or tabletop stand). Then, place the monitor in the re-enforced transport cushions that function also as service stand (you can order them separately under code 3122 126 40612). See figure "Transport cushions". Notes:• There are no special "re-enforced service stands". The

cushions used in the factory packaging are already made of reinforced material.

• Always keep in mind that the stands are only designed to keep the monitor in service position as long as the monitor is being serviced. The stands are NOT designed to keep the monitor in the upright position for more then two days.

• After the monitor is serviced, or when nobody is working on the monitor (e.g. in the weekend), it should be removed from the stands and laid down on a cushion or other support system to prevent it from falling.

• Worn out stands should be replaced by new ones (monitor will tilt to much forward).

• Never leave the monitor alone when the stands are not fully pressed on its place.

• It is possible to move the right stand a bit to the right so that you can access the IR-LED and ON/OFF switch, but the monitor can then not be left alone because the stands are NOT designed to carry the weight of the monitor in that

position. A better solution to access the IR-LED and/or ON/OFF switch is to make some holes in the stands at the position of the LED and switch. Do not make the holes to big, as this will influence the strength of the stands.

4.1.2 Aluminium Stands

Figure 4-2 Aluminium stands

The aluminium stands (order code 3122 785 90480) can be mounted with the back cover removed or still left on. So, the stand can be used to store products or to do measurements. It is also very suitable to perform duration tests without taking much space, without having the risk of overheating and no risk of products falling. The stands can be mounted and removed quickly and easy with use of the delivered screws that can be tightened and loosened manually without the use of tools. See figure above. Note: Only use the delivered screws to mount the monitor to the stands.

E_14580_028.eps310304

CL 36532051_001.eps040703

Page 5: Philips Fm23 Fm24 Fm33 AA

Mechanical Instructions EN 5ALIS-PDP Suppl. 4.

4.1.3 Foam Bars

Figure 4-3 Foam bars

The foam bars (order code 3122 785 90580) can be used for all types and sizes of FTVs and LCD TVs and can even be used to e.g. exchange a CRT of a normal TV. By laying the plasma or LCD TV flat on the (ESD protective) foam bars, a stable situation is created to perform measurements and alignments. See figure "Foam stand". By first placing a mirror flat on the table under the TV you can easily see if something is happening on the screen. The bars are also handy to replace the screen (PDP or LCD).

4.2 Rear Cover Removal

Figure 4-4 Rear cover removal

To be able to access or measure the panels, remove the rear cover (metal back plate):1. Remove all fixation screws from the back plate, as

indicated in figure above (the amount of screws that need to be removed differs from the amount in the figure above).

2. Remove the metal back plate. Make sure that wires and flat foils are not damaged during plate removal.

Warning: make sure that the mains power is disconnected when you remove the metal back plate.

4.3 PDP and Glass Plate Replacement

Figure 4-5 Exchanging the glass plate

Exchanging the glass plate1. Take the monitor from its service stand, and put it (face

down) on a soft surface (blanket, foam cushion or foam stand), to make sure that you do not damage the front glass plate.

2. Remove the metal back plate as described in paragraph 'Rear Cover Removal'.

3. Unscrew all fixation screws of the plastic back cover. 4. Lift and remove the plastic back cover. 5. If the triangular shaped cable holder at the left bottom is

present, unscrew the fixation screws of the holder at the left bottom, see figure 'Exchange Glass Plate'.

6. Unplug the cable of the LED/Switch panel, connector 03207. If the ESM Filter Panel at the left bottom is present,

unscrew the fixation screws.8. Unscrew all fixation screws of the (metallised) shielding

frame, see figure 'Exchange Glass Plate'.9. You can now remove the (metallised) shielding frame,

together with the PDP, Audio panel, Power supply and SCAVIO panel attached to it, see figure 'Exchange Glass Plate'. Note: To prevent scratches, make sure to put the shielding frame together with the PDP on a soft surface.

10. Replace the glass plate.

CL 36532051_002.eps190603

CL 16532099_041.eps250901

CL 16532099_046.eps270901

Shielding frame

Front displayFoam cushion

Page 6: Philips Fm23 Fm24 Fm33 AA

Mechanical InstructionsEN 6 ALIS-PDP Suppl.4.

Figure 4-6 Exchanging the PDP

To exchange the PDP panel:1. Take out the SCAVIO panel and Power Supply panel, as

described earlier. 2. Unscrew all fixation screws of the (metallised) shielding

frame (two at the top and two at the bottom, see figure 'Exchange PDP').

3. The shielding frame can now be taken off the PDP. 4. Replace the PDP.

CL 16532099_047.eps260901

Page 7: Philips Fm23 Fm24 Fm33 AA

Mechanical Instructions EN 7ALIS-PDP Suppl. 4.

4.4 Board swap instructions for ALIS PDP

Figure 4-7 Exploded view

Before dismounting panels read notes below!

Caution when removing circuit board!When removing the circuit board after the main power is turned on/off, wait for at least one minute before starting to remove the circuit board.If the circuit board removal is started immediately after turning off the main power, it can result in electric shock or damage to the circuit due to residual electric charge.

On handling the FPC connector!To release the lock, release it by gently flipping it with the nail of the thumb or forefinger. Never pinch the lock lever with fingers or hook on it (especially with a fingernail).Doing so might damage the lock lever.

Figure 4-8 Handling FPC connector

4.4.1 X-SUS Circuit Board Removal / installation Procedure

Remove the circuit board following the steps below. To install the circuit board, reverse the removal procedure.1. Remove the fixing screws (M3 X 8) at 9 locations.2. Release the lock of the FPC connecter (CN21) and

disconnect the signal cable.3. Disconnect the cables from the VH connectors (CN22,

CN23).4. Pull out the XSUS board horizontally and disconnect the

connectors (CN24, CN25).5. Remove the X-SUS board.Make sure that you do not touch the heat sink when removing the Y-SUS board.

