TOPC-E4010E-01-07021
PASOLINK NEOPASOLINK NEOINTRODUCTIONINTRODUCTION
Provided for Training / June 2007Provided for Training / June 2007
PASOLINK NEOPASOLINK NEO 11TOPC-E4010E-01-07021
PASOLINK NEOPASOLINK NEO 22TOPC-E4010E-01-07021
PASOLINK PDH FAMILYPASOLINK PDH FAMILY
24.25-27
26GHz
27.5-29.5
28GHz
QPSK10MB (5E1)20MB (10E1)40MB(20E1)80MB(40E1)
100MB(48E1)1 / 2 E3
(2x10/100Base-T)(4x10/100Base-T)
16E1 + DXC
4PSK+RS16QAM+RS32 QAM+RS
PASOLINK NEO
31.8-33.4
32GHz
QPSK10MB (5E1)20MB (10E1)40MB(20E1)80MB(40E1)
(2x10/100Base-T)
4PSK+RS16QAM+RSPASOLINK Mx
16x2MB
51.4-52.637-4021.2-23.617.7-19.714.2-15.3512.75-13.2510.15-11.77.125-8.55.925-7.125INTERFACEMODULATIONSERIES/MODEL
10/11GHz
8x2MB16QAM + RS
1x34MB
PASOLINK+
4x2MB2/4/8/16x2MB
(2x10/100Base-T)
4PSKPASOLINK V4
2x2MB4x2MB8x2MB
16x2MB1x8MB
1x34MB
4PSKPASOLINK V3
52GHz38GHz23GHz18GHz15GHz13GHz7/8GHz6GHzFREQUENCY BAND
PASOLINK NEOPASOLINK NEO 33TOPC-E4010E-01-07021
PASOLINK SDH FAMILYPASOLINK SDH FAMILY
27.5-29.5
28GHz
STM-1(XPIC)
2Port LAN
128QAM+RS
SDH(2xSTM-
1)PASOLINK+
(XPIC)
14.2-15.35
15GHz
STM-12Port LAN
128QAM+RS
SDH(STM-1)
PASOLINK+(Enhanced)
PASOLINK+
37-4031.8-33.4
24.25-27
21.2-23.6
17.7-19.7
12.75-13.25
10.15-11.7
7.125-8.5
5.925-7.125
INTERFACE
MODULATION
SYSTEMSERIES/MODEL
STM-12Port LAN
128QAM+RS
SDH(STM-1)
10/11GHz
STM-1(E)STM-1(O)
(APS)2Port LANGbEther(XPIC)
128QAM+RS
SDH(2XSTM-
1)
STM-12Port LAN
32MLCM +RS
SDH(STM-1)
21x2MB(STM-1)
32QAM+RSSDH(STM-0)
PASOLINK NEO
38GHz32GHz26GHz23GHz18GHz13GHz7/8GHz6 GHzFREQUENCY BAND
PASOLINK NEOPASOLINK NEO 44TOPC-E4010E-01-07021
FEATURESADVANCED TECHNOLOGIES AND SUPERB PERFORMANCE
HIGH SPECTRUM EFFICIENCY / HIGH SYSTEM GAIN
FREQUENCY AGILITY AND EASY TUNING
CONFORMITY WITH ANSI, ITU-R, ITU-T AND ETSI STANDARDS
ELECTRO MAGNETIC COMPATIBILITY (EMC)
SYSTEM FLEXIBILITY
EASY MAINTENANCE FACILITIES
PASOLINK NETWORK MANAGEMENT SYSTEM (PNMSj) (OPTION)
PASOLINK NETWORK MANAGEMENT TERMINAL (PNMTj) (OPTION)
EASY AND QUICK INSTALLATION
TX POWER CONTROL
MULTIPLE SERVICE CHANNELS
PASOLINK NEOPASOLINK NEO 55TOPC-E4010E-01-07021
FEATURES-1
ADVANCED TECHNOLOGIES AND SUPERB PERFORMANCE
MMIC, HIC AND VLSI
Low Power Consumption
10Base-T/100Base-TX, 1000Base-SX, 1000Base-T (LAN Interface)
High reliability and Quality
APS for STM-1 Optical Interface
Excellent field proven MTBF
PDH Cross Connect
Nodal solutions (future) E1 Line Digital Cross Connect
PASOLINK NEOPASOLINK NEO 66TOPC-E4010E-01-07021
FEATURES-2
HIGH SPECTRUM EFFICIENCY / HIGH SYSTEM GAIN
High Spectrum efficiency
High Performance LNA-MIX (Superior receiver sensitivity)
High System Gain achieved by:
QPSK to 128 QAM modulation (S/W selectable)
Forward Error CorrectionBase Band Linearizer
FREQUENCY AGILITY AND EASY TUNING
Field tunable local oscillators (Synthesizer)
RF Point Frequency can be changed through Local Craft Terminal (LCT)
ODU Sub-band changeable by simply replacing the RF Filter.
PASOLINK NEOPASOLINK NEO 77TOPC-E4010E-01-07021
FEATURES-3
CONFORMITY WITH ANSI, ITU-R, ITU-T AND ETSI STANDARDS
Complies with ETS EN301 489-4
ELECTRO MAGNETIC COMPATIBILITY (EMC)
ETSI STANDARDSITU-T STANDARDSITU-R, STANDARDSANSI STANDARDS
EASY AND QUICK INSTALLATION
Very compact and light ( 1+1 IDU only 1 rack unit size)
Only one coaxial cable interconnection Automatic Cable Equalization Different mounting methods for IDU, ODU and Antenna Easy antenna pointing adjustments (RX level monitor point in ODU)
PASOLINK NEOPASOLINK NEO 88TOPC-E4010E-01-07021
FEATURES-4
TX POWER CONTROL
Variable : from 0 up to 30 dB, in 1 dB steps (6-52 GHz) (Depending on the Frequency and Modulation scheme)
Automatic Transmit Power Control (ATPC) or
Manual Transmit Power Control (MTPC)
MULTIPLE SERVICE CHANNELS
Engineering Order Wire (OW) Digital Service Channels - Two RS-232C
Two V.11 (Contra/Co direction selectable)
WS E1 & SC LAN (64/128/256/2048Kbps) (Depend on the INTFC Card used)
NMS Service Channel for PASOLINK Monitoring
In SDH configuration access to E1, F1, DCCr bytes in the STM-1 SOH
PASOLINK NEOPASOLINK NEO 99TOPC-E4010E-01-07021
FEATURES - 5
SYSTEM FLEXIBILITY
Hot Standby/ Space Diversity / Twin Path systems are available with Hitless switch
Common IDU for different RF frequencies (6/7/8/10/11/13/15/18/23/26/28/32/38/52GHz)
Software variable transmission bit rates and modulation
Common ODU for different bit rates (5 to 48E1, 1 to 2 E3, 155Mbps, 2x155Mbps)
Common IDU and ODU for PDH/SDH/LAN including 2xSTM-1 XPIC
(1 + 0 ) unprotected or ( 1+ 1) protected using the same IDU
Wide input line voltage -40.5~57Vdc (optional Power supply Interface +/- (20 ~ 60)Vdc)
(QPSK/16QAM/32QAM/128QAM)
Common IDU and ODU for Repeater with 16E1 DXC interface card
PASOLINK NEOPASOLINK NEO 1010TOPC-E4010E-01-07021
FEATURES - 6
EASY MAINTENANCE FACILITIES
Full front panel access for all cabling and user interfaces
Near End, Far End Base-band Loop back + IF Loop back facilities
OW calling facility between IDU IDU Party Line
Pre-settable BER alarm point: 10-3, 10-4 10-5 or 10-6 (alarm and AIS injection)
Easy Local monitor and maintenance using LCT (USB connection & IE Browser)
Local and Remote monitoring of IDU & ODU operating condition from PNMTj
Network Monitor by PNMSj or PC-MG
PASOLINK NEOPASOLINK NEO 1111TOPC-E4010E-01-07021
FEATURES - 7
PASOLINK NETWORK MANAGEMENT SYSTEM (PNMSj) (OPTION)
User friendly operation
Free from OS limitations, PNMSj runs on both Windows and UNIX
Remote access and control of any PASOLINK Terminal in the network
Link oriented monitor and control ( both sides of a microwave link)
Multi level security
Real Time Event Logging and Event History
ITU-T G.826/G.828 Performance Monitor (Table /graph presentation)
Real-time monitor of Network Elements (NE)
SNMP Interface (Option)
Monitor & Control using Remote Client
Auto Discovery of NEO Network Elements
PASOLINK NEOPASOLINK NEO 1212TOPC-E4010E-01-07021
FEATURES - 8
User friendly operation as maintenance terminal
PASOLINK NETWORK MANAGEMENT TERMINAL (PNMTj) (OPTION)
Link oriented monitor and control for both Local and Remote terminals
Uses Windows XP/2000 with mobile PC
NE Network property setting
Configuration & Program file download/upload
NE Setup and Provisioning
PASOLINK NEOPASOLINK NEO 1313TOPC-E4010E-01-07021
SYSTEM & MODULATIONSYSTEM & MODULATION
SDHSDH
PDHPDH LANLAN
QPSKQPSK 128QAM128QAM
32QAM32QAM16QAM16QAM
PASOLINK NEOPASOLINK NEO 1414TOPC-E4010E-01-07021
TRANSMISSION CAPACITYTRANSMISSION CAPACITY
156Mbps 100Mbps
80Mbps
40Mbps10Mbps
20Mbps
2x156Mbps
PASOLINK NEOPASOLINK NEO 1515TOPC-E4010E-01-07021
TRANSMISSION CONFIGURATIONSTRANSMISSION CONFIGURATIONS
2x(1+0) Repeater
TwinPath
SD(1+0)
(1+1)
2x(1+1)
PASOLINK NEOPASOLINK NEO 1616TOPC-E4010E-01-07021
0 3.5 7.0 14.0 28.0 40.0 56.0 [MHz]Adjacent CH Spacing
Modulation256QAM
128QAM
64QAM
32QAM
16QAM
8PSK
4PSK5E1 10E1 20E1
5E1 10E1 20E1 40E1
100MB/48E1
STM-1XPIC
NEO CAPABILITYNEO CAPABILITY
PASOLINK NEO(Standard version)
PASOLINK NEOPASOLINK NEO 1717TOPC-E4010E-01-07021
NEO CAPABILITY NEO CAPABILITY
16E1
---------------40Mbps(20E1)3
---
---
---
---
---
2PortLAN
------------------40Mbps(16E1)3
---
4PortEther
---
48E1
---
16E1 DXC
GbELX
GbESX
STM-1Opt.S1/L.1
STM-1Elec.
INTF Card Bitrate(Number of E1s)
---
---
---
---
---
---
---
---
5
5
4
2
1
---
---
---
---
---
---
---
---
100MB(48E1)
20Mbps(10E1)
STM-1
80Mbps(40E1)
10Mbps(5E1)
2 port LAN
16E1 +2Port LAN16E1 +2Port LAN with DXC
28(27.5)128QAM
48 X E1 Module4 port LAN
CHANGE MODULE
Gb Ether
STM-1 Module
28(27.5)32QAM28(27.5)14(13.75)73.516QAM
28(27.5)14(13.75)7QPSKChannel Separation (MHz)Modulation Scheme
15510080402010STM-148E140E120E110E15E1Capacity (E1/STM-1)
Transmission capacity (Mbps)
Ethernet
PASOLINK NEOPASOLINK NEO 1818TOPC-E4010E-01-07021
LAN FunctionLAN Function SummarySummary
X
O
1548 bytes
16Mbps (WS)256 Kbps (SC)
PDH (40 ~ 80 M)
2 (RJ-45)
10BASE-T100BASE-TX
E3 INTFC
X
O
1548 bytes
2Mbps (WS/SC)
64/128/256 Kbps (2 Mbps)*
2 (RJ-45)
10BASE-T100BASE-TX
LAN/WS INTFC(SUB SLOT)
O
O
1548 bytes
80Mbps(Main)256Kbps(SC)
PDH(10M80M)
2 (RJ-45)
10BASE-T100BASE-TX
2way ASYNCDXC
XXXX2WAY DXC (Async.)
