    Target Audience

    The program is intended for staffs to operating andmaintaining NEC NEO&NEO/c Microwave Equipment

    PrerequisitesHaving at least one year experience in installingand testing of RF equipment Being familiar with Windowsoperation system;Having the basic knowledge of telecommunications

    Objectives

    On completion of this program, the participants will be able to:Describe the structure of the NEC NEO, direct or carry ourRoutine maintenance and troubleshooting for NEC Pasolink MW

    Course target

  • 7/28/2019 O&M-PASO NEO-tian

    3/56

    3

    NEC-MIC-0807506 Ver.2.1

    Maintenance Test sets

    Accessories preparation

    --Digital meter3--Bit error meter4

    --Screwdriver5

    --T type hexagonal driver6

    --Torque wrench7

    --PC for LCT Terminal8

    ANRITSUMN95DOptical Variableattenuator

    2

    ANRITSUMp1570ASDH analyzer1

    ManufactureModel

    number

    Model typeNo

    Note: - mean Customer can prepare the tool by themselves, Nospecial requesting about the model number & manufacture

  • 7/28/2019 O&M-PASO NEO-tian

    4/56

    4

    NEC-MIC-0807506 Ver.2.1

    The problems existing during installation:

    1, Prompt problem due to poor installation or setting mistakesThis problem will find out immediately and fix after installation.For instance: IF cable opening, circuit shorting; wrong CH setting

    2, Potential problems due to poor installation or setting mistakesThis problem remains on your system and not easy be find out.For instance: poor antenna fix, poor grounding system; wrongE1 impedance setting.

    Most of installation and manufacture problems will happen within one annualyear operation.After that system goes into normal operation period.

    Maintenance Tasks

  • 7/28/2019 O&M-PASO NEO-tian

    5/56

    5

    NEC-MIC-0807506 Ver.2.1

    Maintenance Equipment

    482(W)x44(H)x190(D)mm 1+0

    482(W)x44(H)x230(D)mm 1+1

    482(W)x44(H)x240(D)mmIDU

    SAME with NEO 239(W)x247(H)x68(D)mm237(W)x237(H)x101(D)mmODU

    NEO /c (NEO PDH sample version)NEO

  • 7/28/2019 O&M-PASO NEO-tian

    6/56

    6

    NEC-MIC-0807506 Ver.2.1

    1. Routine Maintenance:

    Through routine activity to avoid links problems happen.

    2. Troubleshooting:

    When problem has happen, or equipment fault,Fix problem, Recover links service.

    Two Maintenance Tasks in ordinary work

    Maintenance Tasks

  • 7/28/2019 O&M-PASO NEO-tian

    7/56

    7

    NEC-MIC-0807506 Ver.2.1

    1. Routine Maintenance

    Meter reading

    Reading the RSL metering test result and check the linkstatus.

    Link performance monitoringCheck the link performance, 15min and 1 day historymonitoring data record can help to analysis the linkperformance.

  • 7/28/2019 O&M-PASO NEO-tian

    8/56

    8

    NEC-MIC-0807506 Ver.2.1

    1. Routine Maintenance

    Routine maintenance need use NMS by

    software PNMSJ (remote checking) orPNMTJ (local checking).

    Managed Di gi t al Radi oManaged Di gi t al Radi o

    Net wor kNet wor k

    Remote Client Access

    adminadmin

    demodemo

    Filtered TrapsFiltered Traps

    UpperUpperNMSNMS

    Remote accessRemote access by Pby PNMSNMSJJ Local accessLocal access by Pby PNMNMTJTJ

  • 7/28/2019 O&M-PASO NEO-tian

    9/56

    9

    NEC-MIC-0807506 Ver.2.1

    Routine Maintenance

    Metering reading(PNMTJ>performance monitor>meter)

    TX power checkingthe Specification

    +/- 1dBm

    RX level according

    by LOSS design +/-3dBm

    ODU power supplyfollow by IDU power

  • 7/28/2019 O&M-PASO NEO-tian

    10/56

    10

    NEC-MIC-0807506 Ver.2.1

    Note: lower batter will affect your reading!

