185
TENDER AND CONTRACT DOCUMENT Name of Work:-“Construction and Development of Agri Food Cluster Campus of National Agri Food Biotechnology Institute (NABI) at Mohali (Punjab)” Tender No. : RITES/CP/TC/ROC-II/NABI/Agri Food Cluster Campus/2013 PART 2 FINANCIAL BID SCHEDULE (BILL) OF QUANTITIES

PART 2 FINANCIAL BID SCHEDULE (BILL) OF · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

  • Upload
    dodung

  • View
    219

  • Download
    1

Embed Size (px)

Citation preview

Page 1: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

TENDER AND CONTRACT DOCUMENT

Name of Work:-“Construction and Development of Agri Food Cluster Campus of

National Agri Food Biotechnology Institute (NABI) at Mohali (Punjab)”

Tender No. : RITES/CP/TC/ROC-II/NABI/Agri Food Cluster Campus/2013

PART 2

FINANCIAL BID

SCHEDULE (BILL) OF QUANTITIES

Page 2: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Sch. No.

PARTICULARS Estimated Cost (In Rs.)

Quoted % above/below in Figures & Words

Quoted Amount in Rs.

DSR BASED ITEMS

ACivil Works (Based on DSR-2012)

868052208.67

CElectrical Works (Based on DSR-2012) 23138745.65

EHVAC WORK (Based on DSR-2012)

635997.50MARKET BASED ITEMS

BCivil Works (Based on Market Rate Items)

DElectrical Works (Based on Market Rate Items)

FHVAC WORK (Based on Market Rate Items)

Total amount

Un conditional Rebate if any

Amount after rebate in figure

Amount after rebate in Words

Name of the work :Construction and Development of Agri-Food Cluster Campus of National Agri Food Biotechnology Institute(NABI) at Mohali(Punjab).

ABSTRACT SHEET

Tender No.:RITES/CP/TC/ROC-II/NABI/Agri Food Cluster Campus/2013

Page 3: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

1.00 CARRIAGE OF EARTH

1.1 1.01 Carriage of materials by mechanical transport including loading,unloading and stacking - for 5km.

1.1.2 a Earth Cum 14,093.22 125.92 1,774,618.26

2.00 EARTH WORK

2.31 2.01 Clearing jungle including uprooting of rank vegetation, grass,brush wood, trees and saplings of girth up to 30 cm measured at aheight of 1 m above ground level and removal of rubbish up to adistance of 50 m outside the periphery of the area cleared. 100 Sqm 119.83 482.00 57,758.06

2.8 2.02 Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means in foundation trenches or drains (notexceeding 1.5 m in width or 10 sqm on plan) including dressing ofsides and ramming of bottoms, lift up to 1.5 m, including gettingout the excavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m.

2.8.1 a All kinds of soil. Cum 566.94 130.80 74,155.75

2.7 2.03 Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means over areas (exceeding 30 cm indepth, 1.5m in width as well as 10 sqm on plan) includingdisposal of excavated earth, lead up to 50 m and lift up to 1.5m,disposed earth to be levelled and neatly dressed.

2.7.1 a Ordinary rock Cum 710.45 197.75 140,491.49

2.6 2.04 Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means over areas (exceeding 30cm in depth.1.5 m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m and lift upto 1.5m, disposed earthto be levelled and neatly dressed.

2.6.1 a All kinds of soil Cum 42,508.65 129.35 5,498,621.40

2.10 2.05 Excavating trenches of required width for pipes, cables, etcincluding excavation for sockets, and dressing of sides, rammingof bottoms, depth up to 1.5 m including getting out the excavatedsoil, and then returning the soil as required, inlayers notexceeding 20 cm in depth, including consolidating each depositedlayer by ramming, watering, etc. and disposing of surplusexcavated soil as directed, within a lead of 50 m :

2.10.1 a All kinds of soil

2.10.1.1 ai Pipes, cables etc, not exceeding 80 mm dia. metre 709.20 101.40 71,912.88

2.10.1.2 aii Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. metre 1,296.26 165.60 214,660.66

2.10.1.3 aiii Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. metre 575.19 258.55 148,715.37

2.11 2.06 Extra for excavating trenches for pipes, cables etc. in all kinds ofsoil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate isover corresponding basic item for depth up to 1.5 metre). metre 1,617.08 136.89 221,362.08

2.12 2.07 Extra for excavating trenches for pipes, cables, etc, in all kinds ofsoil for depth exceeding 3 m in depth, but not exceeding 4.5 m.(Rate is over corresponding basic item for depth up to 1.5 metre). metre 1,246.85 351.86 438,714.15

2.16 2.08 Close timbering in trenches including strutting, shoring andpacking cavities (wherever required) complete. Measurements tobe taken of the face area timbered.

2.16.1 a Depth not exceeding 1.5 m. Sqm 1,400.61 101.85 142,652.13

Name of the work :Construction and Development of Agri-Food Cluster Campus of National Agri Food Biotechnology Institute(NABI) at Mohali(Punjab).

DSR SCHEDULE ITEMS(CIVIL) SCHEDULE-A

Page 4: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

2.16.2 b Depth exceeding 1.5 m but not exceeding 3 m. Sqm 1,608.51 106.20 170,823.76

2.16.3 c Depth exceeding 3 m but not exceeding 4.5 m. Sqm 929.54 115.95 107,780.16

2.17 2.09 Close timbering in case of shafts, wells, cesspits, manholes andthe like including strutting, shoring and packing cavities(wherever required) etc. complete.(Measurements to be taken ofthe face area timbered).

2.17.1 a Depth not exceeding 1.5 m. Sqm 1,391.81 104.90 146,000.87

2.17.2 b Depth exceeding 1.5 m but not exceeding 3 m. Sqm 1,460.61 114.15 166,728.63

2.17.3 c Depth exceeding 3 m but not exceeding 4.5 m. Sqm 1,061.54 123.85 131,471.73

2.24 2.10 Extra rates for quantities of works, executed:

2.24.1 a In or under water and/or liquid mud, including pumping out wateras required. Metre Depth 875.92 70.37 61,639.89

2.24.2 b In or under foul position, including pumping out water as required. Metre Depth 729.62 87.96 64,180.66

2.25 2.11 Filling available excavated earth (excluding rock) in trenches,plinth, sides of foundations etc. in layers not exceeding 20cm indepth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift up to 1.5 m.

Cum 22,231.32 83.80 1,862,984.62

2.27 2.12 Supplying and filling in plinth with Jamuna sand under floors,including watering, ramming, consolidating and dressingcomplete. Cum 3,446.68 749.30 2,582,597.32

2.3 2.13 Banking excavated earth in layers not exceeding 20 cm in depth,breaking clods, watering, rolling each layer with ½ tonne roller, orwooden or steel rammers, and rolling every 3rd and top-mostlayer with power roller of minimum 8 tonnes and dressing up, inembankments for roads, flood banks, marginal banks, and guidebanks etc., lead upto 50 m and lift upto 1.5 m :

2.3.1 a All kinds of soil Cum 40,118.83 181.25 7,271,537.94

2.33 2.14 Felling trees of the girth (measured at a height of 1 m aboveground level) including cutting of trunks and branches, removingthe roots and stacking of serviceable material and disposal ofunserviceable material.

2.33.1 a Beyond 30 cm girth up to and including 60 cm girth Each 66.00 148.20 9,781.20

2.33.2 b Beyond 60 cm girth up to and including 120 cm girth Each 63.00 654.95 41,261.85

2.33.3 c Beyond 120 cm girth up to and including 240 cm girth Each 35.00 3,026.30 105,920.50

2.33.4 d Above 240 cm girth Each 26.00 6,071.30 157,853.80

2.34 2.15 Supplying chemical emulsion in sealed containers includingdelivery as specified.

2.34.1 a Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 11,189.75 185.95 2,080,734.01

2.35 2.16 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost ofchemical emulsion) :

2.35.1 a Along external wall where the apron is not provided usingchemical emulsion @ 7.5 litres/ sqm of the vertical surface of thesubstructure to a depth of 300 mm including excavation channelalong the wall & rodding etc. complete:

2.35.1.1 ai With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 1,270.30 11.80 14,989.54

2.38 2.17 Filling with available fly ash and earth (excluding rock) intrenches or embankment in layers (each layer should not exceed15 cm), with intermediate layer of compacted earth (Soil densityof 98%) after every four layers of compacted depth of fly ash,sides & top layer of filling shall be done with earth having totalminimum compacted thickness 30 cm or as decided by Engineer -in- charge, including compacting each layer by rolling/ rammingand watering , all complete as per drawing and direction ofEngineer -in - charge.

Cum 3,950.49 83.80 331,051.06

3.00 CONCRETE WORK

Page 5: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

4.1 3.01 Providing and laying in position cement concrete of specifiedgrade excluding the cost of centering and shuttering - All work upto plinth level :

4.1.3 a 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). Cum 521.52 4,514.05 2,354,167.36

4.1.8 b 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate40mm nominal size). Cum 1,723.65 3,593.30 6,193,591.55

4.5 3.02 Providing and fixing up to floor five level precast cement concretestring or lacing courses, copings, bed plates, anchor blocks, plainwindow sills, shelves, louvers, steps, stair cases, etc. includinghoisting and setting in position with cement mortar 1:3 (1 Cement: 3 coarse sand), cost of required centering complete.

4.5.1 a 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20mm nominal size). Cum 258.13 5,525.20 1,426,219.88

4.12 3.03 Extra for providing and mixing water proofing material in cementconcrete work in doses by weight of cement as per manufacturer’sspecifications.

Per 50KG Cement

7,514.27 35.35 265,629.44

4.17 3.04 Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mmnominal size) over 75mm thick bed of dry brick ballast 40 mmnominal size, well rammed and consolidated and grouted with finesand including finishing the top smooth.

Sqm 1,408.35 338.75 477,078.56

4.00 REINFORCED CEMENT CONCRETE WORK

5.1 4.01 Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level.

5.1.1 a 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20mm nominal size). Cum 405.71 6,333.40 2,569,523.71

5.1.2 b 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size). Cum 81.60 5,094.85 415,739.76

5.9 4.02 Centering and shuttering including strutting, propping etc. andremoval of form for :

5.9.1 a Foundations, footings, bases of columns, etc. for mass concrete. Sqm 32,443.17 166.90 5,414,765.07

5.9.2 b Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc. Sqm 17,248.69 285.15 4,918,463.95

5.9.3 c Suspended floors, roofs, landings, balconies and access platform. Sqm 41,039.80 311.20 12,771,585.76

5.9.5 d Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 26,165.63 262.25 6,861,936.47

5.9.6 e Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 18,097.71 365.60 6,616,522.78

5.9.7 f Stairs, (excluding landings) except spiral-staircases. Sqm 1,900.97 326.30 620,286.51

5.9.14 g Extra for shuttering in circular work (20% of respective centeringand shuttering items). Sqm 1,597.29 57.03 91,093.45

5.10 4.03 Providing and fixing tie bolt, spring coil and plastic cone in wallshuttering complete as per the direction of Engineer-in-charge.

5.10.1 a 12 mm dia. & 100 mm length. Each Set 425.00 125.95 53,528.75 5.10.2 b 12 mm dia. & 150 mm length. Each Set 345.00 139.85 48,248.25 5.10.3 c 20 mm dia. & 150 mm length. Each Set 475.00 153.80 73,055.00 5.10.4 d 20 mm dia.& 225 mm length. Each Set 315.00 174.70 55,030.50 5.11 4.04 Extra for additional height in centering, shuttering where ever

required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m,for every additional height of 1 metre or part thereof (Plan area tobe measured).

5.11.1 a Suspended floors, roofs, landing, beams and balconies (Plan areato be measured). Sqm 21,320.48 121.65 2,593,636.39

Page 6: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

5.18 4.05 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 6mm nominal size) reinforcedwith 1.6 mm dia mild steel wire including centering andshuttering, roughening cleaning, fixing and finishing in cementmortar 1:3 (1 cement: 3 fine sand) etc. complete excludingplastering of the jambs, sills and soffits.

5.18.1 a 50 mm thick. Sqm 1,312.13 598.15 784,850.56

5.22 4.06 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete uptoplinth level.

5.22.6 a Thermo-Mechanically Treated bars. Kg 1,144,927.36 62.25 71,271,728.16

5.22 A 4.07 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all completeabove plinth level.

5.22.6 a Thermo-Mechanically Treated bars. Kg 1,860,243.33 62.25 115,800,147.29

5.30 4.08 Add for plaster drip course/ groove in plastered surface ormoulding to R.C.C. projections. metre 8,118.62 22.25 180,639.30

5.33 4.09 Providing and laying in position machine batched and machinemixed design mix M-25 grade cement concrete for reinforcedcement concrete work, using cement content as per approveddesign mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing andreinforcement, including admixtures in recommended proportionsas per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability as perdirection of Engineer-in-charge. (Note :- cement contentconsidered in this item is @ 330 kg/cum. Excess/less cement usedas per design mix is payable/recoverable separately).

5.33.1 a All works upto plinth level Cum 10,467.82 5,242.15 54,873,882.61

5.33.2 b All works above plinth level upto floor V level Cum 14,210.25 5,781.50 82,156,560.38

5.34 4.10 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content usedis payable /recoverable separately.

5.34.1 a Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note:- Cement content considered in M-30 is @ 340 kg/cum)

Cum 2,491.93 63.20 157,489.98

5.35 4.11 Add for using extra cement in the items of design mix over andabove the specified cement content therein. Quintal 176.15 589.80 103,893.27

5.38 4.12 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for eachfour floors or part thereof. Cum 2,701.99 151.00 408,000.49

Page 7: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

5.44.2 a Floor Joint of 150 mm gap metre 497.93 6,998.60 3,484,812.90

DSR Supplementary 5.45

4.14 Providing and fixing of expansion joint system related with walljoint (internal/external) location as per drawings and direction ofEngineer-In- Charge. The joints shall be of extruded aluminumbase members, self aligning / centering arrangement and supportplates as per ASTM B221-02. The material shall be such that itprovides an Expansion Joints System suitable for vertical wall towall/ wall to corner application, both new and existingconstruction in office Buildings & complexes with no slipping downtendency amongst the components of the Joint System. The JointSystem shall utilize light weight aluminum profiles exhibitingminimal exposed aluminum surfaces mechanically snap lockingthe multicellular to facilitate movement. (Material shall confirm toASTM 6063).

5.45.2 a Wall Joint of 150 mm gap. metre 317.40 5,488.65 1,742,097.51

5.00 BRICK WORK

6.1 5.01 Brick work with common burnt clay F.P.S. (non modular) bricks ofclass designation 75 in foundation and plinth in:

6.1.1 a Cement mortar 1:4 (1 cement : 4 coarse sand). Cum 7,973.68 3,508.25 27,973,662.86

6.3 5.02 Brick work with common burnt clay machine moulded perforatedbricks of class designation 12.5 conforming to IS: 2222 insuperstructure above plinth level up to floor five level in cementmortar 1:6 (1 cement : 6 coarse sand) :

6.3.1 a With F.P.S. (non-modular) bricks Cum 100.00 4,593.40 459,340.00

6.4 5.03 Brick work with common burnt clay F.P.S. (non modular) bricks ofclass designation 75 in superstructure above plinth level up tofloor V level in all shapes and sizes in :

6.4.2 a Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 456.84 3,876.15 1,770,780.37

6.5 5.04 Extra for brick work / AAC block masonry / Tile brick masonry insuperstructure above floor V level for each four floors or partthereof by mechanical means. Cum 1,001.24 250.45 250,760.56

6.34 5.05 Brick work with non modular fly ash lime bricks (FALG Bricks)conforming to IS:12894-2002, class designation 10 averagecompressive strength in super structure above plinth level up tofloor V level in :

6.34.2 a Cement mortar 1:6 (1 cement : 6 Coarse sand). Cum 3,681.11 3,978.50 14,645,296.14

DSR Supplementary 5.44

4.13 Providing and fixing of expansion joint system related with floorlocation as per drawings and direction of Engineer-In-Charge. Thejoints system will be of extruded aluminum base members, selfaligning / self centering arrangement and support plates etc. asper ASTM B221-02. The system shall be such that it provides floorto floor / floor to wall expansion control system for various vertical localtion in load application areas that accommodates multidirectional seismic movement without stress to it's components.System shall consist of metal profiles with a universal aluminumbase member designed to accommodate various project conditionsand finish floor treatments. The cover plate shall be designed ofwidth and thickness required to satisfy projects movement andloading requirements and secured to base members by utilizingmanufacturer's pre-engineered self-centering arrangement thatfreely rotates / moves in all directions. The Self -centeringarrangement shall exhibit circular sphere ends that lock and slideinside the corresponding aluminum extrusion cavity to allowfreedom of movement and flexure in all directions includingvertical displacement. Provision of Moisture Barrier Membrane inthe Joint System to have watertight joint is mandatoryrequirement all as per the manufactures design and as approvedby Engineer -in-Charge . (Material shall confirm to ASTM 6063.)

Page 8: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

6.38 5.06 Providing and laying autoclaved aerated cement blocks masonrywith 100 mm thick AAC blocks in super structure above plinthlevel up to floor V level in cement mortar 1:4 (1 cement : 4coarse sand ). The rate includes providing and placing in position2 Nos 8 mm dia M.S. bars at every third course of masonry work. Cum 2,817.27 4,508.30 12,701,098.34

6.45 5.07 Half brick masonry with non modular fly ash lime Gypsum bricks(FALG bricks) class designation 10, conforming to IS : 12894, insuper structure above plinth and upto floor V level.

6.45.2 a Cement mortar 1 : 4 (1 cement : 4 coarse sand). Sqm 7,483.07 503.10 3,764,732.52

6.14 5.08 Extra for half brick masonry in superstructure, above floor V levelfor every four floors or part thereof by mechanical means.

Sqm 2,757.83 22.20 61,223.83

6.00 STONE WORK

7.23 6.01 Stone work (machine cut edges) for wall lining etc. (veneer work)upto 10 metre height, backing filled with a grout of average 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) includingpointing in white cement mortar 1:2 (1 white cement : 2 stonedust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of crampsand pins which shall be paid for separately):

7.23.2 a Red sand stone - Exposed face machine cut and table rubbed withrough backing.

7.23.2.5 ai 30 mm thick. Sqm 4,589.55 2,236.00 10,262,233.80 7.25 6.02 Providing and fixing stainless steel cramps of required size and

shape for anchoring stone wall lining to the backing or securingadjacent stones in stone wall lining in cement mortar 1:2 (1cement : 2 coarse sand), including making the necessary chasesin stone and holes in walls wherever required.

Kg 22,947.76 524.10 12,026,921.02

7.27 6.03 Providing and fixing copper pins 7.5 cm long 6 mm diameter forsecuring adjacent stones in stone wall lining in cement mortar 1:2(1 cement : 2 coarse sand), including making the necessarychases.

Each 18,358.21 27.40 503,014.95

7.00 MARBLE & GRANITE WORK

8.2 7.01 Providing and fixing 18mm thick gang saw cut mirror polishedpremoulded and prepolished) machine cut for kitchen platforms,vanity counters, window sills , facias and similar locations ofrequired size of approved shade, colour and texture laid over20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand)with joints treated with white cement, mixed with matchingpigment, epoxy touch ups, including rubbing, curing, mouldingand polishing to edges to give high gloss finish etc. complete at all levels.

8.2.1 a Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.

8.2.1.1 ai Area of slab upto 0.50 sqm. Sqm 353.22 1,894.75 669,263.60

8.2.1.2 aii Area of slab over 0.50 sqm. Sqm 2,261.18 1,980.10 4,477,362.52

8.2.2 b Granite of any colour and shade. -

8.2.2.1 bi Area of slab upto 0.50 sqm. Sqm 516.13 3,041.15 1,569,628.75

8.2.2.2 bii Area of slab over 0.50 sqm. Sqm 5,064.71 3,083.40 15,616,526.81

8.3 7.02 Providing edge moulding to 18mm thick marble stone counters,Vanities etc. including machine polishing to edge to give highgloss finish etc. complete as per design approved by Engineer-in-Charge.

8.3.1 a Marble work. metre 5,696.71 105.70 602,142.25

8.3.2 b Granite work. metre 7,978.67 178.75 1,426,187.26

Page 9: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

8.4 7.03 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150mm with epoxy resin based adhesive including cleaning etc.complete.

metre 1,786.04 185.80 331,846.23

8.5 7.04 Extra for providing opening of required size & shape for washbasins/ kitchen sink in kitchen platform, vanity counters andsimilar location in marble/Granite/stone work including necessaryholes for pillar taps etc. including moulding, rubbing and polishingof cut edges etc. complete.

Each 604.00 281.10 169,784.40

8.6 7.05 Mirror polishing on marble work/ Granite work/ stone work whereever required to give high gloss finish complete. Sqm 7,629.53 163.10 1,244,376.34

8.8 7.06 Providing and fixing expansion hold fasteners on C.C./R.C.C./Brick masonry surface backing including drilling necessaryholes and the cost of bolt etc complete.

8.8.1 a Wedge expansion type.

8.8.1.1 ai Fastener with threaded dia 6 mm. Each 410.00 22.05 9,040.50

8.8.1.3 aii Fastener with threaded dia 12 mm. Each 399.00 38.95 15,541.05

8.9 7.07 Stone tile (polished) work for wall lining over 12 mm thick bed ofcement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry@ 3.3 kg/sqm including pointing in white cement complete.

8.9.1 a 8mm thick.

8.9.1.1 ai Raj Nagar Plain white marble/ Udaipur green marble/ Zebra blackmarble. Sqm 1,091.18 1,207.90 1,318,036.32

8.9.1.2 aii Granite of any colour and shade. Sqm 317.39 1,606.70 509,950.51

DSR Supplementary 8.12

7.08 Providing and laying flamed finish Granite stone flooring inrequired design and patterns, in linear as well as curvilinearportions of the building all complete as per the architecturaldrawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laidand jointed with cement slurry and pointing with white cementslurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge.

a Flamed finish granite stone slab Jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. Sqm 310.73 2,667.60 828,903.35

8.10 7.09 Providing and fixing stone slab table rubbed, edges rounded andpolished of size 75x50 cm deep and 1.8 cm thick fixed in urinalpartitions by cutting a chase of appropriate width with chasecutter and embedding the stone in the chase with epoxy grout orwith cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.

8.10.2 a Granite Stone of approved shade. Sqm 129.44 2,942.05 380,818.95

8.00 WOOD AND PVC WORK

9.12 8.01 Extra for providing frosted glass panes 4 mm thick instead ofordinary float glass panes 4 mm thick in doors, windows andclerestory window shutters. (Area of opening for glass panesexcluding portion inside rebate shall be measured). Sqm 1,086.77 5.80 6,303.27

9.20 8.02 Providing and fixing ISI marked flush door shutters conforming toIS : 2202 (Part I) decorative type, core of block boardconstruction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.

9.20.2 a 30 mm thick including ISI marked Stainless Steel butt hinges withnecessary screws. Sqm 2714.420 1984.800

5387580.8169.22 8.03 Extra for Providing and fixing flush doors with decorative

veneering instead of non decorative ISI marked flush doorshutters conforming to IS: 2202 (Part I).

0

Page 10: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

9.22.1 a On one side only. Sqm 1014.000 371.700 376903.89.23 8.04 Extra for providing lipping with 2nd class teak wood battens 25

mm minimum depth on all edges of flush door shutters (over allarea of door shutter to be measured). Sqm 2275.030 325.200

739839.7569.70 8.05 Providing and fixing IS : 12817 marked stainless steel butt hinges

with stainless steel screws etc. complete :

9.70.1 a 125 x 64 x 1.90 mm. Each 117.00 57.65 6,745.05

9.70.2 b 100 X 58 X 1.90 mm. Each 62.00 50.60 3,137.20

9.70.3 c 75 x 47 x 1.80 mm. Each 289.00 34.30 9,912.70

9.84 8.06 Providing and fixing aluminium extruded section body tubular typeuniversal hydraulic door closer (having brand logo with ISI, IS :3564, embossed on the body, door weight upto 36 kg to 80 kgand door width from 701 mm to 1000 mm), with double speedadjustment with necessary accessories and screws etc. complete.

Each 553.00 981.75 542,907.75

9.113 8.07 Providing and fixing bright finished 100mm mortice lock with 6levers without pair of handles for aluminium door with necessaryscrews etc complete (Best make of approved quality) as perdirection of Engineer-in-charge. Each 73.00 410.00 29,930.00

9.114 8.08 Providing and fixing magnetic catcher in cupboard / ward robeshutters including fixing with necessary screws etc. complete .

9.114.1 a Triple strip vertical type. Each 83.00 21.90 1,817.70

9.114.2 b Double strip (horizontal type). Each 83.00 18.45 1,531.35

9.132 8.09 Providing and fixing aluminum U beading of required size to Pre-laminated/ flush door shutter including fixing etc. complete as perdirection of Engineer-in-charge. Kg 4,640.99 400.75 1,859,876.74

9.136 8.10 Providing and fixing fire resistant door frame of section 143 x 57mm having built in rebate made out of 16 SWG G.I.sheet (zinccoating not less than 120gm/sqm) duly filled with vermuculitebased concrete mix, suitable for mounting 60 minutes fire rateddoor shutters. The frame is fitted with intumuscent fire seal stripof size 10x4 mm (minimum) alround the frame and fixing withdash fastener of approved size and make, including applying acoat of approved brand fire resistant primer etc. complete as perdirection of Engineer-in-charge(Dash fastener to be paid forseparately).

metre 445.96 1,161.45 517,960.24

9.137 8.11 Providing and fixing 50 mm thick glazed fire resistant doorshutters of 60 minutes fire rating conforming to IS:3614 (Part-II)tested and certified as per laboratory approved by Engineer-in-charge with suitable mounting on doorframe, consisting of verticalstyles, lock rail, top rail 100mm wide, bottom rail200mm wide,made out of 16 SWG G.I.sheet (zinc coating not less than 120gm/sqm duly filled FR insulation material and fixing withnecessary stainless steel ball bearing hinges of approved make,including applying a coat of approved fire resistant primer etc. allcomplete as per direction of Engineer-in charge(pannelling to bepaid for separately).

Sqm 254.72 5,727.20 1,458,832.38

9.138 8.12 Providing and fixing glazing in fire resistant door shutters, fixedpanels, ventilators and partitions etc., with G.I. beading ofappropriate size made out of 20 SWG G.I.sheet (zinc coating notless than 120 gm/sqm sealant, including applying a coat ofapproved fire resistant primer on G.I. beading etc. complete all asper direction of Engineer-in-charge.

9.138.1 a With clear fire resistant glass panes 6mm thick of approved brand,having minimum 60 minutes fire resistance. Sqm 110.40 25,435.15 2,808,040.56

Page 11: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

9.139 8.13 Providing and fixing panic bar / latch (Double point) fitted with asingle body, Trim Latch & Lock on back side of the Panic Latch ofreputed brand and manufacture to be approved by the Engineer-in- charge, all complete.

Each 73.00 5,873.25 428,747.25

9.124.1 a Non decorative finish. Sqm 201.00 2,609.55 524,519.55

9.124.2 b Decorative finish (both side wood grained finish). Sqm 219.00 3,050.90 668,147.10

9.140 8.15 Providing and fixing plain lining with necessary screws/nuts &bolts/ nails, including a coat of approved primer on one face, andfixed on wooden /steel frame work, complete as per direction ofEngineer-incharge (Frame work shall be paid for separately).

9.140.1 a 12mm thick commercial ply conforming to IS : 1328 BWR type Sqm 947.97 861.05 816,249.57

9.00 STEEL WORK

10.1 9.01 Structural steel work in single section, fixed with or withoutconnecting plate, including cutting, hoisting, fixing in position andapplying a primingcoat of approved steel primer all complete.

kg 40,673.42 59.90 2,436,337.86

10.2 9.02 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer allcomplete.

kg 94,759.04 66.50 6,301,476.16

10.25 9.03 Structural steel work welded in built up sections/ framed workincluding cutting, hoisting, fixing in position and applying apriming coat of approved steel primer using structural steel etc. asrequired.

10.25.1 a In stringers, treads, landings etc. of stair cases including use ofchequered plate wherever required, all complete.

kg 60,798.42 67.20 4,085,653.82

10.25.2 b In gartings, frames, guard bar, ladder, railings, brackets, gatesand similar works. kg 148,200.27 77.90 11,544,801.03

10.28 9.04 Providing and fixing stainless steel ( Grade 304) railing made ofHollow tubes, channels, plates, sheets, pipes, angles, clamps etc.,including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessarystainless steel nuts and bolts complete, i/c fixing the railing withnecessary accessories & stainless steel dash fasteners, stainlesssteel bolts etc., of required size, on the top of the floor or the sideof waist slab with suitable arrangement as per approval ofEngineer-in-charge, ( for payment purpose only weight ofstainless steel members shall be considered excluding fixingaccessories such as nuts, bolts, fasteners etc).

Kg 19,691.18 558.00 10,987,678.44

9.124 8.14 Providing and fixing factory made 30 mm thick door shutter madeof solid PVC foam profile. The styles & rails shall be of size 75 mmx 30 mm having wall thickness 5 mm. The styles, top & bottomrails shall have one side wall thickness of 15 mm integrallyextruded on the hinge side of the profile for better screw holdingpower. The styles and rails shall be reinforced with M.S. tubes ofsize 33 mm x 17 mmx 1 mm, painted with primer , all fourcorners of reinforcement to be welded orsealed. Solid PVC extruded bidding (push fit type) will be setinside the styles and the rails with a cavity, to receive single pieceextruded 5 mm PVC sheet as panel. The styles and rails will bemitred cut and joint with the help of PVC solvent cement & selfdriven self tapping screws. Single piece extruded solid PVC lockrail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mmintegrally extruded in the middle of the lock rail & fixed withstyles with the help of PVC solvent cement & self driven selftapping screws of size 100 mm x 8 mm complete as permanufacturer's specifications and direction of Engineer-in-charge.

Page 12: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

10.6 9.05 Supplying and fixing rolling shutters of approved make, made ofrequired size M.S. laths, interlocked together through their entirelength and jointed together at the end by end locks, mounted onspecially designed pipe shaft with brackets, side guides andarrangements for inside and outside locking with push and pulloperation complete, including the cost of providing and fixingnecessary 27.5 cm long wire springs manufactured from hightensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rollingshutters.