OOOORMON
9600 bytes1548 bytes1548 bytes1548 bytesMaximum Frame Length
150Mbps(Main)150Mbps(Main)100Mbps(Main)80Mbps(Main)256Kbps(SC)Maximum Throughput
SDH(156M)SDH(156M)PDH(100M)PDH(10M80M)Supported Capacity
1 (SFP or RJ-45)2 (RJ-45)4 (RJ-45)2 (RJ-45)Number of LAN Port
1000BASE-SX1000BASE-T
10BASE-T100BASE-TX
10BASE-T100BASE-TX
10BASE-T100BASE-TXInterface
GbE INTFCLAN/WS INTFC(MAIN SLOT)4P LAN INTFC16E1 INTFCInterface Card
O: Supported X: Not Available
PASOLINK NEOPASOLINK NEO 1919TOPC-E4010E-01-07021
APPLICATIONSAPPLICATIONS
PASOLINK NEOPASOLINK NEO 2020TOPC-E4010E-01-07021
APPLICATIONSAPPLICATIONS
PASOLINK NEOPASOLINK NEO 2121TOPC-E4010E-01-07021
PDH CROSS CONNECT
Max. 80Mbps(40E1)Air Capacity
16E1+LAN
2x8E1(D-Sub)
Dir-AA) Term DXC
D/I for A
DXC
Dir-AA) Term DXC
D/I for A
DXC
DXC
Dir-AB) 2way-Star
Dir-B
D/I for AD/I for B
Dir-A >= Dir-BDXCDXC
Dir-AB) 2way-Star
Dir-B
D/I for AD/I for B
Dir-A >= Dir-BDXC
Dir-AC) 2way-tree
Dir-B
D/I for A
Rep
Dir-A > Dir-BDXC
Dir-AC) 2way-tree
Dir-B
D/I for A
Rep
Dir-A > Dir-BDXC
Dir-AD) 2way-Rep
Dir-B Rep
Dir-A = Dir-BD/I = 0
Dir-AD) 2way-Rep
Dir-B Rep
Dir-A = Dir-BD/I = 0
2 WAY -TREE
2 WAY -REPEATER2 WAY -STAR
TERMINAL - DXC
PASOLINK NEOPASOLINK NEO 2222TOPC-E4010E-01-07021
ETHERNET CONFIGURATION
PASOLINK NEOPASOLINK NEO 2323TOPC-E4010E-01-07021
NETWORK MONITORING SYSTEMNETWORK MONITORING SYSTEM
Upper NMSUpper NMS
RemoteRemoteClientClient
RemoteRemoteClientClient
Server ModeServer ModeRemote TerminalRemote Terminal
Web based Client/Server concept Web based Client/Server concept
In addition to the 15 Remote Clients, one more Remote Terminal can be configured with Server Mode. Server Mode allows network configuration functions.
PNMTj
PNMTj
PNMTj
PASOLINK NEOPASOLINK NEO 2424TOPC-E4010E-01-07021
PASOLINK NEOPASOLINK NEO 2525TOPC-E4010E-01-07021
PASOLINK (1+0) SYSTEMPASOLINK (1+0) SYSTEM
PASOLINK NEO (FRAME)
PASOLINK NEO (1+0) COMMON MODULES
(Blank) (Blank)
(Blank)
PASOLINK NEOPASOLINK NEO 2626TOPC-E4010E-01-07021
PASOLINK (1+0) SYSTEMS PDHPASOLINK (1+0) SYSTEMS PDH
PASOLINK NEO (1+0) WITH PDH 16E1 + 2PORT LAN INTFC
PASOLINK NEO (1+0) PDH WITH 48E1 INTFC
PASOLINK NEO (1+0) PDH WITH E3 + WS and 2Port LAN INTFC
PASOLINK NEO (1+0) PDH WITH 4 Port LAN INTFC + E1
PASOLINK NEOPASOLINK NEO 2727TOPC-E4010E-01-07021
PASOLINK (1+1) SYSTEMS PDHPASOLINK (1+1) SYSTEMS PDH
PASOLINK NEO (1+1) WITH PDH 16E1+2Port LAN INTFC
PASOLINK NEO (1+1) WITH PDH 48E1 INTFC
PASOLINK NEO (1+1) with PDH E3 INTFC + WS and 2Port LAN INTFC
PASOLINK NEO (1+1) PDH WITH 4 Port LAN INTFC + E1
PASOLINK NEOPASOLINK NEO 2828TOPC-E4010E-01-07021
PASOLINK (1+0) SYSTEMS SDHPASOLINK (1+0) SYSTEMS SDH
PASOLINK NEO (1+0) WITH STM-1 (Electrical) INTFC
PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC (APS CONFIGURATION)
PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC AND WS/SC LAN INTFC
PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC
PASOLINK NEOPASOLINK NEO 2929TOPC-E4010E-01-07021
PASOLINK NEO (1+1) SYSTEMS SDHPASOLINK NEO (1+1) SYSTEMS SDH
PASOLINK NEO (1+0) WITH STM-1 (Electrical) INTFC
PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC
PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC with WS/SC LAN
PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC
PASOLINK NEOPASOLINK NEO 3030TOPC-E4010E-01-07021
PASOLINK NEO XPIC CONFIGURATIONPASOLINK NEO XPIC CONFIGURATION
PASOLINK NEO (1+1) WITH 2x STM-1 INTFC with XPIC
PASOLINK NEO (1+0) WITH 2x STM-1 INTFC with XPIC
PASOLINK NEOPASOLINK NEO 3131TOPC-E4010E-01-07021
PASOLINK NEO OTHER CONFIGURATIONSPASOLINK NEO OTHER CONFIGURATIONS
PASOLINK NEO (1+0) WITH DC-DC CONV (PDH & SDH)
PASOLINK NEO (1+0) WITH GbE INTFC with WS/SC LAN (SDH)
PASOLINK NEO (1+1) WITH PDH 16E1+2Port LAN INTFC AND 2 WAY / XC
OPT
PASOLINK NEO (1+0) WITH 2 PORT LAN INTFC (SDH)
M.S
PASOLINK NEOPASOLINK NEO 3232TOPC-E4010E-01-07021
PASOLINK NEO IDU MODULESPASOLINK NEO IDU MODULES
Main SlotSDHGbE INTFC (1000 BASE-SX /1000 BASE-T)H3021 [A]4
Main (2 PORT LAN) / Sub-Slot (WS/SC LAN)SDHLAN / WS INTFCH2965 [C]5
Main Slot (2 Port LAN) SDHLAN / WS INTFCH2965 [C]4
Main SlotSDHGbE INTFC (1000 BASE-LX/1000 BASE-T)H3021 [C]4
Sub-Slot (APS)SDHSTM-1 INTFC Optical (S 1.1)H2960 [B]5
Sub-Slot (APS)SDHSTM-1 INTFC Optical (L 1.1)H2960 [C]5
With 2 Port LANPDH16E1 E/W 2 Way DXC INTFCH2980 [B]6
Sub-Slot (WS/SC LAN)SDHLAN / WS INTFCH2965 [A]5
Sub-Slot (WS)SDHLAN / WS INTFCH2965 [B]5
Main SlotSDHSTM-1 INTFC Optical (L 1.1)H2960 [C]4
Main SlotSDHSTM-1 INTFC Optical (S 1.1)H2960 [B]4
Two E3, up to 8 WSPDHE3 INTFCH30106
With E1sPDH4P LAN INTFCH30206
7
6
6
4
3
3
2
1
NO.
PASOLINK NEO IDU RACK AND MODULES
COMMONCTRLH2950
PDH48E1 INTFCH3000
PDH16E1 INTFC + 2 Port LANH2980 [A]
Main SlotSDHSTM-1 INTFC ElectricalH2960 [A]
(1+0) (with EHG ODU)COMMONDC-DC CONVH3040
(1+1)COMMONMODEMH2940
(1+0)COMMONMODEMH2940
COMMONRACKH2931
REMARKSMODULE NAMECODE NO.
12
3
4 5
7
6
PASOLINK NEOPASOLINK NEO 3333TOPC-E4010E-01-07021
PASOLINK NEO PDH BLOCK DIAGRAMPASOLINK NEO PDH BLOCK DIAGRAM
PASOLINK NEO (1+0) (PDH)
PASOLINK NEO (1+1) (PDH)
*.OPTION
PASOLINK NEOPASOLINK NEO 3434TOPC-E4010E-01-07021
PASOLINK NEO SDH BLOCK DIAGRAM PASOLINK NEO SDH BLOCK DIAGRAM
PASOLINK NEO (1+1) (SDH)
PASOLINK NEO (1+0) (SDH)
*OPTION 1. STM-1 ELECTRICAL OR OPTICAL OR LAN
2. STM-1 OPTICAL ON SUB SLOT FOR APS
3. WS/ LAN AUXILIARY SIGNALS
PASOLINK NEOPASOLINK NEO 3535TOPC-E4010E-01-07021
PASOLINK NEO XPIC (SDH) BLOCK DIAGRAM PASOLINK NEO XPIC (SDH) BLOCK DIAGRAM PASOLINK NEO (1+0) FOR XPIC (SDH)
*OPTION 1. STM-1 ELECTRICAL OR OPTICAL OR LAN
2. STM-1 OPTICAL ON SUB SLOT FOR APS
3. WS/ LAN AUXILIARY SIGNALS
PASOLINK NEOPASOLINK NEO 3636TOPC-E4010E-01-07021
PASOLINK NEO REPEATER BLOCK DIAGRAM PASOLINK NEO REPEATER BLOCK DIAGRAM
PASOLINK NEO TWO WAY XC CONFIGURATION FOR PDH
*OPTION
PASOLINK NEOPASOLINK NEO 3737TOPC-E4010E-01-07021
PASOLINK NEOPASOLINK NEO 3838TOPC-E4010E-01-07021
PERFORMANCE
-98.0100.5103.0105.0107.5107.5108.0107.5106.5112.0112.010MB/16QAM
-95.097.5100.0102.0104.5104.5105.0104.5103.5109.0109.020MB/16QAM
-92.094.597.099.0101.5101.5102.0101.5100.5106.0106.040MB/16QAM
-81.584.086.586.588.088.090.089.589.594.594.5156MB/128 QAM
Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]System Gain
-84.0-87.5-87.5-89.0-89.0-89.589.5-89.5-89.0-89.0-90.0-90.010MB/QPSK
--81.0-84.5-84.5-86.0-86.0-86.5-86.5-86.5-86.0-86.0-87.0-87.020MB/QPSK
-78.0-81.5-81.5-83.0-83.0-83.5-83.5-83.5-83.0-83.0-84.0-84.040MB/QPSK
105.5
102.5
99.5
89.0
87.5
-83.5
-80.5
-77.5
-74.5
-73.0
-67.0
18
14.5
14.5
14.5
38GHz
111.0
108.0
105.0
94.0
92.5
-85.0
-82.0
-79.0
-76.0
-74.5
-68.5
22
18
18
18
28GHz
109.5
106.5
103.5
91.5
90.0
-83.5
-80.5
-77.5
-74.5
-73.0
-67.0
22
17
17
17
32GHz
114.0
111.0
108.0
97.5
95.5
-85.0
-82.0
-79.0
-76.0
-74.5
-68.5
25
21.5
21
21
10-11GHz
119.0
116.0
113.0
103.0
100.5
-86.0
-83.0
-80.0
-77.0
-75.0
-69.5
Measured at ODU RX port (dBm)t at 10-6 BER [BER at 10-3 value below -1.5 dB]
29
27
25
25
Measured at ODU TX port
6-7GHz
119.0
116.0
113.0
103.0
100.5
-86.0
-83.0
-80.0
-77.0
-75.0
-69.5
29
27
25
25
8GHz
--79.0-79.5-79.5-79.5-79.040MB/16QAM
--82.0-82.5-82.5-82.5-82.020MB/16QAM
--85.0-85.5-85.5-85.5-85.010MB/16QAM
-92.594.094.096.095.5100MB/32QAM
-96.098.598.599.098.580MB/16QAM
81.0105.0107.5107.5106.5108.040MB/QPSK
84.0108.0110.5110.5109.5111.020MB/QPSK
87.0111.0113.5113.5112.5114.010MB/QPSK
Receiver Threshold
--68.5-69.0-69.0-69.0-68.5156MB/128 QAM
--74.5-75.0-75.0-75.0-74.5100MB/32QAM
--76.0-76.5-76.5-76.5-76.080MB/16QAM
Transmit Power
-1819192121128QAM
-181919212132QAM
-20222222.522.516QAM
32224242325QPSK
23 GHz 26 GHz13 GHz 52 GHz18 GHz15 GHzITEM
Rx Threshold values given are with the ODU mounted directly to the antenna for (1+0) or (1+1) two antenna configuration.
For (1+1) configuration with one Antenna, the losses in the Hybrid combiner/divider must be considered. Typically about 7dB loss in the link.