    Routine Maintenance

    Metering reading on ODU

  • 7/28/2019 O&M-PASO NEO-tian

    11/56

    11

    NEC-MIC-0807506 Ver.2.1

    Routine Maintenance : LinkPerformance Monitor

    11

    Function:To monitor the Link Performance.

    Procedure:Click Performance Monitor---> Link PerformanceMonitor buttonin the NE-specific menu bar.

    (PNMTJ>performancemonitor>link performance monitor)

  • 7/28/2019 O&M-PASO NEO-tian

    12/56

    12

    NEC-MIC-0807506 Ver.2.1

    2. Trouble shooting

    For the basic troubleshooting, following

    method is needed to know by engineer.

    Alarm status checking

    Loop back

    BER measurement

    Troubleshooting Flow

  • 7/28/2019 O&M-PASO NEO-tian

    13/56

    13

    NEC-MIC-0807506 Ver.2.1

    2. Trouble shooting

    LED alarm situation

    ODU Rx=? ODU Tx=?

    Order wire test

    DC power supply

    Following items should pay attention

    during troubleshooting

  • 7/28/2019 O&M-PASO NEO-tian

    14/56

    14

    NEC-MIC-0807506 Ver.2.1

    Trouble shooting

    -alarm checking

    Alarm checking by NMS

    Alarm checking by LED of IDU

    How to check the alarm of one link?

    Basic method is check the alarm first,the microwave equipment has alarmsystem to instruct

  • 7/28/2019 O&M-PASO NEO-tian

    15/56

    15

    NEC-MIC-0807506 Ver.2.1

    Trouble shooting-alarm checking on PNMTJ

  • 7/28/2019 O&M-PASO NEO-tian

    16/56

    16

    NEC-MIC-0807506 Ver.2.1

    Trouble shooting-Alarm checking by PNMSJ&PNMTJ

    Alarm checking can use NMS by software

    PNMSJ (remote checking) or PNMTJ (localchecking).

    Managed Di gi t al Radi oManaged Di gi t al Radi o

    Net wor kNet wor k

    Remote Client Access

    adminadmin

    demodemo

    Filtered TrapsFiltered Traps

    UpperUpperNMSNMS

    Remote accessRemote access by Pby PNMSNMSJJ Local accessLocal access by Pby PNMNMTJTJ

  • 7/28/2019 O&M-PASO NEO-tian

    17/56

    17

    NEC-MIC-0807506 Ver.2.1

    Routine Maintenance-Alarm Checking by NMS

  • 7/28/2019 O&M-PASO NEO-tian

    18/56

    18

    NEC-MIC-0807506 Ver.2.1

    Routine Maintenance-Alarm Checking by LCT

    1. The normal status is in PNMSJ& PNMTJ system is all theboard is green.

    2. The correlation block of the structure figure of mainwindow will change green into red when theequipment occur fault.

    So you need log in PNMTJ to check Alarm:

    (an example as following figure), then you can click on redblock, and check fault information description.

    PC

    (Start)

    PNMSJ&PNMTJ

    (START)

    Alarmboard

    (Click)

    (Show)alarmstatus

  • 7/28/2019 O&M-PASO NEO-tian

    19/56

    19

    NEC-MIC-0807506 Ver.2.1

    Routine Maintenance-ALARM Checking BY PNMTJ

  • 7/28/2019 O&M-PASO NEO-tian

    20/56

    20

    NEC-MIC-0807506 Ver.2.1

    Trouble shooting-Alarm checking on PNMTJ

    Path:

    PNMTJ >EVENT LOG>CLI CK and Checking like upper status

    * Detail Alarm inform checking by Event log interface

  • 7/28/2019 O&M-PASO NEO-tian

    21/56

    21

    NEC-MIC-0807506 Ver.2.1

    NEO 1+0 &NEO/C IDU 1 + 0

    Configuration

    NEO IDU 1 + 1 Configuration

    Trouble shooting-Alarm checking on LED

    Alarm checkingon front of IDULED

  • 7/28/2019 O&M-PASO NEO-tian

    22/56

    22

    NEC-MIC-0807506 Ver.2.1

    Routine Maintenance-Alarm checking by IDU LED

    CTRL Module LED

    IDU

  • 7/28/2019 O&M-PASO NEO-tian

    23/56

    23

    NEC-MIC-0807506 Ver.2.1

    Routine Maintenance-Alarm checking by IDU LED

    Modem Module LED

    IDU

  • 7/28/2019 O&M-PASO NEO-tian

    24/56

    24

    NEC-MIC-0807506 Ver.2.1

    Trouble shooting-loop back by PNMTJ

    MAINTENANCE - PDHMAINTENANCE - SDH

  • 7/28/2019 O&M-PASO NEO-tian

    25/56

    25

    NEC-MIC-0807506 Ver.2.1

    25

    Function:To loop back the MUX signal at the IF

    Procedure: (Maintenance mode must beON)Click IF Loop back buttoninMaintenance menu

    Function:To conduct DADE adjustment

    Procedure: (Maintenance mode must be ON)Click DADE Adjust buttonin Maintenancemenu

    Trouble shooting-loop back by PNMTJ

  • 7/28/2019 O&M-PASO NEO-tian

    26/56

    26

    NEC-MIC-0807506 Ver.2.1

    200894 NEC Corporation 2007 26

    Function:To loop back the signal sent from selected

    NE via the INTFCProcedure: (Maintenance mode must beON)Click Main Loopback-1(INTFC)buttonin Maintenance menu

    ForPDH

    ForSDH

    Trouble shooting-loop back by PNMTJ

  • 7/28/2019 O&M-PASO NEO-tian

    27/56

    27

    NEC-MIC-0807506 Ver.2.1

    200894 NEC Corporation 2007 27

    Function:To loop back the signal sent from the opposite NE at

    selected NEProcedure: (Maintenance mode must be ON)Click Main Loopback-2buttonin Maintenancemenu

    ForPDH

    ForSDH

    Trouble shooting-loop back by PNMTJ

  • 7/28/2019 O&M-PASO NEO-tian

    28/56

    28

    NEC-MIC-0807506 Ver.2.1

    PDH- NEAR END / FAR END SDH- NEAR END / FAR END

    Trouble shooting

    -loop back by PNMTJ

  • 7/28/2019 O&M-PASO NEO-tian

    29/56

    29

    NEC-MIC-0807506 Ver.2.1

    Trouble shooting

    - BER measurement

    BER TEST is used for the PDH bit

    error test

    Notes : For the one PDH channel bit error test , the oppositerelate channel need to be done loop back at same time!

  • 7/28/2019 O&M-PASO NEO-tian

    30/56

    30

    NEC-MIC-0807506 Ver.2.1

    SDH analyzer is used in SDH channel

    bit error Test

    Trouble shooting

    - BER measurement

    Notes : For the one SDH channel connect with analyzer to make bit error test ,

    the opposite relate SDH channel need to be done loop back at same time!

    TX/RX

  • 7/28/2019 O&M-PASO NEO-tian

    31/56

    31

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting flow

  • 7/28/2019 O&M-PASO NEO-tian

    32/56

    32

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting Procedure

    On NMS center:

    1, Service quality down2, Check networks through NMS system3, Problem location: MW or BTS?4, For MW problem collect information remotely

    with help of your local maint. staffs.5, Solve problem by your local staffs, or dispatchexpert to site with suitable spares.

    On site:

    1, Check by PNMT, or LCT2, Adjust antenna for antenna moving3, Check IF cable, DC connector for poor installation4, Replace IDU, ODU for hardware problem.