10.6.1 a 80 x 1.25 mm M.S. laths with 1.25 mm thick top cover. Sqm 239.90 1,840.85 441,619.92

10.8 9.06 Extra for providing mechanical device chain and crank operation for operating rolling shutters.

10.8.1 a Exceeding 10.00 sqm and upto 16.80 sqm in the area. Sqm 140.00 627.35 87,829.00

10.8.2 b Exceeding 16.80 sqm in area. Sqm 99.90 662.20 66,153.78

10.9 9.07 Extra for providing grilled rolling shutters manufactured out of 8mm dia M.S. bar instead of laths as per design approved byEngineer-in- charge, (area of grill to be measured). Sqm 134.90 261.35 35,256.12

10.17 9.08 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S.bar, bent to shape with hooked ends in R.C.C. slabs or beamsduring laying, including painting the exposed portion of loop, allas per standard design complete. Each 835.00 106.30 88,760.50

10.00 FLOORING

11.4 10.01 52 mm thick cement concrete flooring with concrete hardenertopping, under layer 40 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) and top layer 12mm thick cement hardenerconsisting of mix 1:2 (1 cement hardener mix : 2 graded stoneaggregate 6 mm nominal size) by volume,. hardening compoundmixed @ 2 litre per 50kg of cement or as per manufacturersspecifications. This includes cost of cement slurry, but excludingthe cost of nosing of steps etc. complete.

Sqm 3,087.76 420.55 1,298,557.47

11.6 10.02 Cement plaster skirting (up to 30 cm height) with cement mortar1:3 (1 cement : 3 coarse sand) finished with a floating coat ofneat cement.

11.6.1 a 18 mm thick. Sqm 309.73 258.20 79,972.29

11.8 10.03 Extra for making chequers of approved pattern on cementconcrete floors, steps, landing, pavements etc. Sqm 3,087.76 24.10 74,415.02

11.23 10.04 Marble stone flooring with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with grey cement slurry including rubbingand polishing complete with :

11.23.3 a Agaria White Sqm 286.32 1,993.30 570,721.66

11.23.4 b Black Zebra. Sqm 600.92 1,165.15 700,161.94

11.23.5 c Udaipur green marble Sqm 1,547.59 1,418.95 2,195,952.83

11.24 10.05 Extra for pre finished nosing to treads of steps of marble stone. Sqm 1,548.92 197.75 306,298.93

11.25 10.06 Extra for marble stone flooring in treads of steps and risers usingsingle length up to 2.00 metre . Sqm 1,926.92 230.55 444,251.41

11.26 10.07 Kota stone slab flooring over 20 mm (average) thick base laidover and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab including rubbing and polishingcomplete with base of cement mortar 1 : 4 (1 cement : 4 coarsesand) :

11.26.1 a 25 mm thick. Sqm 2,847.91 945.70 2,693,268.49

Page 13: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

11.27 10.08 Kota stone slabs 20 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1cement 3coarse sand) and jointed with grey cement slurry mixedwith pigment to match the shade of the slabs, including rubbingand polishing complete.

Sqm 1,511.61 954.10 1,442,227.10

11.29 10.09 40 mm thick fine dressed stone flooring over 20 mm (average)thick base of cement mortar 1:5 (1 cement : 5 coarse sand),including pointing with cement mortar 1:2 (1 cement : 2 stonedust) with an admixture of pigment to match the shade of stone.

11.29.1 a Red sand stone. Sqm 1,710.31 538.30 920,659.87

11.30 10.10 40 mm thick rubbed stone flooring over 20 mm (average) thickbase of cement mortar 1:5 (1 cement :5 coarse sand) with joints3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2stone dust) admixed with pigment to match the shade of stoneand pointing with same mortar.

11.30.1 a Red sand stone. Sqm 3,784.00 591.40 2,237,857.60

11.30.2 b White sand stone. Sqm 200.00 610.55 122,110.00

11.31 10.11 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. metre 392.48 52.45 20,585.58

11.32 10.12 Extra for Kota stone/ sand stone in treads of steps and risersusing single length up to 1.05 metre . Sqm 943.25 12.10 11,413.33

11.45 10.13 Providing and laying 500x500x40 mm thick Turf paver (TurfpaveXD) on 150 mm thick sub grade of compacted bed of 20 mm thicknominal size stone aggregate and base course and filling with 150mm thick jamuna sand, including spreading, well ramming,consolidating and finishing smooth etc. all complete as perdirection of Engineer-in-charge.

Sqm 2,109.00 1,651.20 3,482,380.80

11.41 10.14 Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS : 15622, ofapproved make, in all colours and shades, laid on 20mm thickcement mortar 1:4 (1 cement : 4 coarse sand), including groutingthe joints with white cement and matching pigments etc.,complete.

11.41.2 a Size of Tile 600x600 mm. Sqm 17,420.13 1,337.10 23,292,455.82

11.41.4 b Size of Tile 1000x1000 mm. Sqm 2,236.39 2,246.10 5,023,155.58

11.47 10.15 Providing and laying Vitrified tiles in different sizes (thickness tobe specified by the manufacturer), with water absorption less than0.08% and conforming to IS: 15622, of approved brand &manufacturer, in all colours and shade, in skirting, riser of steps,laid with cement based high polymer modified quick set tileadhesive (water based) conforming to IS: 15477, in average 6mm thickness, including grouting of joints (Payment for groutingof joints to be made separately).

11.47.2 a Size of Tile 600x600 mm. Sqm 8,868.55 1,503.90 13,337,412.35

11.48 10.16 Grouting the joints of flooring tiles having joints of 3 mm width,using epoxy grout mix of 0.70 kg of organic coated filler of desiredshade (0.10 kg of hardener and 0.20 kg of resin per kg), includingfilling / grouting and finishing complete as per direction ofEngineer-in-charge.

11.48.2 a Size of Tile 600x600 mm. Sqm 2,189.39 164.10 359,278.90

11.36 10.17 Providing and fixing Ist quality ceramic glazed wall tilesconforming to IS : 15622 (thickness to be specified by themanufacturer ) of approved make in all colours, shades exceptburgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thickbed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm including pointing inwhite cement mixed with pigment of matching shade complete.

Sqm 2,385.73 724.25 1,727,864.95

Page 14: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

11.37 10.18 Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st qualityconforming to IS : 15622 of approved make in colours such asWhite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cementmortar 1:4 (1 Cement : 4Coarse sand), including pointing the joints with white cement andmatching pigment etc, complete.

Sqm 864.74 764.55 661,136.97

Providing and fixing removable raised/false access flooring withsystem and its components of approved make for different plenumheight with possible height adjustment upto 50mm, comprising ofmodular load bearing floor panels supported on G.I. rectangularstinger frame work and G.I. Pedestal etc. all complete, as per thearchitectural drawings,as specified and as directed by Engineer-in-charge consisting of :

(a) Providing at required spacing to form modular framework,pedestals made out of GI tube of thickness minimum 2 mm and25mm outer diameter, fully welded on to the G.I. Base plate ofsize 100mmx100mmx3mm at the bottom of the pedestal tube,G.I. pedestal head of size 75mmx75mmx3.5mm welded with GIfully threaded stud 16mm outer diameter with two GI Check nutsscrewed on the stud for level adjustment upto 50mm, locking andstabilizing the pedestal head in position at the required level. Thepedestals shall be fixed to the subfloor (base) through base plateusing epoxy based adhesive of approved make or the machinescrew with rawl plug.

Providing and fixing removable raised/false access flooring withsystem and its components of approved make for different plenumheight with possible height adjustment upto 50mm, comprising ofmodular load bearing floor panels supported on G.I. rectangularstinger frame work and G.I. Pedestal etc. all complete, as per thearchitectural drawings,as specified and as directed by Engineer-in-charge consisting of :

(b) Stringers system in all steel construction hot dippedgalvanized of rectangular size 570x20x30x0.80mm thick havingholes at both ends for securing the stringers on to the pedestalhead using fully threaded screws ensuring maximum lateralstability in all directions, the grid formed by the pedestal andstringer assembly shall receive the floor panel, this system shallprovide adequate solid, rigid support for access floor panel, thesystem shall provide a minimum clear uninterrupted clearancebetween the bottom of the floor for electrical conduits and wiringetc. all complete as per the architectural drawings, as specifiedand as directed by the Engineer-in-charge.

(c) Providing and fixing Access Floor panel of 600x600x32 mmmedium grade Filled Steel anti static high pressure Lamination of800H grade (FS800H). Access Floor panel shall be steel weldedconstruction with an enclosed bottom pan with uniform pattern of64 hemispherical cones. The top and bottom plates of SteelGauges: top 0.6 mm and bottom 0.7 mm fused spot weldedtogether (minimum 64 welds in each dome and 20 welds alongeach flange). The panel should be Corroresist epoxy coated forlifetime rust protection and cavity formed by the top and bottomplate is filled with Pyrogrip non-combustible Portland cementitiouscore mixed with lightweight foaming compound.

The access floor shall be factory finished with Anti-static HighPressure laminate with Non Warp technology upto 1mm thicknessfor superior adhesion and Surface flatness within 0.75mm.Thepanel is to withstand a Concentrated Load of 363 kgs applied onarea 25mm x 25mm without collapse in the centre of the panelwhich is placed on four steel blocks. The panel will withstand andUniformly Distributed Load (UDL) minimum 1250 kg/sqm and animpact load of 50kg all complete as per the approvedmanufacturers specification and as per the direction of Engineer-incharge. All specification must be printed on the side of the panelto ensure the quality of the product.

11.54.2 a 450 mm Finished Floor Height Sqm 334.98 3,917.75 1,312,367.90

11.00 ROOFING

DSR Supplementary Items No 11.54

10.19

Page 15: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

12.56 11.01 Providing and laying roof insulation with 40 mm thick impervioussprayed, closed cell free Rigid Polyurethane foam over deckinsulation conforming to IS - 12432 Pt. III (density of foam being40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8sqm per litre, laying 400 G polythene sheet over PUF spray andproviding a wearing course of 40 mm thick cement screed 1: 2 : 4(1 cement :2 coarse sand : 4 stone aggregate 20 mm nominalsize) in chequered rough finish, in panels of 2.5 m x 2.5 m andembedding with 24 G wire netting and sealing the joints withpolymerized mastic, all complete as per direction of Engineer-in-Charge.

Sqm 4,337.11 1,077.15 4,671,718.04

12.53 11.02

Sqm 7,493.22 1,566.00 11,734,382.52

12.54.1 a GI Metal Ceiling Clip in plain Beveled edge global white color tilesof size 600x600 and 0.5 mm thick with 25 mm height, made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive)and electro statically polyester powder coated of thickness 60microns (minimum), including factory painted after bending.

Sqm 489.09 1,559.45 762,711.40

12.54.2 b GI Metal Ceiling Clip in plain Beveled edge global white olor tilesof size 600x600 and 0.5 mm thick with 25 mm height, made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive)and 20% perforation area with 1.8 mm dia holes and having NRCof 0.5, electro statically polyester powder coated of thickness 60microns (minimum), including factory painted after bending andperforation.

Sqm 140.00 1,680.30 235,242.00

Providing and Fixing 15 mm thick densified tegular edged ecofriendly light weight calcium silicate false ceiling tiles of approvedtexture spintone/cosmos / Hexa or equivalent of size 595 x 595mm in true horizontal level, suspended on inter locking metal gridof hot dipped galvanised steel sections (galvanising @ 120 gramsper sqm including both side) consisting of main 'T' runner suitablyspaced at joints to get required length and of size 24x38 mmmade from 0.33 mm thick (minimum) sheet, spaced 1200 mmcentre to centre, and cross "T" of size 24x28 mm made out of0.33 mm (Minimum) sheet, 1200 mm long spaced betweenmain'T' at 600 mm centre to centre to fometre a grid of 1200x600mm and secondary cross 'T' of length 600 mm and size 24 x28mm made of 0.33 mm thick (Minimum) sheet to be inter locked atmiddle of the 1200x 600 mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wallangle pre-coated steel of size(24x24X3000 mm made of 0.40 mmthick (minimum) sheet with the help of rawl plugs at 450 mmcentre to centre with 25 mm long dry wall screws @ 230 mminterval and laying 15 mm thick densified edges calicum silicateceiling tiles of approved texture (Spintone / Cosmos/hexa) in thegrid, including, cutting/ making opening for services like diffusers,grills, light fittings, fixtures, smoke detectors etc., whereverrequired. Main 'T' runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mmdia and 50 mm long dash fasteners, 4 mm G.I. adjustable rodswith galvanised steel level clips of size 85 x 30 x 0.8 mm, spacedat 1200 mm centre to centre along main 'T' , bottom exposed with24 mm of all T-sections shall be pre-painted .

12.54 11.03 Providing and fixing GI Clip in Metal Ceiling System of 600x600mm module which includes providing and fixing 'C' wall angle ofsize 20x30x20 mm made of 0.5 mm thick pre painted steel alongthe perimeter of the room with help of nylon sleeves and woodenscrews at 300 mm center to centre, suspending the main C carrierof size 10x38x10 mm made of G.I steel 0.7 mm thick from thesoffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs ofsize 38x12 mm and C carrier suspension clip and main carrierbracket at 1000 mm c/c. Inverted triangle shaped Spring Teehaving height of 24 mm and width of 34 mm made of GI steel0.45 mm thick is then fixed to the main C carrier and in directionperpendicular to it at 600 mm centers with help of suspensionbrackets. Wherever the main C carrier and spring T have to join, Ccarrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clipin tiles into spring 'T' with :

Page 16: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

12.26 11.04 Providing and fixing plain Multipurpose Cement board ( HighPressure steam cured ) as per IS : 14862, with suitable screws forfibre cement board in ceiling etc. complete (frame work to be paidseparately) :

12.26.1 a 6 mm thick cement board. Sqm 2,063.80 395.30 815,820.14

12.28 11.05 Extra for providing and fixing ceiling to curved surfaces in narrowwidths Sqm 652.97 124.05 81,000.93

12.31 11.06 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceilingup to a height of 5 m above floor level, over first class kail woodstrips 25x6 mm with 10 mm gap in between and reinforced withrabbit wire mesh fixed to wooden frame (frame work to be paidseparately) :

12.31.1 a Flat surfaces Sqm 684.45 676.15 462,790.87

12.41 11.07 Providing and fixing on wall face unplasticised-Rigid PVC rainwater pipes conforming to IS:13592 Type A including jointing withseal ring confirming to IS:5382,leaving 10 mm gap for thermalexpansion .(i) Single Socketed pipes.

12.41.1 a 75 mm diameter. metre 1,130.00 124.90 141,137.00

12.41.2 b 110 mm diameter. metre 1,620.00 206.90 335,178.00 12.42 11.08 Providing & fixing wall face unplasticised - PVC moulded

fittings/accessories for unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type-A, including jointing with seal ringconfirming to IS:5382, leaving 10 mm gap for thermal .

12.42.1 a Coupler

12.42.1.1 ai 75 mm each 186.00 97.60 18,153.60

12.42.1.2 aii 110 mm each 128.00 130.25 16,672.00

12.42.5 b Bend 87.5 Degree

12.42.5.1 bi 75 mm bend each 13.00 104.55 1,359.15

12.42.5.2 bii 110 mm bend each 20.00 156.95 3,139.00

12.00 FINISHING

13.16 12.01 6 mm cement plaster of mix :

13.16.1 a 1:3 (1 cement: 3 fine sand). Sqm 21,351.18 101.00 2,156,469.18

13.4 12.02 12 mm cement plaster of mix:

13.4.1 a 1:4 (1 cement: 4 coarse sand). Sqm 25,926.59 132.10 3,424,902.54

13.5 12.03 15 mm cement plaster on rough side of single or half brick wall of mix :

13.5.1 a 1:4 (1 cement: 4 coarse sand). Sqm 32,735.94 153.60 5,028,240.38

13.72 12.04 Washed stone grit plaster on exterior walls height upto 10 metreabove ground level, in two layers, under layer 12 mm cementplaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layerwith scratching tool, applying cement slurry on the under layer @2 Kg of cement per square metre, top layer 15 mm cement plaster1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mmnominal size), in panels with groove all around as per approvedpattern, including scrubbing and washing the top layer withbrushes and water to expose the stone chippings ,complete as perspecification and direction of Engineer-in- charge (payment forproviding grooves shall be made separately).

Sqm 9,537.50 417.35 3,980,475.63

13.73 12.05 Forming groove of uniform size in the top layer of washed stonegrit plaster as per approved pattern using wooden battens, nailedto the under layer, including removal of wooden battens, repair tothe edges of panels and finishing the groove complete as perspecifications and direction of the Engineer-in-charge :

13.73.1 a 15 mm wide and 15 mm deep groove. metre 5,837.61 23.65 138,059.48

13.74 12.06 Extra for washed grit plaster on exterior walls of height more than10 m from ground level for every additional height of 3 m or partthereof.

Sqm 5,524.10 65.85 363,761.99

Page 17: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

13.19 12.07 Rough cast plaster upto 10m height above ground level with amixture of sand and gravel or crushed stone from 6mm to 10mmnominal size, dashed over and including the fresh plaster in twolayers, under layer12mm cement plaster 1:4 (1 cement: 4 coarsesand) and top layer 10mmcement plaster 1:3 (1 cement: 3 finesand) mixed with 10% finely grounded hydrated lime by volumeof cement.

13.19.1 a Ordinary cement finish using ordinary cement. Sqm 1,584.05 315.30 499,450.97

13.22 12.08 Extra for plastering exterior walls of height more than 10 m fromground level for every additional height of 3 m or part thereof. Sqm 1,232.38 28.85 35,554.16

13.23 12.09 Extra for plastering on circular work not exceeding 6 m in radius:

13.23.1 a In one coat. Sqm 50.00 13.65 682.50

13.26 12.10 Providing and applying plaster of paris putty of 2 mm thicknessover plastered surface to prepare the surface even and smoothcomplete.

Sqm 21,802.10 83.80 1,827,015.98

13.37 12.11 White washing with lime to give an even shade:

13.37.1 a New work (three or more coats). Sqm 4,533.77 11.75 53,271.80

13.60 12.12 Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade :

13.60.1 a Two or more coats on new work. Sqm 73,060.75 60.25 4,401,910.19

13.43 12.13 Applying one coat of water thinnable cement primer of approvedbrand and manufacture on wall surface :

13.43.1 a Water thinnable cement primer. Sqm 73,060.75 27.55 2,012,823.66

13.45 12.14 Finishing walls with textured exterior paint of required shade :

13.45.1 a New work (Two or more coats applied @ 3.28 ltr/10 sqm) overand including priming coat of exterior primer applied @2.20kg/10sqm.

Sqm 5,098.61 117.70 600,106.40

13.47 12.15 Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade :

13.47.1 a New work (Two or more coats applied @ 1.43 ltr/ 10 sqm overand including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

Sqm 9,249.68 80.45 744,136.76

13.51 12.16 Painting with silicon & acrylic emulsion based water thinnablesealer of approved brand and manufacture on wet or patchyportion of plastered surfaces:

13.51.2 a Two coats Sqm 180.00 77.85 14,013.00

13.80 12.17 Providing and applying white cement based putty of averagethickness 1 mm, of approved brand and manufacturer, over theplastered wall surface to prepare the surface even and smoothcomplete.

Sqm 54,515.28 76.05 4,145,887.04

13.61 12.18 Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade:

13.61.1 a Two or more coats on new work. Sqm 47,000.00 53.85 2,530,950.00

13.00 DISMENTLING & DEMOLISHING

15.3 13.01 Demolishing R.C.C. work manually/ by mechanical meansincluding stacking of steel bars and disposal of unserviceablematerial within 50 metres lead as per direction of Engineer - in-charge.

cum 80.00 978.95 78,316.00

15.2 13.02 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as perdirection of Engineer - in - charge.

15.2.2 a Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). cum 35.00 413.65 14,477.75

15.7 13.03 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceablematerial within 50 metres lead as per direction of Engineer-in-charge.

15.7.4 a In cement mortar cum 300.00 566.60 169,980.00

Page 18: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

15.12 13.04 Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within 50 metres lead :

15.12.1 a Of area 3 sq. metres and below. Sqm 40.00 101.70 4,068.00

15.12.2 b Of area beyond 3 sq. metres. Sqm 25.00 139.85 3,496.25

15.25 13.05 Dismantling stone slab flooring laid in cement mortar includingstacking of serviceable material and disposal of unserviceablematerial within 50 metres lead. Sqm 180.00 73.70 13,266.00

14.00 ROAD WORK

16.3 14.01 Supplying and stacking at site.

16.3.9 a Good earth. Cum 14,093.22 260.70 3,674,102.45 16.68 14.02 Providing and laying 60mm thick factory made cement concrete

interlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved size,design & shape, laid in required colour and pattern over andincluding 50mm thick compacted bed of coarse sand, filling thejoints with fine sand etc. all complete as per the direction ofEngineer-in-charge.

Sqm 15,718.98 536.65 8,435,590.62

16.69 14.03 Providing and laying at or near ground level factory made kerbstone of M-25 grade cement concrete in position to the requiredline, level and curvature, jointed with cement mortar 1:3 (1cement: 3 coarse sand), including making joints with or withoutgrooves (thickness of joints except at sharp curve shall not tomore than 5mm), including making drainage opening whereverrequired complete etc. as per direction of Engineer-in-charge(length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by Engineer-in-charge).

Cum 1,483.93 5,046.80 7,489,097.92

Supply DSR 2012 Item 16.89

14.04 Providing and laying matt finished vitrified tile of size 300 x 300 x9.8mm having with water absorption less than 0.5% andconfometreing to IS: 15622 of approved make in all colours andshades in for outdoor floors such as footpath, court yard, multimodals location etc., laid on 20mm thick base of cement mortar1:4 (1cement : 4 coarse sand) in all shapes & patterns includinggrouting the joints with white cement mixed with matchingpigments etc. complete as per direction of Engineer-in-Charge.

Sqm 162.00 899.65 145,743.30

Supply DSR 2012 Item No.16.91

14.05 Providing and laying factory made coloured chamfered edgeCement Concrete paver blocks of required strength, thickness &size/shape, made by table vibratory method using PU mould, laidin required colour & pattern over 50mm thick compacted bed offine sand, compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with jamunasand and cutting of paver blocks as per required size and pattern,finishing and sweeping extra sand in footpath, parks, lawns, driveways or light traffic parking etc. complete as per manufacturer'sspecifications & direction of Engineer-in-Charge. 60mm thick C.C.paver block of M-35 grade with approved colour, design & pattern.

Sqm 11,331.00 703.80 7,974,757.80

16.1 14.06 Preparation and consolidation of sub grade with power road rollerof 8 to 12 tonne capacity after excavating earth to an average of22.5 cm depth, dressing to camber and consolidating with roadroller including making good the undulations etc. and re-rollingthe sub grade and disposal of surplus earth with lead upto 50metres.

Sqm 20,607.00 61.25 1,262,178.75

16.2 14.07 Extra for compaction of earth work in embankment underoptimum moisture conditions to give at least 95% of themaximum dry density (proctor density). Cum 3,297.12 7.75 25,552.68

16.3 14.08 Supplying and stacking at site. -

16.3.1 a 90 mm to 45 mm size stone aggregate Cum 985.07 1,010.75 995,659.50

16.3.2 b 63 mm to 45 mm size stone aggregate Cum 811.71 1,100.80 893,530.37

Page 19: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

16.79 14.09 Providing, laying, spreading and compacting graded stoneaggregate (size range 53 mm to 0.075 mm) to wet mix macadam(WMM) specification including premixing the material with waterat OMC in mechanical mix plant, carriage of mixed material bytipper to site, for all leads & lifts, laying in uniform layers withmechanical paver finisher in sub- base / base course on wellprepared surface and compacting with vibratory roller of 8 to 10tonne capacity to achieve the desired density, complete as perspecifications and directions of Engineer-in-Charge.

Cum 5,700.85 1,960.60 11,177,086.51

16.80 14.10 Construction of dry lean cement concrete sub base over aprepared sub-grade with coarse and fine aggregate conforming toIS:383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradationafter blending to be as per specifications, cement content not tobe less than 150 Kg/cum, optimum moisture content to bedetermined during trial length construction, concrete strength notto be less than 10 Mpa at 7 days, mixed in a batching plant,transported to site, for all leads & lifts, laid with a mechanicalpaver, compacting with 8-10 tonne vibratory roller, finishing andcuring etc. complete as per direction of Engineer-incharge.

Cum 2,060.70 2,896.15 5,968,096.31

16.42 14.11 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 40 mm nominal size) in pavements, laid torequired slope and camber in panels as required includingconsolidation finishing and tamping complete. Cum 1,545.53 4,502.55 6,958,826.10

16.43.1 a Cement concrete prepared with batch mixing machine Cum 2,060.70 5,619.50 11,580,103.65

16.44 14.13 Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete. Litre 4,121.40 43.00 177,220.20

16.45 14.14 Providing and fixing in position pre-moulded joint filler in expansion joints.

per cmdepth percm width

per m length

19,200.00 2.40 46,080.00

16.46 14.15 Providing and laying in position bitumen hot sealing compound for expansion joints etc.

per cmdepth percm width

per m length

16.46.1 a Using grade 'A' sealing compound. 19,200.00 1.65 31,680.00

16.47 14.16 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete.

16.47.1 a New work (Two or more coats). Sqm 1,030.35 94.90 97,780.22

16.43 14.12 Providing and laying design mix cement concrete of M-30 grade,in roads/ taxi tracks/ runways, using cement content as perdesign mix, using coarse sand and graded stone aggregate of 40mm nominal size in appropriate proportions as per approved &specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compactingmechanically by using needle and surface vibrators, levelling torequired slope/ camber, finishing with required texture, includingsteel form work with sturdy M.S. channel sections, curing, makingprovision for contraction/ expansion, construction & longitudinaljoints ( 10 mm wide x 50 mm deep) by groove cutting machine,providing and filling joints with approved joint filler and sealants,complete all as per direction of Engineer-in-charge (Item of jointfillers, sealants, dowel bars with sleeve/ tie bars to be paidseparately).Note:- Cement content considered in M-30 is @ 340 kg/cum.Excess/ less cement used as per design mix is payable/recoverable separately.

Page 20: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

16.60

16.60.1 a Overhead informatory road signage Sqm 84.00 4,516.50 379,386.00

16.62 14.18 Providing and applying 2.5 mm thick road marking strips(retroreflective) of specified shade/ colour using hot thermoplasticmaterial by fully/ semi automatic thermoplastic paint applicatormachine fitted with profile shoe, glass beads dispenser, propanetank heater and profile shoe heater, driven by experiencedoperator on road surface including cost of material, labour ,T&P,cleaning the road surface of all dirt, seals, oil, grease and foreignmaterial etc. complete as per direction of Engineer-in-charge andaccordance with applicable specifications.

Sqm 1,030.35 505.80 521,151.03

16.65 14.19 Providing and fixing post delineators made of ABS round bodyfitted with 2 nos 100 mm dia high reflective reflectors andmounted on MS pipe of 65 mm dia duly powder coated anti-rustand anti theft steel to be installed as per direction of Engineer-in-charge.

Each 10.00 562.55 5,625.50

15.00 SANITARY INSTALLATION

17.31 15.01 Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete.

each 103.00 674.05 69,427.15

17.32 15.02 Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame ofapproved make and shade with 6 mm thick hard board backing :

17.32.3 a Oval shape 450x350 mm (outer dimensions). each 24.00 642.80 15,427.20

17.32.4 b Rectangular shape 1500x450 mm. each 65.00 1,211.00 78,715.00

17.10 15.03 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sinkas per IS : 13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting andmaking goodthe walls wherever required :

17.10.1 a Kitchen sink with drain board.

17.10.1.1 ai 510x1040 mm bowl depth 250 mm. each 58.00 6,743.55 391,125.90

17.10.2 b Kitchen sink without drain board.

17.10.2.2 bi 610 X 460 MM bowl depth 200mm. each 10.00 3,702.00 37,020.00

17.70 15.04 Providing and fixing PTMT Bottle Trap for Wash basin and sink.

17.70.2 a Bottle trap 38 mm single piece moulded with height of 270 mm,effective length of tail pipe 260 mm from the centre of the wastecoupling, 77 mm breadth with 25 mm minimum water seal,weighing not less than 263 gms. each 68.00 435.80 29,634.40

17.35 15.05 Providing and fixing soil, waste and vent pipes:

14.17 Manufacturing, supplying and fixing retro reflective overheadsignage boards made up of 2 mm thick aluminium sheet, face tobe fully covered with high intensity and encapsulated lens typeheat activated retro reflective sheeting conforming to type - III ofASTM-D-4956-01 as approved by Engineer-in-charge, letters,borders etc. as per IRC : 67-2001 in silver white with blue colourback ground and with high intensity grade, pasted on substrate bypressure sensitive adhesive backing which shall be activated byapplying pressure conforming to class II of ASTM-D-4956-01 andfixing the same to the plate of structural frame work by means ofsuitable sized aluminium alloys, rivets or bolts & nuts @ 300 mmcentre to centre all along the periphery as well as in two verticalrows along with theft resistant measures, including the cost ofpainting with two or more coats of epoxy paint in grey colour onthe back side of aluminium sheet including appropriate primingcoat. The rate includes the cost of rounding off the corners,lowering down the structural frame work from the gantry, fixingand erecting the same in position all complete as per drawings,specification and direction of the engineer-in-charge. (Structuralframe work including M.S. plate to be provided separately.Rectangular area of the sheet only shall be measured forpayment).

Page 21: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

17.35.2 a 75 mm dia.

17.35.2.2 ai Centrifugally cast (spun) iron socketed pipe as per IS: 3989: metre 1,245.00 744.50 926,902.50

17.35.1 b 100 mm dia.

17.35.1.2 bi Centrifugally cast (spun) iron socket & spigot (S&S) pipe as perIS: 3989: metre 3,995.00 857.30 3,424,913.50

17.65 15.06 Painting sand cast iron / centrifugally acst (spun) iron soil, wastevent pipes and fittings with paint of any colour such as chocolategrey, or buff etc. over a coat of primer (of approved quality) fornew work:

17.65.2 a 75 mm dia. metre 1,245.00 22.00 27,390.00

17.65.1 b 100 mm dia. metre 3,895.00 28.75 111,981.25

17.39 15.07 Providing and fixing plain bend of required degree:

17.39.2 a 75 mm dia.

17.39.2.2 ai Sand cast iron S&S as per IS - 3989. each 205.00 221.95 45,499.75

17.39.1 b 100mm dia.