4.4.2 Y-SUS Circuit Board Removal / installation Procedure

Remove the circuit board by following the steps below. To install the circuit board, reverse the removal procedure.1. Remove the fixing screws (M3 X 8) at 9 locations.2. Release the lock of the FPC connecter (CN3 1) and

disconnect the signal cable.3. Disconnect the cables from the VH connections (CN32,

CN33).4. Pull out the YSUS board horizontally and disconnect the

connections (CN34, CN35).5. Remove the Y-SUS board

E_14580_002.eps250304

MAINS

AUDIO IN

RS323DVI-D DVI-DVGA2 VGA1

VGA1 VGA2 RC-OUT

L

R

Y/C SSVHS

AUDIOIN

AUDIOIN

AUDIOIN

AV2 AV1

AV3

H

v

CVBSB/Pb/Cb

B/Pr/Cr

L

R

L

R

! All Functional blocks shaded grey are required forthe "Basic Configuration".The remainder is required for the "Enhanced Configuration".

18

19

20

21

25

Red

IR lightsensor

17

16

15

14

13

11

9

10

8

7

6

1

32

12

22

24

23

45

E_14580_025.eps260304

Page 8: Philips Fm23 Fm24 Fm33 AA

Mechanical InstructionsEN 8 ALIS-PDP Suppl.4.

4.4.3 ABUS-L Circuit Board Removal / Installation Procedure

Remove the circuit board by following the steps below. To install the circuit board, reverse the removal procedure.1. Disconnect the connecter CN52 from the ABUS-L board.2. Raise the lock of the FPC connectors CN53, CN54, CN55

and CN56 to release it and remove the ADM flexible board.3. Release the lock of the FPC connecter CN51 and

disconnect the signal cable (FPC).4. Remove the screws (M3X8) fixing the ADM at the 8

locations.5. Remove the screws (M3x8) fixing the ABUS-L board at the

3 locations.6. Remove the ABUS-L board.7. When installing the ABUS L-board, put the ABUS L-board

in such position that it is locked by the tabs before fixing it in position (at 3 locations).

4.4.4 ABUS-R Circuit Board Removal / Installation Procedure

Remove the circuit board by following the steps below. To install the circuit board, reverse the removal procedure.1. Disconnect the connecter CN42 on the ABUS-R board.2. Raise the lock of the FPC connectors CN43, CN44, CN45,

CN46 to release it and disconnect the ADM flexible board.3. Release the lock of the FPC connecter CN41 and

disconnect the signal cable (FPC).4. Remove the screws (M3X8) fixing the ADM at the 8

locations.5. Remove the screws (M3X8) fixing the ABUS-R board at the

3 locations.6. Remove the ABUS-R board.7. When installing the ABUS-R board, put the ABUS R-board

in such position that it is locked by the tabs before fixing it in position (at 3 locations).

4.4.5 LOGIC Board Removal / Installation Procedure

Remove the circuit board by following the steps below. To install the circuit board, reverse the removal procedure.1. Disconnect the EH connecter CN6.2. Release the lock of the FPC connectors CN2, CN3, CN4,

CN5 and disconnect the signal cable (FPC).3. Slide the lock of the FPC connecter CN7 toward the PSU

board side, then press it down toward the front and remove the PSU signal cable.

4. Remove the screws (M3 X 8) fixing the LOGIC board in position at 2 locations.

5. Remove the LOGIC board.6. When installing the LOGIC board, put the LOGIC board in

such position that it is locked by the tabs before fixing it in position (at 3 locations.

4.4.6 PSU Board Removal / Installation Procedure

Remove the circuit board by following the steps below. To install the circuit board, reverse the removal procedure.1. Release the lock of the cable clamp (large).(At 4 locations)2. Disconnect the X-SUS board connecter CN23.3. Disconnect the Y-SUS board connecter CN33.4. Disconnect the ABUSR board connecter CN42.5. Disconnect the ABUSL board connecter CN52.6. Remove the wires (4), (5) from the cable clamp (small).7. Disconnect the LOGIC board connecter CN6.8. Disconnect the PSU signal cable from the PSU board

connecter CN69 side.

Page 9: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 9ALIS-PDP Suppl. 5.

5. Repair Process and Fault Finding

Index of this chapter:1. Process flow2. Repair instructions3. Faultfinding

5.1 Process flow

The selected workshop receives the defect TV set and investigates the PDP. Two possible solutions shall follow:

5.1.1 Advanced PDP exchange (actual way-of-working)

If the defect concerns one of the folowing items, the actual way of working has to be followed:• Glass broken• Flex foil damaged• Y-COM IC on flex foil is damaged• NVM on logic board defect, no communication with

ComPair

A new PDP will be ordered at Euroservice. Euroservice issues an RMA number and ships a refurbished PDP from its swap

pool in a flight case to the workshop. After receipt the workshop sends the defect PDP, accompanied by a completely filled in Failure Description Form (see Figure 5.1), in this flight case to Euroservice. Euroservice makes sure the defect PDP is repaired and afterwards added to its swap pool. The workshop makes the TV set complete by building in the refurbished PDP. Afterwards the TV set is sent back to the customer.

5.1.2 Customized repair

If the defect is not related to the exceptions, mentioned in 5.1.1, the workshop orders the necessary spare parts, being boards, at Euroservice. After receipt the workshop swaps the concerning board and makes the TV set complete by building in the PDP. Afterwards the TV set is sent back to the customer.

Figure 5-1 PDP flow chart

end user contacts dealer because hisplasma TV set is defect

VIP workshop brings home visit to end userand swaps defect TV set with a loan set

PDP flow chart(from 1st May 2003 onwards)

YES

dealer requests VIP workshopto contact end user

VIP workshop analyses the PDPof the defect plasma TV set

VIP workshop orders refurbished PDPat Euroservice

Euroservice ships refurbished PDP from itsswap pool to VIP workshop in a flight case

VIP workshop swaps PDP'sand makes plasma TV set complete

VIP workshop brings plasma TV set toend user and swaps with loan set

PDP:glass repair

orflex cable machine

needed??

VIP workshop orders spare part(s)being boards at Euroservice

NO

Euroservice ships spare part(s) withnext-day-delivery to VIP workshop

VIP workshop repairs PDP on board leveland makes plasma TV set complete

VIP workshop brings plasma TV set toend user and swaps with loan set

E_14580_027.eps250304

Page 10: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 10 ALIS-PDP Suppl.5.