  • 7/28/2019 O&M-PASO NEO-tian

    33/56

    33

    NEC-MIC-0807506 Ver.2.1

    Trouble shooting

    -Fault isolation

  • 7/28/2019 O&M-PASO NEO-tian

    34/56

    34

    NEC-MIC-0807506 Ver.2.1

    Fault equipment changing procedurewhen troubleshooting

    Troubleshooting

    ODU trouble shooting flow

    IDU ODU trouble shooting flow

  • 7/28/2019 O&M-PASO NEO-tian

    35/56

    35

    NEC-MIC-0807506 Ver.2.1

    Start

    IF in put Alarm? IF cable length?

    MOD DEM Alarm IDU

    Change IF Cable

    Change IF Cable

    IF in put Alarm?

    Replace ODUReplace IDU

    APC1 APC2 Alarm?

    Tx POW Alarm? Replace ODU

    MW is OK!

    Freq. setting ? Resetting freq.

    Replace ODU

  • 7/28/2019 O&M-PASO NEO-tian

    36/56

    36

    NEC-MIC-0807506 Ver.2.1

    Start

    APC1 APC2 Alarm? Freq. setting ? Resetting freq.

    Replace ODU

    Rx level alarm? Opposite ODU OK? Opposite ODU fails

    Freq. setting ?

    Rx Level less 1V

    Replace ODU

    Antenna sys problem

    Resetting freq.

    MW OK

  • 7/28/2019 O&M-PASO NEO-tian

    37/56

    37

    NEC-MIC-0807506 Ver.2.1

    Replace IDU

    Replace IDU

    Replace IDU

    Replace IDU

    Replace IDU and ODU

    IF cable connector

    Replace IDU

    TX CPU ALM

    Replace IDU

    Replace IDU

    Replace IDU

    Replace IDU

    MOD ALM

    TX DPU ALM

    TX CLK LOSS

    MUX ALM

    OPR ALM Grounding system or IDU,ODU

    Input ALM IF Cable connector Correct connector

    120, 75 setting Correct Imp setting

    Replace IDU

    Equipment OK

  • 7/28/2019 O&M-PASO NEO-tian

    38/56

    38

    NEC-MIC-0807506 Ver.2.1

  • 7/28/2019 O&M-PASO NEO-tian

    39/56

    39

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / ODU replacement

  • 7/28/2019 O&M-PASO NEO-tian

    40/56

    40

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / ODU Replacement

  • 7/28/2019 O&M-PASO NEO-tian

    41/56

    41

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / ODU Replacement

  • 7/28/2019 O&M-PASO NEO-tian

    42/56

    42

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / Waterproof for ODU

  • 7/28/2019 O&M-PASO NEO-tian

    43/56

    43

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / IDU replace

  • 7/28/2019 O&M-PASO NEO-tian

    44/56

    44

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / IDU Replacement

  • 7/28/2019 O&M-PASO NEO-tian

    45/56

    45

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / IDU Replace

    To replace the MODEM module

  • 7/28/2019 O&M-PASO NEO-tian

    46/56

    46

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement / IDU Replace

    To remove IDU

    To Mount the IDU

    Troubleshooting

  • 7/28/2019 O&M-PASO NEO-tian

    47/56

    47

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement /Fuse Replacement

    T bl h i

  • 7/28/2019 O&M-PASO NEO-tian

    48/56

    48

    NEC-MIC-0807506 Ver.2.1

    Troubleshooting

    -Fault replacement

    1, Prepare correct type of equipment

    2, Turn off DC power before replace IDU and ODU

    3, Check ODU: Tx high always working with Tx low

    4, 7G,8G Paso+ ODU is point freq. unit. Its freq. has tosetting same with printed freq. on ODU

    5, Normal DC supply Paso+: 40 60V; Paso is 20-70V

    Important points for Unit replace-1

    T bl h ti

  • 7/28/2019 O&M-PASO NEO-tian

    49/56

    49

    NEC-MIC-0807506 Ver.2.1

    6, IDU ID setting should same on both side of one link

    7, DEM maybe setting to ON for 7, 8G ODU

    8, Check IF cable impedance: about 100M OHM for open,about 10K OHM with ODU.