17.39.1.2 bi Sand cast iron S&S as per IS - 3989. each 1,242.00 296.35 368,066.70

17.43 15.08 Providing and fixing single equal plain junction of required degreewith access door, insersion rubber washer 3 mm thick, bolts andnuts complete. -

17.43.1 a 100x100x100 mm.

17.43.1.2 ai Sand cast iron S&S as per IS - 3989. each 1,140.00 579.75 660,915.00

17.44 15.09 Providing and fixing single equal plain junction of required degree:

17.44.1 a 100x100x100 mm.

17.44.1.2 ai Sand cast iron S&S as per IS - 3989. each 72.00 522.85 37,645.20

17.44.2 b 75x75x75mm.

17.44.2.2 bi Sand cast iron S&S as per IS - 3989. each 40.00 378.75 15,150.00

17.56 15.10 Providing and fixing terminal guard:

17.56.1 a 100 mm.

17.56.1.2 ai Sand cast iron S&S as per IS - 3989. each 116.00 244.10 28,315.60

17.56.2 b 75 mm

17.56.2.2 bi Sand cast iron S&S as per IS - 3989. each 57.00 221.95 12,651.15

17.58 15.11 Providing lead caulked joints to sand cast iron/ centrifugally cast(spun) iron pipes and fittings of diameter:

17.58.1 a 100mm each 1,600.00 207.85 332,560.00

17.58.2 b 75mm each 590.00 176.50 104,135.00 17.59 15.12 Providing and fixing M.S stays and clamps for sand cast iron /

Centrifugally Cast (Spun) Iron Pipes iron pipes of diameter.

17.59.1 a 100 mm dia each 2,175.00 61.70 134,197.50

17.59.2 b 75 mm dia each 800.00 52.35 41,880.00

17.6 15.13 Providing and fixing trap of self cleansing design with screweddown or hinged grating with or without vent arm completeincluding cost of cutting and making good the walls and floors.

17.60.1 a 100 mm inlet and 100 mm outlet.

17.60.1.1 ai Sand cast iron S&S as per IS:3989 each 446.00 801.70 357,558.20

16.00 WATER SUPPLY

Page 22: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

18.8 16.01 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply including allCPVC plain and brass threaded fittings including fixing the pipewith clamps at 1.00 M spacing. This include jointing of pipes &fitting with one step CPVC solvent cement and the cost of cuttingchases and making good the same including testing of jointscomplete as per direction of Engineer in charge.Concealed work including cutting chases and making good thewalls etc.

18.8.1 a 15 mm nominal outer dia pipes metre 3,085.00 219.55 677,311.75

18.8.2 b 20 mm nominal outer dia pipes metre 1,905.00 243.95 464,724.75

18.8.3 c 25 mm nominal outer dia pipes metre 190.00 298.85 56,781.50

18.8.4 d 32 mm nominal outer dia pipes metre 725.00 359.80 260,855.00

18.7 16.02 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply including allCPVC plain and brass threaded fittings including fixing the pipewith clamps at 1.00 M spacing. This include jointing of pipes &fitting with one step CPVC solvent cement and the cost of cuttingchases and making good the same including testing of jointscomplete as per direction of Engineer in charge.Internal work - Exposed on walls.

18.7.1 a 15 mm nominal outer dia pipes metre 40.00 133.95 5,358.00

18.7.2 b 20 mm nominal outer dia pipes metre 40.00 157.15 6,286.00

18.7.3 c 25 mm nominal outer dia pipes metre 40.00 197.90 7,916.00

18.7.4 d 32 mm nominal outer dia pipes metre 40.00 252.65 10,106.00

18.7.5 e 40 mm nominal outer dia pipes metre 45.00 348.25 15,671.25

18.7.6 f 50 mm nominal outer dia pipes metre 135.00 514.35 69,437.25

18.10 16.03 Providing and fixing of GI pipe complete with GI fiitings andclamps, including cutting and making good the wall as perdirection of Engineer in Charge.Internal Work - Exposed on wall

18.10.1 a 15 mm dia nominal bore metre 130.00 161.60 21,008.00

18.10.2 b 20 mm dia nominal bore metre 615.00 188.05 115,650.75

18.10.3 c 25 mm dia nominal bore metre 630.00 243.15 153,184.50

18.10.4 d 32 mm dia nominal bore metre 2,270.00 296.50 673,055.00

18.10.5 e 40 mm dia nominal bore metre 874.00 364.10 318,223.40

18.10.6 f 50 mm dia nominal bore metre 688.00 453.65 312,111.20

18.38 16.04 Painting GI Pipes and fittings with synthetic enamel white paintwith two coats over a ready mixed priming coat, both of approvedquality for new work:

18.38.1 a 15 mm diametre pipe metre 130.00 7.35 955.50

18.38.2 b 20 mm diametre pipe metre 615.00 8.65 5,319.75

18.38.3 c 25 mm diametre pipe metre 630.00 11.40 7,182.00

18.38.4 d 32 mm diametre pipe metre 1,520.00 13.45 20,444.00

18.38.5 e 40 mm diametre pipe metre 730.00 16.00 11,680.00

18.38.6 f 50 mm diametre pipe metre 330.00 18.80 6,204.00

Page 23: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

18.53 16.05 Providing and fixing C.P. brass angle valve for basin mixer andgeyser points of approved quality conforming to IS:8931 a) 15mm nominal bore.

each 996.00 449.35 447,552.60

18.21 16.06 Providing & Fixing uplasticised PVC connection pipe with brassunions:

18.21.1 a 30 cm length.

18.21.1.1 ai 15 mm nominal bore. each 996.00 51.35 51,144.60

18.49 16.07 Providing and fixing C.P. brass bib cock of approved qualityconformingto IS:8931:

18.49.1 a 15 mm nominal bore each 51.00 397.50 20,272.50

18.40 16.08 Painting GI pipes and fittings with two coats of anti-corrosivebitumastic paint of approved quality.

18.40.4 a 32 mm diameter pipe. metre 750.00 7.80 5,850.00

18.40.5 b 40 mm diameter pipe. metre 144.00 8.90 1,281.60

18.40.6 c 50 mm diameter pipe. metre 358.00 10.55 3,776.90

18.12 16.09 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (External work):

18.12.2 a 20 mm nominal bore. metre 1,420.00 161.25 228,975.00

18.12.3 b 25 mm nominal bore. metre 445.00 209.40 93,183.00

18.12.4 c 32 mm nominal bore. metre 65.00 248.55 16,155.75

18.12.5 d 40 mm nominal bore. metre 45.00 294.25 13,241.25

18.12.6 e 50 mm nominal bore. metre 65.00 355.95 23,136.75

18.12.7 f 65 mm nominal bore. metre 45.00 453.55 20,409.75

18.12.8 g 80 mm nominal bore. metre 820.00 573.40 470,188.00

18.13 16.10 Making connection of G.I. distribution branch with G.I. main offollowing sizes by providing and fixing tee, including cutting andthreading the pipe etc. complete :

18.13.1 a 25 to 40 mm nominal bore. Each 10.00 277.35 2,773.50

18.13.2 b 50 to 80 mm nominal bore. Each 20.00 630.15 12,603.00

18.35 16.11 Constructing masonry Chamber 120x120x100 cm inside, in brickwork in cement mortar 1:4 (1 cement : 4 coarse sand) for sluicevalve, with C.I. surface box 100 mm top diameter, 160 mmbottom diameter and 180 mm deep ( inside) with chained lid andRCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) , i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 gradedstone aggregate 40 mm nominal size) and inside plastering withcement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as perstandard design :

18.35.1 a With common burnt clay F.P.S.(non modular) bricks of class designation 75. Each 5.00 12,492.70 62,463.50

18.41 16.12 Providing and filling sand of grading zone V or coarser grade, all-round the G.I. pipes in external work :

18.41.2 a 20 mm nominal bore. metre 1,420.00 55.50 78,810.00

18.41.3 b 25 mm nominal bore. metre 445.00 56.95 25,342.75

18.41.4 c 32 mm nominal bore, metre 65.00 58.45 3,799.25

18.41.5 d 40 mm nominal bore. metre 45.00 59.20 2,664.00

18.41.6 e 50 mm nominal bore. metre 65.00 61.40 3,991.00

18.41.7 f 65 mm nominal bore. metre 45.00 96.95 4,362.75

18.41.8 g 80 mm nominal bore. metre 820.00 99.90 81,918.00

18.41.9 h 100 mm nominal bore. metre 1,570.00 105.80 166,106.00

18.46 16.13 Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (Newwork) : -

Page 24: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

18.46.2 a 20 mm nominal bore. Each 20.00 142.85 2,857.00

18.46.3 b 25 mm nominal bore. Each 20.00 154.45 3,089.00

18.46.4 c 32 mm nominal bore, Each 30.00 189.30 5,679.00

18.46.5 d 40 mm nominal bore. Each 10.00 229.95 2,299.50

18.46.6 e 50 mm nominal bore. Each 20.00 307.70 6,154.00

18.46.7 f 65 mm nominal bore. Each 20.00 551.60 11,032.00

18.46.8 g 80 mm nominal bore. Each 10.00 656.15 6,561.50

18.60 16.14 Providing and fixing enclosed type water meter (bulk type)conformingto IS : 2373 and tested by Municipal Board completewith bolts,nuts, rubber insertions etc. (The tail pieces if requiredwill be paidseparately) :

18.60.1 a 80 mm dia nominal bore. Each 2.00 2,880.60 5,761.20

18.60.2 b 100 mm dia nominal bore. Each 1.00 4,329.20 4,329.20

17.00 DRAINAGE

19.4 17.01 Providing and fixing square-mouth S.W. gully trap class SP-1complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight ofcover to be not less than 4.50 kg and frame to be not less than2.70 kg as per standard design :

19.4.1 a 100 x 100 mm size P type

19.4.1.1 ai With common burnt clay F.P.S. (non modular) bricks of classdesignation 75. Each 30.00 1,258.05 37,741.50

19.6 17.02 Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar inthe proportion of 1:2 (1 cement : 2 fine sand) including testing ofjoints etc. complete :

19.6.2 a 150 mm dia R.C. C. pipe. metre 420.00 254.50 106,890.00

19.6.3 b 250 mm dia R.C. C. pipe. metre 1,205.00 342.45 412,652.25

19.6.4 c 300 mm dia R.C. C. pipe. metre 1,025.00 422.90 433,472.50

19.6.5 d 450 mm dia R.C. C. pipe. metre 400.00 620.85 248,340.00

19.6.6 e 500 mm dia R.C. C. pipe. metre 1,320.00 722.20 953,304.00

19.6.7 f 600 mm dia R.C. C. pipe. metre 340.00 1,084.25 368,645.00

19.6.9 g 800 mm dia R.C. C. pipe. metre 1,250.00 1,415.70 1,769,625.00

19.7 17.03 Constructing brick masonry manhole in cement mortar 1:4 ( 1cement: 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1cement : 2coarse sand : 4 graded stone aggregate 20 mmnominal size),foundation concrete 1:4:8 mix (1 cement : 4coarse sand : 8 gradedstone aggregate 40 mm nominal size),inside plastering 12 mm thickwith cement mortar 1:3 (1 cement :3coarse sand) finished with floating coat of neat cement andmaking channels in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mmnominal size) finishedwith a floating coat of neat cement complete as per standarddesign :

19.7.1 a Inside size 90x80 cm and 45 cm deep including C.I. cover withframe (light duty) 455x610 mm internal dimensions, totalweight of cover and frame to be not less than 38 kg (weight ofcover 23 kg and weight of frame 15 kg) :

19.7.1.1 ai With common burnt clay F.P.S. (non modular) bricks of classdesignation 75. Each 35.00 7,061.70 247,159.50

19.7.2 17.04 Inside size 120x90 cm and 90 cm deep including C.I. cover withframe (medium duty) 500 mm internal diameter, total weightof cover and frame to be not less than 116 kg (weight of cover 58kg and weight of frame 58 kg) :

19.7.2.1 a With common burnt clay F.P.S. (non modular) bricks of class designation 75. Each 45.00 15,223.25 685,046.25

19.8 17.05 Extra depth for manholes

19.8.1 a Size 90x80 cms

Page 25: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

19.8.1.1 ai With common burnt clay F.P.S. (non modular) bricks of class designation 75. metre 25.00 4,061.70 101,542.50

19.8.2 b Size 120x90 cms

19.8.2.1 bi With common burnt clay F.P.S. (non modular) bricks of class designation 75. metre 13.00 4,866.75 63,267.75

19.9 17.06 Constructing brick masonry circular type manhole 0.91 m internaldia at bottom and 0.56m dia at top in cement mortar 1:4 (1cement :4 coarse sand), in side cement plaster 12 mm thick withcement mortar 1:3 (1 cement : 3 coarse sand) finished with afloating coat of neat cement, foundation concrete 1:3:6 mix (1cement : 3 coarse sand : 6 graded stone aggregate 40 mmnominal size), and making necessary channel in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, allcomplete as per standard design :

19.9.1 a 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20grade designation) 560 mm internal diameter conforming to I.S.12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) includingcentering, shuttering all complete. (Excavation, foot rests and12mm thick cement plaster at the external surface shall be paidfor separately) :

19.9.1.1 ai With common burnt clay F.P.S. (non modular) bricks of class designation 75 Each 80.00 7,033.25 562,660.00

19.10 17.07 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91m to 1.67m

19.10.1 a With common burnt clay F.P.S. (non modular) bricks of class designation 75. metre 77.00 3,498.25 269,365.25

19.11 17.08 Constructing brick masonry circular manhole 1.22 m internal diaat bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement:4 coarse sand) inside cement plaster 12 mm thick with cementmortar 1:3 (1 cement : 3 coarse sand) finished with a floatingcoat of neat cement foundation concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) andmaking necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as perstandard design :

19.11.1 a 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :

19.11.1.1 ai With common burnt clay F.P.S. (non modular) bricks of classdesignation 75. Each 142.00 12,969.25 1,841,633.50

19.12 17.09 Extra depth for circular type manhole 1.22 m internal dia (atbottom) beyond 1.68 m to 2.29 m :

19.12.1 a With common burnt clay F.P.S. (non modular) bricks of classdesignation 75. metre 352.00 4,522.30 1,591,849.60

19.13 17.10 Constructing brick masonry circular manhole 1.52 m internal diaat bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cementmortar 1:3 (1 cement : 3 coarse sand) finished with a floatingcoat of neat cement, foundation concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) andmaking necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as perstandard design :

Page 26: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

19.13.1 a 2.30 m deep with SFRC Cover and frame (heavy duty HD-20grade designation) 560 mm internal diameter conforming to I.S.12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) includingcentering, shuttering all complete. (Excavation, foot rests and12 mm thick cement plaster at the external surface shall be paidfor separately) :

19.13.1.1 ai With common burnt clay F.P.S. (non modular) bricks of classdesignation 75 Each 35.00 26,906.05 941,711.75

19.14 17.11 Extra depth for circular type manhole 1.52 m internal dia (atbottom) beyond 2.30 m :

19.14.1 a With common burnt clay F.P.S. (non modular) bricks of classdesignation 75. metre 25.00 10,643.40 266,085.00

19.15 17.12 Providing M.S. foot rests including fixing in manholes with20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) as perstandard design :

19.15.1 a With 20x20 mm square bar. Each 400.00 228.85 91,540.00

19.15.2 b With 20 mm diameter round bar. Each 2,800.00 194.00 543,200.00

19.16 17.13 Providing orange colour safety foot rest of minimum 6 mm thickplastic encapsulated as per IS : 10910, on 12 mm dia steel barconforming to IS : 1786, having minimum cross section as 23mmx25 mm and over all minimum length 263 mm and width as165 mm with minimum 112 mm space between protruded legshaving 2 mm tread on top surface by ribbing or chequeringbesides necessary and adequate anchoring projections on taillength on 138 mm as per standard drawing and suitable towith stand the bend test and chemical resistance test as perspecifications and having manufacture's permanent identificationmark to be visible even after fixing, including fixing inmanholes with 30x20x15 cm cement concrete block 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) complete as per design.

Each 3,200.00 258.70 827,840.00

19.27 17.14 Constructing brick masonry road gully chamber 50x45x60 cm withbricks in cement mortar 1:4 (1 cement : 4 coarse sand) including500x450 mm pre-cast R.C.C. horizontal grating with framecomplete as per standard design :

19.27.1 a With common burnt clay F.P.S. (non modular) bricks of class designation 75. Each 325.00 3,215.00 1,044,875.00

19.18 17.15 Supplying and fixing C.I. cover without frame for manholes :

19.18.2 a 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. Each 5.00 2,624.65 13,123.25

18.00 ALUMINIUM WORK

21.1 18.01 Providing and fixing aluminium work for doors, windows,ventilators and partitions with extruded built up standard tubularsections/ appropriate Z sections and other sections of approvedmake conforming to IS: 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling upthe gaps at junctions, i.e. at top, bottom and sides with requiredEPDM rubber/neoprene gasket etc. Aluminium sections shall besmooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminium snap beadingfor glazing / paneling, C.P. brass/ stainless steel screws, allcomplete as per architectural drawings and the directions ofEngineer-in-charge. (Glazing, paneling and dash fasteners to bepaid for separately) :

21.1.1 a For fixed portion

21.1.1.1 ai Anodised aluminium (anodised transparent or dyed to requiredshade according to IS: 1868, Minimum anodic coating of grade AC15.) Kg 2,118.09 358.30 758,911.65

21.1.1.2 aii Powder coated aluminium (minimum thickness of powder coating50 micron). Kg 72,955.10 387.60 28,277,396.76

Page 27: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

21.1.2 b For shutters of doors, windows & ventilators including providingand fixing hinges/ pivots and making provision for fixing of fittingswherever required including the cost of EPDM rubber/ neoprenegasket required (Fittings shall be paid for separately).

21.1.2.1 bi Anodised aluminium (anodised transparent or dyed to requiredshade according to IS: 1868, Minimum anodic coating of grade AC15). Kg 2,275.68 406.50 925,063.92

21.1.2.2 bii Powder coated aluminium (minimum thickness of powder coating50 micron). Kg 91,565.33 436.35 39,954,531.75

21.18 18.02 Providing and fixing 12 mm thick frameless toughened glass doorshutter of approved brand and manufacture, including providingand fixing top & bottom pivot & spring type fixing arrangementand making necessary holes etc. for fixing required door fittings,all complete as per direction of Engineer-in-charge (Door handle,lock and stopper etc.to be paid separately).

Sqm 155.42 4,430.80 688,634.94

21.3 18.03 Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directionsof engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item):

21.3.2 a With float glass panes of 5.50 mm thickness. Sqm 6,065.63 905.75 5,493,944.37

21.3.3 b With float glass panes of 8 mm thickness. Sqm 718.39 726.90 522,197.69

21.4 18.04 Providing and fixing double action hydraulic floor spring ofapproved brand and manufacture conforming to IS : 6315, havingbrand logo embossed on the body / plate with double springmechanism and door weight upto 125 kg., for doors, includingcost of cutting floors ,embedding in floors as required and makinggood the same matching to the existing floor finishing and coverplates with brass pivot and single piece M.S. sheet outer box withslide plate etc. complete as per the direction of Engineer-in-charge.

21.4.1 a With stainless steel cover plate minimum 1.25 mm thickness. Each 70.00 1,953.10 136,717.00

21.11 18.05 Providing and fixing stainless steel (SS 304 grade) adjustablefriction windows stays of approved quality with necessarystainless steel screws etc. to the side hung windows as perdirection of Engineer-in-charge complete.

21.11.1 a 205 X 19 mm. Each 219.00 205.40 44,982.60

21.11.3 b 355 X 19 mm. Each 57.00 284.40 16,210.80

21.8 18.06 Filling the gap in between aluminium frame & adjacent RCC/Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and directionof Engineer-in-charge complete.

21.8.1 a Upto 5mm depth and 5 mm width. metre 10,014.06 75.10 752,055.91

21.9 18.07 Extra for applying additional anodic coating AC 25 instead of AC15 to aluminium extruded sections.

21.9.1 a For fixed portion. Kg 2,209.86 11.60 25,634.38

21.9.2 b For shutters of doors, windows & ventilators. Kg 2,390.38 11.60 27,728.41

19.00 WATER PROOFING

Page 28: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

22.7 19.01

22.7.1 a With average thickness of 120mm and minimum thickness at khurra as 65 mm. Sqm 7,481.76 786.70 5,885,900.59

20.00 RAIN WATER HARVESTING & TUBEWELLS

24.1 20.01 Boring/drilling bore well of required dia for casing/ strainer pipe,by suitable method prescribed in IS: 2800 (part I), includingcollecting samples from different strata, preparing and submittingstrata chart/bore log, including hire & running charges of allequipments, tools, plants & machineries required for the job, allcomplete as per direction of Engineer -in-charge, upto 90 metredepth below ground level.

24.1.1 a All types of soil

24.1.1.1 ai 300 mm dia metre 360.00 358.95 129,222.00

24.2 20.02 Boring/drilling bore well of required dia for casing/ strainer pipe,by suitable method prescribed in IS: 2800 (part I), includingcollecting samples from different strata, preparing and submittingstrata chart/ bore log, including hire & running charges of allequipments, tools, plants & machineries required for the job, allcomplete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.

24.2.1 a All types of soil

24.2.1.1 ai 300 mm dia metre 240.00 418.75 100,500.00

24.2.1.3 aii 400 mm dia metre 225.00 628.15 141,333.75

24.3 20.03 Supplying, assembling, lowering and fixing in vertical position inbore well, unplasticized PVC medium well casing (CM) pipe ofrequired dia, conforming to IS: 12818, including required hire andlabour charges, fittings & accessories etc. all complete, for alldepths, as per direction of Engineer -in-charge.

24.3.2 a 150 mm nominal size dia metre 600.00 539.20 323,520.00

24.3.3 b 200 mm nominal size dia metre 150.00 975.45 146,317.50

24.4 20.04 Supplying, assembling, lowering and fixing in vertical position inbore well unplasticized PVC medium well screen (RMS) pipes withribs, conforming to IS: 12818, including hire & labour charges,fittings & accessories etc. all complete, for all depths, as perdirection of Engineer-in-charge.

24.4.2 a 150 mm nominal size dia metre 600.00 545.00 327,000.00

Providing and laying integral cement based water proofingtreatment including preparation of surface as required fortreatment of roofs, balconies, terraces etc consisting of followingoperations: a) Applying a slurry coat of neat cement using 2.75kg/sqm. of cement admixed with water proofing compoundconforming to IS. 2645 and approved by Engineer-in-charge overthe RCC slab including adjoining walls upto300mm heightincluding cleaning the surface before treatment. b)Laying brickbats with mortar using broken bricks/brick bats 25 mm to115mmsize with 50% of cement mortar 1:5 (1 cement : 5 coarsesand)admixed with water proofing compound conforming to IS :2645 and approved by Engineer-in-charge over 20 mm thick layerof cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixedwith waterproofing compound conforming to IS : 2645 andapproved by Engineer-in-charge to required slope and treatingsimilarly the adjoining walls upto 300 mm height includingrounding of junctions of walls and slabs c)After two days of propercuring applying a second coat of cement slurry using 2.75kg/ sqmof cement admixed with water proofing compound conforming toIS : 2645 and approved by Engineer-in-charge. d)Finishing thesurface with 20 mm thick jointless cement mortar of mix1:4 (1cement :4 coarse sand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-chargeincluding laying glass fibre cloth of approved quality in top layerof plaster and finally finishing the surface with trowel with neatcement slurry and making pattern of 300x300 mm square 3mmdeep. e) The whole terrace so finished shall be flooded with waterfor a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed andspecified by the Engineer-in-Charge :

Page 29: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

24.4.3 b 200 mm nominal size dia metre 300.00 981.80 294,540.00

24.5 20.05 Supplying, filling, spreading & leveling stone boulders of sizerange 5 cm to 20 cm, in recharge pit, in the required thickness,for all leads & lifts, all complete as per direction of Engineer-in-charge.

cum 96.00 459.05 44,068.80

24.6 20.06 Supplying, filling, spreading & leveling gravels of size range 5 mmto 10 mm, in the recharge pit, over the existing layer of boulders,in equired thickness, for all leads & lifts, all complete as perdirection of Engineer-in-charge cum 96.00 828.45 79,531.20

24.7 20.07 Supplying, filling, spreading & leveling coarse sand of size range1.5 mm to 2 mm in recharge pit, in required thickness over gravellayer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

cum 96.00 799.40 76,742.40

24.8 20.08 Gravel packing in tubewell construction in accordance with IS:4097, including providing gravel fine/ medium/ coarse, in requiredgrading & sizes as per actual requirement, all complete as perdirection of Engineer-in-charge. cum 36.85 842.80 31,057.18

24.9 20.09 Providing and fixing factory made precast RCC perforated draincovers, having concrete of strength not less than M-25, of size1000 x 450x50 mm, reinforced with 8 mm dia four noslongitudinal & 9 nos cross sectional T.M.T. hoop bars, includingproviding 50 mm dia perforations @ 100 to 125 mm c/c, includingproviding edge binding with M.S. flats of size 50 mm x 1.6 mmcomplete, all as per direction of Engineer-in-charge.

each 30.00 897.10 26,913.00

24.10 20.10 Supplying, assembling, lowering and fixing in vertical position inbore well, ERW (Electric Resistance Welded) FE 410 mild steelscrewed and socketed/ plain ended casing pipes of required dia,conforming to IS: 4270, of reputed & approved make, includingpainted with outside surface with two coats of anticorrosive paintof approved brand and manufacture, including required hire &labour charges, fittings & accessories, all complete, for all depths,as per direction of Engineer-in-charge.

24.10.3 a 200 mm nominal size dia having minimum wall thickness 5.40mm metre 150.00 1,555.10 233,265.00

24.11 20.11 Supplying, assembling, lowering and fixing in vertical position inbore well, ERW (Electric Resistance Welded) FE 410 plain slotted(having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming toIS:8110, of reputed and approved make, having wall thicknessnot less than 5.40 mm, including painted with outside surfacewith two coats of anticorrosive bitumestic paint of approved brandand manufacture, including hire & labour charges, fittings &accessories, all complete, for all depths, as per direction ofEngineer -in-charge.

24.11.3 a 200 mm nominal size dia metre 150.00 1,625.30 243,795.00

24.12 20.12 Development of tube well in accordance with IS : 2800 (part I)and IS: 11189, to establish maximum rate of usable water yieldwithout sand content (beyond permissible limit), with requiredcapacity air compressor, running the compressor for required timetill well is fully developed, measuring yield of well by "V" notchmethod or any other approved method, measuring static level &draw down etc. by step draw down method, collecting watersamples & getting tested in approved laboratory, i/c disinfection oftubewell, all complete, including hire & labour charges of aircompressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge.

hour 240.00 549.10 131,784.00

24.13 20.13 Providing and fixing suitable size threaded mild steel cap or spotwelded plate to the top of bore well housing/ casing pipe,removable as per requirement, all complete for borewell of:

24.13.2 a 150 mm dia Each 4.00 182.95 731.80

24.13.3 b 200 mm dia Each 15.00 219.50 3,292.50

24.14 20.14 Providing and fixing M.S. clamp of required dia to the top ofcasing/housing pipe of tubewell as per IS: 2800 (part I), includingnecessary bolts & nuts of required size complete

Page 30: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

S. No.

Description of Items Unit Quantity Rate (Rs.)

Amount (Rs.)

24.14.2 a 150 mm clamp Each 4.00 1,033.10 4,132.40

24.14.3 b 200 mm clamp Each 15.00 1,173.25 17,598.75

24.15 20.15 Providing and fixing Bail plug/ Bottom plug of required dia to thebottom of pipe assembly of tubewell as per IS:2800 (part I).

24.15.2 a 150 mm dia Each 4.00 206.10 824.40

24.15.3 b 200 mm dia Each 15.00 240.95 3,614.25

868052208.67 Total Cost of DSR item(Civil) of Schedule-A

Page 31: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

Sub Head (A): ELECTRICAL WORKS

CIRCUIT CUM POINT WIRING

1.10 1

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRPVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit, with modular switch, modular plate, suitable GI box and earthing thepoint with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc asrequired.

1.10.1 a Group A Point 1,682.00 462.00 777,084.00 1.10.2 b Group B Point 4,855.00 544.00 2,641,120.00

1.11 2

Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductorsingle core cable in surface / recessed medium class PVC conduit, 2 way modularswitch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVCinsulated copper conductor single core cable etc as required.

Point 135.00 710.00 95,850.00

1.18 3Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copperconductor, unarmored telephone cable in the existing surface/ recessed steel/ PVCconduit as required.

1.18.2 a 2 Pair metre 27,999.00 15.50 433,984.50 1.18.3 b 4 Pair metre 664.00 24.00 15,936.00

1.14 4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRPVC insulated copper conductor, single core cable in surface/ recessed medium classPVC conduit as required

1.14.1 a 2 x 1.5 Sq.mm. + 1 x 1.5 Sq.mm. earth wire metre 200.00 107.00 21,400.00 1.14.2 b 2 x 2.5 Sq.mm. + 1 x 2.5 Sq.mm. earth wire metre 5,278.00 131.00 691,418.00 1.14.3 c 2 x 4 Sq.mm. + 1 x 4 Sq.mm. earth wire metre 250.00 162.00 40,500.00 1.14.4 d 2 x 6 Sq.mm. + 1 x 6 Sq.mm. earth wire metre 3,951.00 206.00 813,906.00 1.14.9 e 4 x 6 Sq.mm. + 2 x 6 Sq.mm. earth wire metre 6,941.00 358.00 2,484,878.00 1.14.10 f 4 x 10 Sq.mm. + 2 x 10 Sq.mm. earth wire metre 150.00 562.00 84,300.00

1.19 5Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductorPE insulated, shielded with fine tinned copper braid and protected with PVC sheath inthe existing surface/ recessed steel/ PVC conduit as required.

metre 11,378.00 22.00 250,316.00

1.21 6Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/recess including cutting the wall and making good the same incase of recessed conduit as required.

1.21.1 a 20 mm metre 13,151.00 56.50 743,031.50 1.21.2 b 25 mm metre 22,441.00 64.50 1,447,444.50 1.21.3 c 32 mm metre 700.00 80.50 56,350.00

1.24 7

Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required.

1.24.6 a Telephone Socket Outlet Each 985.00 89.00 87,665.00

Name of the work :Construction and Development of Agri-Food Cluster Campus of National Agri Food Biotechnology Institute(NABI) at Mohali(Punjab).