Figure 5-2 Failure description form

Failure Description Form for Defective Plasma Displays for Philips

From: Factory / Service Repair Workshop

Form to be sent together with the defect Plasma Display

Factory/Service Repair Workshop Product Data Please fill in at least the yellow part Part No: Date Serial No, display: MRA No: Serial No, set:

Condition Code | Symptom Code Possible Condition Codes:

1 Constant Additional Failure Description PDP 2 Intermittent 3 After a While 4 In a Hot Environment 5 In a Cold Environment

In case of 32 FTV please fill in service error codes of the monitor Possible Symptoms:

310 No Picture 35X Other Unstable Picture Problem A Inactive Row(s) 321 Picture Too Dark 381 Burn-In Mark On Display (Phosphor) B Inactive Column(s) 327 Only Partial Picture 382 Scratch On Display C Various Missing Display Cells 350 Unstable Picture 384 Phosphor/Pixel Missing D Picture, but non linear greyscale 351 Synchronisation Poblem a Non Lightning (Flickering) Cells each Color E Video Stretched Over Total Height 352 Picture Luminance Pumping [slow] R:. G:. B:. 431 Missing Color 353 Picture Jitter b Wrong Phosphor/ For Each Color 64X Mechanical noise (accoustical sound) 354 Picture Shaking c Non Extinguishing (Flickering) Cell:. F Broken Plasma Panel 355 Flickering Picture (Luminance) [fast] d High Intensity Cell Defect G Broken flexible cabling 356 Flashing Picture (active-inactive) e Mechanical Failure

35A Frozen Picture - Due To Fujitsu Factory

Signature/Stamp Factory Fujitsu Part of Form (not to be filled in by factory or by Service Workshop) Warranty? no/yes Recognition & Repair Date Conditions (Temp., Soft, ETC ): Ship to FJ? no/yes

Normal Additional Failure Description : Under Stress additional Description Failed Component Serial # defect Serial # replaced Glass Panel X-SUS-Std Y-SUS Logic12 A-Bus Right A-Bus Left DC/DC Other

PCB Name: Repair Part/Location:

Corrective Action: Signature/Stamp Repair Center

Preventive Action:

Signature/Stamp FHP Japan

New symptoms descriptions

E_14580_026.eps250304

Page 11: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 11ALIS-PDP Suppl. 5.

5.2 Repair instructions

5.2.1 General

All below listed Plasma Display Panels must be repaired on board level except in case of:• Broken glass panel• Defective flex foil• Defective Y-COM IC on the flex foilThe Plasma panels with these faults needs to be send back via the central repair procedure of Euroservice. To be able to repair the Plasma Display Panels on board level the following repair tools are available:9965 000 23434 Special LVDS cable

Figure 5-3 Extension cable kit ALIS PDP

3122 785 90581 Foam buffers for PDP

Figure 5-4 Foam buffers for PDP

The following Plasma Display Panels must be repaired on board level:1. 32” H1 ALIS Plasma Display Panel2. 32” H2 ALIS Plasma Display Panel3. 37” H2 ALIS Plasma Display Panel4. 42” H1 ALIS Plasma Display Panel5. 42” H2 ALIS Plasma Display Panel

5.2.2 32” H1 ALIS Plasma Display Panel

These Plasma Display Panels are used in FM23 sets with production code AG00 up to and including AG05. The involved Plasma Display Panels are:

The available modules for the Plasma Display Panel FPF32C106128UA-51 and -52 are:

The available modules for the Plasma Display Panel FPF32C106128UA-62 are:

Remark:1. If the LOGIC board is defective, the procedure mentioned

in chapter 5.x must be used.

5.2.3 32” H2 ALIS Plasma Display Panel

These Plasma Display Panels are used in FM23 sets with production code:• AG07 and higher for the sets 32FD9954/17S and

32FD9954/69S• AG08 and higher for the sets 32FD994/69S• AG09 and higher for the sets 32FD9944/01S The involved Plasma Display Panels are:

The available modules for this Plasma Display Panel are:

Remark:1. If the LOGIC board is defective, the procedure mentioned

in chapter 5.x must be used.

5.2.4 37” H2 ALIS Plasma Display Panel

These Plasma Display Panels are used in FM33 sets with production code AG00 and onwards. The involved Plasma Display Panels are:

The available modules for these Plasma Display Panels are:

Display type Service code number Production code

FPF32C106128UA-51 9322 172 11682

FPF32C106128UA-52 9322 178 04682

FPF32C106128UA-62 9322 190 61682 From AG06 0242 onwards

E_14580_023.eps050404

Power Supplyothersignals

SDAGNDSCL

864

SDAGNDSCL

SCAVIO Customer's Interface Board

Logic Board

CN7 CN6 CN1

CN1

IIC

IICSCAVIO

Compair

Compair

E_14580_024.eps250304

Module descriptionFactory code number

Service code number

X-SUS board FPF17R-XSS5002 996500017432

Y-SUS board FPF17R-YSS5003 996500017433

Logic board FPF17R-LGC5012 996500017435

A-BUS Right FPF17R-ABR5005 996500017436

A-BUS Left FPF17R-ABL5004 996500017437

Signal Cable (Logic - ABUS,SUS) FPF17R-CBL2001 996500017438

Signal Cable (XSUS-YSUS) FPF17R-CBL1001 996500017439

Module descriptionFactory code number

Service code number

X-SUS board FPF17R-XSS5010 996500017440

Y-SUS board FPF17R-YSS5011 996500017441

Logic board FPF17R-LGC5013 996500017442 *1

A-BUS Right FPF17R-ABR5005 996500017436

A-BUS Left FPF17R-ABL5004 996500017437

Signal Cable (Logic - ABUS,SUS) FPF17R-CBL2001 996500017438

Signal Cable (XSUS-YSUS) FPF17R-CBL1001 996500017439

Display type Service code number Production code

FPF32C106128UA-72 9322 194 11682

Module descriptionFactory code number

Service code number

X-SUS board FPF17R-XSS5016 9965 000 22709

Y-SUS board FPF17R-YSS5017 9965 000 22710

Logic board FPF17R-LGC5018 9965 000 22711 *1

A-BUS Right FPF17R-ABR5015 9965 000 22713

A-BUS Left FPF17R-ABL5014 9965 000 22712

Signal Cable (Logic - ABUS,SUS) FPF17R-CBL2001 9965 000 17438

Signal Cable (XSUS-YSUS) FPF17R-CBL1001 9965 000 17439

Display type Service code number Production code

FPF37C128128UA-72 9322 156 44682

Module descriptionFactory code number

Service code number

X-SUS board FPF18R-XSS5007 996500023342

Y-SUS board FPF18R-YSS5008 996500023343

Logic board FPF18R-LGC5009 996500023344 *1

A-BUS Right FPF18R-ABL5005 996500023346

A-BUS Left FPF18R-ABR5004 996500023347

Signal Cable (Logic -ABUS,SUS) FPF18R-CBL100103 996500017431

Signal Cable (XSUS-YSUS) FPF18R-CBL100103 996500017431

Page 12: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 12 ALIS-PDP Suppl.5.

Remark:1. If the LOGIC board is defective, the procedure mentioned

in chapter 5.x must be used.

5.2.5 42” H1 ALIS Plasma Display Panel

These Plasma Display Panels are used in FM24 sets with production code AG00 and higher. The involved Plasma Display Panels are:

The available modules for these Plasma Display Panels are:

Remark:1. If the LOGIC board is defective, the procedure mentioned

in chapter 5.x must be used.

5.2.6 42” H2 ALIS Plasma Display Panel

These Plasma Display Panels are used in FM24 sets with production code:• AG04 and higher for the sets 42FD9934/17S, 42FD9934/

69S, 42FD9944/01S, 42FD9944/17S, 42FD9944/69S and 420P30/00

• AG06 and higher for the sets 42FD9954/69S The involved Plasma Display Panels are:

The available modules for these Plasma Display Panels are:

Remark:1. If the LOGIC board is defective, the procedure mentioned

in chapter 5.x must be used.

Signal Cable (Logic - ABUS,SUS) FPF18R-CBL200112 996500017430

Signal Cable (XSUS-YSUS) FPF18R-CBL200113 996500023345

Display type Service code number Production code

FPF42C128128UB-54 9322 185 78682

Module descriptionFactory code number

Service code number

X-SUS board FPF16R-XSS500203 996500017423

Y-SUS board FPF16R-YSS500303 996500017424

Logic board FPF16R-LGC5006 996500017425 *1

A-BUS Right FPF16R-ABR5005 996500017426

A-BUS Left FPF16R-ABL5004 996500017427

Signal Cable (LOGIC-XSUS) FPF16R-CBL200104 996500017428

Signal Cable (LOGIC-YSUS) FPF16R-CBL200106 996500017429

Signal Cable (LOGIC-ABUS) FPF18R-CBL200112 996500017430

Signal Cable (XSUS-YSUS) FPF18R-CBL100103 996500017431

Display type Service code number Production code

FPF42C128128UB-72 9322 194 10682

Module descriptionFactory code number

Service code number

X-SUS board FPF16R-XSS5008 996500022704

Y-SUS board FPF16R-YSS5009 996500022705

Logic board FPF16R-LGC500703 996500022706 *1

A-BUS Right FPF16R-ABR5011 996500022707

A-BUS Left FPF16R-ABL5010 996500022708

Signal Cable (LOGIC-XSUS) FPF16R-CBL200104 996500017428

Signal Cable (LOGIC-YSUS) FPF16R-CBL200106 996500017429

Signal Cable (LOGIC-ABUS) FPF18R-CBL200112 996500017430

Signal Cable (XSUS-YSUS) FPF18R-CBL100103 996500017431

Module descriptionFactory code number

Service code number

Page 13: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 13ALIS-PDP Suppl. 5.

Figure 5-5

Problem analysis procedure PDP repair / Board swap

The entire Screen does not light.The set is going into protection.

(PSU is OK)

Step 0Check the 3,3V Stby on the PSU and the

Logic board

Step 1Check if there is no short circuit on the Boards

Power Supply lines

Step 3Check current of 5V Vcc Power Supply line, on ABUSL, ABUSR, Y-SUS, X-SUS board.

PDP Repair procedure Board Swap

Vertical Line / Vertical Bar? Horizontal bar?

Step 4Check Va on ABUSL and ABUSR Board

Step 5Check Vs on Y-SUS and X-SUS board

SDM Y-SUS

Step 6Check Vs on Y-SUS and X-SUS board.

X-SUS board XBB

Logic Board Exchangeprocedure.

Use of ComPair

Copy data from thedefective Logic board

Restore data into the newboard

Ship OutAuto alignment procedure

E_14580_008.eps250304

Page 14: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 14 ALIS-PDP Suppl.5.

Figure 5-6

The entire screen does not light

Disconnect CN306 Logic board

Standby LED is on?Set is in Standby?

All the boards are connectedConnect the set to mains.

Disconnect the mains plug.Remove the following power connections

CN23 X-SusCN33 Y-Sus

CN42 ABUSRCN52 ABUSL

Set is going into protection?

3,3V Standby is ok.Switch on the set via RC

N

Switch the set on via vacation switch

Switch vacation switch off

Check 3,3V Stbyon pin 1 CN6Logic board

N

Caution; do never disconnect connectors orremove boards when the mains plug is connected.

Allow discharge of power supplies beforedisconnecting connectors!

Switch vacation switch on and check3,3V Stby on PSU

3,3V Stbyon pin 1 Cn306

is ok?

Defect is on PSUboard.

Standby supply repairSee PSU repair

method

CC on Logic board

YN

Y

Y

Y

Y

1

Check supply voltagesVcc pin 6 Cn306Vs pin 10 Cn323Va pin 1 Cn323

Vcc Pin 3 Cn323Vcc pin 7 Cn342Vcc pin 7 Cn352

N

Replace Logic BoardFollow Logic board

replacement procedure

Problem Analysis Procedure the entire screen does not light.

E_14580_009.eps250304

Page 15: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 15ALIS-PDP Suppl. 5.