6-38 GHz +/- 1.5 dB
6-26GHz +/- 1.5dB28-52GHz +1.5/-2.5 dB
6-38 GHz +/- 1.5 dB
6-38 GHz +/- 1.5 dB
Guaranteed TX Power
6-52 GHz +3 dB
Rx Threshold at 10-6 BER
Guaranteed Threshold
16 QAM: 6-38 GHz -3 dB
QPSK: 6-26GHz -3 dB28-52GHz -4 dB
32QAM: 6-38 GHz -3 dB
128QAM: 6-38 GHz -3 dB
Guaranteed System Gain
PASOLINK NEOPASOLINK NEO 3939TOPC-E4010E-01-07021
PERFORMANCE
TX IF : 340 MHz RS IF: 140 MHz, Control signal : 10 MHz (5 MHz Ref: XPIC only)IFL signals (IDU-ODU)
-48 V DC (-40.5 TO 57 V DC)DC Power
Max RSL and
Residual BER
TX PWRControl
(1 dB Step)
TX PWR(dBm)
FREQUENCY STABILITY
Remote Mount
Direct Mount
RF RX Level 20dBm for the BER less than 10-3 / Residual BER: Less than 10-12 at RSL = -30 dBm128QAM
RF RX Level -15 dBm ( no error) / Residual BER: Less than 10-12 at RSL = -30 dBmQPSK
0 20 dB128QAM
0 23 dB32QAM
14.5
14.5
14.5
18
PBR 320
37-40
38GHz
18
18
18
22
PBR 320
27.5-29.5
28GHz
17
17
17
22
PBR 320
31.8-33.4
32GHz
21
21
21.5
25
PDR 100
10.15-11.7
10-11GHz
RF RX Level 20dBm for the BER less than 10-3 / Residual BER: Less than 10-12 at RSL = -30 dBm
RF RX Level 20dBm for the BER less than 10-3 / Residual BER: Less than 10-12 at RSL = -30 dBm
0 -24 dB
0 30 dB
25
25
27
29
+/- 6 ppm (Guaranteed: +/- 10 ppm)
N-TYPEPDR 70
N/A
5.925-7.125
6GHz
25
25
27
29
N-TYPEPDR 84
N/A
7.125-8.5
7-8GHz
1819192121128QAM
0-10dB0 25 dBQPSK
16QAM
16QAM
32QAM
32224242325QPSK
-20222222.522.516QAM
-181919212132QAM
51.4-52.624.2-2721.2-23.617.7-19.714.2-15.3512.75-13.25
NEC ORIGINAL
PBR 260PBR 220PBR 220PBR 140PBR 120
23 GHz 26 GHz13 GHz 52 GHz18 GHz15 GHz
PASOLINK NEOPASOLINK NEO 4040TOPC-E4010E-01-07021
PERFORMANCE - PDH
ODU Side: N Type female, 50 ohms (Coaxial)IDU Side: TNC Type female, 50 ohms (Coaxial)300 m (in case of 8D-FB cable or equivalent cable)
Inter connecting Connector, Cable Impedance and cable length
482 (W) x 44 (H) x 240 (D) mm: Approx. 4 kgIDU
237(W) x 237 (H) x 101 (D) mm: Approx. 3.5 KG/UNITODUMechanical Dimensions
Modem: 0.5kg, 48E1 INTFC: 0.4kg, 16E1 INTFC: 0.4kg, E3 INTFC: 0.4kg, CTRL: 0.4kgWeight/ Card
UPTO 100MBPSCAPACITY
-48VDC (-40.5 to -57 VDC), Conforms to EN300 132-2Power Requirement
Conforms to EN 60950Safety
Note: 13.75 or 27.5 MHz is applied for 18 GHz / LAN is not available on 48 E1 INTFC
Modem: 10W, 48E1 INTFC: 8W, 16E1 INTFC: 8W, E3 INTFC : 8W, CTRL: 7WIDU Cards
30W (6 to 11 GHz) 23W (13 to 52 GHz)ODU UnitPower Consumption
28 (27.5) MHz32QAM
3.5 MHz, 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz 16QAM
ODU:-33 TO + 50 OC IDU: -5 TO + 50 OCGuaranteed operation
Environmental requirement
N/A128 QAM
IDU, ODU:-40 TO + 70 OCTransportation/storage
ODU:-40 TO + 55 OC IDU: -10 TO + 55 OCWorkable operation
Conforms to EN 301 489-4EMC
ODU: 100% ApplicableIDU: Less than 90% at +50 OC(non-condensing)
Relative humidity
7 MHz, 14 (13.75) MHz, 28 (27.5) MHz QPSK
CH SPACING
D-Sub 37: 16E1/ MDR68: 48E1/ IEC 169-29 (1.0/2.3) E3RJ-45 (2/4 Ports) LAN: 10/100Base-T(X)
INTERFACE
SYSTEM PERFORMANCE (PDH)
PASOLINK NEOPASOLINK NEO 4141TOPC-E4010E-01-07021
PERFORMANCE - SDH
ODU Side: N Type female, 50 ohms (Coaxial)IDU Side: TNC Type female, 50 ohms (Coaxial)300 m (in case of 8D-FB cable or equivalent cable)
Inter connecting Connector, Cable Impedance and cable length
482 (W) x 44 (H) x 240 (D) mm: Approx. 4 kgIDU
237(W) x 237 (H) x 101 (D) mm: Approx. 3.5 KG/UNITODUMechanical Dimensions
Modem: 0.5kg, 48E1 INTFC: 0.3kg, STM-1E INTFC: 0.3kg, LAN/WS INTFC: 0.3kg, CTRL: 0.4kg
Weight/ Card
STM-1: 155 Mbps, (up to 2 x STM-1) LAN : Up to 150 MbpsCAPACITY
-48VDC (-40.5 to -57 VDC), Conforms to EN300 132-2Power Requirement
Conforms to EN 60950Safety
Note: 27.5 MHz IS APPLIED FOR 18 GHz, / 2x 155 Mbps using 2 sets for XPIC / Two STM-1 Optical Interfaces for APS
Modem: 10W, STM-1O INTFC: 8W, 16E1 INTFC: 8W, E3 INTFC : 8W, CTRL: 7WIDU Cards
30W (6 to 11 GHz) 23W (13 to 52 GHz)ODU UnitPower Consumption
N/A32QAM
N/A16QAM
ODU:-33 TO + 50 OC IDU: -5 TO + 50 OCGuaranteed operation
Environmental requirement
28 (27.5) MHz128 QAM
IDU, ODU:-40 TO + 70 OCTransportation/storage
ODU:-40 TO + 55 OC IDU: -10 TO + 55 OCWorkable operation
Conforms to EN 301 489-4EMC
ODU: 100% ApplicableIDU: Less than 90% at +50 OC(non-condensing)
Relative humidity
N/AQPSK
CH SPACING
Optical: LC, Electrical: IEC 169-29 (1.0/2.3) LAN, RJ-45 (2 Ports) : 10/100 Base-T(X) , RJ-45: 1000 Base-T, LC: 1000 Base-SX
Interface
SYSTEM PERFORMANCE (SDH)
PASOLINK NEOPASOLINK NEO 4242TOPC-E4010E-01-07021
CTRL MODULE
MODEM MODULE
PASOLINK NEOPASOLINK NEO 4343TOPC-E4010E-01-07021
CTRL MODULE CTRL MODULE CONNECTORS & SWITCHESCONNECTORS & SWITCHES
BACK TO BACK LAN CONNECTIONCONNECT TO PNMS (ROOT NE)
NMS (RJ-45)
LCT CONNECTION
PNMT CONNECTION
LCT (USB-B)
BACK TO BACK LAN CONNECTION
NE (RJ-45) OW HEAD SET CONNECTION
EOW JACK
OW CALL BUTTON
CALL BUTTON
ON - WHEN REMOVING AND MOUNTING CTRL WITH POWER ON
ON - FOR UP LOADING EQUP CFG FILE TO MEMORY CARD
ON - FOR DOWN LOADING EQUP CFG FROM MEMORY CARD
OFF - FOR NORMAL OPERATION
PROTECT SW
MMC MEMORY CARD SLOT
MMC SLOT
CTRL MODULE IN THE PASOLINK NEO MONITOR THE OPERATING STATUS OF OTHER MODULES IN THE IDU . AND CONTROL THE MODULES ACCORDING TO THE SETUP INFORMATION. IT INTERFACE THE EXTERN ALARMS & CONTROLS, CLUSTER ALARMS, BACK TO BACK CONNECTIONS, NMS CONNECTION AS WELL AS INTERFACING THE LCT AND PNMTj.
CTRL MODULE CONTAIN THE ALL THE MANAGEMENT FUNCTIONS OF THE NE . IT ALSO CONTAINS THE SNMP AGENT, MIB AND SOFTWARE FOR HANDLING ITS OWN ALARMS AND COLLECTING STATISTICAL DATA.
CTRL MODULE STORE THE NETWORK CONFIGURATION & EQUIPMENT CONFIGURATION FILES
PASOLINK NEOPASOLINK NEO 4444TOPC-E4010E-01-07021
CTRL MODULE CTRL MODULE -- INDICATORSINDICATORS
MAINT LED
Slow Blink: Protect SW ON for CTRL Card replacementFast Blink: data transfer to / from Memory CardMAINT MODE ON
MEMORY LED
OFF: Disable access to MMC CardBlinks: Accessing Memory CardON: Enable Access to Memory Card
Modem unit alarmsAny INTFC module alarmCTRL module alarm
Blinks: CPU or Peripheral event occurredIDU Summary Alarm
IDU LED
PASOLINK NEOPASOLINK NEO 4545TOPC-E4010E-01-07021
CTRL MODULECTRL MODULE-- CONNECTORSCONNECTORS
ALM / AUX IN/OUT (High Density D-Sub 44 Pins, Female)
BUZZER INPUT 1
HK3/CLST4 INPUT (+)
HK3/CLST4 INPUT(-)
HK4/CLST3INPUT(+)
HK4/CLST3 INPUT(-)
RL-1 (COM)
RL-2 (COM)
RL-3 (COM)
RL-4 (COM)
RL-5 (COM)
RL-6 (COM)
EOW output 2 (-)
EOW INOUT 2(-)
EOW output 1 (-)
EOW input 1(-)
44
43
42
41
40
39
38
37
36
35
34
33
32
31
RL-3 (NC)23RL-4 (NO)8
RL-4 (NC)22RL-5 (NO)7
RL-5 (NC)21RL-6 (NO)6
RL-6 (NC)20Ground5
19EOW output 2 (+)4
CALL OUTPUT 218EOW input 2 (+)3
BUZZER INPUT 217EOW output 1 (+)2
30HK1 INPUT(+)15
HK5/CLST3 INPUT(+)29HK1 INPUT(-)14
HK5/CLST3 INPUT(-)28HK2 INPUT(+)13
HK6/CLST4 INPUT(+)27HK2 INPUT(-)12
HK6/CLST4 INPUT(-)26RL-1 (NO)11
RL-1 (NC)25RL-2 (NO)10
RL-2 (NC)24RL-3 (NO)9
EOW input 1(+) 16 CALL OUTPUT 11
SC IN/OUT (High Density D-Sub 44 Pins, Female)
NE2 RXD (+)
Ground
Ground
Ground
V.11-1 clock out(-)
V.11-1 clock out(+)
V.11-2 clock in (-)
V.11-2 clock in(+)
V.11-1 clock out(-)
V.11-1 clock out(+)
V.11-1 clock in (-)
V.11-1 clock in(+)
Ground
Ground
NE2 RXD (TERM)
44
43
42
41
40
39
38
37
36
35
34
33
32
31
V.11-2 FP input(-)23V.11-2 Data in(+)8
V.11-2 FP input(+)22V.11-1Data out(-)7
V.11-1 FP output(-)21V.11-1 Data out(+)6
V.11-1 FP output(+)20V.11-1Data in(-)5
V.11-1 FP input(-)19V.11-1 Data in(+)4
V.11-1 FP input(+)18GROUND3
Ground17NE2 TXD(-)2
30RS-232C-2Data in (G)15
RS232C-2 data out(-)29RS-232C-2Data in14
RS232C-2 data out(+)28RS-232C-1Data in (G)13
RS232C-1 data out(-)27RS-232C-1Data in12
RS232C-1 data out(+)26V.11-2 Data out(-)11
V.11-2 FP output(-)25V.11-2 Data out(+)10
V.11-2 FP output(+)24V.11-2Data in(-)9
NE2 TXD(+) 16 NE2 RXD(-)1
Not Connected8
Not Connected7
NMS (RJ-45)
NMS RXD (-)6
Not Connected5
Not Connected4
NMS RXD (+)3
NMS TXD (-)2
NMS TXD(+)1
Ground4
LCT (USB-B)
D (+)3
D (-)2
Vbus1
Not Connected8
Not Connected7
NE (RJ-45)
NMS RXD (-)6
Not Connected5
Not Connected4
NMS RXD (+)3
NMS TXD (-)2
NMS TXD(+)1
PASOLINK NEOPASOLINK NEO 4646TOPC-E4010E-01-07021
NEO CTRL Interface NEO CTRL Interface
SWHUB2
4
1
NMS
5 LANCONTCPU
3
ASYNCASYNC
LCT/PNMTUSB
19.2kbpsASYNC (NE2)
This port is used for Back-to-Back equipment connection.NE (EM2)
In 2-WAY composition, this port is used.SV2
This port is used for radio connection of equipment.SV1
This port is used for PNMSj or Back to Back 10Base-T( Half duplex)
NMS (EM1)
RolePort Name
Radio SV line384kbps