DSR SCHEDULE ITEMS (ELECTRICAL) SCHEDULE-C

Page 32: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

1.24.7 b TV Antenna Socket Outlet Each 325.00 93.00 30,225.00

Page 33: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

1.25 8Supplying and fixing stepped type electronic fan regulator on the existing modularplate switch box including connections but excluding modular plate etc. as required.

Each 339.00 322.00 109,158.00

1.26 9Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required.

Each 321.00 22.00 7,062.00

1.27 10Supplying and fixing following size/ modules, GI box alongwith modular base & coverplate for modular switches in recess etc as required.

1.27.1 a 1 or 2 Module (75 mm x 75 mm) Each 2,474.00 142.00 351,308.00 1.27.2 b 3 Module (100 mm x 75 mm) Each 958.00 154.00 147,532.00 1.27.3 c 4 Module (125 mm x 75 mm) Each 137.00 173.00 23,701.00 1.27.4 d 6 Module (200 mm x 75 mm) Each 1,686.00 221.00 372,606.00 1.27.5 e 8 Module (125 mm x 125 mm) Each 198.00 255.00 50,490.00 1.27.6 f 12 Module (200 mm x 150 mm) Each 18.00 344.00 6,192.00

1.31 11

Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings).

Each 3,182.00 288.00 916,416.00

1.32 12Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modularsocket outlet and 15/16 amps modular switch, connection etc. as required.

Each 1,241.00 366.00 454,206.00

1.33 13Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required.

Each 329.00 34.00 11,186.00

1.38 14Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete asrequired.

Each 156.00 54.50 8,502.00

1.41 15

Installation, testing and commissioning of pre-wired, fluorescent fitting / compactfluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, singlecore cable and earthing etc. as required.

Each 4,403.00 69.50 306,008.50

1.45 16

Installation, testing and commissioning of ceiling fan, including wiring the down rods ofstandard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable, including providing and fixing phenolic laminated sheet cover on thefan box etc. as required.

Each 339.00 99.00 33,561.00

1.50 17Installation of exhaust fan in the existing opening, including making good the damage,connection, testing, commissioning etc. as required.

1.50.1 a Upto 450 mm Sweep Each 206.00 163.00 33,578.00

1.51 18 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 206.00 68.50 14,111.00

DISTRIBUTION BOARD, MCCB,MCB&RCCB

2.7 19

Supplying and fixing following way prewired SP&N MCB distribution board of steel sheetfor 240 volts on surface/ recess complete with loose wire box, terminal connectors forall incoming and outgoing circuits, duly prewired with suitable size FR PVC insulatedcopper conductor up to terminal blocks, tinnedcopper bus bar, neutral link, earth bar, din bar, detachable gland plate,interconnections, powder painted including earthing etc. as required. (But withoutMCB/ RCCB/ Isolator)

Page 34: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

2.7.4 a 2 + 4 Way, Double Door Each 109.00 2,152.00 234,568.00 2.7.5 b 2 + 8 Way, Double Door Each 22.00 2,572.00 56,584.00 2.7.6 c 2 + 12 Way, Double Door Each 7.00 3,108.00 21,756.00

2.8 20

Supplying and fixing following way prewired TP&N MCB distribution board of steel sheetfor 415 volts on surface/ recess complete with loose wire box, terminal connectors forall incoming and outgoing circuits, duly prewired with suitable size FR PVC insulatedcopper conductor up to terminal blocks, tinnedcopper bus bar, neutral link, earth bar, din bar, detachable gland plate,interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/ Isolator)

2.8.6 a 6 Way (4 + 18), Double Door Each 31.00 8,197.00 254,107.00 2.8.7 b 8 Way (4 + 24), Double Door Each 26.00 8,984.00 233,584.00 2.8.8 c 12 Way (4 + 36), Double Door Each 57.00 11,042.00 629,394.00

2.9 21

Supplying and fixing following way prewired vertical type TP&N MCB distribution boardof steel sheet for 415 volts on surface/ recess complete with loose wire box of sheetsteel, dust protected, duly powder painted, inclusive of 200 amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectorsfor all incoming and outgoing circuits, duly prewired with adequate size of FR PVCinsulated copper conductor upto the terminal connector/ neutral link, earthing etc asrequired (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDBis normally used where 3 phase outlets are required.)

2.9.5 a 4 Way Double Door Each 12.00 6,816.00 81,792.00 2.9.6 b 6 Way Double Door Each 7.00 8,810.00 61,670.00 2.9.7 c 8 Way Double Door Each 6.00 9,606.00 57,636.00 2.9.8 d 12 Way Double Door Each 1.00 12,762.00 12,762.00

2.10 22Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.

2.10.1 a Single Pole Each 4,010.00 141.00 565,410.00 2.10.4 b Triple Pole Each 59.00 562.00 33,158.00

2.11 23Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. asrequired.

Each 516.00 5.50 2,838.00

2.14 24

Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.

2.14.1 a 25 Amps Each 130.00 1,318.00 171,340.00 2.14.2 b 40 Amps Each 180.00 1,394.00 250,920.00

Three Phase Residual Current Circuit Breaker

2.15 25

Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current upto 300milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.

2.15.1 a 25 Amps Each 10.00 1,679.00 16,790.00 2.15.2 b 40 Amps Each 75.00 1,703.00 127,725.00 2.15.3 c 63 Amps Each 41.00 1,965.00 80,565.00

Page 35: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

SPN Industrial Type Socket Outlet

2.18 26

Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 poleand earth, metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheetsteel enclosure, on surface or in recess, with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required.

Each 359.00 693.00 248,787.00

2.19 27

Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 poleand earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheetsteel enclosure, on surface or in recess, with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required

Each 100.00 1,718.00 171,800.00

2.20 28

Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 poleand earth, metal enclosed plug top along with 30 amps "C" curve, TPMCB, in sheetsteel enclosure, on surface or in recess, with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required

Each 20.00 1,983.00 39,660.00

Page 36: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

CABLE TRAYS AND ACESSORIES:

4.1 29

Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required.

4.1.1 a 100 mm width X 50 mm depth X 1.6 mm thickness metre 100.00 405.00 40,500.00 4.1.2 b 150 mm width X 50 mm depth X 1.6 mm thickness metre 404.00 464.00 187,456.00 4.1.4 c 300 mm Width x 50 mm Depth x 1.6 mm Thickness metre 255.00 677.00 172,635.00 4.1.7 d 600 mm Width x 50 mm Depth x 1.6 mm Thickness metre 65.00 1,210.00 78,650.00 4.1.15 e 750 mm width X 75 mm depth X 2.0 mm thickness metre 325.00 1,507.00 489,775.00

EARTHING INSTALLATION

5.4 30

Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

Each 24.00 3,996.00 95,904.00

5.6 31

Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired.

Each 6.00 8,559.00 51,354.00

5.8 32

Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as stripearth electrode, including connection/ terminating with nut, bolt, spring, washer etc. asrequired. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt &spring washer spaced at 50mm)

metre 500.00 680.00 340,000.00

5.9 33

Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as stripearth electrode, including connection/ terminating with G.I. nut, bolt, spring, washeretc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt& spring washer spaced at 50mm)

metre 970.00 97.50 94,575.00

5.10 34Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earthelectrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

metre 60.00 962.00 57,720.00

5.11 35Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earthelectrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

metre 240.00 364.00 87,360.00

5.14 36Providing and fixing 25 mm X 5 mm copper strip on surface or in recess forconnections etc. as required.

metre 300.00 766.00 229,800.00

5.15 37Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connectionsetc. as required.

metre 530.00 120.00 63,600.00

5.18 38Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable s required.

metre 4,478.00 19.50 87,321.00

5.17 39Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required.

metre 300.00 87.50 26,250.00

LIGHTNING CONDUCTOR

6.1 40Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long,copper tube, having single prong at top, with 85 mm dia 3mm thick copper base plateincluding holes etc. complete as required.

Each 22.00 701.00 15,422.00

Page 37: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

6.4 41Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or anyother metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

Each 10.00 60.50 605.00

6.7 42Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall forlightning conductor complete as required.(For horizontal run)

metre 1,445.00 58.00 83,810.00

6.8 43Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall forlightning conductor complete as required.(For vertical run)

metre 1,020.00 81.50 83,130.00

6.12 44Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mmlong, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete asrequired.

Each 20.00 58.50 1,170.00

6.14 45Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in groundas required.

metre 700.00 125.00 87,500.00

Page 38: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

5.4 46Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

Set 34.00 3,996.00 135,864.00

CABLES, MAINS AND SUB MAINS

7.8 47Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on cable tray as required.

7.8.1 a Upto 35 Sq.mm (Clamped with 1 mm thick saddle) metre 5,590.00 16.50 92,235.00 7.8.2 b Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp). metre 880.00 38.50 33,880.00

7.8.3 c Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) metre 710.00 47.50 33,725.00

7.8.4 d Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) metre 22.00 72.50 1,595.00

9.1 48Supplying and making indoor end termination with brass compression gland andaluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required.

9.1.21 a 3½ X 35 sq. mm (32mm) each 38.00 223.00 8,474.00 9.1.22 b 3½ X 50 sq. mm (35mm) each 6.00 262.00 1,572.00 9.1.23 c 3½ X 70 sq. mm (38mm) each 32.00 297.00 9,504.00 9.1.24 d 3½ X 95 sq. mm (45mm) each 14.00 366.00 5,124.00 9.1.25 e 3½ X 120 sq. mm (45mm) each 10.00 383.00 3,830.00 9.1.26 f 3½ X 150 sq. mm (50mm) each 18.00 458.00 8,244.00 9.1.27 g 3½ X 185 sq. mm (57mm) each 16.00 616.00 9,856.00 9.1.30 h 3½ X 300 sq. mm (70mm) each 2.00 867.00 1,734.00 9.1.32 i 4 X 10 sq. mm (25mm) each 120.00 146.00 17,520.00 9.1.33 j 4 X 16 sq. mm (28mm) each 4.00 188.00 752.00 9.1.34 k 4 X 25 sq. mm (28mm) each 24.00 192.00 4,608.00

TOTAL OF SUB HEAD (A) 19,656,926.00 SUB HEAD(B): ELECTRICAL HIGH END EQUIPMENTS & DG SETS (UTILITY-1&2)

HT & LT Cables

7.1 49

Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size direct in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required.

7.1.1 a Upto 35 sq. mm metre 397.50 167.00 66,382.50 7.1.2 b Above 35 sq. mm and upto 95 sq. mm metre 72.60 173.00 12,559.80 7.1.3 c Above 95 sq. mm and upto 185 sq. mm metre 189.00 179.00 33,831.00 7.1.4 d Above 185 sq. mm and upto 400 sq. mm metre 895.80 196.00 175,576.80

7.2 50

Laying of one number additional PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground in the same trench in one tierhorizontal formation including excavation, sand cushioning, protective covering andrefilling the trench etc as required.

7.2.1 a Upto 35 sq. mm metre 662.50 115.00 76,187.50 7.2.2 b Above 35 sq. mm and upto 95 sq. mm metre 121.00 121.00 14,641.00 7.2.3 c Above 95 sq. mm and upto 185 sq. mm metre 315.00 127.00 40,005.00 7.2.4 d Above 185 sq. mm and upto 400 sq. mm metre 1,493.00 144.00 214,992.00

7.5 51Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size in the existing RCC/ HUME/ METAL pipe as required.

Page 39: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

7.5.1 a Upto 35 sq. mm metre 132.50 12.00 1,590.00 7.5.2 b Above 35 sq. mm and upto 95 sq. mm metre 24.20 18.50 447.70 7.5.3 c Above 95 sq. mm and upto 185 sq. mm metre 63.00 25.00 1,575.00 7.5.4 d Above 185 sq. mm and upto 400 sq. mm metre 298.60 44.00 13,138.40

7.8 52Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on cable tray as required.

7.8.1 a Upto 35 sq. mm (clamped with 1mm thick saddle) metre 132.50 16.50 2,186.25

7.8.2 bAbove 35 sq. mm and upto 95 sq. mm (clamped with 25x3mmMS flat clamp)

metre 24.20 38.50 931.70

7.8.3 c Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) metre 63.00 47.50 2,992.50

7.8.4 d Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) metre 289.60 72.50 20,996.00

7.10 53Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. platewith inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cmlong and fixing the same in ground as required.

Each 20.00 244.00 4,880.00

H.T POWER CABLE END TERMINATION

10.4 54Supplying and making indoor cable end termination with heat shrinkable jointing kitcomplete with all accessories includind lugs suitable for following size of 3 core XLPEaluminium conductor cable of 11 kV grade asquired.

10.4.4 a 300 sq. mm Each 16.00 6,881.00 110,096.00 L.T POWER CABLE END TERMINATION

9.1 55

Cable end temetreination of the following PVC insulated sheathed PVC/XLPE aluminium/ copper conductor ametreoured cables of 1100 volt grade including supplying andfixing of crimping aluminium lugs, double compression glands with earthing facility atboth ends of cables etc. complete as required.

9.1.23 a 3.5 core 70 sq.mm each 4.00 297.00 1,188.00 9.1.26 b 3.5 core 150 sq.mm each 12.00 458.00 5,496.00 9.1.29 c 3.5 core 240 sq. mm each 16.00 771.00 12,336.00 9.1.30 d 3.5 core 300 sq.mm each 34.00 867.00 29,478.00 9.1.31 e 3.5 core 400 sq.mm each 8.00 1,109.00 8,872.00 9.1.21 f 3.5 core 35 sq. mm each 2.00 223.00 446.00 9.1.34 g 4 core 25 sq. mm each 20.00 192.00 3,840.00

CABLE TRAYS AND ACESSORIES:

4.1 56

Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required.

4.1.2 a 150 mm width X 50 mm depth X 1.6 mm thickness metre 150.00 464.00 69,600.00 4.1.4 b 300 mm Width x 50 mm Depth x 1.6 mm Thickness metre 400.00 677.00 270,800.00 4.1.15 c 750 mm width X 75 mm depth X 2.0 mm thickness metre 500.00 1,507.00 753,500.00

BATTERY & BATTERY CHARGER

2932 57Providing & fixing HT danger notice plate of 250 mm x 200mm, made of mild steelsheet of minimum 2mm thick & vitreous enamelled white on both sides and withinscription in signal red colour on front side as required.

Each 8.00 47.25 378.00

2933 58Supply & fixing MV danger notice plate of 200 mm x 150mm, made of mild steel sheetof minimum 2mm thick & vitreous enamelled white on both sides and with inscriptionin signal red colour on front side as required.

Each 6.00 36.75 220.50

SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF EXTERNALLIGHTING FIXTURES.

Page 40: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

1.14 59Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRPVC insulated copper conductor, single core cable in surface/ recessed medium classPVC conduit as required

1.14.1 a 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire meter 350.00 107.00 37,450.00 1.14.2 b 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire meter 300.00 131.00 39,300.00 1.14.3 c 2 X 4 sq. mm + 1 X 4 sq. mm earth wire meter 100.00 162.00 16,200.00

7.1 60Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size direct in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required.

7.1.1 a Upto 35 sq. mm metre 120.00 167.00 20,040.00

7.2 61

Laying of one number additional PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground in the same trench in one tierhorizontal formation including excavation, sand cushioning, protective covering andrefilling the trench etc as required.

7.2.1 a Upto 35 sq. mm metre 680.00 115.00 78,200.00 EARTHING INSTALLATION (SUB STATION)

5.4 62

Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

Set 24.00 3,996.00 95,904.00

5.6 63

Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired.

Set 18.00 8,559.00 154,062.00

TOTAL OF SUB HEAD (B) 2,390,319.65 Sub- Head (C): FIRE FIGHTING SYSTEM

1.17 64Supply and drawing following sizes of FR PVC insulated copper conductor, single corecable in the existing surface/recessed steel conduit as required.

1.17.2 a 2X1.5 sqmm metre 7,000.00 33.50 234,500.00

1.20 65Supply and fixing of following sizes of steel conduit along with accessories insurface/recess including painting in case of surface , or cutting the wall and makinggood the same in case of recessed conduit ar required.

1.20.1 a 20mm dia metre 2,000.00 123.00 246,000.00 1.20.2 b 25mm dia metre 4,000.00 143.00 572,000.00 1.20.3 c 32mm dia metre 200.00 195.00 39,000.00

TOTAL OF SUB HEAD(C) 1,091,500.00

Total Cost of DSR items(Electrical) of Schedule-C 23,138,745.65

Page 41: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

DSR Item No.

Sr.No. Description of Items Unit Quantity Rates (Rs.) Amount (Rs.)

DSR SCHEDULE ITEMS (HVAC WORK) SCHEDULE-E

SUB HEAD (A): -LABORATORY

5.18 1Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required.

RM 500.00 19.50 9,750.00

7.8 2Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on cable tray as required.

7.8.1 a Upto 35 Sq.mm (Clamped with 1 mm thick saddle) RM 986.00 16.50 16,269.00 7.8.2 b Above 35 Sq.mm & Upto 95 Sq.mm (Clamped with 25 X 3mm MS Flat Clamp) RM 60.00 38.50 2,310.00

7.8.4 cAbove 185 Sq.mm & Upto 400 Sq.mm (Clamped with 40 X 3mm MS Flat Clamp) RM

35.00 72.50 2,537.50

END TERMINATION OF CABLES

9 3Supplying and making indoor end termination with brass compression gland andaluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required.

9.1.33 a 4 Core 16 Sq.mm. (Copper armoured Cable) No. 28.00 188.00 5,264.00 9.1.34 b 4 Core 25 Sq.mm. (Aluminium armoured Cable) No. 2.00 192.00 384.00 9.2.19 c 3.5 Core 50 Sq.mm. (Aluminium armoured Cable) No. 4.00 601.00 2,404.00 9.2.20 d 3.5 Core 70 Sq.mm. (Aluminium armoured Cable) No. 6.00 664.00 3,984.00 9.2.26 e 3.5 Core 240 Sq.mm. (Aluminium armoured Cable) No. 20.00 1,137.00 22,740.00

CABLE TRAY & ACCESSORIES

4.1 4

Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required.

4.1.7 a 600 mm Width x 50 mm Depth x 2 mm Thickness RM 50.00 1,210.00 60,500.00 4.1.4 b 300 mm Width x 50 mm Depth x 1.6 mm Thickness RM 120.00 677.00 81,240.00 4.1.2 c 150 mm Width x 50 mm Depth x 1.6 mm Thickness RM 810.00 464.00 375,840.00

TOTAL OF SUB HEAD(A) 583,222.50 Sub- Head (B): ANIMAL HOUSE

5.18 5Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit/ submain wiring/ cable as required.

RM 200.00 19.50 3,900.00

7.8 6Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on cable tray as required.

7.8.1 a Upto 35 Sq.mm (Clamped with 1 mm thick saddle) RM 150.00 16.50 2,475.00 CABLE TRAY & ACCESSORIES

4.1 7

Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required.

4.1.1 a 150 mm Width x 50 mm Depth x 1.6 mm Thickness RM 100.00 464.00 46,400.00 TOTAL OF SUB HEAD (B) 52,775.00

Total cost of DSR Items-HVAC WORK of Schedule-E 635,997.50

Page 42: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

EARTH WORK1 Earth work in excavation by mechanical means

(Hydraulic excavator) / manual means over areas(exceeding 30cm in depth. 1.5 m in width as well as10 sqm on plan) including disposal of excavated earth,lead upto 50m and lift from 1.5m to 3m, disposedearth to be levelled and neatly dressed.

a All kinds of soil. Cum 9812.51

2 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means over areas(exceeding 30cm in depth. 1.5 m in width as well as10 sqm on plan) including disposal of excavated earth,lead upto 50m and lift from 3m to 4.5m, disposedearth to be levelled and neatly dressed.

a All kinds of soil. Cum 3533.65

3 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means over areas(exceeding 30cm in depth. 1.5 m in width as well as10 sqm on plan) including disposal of excavated earth,lead upto 50m and lift from 4.5m to 6m, disposedearth to be levelled and neatly dressed.

a All kinds of soil. Cum 2685.93

4 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means over areas(exceeding 30cm in depth. 1.5 m in width as well as10 sqm on plan) including disposal of excavated earth,lead upto 50m and lift from 6m to 7.5m, disposedearth to be levelled and neatly dressed.

a All kinds of soil. Cum 2685.93

5 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means over areas(exceeding 30cm in depth. 1.5 m in width as well as10 sqm on plan) including disposal of excavated earth,lead upto 50m and lift from 7.5m to 9m, disposedearth to be levelled and neatly dressed.

a All kinds of soil. Cum 2327.81

6 Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excludingthe cost of chemical emulsion) at plinth andfoundation level treatment of soil using chemicalemulsion @ 5 litres/ sqm of the horizontal surface ofthe substructure with Chlorpyriphos/ Lindane E.C.20% with 1% concentration. Only Plan area shall bemeasured and paid.

Sqm 16091.897 Laying, spreading and compacting stone aggregate of

specified sizes of 90 to 45mm & 63 to 45mm inuniform thickness, hand picking, rolling with 3wheeled road / vibratory roller 8-10 tonne capacity instages to proper grade of coarse aggregate andcompacting.

Cum 8341.16REINFORCED CEMENT CONCRETE WORK

8 Charges for making holes in RCC walls, slabs or anyother RCC member by core cutting machine of Hilti /Fischer/ Mungo including disposing the debris.Measurement will be taken for the depth of holes inrunning meter for specified diameter. For disposal ofthe debris specification of relevant items shall befollowed. For all floors/ all heights.

Name of work: Construction and Development of Agri- Food Cluster Campus of National Agri FoodBiotechnology Institute ( NABI) at Mohali ( Punjab)

NON SCHEDULE ITEMS ( CIVIL) SCHEDULE-B

Page 43: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

a upto 100mm dia metre 91.00

b From 101 to 200mm dia metre 119.00

c From 200 to 300mm dia. metre 61.00

d From 301 to 450mm dia. metre 53.00

9 Providing and laying in position PVC sleeves of 6kg/cm2 UPVC pipes of approved make of differentdiameters for taking out service pipelines, cables etc.as per required beam/wall thickness for all floors / all levels / all heights.

a 50mm Diameter. each 71.00

b 75mm Diameter . each 120.00

c 110mm Diameter. each 172.00

d 160mm Diameter. each 141.00

e 225mm Diameter. each 83.00

10 Deduct for using of PPC cement in any work insteadof OPC cement. Tonne 30315.55

BRICK WORK

11 Providing and fixing hexagonal chickenmesh of size20mm x 20mm of 22 gauge at junction of concreteand brick work or between different materials etc. asdirected by Engineer-in- Charge.

Sqm 3050.11FLOORING

12 Formation of roughened strip 2.5 cm wide to formantiskid surface on floors & steps as per designincluding forming straight deep curved gishi (groove)6 mm wide & 4 mm deep on two sides of theroughened area, chiseling, polishing the edges, sidesand bottom of gishis etc. complete as per sampleapproved by Engineer-in- Charge..

metre 3175.1513 Providing & laying sandwich platform comprising of a)

Sandwich of 18 mm thick single side polish Granite ofapproved size, shade and sample on top and 25 mmthick polished kota in bottom with 25mm thick Cementmortar 1:4 (1 cement : 4 Coarse sand) in between b)At centre vertical sandwich supports of 25 mm thicktwo kota stone on sides and 10mm thick Cementmortar 1:4 (1 cement : 4 Coarse sand) in betweenwith finished groove and at both end walls verticalsupports of 18 mm thick double side granite. c) 75mm raised platform at bottom with kota on top and75mm Cement mortar 1:4 (1 cement : 4 Coarse sand)at bottom, kota stone skirting as per design andapproved sample. The rate includes rounding,champhering and mirror polishing of edges, facias ofgranite and bonding with necessary bonding adhesive. Rate shall be also inclusive of making holes & cutoutsfor SS sink, Oval wash basin, Piller tap / Bib tap etc.as directed by Engineer- in-Charge. (Only plan areashall be measured & paid for and exclusive of MSworks).

Sqm 104.8

Page 44: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

14 Providing & laying water trough of 75 mm thicksandwich granite of any size, shade and sample atoutside skirts supported on 18mm thick granite restedon 40mm thick kota stone at bottom with skirting/dado of 18mm thick granite on wall including average35mm Cement mortar 1:6 (1 cement : 6 Coarse sand)in between sandwich and wall fixing with cementmortar 1:2 (1cement:2coarse sand) of 18mm thickgranite as per design and approved sample for allfloors / all levels / all heights. The rate shall beinclusive of rounding, champhering and mirrorpolishing of edges, facias of granite, making holes &cutouts for sink, ovel wash basin, piller tap, bib tap-couplin etc. including necessary bonding adhesive asper approved make. (Only plan area shall bemeasured and paid for).

Sqm 63.0015 Providing & laying china mosaic flooring for plain and

curved surfaces at floor, dado, otta etc. comprising of20 to 25 mm size broken pieces of ceramic/ glazedtiles laid over cement mortor 1:6 (1cement:6 coarsesand) bedding including applying cement slurry at therate of 2.75 kg per sqm on plain or sloped surfacesand filling joints with white cement. The flooring/ dadoshall be tampered with wooden rammer not exceeding2 Kg in weight to bring the mortar up to the surfaceincluding rounding of the junctions and extendingthem upto 15 cm along the parapet wall. The rateshall include any type of bands, vata, any colour i/ccuring, cleaning with water and oxalic acid etc.complete as sample approved by Engineer-in-Charge.(Only plan area shall be measured including vata upto150mm height).

Sqm 6985.7816 Providing & laying average 25 mm thick machined cut

green rough kota of approved quality, selected and sorted for uniform color & texture in floor, otta, sill, skirting, tread, riser etc., in required sizes upto 600 mm as per design normal pattern (straight or staggered joint with square or rectangular shaped stone) and drawings (with grooves of 10mm wide or without grooves). Kota stone is to be laid over cement mortar 1:6 (1 cement:6 coarse sand) bedding of average 40mm thickness with joints, pointing and finishing and filling the grooves with cement mortar 1:2 ( 1cement:2 coarse sand) as sample approved including curing and cleaning with wire brush to remove excess cement on the sides of stone upto the satisfaction of the Engineer-in- Charge complete.

Sqm 1377.40Providing, fixing and laying PVC (Poly Vinyl Chloride)flexible and conductive single layer homogeneousantistatic flooring roll/ tile/ plank approved shade,pattern as per design with veined surface pattern andnon directional chip texture as per EN649, protectsurface treatment of approved color & shade ofwearing resistance 0.15mm as per EN 660.1 and EN-649 and sample approved by Engineer-in-Charge. Thesheet would have of thickness of average 2 mm, widthof 1.5 m to 2 m & length between 15 m to 25 m &newly improved Continious Graphite Backing for betterflow of charges till the earthling points. Thermal Welding: The joints must be welded by the heat fusionprocess to get a seamless floor. The joints in theflooring should be sealed by using a PVC welding barof matching colour to be supplied by themanufacturer, using a hot air gun for fusion of weldingbar with flooring. The sheet should have residualindentation of 0.06mm as per EN 433, the colorfastness > 6 as per ISO105-B02, vertical resistance <1X106 Ohm as per EN1081

17

Page 45: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

and the static electric charge < 2 kV as per EN1815.The product should also confirm to class Bfl - s1inflammability test as per EN 13501-1, slip resistanceof R10 as per BGR 181, dynamic coefficient of frictionwith class DS as per EN13893. The wear group ofsheet is P as per EN 649. The application should alsoinclude coving, capping & welding wherever required.Adhesive shall be used as per manufacturer’sspecification .Flooring rolls/ sheets are to be fusionwelded of matching color and should not appearvisually. The rate includes making seamless joints,cleaning the flooring, welding rods, coving, wallcapping as per manufacturer specification, takingprecautionary measures till handing over to client etc.complete as directed by Engineer-in-Charge .

18 Providing & laying at least 3 mm thick self leveling compound to achieve 0-0 leveled surface for vinyle as per manufacturer specification which is suitable to PVC flooring in all manner. Adhesive to be used as per manufacturers recommendation. Sqm 729.56

FINISHING

19 Providing and applying 1 coat of primer and 2 coat ofanti-fungal, anti-bacterial and anti-microbal paint forinterior use of any color , at any height/ any floor/ anylevel which is not only water proof and washable butalso covers hairline cracks and provides protectionagainst bacteria that promotes better hygiene andhealth for interior walls and ceilings as permanufacturer's specifications and as directed byEngineer-in-Charge. Sqm 1023.16

20 Providing and fixing of 12mm thick Cement BondedParticle Board over MS/SS member Structure to forma parapet/ Railing including providing, cutting boards,fixing boards to MS/SS Structure with SDSTcountersunk screws or company manufactured screwswith spacing not more than 20cms, finishing of jointsand both side painting of boards with external "Apex"paint with miniumum three coats etc. complete(Board area shall be measured for payment.MS/SSmembers shall be paid separetly).

Sqm 994.26ALUMINIUM WORK

21 Extraover on each section bending charges for anydiameter of circular window as suggested and directedby Engineer -in-Charge. each 46.00

22 Extra Charges for providing frosted glass.Sqm 2304.82

23 Extra Charges for providing toughened glass. Sqm 3908.61

24 Providing and fixing 6mm thick Wired Glass with 1 mmthick Stainless steel ( SS304 grade) wire @ every 1cm horizontal & vertical of any size, any shape inframe and shutter work with necessary cutting ofglass including providing and fixing with EPDM qualityrubber/ silicon sealant/ structural sealant /3M tape onthe periphery of the glass as per the requiredthickness etc. complete at all floors/ all levels/ allheights as per the directions of Engineer-in-Charge.Actual installed quantity shall be measured and paid.

Sqm 6138.47

 

25 Providing and fixing 6mm thick Compact Sheet of anysize, any shape, any color for providing in aluminiumframe and shutter work with necessary cutting ofsheet, single side, double side coloured includingproviding and fixing EPDM quality rubber/ siliconsealant/ 3M tape/ screwing on the periphery of thesheet as per the required thickness etc. complete atall floors/ all levels/ all heights as directed byEngineer- in- Charge . Cut edges of the compact sheetshall be provided with masking tape. Actual installedquantity shall be measured and paid.

Sqm 6382.55

Sqm 587.66

Page 46: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

26 Extra charges for machined Perforation in compactsheet ( The area of sheet on which perforations madeshall be measured.Perforations shall be of area size 1sqcm to 5 sqcm)

Sqm 611.5327 Providing & fixing 2mmx2mm x18 gauge Stainless

steel (SS304 grade) wire mesh with screw & fixingassembly in aluminium section for doors, windows,ventilators, partition, cabinets as approved byEngineer - in- Charge.