Figure 5-7

X-Sus Board CN23VCC pins 3 - 4Vs pins 6 - 8Va pins 1 - 4are shorted?

Check with ohmeter if followingpins are not shorted

Y-Sus Board CN33Vcc pins 1 - 2Vs pins 5 - 7are shorted?

ABUSL BoardVa CN52 pins 1 - 4Vcc CN52 pins 5 -7

are shorted?

X-Sus board is defective

Replace X-Sus board

Remove SDM from the followingconnectors CN34 , CN35

Y-Sus Board CN33Vcc pins 1 - 2Vs pins 5 - 7are shorted?

Y-Sus board is defective.

Replace Y-Sus Board

SDM is defectivePDP is defective

1

N

N

Y

N

Y

Remove ADM from thefollowing connectors

CN53, CN54, CN55, CN56

Y

ADM is defectivePDP is defective

ABUSL Board is defectivePSU board has a short circuit

Replace ABUSL Board

ABUSL BoardVa CN52 pins 1 - 4Vcc CN52 pins 5 -7

are shorted?

N

Y

2

N

Y

End of analysis

Short-circuit check on Power Supply Lines

E_14580_010.eps310304

Page 16: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 16 ALIS-PDP Suppl.5.

Figure 5-8

ABUSR BoardVa CN42 pins 1 - 4Vcc CN42 pins 5 -7

are shorted?

Remove ADM from the following connectorsCN43, CN44, CN45, CN45

Y

ADM is defectivePDP is defective

ABUSR Board is defective.

Replace ABUSR board

ABUSR BoardVa CN42 pins 1 - 4Vcc CN42 pins 5 -7

are shorted?

N

Y

End of analysiis

Only the Logic board CN306 and CN307 areconnected.

Connect set to mainsSwitch vacation switch on

Switch set on via RC

PSU BoardVcc 5V exists a few

seconds?

Logic board isdefective

Replace Logic BoardFollow Logic board replacement

procedure

N

3

N

Check if VCEGOis High

Disconnect the set from AC Mains

Y

In step 3 the 5V Vcc will be checked by use of an external PSU.First adjust the current output on the external PSU to 5V 0,5A

Set V output to 0VConnect external PSU to Diodes D6224 and/or D6225 on the set

PSU (D6224 not present in FM33).See diagram P7

2 Short-circuit check on Power Supply Lines

E_14580_011.eps310304

Page 17: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 17ALIS-PDP Suppl. 5.

Figure 5-9

Set is disconnected from AC mains!Connect CN42 ABUSR

Switch the PSU on

Vcc 5V OK?I < 0,35A?

Switch off the PSUConnect CN52 ABUSL

Switch on the PSU

Vcc 5V OK?I < 0,35A?

Switch off the PSUConnect CN23 X-Sus

Switch on the PSU

Vcc 5V OK?I < 2A?

Switch off the PSUConnect CN33 Y-Sus

Switch on the PSU

Vcc 5V OK?I < 2A?

Switch off the external PSUand disconnect.

Remove ADM 1 - 8

ABUSR board is defective.

Replace ABUSR board

ABUSL board is defective.

Replace ABUSL Board

X-Sus board is defective

Replace X-Sus board

Y-Sus board is defective

Replace Y-Sus board

Switch PSU off

End of analysis

Y

Y

Y

Y

N

N

N

N

3

4

In the next steps the 5V Vcc power supply lines will be checked.AExternal Power Supply is connected to D6224/D6225 5V Vcc on the set PS.For testing each board, ramp up the External PSU from 0 to 5V.Monitor the current!

Logic buffer circuit has abnormalty.

Logic buffer circuit has abnormalty.

DC/DC power supply circuit or controllogic cicuit has abnormality

DC/DC power supply circuit or controllogic cicuit has abnormality

5V Vcc check ABUSR, ABUSL, Y-Sus, X-Sus board

Adjust External PSUmax. current to 2A

E_14580_012.eps250304

Page 18: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 18 ALIS-PDP Suppl.5.

Figure 5-10

4

Connect the set to AC Mains.

PSU board Va 50Vexists?

Disconnect connector CN42 ABUSR board

PSU boardVa 50V exists?

Switch off

Disconnect connector CN52 ABUSL board

switch on

N

N

ADM is defectivePanel chassis is defective

ABUSR board is defective.Replace ABUSR board.

ABUSL board is defective.Replace ABUSL board

Y

Y

PSU boardVa 50V exists Y

Va and Vs Check with internal PSUFor each step switch the set off and on via

the vacation swith and the RC

Switch off

Switch on

Switch on

5

NDisconnect the AC Power.

End of analysis

VA check on the ABUSR and ABUSL board

E_14580_013.eps250304

Page 19: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 19ALIS-PDP Suppl. 5.

Figure 5-11

5

PSU boardVs 80V exists?

Switch off

Disconnect SDM / Y-Sus board

Measure resistance of SDM power lineBetween A1-A2, B1-B2, C1-C2 and D1-D2

SDM Power line isshorted?

SDM is faultyPanel chassis is defective

Switch on

PSU board Vs / Vccis output?

Switch off

Switch offEnd of analysis

N

Y

6

NN

Y

PSU Board Va block is defective.

Switch off

End of analysis

Y

Vs Check on Y-Sus & X-Sus board and SDM / XBB

SDM is faultyPanel chassis is defective

Remark:There is no start up of Vs switched and Va if power supply to

X-Sus (CN23) or Y-Sus (CN33) board is diconnected.

E_14580_014.eps310304

ADM1 ADM2 ADM3 ADM4 ADM5 ADM6 ADM7 ADM8

A2

A1

B1

B2

C1

C2

D1

D2

Page 20: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 20 ALIS-PDP Suppl.5.

Figure 5-12

Disconnect connection fromXBB / X-Sus board

Measure resistance of XBB line.Between A1-B1, B1-A2, A2-B2, B2-A3, A3-B3,

B3-A4, A4-B4

XBB line has short-circuit?