    9, Mark damage equipment, send it to NEC on time.

    10,Check installation situation for frequent equipment

    damage on same site.

    Important points for Unit replace-2

    Troubleshooting

    -Fault replacement

    h i

  • 7/28/2019 O&M-PASO NEO-tian

    50/56

    50

    NEC-MIC-0807506 Ver.2.1

    Sebah019 link problem, BTS alarm,

    Check Rx lower -70dBmCheck Opposite Rx level -70dBmTx out put OK

    Problem on antenna system----antenna misallignment ,change the antenna allignment, the service was ok.

    Note:

    Long term Rx down on both site, problem onantenna system, propagation section.

    Short term Rx down on both side problem relative to fading or poor IF cableConnection.

    Trouble shooting-Examples 1

    A: Rx

    -70dBm

    B: Rx

    -70dBm

  • 7/28/2019 O&M-PASO NEO-tian

    51/56

    51

    NEC-MIC-0807506 Ver.2.1

    Case1 Troubleshooting Summary

    After alignment again the MW link wasok, the BTS signal was normal.

    Result4.

    Step by step to insulate the problem,and then concentrate the problem wasAntenna miss alignment ;

    Measure3.

    a. One side fault?

    b. Water influence ?

    c. ODU lightning strike ?d. Antenna ?

    Analysis2.

    BTS service down, MW link is off; twoside ODU alarm.

    phenomena1.

  • 7/28/2019 O&M-PASO NEO-tian

    52/56

    52NEC-MIC-0807506 Ver.2.1

    Trouble shooting

    -Examples 2

    Eajadabia link problem

    Check Rx lower ***dBmCheck Opposite Rx level -34dBm

    Problem on ODU!--------replace ODU with spares

    Note:

    One site Rx down, problem on ODU.

    A: Rx***dBm

    B: Rx

    -34dBm

  • 7/28/2019 O&M-PASO NEO-tian

    53/56

    53NEC-MIC-0807506 Ver.2.1

    Case2 Troubleshooting Summary

    After change to new ODU (same bandwith same sub-band) , MW link was ok,the BTS signal was normal.

    Result4.

    Step by step to insulate the problem,

    and then concentrate the problem wasODU problem ;

    Measure3.

    a. Configuration problem?

    b. Water influence ?

    c. A side IF cable normal ?d. ODU lightning strike ?

    Analysis2.

    BTS service down, MW link is off; the Aside ODU alarm ,IDU alarm.

    phenomena1.

  • 7/28/2019 O&M-PASO NEO-tian

    54/56

    54NEC-MIC-0807506 Ver.2.1

    Maintenance summary

    1, poor operation situationTemperature over equipment specification, water damage,Lighting damage by poor grounding system, DC powersupply problem, new building affection etc.

    2, poor installationpoor Antenna fix, poor IF cable connector assembly, E1 cableshort circuit or opening, IF connector short circuit etc.

    3, Un suitable transportation

    Maintenance activity include Routine maintenance andtroubleshooting. Alarm checking is very important

    operation in maintenance, after checking Alarm, we cananalysis when kind of trouble system possible have.

    For troubleshooting follow thing need careful beforeinstallation.

  • 7/28/2019 O&M-PASO NEO-tian

    55/56

    55NEC-MIC-0807506 Ver.2.1

    Question &Answer 1 How to check the alarm?

    check the IDU or check the PNMTJ.

    2 How to trouble shooting the link?check the IDU indicator or check the PNMTJ alarm pannel.

    3 How to check the link performance?remote connect PNMSJ or local connect the PNMTJ software to IDU, click themanus of performance monitor>link performance monitor> check the link

    performance by PNMTJ software. The error data should be 0.

    4 How to connect the link status by PNMTJ?local connect the PC to one of the IDU of one link , then start the PNMTJ software.

    5 How to remote control IDU?check the IDU through network by the PNMSJ.