Sqm 273.6828 Providing and fixing Stainless Steel ( SS 304 grade)

Mosquito Net of 1.5mm x 1.5mmx 27 Gauge of anysize, any shape, any color in Aluminium frame /shutter work as directed by Engineer -in - Charge.

Sqm 1400.1129 Providing and fixing of 30micron anodised aluminium

fixed horizontal louvers as per manufacturer'sspecifications and their established system ( of unitwt. 0.514 Kg/m @ 8cm centre to centre)of any size ,any colour,any pattern, i/c required accessories andfixtures complete as approved by Engineer-in-Charge.Work to be done by specilized agency mentioned in listof approved makes.

Sqm 2855.4230 Providing and fixing of 30micron anodised aluminium

adjustable openable louvers as per manufacturer'sspecifications and thier established system( of unit wt.0.80Kg/m @ 6cm centre to centre) of any size,anycolour, any pattern i/c required accessories andfixtures complete as approved by Engineer-in-Charge.Work to be done by specilized agencymentioned in list of approved makes.

Sqm 389.4531 Providing & fixing heavy duty "Europrofile Mortise

Deadlock" (12.6cm 1CK brass) with minimum 6 keysin door/ window with necessary screws complete asapproved by Engineer-in-Charge.

each 885.0032 Providing & fixing Stainless steel ( SS 304 grade)

Baby latch "Door Bolt" size of 3.5" with indicator hairline finish in door/ window with necessary s.s. screwscomplete as approved by Engineer -in-Charge.

each 395.8033 Providing and fixing "Sliding lock with auto locking "

for sliding door/ window with necessary s.s. screwscomplete as approved by Engineer -in-Charge.

each 846.0034 Providing & fixing heavy quality Stainless steel AISI

316 grade "Butt Hinge with 4 Bearing" of 102 X 76 X3mm of brush/ satin finish with necessary s.s. screwscomplete as approved by Engineer-in-Charge.

each 3115.0035 Providing & fixing heavy quality Stainless steel AISI

316 grade Butt Hinge without Bearing of brush/ satinfinish with necessary s.s.screws complete asapproved by Engineer-in-Charge.

each 213.0036 Providing and fixing double action hydraulic floor

spring of approved brand and manufacture conformingto IS : 6315, having brand logo embossed on the body/ plate with double spring mechanism and capable oftaking door weight from 126 to 180 Kg (extra heavyduty ) for doors, including cost of cutting floors,embedding in floors as required and making good thesame matching to the existing floor finishing and coverplates with brass pivot and single piece M.S. sheetouter box with slide plate etc. complete as per thedirection of Engineer-in-charge.

each 50.0037 Providing & fixing Stainless steel (SS 304 grade) of

brush/ satin finish specified size Tower Bolt in door/window with necessary screws complete as approvedby Engineer -in-Charge.

Page 47: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

a 18" x 10mm (square) each 1361.00b 4" x 10mm (square) each 505.00

38 Providing & fixing Stainless steel AISI 316 gradeglossy/ satin finish specified size Push-Pull Handle inpairs in door/ window with necessary screws completeas approved by Engineer -in-Charge.

a 32mm (diameter) x 2400mm Pair 19.00

b 22mm (diameter) x 300mmPair 387.00

c 19mm (diameter) x 250mmPair 206.00

d 19mm (diameter) x 150mmPair 703.00

39 Providing and fixing Satin nickle finish BRASS ALDROPof size 100MM X 45MM with 25mm x 45mm counterwith necessary screws complete as approved byEngineer -in-Charge.

each 1095.0040 Providing & fixing 3" PVC Nylon Buffer in door/

window with necessary screws complete as approvedby Engineer -in-Charge.

each 1404.0041 Providing & fixing Stainless steel (SS 304 grade)

1"series of Ball Bearing for sliding door/ window withnecessary screws complete as approved by Engineer -in-Charge.

each 2021.0042 Providing & fixing Stainless steel AISI 316 grade

glossy/ satin finish of specified size 10mm X 128mm(C/R-type) Handles in door/ window/ cabinet withnecessary screws complete as approved by Engineer -in-Charge.

each 310.0043 Providing & fixing Stainless steel AISI 316 grade

glossy/ satin finish of specified size 10mm X 96mm(C/R-type) Handles in door/ window/ cabinet withnecessary screws complete as approved by Engineer -in-Charge.

each 182.0044 Providing & fixing Stainless steel (SS 304 grade )

Medium Magnetic Catcher for door/ window/ cabinetwith necessary screws complete as approved byEngineer -in-Charge.

each 903.0045 Providing & fixing Stainless Steel (SS304 grade )

10”x14mm rectangle type Aldrop with necessaryscrews complete as approved by Engineer -in-Charge.

Pair 1171.0046 Automatic sliding Door:-

Providing , fixing and commissioning Double LeafSliding door of approved make in curved/ plainopening with glass partition of size 6350 mm (W) *3450 mm (H) made from 6mm clear glass encased inheavy duty aluminium section duly powder coated (50 micron)consisting of 2 sliding glass leaves( 10mmtoughened glass) of size 1500mm (W) * 2400mm (H)each as specified by manufacturer with fittingaccessories, electromechanical lock with manualrelease device, digital programmer switch, back upbattery etc complete all with Double leaf sliding dooroperator, with built‐in photocells and a pair ofmicrowave radar complete.

each 1.00

Page 48: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Providing, fixing & designing of Curtain Wall with DGUsystem at all levels/ all heights/ all floors throughdesigning and selection of aluminum profiles (Aluminium sections will be for outer frame131.16mm*38.5mm*2.00 mm thick, mullion will be131.16 mm*67*2.00 mm thick and transim will be81.16mm*67mm *2.00mm thick) by minimumanodizing of 50 microns of approved color/ standardwith necessary corrosion resistance accessories/fittings, specially extruded EPDM gaskets, speciallyselected fittings for their fixing on the structuredepending on the structural conditions, functional andstatistical load requirements. System should provideproper rebate areas for air pressure compensation andwater drainage at the required stages. Selection ofglazing to be made as per structural stability, panelsize, wind load before execution. Transom fixing shallbe by overlapping joint. Transom screwing shall beable to bear the dead load of the any type of infill.

For higher field weights, additional transom fixing withaluminum connecting brackets and subsequenttransom assembly shall be provided. Verticalconnections shall have vertical expansion joints.Pressure compensation and drainage from openrebates of transom sections in mullion channel shall beup to the base point.

Note:- 1. For The purpose of payment, only the actualarea of structural glazing (including width of grooves )on the external face shall be measured in sqm. up totwo decimal places.Note:-2. The following performance test are to beconducted on structural glazing system from thecertified laboratories accreditated by NABL(NationalAccreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies,India. Cost of testing is included in this rate.Performance Testing of Structural glazingsystem Tests to be conducted in the NBLCertified laboratories:

Supporting shims shall be laid on aluminum shims forload denudation. Thermal Break shall be provided bythe contractor. Incase of openable panel handle andcurtain wall arm shall be provided. Friction Hinges/Parallel hinges shall be SS 316 of approved make. Allsections and accessories shall have to be approved byEngineer-in-Charge before execution. Rates shall beinclusive of providing 8mm thick rough ground ( 8 mmthick water proof ply) with sealant, 8mm thick coloredstructural sealant of approved make for joints betweentwo DGU panels, anodizing, approved quality anchorfasteners of size and diameter for fixing of DGUaluminium sections with adjacent wall / RCC elementsand making the entire system air and water tight,treatment of spendral portion and providing of smokeseal. Test certificates for SHGC & U-value to besubmitted to Engineer-in-Charge for verification.Contractor to submit certificate of origin & shopdrawings to Engineer-in-Charge for any approvalbefore procurement of materials. DGU Panels shouldbe factory fabricated and should be as per approvedmanufacturers specifications.DGU Glass system shallbe 6 mm reflective toughened glass + 10 to 12 mm airgap between filled with inert gas and hermticallysealed + 6 mm toughened glass which will take careof SGHC= 0.25, U value= 0.58 BTU/hr.sqft. Deg F or3.30 W/sqm K. Contractor shall submit manufacturer'sdata sheet before placing of the order to confirm ittechnical data to Engineer-in-Charge. Work to be doneby specilized agency mentioned in list of approvedmakes.

47

Page 49: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

1. Performance Laboratory Test for Air Leakage Test (-50pa to –300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) asper ASTME-331-09 testing method for a range up to2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) asper AAMA 501.01- 05 testing method for a range upto2000 ml”4. Structural Performance Deflection and deformationby static air pressure test (1.5 times desing windpressure without any failure) as per ASTME-330-10testing method for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA501.4-09 testing method for Qualitative test” Tests tobe conducted on site 6. Onsite Test for Water Leakage for a pressure range50 kpa to 240 kpa (35psi) upto 2000ml”.

49 Automatic Entance Gate:-Providing & fixing double leaf Swing gate actuator, comprising of the drive unit, integral electronic controlunit with key selector, Pair of Photocells with anodisedaluminium vertical mountings , Flashing light,additional key selector, back up battery kit mountedout side control panel, electrically operated lock (double cylinder) complete work as per manufacturer'sspecifications.Sizes : (3750 + 3750)mm width & height 1800 mm

each 1.00

48 Providing, making and fixing storage units of depth of 450 mm in position comprising of following:1) Box work, shutters and shelves shall be made from 19 mm thick BWR ply. Total number of shelves inside shall be 2 .2) Backing of boxwork shall be made from 12mm thick BWR ply.3) Laminate of 1.0 mm thickness approved make and shade on both sides of shelves, both sides of shutters and exposed visible sides of ply of box work.4) Teak wood - Best quality Ghana Teak Wood frame work 75mm X 25mm size and 6 mm thick lipping on all ply edges. 19mm x 75 mm thick base .5) Polishing: Lacquer polish on wooden and ply surfaces other than laminated surface.6) Hardware: - Hinges: SS 304 grade Butt hinges of 75 mm x 40mm for openable shutters of approved make for openable shutters - 4 hinges per shutter . - Tower bolt: Brass satin finish nickel plated or SS 304 (150 mm long)for upper shutters and 100 mm long for bottom shutters. - Handle: 150 mm long Solid rod "D" shaped handle of SS 304 grade - Magnet Catcher- of approved make 2 nos per active shutter - One multipurpose lock per active shutter of approved make - Adjustable shelves shall be fixed by 25mm x 25 mm x 3mm powder coated MS angles. 7) Onsite measurement for wardrobes, storages, etc. shall be taken before manufacturing and it shall be 6mm less from all sides adjacent to wall or ceiling. Gaps shall be filled silicon sealant of approved make and shade. The work shall be done as per sample approved and as directed by Engineer-in-charge. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles,adhesives, consumable hardwares & required SS 304 grade hardware/accessories for all floors, all heights.

Sqm 403.12

Sqm 2014.24

Page 50: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

50 Supplying and fixing modular storage facility forkitchen of approved make , specifications and tenderdrawings inclusive of necessary hardware, fixingaccessory, finishing as approved by Engineer-in-Charge . One mockup has to prepared and approvedby Engineer-in-Charge before ordering .

a Class III - Modular Kitchen ( as per tender drawing No.NA_A4_MK_III-L_03) each 8.00

b Class IV - Modular Kitchen ( as per tender drawing No. NA_A4_MK_IV-L_05) each 9.00

c Class IV - Modular Kitchen with Soft Close (as per tender drawing No. NA_A4_MK_IV-H_04) each 9.00

dClass V - Modular Kitchen with Soft Close ( as per tender drawing No. NA_A4_MK_V-H_01) each 8.00

e Director Bunglows & Guest House - Modular Kitchen , Soft Close and chimney ( as per tender drawing No. NA_A4_MK_D-H_02) each 3.00

51 Powder Coated Galvenised Iron(PCGI) Wall Panels :Providing and fixing of pre- fabricated insulatedsandwich panels made up of 0.8 mm Galvanised PlainSkin Pass (GPSP) GI Sheet with epoxy polyesterpowder coating & Insulation of PUF with density 40±2Kg /M3 as per specifications. Overall thickness of thepanel will be 80 mm . Rate includes cut out of all type, any size, any numbers , sealing the joints withsuitable adhesive with all finishing .

Sqm 550.0052 Cladding Panels:

Providing and fixing of pre- fabricated insulatedsandwich panels made up of 0.8 mm Galvanised PlainSkin Pass (GPSP) GI Sheet on both side with epoxypolyester powder coating & Insulation of PUF withdensity 40±2 Kg /M3 as per specifications.Overallthickness will be 44 mm .Rate includes cut out of alltype, any size, any numbers , sealing the joints withsuitable adhesive with all finishing .

Sqm 487.0053 Non Walkable Ceiling Panels:

Providing and fixing of pre- fabricated insulatedsandwich panels Made up of 0.8 mm Galvanised PlainSkin Pass (GPSP) GI Sheet on both side with epoxypolyester powder coating & Insulation of PUF withdensity 40±2 Kg /M3 overall to fit within each otherwith Self Supported systemthickness will be 44 mm.Panel designed to fit within each other with SelfSupported system. Rate includes cut out of all type,any size, any numbers , sealing the joints withsuitable adhesive with all finishing .

Sqm 689.5554 Providing and fixing pre-coated Aluminium Coving

having thickness 0.5 mm at junction of wall and floorhaving radius 50/65mm to match with the existingsurafces material. metre 960.00

55 Providing and Fixing of Aluminium Corner Coving (3D). Nos 127.00

56 Providing and Fixing of Aluminium Coving corner 2D.

Nos 48.00

Page 51: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

57 Clean Room Door:Providing and fixing of door fit to flush into the wallpanels. Shutter sheet thickness will be 0.8mm andFrame will be 1.2mm thick made up of GPSP GI sheetwith epoxy polyester powder coating. Leaf thicknesswill be 44mm and infill will be PUF with density 40±2Kg /M3 .

a Single leaf door size 1000*2100mmNos of Door Accessories included as per instruction of Engineer-in-Charge:SS Ball bearing hinges D handle single sideOne Side push plateDoor closer TS-68 STD armKick plate 0.8mm thick upto 300mm one sideDrop sealDoor sealDoor StopperDead Lock with both side key operationToughened glass of 400*800mm

Nos 25.00b Double leaf door size 1800*2100mm

Door Accessories included as per instruction of Engineer-in-Charge.SS Ball bearing hinges D handle single sideOne Side push plateDoor closer TS-68 STD armKick plate 0.8mm thick upto 300mm one sideDrop sealDoor sealDoor StopperDead Lock with both side key operationFlush bolt for Double leaf doorToughened glass of 400*800mm Nos 1.00

58 Epoxy flooring: Providing & laying 4mm avg. thick self levelling Epoxyflooring ( 2mm epoxy screed + 2mm epoxy selflevelling ), including levelling, cleaning of the bedsurface, treating contraction and expansion joints byfilling with approved filler, applying primer coat, etc.. The finished floor display good abrasion resistant &Monolithic Jointless surface.

Sqm 689.5559 EPOXY COVING : 75mm X 75mm

Providing, laying and fixing epoxy coving at allrequired junction i.e wall/floor, wall/ceiling, Wall/wallwhich shall be constructed with solvents very highabrasion resistant aggregates. Coving shall beimpermeable with water & flush with wall/floor/ceiling& with proper levelling at all floor, all levels, all height.

metre 207.50

Page 52: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

SANITARY INSTALLATIONNote: i) Detail of Sanitary fixture are for theinformation of the Contractor, however model /makes of all sanitary fixture shall be selected byEngineer Incharge / Interior designer / clientand the same shall be binding for execution.ii) No additional all fixing cost shall be paid forchange in type of sanitary fixture or fitting.iii) Provision of extension pieces, chairs,brackets, nuts, bolts and all accessories asrequired for final connection of CP fittings shallbe supplied and installed by the contractoraccordingly (as required).

60 Providing, Fixing & Testing of white vitreous Chinawall mounting cascade type water closet with CP bolts,nuts, CI chair hanging arrangements, bakelite seat &cover with CP hinges & rubber buffers, CP brass screw,washer with all accessories with WC connector withRubber Lip / Buffer and side gap filled with siliconsealant wherever required with chrome finished brassConcealed type dual flush valve (suitable for shaft /wall) fittings push button arrangement. Including32/40 mm dia C.P. flush pipe with clamp and adapter,rubber joint, C.P. brass wall flange, elbow completewith all other accessories including cutting, makinggood the walls, floors, slab wherever required as perdirection of Engineer-in-Charge.

a Type-1-WCHindware - WC - 20061 with seat cover or CERA 2036(carat series) with seat cover (carina) or SOMANY(MIDO) 120515 with seat cover 120678 and Hindware -Flush valve - 850022 or CERA-CM 102 or Somany250002. each 63.00

b Type-1-WCHindware - WC - 20061 with seat cover or CERA 2036(carat series) with seat cover (carina) or SOMANY(MIDO) 120515 with seat cover 120678 and flushvalve of Jaquar - 1093 or CERA- 102 or Somany-250002. each 129.00

c Type-2-WCJaquar-CNS-WHT-WS01( CONTINENTAL) with seatcover or Kohler Patio K-18131-0 with seat cover andflush valve of Jaquar - FLV - 1085 or ROCA of dualflush fitting, of flushing capacity 3 litre/ 6 litre .

each 56.00d Type-3-WC

Jaquar-Florentine - FLS-WHT-0111 with seat cover orROCA-NEXO with seat cover and flush valve of Jaquar -FLV - 1085 or ROCA of dual flush fitting, of flushingcapacity 3 litre/ 6 litre . each 23.00

e Type-4-WCJaquar SLS-WHT-0117(SOLO) or Kohler-K-8752-0(ODEON) with seat cover-K-8752K-S-0 or ROCA-Sidney with seat cover and flush valve of Jaquar - FLV -1085 or ROCA of dual flush fitting, of flushing capacity3 litre/ 6 litre . each 2.00

f Type-5-WCCera- Compact-2837 with seat cover 2330 orHindware-Studio-Cat.No.-20061 with PVC seat coverpremium with steel hinges or Somany 120501 D'OROwith PVC seat cover and flush valve ofJaquar - FLV - 1085 or ROCA of dual flush fitting, offlushing capacity 3 litre/ 6 litre .

each 10.00g Providing, fixing & testing of jet spray consisting of jet

spray, triangular spacer attached with toilet seathinges, C.P. brass angle valve & C.P brass flexiblepipe, wall flange complete .

each 10.00

Page 53: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

61 Supply, fixing & Testing of C.P. hand spray with levercontrol (health faucet) and flexible hose 1 m longconnection with C.P. holder for hand spray complete inall respects as per direction of Engineer-in-Charge.

a Somany - 250013 or CERA - CG 106 or HindwareF160023, ABS with required accessories complete all.

each 63.00b Jaquar - ALD-CHR-573 or CERA - CG 106 or Hindware

F160023, ABS with required accessories complete all.

each 220.0062 Supply, fixing &Testing of white vitreous china flat

back wash basin with CP brass waste assembly, CPcast brass bottle trap with CP extension piece, 450mmlong CP copper connections pipes, wall flanges andrubber adapters for waste connection completeincluding CI/MS brackets and duly painted, wall flangeand union complete, including nuts, washers andvitreous china for wash basin complete recessed atthe back for the reception of pipes and fittingsincluding cutting and making good the walls floorswherever required as per direction of Engineer-in-Charge:

a Type-1-WBHindware - 10038 with full pedestal or CERA - Casino1023 with full pedestal or Somany - Uniek 110107with full Pedestal 110206 andWaste coupling - Hindware- F850001 or CERA CM 103or Somany 250008 andBottle Trap - Hindware- F850015 or CERA CM 104a orSomany 250006. each 63.00

b Type-1-WBHindware - Sola 10007 with full pedestal or CERA -Casino 1023 with full pedestal or Somany - Uniek110107 with full Pedestal 110206 andWaste coupling - Jaquar ALD- 709 full thread or CERACM 103 or Somany 250008 andBottle Trap - Jaquar ALD 769 or CERA CM 104a orSomany 250006. each 129.00

c Type-2-WBJaquar: SLS-WHT-0611, with half pedestal SLS-WHT-1505(SOLO) or Kohler K-11341-1-0 with half pedestal(FOLIO) or ROCA ( GIRALDA) with half pedestal andandWaste Coupling - Jaquar ALD-709 full thread or KohlerK-9031 IN-CP andBottle Trap - JaquarALD-769 or Kohler K-16407 IN-CP.

each 56.00d Type-3-WB

Jaquar: SLS-WHT-0610(OPAL), with half pedestal OPS-WHT-1504 or Kohler K-11341-1-0, with half pedestal(FOLIO) or ( ROCA)Giralda with half pedestal andWaste Coupling - Jaquar ALD-709 full thread or KohlerK-9031 IN-CP andBottle Trap - JaquarALD-769 or Kohler K-16407 IN-CP.

each 23.00e Type-4-WB

Jaquar: JDS-WHT-0542 (JDR-Counter Top) or ROCA(FONTANA- Counter Top) andWaste Coupling - Jaquar ALD-709 full thread or KohlerK-9031 IN-CP andBottle Trap - JaquarALD-769 or Kohler K-16407 IN-CP.

each 2.00f Type-5-WB

Cera: Canon-1012 or Hindware: Compact- 10004 orSomany: 110142 Lux andWaste Coupling - CERA CM 103 full thread or HindwareF850001 full thread or Somany 250008 full thread andBottle Trap - CERA - CM104A or Hindware F850015 orSomany - 250006.

each 15.00

Page 54: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

63 Supply, fixing & Testing of C.P. brass Wash Basinmixer with C.P. flange, overhead spout complete asrequired as per direction of Engineer-in-Charge:

a Jaquar : CON-CHR-167KNB or CERA:CP 115 orSomany:ECHO 221012.

each 181.00b Jaquar: FLR-5001B (Florentine) or Kohler K-8620IN-

ND-CP (EOLIA) single lever or ROCA Attic - Monoblock.

each 85.00c Jaquar: FLR-5233K single lever (Florentine) or Kohler

K-660IN-ND-CP (Candide) single or ROCA loft elite.

each 4.0064 Supply, fixing & Testing of 15mm Diameter C.P brass

pillar Cock with heavy CP wall Flange etc complete asper direction of Engineer-in-Charge.

a Cera - CP 109A or Hindware F290001 or Somany220901 (AAHA).

each 17.0065 Supply, fixing & Testing of C.P. brass wall mounted

sink mixer with C.P. wall flange, overhead swingingspout complete as required and making good Includingnecessary wall cutting / chasing complete as perdirection of Engineer-in-Charge.

a Jaquar - 23309 or Cera-Cl-119 or Johnson.

each 19.00b Jaquar - CON-CHR-319KN, KOHLER-SIROCCO-8616IN-

1A-CP.each 50.00

66 Supply, fixing & Testing of CP Brass Shower Mixerwith provision of over head shower with 115mm longbend pipe, in built spout, spout/shower selector withwall flange complete with all accessories complete asrequired and making good the walls:Cera - CP 112 orHindware: F280018 or Somany: ECHO (221021).

each 107.0067 Supply, fixing & testing of CP Brass 115mm long

Shower Arm with wall flange and pressure adjustableShower Rose complete with all accessories as requiredand making good the walls wherever required.

a Cera - CP 140 shower with shower arm or SomanyECHO 221027 with shower arm or Hindware F160004with shower arm.

each 107.00b Jaquar: OHS-1989 with shower arm( SHA-477) or

Kohler K-16356IN-CP showerhead with shower Arm &flange or ROCA ATTIC showerhead with shower arm &flange. each 81.00

c Jaquar: OHS-1999 SHA-483 shower head with showerarm & flange or Kohler K-16351IN-CP showerheadwith shower arm & flange. each 4.00

68 Supply, fixing & Testing of storage type water heaterof approved shade with copper container, glasswoolinsulation,stove enamelled MS jacket, thermostaticallycontrolled inner heater with pilot neon lamps, anglevalve on inlet connection, 15mm dia CP flexibleconnection pipe in inlet & outlet suitable for workingpressure of 5/8 kg/sqcm complete as per direction ofEngineer-in-Charge.

a Capacity 15 litres (Racold, A0 Smith). each 244.00b Capacity 25 litres (Racold, A0 Smith). each 2.00

Page 55: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

69 Providing , fixing & testing of white vitrous china flatback urinal with automatic flushing systemscomprising of all plumbing, electronic and electricalitems. CP brass flush pipe with CP brass elbow, CPbrass spreader, CP wall flange, infrared photo cells,eyes electrically operated solenoid valve, step downtransformer / equipment and any other item requiredto provide satisfactory functioning including necessarywall cutting / chasing and making good, as requiredfor urinal flushing complete as mentioned above as perdirection of Engineer-in-Charge.URINAL - Hindware- 60002 or CERA 5001 or Somany13024 andFLUSH VALVE Sensotronic Concealed Type for UrinalComplete Set with Installation Box with Control Cock -Jaquar- 51087 or equivalent of Parryware and Kohler.

each 36.0070 Providing & fixing white vitreos chinaware urinal

partitions , comprising of necessary wall cutting /chasing and making good, as required for urinalpartition complete as mentioned above as perdirection of Engineer-in-Charge.

each 36.0071 Providing & fixing of robe hook.

Hindware-F840007 or Cera CA 105 or Somany 23056.

each 63.0072 Providing & fixing of soap dish.

Hindware-1137N or Cera 6913 A or Somany 230505.

each 63.0073 Providing & fixing of soap dish.

Jaquar - 1131N or Cera CA 103 .

each 42.0074 Providing & fixing of C.P brass toilet paper holder

Jaquar - 1151N.

each 93.0075 Providing & fixing C.P. brass Towel rod - 600mm long

with CP screws. Jaquar - 1111NM or Kohler K-17524-CP (EOLIA) or ROCA (PLAY).

each 118.0076 Supply, Fixing of solid state, no touch operting, fully

hygienic hand drier of approved make with singleblower, with time delay, summer & winter control,music while drying, volume ON/OFF controls includingproviding necessary brackets, cable from drier to Plug,Plug top key and lock etc, complete as required.

each 53.0077 Providing & fixing C.P. brass Towel ring:

a Hindware-890003 or Cera CA 102 or Somany 230505.

each 63.00b Jaquar - 1121N or Kohler K-17528 (EOLIA) or ROCA

(PLAY). each 269.00

COLD AND HOT WATER SUPPLY (INTERNAL)78 Providing and fixing of GI pipe complete with GI

fiitings and clamps, including cutting and making goodthe wall as per direction of Engineer-in-Charge.Internal Work - Exposed on wall

a 65 mm dia. metre 580.00

b 80 mm dia. metre 285.00

c 100 mm dia.metre 280.00

d 150 mm dia.metre 75.00

79 Providing and laying two coats of Synthetic enamelpaint of approved shade on pipes and supports as perpipe colour code over a coat of primer. Includingpainting of legends with direction arrow as per theapproval of Engineer-in-Charge.

a 65 mm dia.metre 580.00

b 80 mm dia. metre 285.00

Page 56: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

c 100 mm dia.metre 280.00

d 150 mm dia.metre 75.00

80 Providing, Fixing & Testing of nitrle rubber insulationon hot water supply pipes as per direction of Engineer-in-Charge.

a 15 mm dia (9 mm thickness).metre 726.00

b 20 mm dia (9 mm thickness).metre 585.00

c 25 mm dia (9 mm thickness).metre 120.00

d 32 mm dia (13 mm thickness).metre 30.00

e 40 mm dia (13 mm thickness).metre 50.00

f 50 mm dia (13 mm thickness).metre 30.00

g 65 mm dia (13 mm thickness).metre 10.00

81 Providing, Fixing & Testing of full way lever operatedforged brass ball valve of brass body with forged brasshard chromeplated steel ball tested to a pressurerating of PN 16 with threaded / flanged jointscomplete with nuts, bolts, gaskets, washers union etcas per direction of Engineer-in-Charge.

a 15 mm dia.each 65.00

b 20 mm dia.each 270.00

c 25 mm dia.each 121.00

d 32 mm dia. each 232.00

e 40 mm dia.each 59.00

f 50 mm dia.each 63.00

82 Providing, Fixing & Testing of butterfly valve (Body :Grey Cast Iron, Shaft : SS, Disc : SG Iron (Rilsoncoated), Liner : HT - EPDM) (upto 150mm dia withhand lever operation & above with gear boxoperation). PN 16 Valves. Including flanges, nuts,bolts, washers & painting complete as required.

a 65 mm dia.each 18.00

b 80 mm dia.each 10.00

c 100 mm dia.each 7.00

d 150 mm dia.each 2.00

83 Providing, Fixing & Testing of high pressure ratedGun Metal Float Valve with copper ball float and brassrods of required length suitable for test pressure of notless than 10 Kg/sqcm of the following sizes:

a 20 mm dia.each 4.00

b 25 mm dia.each 11.00

84 Providing, Fixing & Testing of CI Air Release valve forcold water supply risers, suitable for pressure not lessthan 10 Kg/Sq.cm.

a 15 mm dia.each 298.00

85 Providing and fixing in position G.I. vent with brassmosquito proof coupling and air filter including returnbend, complete as required. The entire fitting shall behot dip galvanised.

a 100 mm dia.each 53.00

86 Providing and fixing M.S. puddle flanges fabricated of750 mm long pipe pieces to RCC water tanks wall /slab. The entire fitting shall be hot dippedgalvanised(Flanges shall confirming to BS10 Table E).