Store & forward
NEO
SV2SV1
USB
LCT/PNMTUSB Type B
PNMS/NERJ-45
MMC Slot
NE
PASOLINK NEOPASOLINK NEO 4747TOPC-E4010E-01-07021
MODEMMODEM
LANSTM-1SDH128QAM156MB
2 X STM-1
E1/E3
E1/E3
E1
E1
REMARKS
2 X 156MB
100MB
80MB
40MB
20MB
10MB
Transmission Capacity
QPSK
QPSK
QPSK
MODULATION
128QAM
32QAM
16QAM
16QAM
16QAM
16QAM
SDH
PDH
PDH
PDH
PDH
PDH LAN
LAN
LAN
LAN
LAN
LAN
SYSTEM POWER ON/OFFIDU POWER SUPPLY FORWARD ERROR CORRECTION RS (INTERLEAVER) HIGH BER/LOW BER DETECTION EQUALIZATION USING TRANSVERSAL EQUALIZER BB LINEARIZER XPIC FUNCTION FOR DUAL POL TRANSMISSION REF OSCILLATOR FOR XPIC ODU SYNCHRONIZATION
QPSK/16QAM/32QAM/128QAM MODULATION/DEMODULATION
PASOLINK NEOPASOLINK NEO 4848TOPC-E4010E-01-07021
INDICATORS INDICATORS -- MODEMMODEM
IF CABLE OPEN (BLINKS)
ODU MIS-MATCH
APC ALM
INPUT IF LOW ALM (From IDU)
RX RF LEVEL LOW ALM
TX RF POWER LOW ALM
ODU (RED)
IF CABLE SHORT (BLINKS)
Loss of Radio Frame Sync
LOW BER ALM
HBER ALM
DEM ALM
MOD ALM
MD/CBL (RED)XPIC FUNCTION OFF
XPIC RESET
TX STATUS OF (1+1)TX STATUS (Green)
RX STATUS OF (1+1)RX STATUS (Green)
DC POWER ONPOWER (GREEN)
PASOLINK NEOPASOLINK NEO 4949TOPC-E4010E-01-07021
MODEM MODEM CONNECTORS & SWITCHESCONNECTORS & SWITCHES
50 OhmsImpedance:
TNC (Female)Connector:
-48VDC Power :
140 MHzRX Frequency:
340 MHzTX frequency:
IF IN / OUT
FOR XPIC BETWEEN IDUs
75 OhmsImpedance:
IEC 169-29(1.0/2.3)Connector:
5 MHzREF FREQ:
140 MHzFrequency:
XIF IN/ OUT
XPIC Reset IN (+)8
XPIC CONTROL( D-SUB 15 PIN Female)
XPIC SV RXD(-)
XPIC SV TXD(-)
XPIC SEL OUT(+)
XPIC SEL IN(+)
Ground
XPIC SC RXD(+)
XPIC SV TXD(+)
15
14
13
12
11
10
9
Ground7
XPIC Reset Out(+)6
XPIC Reset out (-)5
FOR XPIC BETWEEN IDUs
XPIC Reset IN(-)4
Ground3
XPIC SEL OUT(-)2
XPIC SEL IN(-)1
Molex M5569-04A1 Connector
-48 V (-40.5 to -57)4
Ground3
-48 V (-40.5 to -57)2
Ground1
SELV (DC IN) 4 Pin
FRAME GROUND
GROUND TERMINAL
ON / OFF SWITCH
POWER
PASOLINK NEOPASOLINK NEO 5050TOPC-E4010E-01-07021
16E1 & 2PORT LAN INTFC FOR PDH48E1 INTFC FOR PDH2X E3 & 3 PORT LAN INTFC FOR PDH
4 PORT LAN INTFC FOR PDH
PASOLINK NEOPASOLINK NEO 5151TOPC-E4010E-01-07021
PDH INTFC PDH INTFC 16E1 & 2PORT LAN16E1 & 2PORT LAN
N/A
32 QAM
156MBN/A
100MB N/A
80MB
16QAMQPSK
40MB
20MB
N/A
10MB
128 QAM16 QAMQPSKTransmission Capacity
75/120 ohm (S/W selectable)
PDH
2 x D-Sub (37 pin)Connector
75 Ohms, Unbalance120 Ohms Balance
Impedance(S/W Selectable)
2.048Mpps +/_ 50ppmBit Rate
Up to 16 E1sInput / Output signal
E1 INTFC
2 x RJ-45Connector
Store and ForwardingForwarding Mode
Shared with E1 Channels
Transmission Rate
Full Duplex or Half Duplex
Flow Control
10/100 Base-T(X)Input / Output signal
LAN INTFC (2 ports)
E1 x 16 Channels (D-Sub(37pin) x 2,
10/100BASE-T(X) x 2 Ports (RJ-45 x 2), Auto-Negotiation / Auto-MDI/MDIX
PASOLINK NEOPASOLINK NEO 5252TOPC-E4010E-01-07021
E1 x 48 Channels (MDR(68pin) x 3
PDH INTFC PDH INTFC 48E148E1
32QAM
32 QAM
156MB
100MB
80MB
40MB
20MB
N/A
16QAMQPSK
10MB
128 QAM16 QAMQPSKTransmission Capacity
PDH
75 Ohms, Unbalance120 Ohms Balance
Impedance(S/W Selectable)
3 x MDR (68 pin)Connector
2.048Mpps +/_ 50ppmBit Rate
Up to 48 E1sInput / Output signal
E1 INTFC
75/120 ohm S/W selectable)
LAN function is not available.
PASOLINK NEOPASOLINK NEO 5353TOPC-E4010E-01-07021
E3 x 1/2 Channels (IEC-Mini, 75 ohm)
PDH INTFC PDH INTFC 2E3 / WS / 2PORT LAN2E3 / WS / 2PORT LAN
TOTAL CAPACITY
64 Kbps to 256 Kbps
8x E1 Channels2 Channels
SC LAN CapacityWayside/ LAN CapacityE3 Capacity
75 Ohms, UnbalanceImpedance
IEC 169-29 (1.0/2.3)Connector
34.368 Mbps +/_20ppmBit Rate
One or two E3 signalsInput / Output signal (main)
2 CHANNEL E3 INTERFACE
75 Ohms, Unbalance120 Ohms Balance
Impedance(S/W Selectable)
D-Sub 37 pinsConnector
1 x E3: 4 x E1 wayside CHRemarks
2 x E3:8 x E1 wayside CH
2.048Mpps +/_ 50ppmBit Rate
Up to 8 E1sInput / Output signal
WAYSIDE(WS) E1 INTFC
Auto Sensing or Fixed
64Kbps, 128Kbps, 256KbpsSC1 to SC4
Store and ForwardingForwarding Mode
2 to 8 Mbps (1 x E2)Share Wayside
2 to 16 Mbps (2 x E3)
2 X RJ 45Connector
Full duplex or half duplexFlow Control
10/100 Base-T(X)Input/Output signal
2 Port LAN INTFC
PDH
N/A
32 QAM
156MB
100MB
80MB16QAM
QPSK40MB
20MB
N/A
10MB
128 QAM16 QAMQPSKTransmission Capacity
WS(E1) x 4/8 Channels (D-Sub(37pin),
75/120 ohm (S/W selectable)
10/100BASE-T(X) x 2 Ports (RJ-45 x 2),
PASOLINK NEOPASOLINK NEO 5454TOPC-E4010E-01-07021
PDH INTFC PDH INTFC 4PORT LAN & E14PORT LAN & E1
75 Ohms, Unbalance120 Ohms Balance
Impedance(S/W Selectable)
D-Sub 37 pinsConnector
2.048Mpps +/_ 50ppmBit Rate
Up to 8 E1sInput / Output signal
E1 INTFC
Auto Sensing or Fixed
Store and ForwardingForwarding Mode
4 X RJ 45Connector
Full duplex or half duplexFlow Control
10/100 Base-T(X)Input/Output signal
4 Port LAN INTFC
LAN & 8E1 SHARED(64M TO 80M)
N/A80MB
LAN & 8E1 SHARED (24M TO 40M40MB
LAN & 4E1 FIXEDN/A100MB
LAN & 8E1 SHARED (4M TO 20M)20MB
N/A
N/A
5E1 LAN NOT SUPPORTED10MB
N/A156MB
32 QAM 128 QAM16 QAMQPSKTransmission Capacity
PDH
E1 x 4/8 Channels (D-Sub(37pin)75/120 ohm (S/W selectable)10/100BASE-T(X) x 4 Ports (RJ-45 x 4)Auto-Negotiation / Auto-MDI/MDIX)
PASOLINK NEOPASOLINK NEO 5555TOPC-E4010E-01-07021
INDICATORS INDICATORS PDH INTFCPDH INTFC
Loss of Signal from MUXLoss of Output signal to MUX is detectedChannel Usage ErrorModule MismatchLAN Link failure
PDHDuplex mode lights / Flash when in Collision (Amber)
LAN link established/Blink when packets are transferred (Green)
LAN signal is in 100BASE-TX Mode (Green)
Loss of Signal from MUXLoss of Output signal to MUX is detectedChannel Usage ErrorModule MismatchAIS SendAIS Received
AIS SendAIS Received
16 E1 & 2-PORT LAN INTFC
48 E1 INTFC
PASOLINK NEOPASOLINK NEO 5656TOPC-E4010E-01-07021
INDICATORS INDICATORS 2E3 / WS / 2PORT LAN2E3 / WS / 2PORT LAN
PDHDuplex mode lights / Flash when in Collision (Amber)
LAN link established/Blink when packets are transferred (Green)
LAN signal is in 100BASE-TX Mode (Green)
Loss of Signal (E3 & WS) from MUXLoss of Output signal to MUX is detectedChannel Usage ErrorModule MismatchLAN Link failureAIS SendAIS ReceivedModule Failure
Duplex mode lights / Flash when in Collision (Amber)
LAN link established/Blink when packets are transferred (Green)
LAN signal is in 100BASE-TX Mode (Green)
Loss of signal(E1) from MUX Loss of output signal to MUX detected
LAN link failureModule mismatch error
Channel Usage Error
PASOLINK NEOPASOLINK NEO 5757TOPC-E4010E-01-07021
16E1 & 2PORT LAN 16E1 & 2PORT LAN -- ConnectorsConnectors
201212223234245256267278289291030113112321333143415351636173718
19
CH 8 - INPUT (+)CH 8 - INPUT (-)CH 7 - INPUT (+)CH 7 - INPUT (-)
CH 6 - INPUT (+)CH 6 - INPUT (-)CH 5 - INPUT (+)CH 5 - INPUT (-)
CH 4 - INPUT (+)CH 4 - INPUT (-)CH 3 - INPUT (+)CH 3 - INPUT (-)
CH 2 - INPUT (+)CH 2 - INPUT (-)CH 1 - INPUT (+)CH 1 - INPUT (-)
CH 8 - OUTPUT (+)CH 8 - OUTPUT (-)CH 7 - OUTPUT (+)CH 7 - OUTPUT (-)
CH 6 - OUTPUT (+)CH 6 - OUTPUT (-)CH 5 - OUTPUT (+)CH 5 - OUTPUT (-)CH 4 - OUTPUT (+)CH 4 - OUTPUT (-)CH 3 - OUTPUT (+)CH 3 - OUTPUT (-)
CH 2 - OUTPUT (+)CH 2 - OUTPUT (-)CH 1 - OUTPUT (+)CH 1 - OUTPUT (-)
GROUND
GROUND
GROUND
GROUND
GROUND
2M IN / OUT-A D-SUB (37 PIN)201212223234245256267278289291030113112321333143415351636173718
19
CH 16 - INPUT (+)CH 16 - INPUT (-)CH 15 - INPUT (+)CH 15 - INPUT (-)
CH 14 - INPUT (+)CH 14 - INPUT (-)CH 13 - INPUT (+)CH 13 - INPUT (-)
CH 12 - INPUT (+)CH 12 - INPUT (-)CH 11 - INPUT (+)CH 11 - INPUT (-)
CH 10 - INPUT (+)CH 10 - INPUT (-)CH 9- INPUT (+)CH 9 - INPUT (-)
CH 16 - OUTPUT (+)CH 16 - OUTPUT (-)CH 15 - OUTPUT (+)CH 15 - OUTPUT (-)
CH 14 - OUTPUT (+)CH 14 - OUTPUT (-)CH 13 - OUTPUT (+)CH 13 - OUTPUT (-)CH 12 - OUTPUT (+)CH 12 - OUTPUT (-)CH 11 - OUTPUT (+)CH 11 - OUTPUT (-)
CH 10 - OUTPUT (+)CH 10 - OUTPUT (-)CH 9 - OUTPUT (+)CH 9 - OUTPUT (-)
GROUND
GROUND
GROUND
GROUND
GROUND
2M IN / OUT-B D-SUB (37 PIN)
Do not connected any cable to the not connected pins
Not Connected8
Not Connected7
LAN RD- (LAN TD -)6
Not Connected5
Not Connected4
LAN RD+ (LAN TD+)3
LAN TD (LAN ED-)2
LAN TD+ (LAN RD+)1
LAN PORTS 1 & 2 (RJ-45 8-Pin)
119
37 20
PASOLINK NEOPASOLINK NEO 5858TOPC-E4010E-01-07021
20
1
21
2
22
3
23
4
24
5
25
6
26
7
27
8
28
9
29
10
30
11
31
12
32
13
33
14
34
1516171819
CH 16 - INPUT (+) CH 16 - INPUT (-)Ground
2M IN / OUT-A MDR (68 PIN)
54
35
55
36
56
37
57
38
58
39
59
40
60
41
61
42
62
43
63
44
64
45
65
46
66
47
67
48
68
4950515253
Ground
CH 16 - OUTPUT (+) CH 16 - OUTPUT (-)CH 15 - INPUT (+)CH 15 - OUTPUT (+)