Y-Sus board is defective.Replace Y-Sus board

X-Sus board is defective.replace X-Sus Board

XBB is faultyPanel chassis is defective

X-Sus board is defective

End of analysis

N

Y

6

Vs Check on Y-Sus & X-Sus board and SDM / XBB

There is a posibility to check the VS and Va power supply linesvia an external power supply.External power supply connected to VS or Va power supply lineand ground, output voltage = 20V, current = 0mA or very lowcurrent to charge the capacitors at switch on.

E_14580_015.eps310304

ADM1 ADM2 ADM3 ADM4 ADM5 ADM6 ADM7 ADM8

A1

B1

A2

B2

A3

B3

A4

B4

Page 21: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 21ALIS-PDP Suppl. 5.

Figure 5-13

Vertical line / Vertical bar

Logic - ABUS board signalcable has abnormal

appearance?

ADM flexible hasabnormal appearance?

Switch on

Switch off

One vertical line?

Signal cable is defective.

ADM is defectivePDPs is defective

End of analysis.

Tap lightly on ADM flexibleheat-melted junction

Any changes?Heat-melted junction is

defective.PDP is defective

Panel Adress has open circuit or ADM IC chip is defective.

PDP is defective

End of analysis

N

N

N

1

Y

Y

Y

N

Y

Vertical Line / Vertical bar Problem analysis procedure

E_14580_016.eps250304

Page 22: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 22 ALIS-PDP Suppl.5.

Figure 5-14

Bar of 1/2 screen width on theleft does not light?

Voltage exists atABUSL board CN52?

Switch offDisconnect CN52 from ABUSL board

Switch on

Voltage existsat PSU board?

Logic board isdefective

ABUSL board isdefective

PSU Cable is defective.Connector has poor connection.

Logic board is defective.

1

Y

Y

Y

N

Bar of 1/2 screen width on theright does not light?

Voltage exists atABUSR board CN42?

Switch offDisconnect CN42 from ABUSR board

Switch on

Voltage existsat PSU board?

Logic board isdefective

ABUSR board isdefective

PSU Cable is defective.Connector has poor connection.

Logic board is defective.

Y

Y

N

Y

N

Switch offEnd of analysis

N

N

2

N

E_14580_017.eps250304

Page 23: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 23ALIS-PDP Suppl. 5.

Figure 5-15

Vertical line ofdifferent color?

Exists in left 1/2area?

Switch off.Replace ABUSL board.

Switch on

Normal?

Switch offReplace Logic board

Switch on

Normal?

Normal?

Switch off.Replace Logic ABUSL signal cable.

Switch on

ABUSL board isdefective

LOGIC board isdefective.

Signal cable isdefective

ADM is defectivePDP is defective

Switch offEnd of analysis

Y

Y

N

Y

Y

N

Y

N

3 4

N

N

2

E_14580_018.eps250304

Page 24: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 24 ALIS-PDP Suppl.5.

Figure 5-16

Switch offReplace ABUSR board

Switch on

Normal?

Normal?

Normal?

Switch offReplace Logic board

Switch on

Switch onReplace signal Cables Logic - ABUSR

Switch on

ABUSR board isdefective

Logic board isdefective

Signal cable isdefective

ADM is defective.Panel chassis is

defectiive.

43

Panel is defectivePanel chassis is defective

N

Y

Y

N

N

Y

Switch offEnd of analysis

E_14580_019.eps250304

Page 25: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 25ALIS-PDP Suppl. 5.

Figure 5-17

Horizontal bar

Switch offReplace X-Sus board

Switch on

Switch offReplace X-Sus board (original board)

Replace Y-Sus boardSwitch on

Normal?

Normal?

N

X-Sus board is defective

Y-Sus board is defective

PDP is defectiveSDM or XBB is defective

Switch offEnd of analysis

Y

Y

N

Horizontal bar problem analysis procedure

E_14580_020.eps250304

Page 26: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 26 ALIS-PDP Suppl.5.

Remark: Do not interchange boards between different PDP’s, this can damage your PDP

Figure 5-18

1. Unscrew the SCAVIO panel to be able to reach the cable going to connector CN1 on the Logic Board

2. Disconnect the cable from the SCAVIO panel at connector 0301. Leave the rest connected! Note: In the diagram the cable at 0301 is still connected, but at this moment in the process that should not be.

3. Connect the ComPair I2C cable as given in this diagram.4. Switch on the set. It will go to stand by or protection mode.5. Click the link in ComPair to open the Logic Board exchange

window.6. Click the 'On' button. In the title bar the module type will

appear: 37H1.11, 42H2, or something similar.

7. Click button 'Copy from original'8. The data is read from the EEPROM on the logic board and

displayed in the list.9. Use the 'Save' button to save the information to a file. This

is optional, but better to be safe. Note: If you close the window without saving, all settings will be lost. If you intend to close this window before replacing the board you should save the settings so you can load them later.

10. Click the 'Off' button.11. Switch off the set and replace the Logic Board with another

one.

Logic Board Exchange (1)

1. Copy NVM Data from defective Logic Board

Unscrew the SCAVIO Panel1.

Disconnect the LVDS Cable from the SCAVIO at(CN0310)

2.

Switch on the set4.

Set will go into protection or in stanby5.

Click the link in ComPair to open the Logic Boardexchange window

6.

Click the "On" button.In the titlel bar the module type will appear

7.

Click button "copy from original"8.

Use the "Save" button to save the information to a file9.

Click the "Off" button10.

Switch off the set and replace the Logic board11.

Connect the service Cable (12nc 9965 000 23434) tothe LVDS connector on the FME Logic board

3.

Page 27: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 27ALIS-PDP Suppl. 5.

Figure 5-19

1. Switch off the set and replace the Logic Board with another one. Now also connect the cable to connector 0301 as depicted in the diagram above.

2. Restart the set with the new board. Switch the set on with the remote control and activate CSM (123654). This is to prevent the set to switch off because no input devices are connected.

3. Click the 'On' button.4. The module type will again appear in the title bar. This may

be different now from step 7 because another Logic Board is used. If you closed the window after step 9 and did save the settings you should load them now. Use the Load button to do so.

5. Click button 'Paste to replacement'. The settings copied from the old board previously are now being written to the new board. If successful the button 'Ship out' will be enabled.