Page 57: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

a 25 mm dia (Screwed ends MS plate 6 mm thick; 125mm x 125 mm plus dia of pipe). each 60.00

b 32 mm dia (Screwed ends MS plate 6 mm thick; 250mm x 250 mm plus dia of pipe).

each 6.00c 40 mm dia (Screwed ends MS plate 6 mm thick; 250

mm x 250 mm plus dia of pipe).each 38.00

d 50 mm dia (Screwed ends MS plate 6 mm thick; 250mm x 250 mm plus dia of pipe).

each 48.00e 65 mm dia (Screwed ends MS plate 6 mm thick; 250

mm x 250 mm plus dia of pipe).each 24.00

f 80 mm dia (Screwed ends MS plate 6 mm thick; 400mm x 400 mm plus dia of pipe).

each 21.00g 100 mm dia (Screwed ends MS plate 6 mm thick; 500

mm x 500 mm plus dia of pipe).each 42.00

h 150 mm dia (Screwed ends MS plate 6 mm thick; 600mm x 600 mm plus dia of pipe).

each 23.00i 200 mm dia (Screwed ends MS plate 6 mm thick; 600

mm x 600 mm plus dia of pipe).each 2.00

87 Providing and fixing HDPE tanks with inlet,outletnipples and man hole cover.

a 500 Ltrs. each 3.00b 1000 Ltrs. each 3.00

INTERNAL DRAINAGE (SOIL, WASTE & VENT) 88 Providing, Fixing & Testing of GI inlet hopper with two

or three inlets fittings to receive waste pipes fromfixtures waste. The hopper shall be fabricated from100 mm dia upto 600 mm long GI heavy class pipeand welded GI sockets, fixed to CI trap with lead / dripseal joint and support through galvanized steelsupport from slab or set in cement concrete mix 1:2:4complete as required. The hopper shall be hot dipgalvanized after fabrication and fixed to CI trap / pipewith drip seal joint.

each 446.0089 Providing, Fixing, Testing & Commissioning of 100mm

x 50mm GI waste with reducing elbow & nipple cuttingchases, the floor / slab, repairs complete as requiredand connection to GI waste pipe.

each 259.0090 Providing, Fixing, Testing & Commissioning of Heavy

class SS grating with Cockroach proof SS strainer ofapproved design including setting in floor with cementmotor to match with floor finish as per Engineer-in-Charge .

a Size 127 mm x 127 mm. each 259.00

b Size 150 mm x 150 mm. each 446.00

91 Providing and fixing Brass floor clean out plugcomprising of GI pipe, socket, elbow, extension piececaulked to pipe and cast brass plug with suitable inletkey for opening male threaded joint with GI class Cpipe & socket. Including lead / drip seal caulked to CIpipes or CI class LA pipes complete as requiredincluding paint.

a 100 mm dia.each 32.00

Page 58: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Solar Water Heater System92 Providing, fixing , Testing and commissioning of Solar

Hot Water indirect heating system using approvedtype of Heating liquid medium comprising of eightnumber of flat plate solar panels, including allinterconnecting insulated G.I. piping, primary andsecondary recirculation pumps, pressure typeinsulated hot water tank, sacrificial magnesium anodewith steel core including electrical heatingarrangement, valves on inlet, outlet, Y stainer and awater meter on the inlet, air release valve all mountedon galvanized MS sections complete with connectionwith the existing piping as directed by Engineer-in-Charge and comprising of following items:

a 24 nos of flat plate solar collector panels of 2 m x 1 msize approx. The panels enclosed in insulated collectorboxes with single piece toughned glass 4 mm thickand fixed with heat resistant gasket with completeaccessories.

b 1 no of Solar HWH System 3000 lpd of hot water at55 deg.C Heat Exchanger Capacity - 35,000 BTHU/Day with complete accessories.

c 1 no of Solar HWH System 3000 lpd of hot water at 60degree C with , an insulated storage water tank ofdual vessel construction, inner vessel of stainless steelgrade 304 OR glass lined MS sheet or copper sheet towithstand a test pressure of 7 kg./sqcm with outervessel of mild steel sheathing of 3000 ltrs capacity,mounted horizontally, temperature measuring device,thermostats, inlet outlet and drain connections asrequired with complete accessories.

d Providing and fixing horizontal/ vertical monoblocsingle/multi stage pumping set for hot water pumpswith CI body, bronze impellar, stainless steel shaft andbronze shaft sleeve, (suitable for 90 deg. C. hot waterflow) connected to a TEFC induction motor suitablefor 400/440 volts, 3 phase 50 cycles A.C. supplyhaving IP 55 protection enclosure, all inter connectingpipe work & valves, pressure gauge etc. vibrationeliminating pads etc. complete with base and frame,nuts and bolts fixed over RCC foundations as perrequirement complete in all respects. (RCC foundationshall be paid in relevant item)Hot water recirculation (Cap & head as permanufacturer's approved design)

Primary pump - 2 Nos(1W+1S), Secondary pumps - 2 Nos(1W+1S),Recirculation pump - 2 Nos (1W+1S)Total 6 nos. of pumps as described above:

Solar Water Heater System comprising of all above

EXTERNAL WATER SUPPLY SYSTEM

93 Providing and fixing G.I. pipes complete with G.I.fittings including trenching and refilling etc. (externalwork):

a 100 mm nominal bore. metre 1570.0094 Making connection of G.I. distribution branch with G.I.

main of following sizes by providing and fixing tee,including cutting and threading the pipe etc. complete:

a 100 to 150 mm nominal bore. each 6.00

EXTERNAL DRAINAGE SYSTEM

System 1.00

Page 59: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

95 Providing, laying, jointing and testing in position thefollowing IS:14333 HDPE - PE 63 (PN-6.0) Pipes forlab drainage cut to required lengths making properconnections at required depths. Pipe to be laid belowground level in trenches upto required depth includingexcavation in all kind of soil (hard rock), dewatering,refilling, watering, ramming & removing the surplusexcavated material and making good the samecomplete as required. Cost shall be inclusive ofproviding protection to pipe all round CC haunches asper specification.

a 63 mm dia. metre 90.00b 110 mm dia. metre 150.00c 160 mm dia. metre 120.00d 200 mm dia. metre 250.00e 250 mm dia. metre 225.00

Page 60: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

WATER SUPPLY, DRAINAGE, PUMPS & EQUIPMENT

96 Providing and fixing GI Heavy class header completefor pump suction / discharge manifold comprising ofexpansion elbows, flanges, unions, check nuts, teeelbow etc. including all flanged connections as persite requirement. Supports from wall, floor and ceilingetc. Including dead end flanged connection completeas directed by Engineer-In-Charge.

a 25 mm dia. metre 15.00b 32 mm dia. metre 60.00c 40 mm dia. metre 60.00d 50 mm dia. metre 40.00e 65 mm dia. metre 80.00f 80 mm dia. metre 80.00g 100 mm dia. metre 40.0097 Providing , fixing & commissioning of full way lever

operated forged brass ball valve of brass body withforged brass hard chromeplated steel ball tested to apressure not less than 15 Kg / sqcm with threaded /flanged joints complete with nuts, bolts, gaskets,washers etc. as per direction of Engineer-in-Charge.

a 25 mm dia. Nominal bore. each 2.00b 32 mm dia. Nominal bore. each 2.00c 40 mm dia. Nominal bore. each 2.00d 50 mm dia. Nominal bore. each 2.0098 Providing & fixing butterfly valve (Body : Grey Cast

Iron, Shaft : SS, Disc : SG Iron (Rilson coated), Liner: HT - EPDM) (upto 150mm dia with hand leveroperation & above with gear box operation). Tested toa pressure not less than 15 Kg/Sq.cm. Includingrubber gasket, flanges, nuts, bolts, washers & paintingcomplete as required.

a 65 mm dia. Nominal bore. each 20.00b 80 mm dia. Nominal bore. each 47.00c 100 mm dia. Nominal bore. each 5.00

99 Providing & fixing gun metal horizontal flap type nonreturn valve conforming to IS 778. Including rubbergasket, flanges, union, nuts, bolts & washers completeas required.

a 40 mm dia. No. 1.00b 50 mm dia. No. 1.00c 65 mm dia. each 10.00d 80 mm dia. each 12.00

100 Providing & fixing C.I. `Y' Strainer (screwed/ flanged)with stainless steel fine wire mesh perforated sheetbasket with necessary flange/ unions nuts, bolts andwashers complete as required (on pump suction)asper direction of Engineer-in-Charge.

a 50 mm dia. each 2.00b 65 mm dia. each 2.00c 80 mm dia. each 7.00d 200 mm dia. No. 4.00

101 Providing & fixing M.S. puddle flange fabricated of 750mm long pipe pieces to R.C.C. water tank wall / slab.The entire fitting shall be hot dipped galvanised(Flanges shall confirming to BS10 Table E).

a 25 mm dia (Screwed ends MS plate 6 mm thick; 100mm x 100 mm plus dia of pipe).

each 22.00

Page 61: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

b 40 mm dia (Screwed ends MS plate 6 mm thick; 100mm x 100 mm plus dia of pipe). each 2.00

c 50 mm dia (Screwed ends MS plate 6 mm thick; 100mm x 100 mm plus dia of pipe). each 30.00

d 65 mm dia (Flanged ends MS plate 6 mm thick; 100mm x 100 mm plus dia of pipe). each 2.00

e 80 mm dia (Flanged ends MS plate 6 mm thick; 100mm x 100 mm plus dia of pipe). each 9.00

f 100 mm dia (Flanged ends MS plate 6 mm thick; 250mm x 250 mm plus dia of pipe).

each 30.00g 150 mm dia (Flanged ends MS plate 6 mm thick; 250

mm x 250 mm plus dia of pipe).each 10.00

h 200 mm dia (Flanged ends MS plate 6 mm thick; 250mm x 250 mm plus dia of pipe).

each 2.00102 Providing and fixing electronic type level indicator for

water tanks mounting in panel with the followingfeatures, level display, alarm when water level is lowor high, full range from one level to four level displayand manual reset for alarm etc. with electrical wiringconduit supports from wall & ceiling probes and allother accessories complete as required.

each 8.00103 Providing and fixing in position GI vent with brass

mosquito proof coupling and air filter including returnbend complete as required. The entire fitting shall behot dip galvanised.

a 100 mm dia. each 12.00104 Providing ,installation & testing of dial type pressure

gauge with pressure scale of 0 to 15 kg / sq.cm.Provision of isolation cock suitable for maximumpressure of 15 kg / sq.cm shall be included in cost.

each 19.00105 Providing complete testing kit with all chemicals

complete suitable for conducting test on water quality.The test kit shall be suitable to measure TDS, pH,Hardness, Iron content and other parametres .

each 2.00Supply, Installation, Testing and Commissioning OfCompact Self Contained Skid MountedHydropneumatic System as Follows:

a. Vertical, In-Line, Multisage, centrifugal pumps withSS-304 casing and impeller and SS-316 shaft, CI base& head TEFC motor (with mechanical seal).

b. Vendor to submit performance curves and technicalcatalog of the proposed model for review &information.

c. The pump shall be selected for performance at bestefficiency point. However, the pump selection shall besuitable for perfometreance with set point @ + 20% ofthe rated head.

d. External Pump mounted or wall mountedmicroprocessor PID controller and frequency inverterintegrated in a single body or as separate componentswith pressure sensor transmitter minimum two linedLCD display, diodes to indicate pump ready, pumprunning and fault and capable to communicate withother controllers following MODBUS-RTU or BACNETClass-2 protocall through RS485 port. System shouldbe capable to compensate for frictional losses at lowerflows. All alarm should be displayed in the controller.System should be equiped with dry running protection- Quantity : 1 each

106

Page 62: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

e. Complete (Skid mounted wall mounted / floormounted) electrical control panel comprising of allaccessories such as PLCs, pressure switches, pressuretransducers, control wiring and any other necessaryimports etc.

f. Precharged diaphram pressure vessel with foodgrade membrane, charging connection, connected tooutlet header with necessary flanges, gaskets,isolating valves, nuts/bolts etc complete.

g. Set of accessories such as pressure switches,pressure transducers, inter connecting power andcontrol cabling etc. complete.

h. Accessories like pressure gauge, MS base frame(Synthetic enamel painted over a coat of primer).

i. GI suction and delivery header with flanges for inlet connection, common outlet header with flanges for outlet connections as required, and inter connecting piping with flexible connections, eccentric type reducers etc. all necessary indigenous accessories as required to complete the installation.

Page 63: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Note: Contractor to note that the suction header isrequired to have inlet connection from the Puddle Flange@ water tanks and to the pump suction. Provision ofdelivery header is required to have outlet connection fromthe pumps. Suitable outlet flanges from the deliverymainfold / header shall be provided as required.

Pumps : 2 (1W+1S) Water Flow Rate : 55 LPM (each)Head : 45 M RPM 2900 Purpose : Domestic water supply

Location : Plumbing Plant Room

1 set comprises of Hydropneumatic system as above Set 2.00Supply, installation, testing and commissioning ofcontinuous duty submersible centrifugal non-cloggingdrainage pumps complete with 3 phase motor with allnecessary protection and mechanical seal etc.complete with all ancillaries including float type levelcontrollers, electrical control panels fabricatd from 14gauge CRCA sheet volt metre ammetre with selectorswitch, TPMCB, 5 VA CL : CTs, phase indicating lampsprotected by 2 Amp SP MCB, DOL starter, necessarywiring, cable alleys, earthing, interlocking, starter withAutomatic float type level controller, providion of highlevel alametre, sequence timer, potential free contactto starter for connection to BAS, both pumps may runsimultaneously at pre detemetreind level. (1 Working+ 1 Standby) Contractor to submit proposed pump model with dutycurve.

Flow rate : 360 LPMHead : 10 Mtrs Solid Handling : 10-12 MMLocation : Sump of Basement

WATER TREATMENT PLANTSupplying, installing, testing and commissioning of SSvertical centrifugal pump. each pump shall have TEFC2900 RPM three phase electric motor. The pump shallhave cast iron head, base plate SS Shaft/ Impeller/Intemetreediate chamber. Pump shall be providedwith mechanical seal. The pump shall be suitable forauto/ manual operation. The installation shall becomplete with all necessary ancillaries & accessoriesincluding base plate with vibration eliminator padscomplete as required.(1Working + 1Standby)

Flow rate :55 LPM eachHead : 35 MtrsRequired for : Filter feed pump

109 Providing, fixing, testing & commissioning of verticalDual Media FRP filter with adequate dirt holdingcapacity. The filter shall be complete having PVCfrontal piping with 50 mm multiport valve including allsupporting structure with initial charge filter media.The filter shall be provided with set of internals for rawwater inlet and bottom collecting system. Velocity infrontal piping and valves shall be 1.50 m/sec.Filter forDomestic Water services.

FRP Filter:

Filteration Rate :20000 L/Sqm/HrWorking pressure: 3 Kg/Sq.cmCapacity :55 LPMActivated Carbon Filter:

Filteration Rate :14000 L/Sqm/HrWorking pressure :3 Kg/Sq.cm

Capacity :55 LPM 2.00

2.00

No

b

107

Set 8.00

No

108

Set 2.00

a

Page 64: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Providing, fixing, testing & commissioning of FRPwater softening plant (suitable for 3 Kg/Sqcm workingpressure) complete with initial charge with T-40 NAResin, multiport valve with built in ejector forcontrolling all operations), regeneration system andHDPE tank, pressure gauge at inlet, outlet and backwash (each with isolation cock), valves, fittings andwater hardness testing kit & associated works.Velocity in frontal piping and valves shall be 1.50m/sec Softener shall be suitable for the followingduty.

Raw water hardness: 400 Mg/LTreated water hardness: 10 Mg/LCapacity :55 LPM 2.00

110

No

Page 65: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

111 Supplying, installing, testing and commissioning ofdosing system (for domestic water treatment plant)consisting of one HDPE tank of 200 litres capacity witha positive displacement diphragm dosing pump havingvariable flowrate of 0-6 lph. The motor shall besuitable for operation at 240 V/single phase/50 Hz.Supply. The pump shall be supplied complete withnecessary polypropylene piping, valves, strainers, lowlevel switch and injection fittings. The pump shall bespeed & stroke control Asia LMI / equivalent make. The cost shall be inclusive of providing salt for thetesting and operation of system before handover tothe Client.

No 2.00112 Supplying, installing, testing and commissioning of

annunciation and indication panel with interlockingarrangement complete in accordance to specificationwith level controller (In Raw Water, Treated WaterTank : High / Low Level Controller) etc with controlcabling from field to MCC as required.The system shall be complete to ensure automaticquotation of pump in accordance to water level inrespective tanks.

No 2.00 MAIN DISTRIBUTION BOARDSSupply, Installation, Testing & Commissioning , cubicletype body made out of 2mm thick CRCA sheet,totallyenclosed, IP 42, floor mounted with channel baseframe, dust and vermin proof, indoor,compartmentalised, suitable for operation on 3 phaseand neutral, 415 V, 50Hz AC system with extensiblebusbars on both sides, making interlockingarrangement including control wiring with 2.5 sq mmsize wires/cable, interconnection, duly powder coatedpainting etc. including supply & installation offollowing switchgears,metreing instruments andaccessories as per specifications.

a) INCOMER1 each 150 Amp four pole Moulded Case CircuitBreaker (Ics value 35 KA) with built in thermal basedrelease unit with adjustable setting .

b) BUSBARS150Amp TPN busbars of high conductivity electrolyticquality aluminium alloy.c) INSTRUMENTS 1 each digital multifunction metre (Ammetre +Voltmetre) for 3 phase, 4 wire operation as perspecification.

1 Sets of RYB phase indicating lamps controlled by 2amp MCB.d) OUTGOINGi) 1 Nos. 40 amps TP MCCB (Ics value 35 KA)outgoingfeeder to 1 each Domestic Water pump.

ii) 2 Nos. MPCB with (Ics value 35 KA) DOL starter ofsuitable rating for outgoing feeder to Filter feed pumpmotor 2 each 5 HP(1working + 1Stand by). eachcompartment shall contain direct & analogue typeAmmetre , auto / manual selector swtich andindicating / pushbutton lamps with MCB for ON / OFF /TRIP of motor.

iii) 4 Nos. MPCB with (Ics value 35 KA) DOL starter ofsuitable rating for outgoing feeder to Bore well pumpmotor 4 each 15 HP (2working + 2Stand by). eachcompartment shall contain direct & analogue typeAmmetre , auto / manual selector swtich andindicating / pushbutton lamps with MCB for ON / OFF /TRIP of motor.

113

Page 66: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

iv) 4 Nos. MPCB with (Ics value 35 KA) DOL starterof suitable rating for outgoing feeder to Sump pumpmotor 4 each 3 HP ((2working + 2Stand by).eachcompartment shall contain direct & analogue typeAmmetre , auto / manual selector swtich andindicating / pushbutton lamps with MCB for ON / OFF /TRIP of motor.

v) 8 Nos. MPCB with (Ics value 35 KA) DOL starter ofsuitable rating for outgoing feeder to stormwater drainage sump pump motor 8 each 2 HP (4working +4Stand by). each compartment shall contain direct &analogue type Ammetre , auto / manual selectorswtich and indicating / pushbutton lamps with MCB forON / OFF / TRIP of motor.Note:All breakers shall bemechanical interlocked with suitableaccessories.Separate neutral link shall be provided inall 3 Pole feeders.All breakers breaking capacities shallbe ICU=ICS.

Main Distribution panel consisting of all above No 2.00

Page 67: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Fire Fighting SystemSupplying, installing, testing & commissioning ofelectric driven Main Fire & sprinkler Pump suitable forautomatic operation complete consisting of thefollowing:Horizontal split casing centrifugal suction type pump ofcast iron body & bronze impeller with stainless steelshaft, mechanical Seal to ensure a minimum pressure3.5 kg/cm2 at highest and farthest outlet at specifiedflow of 2280 ltrs./minute against a total head of 70metres confometreing to IS: 1520.

Squirrel cage induction motor suitable for 415 V, ±10%, 50 Hz, AC supply of suitable rating for the abovepump with synchronous speed of 1500 RPM T.E.F.C.type such as confirming to IP:55 protection forinclosure, horizontal foot mounted type wth Class-'F'insullation, confometreing to IS: 325 and flexiblecoupling and coupling guard with the pump.

Mild steel fabricated Common bed plate of channel,foundation bolts ect.

Suitable reinforced cement concrete pump foundationincluding cushy foot mounting, foundation bolts,washers with anti vibration pads as required.

Supplying, installing, testing & commissioning ofDiesel Engine driven main fire Pump suitable forautomatic operation consisting of the following (as perspecification).

Horizontal split casing multistage centrifugal suctiontype pump of cast iron body & bronze impeller withstainless steel shaft, mechanical Seal to ensure aminimum pressure 3.5 kg/cm2 at highest and farthestoutlet at specified flow of 2280 ltrs./minute against atotal head of 70 metres confirming to IS: 1520.

Suitable HP, 1500 RPM water cooled with radiator,Diesel Engine confirming to relevent BS & IS standardcomplete with auto starting mechanisum, 12 volts/24Volts electric starting equipment i/e suitablemaintenance free batteries of 12 V, 180 AH. Dieseltank 400lts. with first charge and manual oil pumpset., Exhaust pipe extended upto open top of buildingas per requirement duly insulated with 50 mm thickglass wool with 1.0 mm thick aluminium sheetcladding, residential silencer , instruments andprotection as per specification, stop solenoid for autostop in the event of fault with audio indications,painted with post office red colour ect. as required,common bed plate for mounting of engine.

Mild steel fabricated Common bed plate of channel,foundation bolts ect. as required.

Suitable reinforced cement concrete pump foundationincluding cushy foot mounting, foundation bolts,washers with anti vibration pads as required.

Providing & fixing, testing and commissioning ofelectrical driven jockey pump (pressurisation pump)suitable for automatic operation and comprising offollowing: complete in all respect as required.

Horizontally mounted centrifugal end suction typeJockey pump complete of cast iron body & bronzeimpeller with stainless steel shaft, mechanical Sealdelivery of 180 ltrs/minute against a total head of 70metres approx complete with arrangement for testingof the working of the pumping set as requiredconfirming to IS: 1520. Rate shall also includeMechanical Seal.

No 2.00116

115

114

No 3.00

Page 68: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Squirrel cage induction motor T.E.F.C type suitable operation on 415 V ± 10%, 3 phase 50 Hz AC supply wit IP 55 class of protection for encloser, horizontal foot mounted type class - 'F' insulation, confirming to IS : 325 of suitable rating for the above pump with synchronous speed of 2900 RPM and flexible coupling and coupling guard with the pump.

Mild steel fabricated Common bed plate of channel,foundation bolts ect. as required.

Suitable reinforced cement concrete pump foundationincluding cushy foot mounting, foundation bolts,washers with anti vibration pads as required.

No 2.00

Page 69: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Main Distribution Boards (Fire Fighting)Supply, Installation, Testing & Commissioning , cubicletype body made out of 2mm thick CRCA sheet,totallyenclosed, IP 42, floor with channel base frame, dustand vemetrein proof, indoor, compartmentalisedextensible segregated hinged lockeble door, suitablefor operation on 3 phase and neutral, 415 V, 50Hz ACsystem with extensible busbars on both sides, makinginterlocking arrangement between incomers &buscoupler breakers, including control wiring with 2.5sq mm size wires/cable, interconnection, duly powdercoated painting etc. including supply & installation offollowing switchgears,metreing instruments andaccessories as per specifications.

INCOMER1 each 150 Amp four pole Moulded Case CircuitBreaker (Ics value 50 KA) with built in microprocessorbased release unit with adjustable setting .

INSTRUMENTS2 each digital multifunction metre (Ammetre +Voltmetre) for 3 phase, 4 wire operation as perspecification.

2 Sets of RYB phase indicating lamp scontrolled by 2amp MCB & with toggle switch

BUSBARS200Amp TPN busbars of high conductivity electrolyticquality aluminium alloy.OUTGOING2 Nos. 125 amps TP MPCB (Ics value 50 KA) withinbuilt thermal magnetic release with all acessoriesincluidind 1 each Auto DOL starter suitable for 60 HPwith, single phase preventor oil relay ammetre withCTs `ON'/OFF`TRIP' indicating lamp and pushbottons, potential free contacts for remote operationin each feeder and auto / manual selector switchcomplete as required. (out going feeders to Hydrant /Sprinkler pump motor.)

1 Nos. 40 amps TP MCCB (Ics value 35 KA) withinbuilt thermal magnetic release with all acessoriesincluidind 1 each Auto DOL starter at 10 HP with,ammetre with CTs `ON'/OFF`TRIP' indicating lampand push bottons, potential free contacts for remoteoperation in each feeder and auto / manual selectorswitch complete out going feeders to Hydrant Jockey/Sprinkler Jockey pump motor.(2 Sets)

Diesel Engine Control:

Control for Diesel Engine comprising:-Auto/ Manual selecator switch & 3 attempt stratingdevice, timers and relays as required, push buttons,strat/stop in manual mode.

Indication lamp for High/ Low Lub. Oil pressure, HighWater Temp. and Engine ON Indication.

Battery chrager suitable for 12 V/ 24 V DC with boostand tickle selector switch, 0-30 V DC volt metre, 0-20A DC Ammetre.

All standard senescing and protection relays andaccessories for automatic operation of diesel engine.

System ControllerDesigning, Supply, Installation, testing andcommissioning of system controller to controloperation of main electric fire pump, diesel pump,pressurisation pump, terrace pump in sequence as perspecification consisting of relays, timers, sensors,annunciation window for fault indication, complete asper specification

117

Page 70: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Note:All breakers shall be mechanical interlocked withsuitable accessories.Separate neutral link shall be provided in all 3 Polefeeders.Spare Feeder & 4 each MPCBAll breakers breaking capacities shall be ICU=ICS

Indication Panel in Fire Control RoomFabrication, supply, installation, testing &commissioning of wall mounted remote indicationpanel for fire fighting system fabricated from not lessthan 1.6 mm. thick CRCA sheet, powder coated ofapproved shade, complete internal wiring, indicatinglamps, relays, accessories, numbering, letteringcomplete in all respect and consisting of the followingas required.

ON/OFF indication of main electrical fire pump and Sprinkler pump, pressurisation pump.

Audio/Visual indication of operation of main electric/diesel fire pump with reset push button.

Pressure indication in fire fighting system (pressure transducer to be installed under separate item.)

Failure of Hydrant pump to startHigh level in fire water storage tank compartmentLow level in fire water storage tank compartmentLow level in HSD day tank of the fire pumpSupplying, installation, testing and commissioning ofannunciation panel made out of not less 1.6 mm thickCRCA sheet powder coated in approved colour withlocking arrangement, audio and visual indication offault and operation of automatic sprinkler, systemmonitoring including providing and fixing the following,connections interconnections etc. complete asrequired.

Monitoring 1 Nos. of flow switches.Moniotoring the open circuit, short circuit & earth faultin control cable between panel and flow switches.

Battery charger trickle cum boost to take completeload of annunciation panel complete with indication oflow battery voltage, mains failure and otheraccessories including providing and fixing of 2 No 12volts 24 AH each sealed maintenance free batteries.

Audible alarm.

Supply, installation, testing and commissioning ofTerrace fire pump comprising of the following:a. Horizontal mono-block centrifugal pump, suitablefor operation on 415 volts ± 6%, 3 phase, 50 HZ A.Csupply.

The pump casing shall be CI, shaft shall be CS &impeller / shaft sleeve / casing wearing ring shall bebronze. The system shall be complete with necessarypressure gauge with gun metal shut off cock ondelivery side. (The pump should meet the condition and shall begotten approved by the Local fire Authority).

b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with speed of 2900 R.P.M.

c. Suitable cement concrete foundation with plaster,(design and drawing to be provided by the Contractorwhile the foundation will be done by others) completewith Antivibration arrangement of cushy footmounting.For pump defined above & of duty as follows :Flow : 450 LPM

Head : 40 mts

2.00No

2.00

No

119

No 2.00

118

No

120

1.00

Page 71: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

121 Supplying and laying of XLPE insulated PVC strandedaluminium conductor 1.1 kv grade (ametreoured) U.G.power cable following size on existing cable traysuitably clamped with termination with aluminium lugsat both ends as required conforming to IS : 7098 asamended.

a 3.5 core 95sq. mm. metre 30.00b 3 core 50 sq. mm. metre 30.00c 4 core 16 sq. mm. metre 30.00d 3 core 16 sq. mm. metre 30.00

122 Supplying of following 1100 volt grade PVC insulatedsheathed copper conductor un-armoured cable as perspecification in existing trenches, cable trays ductsover bed of sand, clamped includes anchor fastners towall with suitable clamps, saddles fixing bolts includingconnecting testing and commissioning.

a 3 core x 4 sq. mm. metre 10.00123 Providing, fixing, testing and commissioning of

precharged air vessel (size 250 mm dia & 1200 mmheight of 8.0 mm thick MS sheet) for pressurization ofhydrant / sprinkler system complete with 2 nospressure switches with vibration dampner, 2 nosPressure gauges, 8 nos 15 mm dia SS needle valves ,one no 25 mm dia drain valve, air release valve ontop and flanged connection to riser with stop cock onthe top, 25 mm dia inlet with isolating valve dulypainted from inside and outside complete as required.

each 2.00124 Supplying, testing, installation & commissioning of

pressure switches for Hydrant, Sprinkler, Standby andJockey & Booster Pumps, including necessary wiringupto control panel & other materials.

each 10.00125 Providing and fixing electronic type level indicator for

water tanks mounting in panel with the followingfeatures, level display, alarm when water level is lowor high, full range from one level to four level displayand manual reset for Alarm etc. with electrical wiringconduit supports from wall & ceiling probes and allother accessories complete as required.

each 2.00126 Providing & fixing electronic type water level indicator

with LED panel mounted as required by the Engineer-in-Charge complete with probes & all control wiringetc.

each 2.00Providing, laying, jointing, testing , commissioningand painting with two coats of synthetic enamel paintwith primer of following sizes of MS Class "C" pipesconforming to IS-1239 with all accessories like allfittings (standard MS fitting with welded joint shall beused on the pipes) including tees, elbows, headers,reducers, union, flanges, rubber gaskets, GI nutsbolts, washer including supporting/fixing the pipe onfloor / wall /ceiling with galvanised clamps,hangers(using anchor fastners) as per specification. GI pipesleeve of suitable higher size shall be providedwherever the pipes are crossing the walls/floors andsealing the sleeves with glass wool in between & firesealent compound at either end all as per Engineer-in-Charge requirements including cutting holes andchases in brick, RCC work and making good the sameto original conditions complete in all respects. Allhangers, clamps, brackets etc. shall be of galvanizediron unless specified otherwire and then supply of thesame shall also be included for rates under this head.Welding of any kind on the galvanized support /hanger shall not be permitted.