CH 15 - INPUT (-)CH 15 - OUTPUT (-)
CH 14- INPUT (+)CH 14- OUTPUT (+)CH 13 - INPUT (+)CH 13- OUTPUT (+)
CH 14 - INPUT (-)CH 14 - OUTPUT (-)CH 13 - INPUT (-)CH 13- OUTPUT (-)
CH 12 - INPUT (+)CH 12 - OUTPUT (+)CH 11 - INPUT (+)CH 11 - OUTPUT (+)CH 10- INPUT (+)CH 10- OUTPUT (+)CH 9 - INPUT (+)CH 9- OUTPUT (+)
CH 12 - INPUT (-)CH 12 - OUTPUT (-)CH 11- INPUT (-)CH 11- OUTPUT (-)CH 10 - INPUT (-)CH 10- OUTPUT (-)CH 9 - INPUT (-)CH 9- OUTPUT (-)
CH 8 - INPUT (+)CH 8 - OUTPUT (+)CH 7 - INPUT (+)CH 7 - OUTPUT (+)CH 6- INPUT (+)CH 6- OUTPUT (+)CH 5 - INPUT (+)CH 5- OUTPUT (+)CH 4 - INPUT (+)CH 4- OUTPUT (+)CH 3 - INPUT (+)CH 3 - OUTPUT (+)CH 2- INPUT (+)CH 2- OUTPUT (+)CH 1 - INPUT (+)CH 1- OUTPUT (+)
CH 8 - INPUT (-)CH 8 - OUTPUT (-)CH 7 - INPUT (-)CH 7 - OUTPUT (-)CH 6 - INPUT (-)CH 6 - OUTPUT (-)CH 5 - INPUT (-)CH 5- OUTPUT (-)CH 4 - INPUT (-)CH 4 - OUTPUT (-)CH 3- INPUT (-)CH 3- OUTPUT (-)CH 2 - INPUT (-)CH 2- OUTPUT (-)CH 1 - INPUT (-)CH 1- OUTPUT (-)GroundGroundGround
20
1
21
2
22
3
23
4
24
5
25
6
26
7
27
8
28
9
29
10
30
11
31
12
32
13
33
14
34
1516171819
CH 16 - INPUT (+) CH 16 - INPUT (-)Ground
2M IN / OUT-A MDR (68 PIN)
54
35
55
36
56
37
57
38
58
39
59
40
60
41
61
42
62
43
63
44
64
45
65
46
66
47
67
48
68
4950515253
Ground
CH 16 - OUTPUT (+) CH 16 - OUTPUT (-)CH 15 - INPUT (+)CH 15 - OUTPUT (+)
CH 15 - INPUT (-)CH 15 - OUTPUT (-)
CH 14- INPUT (+)CH 30- OUTPUT (+)CH 13 - INPUT (+)CH 13- OUTPUT (+)
CH 14 - INPUT (-)CH 14 - OUTPUT (-)CH 13 - INPUT (-)CH 13- OUTPUT (-)
CH 12 - INPUT (+)CH 12 - OUTPUT (+)CH 11 - INPUT (+)CH 11 - OUTPUT (+)CH 10- INPUT (+)CH 10- OUTPUT (+)CH 9 - INPUT (+)CH 9- OUTPUT (+)
CH 12 - INPUT (-)CH 12 - OUTPUT (-)CH 11- INPUT (-)CH 11- OUTPUT (-)CH 10 - INPUT (-)CH 10- OUTPUT (-)CH 9 - INPUT (-)CH 9- OUTPUT (-)
CH 8 - INPUT (+)CH 8 - OUTPUT (+)CH 7 - INPUT (+)CH 7 - OUTPUT (+)CH 6- INPUT (+)CH 6- OUTPUT (+)CH 5 - INPUT (+)CH 5- OUTPUT (+)CH 4 - INPUT (+)CH 4- OUTPUT (+)CH 3 - INPUT (+)CH 3 - OUTPUT (+)CH 2- INPUT (+)CH 2- OUTPUT (+)CH 1 - INPUT (+)CH 1- OUTPUT (+)
CH 8 - INPUT (-)CH 8 - OUTPUT (-)CH 7 - INPUT (-)CH 7 - OUTPUT (-)CH 6 - INPUT (-)CH 6 - OUTPUT (-)CH 5 - INPUT (-)CH 5- OUTPUT (-)CH 4 - INPUT (-)CH 4 - OUTPUT (-)CH 3- INPUT (-)CH 3- OUTPUT (-)CH 2 - INPUT (-)CH 2- OUTPUT (-)CH 1 - INPUT (-)CH 1- OUTPUT (-)GroundGroundGround
20
1
21
2
22
3
23
4
24
5
25
6
26
7
27
8
28
9
29
10
30
11
31
12
32
13
33
14
34
1516171819
CH 32 - INPUT (+) CH 32 - INPUT (-)Ground
2M IN / OUT-B MDR (68 PIN)
54
35
55
36
56
37
57
38
58
39
59
40
60
41
61
42
62
43
63
44
64
45
65
46
66
47
67
48
68
4950515253
Ground
CH 32 - OUTPUT (+) CH 32 - OUTPUT (-)CH 31 - INPUT (+)CH 31 - OUTPUT (+)
CH 31 - INPUT (-)CH 31 - OUTPUT (-)
CH 30- INPUT (+)
CH 29 - INPUT (+)CH 29- OUTPUT (+)
CH 30 - INPUT (-)CH 30 - OUTPUT (-)CH 29 - INPUT (-)CH29 - OUTPUT (-)
CH 28 - INPUT (+)CH 28 - OUTPUT (+)CH 27 - INPUT (+)CH 27 - OUTPUT (+)CH 26- INPUT (+)CH 26- OUTPUT (+)CH 25 - INPUT (+)CH 25- OUTPUT (+)
CH 28 - INPUT (-)CH 28 - OUTPUT (-)CH 27- INPUT (-)CH 27- OUTPUT (-)CH 26 - INPUT (-)CH 26- OUTPUT (-)CH 25 - INPUT (-)CH 25- OUTPUT (-)
CH 24 - INPUT (+)CH 24 - OUTPUT (+)CH 23 - INPUT (+)CH 23 - OUTPUT (+)CH 22- INPUT (+)CH 22- OUTPUT (+)CH 21 - INPUT (+)CH 21- OUTPUT (+)CH 20 - INPUT (+)CH 20- OUTPUT (+)CH 19 - INPUT (+)CH 19 - OUTPUT (+)CH 18- INPUT (+)CH 18- OUTPUT (+)CH 17 - INPUT (+)CH 17- OUTPUT (+)
CH 24 - INPUT (-)CH 24 - OUTPUT (-)CH 23 - INPUT (-)CH 23 - OUTPUT (-)CH 22 - INPUT (-)CH 22 - OUTPUT (-)CH 21 - INPUT (-)CH 21- OUTPUT (-)CH 20 - INPUT (-)CH 20 - OUTPUT (-)CH 19- INPUT (-)CH 19- OUTPUT (-)CH 18 - INPUT (-)CH 18- OUTPUT (-)CH 17 - INPUT (-)CH 17- OUTPUT (-)GroundGroundGround
48E1 INTFC 48E1 INTFC -- ConnectorsConnectors
20
1
21
2
22
3
23
4
24
5
25
6
26
7
27
8
28
9
29
10
30
11
31
12
32
13
33
14
34
1516171819
CH 16 - INPUT (+) CH 16 - INPUT (-)Ground
2M IN / OUT-A MDR (68 PIN)
54
35
55
36
56
37
57
38
58
39
59
40
60
41
61
42
62
43
63
44
64
45
65
46
66
47
67
48
68
4950515253
Ground
CH 16 - OUTPUT (+) CH 16 - OUTPUT (-)CH 15 - INPUT (+)CH 15 - OUTPUT (+)
CH 15 - INPUT (-)CH 15 - OUTPUT (-)
CH 14- INPUT (+)CH 46- OUTPUT (+)CH 13 - INPUT (+)CH 13- OUTPUT (+)
CH 14 - INPUT (-)CH 14 - OUTPUT (-)CH 13 - INPUT (-)CH 13- OUTPUT (-)
CH 12 - INPUT (+)CH 12 - OUTPUT (+)CH 11 - INPUT (+)CH 11 - OUTPUT (+)CH 10- INPUT (+)CH 10- OUTPUT (+)CH 9 - INPUT (+)CH 9- OUTPUT (+)
CH 12 - INPUT (-)CH 12 - OUTPUT (-)CH 11- INPUT (-)CH 11- OUTPUT (-)CH 10 - INPUT (-)CH 10- OUTPUT (-)CH 9 - INPUT (-)CH 9- OUTPUT (-)
CH 8 - INPUT (+)CH 8 - OUTPUT (+)CH 7 - INPUT (+)CH 7 - OUTPUT (+)CH 6- INPUT (+)CH 6- OUTPUT (+)CH 5 - INPUT (+)CH 5- OUTPUT (+)CH 4 - INPUT (+)CH 4- OUTPUT (+)CH 3 - INPUT (+)CH 3 - OUTPUT (+)CH 2- INPUT (+)CH 2- OUTPUT (+)CH 1 - INPUT (+)CH 1- OUTPUT (+)
CH 8 - INPUT (-)CH 8 - OUTPUT (-)CH 7 - INPUT (-)CH 7 - OUTPUT (-)CH 6 - INPUT (-)CH 6 - OUTPUT (-)CH 5 - INPUT (-)CH 5- OUTPUT (-)CH 4 - INPUT (-)CH 4 - OUTPUT (-)CH 3- INPUT (-)CH 3- OUTPUT (-)CH 2 - INPUT (-)CH 2- OUTPUT (-)CH 1 - INPUT (-)CH 1- OUTPUT (-)GroundGroundGround
20
1
21
2
22
3
23
4
24
5
25
6
26
7
27
8
28
9
29
10
30
11
31
12
32
13
33
14
34
1516171819
CH 48 - INPUT (+) CH 48 - INPUT (-)Ground
2M IN / OUT-C MDR (68 PIN)
54
35
55
36
56
37
57
38
58
39
59
40
60
41
61
42
62
43
63
44
64
45
65
46
66
47
67
48
68
4950515253
Ground
CH 48 - OUTPUT (+) CH 48 - OUTPUT (-)CH 47 - INPUT (+)CH 47 - OUTPUT (+)
CH 47 - INPUT (-)CH 47 - OUTPUT (-)
CH 46- INPUT (+)
CH 45 - INPUT (+)CH 45- OUTPUT (+)
CH 46 - INPUT (-)CH 46 - OUTPUT (-)CH 45 - INPUT (-)CH45 - OUTPUT (-)
CH 44 - INPUT (+)CH 44 - OUTPUT (+)CH 43 - INPUT (+)CH 43 - OUTPUT (+)CH 42- INPUT (+)CH 42- OUTPUT (+)CH 41 - INPUT (+)CH 41- OUTPUT (+)
CH 44 - INPUT (-)CH 44 - OUTPUT (-)CH 437- INPUT (-)CH 43- OUTPUT (-)CH 42 - INPUT (-)CH 42- OUTPUT (-)CH 41 - INPUT (-)CH 41- OUTPUT (-)
CH 40 - INPUT (+)CH 40 - OUTPUT (+)CH 39 - INPUT (+)CH 39 - OUTPUT (+)CH 38- INPUT (+)CH 38- OUTPUT (+)CH 37 - INPUT (+)CH 37- OUTPUT (+)CH 36 - INPUT (+)CH 36- OUTPUT (+)CH 35 - INPUT (+)CH 35 - OUTPUT (+)CH 34- INPUT (+)CH 34- OUTPUT (+)CH 33 - INPUT (+)CH 33- OUTPUT (+)
CH 40 - INPUT (-)CH 40 - OUTPUT (-)CH 39 - INPUT (-)CH 39 - OUTPUT (-)CH 38 - INPUT (-)CH 38 - OUTPUT (-)CH 37 - INPUT (-)CH 37- OUTPUT (-)CH 36 - INPUT (-)CH 36 - OUTPUT (-)CH 35- INPUT (-)CH 35- OUTPUT (-)CH 34 - INPUT (-)CH 34- OUTPUT (-)CH 33 - INPUT (-)CH 33- OUTPUT (-)GroundGroundGround
134
68 35
PASOLINK NEOPASOLINK NEO 5959TOPC-E4010E-01-07021
2E3 / WS / 2PORT LAN2E3 / WS / 2PORT LAN-- CONNECTORSCONNECTORS
Do not connected any cable to the not connected pins
Not Connected8
Not Connected7
LAN RD- (LAN TD -)6
Not Connected5
Not Connected4
LAN RD+ (LAN TD+)3
LAN TD (LAN RD-)2
LAN TD+ (LAN RD+)1
LAN PORTS 1 & 2 (RJ-45 8-Pin)
CH-1 OUTPUT (-)3718CH-1INPUT (+)
GROUND3314CH-3 INPUT (-)CH-3 OUTPUT (-)3213CH-5 INPUT (+)
CH-1 OUTPUT (+)3617CH-2INPUT (-)
19CH-1 INPUT (-)
CH-2 OUTPUT (+)3415GROUNDCH-2 OUTPUT (-)3516CH-2INPUT (+)
CH-4 OUTPUT (-)3011CH-4 INPUT (+)CH-3 OUTPUT (+)3112CH-4 INPUT (-)
CH-5 OUTPUT (-)289CH-5 INPUT (-)CH-4 OUTPUT (+)2910GROUND
CH-6 OUTPUT (-)267CH-6 INPUT (-)CH-5 OUTPUT (+)278CH-5 INPUT (+)
GROUND245GROUNDCH-6 OUTPUT (+)256CH-6 INPUT (+)
CH-7 OUTPUT (+)223CH-7 INPUT (+)CH-7 OUTPUT (-)234CH-7 INPUT (-)
CH-8 OUTPUT (-)212CH-8 INPUT (-)CH-8 OUTPUT (+)201CH-8 INPUT (+)
WS IN /OUT D-SUB (37 PIN)
PDH
IEC 169-29 (1.0/2.3)OUT
IEC 169-29 (1.0/2.3)IN
E3 CH#
119
37 20
PASOLINK NEOPASOLINK NEO 6060TOPC-E4010E-01-07021
4PORT LAN & E1 4PORT LAN & E1 -- CONNECTORSCONNECTORS
Do not connected any cable to the not connected pins
Not Connected8
Not Connected7
LAN RD- (LAN TD -)6
Not Connected5
Not Connected4
LAN RD+ (LAN TD+)3
LAN TD (LAN RD-)2
LAN TD+ (LAN RD+)1
LAN PORTS (1 to 4) (RJ-45 8-Pin)
PDH
CH-1 OUTPUT (-)3718CH-1INPUT (+)
GROUND3314CH-3 INPUT (-)
CH-3 OUTPUT (-)3213CH-5 INPUT (+)
CH-1 OUTPUT (+)3617CH-2INPUT (-)
19CH-1 INPUT (-)
CH-2 OUTPUT (+)3415GROUND
CH-2 OUTPUT (-)3516CH-2INPUT (+)
CH-4 OUTPUT (-)3011CH-4 INPUT (+)
CH-3 OUTPUT (+)3112CH-4 INPUT (-)
CH-5 OUTPUT (-)289CH-5 INPUT (-)
CH-4 OUTPUT (+)2910GROUND
CH-6 OUTPUT (-)267CH-6 INPUT (-)
CH-5 OUTPUT (+)278CH-5 INPUT (+)
GROUND245GROUND
CH-6 OUTPUT (+)256CH-6 INPUT (+)
CH-7 OUTPUT (+)223CH-7 INPUT (+)
CH-7 OUTPUT (-)234CH-7 INPUT (-)
CH-8 OUTPUT (-)212CH-8 INPUT (-)
CH-8 OUTPUT (+)201CH-8 INPUT (+)
E1 IN /OUT D-SUB (37 PIN)
119
37 20
PASOLINK NEOPASOLINK NEO 6161TOPC-E4010E-01-07021