6. Click button 'Ship out'.7. Now a process of voltage feedback initialization and self-

adjustment starts. This will take a few seconds. When ready you can switch off the set, disconnect ComPair and restart the set again to test.

8. Exchange the service LVDS cable with the original LVDS cable.

E_14580_022.eps250304

Logic Board Exchange (2)

2. Write NVM Data to the new Logic Board

(1) The PDP screen will be blanked for about 15s,then 15s later, the ’Ship out’ process will end

Switch off the set and replace the Logic boardAnd connect the service cable to the SCAVIO (CN0301)

1.

Switch the set on with the RC and bring the set in CSMusing code 123654

2.

Click the "On" button3.

Load the saved values4.

Click button paste to replacement5.

Click button "Ship Out" (1)6.

When ready you can switch off the set, and disconnectComPair

7.

Exchange back the original LVDS cable to theoriginal with ferrits

8.

Page 28: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 28 ALIS-PDP Suppl.5.

Figure 5-20

No Fault contents Suspected fault location

Analysis procedure and

measure

1

After momentarily going on, the screen becomes black immediately or after a few seconds. Main power is turned off.

X-SUS, Y-SUS PSU Panel chassis LOGIC ABUSL ABUSR

Refer to the entire screen does not light.

2

Screen lights dimly even on the back screen

LOGIC Replace LOGIC board and folow Logic Board echange procedure

3

Single vertical line (of different color)

Panel chassis LOGIC

Refer to vertical Line / bar..

4

Vertical line from the middle of effective scan area (Vertical line of different color)

Panel chassis Replace panel chassis

5

Bar width of 1/7 0f horizontal size or in multiples of 1/7, is displayed. Abnormal display.

Panel chassis ABUSL ABUSR LOGIC Above boards are connected

Refer to vertical Line / bar..

6

Bar width of 3/7 or 4/7 of the screen width, is displayed. Abnornial display. (Vertical line of different color)

Panel chassis ABUSL ABUSR LOGIC Above boards are connected

Refer to vertical Line / bar..

7

Single horizontal line (No light) or single horizontal does not light among the effective scanning area. Single horizontal line does not light

Panel chassis Replace panel chassis

8

Every other line(No light) Entire screen

X-SUS Y-SUS

Replace X-SUS Y-SUS board

Horizontal line

Fault status

Entire screen does not light.

Vertical Line

Vertical bar

E_14580_005.eps260304

Page 29: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault Finding EN 29ALIS-PDP Suppl. 5.

Figure 5-21

E_14580_006.eps260304

No Fault contents Suspected fault location

Analysis procedure and

measure

9

Bar width of 1/8 or multiples of 1/8 of the screen height, is displayed Abnormal (Screen does light)

Panel chassis Replace panel chassis

10

Bar width of 1/2 of the screen height. Abnormal display (Screen does not light)

Panel chassis Y-SUS, X-SUS Above boards are connected

Refer to horizontal bar.

11

Image sticking. Burn in?

Fixed display contents are always displayed.

Panel chassis Perform all white heat run. After judgment, replace panel chassis if needed.

12

Stains Oval-shaped points having abnormal luminance are scattered in the upper or lower part of screen.

Panel chassis Perform all white heat run. After judgment, replace panel chassis.

13

Twinkle The entire screen momentarily becomes brighter or darker.

Poor connector contact. Panel chassis

14

Flicker The entire screen flickers continuously

Poor connector contact. FFC (Flat Foil connector Cable)

Connector / cable reconnection or Cable Exchange

15

Luminance is abnormal

Screen is too dark or too bright. (Out of specifications)

16Chrominance is abnormal

Colors cannot be displayed orrectly.

LOGIC

17Sync is disturbed

LOGIC

Horizontal bar

Replace LOGIC board and folow Logic Board echange procedure

Fault status

burn in?

Page 30: Philips Fm23 Fm24 Fm33 AA

Repair Process and Fault FindingEN 30 ALIS-PDP Suppl.5.

Figure 5-22

E_14580_007.eps260304

No Fault contents Suspected fault location

Analysis procedure and

measure

18Picture distorted

LOGIC

19Steps of gradations are skipped

Luminance linearity is poor.

LOGIC

20Abnormal sound

PSU, X-SUS Y-SUS (Core is broken, or transformer is abnormal)

Locate cause of abnormality from listening and viewing. Replace the cause of problem

21

Control on external communication is abnormal

Contrast, color temperature adjustment and Y cannot be changed.

LOGIC Replace LOGIC board and folow Logic Board echange procedure

Replace LOGIC board and folow Logic Board echange procedure

Fault status

Page 31: Philips Fm23 Fm24 Fm33 AA

Block Diagrams, Testpoint Overview, and Waveforms EN 31ALIS-PDP Suppl. 6.

6. Block Diagrams, Testpoint Overview, and Waveforms

Supplement on FM23, FM24, FM33 (3122 785 13891) service manuals.

Figure 6-1

E_14580_003.eps250304

Page 32: Philips Fm23 Fm24 Fm33 AA

Block Diagrams, Testpoint Overview, and WaveformsEN 32 ALIS-PDP Suppl.6.

Figure 6-2

E_14580_004.eps250304

Page 33: Philips Fm23 Fm24 Fm33 AA

Circuit Diagrams and PWB Layouts EN 33ALIS-PDP Suppl. 7.

7. Circuit Diagrams and PWB Layouts

Supplement on FM23, FM24, FM33 (3122 785 13891) service manuals.

8. Alignments

8.1 Voltage Setting Procedure

The Voltage Setting label, at the top left of the back of the PDP, shows the following messages:

Table 8-1

If the voltage adjustments Vs and Va on the Power Supply Unit, must be performed, depends on the version of Power Supply Unit (see table 2).