127

Page 72: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

a 25 mm dia. metre 1950.00b 32 mm dia. metre 75.00c 40 mm dia. metre 815.00d 50 mm dia. metre 1220.00e 65 mm dia. metre 320.00f 80 mm dia metre 265.00g 100 mm dia. metre 215.00h 150 mm dia. metre 1610.00i 200 mm dia. metre 5.00

128 Providing, laying, jointing and testing in trenches thefollowing sizes of MS class `C' (heavy class) pipesconforming to IS: 1239 with accessories like fittingsincluding tees, elbows, reducers, flanges, rubbergaskets, GI nuts, bolts and washers includingexcavation in all kind of soil, refilling, ramming,shoring, removing the excavated surplus material,providing cement concrete support to the pipe andmaking good the same complete as required. Rateshall include for dewatering necessary to execute thework. The pipe shall not be laid less than 1.0 m belowground level at any point. Pipes shall be embedded allaround 150mm thick compacted silver sand andproviding protection to embedded MS pipes andfittings and providing anticorrosive treatment with 4mm thick coal tar as per IS: 10221 & Specification.

a 80 mm dia. metre 185.00b 150 mm dia. metre 225.00

129 Providing, fixing, testing & commissioning of butterflyvalve PN 1.6 (Body : Grey Cast Iron, Shaft : SS, Disc :SG Iron (Rilson coated), Liner : HT - EPDM) (upto150mm dia with hand lever operation & above withgear box operation).Bronze / Gun metal sealIncluding rubber gasket, flanges, nuts, bolts, washers& painting complete as required.

a 150 mm dia. each 16.00b 200 mm dia (Gear Operated). each 11.00

130 Providing, fixing, testing & commissioning of CI wafertype dual plate check valve PN 1.6 including rubbergasket, flanges, union, nuts, bolts, washers & paintingcomplete as required.

a 65 mm dia. each 3.00b 100 mm dia. each 1.00c 150 mm dia. each 21.00d 200 mm dia. each 3.00

131 Providing, fixing, testing & commissioning of CI `Y'strainer with bronze perforated sheet basket includingrubber gasket, flanges, nuts, bolts and washers,complete as required and suitable for systempressure.

a 80 mm dia. each 17.00b 200 mm dia. each 4.00

132 Providing & fixing dial type (100 mm) pressure gaugewith isolation ball valve suitable for working pressureof 250 PSI. Cost shall be inclusive of providing anyshort pieces, nipples, elbows, stainless steel 'U' tube &ball valveetc as required.

each 6.00133 Providing & fixing gun metal single headed fire

hydrant landing valve with flanged inlet, brass spindlecontrolled 63 mm dia female instantaneous outlettype. CI wheel, GM coupling, blank cap, chain, twistrelease type lug & all accessories. Conforming toIS:5290. Including fixing with anchor fastner andflanged tapping from wet riser and providing pressuregauge with gun metal ball valve complete as required.

each 23.00

Page 73: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

134 Providing & fixing non-percolating rubber reinforcedlined (RRL) fire hose pipe (as per IS : 636) of 63 mmdia and 15 metre length. The hose shall be rated forbrust pressure of 35.7 Kg/sqcm. Hose shall becomplete with ISI marked brass male & femalecoupling (IS:903) bound & rivetted to hose pipe withcopper rivets & 1.5 mm copper wire for External firehydrant. each 46.00

135 Providing and Fixing 63 mm dia instantaneous patternbranch short gunmetal pipe, 20 mm dia nozzleconforming to IS 903, suitable for inter connection tohose pipe coupling complete as required.

each 23.00

Page 74: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

136 Providing & fixing Gun Metal fire brigade connection(suction collecting head) consisting of 4 Nos. 63 mmdia instantaneous type male couplings with built-incheck valves, 1 each 150 mm dia sluice valve, (1 each150 mm dia non-return valve) and 150 mm diaflanged outlet complete with bolts, nuts and rubberinsertions as required and as per IS standards.

each 4.00137 Providing & fixing Gun Metal fire brigade suction hose

coupling (draw-out connection) with nut for femalecoupling as per IS standards complete with 100 mmdia GI suction pipe and 100 mm dia foot valve (to beconnected to static tank). Provision of GI drop pipeand foot valve shall be made in all the fire water staticstorage tanks (4 Nos) (GI pipe to be paid separatelythrough appropriate item while cost of foot valve to beincluded).

each 3.00

a 50 mm dia. metre 25.00b 80 mm dia. metre 85.00

139 Providing & Fixing of Installation Control Valve withturbine type automatic alarm gong to be connectedwith control valve, drain & test valve and all othernecessary components as per manufacturer'sspecifications complete as required.

a 150 mm dia. each 2.00140 Providing & fixing brass quartzoid sprinklers (UL

approved) of 15 mm dia size, suitable for sustainingthe pressure on the seat & water hammer effect. Thetype & temperature rating shall be as follows :

a Spray recessed (adjustable) rossette (68°C) sprinklerquick response pendant / upright type. each

11945.00

141 Providing and Fixing electrically operated water flowswitches (Vane type) including tamper switch andaccessories, complete with tap off socket arrangementas required, with potential free contact with 2 eachNONC.

a 150 mm dia. each 51.00142 Supply, installation, testing and commissioning ISI

marked (IS:940) portable chemical fire extinguisher,water (gas pressure) type capacity 9 litres with gunmetal cap and nozzle and complete in all respectsincluding initial fill and wall suspension brackets asrequired as per specifications.

each 21.00

Providing, fixing, jointing, painting with two coats ofsynthetic enamel paint i/c primer coat and testing inposition the for drainage purpose following mediumclass (Class B) MS pipes conforming to IS:1239 cut torequired lengths including all necessary fittings (Allfittings shall confirm to IS:1879 (part 1 to 10) andspecials such as bends, tees, unions, Reducers,flanges & plugs etc. fixing at wall / ceiling levelsupported by clamps, hangers (using anchor fastners)etc. as per specification. Threading / Welding, jointing,and making proper connections, cutting hole in wall /floor / slab and making good the same. PVC pipesleeves suitable higher size shall be providedwherever the pipes are crossing the fire rated walls /floors slab and sealing the sleeves with glasswool inbetween and fire sealent compound at either end allas per Engineer-in-Charge. All hangers, clamps,brackets etc. shall be of galvanized iron unlessspecified otherwise and the supply of the same shallalso be included in rates under this head.

138

Page 75: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

143 Supply, installation, testing and commissioning ISImarked (IS:2878) Fire Extinguisher, Carbon-di-oxidetype capacity 4.5 Kg. Flat base including valve,discharge hose of not less than 10 mm dia, 1M longand complete in all respects including initial fill withCO2 gas conforming to IS:307-1966 and walllsuspension braket as required as per specifications.

each 21.00144 Supply, installation, testing and commissioning ABC

(Powder Type) Fire Extinguisher. Mild Steel CylindersISI marked fitted with pressure indicating gauge,internal tube, squeeze lever type valve fully chargedwith ABC powder (Mono Ammonium Phosphate)pressured by Nitrogen complete in all respectsincluding wall suspension bracket and conforming toIS:1349-1993 as required as per specifications.

a 4 Kg. each 21.00b 9 Kg. each 21.00145 Providing, fixing, testing & commissioning of MS air

cushion tank on top of each riser fabricated from 6mmthick MS plate, 200 mm in diameter and 1.2 m inheight with dished ends fabricated from 8mm thick MSplate with Air release valve with stop cock, flangedinlet connection and drain arrangement with 25mmdia valve, pressure gauge with gun metal stop cockcomplete with all accessories as required andconforming to IS 4736-1968. (The cushion tankshould be suitable for rated working pressure.

each 1.00

Page 76: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

INTELLIGENT ADDRESSABLE FIRE DETECTION & ALARM SYSTEM

FIRE ALARM PANELS

Supply, installation, testing and commissioning of thefollowing as per specifications :

UL Listed Microprocessor based analogue addressable3 Loops fire alarm control panel with minimum 168characters LCD display. each loop of panel shall haveminimum capacity of 250 (125 Detectors + 125Devices) analogue addressable devices, and shall haveprovision for 20% spare capacity. The panel shall beUL 9th Edition listed and shall be in compliance withtechnical specifications.

The panel shall be complete with Integrated 8 channeldigital voice evacuation and 2 ways communicationFire Fighters system capable to supervision of all thespeaker circuits with adequate zone control andaccessories. The system shall be equipped withnecessary Digital Audio Amplifier capable of processingone of 8 audio channels and total wattage as perspeakers mentioned in BOQ with necessaryenclosures. The DAA shall be fully monitored forfault and alarm reporting. The proposed DigitalAmplifiers shall not be rail mounted / dependant onFire Panel CPU for operation. (Failure of Fire Panel CPUshall not result in failure of Amplifier operation).

Tenderer to provide interfacing connectivity (BAC Net/ Modbus gateway) in Fire Panel for integrating with building management system, PA system and Music system (for selected zones) complete as per specification.

Fire Detection & Alarm Control Panel.

147 UL listed Repeater panel for accessing the informationfrom alternate locations. The Repeater Panel shallinclude a minimum of 168 characters, backlit by a longlife, solid state LCD. It shall be equipped withrubberized key pad. The keypad is functional onlywhen an entry is requested by the system. There shallbe fixed and soft keys for functional requirements asper technical specifications.

each 1.00ALARM INITIATING DEVICES, MODULES & CONTROLS :Supplying, installing, testing and commissioning of following items:

UL listed analogue addressable Multi Sensor smokedetector with mounting based LED, Address Switch /electronic way of addressing, complete as per allrequirements of technical specifications & contractsworks.

UL listed analogue addressable Photoelectric smokedetector with mounting based LED, Address Switch /electronic way of addressing, complete as per allrequirements of technical specifications comprising ofbelow :UL Listed Fixed temperature cum rate of rise heatdetector with mounting based LED, Address Switch /electronic way of addressing, as per technicalspecificationsAnalog addressable LPG detector with mounting basedLED, address switch to programme the detectorscomplete as required.

150 Fault Isolators for isolating shorted, dewired and loosecircuits between two successive fault isolators withautomatic resetting arrangement complete asrequired.

each 24.00151 Addressable control/relay modules for Hooters,Fire

pumps, Elevators and Pressurization Fan complete.

each 42.00

149

146

148

each 55.00

each 385.00

each 1.00

Page 77: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

152 Addressable monitor modules for Sprinkler FlowSwitch, Fire doors, magnetic contacts complete.

each 10.00153 UL listed, dual action (push IN-pull DOWN) Flush or

surface mounted Manual Call Point in manufacturersprescribed matching red enamel outlet box completewith key operated test-reset lock. The word FIRE shallappear in front of station as per technicalspecifications. each 25.00

154 Fire Fighter's Telephone Jack for 2 way communicationas per specifications complete

each 8.00155 2 way communication Fire Fighter's Handset.

each 2.00156 Fire panel supervised 70db-84db Ceiling Mounted

multi tap 2 Watt Speaker as specified & same make asof panel. each 285.00

EFFULENT TREATMENT PLANT - ETPA. DESIGN,SUPPLY, INSTALLATION , Testing and commissioning OF EFFLUENT TREATMENT SYSTEM FOR RECYCLING OF EFFLUENT

Nature of influent - Effluent Daily average flow - 20 cum/day Reuse of treated water. Inlet To STPSupply, installation, testing & commissioning of

Screens:2 Nos.Stainless Steel Suitable Sized Manually operated Bar Screen made of SS 304 in RCC screen channel as per following specifications.

Cleaning :- Manual ScreenBar Spacing :- 5 - 6 mmMOC :- Complete in SS 304

Supply, installation, testing & commissioning ofadequate capacities of twin lobe air blower andCoarse air diffusers in Equalisation tank forproviding aeration.(Qty.-1.00 Lot) Make of diffusers : Micro/Eqv.Capacity of blower : 30 m3/hrHead of blower : 5500 mmmwcMake of blowers : Beta/Eqv.

Supplying, installing, testing, commissioningof Centrifugal Soil Scape Filter Feed pumpsComplete in CI body& CI impeller with motor,pressure gauge with isolation cock, Isolationvalve, NRV on delivery line. Isolation valve,strainer at suction. The pump shall be suitablefor 415±10% volts 3 phase AC supply .

Pumps = 02 Nos.(1w + 1s)Flow rate (each) = 2.5 m³/hrHead = 8-10 mSupply, installation, testing & commissioning of

the ecotechnology system complete withOrganotreat™, Specific Plant species, UnderDrain media.(Qty.-2.00 Lot)

Organotreat: specific media for growth of plant and microbial species Make of organotreat: Trans NV tech

Providing and fixing all piping and isolationcontrol valves for making the systemcomplete.(Qty.-1.00 Lot) Providing MFM at inlet of the system.(Qty.-1.00 each)Providing and fixing water meter at outlet of the system. (Qty.-1.00 each)Providing and fixing pH meter at outlet of the system. (Qty.-1.00 each)B. ELECTRICALS

157

Page 78: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Design, fabrication, assembling, wiring, supply,installation, testing and commissioning of motorcontrol centre fabricated out of 14 gauge CRCAsheet steel. Cable gland plates shall be providedon top as well as at the bottom of the panels.Panels shall be treated with all anticorrosiveprocess before painting as per specificationswith 2 coats of red oxide primer and finalapproved shade of powder coated paint. 2 Nos.earthing terminals shall be provided for 3 phase,4 wire, 50 Hz supply system. Panel should becomplete with Isolation push button for everyequipment and auto manual selectionswitches,as per complete Job. (Qty.-1.00 Job).

Note:Realted all SS/MS/CI works such as supply and fixing of handrails, manholes, gratings, grills, vents, footrests and puddle flanges.

Contractor shall ensure submission of detailed GAdrawings (Plan & Section), P & I diagram, schematicdiagram for the above mentioned components andadditional components such as inserts, puddle flanges,vent pipes etc. if so required for the completeautomatic working of the STP and have it approvedby the Engineer-in-Charge.

Effluent Treatment Plant - ETP as described above all

BORE WELL(a)Supplying, installing, testing and commissioningsubmersible type of pump of approved make suitablefor tube well with all necessary standard fittings andaccessories adequate capacity of motor i/c like baseplate, bend, tee etc. and flow control devices, suitablefor well dia 150mm and meeting the followingrequirement all complete as per specification anddirection of Engineer-In-Charge.Discharge - 5 LPS and Head - 110 Meters.

(b) Providing and lowering GI 80mm dia doubleflanged lowering pipe of suitable size for pumpingmachinery as approved by the Engineer-in-charge.Including all C.I specials such as C.I SV, Reflex valveetc. for making connection with the delivery line allcomplete as per specification and direction of Engineer-In-Charge. - 95 metre.

(c ) Supply, Installation, Testing and Commissioningof Pressure Gauge all complete as per specificationsand direction of Engineer-In-Charge .

SEWAGE TREATMENT PLANT - STPA. SEQUENTIAL BATCH REACTOR TECHNOLOGY

Design, supplying, installing, testing & commissioning of Sewage Treatment Plant (SEQUENTIAL BATCH REACTOR TECHNOLOGY) (including all MS work) for the following duty:

Nature of effluent - Domestic Sewage from toilet,kitchen waste water shall be discharged into the STP.Design to take consideration of same.

Daily average flow - 350 Cum / DaypH - 7.5 – 8.5BOD5 - 250 – 400 Mg/LS. Solids - 200 – 450 Mg/LCOD - 400 – 600 Mg/LOil & Grease - 50 Mg / LEffluent discharge standard after treatment

pH - 6.5 – 8.5BOD5 - Less than 10Mg/LS. Solids - Less than 10 Mg/L

159

Job

158

each 4.00

1.00

Page 79: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

COD - Less than 60 Mg/LOil & Grease - Less than 2 Mg / LSewage treatment plant shall include the following items:Grit chamberScreen ChamberSewage equalization tank / sumpReactor Tank - 2 nos.Supernatant TankSludge Holding TankFiltration through MGF & ACFUV UnitAir Blowers, Pumps & equipmentPiping, valves etcElectrical Panel & Cabling1. Supply, installation, testing & commissioning of 2Nos Stainless Steel Perforated, Corrugated Bar Screenwith suitable lifting arrangement (size 1000 mm widex 600 mm high approx). (Qty-1 set)

2. Constructing Grease Trap of suitable size withminimum of 1200 liquid depth in brick work of class 75with cement mortar 1:6 (1 cement:6 coarse sand),inside plastering 16 mm thick with cement mortar 1:3(1:cement:3 coarse sand) with floating coat of neatcement and rough plaster on outside. Including SSbucket as per detail to collect the grease. RCC top slabwith 500 mm dia medium duty manhole covers withframe (weight of covers 58 Kg & weight of frame 58Kg), necessary 150 mm thick foundation concrete1:2:4 (1 Cement:2 coarse sand:4 Aggregate). (Qty-1no)

3. Supply of MS hot dip galvanized puddle flanges inaccordance to BS:10 table D as required to beprovided (in the structural slab and wall) of variousdiameters. Puddle flanges shall be provided for all thestructural component of the STP. The installation ofthe puddle flanges shall be carried out by the Civilcontractor in accordance to the Civil GA drawing (to beprepared by the STP contractor) at the required levels& position; under the supervision of the STPcontractor.(Qty-15 Nos.)

4. Supply of plastic manhole step/foot rest (@ 300mm c/c) with polypropelene compound injectionmolded around 12 mm dia (Fe-415) steel reinforcingbar. Provision of the foot rest is envisaged in varioustanks/ components of the STP for the purpose ofaccessability. The installation of the foot rest shall bedone by the civil contractor as per civil GAdrawing.(Qty-80 No.)

5. Supply, installation, testing & commissioning of 10mm thick MS chequered plate rectangular manholecover with frame for the feasibility of access in thetank with locking arrangement.

Size : 600 x 900 (Qty-6.00 No.)6. Supply of vent pipes of 100 mm dia with mosquitoproof grating suitable for the ventilation purpose of thevarious tanks.(Qty-8.00 Nos.)

7. Supply, installation, testing & commissioning ofdisplacer type level switch for automatic operation ofthe system with high / low level alarm complete withauxillary NO/NC contacts for each tank. (Qty-6.00No.)

8. Supply, installation, testing & commissioning ofFloat & Board type level indicator with isolation valveat top / bottom, & making the installationcomplete.(Qty-1.00 No.)

Page 80: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

9. Supply, installation, testing & commissioning ofnon clogging type submersible pumps complete withall accessories, motor of required capacity. Deliveryheader with isolation valve, pressure gauge ondelivery line with isolation cock, level controller (withwiring) to control the level of sump automatically.Provison shall be kept to run both pumpssimultaneously in case of emergency. Pumps shallhave following duty:

9.1 EQT Submersible Sump Pumps for EQT-considering 6 cycles (2 Nos. 1 working & 1 standby)

Flow rate (each) = 30 cum/hrHead = 12 to 15 MtrMOC : CI9.2 Solid handling size for this pump shall be 35-40 mmSludge disposal pump (2 Nos - 1 working + 1 Standby)Flow rate (each) = 9.0 LPSHead = 15 MtrMOC : CI9.3 Solid handling size for this pump shall be 15 mm

Plant room sump pump (2 Nos - 1 working + 1 Standby)

Flow rate = 6.0 LPSHead = 15 Mtrs MOC : SS(Solid handling size for this pump shall be 15 mm).

Cost shall be inclusive of PVC flexible Hose pipe ( forpiping submeged in effluent) with MS epoxy piping(for piping non-submerged in effluent)

Provision of guide ropes to guide submersible pumpfrom upper level to operational level in sump basinwith channels / angle section of MSEP shall be madeby the STP contractor.

10. Air diffusion system shall include the following:

10.1 2 Nos. twin type rotary air blowers (1W + 1S)capable of delivering 200 cum/hr of free air at 0.6kg/cm2 driven through “V” belt or directly coupledthrough flexible coupling to a TEFC motor of suitableHP Suitable for 415 ± 10% volts, 3 phase, 50 cyclesA/C supply. 10.2 Air piping shall comprise of pipes droppers /laterals with MS (epoxy coated) Header complete withall fittings such as tees, crosses, plugs, sockets,elbows, reducers, supports & clamps, puddle flangesetc cutting chases & making good. Contactor to submitdetailed P & I indicating their proposal.(Qty.-1.00 Lot)

10.3 Non clog type air dispersion system capable ofhandling 3-5 cfm of air with oxygen transfer efficiencyof 3-4% per/meter water depth. Air dispersion gridshall be assembled in modular form so that they canbe replaced / repaired easily from plat form at the top.(Imported fine bubble membrane diffusers).(Qty.-1.00Lot)

11. Bronze Ball valve and air dispersion grid asrequired for STP as described above.(Qty.-1.00 Lot)

Note : Air dispersion system shall be provided forSewage Sump, aeration tank and Sludge HoldingTank.

12. Providing and fixing all piping (as describedbelow) and isolation control valves for making thesystem complete.

SS 304 : Submerged air pipingMS Epoxy : Air piping & pumped effluent riser (non-submerged)

Page 81: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

PVC piping : Pumped effluent (submerged) & tank overflow pipe line GI (Heavy) : Interconnecting pipe line after delivery header of pump/ filter.

13. Supply, installing, testing & commissioning ofultravoilet dis-infection unit. The unit shall haveover 99.9 % bacterial reduction from inlet to outlet.The dis-infection chamber shall be constructed of SS316L on all welted parts. The UV lamp shall be of lowpressure mercury vapour type with hard glassenclosure, the sockets shall be water tight & vibrationresistant. The lamp life shall be rated for 6000 hours.The unit shall be complete with temperature safetycontrol, lamp out alert circuit & UV radiometer with 4– 20 mA output.

The UV unit shall have with reactor, cabinet housing,cabinet cooling, treatment chamber, electrical panel,temperature safety control, lampout alert, UVradiometer along with UV monitoring system and UVmonitoring readout panel. The UV Dosage should be >60,000 uW – Sec / sq.cm. The lamps should beselected based upon the flow requirement ofrespective unit.

13.1 Flow Rate : 17.5 Cu-m / Hr.(Qty.-1.00 No)14 Supplying, installing, testing & commissioningof hypochlorite solution doser comprising of 200Litres capacity FRP tank with inlet / outlet connection,piping & valves alongwith metering (0-12 lph) pumpfor dosing. (Qty.-1.00 No)

15. Supplying, installing, testing & commissioning ofFloating type SS304 Decanter System with all requiredaccessories in Reactor tanks. (Qty.2 No)

16. Supply, installation, testing and commissioningof PLC based Reactor controller in Reactor tank tocontrol the cycle of Reactor system based on time &Level based flow measurment inbuilt in the controller.(Qty.-2 No.)

17. Supplying, installing, testing & commissioning ofhorizontal centrifugal filter feed water pumps CIHead & Base, Bronze Impeller along with motor,pressure gauge with isolation cock, Isolation valve,NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Mechanical seal, suitable vibrationelimination pads of approved design, drain pipe withvalve (25 dia) for the pump. The pump shall besuitable for 415±10% volts 3 phase AC supply.

17.1 Filter Feed Pumps: (1 working+ 1 Standby)

Capacity : 5.0 LPS each

Head : 30 MRPM : 2900 17.2 Irrigation pumps: (1 working+ 1 Standby)-

Capacity : 2.0 LPS eachHead : 30 MRPM : 2900

18. Providing, fixing, testing & commissioning ofvertical MSEP filter with adequate dirt holdingcapacity. Fabricated from MS sheet as permanufacturer's specifications complete with intitialcharge filter media including painting inside with twocoats of non toxic epoxy and with one coat of zincchromate two coats of synthetic enamel paint outside.Including concrete foudation with cement plastercomplete as required. The filter shall also be providedwith set of internals for raw water inlet and bottomcollecting system. Complete with frontal piping(heavy) and butterfly valves designed on 1.50 m / secvelocity.

Page 82: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

18.1 Filter for Domestic Water services.(Qty-1.00 no.)Filteration Rate 20000L/Sqm/HrFlow Rate : 5.0 LPS18.2 Activated Carbon Filter :(Qty-1.00 no)Filteration Rate 14000L/Sqm/HrFlow Rate : 5.0 LPS19. Supply, installation, testing and commissioningof Hydraulic filter press of Suitable Capacity with CIframe, PP plates complete with filter cloth completewith Filter press feed pump (Screw Type) – 2 No. (1working + 1 standby) with 1 No. standby stator,interconnecting piping and poly dosing system.

20. Supply, installation, testing & commissioning ofElectro-magnetic type Flow Meter at inlet of reactortanks of 100 mm size. (Qty-2.00 No)

21. HYDRO-PNEUMATIC SYSTEMSupply, Installation, Testing And Commissioning OfCompact Self Contained Skid MountedHydropneumatic System As Follows:

a. Vertical, In-Line, Multisage, centrifugal pumps withSS-304 casing and impeller and SS-316 shaft, CI base& head TEFC motor (with mechanical seal)

(Contractor to submit performance curves andtechnical catalog of the proposed model for review &information)

The pump shall be selected for performance at bestefficiency point. However, the pump selection shall besuitable for performance with set point @ + 20% of therated head.

b. External Pump mounted or wall mountedmicroprocessor PID controller and frequency inverterintegrated in a single body or as separate componentswith pressure sensor transmitter minimum two linedLCD display, diodes to indicate pump ready, pumprunning and fault and capable to communicate withother controllers following MODBUS-RTU or BACNETClass-2 protocall through RS485 port. System shouldbe capable to compensate for frictional losses at lowerflows. All alarms should be displayed in the controller.System should be equiped with dry running protection.

c. Complete (Skid mounted wall mounted / floormounted) electrical control panel comprising of allaccessories such as PLCs, pressure switches, pressuretransducers, control wiring ,single VFD and any othernecessary imports etc.

d. Precharged diaphram pressure vessel with foodgrade membrane, charging connection, connected tooutlet header with necessary flanges, gaskets,isolating valves, nuts/bolts etc complete.

e. Set of accessories such as pressure switches,pressure transducers, inter connecting power andcontrol cabling etc. complete.

f. Accessories like pressure gauge, MS base frame(Synthetic enamel painted over a coat of primer).

g. GI suction and delivery header with flanges for inletconnection, common outlet header with flanges foroutlet connections as required, and inter connectingpiping with flexible connections, eccentric typereducers etc. all necessary indigenous accessories asrequired to complete the installation.

21.1 Flushing hydropneumatic system as follows:No. of pumps -2 (1 Working + 1 Standby)Water Flow Rate 7.0 LPS each Purpose : OHT Filling for phase-1Head 80 MRPM 2900

Page 83: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

22. Providing & fixing on line Electro magnetictype flow meter cum Totaliser for Monitoring thetotal flow, Flow rate. etc. Including electrical wiringfrom panel to flow meter. Complete with all type ofPlumbing & Electrical connections, accessories,wiring, conduits & supports complete with all respect.The signal from read out shall be 4-20 m.amps to bereceived on BAS.(Qty-1 no.)

23. Providing & fixing level controllers, pressureswtich and transmitters for water pumps tostart/stop the pump at set level. Including wiring,cabling from pump to panel & all other accessories asrequired to operate the system automatically.(Qty-4No)

24. Providing & fixing on line pH meter digitaltype for Monitoring the online pH after Tertiarytreatmnent & before disposal. Including electricalwiring from panel to flow meter. Complete with alltype of Plumbing & Electrical connections, accessories,wiring, conduits & supports complete with allrespect.(Qty-1 no.)

25. Approval from pollution board at initial &various other stages of works including preparation ofreport / drawings as per pollution board requirement,testing & commissioning. Contractor shall include thecost of all chemicals consumed during testing &commissioning and the cost of such items of workswhich are not explicitly mentioned above, but aremendatory to have pollution board approval.(Qty-1Job)

B. ELECTRICAL INSTALLATION FOR SEWAGE Design, fabrication, assembling, wiring, supply,installation, testing and commissioning of motorcontrol centre shall be fabricated out of 14 gaugeCRCA sheet steel in form in 3b formation withreinforcement of suitable size angle iron, channel ‘T’sections irons and /or flats wherever necessary. Cablegland plates shall be provided on top as well as at thebottom of the panels. Panels shall be treated with allanticorrosive process before painting as perspecifications with 2 coats of red oxide primer andfinal approved shade of powder coated paint. 2 No.earthing terminals shall be provided for 3 phase, 4wire, 50 Hz supply system. Lifting hooks shall also beprovided in case of large panels. Approval shall betaken for each panel before fabrication. CadmiumPlated hardware shall be used in fabrication of panels.Quoted rates shall inclusive of cables, cable trays,control cabling, earthing (in accordance tospecification) with earthing from panel to each motor /equipment.

MCC –1 (Sewage Treatment Plant)

Incoming200 amps TPN MCCB with the following accessories:a. 0-415 volts 96 x 96 mm square voltmeter with selector switch shall be protected by 2 amps TP MCB. 1 Setb. 0-500 amps 96 x 96 mm square ammeter with selector switch and 200/5 amps 10 VA CL:1 CTs. 1 Setc. Phase indicating lamps shall be protected by 2 amp SP MCB-3 SetBus Bar250 amps TPN (25 KA) aluminium bus bar with heat shrinkable insulation sleevesOutgoingsa. 2 No. suitable rating MPCB for 10.0 KW DOL starterand outgoing feeder to EQT effluent transfer pumpsmotor - Main (including 1No. standby). Eachcompartment shall contain auto / manual selectorswtich and indicating / pushbutton lamps with MCB forON / OFF / TRIP of motor.

Page 84: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

b. 3 No. suitable rating MPCB for 5.0 KW direct on linestarter and outgoing feeder to air blowers (including 1no. standby). Each compartment shall containauto/manual selector switch and indicating lampswith MCB’s for ‘ON/OFF/TRIP' status of motor

c. 2 No. suitable rating MPCB for 3.0 KW direct on linestarter and outgoing feeders to sludge disposal pump(including 1 no. standby). Compartment shall containauto/manual selector switch and indicating lampswith MCB’s for ‘ON/OFF/TRIP’ status of motor

d. 2 No. suitable rating MPCB for No. 4.0 KW direct online starter and outgoing feeders to filter feed pumpincluding future (including 1 no. standby). Eachcompartment shall contain auto/manual selectorswitch and indicating lamps with MCB for‘ON/OFF/TRIP’ status of motor

e. 2 No. suitable rating MPCB for No. 3.0 KW direct online starter and outgoing feeders to irrigation waterpump (including 1 no. standby). Each compartmentshall contain auto / manual selector switch andindicating lamps with MCB for ‘ON/OFF/TRIP’ status ofmotor

g. 2 No. suitable rating MPCB for 2.2 KW direct on linestarter and outgoing feeders to Filter press.Compartment shall contain auto/manual selectorswitch and indicating lamps with MCB’s for‘ON/OFF/TRIP’ status of motor

h. 2 No. suitable rating MPCB for 3.0 KW direct on linestarter and outgoing feeders to plantroom sump pump(including 1 no. standby). Compartment shall containauto/manual selector switch and indicating lampswith MCB’s for ‘ON/OFF/TRIP’ status of motor

j. 1 No. suitable rating TPN MCB for 5.0 HP outgoingfeeders to flushing water hydropneumatic for Phase 1

k. 2 No. suitable rating MPCB for No. 15 KW star deltastarter and outgoing feeders to axial flow fan. Eachcompartment shall contain auto/manual selectorswitch and indicating lamps with MCB for ‘ON / OFF /TRIP’ status of motor.l. 1 Nos. suitable rating MPCB for 3.0 KW direct on linestarter and outgoing feeders to submersible mixer.Compartment shall contain auto/manual selectorswitch and indicating lamps with MCB’s for‘ON/OFF/TRIP’ status of motorm. 2 Nos. suitable rating MPCB for 5.0 KW direct online starter and outgoing feeders to floating typedecanter. Compartment shall contain auto/manualselector switch and indicating lamps with MCB’s for‘ON/OFF/TRIP’ status of motor

n. Spare MCB’s of following capacities:i. 20 amps TPN MCB’s2 Nos.ii 32 amps TPN MCB’s2 Nos.Note : All MCCB's to be suitable for motor duty andshall be of 25 KA breaking capacity.