STM-1 ELECTRICAL FOR SDHSTM-1 OPTICAL FOR SDHSTM-1 2 PORT LAN FOR SDHWS/ SC LAN FOR SDH
GBIT ETHER FOR SDH
PASOLINK NEOPASOLINK NEO 6262TOPC-E4010E-01-07021
INTERFACE INTERFACE -- SDHSDH
N/A
N/A10MB
N/A20MB
N/A40MB
N/A80MB
N/A100MB
128QAMN/A156MB
32 QAM 128 QAM16 QAMQPSKTransmission Capacity
IEC 169-29 (1.0/2.3)CONNECTOR
75 Ohms (Unbalanced)IMPEDANCE
CMICODE
1 Vp_pLEVEL
155.520 MbpsBITRATE
G.703TYPE
STM-1 INTFC (ELECTRICAL) -SPECIFICATIONS SDH
RSOH TERMINATION
RX HITLESS SWITCHING FOR (1+1) PROTECTION CONFIGURATION
AUTOMATIC LASER SHUTDOWN (OPTICAL)
SUB (PROT) SLOTMAIN SLOT
STUFFING CONTROL
1310 NMWAVELENGTH
LCCONNECTOR
NRZCODE
L-1.1: 0 TO -8dBm (TX) / -10 TO -34 dBm (RX)S-1.1: -8 TO -15dBm (TX) / -8 TO -28 dBm (RX)
LEVEL
155.520 MbpsBITRATE
G957TYPE
STM-1 INTFC (OPTICAL) -SPECIFICATIONS
STM-1 ELECTRICAL INTFC
STM-1 OPTICAL INTFC
AUTOMATIC PROTECTION SWITCHING (OPTICAL)
PASOLINK NEOPASOLINK NEO 6363TOPC-E4010E-01-07021
SDH INTFC SDH INTFC INDICATORSINDICATORS
SDHSUB (PROT) SLOTMAIN SLOT
Loss of STM-1 from MUXLoss of Frame of STM-1 signal from MUX or DMRE-BER from MUX or DMRSD from MUX or DMRModule FailureModule Mismatch
LIGHTS GREEN W/O APS
LIGHTS GREEN when Online with APSLIGHTS GREEN when Online with APS
PASOLINK NEOPASOLINK NEO 6464TOPC-E4010E-01-07021
SDH INTFC SDH INTFC OPTICALOPTICAL
1310 NMWAVELENGTH
LCCONNECTOR
NRZCODE
L-1.1: 0 TO -8dBm (TX) / -10 TO -34 dBm (RX)S-1.1: -8 TO -15dBm (TX) / -8 TO -28 dBm (RX)
LEVEL
155.520 MbpsBITRATE
G957TYPE
STM-1 INTFC (OPTICAL) -SPECIFICATIONS
N/A
N/A10MB
N/A20MB
N/A40MB
N/A80MB
N/A100MB
128QAMN/A156MB
32 QAM 128 QAM16 QAMQPSKTransmission Capacity
SDH
LIGHTS GREEN W/O APSWITHOUT APSWITH APS
CHANGE THE SFP MODULE FOR L-1.1 / S-1.1
TWO STM-1 INTFC : ELECTRICAL AND OPTICALRSOH TERMINATION STUFFING CONTROLRX HITLESS SWITCHING FOR (1+1) PROTECTION CONFIGURATIONPERFORMANCE MONITOR (G.826/G.828)AUTOMATIC PROTECTION SWITCHING (OPTICAL)AUTOMATIC LASER SHUTDOWN (OPTICAL)
LIGHTS GREEN when Online with APS
LED OFF when standby with APS
PASOLINK NEOPASOLINK NEO 6565TOPC-E4010E-01-07021
GIGABIT ETHER GIGABIT ETHER -- INTERFACEINTERFACE
1000 Mbits Full Duplex Auto Negotiation fixed
Speed & Duplex
SFP Optical InterfaceConnector
Disable/Enable (Selectable)Link Loss Forwarding
150 MbpsTransmission Rate
ON or OFF (Selectable)Flow Control
1000 BASE-SXInput / Output signal
Gigabit Ether Interface (Optical)
SUB (PROT) SLOTMAIN SLOT
1000 Mbits Full Duplex Auto Negotiation fixed
Speed & Duplex
RJ-45Connector
Disable/Enable (Selectable)Link Loss Forwarding
150 MbpsTransmission Rate
ON or OFF (Selectable)Flow Control
1000 BASE-SXInput / Output signal
Gigabit Ether Interface (Electrical)
SDHGIGABIT ETHER INTERFACE ELECTRICAL OR OPTICALLAN SIGNAL IS ENCAPSULATED IN STM-1 SIGNAL RSOH BYTES AVAILABLE BETWEEN RADIO STATIONSRMON AVAILABLE FOR LINE SIDE NOT RADIO SIDEMAX PACKET SIZE 9600 BYTES
N/A
N/A10MB
N/A20MB
N/A40MB
N/A80MB
N/A100MB
128QAMN/A156MB
32 QAM 128 QAM
16 QAMQPSK
Transmission Capacity
LAN /WS INTFC IN SUB SLOT
OPT
PASOLINK NEOPASOLINK NEO 6666TOPC-E4010E-01-07021
GIGABIT ETHER GIGABIT ETHER -- INTERFACEINTERFACE
1000 BASE-SX OutputOutput (Left)
1000 BASE-SX InputInput (Right)
Gigabit Ether Interface (Optical)
SUB (PROT) SLOTMAIN SLOT
SDH
Do not connected any cable to the not connected pins
DATA-D (-) / DATA-C (-)8
DATA-D(+) / DATA-C (+)7
DATA-B (-) / DATA-A (+)6
DATA-C(-) / DATA-D (-)5
DATA-C (+) / DATA-D (+)4
DATA-B(+) / DATA-A (+)3
DATA-A (-) / DATA-B (-)2
DATA-A(+) / DATA-B (+)1
LAN PORTS (1 to 4) (RJ-45 8-Pin)
LAN LINK FAILURE
GbE OPTICAL OUTPUT INTERRUPTED
SD FROM DMR
EXCESSIVE BER FROM DMR
LOF FROM DMR
LOS FROM DMR
MODULE FAILURE
MODULE MISMATCH
ALARM
PASOLINK NEOPASOLINK NEO 6767TOPC-E4010E-01-07021
SDH INTFC SDH INTFC INDICATORSINDICATORS
IEC 169-29 (1.0/2.3)CONNECTOR
75 Ohms (Unbalanced)IMPEDANCE
CMICODE
1 Vp_pLEVEL
155.520 MbpsBITRATE
G.703TYPE
STM-1 INTFC (ELECTRICAL) -SPECIFICATIONS
SDH
SUB (PROT) SLOTMAIN SLOT
LAN LINK FAILURE
GbE OPTICAL OUTPUT INTERRUPTED
SD FROM DMR
EXCESSIVE BER FROM DMR
LOF FROM DMR
LOS FROM DMR
MODULE FAILURE
MODULE MISMATCH
ALARM
PASOLINK NEOPASOLINK NEO 6868TOPC-E4010E-01-07021
SDH INTFC SDH INTFC 2 PORT LAN2 PORT LAN
Do not connected any cable to the not connected pins
Not Connected8
Not Connected7
LAN RD- (LAN TD -)6
Not Connected5
Not Connected4
LAN RD+ (LAN TD+)3
LAN TD (LAN RD-)2
LAN TD+ (LAN RD+)1
LAN PORTS (1 to 4) (RJ-45 8-Pin)
SDH
SUB (PROT) SLOTMAIN SLOT
TWO LAN PORTS 10/100 BASE TxLAN SIGNAL IS ENCAPSULATED IN STM-1 SIGNAL LAN SIGNAL IS USED IN 2-PORT SHARED MODE
(Installed in Main slot)
WS CHANNEL NOT USED
2 X RJ 45Connector
SEPARATED MODELAN PORT 1 & 2
Auto Sensing or Fixed
Store and ForwardingForwarding Mode
75 Mbps + 75 Mbps100 Mbps + 50 MbpsBest effort + Best effort
Port 1& 2
Full duplex or half duplexFlow Control
10/100 Base-T(X)Input/Output signal
2 Port LAN INTFC
TYPE - C
M . S
PASOLINK NEOPASOLINK NEO 6969TOPC-E4010E-01-07021
SDH INTFC SDH INTFC INDICATORSINDICATORS
75 Ohms, Unbalance120 Ohms Balance
Impedance(S/W Selectable)
D-Sub 37 pinsConnector
2.048Mpps +/_ 50ppmBit Rate
One E1Input / Output signal
E1 WS INTFC
SDH
SUB (PROT) SLOTMAIN SLOT
TWO LAN PORTS 10/100 BASE Tx USED AS SC LAN2.O48 Mbps WAY SIDE SIGNAL
(Installed in Sub slot)
75 /120 ohm (S/W SELECTABLE)
Type -A
Type -B
64/128/256 Kbps (RFCOH)2.048 Mbps (WS not used)
2 X RJ 45Connector
SHARED MODELAN PORT 1 & 2
Auto Sensing or Fixed
Store and ForwardingForwarding Mode
Transmission Rate
Full duplex or half duplexFlow Control
10/100 Base-T(X)Input/Output signal
2 Port LAN INTFC
PASOLINK NEOPASOLINK NEO 7070TOPC-E4010E-01-07021
SDH INTFC SDH INTFC INDICATORSINDICATORS
Do not connected any cable to the not connected pins
Not Connected8
Not Connected7
LAN RD- (LAN TD -)6
Not Connected5
Not Connected4
LAN RD+ (LAN TD+)3
LAN TD (LAN RD-)2
LAN TD+ (LAN RD+)1
LAN PORTS (1 to 2) (RJ-45 8-Pin)
SDH
SUB (PROT) SLOTMAIN SLOT
5GROUND
WS CH OUTPUT (-)83WS CH OUTPUT (+)
GROUND94GROUND
GROUND72GROUND
WS CH INPUT (-)61WS CH INPUT (+)
WS IN /OUT D-SUB (37 PIN)
PASOLINK NEOPASOLINK NEO 7171TOPC-E4010E-01-07021
SDH INTFC SDH INTFC INDICATORSINDICATORS
SDH
SUB (PROT) SLOT
MAIN SLOT
WS AIS Received / send
LAN Link Failure
Module Failure
Module Mismatch
Loss of signal (LOS) from DTE
ALARM
Duplex mode lights / Flash when in Collision (Amber)
LAN link established/Blink when packets are transferred (Green)
LAN signal is in 100BASE-TX Mode (Green)
Lights when wayside channel is used
PASOLINK NEOPASOLINK NEO 7272TOPC-E4010E-01-07021
OUT DOOR UNIT
PASOLINK NEOPASOLINK NEO 7373TOPC-E4010E-01-07021
OUT DOOR UNITOUT DOOR UNIT
TX RF BPF
MPX
RX RF BPF
RF AMPUP CONV
LO
DC-DC CONV
DOWN CONV
CONTROL
LNA
PASOLINK NEOPASOLINK NEO 7474TOPC-E4010E-01-07021
OUT DOOR UNIT (6OUT DOOR UNIT (6--52 GHz)52 GHz)
Frame Ground
IF IN/OUT
Turn OFF the IDU DC power before removing the IF cable
Turn OFF the IDU DC power before removing the IF cable
RX LEV MONITOR
RF IN/OUT COAXIAL TYPE (6-8 GHz)
RF IN/OUT 10 52 GHz
RF IN/OUT WG TYPE (6-8 GHz)
ANTENNA DIRECT MOUNT TYPE
PASOLINK NEOPASOLINK NEO 7575TOPC-E4010E-01-07021
ODU OUT LINEODU OUT LINE
6/7/8 GHz: N-TYPE (Female) Coaxial interface6 GHz: PDR-70
18-23 GHz: PBR-22026 GHz: PBR-260
Layout and arrangement may vary with frequency band
RF IN / OUT
OUT DOOR UNIT - TRP [ ]G 1B
IF CKT
H0416[ ]
H2234[ ]
H2233[ ]
H2232[ ]
H2231[ ]
H2230[ ]
H2229[ ]
H2228[ ]
H2227[ ]
H2205[ ]
H2225[ ]
H2204[ ]
H2203[ ]
H2202[ ]
RF CKT
NWA-009042[ ]26GHz
NWA-009040[ ]23GHz
NWA-009038[ ]18GHz
NWA-009036[ ]15GHz
NWA-009046[ ]32GHz
NWA-009044[ ]28GHz
NWA-009048[ ]38GHz
NWA-009050[ ]52GHz
NWA-009034[ ]13GHz
NWA-009032[ ]11GHz
NWA-009030[ ]10GHz
NWA-009028[ ]8GHz
NWA-009026[ ]7GHz
NWA-009024[ ]6GHz
PSModule Name
7/8 GHz: PDR-8410/11 GHz: PDR-10013 GHz: PBR-120 or PBR-14015 GHz:PBR-140
28/32/38 GHz: PBR-320
PASOLINK NEOPASOLINK NEO 7676TOPC-E4010E-01-07021
TYPICAL ODU BLOCK DIAGRAMTYPICAL ODU BLOCK DIAGRAM
Input IF signal consists of:340 MHz TX IF
140 MHz RX IF
10MHz Control
DC power -48V
Each of the input IF signal components are separated in the MULTIPLEXER using separation filters. DC voltage is supplied to the DC-DC CONV to produce regulated DC voltages required in the ODU.The 10 MHz control signal which is ASK modulated is sent to the Control circuit, where the ODU controls like TX Power, RF Frequencies etc. are implemented. The Alarms in ODU are collected in the Control module and sent to the IDU using the ASK modulated 10 MHz signal.