Table 8-2

This table also shows if the Vs and Va control loop must be switched ON or OFF.The voltage adjustments Vw and Vx are done automatically via ComPair. After exchange of the Logic Board, click on ship out. The settings from the old Logic Board will be restored in the new Logic Board

Item Adjustment items Measurement point Adjustment value (conditions)

1 Vs voltage adjustment PSU board F241or CN392 test points Voltage setting label indication value* I% (all black)

2 Va voltage adjustment PSU board F240 or CN392 test points Voltage setting label indication value* I% (all black)

3 Vw voltage adjustment X-SUS board connecter CN26 6-pin Voltage setting label indication value* 1% (all black)

4 Vx voltage adjustment X-SUS board connecter CN26 1-pin Voltage setting label indication value* (all black)

PSU version 3 PSU v3 with precision R's PSU version 4

PDP with Vs feedback (-52 PDP) Feedback loop 'OFF', alignment is necessary Feedback loop 'ON', alignment (check) is necessary (see voltage setting label)

Feedback loop 'ON', no alignment necessary

PDP with Vs/Va feedback (with 'B' in serial number)

Feedback loop 'OFF', alignment is necessary Feedback loop 'ON', no alignment (check) necessary

Feedback loop 'ON', no alignment necessary

Page 34: Philips Fm23 Fm24 Fm33 AA

Circuit Descriptions and Abbreviation ListEN 34 ALIS-PDP Suppl.9.

9. Circuit Descriptions and Abbreviation List

9.1 Board Function Description

9.1.1 Logic board Function

Data Processor• ( γ adjustment ( 1 / 2 . 2/ 2 . 4 / 2 . 6 / 2 8)• NTSC/EBU format (Color matrix) Switch• RGB gain Control (White balance adjustment, Amplitude

1imitation)• Error Diffusion Technology (Greyscale adjustment)• Dither (Greyscale adjustment)• Burn-in Pattern generation

Data Converter• Quasi out-line adjustment (luminous Pattern control)

Scan Controller• Address driver control signal generator (ADM) • Scan driver control signal generator (SDM)• X/Y sustain control signal generator

Waveform ROM• Waveform Pattern for drive / Timing memory

MPU• Synchronous détection• System control• Driving voltage (Va, Vs, Vr, Vw) Minute adjustment• Abnormal watch (breakdown detection)/abnormal

processing• Ls (sustain) current control (sustain pulse control)• La (address) current control (sub-field control)• External communication control• Flash memory (firmware)

EEPROM• Control parameter memory • The accumulation energizing time (Every hour)• Abnormal status memory (16 careers)

9.1.2 Function of X-SUS Board

DC/DC power supply block• Vs (+60V) Vw (+185V)/Vx (+45V)• Vcc (+5V) XFvcc (+5V, floating)/XFve (+ 18V,

floating)/Ve (+ 17v)/Vb(-5)

X switching block• Switching during address period• Switching during sustain period• Switching during reset period

Current detector block• Isx (sustain) current detection

9.1.3 Function of Y-SUS Board

DC/DC power supply block• Vcc (+5V) -> Y Fvcc (+5V, floating)/Y Fve (+ 18V, floating)/

Ve (+ 17V)

Switching block• Switching during address period • Switching during sustain period • Switching during reset period

Current detector block• Isy (sustain) current detection • Isp (SDM) current detection

9.1.4 Function of PSU Board

Standby power supply block • AC100-240 +5V & +3V3 Standby

PFC block (AD/DC power supply block) • AC100-240 +390V

AD/DC power supply block • +380V - Vcc (+5V) / Vs (+80V)/Va (+60V)

Current detection block • la (address) current detection

Abnormal voltage monitoring • Vs excess voltage monitoring • Va excess voltage monitoring

Page 35: Philips Fm23 Fm24 Fm33 AA

Circuit Descriptions and Abbreviation List EN 35ALIS-PDP Suppl. 9.

9.2 List of abbreviations

ADM Address moduleBurn-in rack Test equipment of the shelf test in

which the PDP unit is left to stand in drive condition

CPU The unit for controlling the circuit operation

DOXE The control voltage for even-numbered lines in the X direction

DOYSD Used in the drive voltage in the Y direction (down)

DOYSU Used in the drive voltage in the Y direction (up)

DOXO The control voltage for odd-numbered lines in the X direction

External power ON Running the external powers (Vcc, Va, Vs) on the designated voltage. Unless otherwise specified

External power OFF Making the external powers (Vcc, Va, Vs) to stop their operation completely. Unless otherwise specified

Flexible cable The cable to connect the electric circuit to the panel

Flicker Continuous switching between bright and dark views by the PDP itself

Gradation Shading of the display colourOPUMP The name of a circuit where the

current from X/YSUS is returnedOscilloscope A device that allows the flow and

strength of the running current to be visually checked and measured

Panel The indication part of the plasma display panel (PDP)

Panel voltage The voltage required operating the PDP normally

Parts Each PC board and parts mounted in the PC boards

PDP Plasma display panel abbreviatedProbe A cable with contact finger that can

transfer the status of the electric circuit to be measured to an oscilloscope

Protection cover A cover made by aluminium to protect the PDP entirely during test

ROM Memory that stores the drive sequence and other data

SDM Scan moduleSUS XSUS or YSUSTapping Light impactUnit of COM The unit of circuits connected to the

panel with flexible cable. (YCOM UP/DOWN, XBUS UP/DOWN, address sections, the unit of PC boards in ACOM 1 to 5)

Va The power supply at 60 V. which is used to write data on the panel

Vcc The power supply at 5 V, which is used to operate the logic section mainly

Vs The power supply ranging from 127 V to 180 V, which is used to maintain display data. In addition, this can serve as the primary side for the secondary voltage (Vw, -Vy, Vsc)

White solid A condition when the screen display is entirely white

XSUS The name of the circuit that controls the panel operation in the X direction

YCOM The circuit used to output a panel Y line selection signal and the voltage of a display data keep signal

YCOMDV The name of the panel drives voltage signal output from YCOM UP/DOWN section

YSUS The name of the circuit that controls the panel operation in the Y directio

Page 36: Philips Fm23 Fm24 Fm33 AA

Spare Parts ListEN 36 ALIS-PDP Suppl.10.

10. Spare Parts ListFor spare parts list see chapter 5.2

11. Revision ListSupplement on FM23, FM24, FM33 (3122 785 13891) service manuals.

11.1 Service Manual 3122 785 1458.1

The code numbers of X-SUS and Y-SUS boards in table of chapter 5.2.6 are corrected.