Output IF signal consists of:
10MHz Alarm/Response
APC ALM
RX LEV ALM
TX PWR ALMIF INPUT ALM
PASOLINK NEOPASOLINK NEO 7777TOPC-E4010E-01-07021
PASOLINK CONNECTORSPASOLINK CONNECTORS
TX 340 MHzRX 140 MHzDC 10MHz ControlASK
PASOLINK NEOPASOLINK NEO 7878TOPC-E4010E-01-07021
PASOLINK NEOPASOLINK NEO 7979TOPC-E4010E-01-07021
Possible Configurations
HYBHLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX) M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F1
F1'
HYB HLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX)M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F1
F1'
F1
F1'
Single Antenna HS System
HLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX) M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F1
F1'
HLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX)M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F1
F1'
F1
F1'
Two Antenna HS System
PASOLINK NEOPASOLINK NEO 8080TOPC-E4010E-01-07021
HLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX)M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F2
F2'
F1
F1'
HLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX) M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F2
F2'
HYBF2
F2'
Hybrid Diversity System
HLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX)M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F2
F2'
F1'
F2
F2'
HLSW
MOD
DEM
ODU-2(TX)
ODU-2(RX) M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F1
F1'
F1
Two Antenna Twin Path System
Possible Configurations
PASOLINK NEOPASOLINK NEO 8181TOPC-E4010E-01-07021
Possible Configurations
OMT
MOD
DEM
ODU-2(TX)
ODU-2(RX) M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F2
F2'
MOD
DEM
ODU-2(TX)
ODU-2(RX)M
PX
MOD
DEM
ODU-1(TX)
ODU-1(RX)
MPX
F1
F1'
F2
F2'
F1
OMT
F2'
F2 F1'
V
H
V
H
(2+0) System using OMT
PASOLINK NEOPASOLINK NEO 8282TOPC-E4010E-01-07021
ANTENNA INDIRECT MOUNTING COAXIAL (1+0) ANTENNA INDIRECT MOUNTING WAVEGUIDE (1+0)
ANTENNA DIRECT MOUNTING (1+0)
6/7/8 GHz
ODU MOUNTING FOR (1+0)
PASOLINK NEOPASOLINK NEO 8383TOPC-E4010E-01-07021
ANTENNA INDIRECT MOUNTING
COAXIAL 6/7/8 GHz 2 (1+0)
ANTENNA DIRECT MOUNTING 2 (1+0)
ODU MOUNTING FOR 2 (1+0)
ANTENNA INDIRECT MOUNTING
WAVEGUIDE CONNECTION 2 (1+0)
PASOLINK NEOPASOLINK NEO 8484TOPC-E4010E-01-07021
ANTENNA INDIRECT MOUNTING
WAVEGUIDE CONNECTION
2(1+1)
ODU MOUNTING FOR 2(1+1)
PASOLINK NEOPASOLINK NEO 8585TOPC-E4010E-01-07021
ANTENNA INDIRECT MOUNTING
COAXIAL 6/7/8 GHz (1+1)
ANTENNA DIRECT MOUNTING (1+1)
ODU MOUNTING FOR (1+1)
ANTENNA INDIRECT MOUNTING
WAVEGUIDE CONNECTION (1+1 SD)
6/7/8 GHz
Loss 3.7 dB
11 52 GHz
Loss11/13/15/18/23 GHz 3.5 dB26/32/38 GHz 3.8 dB 52 GHz 4.5 dB
PASOLINK NEOPASOLINK NEO 8686TOPC-E4010E-01-07021
PASOLINK NEOPASOLINK NEO 8787TOPC-E4010E-01-07021
AUTOMATIC TX POWER CONTROL
The automatic transmit power control (ATPC) function automatically varies the TX output power according to path conditions. Fading exerts heavy influences on propagation, causing the receive signal level at the opposite station to vary. The ATPC function operates by controlling the transmit output power of the opposite station according to the variation of the received signal level at the local station.
The receive signal level variation at the opposite station is informed to the local station using the ATPC bits in the overhead. To implement ATPC, the receiving level (RX IN LEV) is detected by the receiver (RX) and passed on to the CPU in the CTRL circuit of the MODEM module. The CPU then determines whether the transmit output power needs to be controlled. This is based on the transmit output power, the minimum and maximum values of the output control range, and the receiving threshold level that were previously specified using the LCT or PNMT.
The function of the control signal (POWER CONT), is to maintain the RX signal level by lowering or raising the TX output power of the opposite station. This control signal is based on the result of comparison between the current receiver input level and the preset receiving threshold level.
Transmission level control can be used not only for setting the same operation (ATPC-ATPC) between own station and opposite station but also for operation in combination of stations with different operation (MTPC-ATPC, ATPC-MTPC) between own station and opposite station. The station set in MTPC mode is not controlled by the information from opposite station but is fixed in its transmitting output level.Even if the station is set in the MTPC mode, the opposite station is likely to be set in the ATPC mode. Therefore setting of the RX Threshold (Receiving threshold level) is required for controlling the transmission level of the opposite station. Between the stations that are respectively set in the MTPC mode, however, the setting is disabled.
Automatic Transmit Power Control Operation
PASOLINK NEOPASOLINK NEO 8888TOPC-E4010E-01-07021
ATPC Operation
T
X
O
U
T
R
X
L
e
v
e
l
RX Threshold(-60dBm)
-55dBm
H
y
s
t
e
r
e
s
i
s
(
5
d
B
F
i
x
e
d
)
ATPC TX MAX
ATPC TX MIN
Up Mode
Down Mode
The ATPC Control transmits the information on the receiving level to the opposite station and controls the transmission level of its own station in accordance with the receiving level of the opposite station.
The ATPC Control can be used in several configurations:
ATPC - ATPCMTPC - ATPCATPC - MTPC
Station - A
Station - B
STN - A STN - B
MTPCRX Threshold = -60dBm
ATPC
When RSL reaches -60dBm at STN B STN-A starts to increase the TX power in 1 dB steps, this process continues until the ATPC TX MAX level is reached. Any RSL drop below this point is not compensated. In the UP Mode ATPC operation starts at -55dBm because of the fixed 5dB hysteresis.
Fading depthdeep shallow
deep shallow
PASOLINK NEOPASOLINK NEO 8989TOPC-E4010E-01-07021
ATPC Operation
1. Reduced interference to adjacent/other systemsSince the transmitted power may be be lower with ATPC, the amount of interference that may be introduced to adjacent/other systems will also be lower. However, adjacent systems that do not employ ATPC may cause interference to systems that use ATPC.
2. " Up-fading " characteristic is improvedSince the system normally transmits at a lower power level, it is more resilient to " UP-fading " conditions.
3. Residual BER performance is improvedThe residual BER performance is improved because of reduced non-linear distortion since the amplifier can be operated well within the linear region at lower transmitter output levels.
4. Increased capacity for star network configurationsLower transmitting levels reduces the required angular discrimination required at the receiving station. This allows transmission of more RF channels
Advantages
PASOLINK NEOPASOLINK NEO 9090TOPC-E4010E-01-07021
SERVICE CHANNELSSERVICE CHANNELS
Available Service Channels in PASOLINK NEO radio overhead frame
Shared with SC LANPDH E3 INTFC Up to 8 E1WAYSIDE
SC LANLAN /WS INTFC 1 X E1 ( In Sub Slot)
OVERHEAD SERVICE CHANNELS
RSOH (SDH)SC LAN*
64k 128K 256K
384 kbpsNMS
E1, F1, DCCr64Kbit/s( Contra / Co-directional selectable) 100ohmsV.11-2SC2
E1, F1, DCCr64Kbit/s ( Contra / Co-directional selectable) 100 ohmsV.11-1SC1
E1, F1, 9.6 KbpsRS-232C-2SC4
E1, F1, 9.6 KbpsRS-232C-1SC3
Engineering Order Wire (IDU-IDU), Level: -6 dBm, 600 ohmsEOWSC5
* Service channels can be connected back-to-back at repeater stations.* When the mounted interface card support LAN ports, then SC LAN traffic can be assigned
* Service Channels are available from High density D-Sub 44-pin connector
PASOLINK NEOPASOLINK NEO 9191TOPC-E4010E-01-07021
SERVICE CHANNELSSERVICE CHANNELS
M UX PASO LINK NEO M UX
E1 (M UX) E1 (DM R)F1 (DM R)F1 (M UX)
E1 (M UX)F1 (M UX)
DC C r (M UX)
PASO LINK NEO
V.11DSC 1 TO 4V.11 & RS-232CDC C r (DM R) DC C r (M UX)
SC LAN DSC 1 TO 4
V.11 & RS-232CV.11 & RS-232C
DSC 1 TO 4SC LAN
V.11 & RS-232C
SDH
PDH
PASOLINK NEOPASOLINK NEO 9292TOPC-E4010E-01-07021
Principle of BB LinearlizerPrinciple of BB Linearlizer
INTFC MIXBB LRZDPU MIX AMPMIXAMP
Gain/Phase
AM-AM
AM-PM
INPUT
Gain/Phase
AM-AM
AM-PM
INPUT
IDU ODU
compensate AM-AM and AM-PM of power amplifier
improve Spectrum characteristic NOT FOR QPSK
PASOLINK NEOPASOLINK NEO 9393TOPC-E4010E-01-07021
LOOPLOOP--BACK BACK --PDHPDH
(a) E1 CH # near-end loopback at the PDH INTFC module from the LCT(b) E1 CH# far-end loopback at the PDH INTFC module from the LCT(c) IF loopback (IF-LB) at the MODEM module (Local only)(d) E1 CH# far-end loopback at the PDH INTFC Module from PNMTj/PNMSj
Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent stations from the PNMSj and PNMTj are disabled.
PASOLINK NEOPASOLINK NEO 9494TOPC-E4010E-01-07021
ETHERNET CONFIGURATIONS
PASOLINK NEOPASOLINK NEO 9595TOPC-E4010E-01-07021
ETHERNET CONFIGURATIONS
PASOLINK NEOPASOLINK NEO 9696TOPC-E4010E-01-07021
All data multiplexed except TS0/TS16, CRC yesPCM-30COnOnOn
All data multiplexed except TS0/TS16, no CRC PCM-30OnOffOn
All data multiplexed except TS0,CRC yesPCM-31COffOnOn
All data multiplexed except TS0, no CRCPCM-31OffOffOn
All data bits are multiplexedUnframedOff
DescriptionTypeCASCRCFraming
8bit
32TS:256bits/125us
Framing & CRC etc.Multi frame structure
Signaling CHChannel Associated Signaling(CAS)Multi frame structure
TXD +1 TXD +1 RXD -2RXD +1
TXD +1 TXD +14TXD +3
TXD +1 TXD +1 TXD -65
TXD +1 TXD +1 TXD -2TXD +1
TXD +1 TXD +14RXD +3
TXD +1 TXD +1 RXD -65
TXD +1 TXD +1 RXD -2RXD +1
TXD +1 TXD +14TXD +3
TXD +1 TXD +1 TXD -65
TXD +1 TXD +1 RXD -2RXD +1
TXD +1 TXD +14TXD +3
TXD +1 TXD +1 TXD -65
TXD +1 TXD +1 RXD -2RXD +1
TXD +1 TXD +14TXD +3
TXD +1 TXD +1 TXD -65
TXD +1 TXD +1 TXD -2TXD +1
TXD +1 TXD +14RXD +3
TXD +1 TXD +1 RXD -65
TXD +1 TXD +1 TXD -2TXD +1
TXD +1 TXD +14RXD +3
TXD +1 TXD +1 RXD -65
TXD +1 TXD +1 TXD -2TXD +1
TXD +1 TXD +14RXD +3
TXD +1 TXD +1 RXD -65
MDIWiring
MDIWiring
MDIWiring
MDIWiring
MDIXWiring
MDIXWiring
MDIXWiring
MDIXWiring
CrossCable
Straight CableCrossCable
Straight Cable
The cable selection between the LAN port and the external equipment depends on the Mode setting. If Auto Negotiation is selected it is possible to use either Straight or Cross cable. If MID / MIDX is selected it is necessary to select the correct cable for connection
G732 Frame Structure
ETHER OVER E1 33
PASOLINK NEOPASOLINK NEO 9797TOPC-E4010E-01-07021
ALARM TABLEALARM TABLE
EXCESSIVE BER DETECTED FROM MUXE-BER (MUX)ODU RECEIVED RF LEVEL LOWRX LEV ALM
UN AVAILABLE CONDITION FROM RADIO EXISTSUAE
XPIC REF FREQUENCY IS LOSTXREF ALMCABLE EQUALIZER CONTROL IS LOST IN MODEMCABLE EQUALIZER
LOSS OF STM-1 FRAME DETECTED FROM RADIOLOF (DMR)MODEM UNIT AILUREMODULE ALM
XPIC INPUT DC VOLTAGE HIGH OR LOWINPUT VOLTAGEXPIC CONTROL FAILUREXCTRL ALMPOWER SUPPLY FAILURE (1+1) ONLYPOWERSUPPLY
CARRIER / FRAME ASYNCH AT MODEMDEM ALMSTM-1 OUTPUT CONTROL APPLIED (MS-AIS GENERATION)OUTPUT CONTROLMODEM PLL UNLOCK, OUTPUT DOWN, CLOCK LOSSMOD ALM
LOSS OF WS CH # INPUT SIGNALWS CH INPUT LOSSPDH INTFCWSBB LNZ CONTROL IS LOSTLINEARIZER
XIF SIGNAL IS LOW OR LOSTX IF ALMIF CABLE CONNECTED TO ODU IS SHORT CIRCUITIF CABLE SHORT
WS SIGNAL DETECTED IN NOT USED WS CHWS CH USAGE ERRORINTFC HARDWARE FAILUREMODULE ALMAIS IS GENERATED IN WS CH#WS AIS GENERATEDMOUNTED INTFC DIFFERENT FROM CONFIGUREDTYPE MISMATCHAIS RECEIVED ON WS CH #, FROM MUX WS AIS RCVDINTFC NOT MOUNTEDUNEQUIPPED
COLLISION OCCURRED IN LAN LAN COLLISIONAIS GENERATED ON CH # (E1 OR E3)AIS GENERATED CH #LAN LINK FAILURELAN LINKAIS RECEIVED FROM CH # FROM MUX (E1 OR E3)AIS RCVD CH #
LANLOSS OF INPUT SIGNAL CH# FROM MUX ( E1 OR E3)INPUT LOSS CH #
CONTROL UNIT TOTAL ALARMCTRL ALM
REMOTE LAN LINK FAILURE DETECTEDLINK LOSS FORWARDINGE1 SIGNAL DETECTED IN CH SET TO NOT USEDCH USAGE ERROR CH#
APS SW FAILUREAPS SW FAILEARLY WARNING CONDITION DETECTED IN CH #EARLY WARNINGUNAVAILABLE CONDITION FROM RADIO EXISTSUAE (DMR)LOW BER LEVEL DETECTED IN MODEMLOW BERUNAVAILABLE COMDITION FROM MUX EXISTSUAE (MUX)HIGH BER LEVEL DETECTED IN MODEMHIGH BERTX FAIL ; NO STM-1 OUT PUT TO MUX TF ALMFRAME ID MISMATCHFRAME IDSIGNAL DGRADE DETECTED FROM RADIOSD (DMR)LOSS OF RADIO FRAME SYNCHRONZATION IN MODEMLOF
LOSS OF STM-1 SIGNAL DETECTED FROM RADIOLOS (DMR)MODEM UNIT NOT MOUNTEDUN EQUIPPEDSIGNAL DEGRADE DETECTGED FROM MUXSD (MUX)MODEMEXCESSIVE BER DETECTED FROM RADIO DIRECTIONE-BER (DMR)REFERENCE LO SIGNAL IS LOSTLO REF ALM (XPIC)
LOSS OF STM-1 FRAME FROM MUXLOF (MUX)ODU CPU FAILURE OR IF CABLE OPENODU CPU/CBL OPN ALMLOSS OF STM-1 SIGNAL FROM MUXLOS (MUX)ODU LOCAL OSCCILATOR UNLOCKEDAPC ALMINTFC UNIT FAILUREMODULE ALMTX IF INPUT LEVEL DECREASEDTX INPUT ALMMOUNTED INTFC DIFFERENT FROM CONFIGUREDTYPEMISMATCHODU OUT POWER DECREASEDTX PWR ALMSDH INTFC NOT MOUNTEDUNEQUIPPEDODU TOTAL ALARMODU ALM
SDH INTFCODUDESCRIPTIONALM ITEMDESCRIPTIONALM ITEM
PASOLINK NEOPASOLINK NEO 9898TOPC-E4010E-01-07021
Polarization Change
When ODUs are mounted on to t h e N E C H y b r i d , o n l y V polarization is used. The Hybrid is set to V polarization when sh ipped f rom the fac to ry .Rotate the TRANSITION HUB plates as shown in the figure to the right to change polarization.
V - Polarization
H - Polarization
Note Polarization can be changed if required to avoid interference
When shipped from factory the Guide Pin is fixed to the Vertical plate. To change polarization rotate the ODU and screw in the Guide Pin to the hole in the plate marked H.
PASOLINK NEOPASOLINK NEO 9999TOPC-E4010E-01-07021
I/0 BOARD FOR 48 E1 & 16E1
MDR(16E1) D-Sub (2x8E1) Conversion Card
I/O BOARD FOR BNC (75 OHMS UNBALANCE)
PASOLINK NEOPASOLINK NEO 100100TOPC-E4010E-01-07021
NEO POWER SUPPLY
SPARE FUSE
PASOLINK NEOPASOLINK NEO 101101TOPC-E4010E-01-07021
NEO POWER SUPPLY WITH DC-DC CONV
PASOLINK NEOPASOLINK NEO 102102TOPC-E4010E-01-07021
DCDC--DC CONVDC CONV
SPARE FUSE
PASOLINK NEOPASOLINK NEO 103103TOPC-E4010E-01-07021
LCT LCT -- MENUMENU
Alarm / StatusEquipment SetupInventoryAUX I/OMaintenanceProvisioningMeteringPMON (Current)PMON (History)
CH Setting-1
CH Setting-2
BER Threshold Setting
SC Assignment
LAN Port Setting
TX Power Control
Condition for TX/RX SW
Relay Setting
TCN Threshold (15min)TCN Threshold (1day)
PMON Select
Others
User Interface
Redundancy Setting
INTFC (Work)
INTFC (Prot)
XPIC Usage
APS Function
Modulation Scheme
Transmission Capacity
TX RF Frequency[MHz]RX RF Frequency[MHz]
Frame ID
TX Power Control
STM-1 Setting
ALS Function
Condition for APS
LAN Port Usage (Main)
LAN Capacity (Main)
PDH E1 with LANPDH E1
PDH E3 with LANSDH STM-1
1 + 1 (Hot Standby TERM)1 + 0 (TERM)
1 + 1 (Twin Path TERM)
48 x E1 PKG16 x E1 Standard PKG (E/W LAN)
4 Port LAN with E1
4 Port LAN with E1
2 WAY PDH (REP)
STM-1 (Optical)STM-1 (Electrical)1 x E3 +4E1 PKG (E/W LAN)2 x E3 +8E1 PKG (E/W LAN)
E3 Setting
STM-1 (Optical) for APSNot Used
WS / LAN
Used (Main Master)Not Used
Used (SUB Master)
UnavailableAvailable
16QAMQPSK
32QAM128QAM
10 [MB]20 [MB]40 [MB]80 [MB]80 [MB]100 [MB]156 [MB]
Frame ID 1 - 32
ATPCMTPC
NOT USEDP1-2 Shared/1 Port Only(Main)P1-2 Shared/1 Port Only(SC)P1-2 Separated(Main)
CH # LAN ( Status)CH #
CH Usage Error Report
AIS Activation Condition
AIS Generation ReportAIS Received ReportAIS Received Condition
E1 Port Impedance (CH#)
High BER ThresholdLow BER ThresholdE-BER (DMR)SD (DMR)E-BER (MUX)SD (MUX)
ATPC Trehsold Level [dBm]Additional ATT [dB]ATPC Range [MAX] [dB]ATPC Range [MIN] [dB]ATPC Power Mode
ATPC Trehsold Level [dBm]Additional ATT [dB]
MTPC TX Power [dB]
MS - AIS Generation
ALS FunctionALS Interval
TX SW Priority
RX SW PriorityRX SW Maintenance Mode
RX SW Condition Early Warning
APS Maintenance ModeAPS Condition-SF(PROT)APS Condition-SD (B1)
Lock in Count (times)Lock in Usage
Lock in Detect Time (mins)Lock in Hold Time (mins)
HK OUT 1 to 4 setting
CLUSTER ALM OUT 1 to 4 settingPASOLINK ALM OUT settingCLUSTER ALM IN 1 to 4 setting
RX Level TCN Threshold [dBm]SES Activation
EOW2 Wxternal SettingAlarm Correlation Capability
Switching Function2M Frame
Port UsageSpeed & DuplexFlow ControlCollision ReportLink Loss Forwarding
LAN PORT SETTING
P
o
r
t
1
P
o
r
t
2
RX SW Manual ControlTX SW Manual ControlTX Mute ControlCW ControlAPS Manual Control
DADE Adjust
Linearizer Control
XPIC Control
RF SettingAntenna Alignment Mode
Main Loopback(Near End)IF Loopback
Main Loopback(Far End)
ALS Restart
Maintenance
OFFLine Maintenance
Download Configuration File
Password SettingDate / Time Setting
PMON Clear
CPU Reset
Download Program FileDownload Equip Config FileUpload Configuration FileUpload Equip Config File
Maintenance -1
Maintenance -2
ProvisioningEquipment Setup
XPIC Condition - Local Fail REF LO>>Self LONormal InvertOFF OFF
Mute
30% 15%
Disabled Enabled
RL-3RL-4RL-5RL-6
Manual ForcedPriority High Priority LowInclude SD Exclude SDUsed Notused
Include EW Exclude EWManual Forced
Non Priority Priority No.1
Hold Max Min
Disabled180Sec 300Sec60Sec
Enabled
Disabled Enabled
Disabled EnabledReport Not ReportON OFF
Used Not Used
Disabled Enabled
120 Ohms 75 OhmsLOF+HBER LOFAlarm Status
Report Not Report
Used Not Used
LCT MAIN MENU