Provision shall be made for providing potential freecontacts to all pumps starters for connection tobuilding automation system.

MCC –1 for STP as described above ( Qty.- 1 Nos.)

Note1: Contractor shall ensure submission of detailedGA drawings (Plan & Section), P&I diagram, schematicdiagram for the above said component and additionalcomponent if so required for the complete working ofthe STP for the full capacity.

Page 85: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

Note2: Contractor to note that the suction header isrequired to have inlet connection from the PuddleFlange @ water tanks and to the pump suction.Provision of delivery header is required to have outletconnection from the pumps. Suitable outlet flangesfrom the delivery mainfold / header shall be providedas required.

Sewage Treatment Plant -STP( Sqential Batch Reactor Technology) as described all above

Main Distribution Board for STP: Supply,Installation, Testing & Commissioning , cubicle typebody made out of 2mm thick CRCA sheet,totallyenclosed, IP 42, floor mounted with channel baseframe, dust and vermin proof, indoor,compartmentalised, suitable for operation on 3 phaseand neutral, 415 V, 50Hz AC system with extensiblebusbars on both sides, making interlockingarrangement including control wiring with 2.5 sq mmsize wires/cable, interconnection, duly powder coatedpainting etc. including supply & installation offollowing switchgears,metering instruments andaccessories as per specifications.

INCOMER1 No. 150 Amp four pole Moulded Case Circuit Breaker(Ics value 35 KA) with built in thermal based releaseunit with adjustable setting .BUSBARS150Amp TPN busbars of high conductivity electrolyticquality aluminium alloy.

INSTRUMENTS

1 No. digital multifunction meter (Ammeter + Voltmeter) for 3 phase, 4 wire operation as per specification.1 Sets of RYB phase indicating lamps controlled by 2 amp MCB.

OUTGOINGa. 1 Nos. 40 amps TP MCCB (Ics value 35 KA)outgoingfeeder to 1 no. Domestic Water pump.

b. 2 No. MPCB with (Ics value 35 KA) DOL starter ofsuitable rating for outgoing feeder to Filter feed pumpmotor 2 no. 5 HP(1working + 1Stand by). Eachcompartment shall contain direct & analogue typeAmmeter , auto / manual selector swtich andindicating / pushbutton lamps with MCB for ON / OFF /TRIP of motor.

c. 4 No. MPCB with (Ics value 35 KA) DOL starter ofsuitable rating for outgoing feeder to Bore well pumpmotor 4 no. 15 HP (2working + 2Stand by). Eachcompartment shall contain direct & analogue typeAmmeter , auto / manual selector swtich andindicating / pushbutton lamps with MCB for ON / OFF /TRIP of motor.

d. 4 Nos. MPCB with (Ics value 35 KA) DOL starter ofsuitable rating for outgoing feeder to Sump pumpmotor 4 no. 3 HP ((2working + 2Stand by).Eachcompartment shall contain direct & analogue typeAmmeter , auto / manual selector swtich andindicating / pushbutton lamps with MCB for ON / OFF /TRIP of motor.

No 1.00160

Page 86: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

S. No.

Description of Item Unit Quantity Rate in Fig.( Rs.)

Rate in Words ( Rs.)

Amount (Rs.)

e. 8 Nos. MPCB with (Ics value 35 KA) DOL starter ofsuitable rating for outgoing feeder to stormwaterdrainage sump pump motor 8 no. 2 HP (4working +4Stand by). Each compartment shall contain direct &analogue type Ammeter , auto / manual selectorswtich and indicating / pushbutton lamps with MCB forON / OFF / TRIP of motor.

Note:

All breakers shall be mechanical interlocked with suitable accessories.

Separate neutral link shall be provided in all 3 Pole feeders.

All breakers breaking capacities shall be ICU=ICS No 1.00

Total Cost of NON Schedule items(Civil) of

Schedule-B

Page 87: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

SUB HEAD (A): ELECTRICAL WORKSCIRCUIT CUM POINT WIRING

1 Supply, installation, testing and commissioning of flush mounted outlets wired to T 568 A or Bwith British style faceplace. The plastic shall be high impact, flame-retardant, UL ratethermoplastic. Dust cover/ blank shall be provided to protect unused fa

a Single outlet faceplate with RJ-45 jack Each 652.00

2Supply, installation, testing and commissioning of 4 pair Category 6 LAN cable consisting of 24AWG solid copper conductors and as per the specification.

a The cable should have flexibleJacket and ripcord for easy stripability metre 7,000.00

Notes:- The rate shall also include the following:

Providing and fixing junction boxes with covers including painting.

Effecting adequate and proper connections at temetreinations.

Providing all fixing accessories such as clamping devices nuts, bolts and screws.

Excavation laying of cable filling of sand, brick protection, back filling of earth, watering,ramming and making good.

Wherever the cables are of aluminium and bus bars of copper bimetallic lugs shall be used.

All cable shall be laid with one diameter gap.

All cables shall be IS approved.

Fire retardant paint one meter on both side of wall penetration and at temetreination as perspecifications.

Buried LT cables to be laid atleast 750 mm below ground.

All cut-outs/ Sleeves shall be sealed with fire retardant sealant as per specification.

CABLES, MAINS AND SUB MAINS3 Supplying of following 1100 volt grade XLPE insulated PVC inner sheathed and HR PVC outer

sheathed aluminium conductor ametreoured cables as per specification.

a 3.5 Core 300 Sq.mm metre 22.00

b 3.5 Core 185 Sq.mm metre 195.00

c 3.5 Core 150 Sq.mm metre 350.00

d 3.5 Core 120 Sq.mm metre 165.00

e 3.5 Core 95 Sq.mm metre 270.00

f 3.5 Core 70 Sq.mm metre 470.00

g 3.5 Core 50 Sq.mm metre 140.00

h 3.5 Core 35 Sq.mm metre 800.00

i 4 Core 25 Sq.mm metre 600.00

j 4 Core 16 Sq.mm metre 60.00

Name of the work :Construction and Development of Agri-Food Cluster Campus of National Agri Food Biotechnology Institute(NABI) at Mohali(Punjab).

NON SCHEDULE ITEMS (ELECTRICAL) SCHEDULE-D

Page 88: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

4 Supplying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cableas per specification in existing trenches, cable trays ducts over bed of sand, clamped includesanchor fastners to wall with suitable clamps, saddles fixing bolts including connecting testing andcommissioning.

a 4 Core 10 Sq.mm metre 1,500.00

b 4 Core 6 Sq.mm metre 490.00

c 4 Core 4 Sq.mm metre 990.00

d 3 Core 6 Sq.mm metre 1,445.00

e 3 Core 4 Sq.mm metre 54.00

f 2 Core 2.5 Sq.mm. Control Cable (Dual Metering) metre 320.00

5Cable end termination of the following PVC insulated sheathed PVC/XLPE aluminium / copperconductor armoured cables of 1100 volt grade including supplying and fixing of crimpingaluminium lugs, double compression glands with earthing facility at both ends of cables etc.complete as required.

a 4 Core 6 Sq.mm metre 24.00

b 4 Core 4 Sq.mm metre 40.00

c 3 Core 6 Sq.mm metre 56.00

d 3 Core 4 Sq.mm (Copper Unarmoured Cable) metre 20.00

e 2 Core 2.5 Sq.mm. Control Cable (Dual Metering) metre 26.00

6 Providing and laying 1.6 MM thick GI factory fabricated raceways in partition of the followingsizes including providing removable 3 mm thick GI cover knock out holes and fixing accessoriesearthing with 8 SWG copper earth wire complete required including floor wall supports, bends,access boxes and tap off boxes as per specification and cross over as per site requirement.

a 300 mm wide x 40 mm deep raceway metre. 342.00

b 250 mm wide x 40 mm deep raceway metre. 176.00

c 200 mm wide x 40 mm deep raceway metre. 242.00

d 150 mm wide x 40 mm deep raceway metre. 232.00

e 100 mm wide x 40 mm deep raceway metre. 275.00

fProviding and fixing of 350 x 350 x 40 mm deep (Nominal size) wall junction box includingproviding 3 mm thick GI steel cover required as per specification. metre. 50.00

gProviding and fixing of 250 x 250 x 40 mm deep (Nominal size) wall junction box includingproviding 3 mm thick GI steel cover required as per specification. metre. 40.00

hProviding and fixing of 200 x 200 x 40 mm deep (Nominal size) wall junction box includingproviding 3 mm thick GI steel cover required as per specification. metre. 40.00

iProviding and fixing of 150 x 150 x 40 mm deep (Nominal size) wall junction box includingproviding 3 mm thick GI cover required as per specification. metre. 40.00

Page 89: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

MAIN DISTRIBUTION PANEL/ SUB DISTRIBUTION PANEL/ METER BOARD PANEL

7 Design, fabrication, assembling, wiring, testing, supply, forwarding to site, unloading, shifting tolocation, inspection, installation, testing and commissioning of Main distribution panels/ sub-distribution panels/ Meter Board Panels, fabricated out of 14 gauge CRCA sheet steel in cubiclefometreation, compartmentalized, from 3b construction, free standing floor mounted, dust andvemetrein proof with reinforcement of suitable size angle iron, channel, `T’ sections and/ or flatswherever necessary. 16 gauge CRCA sheet steel shall be used for final distribution panels. 3 mmthick cable gland plates shall be provided on top as well as at the bottom of the panels. Panelsshall be treated with all anticorrosive process before powder coating as per specifications andfinal approved shade. 2 each earthing temetreinals shall be provided for all distribution panels.Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall alsobe provided in case of large panels. Approval shall be taken for each panel in the fometre of shopdrawings before fabrication.

Galvanised hardware with zinc passivation shall be used in fabrication of panels.

MDB-9

Incoming

1 each 800 Amps TPN manually draw out type Air Circuit Breaker (Icu = Ics) with built inmicroproccessor based realease for short circuit, over current, earth fault protection withadjustable settings, ON/ OFF/ Trip indication lamp including control MCB's with fuse and withfollowing accessories as per specifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 800/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars1000 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 125 Amps TPN MCCB - 1 eachiii. 100 Amps TPN MCCB - 3 eachiv. 63 Amps TPN MCCB - 8 eachSpare100 Amps TPN MCCB - 2 eachNotes: -i. All MCCB's shall be of 35 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.MDB-9 as described above Set. 1.00

8 SDB-9.1,10.1&11.1 Incoming1 each 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:VAF digital electronic meter with inbuilt selector switch and 60/ 5 Amps 15 VA, CL 1 CTs . -1 Set

Phase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars150 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing9 each of 32 Amps DP MCB complete with all accessories including wiring etc. as required as persingle line diagram.

Spare

Page 90: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

32Amps DP MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-9.1,10.1&11.1 as described above Set. 3.00

9 SDB-9.2 Incoming1 each 125 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 120/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 100 Amps TPN MCCB - 1 eachii. 32Amps 4P MCB - 2 eachiii. 40 Amps 4P MCB - 3 eachSpare40 Amps 4P MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-9.2 as described above Set. 1.00

10 SDB-9.3 Incoming1 each 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 100/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 63 Amps 4P MCB - 2 eachii. 32Amps 4P MCB - 3 eachiii. 40 Amps 4P MCB - 3 eachSpare40 Amps 4P MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-9.3 as described above Set. 1.00

Page 91: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

11 SDB-9.4 Incoming1 each 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 100/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 63 Amps 4P MCB - 3 eachii. 32Amps 4P MCB - 2 eachiii. 40 Amps 4P MCB - 2 eachSpare40 Amps 4P MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-9.4 as described above

Set. 1.00

12 SDB-9.5 Incoming1 each 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 100/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 32Amps 4P MCB - 3 eachii. 25 Amps 4P MCB - 1 eachiii. 40 Amps 4P MCB - 2 eachSpare40 Amps 4P MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-9.5 as described above Set. 1.00

13 MDB-10 Incoming1 each 1000 Amps TPN manually draw out type Air Circuit ABreaker (Icu = Ics) with built inmicroproccessor based realease for short circuit, over current, earth fault protection withadjustable settings, ON/ OFF/ Trip indication lamp including control MCB's with fuse and withfollowing accessories as per specifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 1000/5 Amps 15 VA, CL 1 CTs . - 1SetPhase indicating light shall be protected by 2 Amps SP MCB's with fuse - 6 SetsBus Bars - 1

Page 92: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

1250 Amps TPN Aluminiun bus bars with heat coloured shrinkable insulation sleeve. - 1 Set

Outgoingi. 200 Amps TPN MCCB -1 eachii. 160 Amps TPN MCCB -3 eachiii. 63 Amps TPN MCCB -3 eachii. 125 Amps TPN MCCB -2 eachSparei. 160 Amps TPN MCCB -1 eachii. 63 Amps TPN MCCB -1 eachNotes:-i. All MCCB's shall be of 35 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity. MDB-10 as described as above.

Set. 1.00

14 SDB-10.2 Incoming1 each 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 160/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 100 Amps TPN MCCB - 2 eachi. 63 Amps TPN MCB - 2 eachiii. 40 Amps 4P MCB - 2 eachiv. 32 Amps 4P MCB - 1 eachSpare40 Amps 4P MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-10.2 as described above Set. 1.00

15 SDB-10.3 Incoming1 each 200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:VAF digital electronic meter with inbuilt selector switch and 200/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars300 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 125 Amps TPN MCCB - 1 eachi. 100 Amps TPN MCCB - 1 eachiii. 40 Amps 4P MCB - 2 eachiv. 32 Amps 4P MCB - 1 eachSpare

Page 93: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

40 Amps 4P MCB - 1 each32 Amps 4P MCB - 1 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-10.3 as described above Set. 1.00

16 SDB-10.4Incoming1 each 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 160/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 100 Amps TPN MCCB - 3 eachiii. 63 Amps 4P MCB - 1 eachiii. 40 Amps 4P MCB - 1 eachiv. 32 Amps 4P MCB - 1 eachSpare63 Amps 4P MCB - 1 each40 Amps 4P MCB - 1 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-10.4 as described above

Set. 1.00

17 SDB-10.5Incoming1 each 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 160/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 100 Amps TPN MCCB - 2 eachiii. 63 Amps 4P MCB - 2 eachiii. 40 Amps 4P MCB - 1 eachiv. 32 Amps 4P MCB - 1 eachv. 25 Amps 4P MCB - 1 eachSpare40 Amps 4P MCB - 1 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.

Page 94: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

SDB-10.5 as described aboveSet. 1.00

18 MDB-11Incoming1 each 1600 Amps TPN manually draw out type Air Circuit Breaker (Icu = Ics) with built inmicroproccessor based realease for short circuit, over current, earth fault protection withadjustable settings, ON/ OFF/ Trip indication lamp including control MCB's with fuse and withfollowing accessories as per specifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 1600/5 Amps 15 VA, CL 1 CTs . - 1SetPhase indicating light shall be protected by 2 Amps SP MCB's with fuse - 6 SetsBus Bars - 12000 Amps TPN Aluminiun bus bars with heat coloured shrinkable insulation sleeve. - 1 Set

Outgoingi. 400 Amps TPN MCCB -1 eachii. 200 Amps TPN MCCB -5 eachiii. 160 Amps TPN MCCB -1 eachiv. 63 Amps TPN MCCB -3 eachSparei. 160 Amps TPN MCCB -1 eachii. 63 Amps TPN MCCB -1 eachNotes:-i. All MCCB's shall be of 35 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity. MDB-11 as described as above. Set 1.00

19 SDB-11.2Incoming1 each 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 400/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars500 Amps TPN Aluminium bus bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 160 Amps TPN MCCB - 2 eachii. 100 Amps TPN MCCB - 3 eachiii. 63 Amps 4P MCB - 1 eachiv. 40 Amps 4P MCB - 1 eachv. 32 Amps 4P MCB - 2 eachSparei. 63 Amps 4P MCB - 1 eachii. 40 Amps 4P MCB - 1 eachNotes: -

Page 95: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-11.2 as described above Set. 1.00

20 SDB-11.3 & SDB-11.4Incoming1 each 200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 200/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars300 Amps TPN Aluminium bus bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 160 Amps TPN MCCB - 1 eachii. 100 Amps TPN MCCB - 2 eachiii. 63 Amps 4P MCB - 2 eachiv. 40 Amps 4P MCB - 1 eachv. 32 Amps 4P MCB - 1 eachSparei. 63 Amps 4P MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-11.3 & 11.4 as described above

Set. 2.00

21 SDB-11.5Incoming1 each 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:VAF digital electronic meter with inbuilt selector switch and 160/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bus bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoingi. 160 Amps TPN MCCB - 1 eachii. 100 Amps TPN MCCB - 1 eachiii. 63 Amps 4P MCB - 1 eachiv. 40 Amps 4P MCB - 2 eachv. 32 Amps 4P MCB - 1 eachvi. 25 Amps 4P MCB - 1 eachSparei. 63 Amps 4P MCB - 1 eachii. 40 Amps 4P MCB - 1 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.SDB-11.5 as described above

Set. 1.00

Page 96: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

22 MDB-11.1 (UPS)Incoming200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessor basedrelease for short circuit, over current, earth fault protection with adjustable setting, ON/ OFF/Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:- 3 each

VAF digital electronic meter with inbuilt selector switch and 200/ 5 Amps 15 VA, CL 1 CTs . -3SetPhase indicating light shall be protected by 2 Amps SP MCB's - 9 SetBus Bars500 Amps TPN Cu Bus bars with heat coloured shrinkable insulation sleeve - 1 SetOutgoingi. 63 Amps TPN MCCB - 8 eachii. 32 Amps DP MCB - 4 eachSparei. 63 Amps TPN MCCB - 2 eachii. 32 Amps DP MCB - 1 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.MDB-11.1 as described above

Set. 1.00

23 MDB-10.1 (UPS)Incoming125 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessor basedrelease for short circuit, over current, earth fault protection with adjustable setting, ON/ OFF/Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:- 2 each

VAF digital electronic meter with inbuilt selector switch and 125/ 5 Amps 15 VA, CL 1 CTs . -2SetPhase indicating light shall be protected by 2 Amps SP MCB's - 6 SetBus Bars300 Amps TPN Cu bars with heat coloured shrinkable insulation sleeve - 1 SetOutgoingi. 63 Amps TPN MCCB - 8 eachii. 32 Amps DP MCB - 4 eachSparei. 63 Amps TPN MCCB - 2 eachii. 32 Amps DP MCB - 1 eachNotes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.MDB-10.1 as described above

Set. 1.00

24 MDB-9.1 (UPS)Incoming63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessor basedrelease for short circuit, over current, earth fault protection with adjustable setting, ON/ OFF/Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:- 2 each

VAF digital electronic meter with inbuilt selector switch and 60/ 5 Amps 10 VA, CL 1 CTs . -2 Set

Phase indicating light shall be protected by 2 Amps SP MCB's - 6 SetBus Bars

Page 97: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

200 Amps TPN Cu bars with heat coloured shrinkable insulation sleeve - 1 SetOutgoingi. 40 Amps 4P MCB - 8 eachii. 32 Amps DP MCB - 4 eachSparei. 32 Amps DP MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.MDB-9.1 as described above

Set. 1.00

25 MDB-9.2 (UPS-Emergency)Incoming63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessor basedrelease for short circuit, over current, earth fault protection with adjustable setting, ON/ OFF/Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:- 2 each

VAF digital electronic meter with inbuilt selector switch and 60/ 5 Amps 15 VA, CL 1 CTs . -2 Set

Phase indicating light shall be protected by 2 Amps SP MCB's - 6 SetBus Bars100 Amps TPN Cu bars with heat coloured shrinkable insulation sleeve - 1 SetOutgoing32 Amps DP MCB - 8 eachSpare32 Amps DP MCB - 4 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.MDB-9.2 as described above

Set. 1.00

26 Design, fabrication, assembling, wiring, testing, supply, forwarding to site, unloading, shifting tolocation, inspection, installation, testing and commissioning of Main distribution panels/ sub-distribution panels/ Meter Board Panels, fabricated out of 14 gauge CRCA sheet steel in cubicleformation, compartmentalized, from 3b construction, free standing floor mounted, dust andvermin proof with reinforcement of 15 size angle iron, channel, `T’ sections and/ or flatswherever necessary. 16 gauge CRCA sheet steel shall be used for final distribution panels. 3 mmthick cable gland plates shall be provided on top as well as at the bottom of the panels. Panelsshall be treated with all anticorrosive process before powder coating as per specifications andfinal approved shade. 2 No. earthing terminals shall be provided for all distribution panels.Panels shall be 15 for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also beprovided in case of large panels. Approval shall be taken for each panel in the form of shopdrawings before fabrication. Galvanised hardware with zinc passivation shall be used infabrication of panelsMDB-1 Tower 27A & MDB-2 Tower 29Incoming1 No. 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased realease for short circuit, over current, earth fault protection with adjustable settings, ON/OFF/ Trip indication lamp including control MCB's with fuse and with following accessories as perspecifications & SLD: VAF digital electronic meter with inbuilt selector switch and 400/5 Amps 15 VA, CL 1 CTs . - 1SetPhase indicating light shall be protected by 2 Amps SP MCB's with fuse - 6 SetsBus Bars - 1

500 Amps TPN Aluminiun bus bars with heat coloured shrinkable insulation sleeve. - 1 Set

Page 98: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

Outgoing

17 Set of (1 No. 40 Amps 4P MCB before energy meter, three phase Electronic energy meterwith required number of CT's and 1 No. 40 Amps 4P MCB after energy meter complete with allaccessories including wiring etc. as required as per single line diagram.

Spare40 Amp 4P MCB - 2 No.63 Amp 4P MCB - 1 No.Notes:-All MCCB's shall be of 35 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

MDB-2 & MDB-1 as described as above. Set 2.00

27 MDB-5 (Tower 31A)Incoming

1 No. 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 400/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

500 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing3 No. of 125 Amps TPN MCCB complete with all accessories including wiring etc. as required asper single line diagram.2 No. of 160 Amps TPN MCCB complete with all accessories including wiring etc. as required asper single line diagram.Spare125 Amps TPN MCCB - 1 No.160 Amps TPN MCCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

MDB-5 as described above Set. 1.00

28 MDB-6 (Tower 31A)Incoming

1 No. 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 400/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

500 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing5 No. of 125 Amps TPN MCCB complete with all accessories including wiring etc. as required asper single line diagram.Spare125 Amps TPN MCCB - 1 No.

Page 99: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

100 Amps TPN MCCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

MDB-6 as described above Set. 1.00

29 SDB-5.3, 5.4, 6.5, 6.4, 6.3, 6.2, 6.1 (Tower 31A)Incoming

1 No. 125 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 125/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing10 No. of 32 Amps DP MCB complete with all accessories including wiring etc. as required as persingle line diagram.Spare32Amps DP MCB - 2 No.40 Amps 4P MCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

SDB-5.3, 5.4, 6.5, 6.4, 6.3, 6.2, 6.1 as described above Set. 7.00

30 SDB-5.1 (Tower 31A)Incoming

1 No. 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 160/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing10 No. of 32 Amps DP MCB complete with all accessories including wiring etc. as required as persingle line diagram.2 No. of 40 Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.1 No. of 63 Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.Spare32Amps DP MCB - 1 No.63Amps 4P MCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

Page 100: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

SDB-5.1 as described above Set. 1.00

31 SDB-5.2 (Tower 31A)Incoming1 No. 125 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:VAF digital electronic meter with inbuilt selector switch and 120/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing9 No. of 32 Amps DP MCB complete with all accessories including wiring etc. as required as persingle line diagram.Spare32Amps DP MCB - 2 No.63Amps 4P MCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

SDB-5.2 as described above Set. 1.00

32 MDB-8 (Guest House)Incoming

1 No. 250 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 250/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

300 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing5 No. of 32 Amps TPN MCB complete with all accessories including wiring etc. as required as persingle line diagram.5 No. of 40 Amps TPN MCB complete with all accessories including wiring etc. as required as persingle line diagram.Spare32Amps TPN MCB - 2 No.40 Amps TPN MCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

MDB-8 as described above Set. 1.00

Page 101: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

33 Emergency Panel & Common Area 7.3 & 7.4 (Tower 29 & 27A)Incoming1 No. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessor basedrelease for short circuit, over current, earth fault protection with adjustable setting, ON/ OFF/Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 60/ 5 Amps 15 VA, CL 1 CTs . -1 Set

Phase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

150 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing3 No. of 32 Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.1 No. of 32 Amps DP MCB complete with all accessories including wiring etc. as required as persingle line diagram.1 No. of 40 Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.Spare40 Amps 4P MCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

Emergency & Common Area Panel 7.3 & 7.4 as described above Set. 2.00

34 MDB-7 (Animal House)Incoming1 No. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:VAF digital electronic meter with inbuilt selector switch and 100/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing1 No. of 63 Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.1 No. of 40 Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.8 No. of 40 Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.Spare40 Amps 4P MCB - 1 No.32 Amps 4P MCB - 1 No.Notes: -All MCCB's shall be of 25 kA (Ics) breaking capacity.All MCB's shall be of 10 kA breaking capacity.

MDB-7 as described above Set. 1.00

Page 102: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

35 Director's bunglow 4 way TPN DB (BPU & NABI)Incoming1 No. 63 Amps TPN MCB as per specifications & SLD:Dual Energy (digital) meter with 60/ 5 Amps 15 VA, CL 1 CTs . -1 SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars

100 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing2 No. of 40Amps 4P MCB complete with all accessories including wiring etc. as required as persingle line diagram.Spare40 Amps TP MCB - 2 No.Notes: -All MCB's shall be of 10 kA breaking capacity.

Director's bunglow 4 way TPN DB (BPU & NABI) as described above Set. 2.00

36.00 Terminal BoxIncoming

Supplying, installation, testing and commissioning of 250 mm x 400 mm x 150 mm (WxLxD)consolidation ms box, power coated with perforated door and suitable knockouts for conduitentry at top & with lockable cover plate.

No. 38.00

Isolators for following Ratings for UPS Incoming

37.00 200 A TPN MCCB No. 3.00

38.00 125 A TPN MCCB No. 3.00

39.00 63 A TPN MCCB No. 4.00

LIGHTING FIXTURES AND FANSSITC of the following lighting fixtures with all fixing accessories etc. as required.

40

Recessed Type channel office 1x28 WT5 with AL Specular Louvre Batwing. Make: Philips TBX321 1x28 TL5 EBP M or equivalent as per approved Make. (Labs,Office and Common AreaaAmenties Alternate-1)

each 35.00

41Recessed mounted 2 x 18 W with fully frosted Glass. Make: Wipro WCP 27 27218 SGW orequivalent as per approved Make. each 30.00

42

Recessed Type channel office 1x28 W T5 with Opal diffuser. Make: Philips TBX 311 1 x28 W TL5EBP O-SAT or equivalent as per approved Make. (Labs,Office and Common Areaa AmentiesAlternate-2)

each 93.00

43

Surface mounted Fluorescent light fixture 1x28 W/2x28 W with T5 Tube Light.Make:CromptonType T5JB13228EB9 or equivalent as per approved Make(Parking,Utility, Store &Electrical Substation)

each 140.00

44

Surface/ Wall mounted Fluorescent light fixture 1x28 W/1x14W with T5 Tube Light withDiffuser.Make : Crompton,Type T5LK1128 or equivalent as per approved Make(Toilet Blocks &Pantry)

each 281.00

45Recessed mounted 2 x 36 W compact flourescent tube light with diffuser. Philips FBS 440 2xPL-L36W SP EBT or equivalent as per approved Make(Conference & Meeting) each 81.00

46

Recessed mounted 2xPL-L36W EBT D6 DF-WH light fixture with Direct Indirect and Low Glare 3DOLC Optics.Philips FBS 580 2xPL-L36W SP EBT/ CG CRDIA236EB or equivalent as per approvedMake(Office & Labs).

each 965.00

Page 103: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

47Reccesed mounted 1x28W/ 1x54W T5 Wall Washer Light. Make: Philips Type TBS 207 1xTLD-36W HFB A or equivalent as per approved Make(Conference, Meeting Area & Cabins). each 145.00

48 Surface mounted 2x18 W T5 CFL with diffuser. Make: Thorn Type: ORBITILITE S/ CG DCR218EBorequivalent as per approved Make (Corridor & Passage).

each 502.00

49 Bulk Head lighting fixture Philips make FXC-101 1xPL-S/ 2P 9W AC GR or equivalent as perapproved Make complete with PL-9 lamp.

each 22.00

50 Occupancy Sensors complete with all accessories as required. Make: Philips Lmetre 1071 orequivalent as per approved Make (Staircase Lobby/ Foyer)

each 10.00

51 Aviation obstruction light cluster of LED's with step down transformer Bajaj make or equivalentas per approved Make complete as required.

each 5.00

52Surface mounted linear fluorescent light fixture 1x28 W T5 tube light with diffuser. Make: PhilipsFWG 300 WALLLIGHT or equivalent as per approved Make(Toilets, Bed Rooms, Living, Dining,Store, Kitchen, Guest Room)

No. 177.00

53 Wall mounted light fixture 75 W with Halogen lamp. Make:Philips Ledino wall light or equivalentas per approved Make (Bed Rooms)

No. 90.00

54Wall mounted Fluorescent light fixture 2x36 W with fluorescent lamp. Make : Thorn Avanti2x55W TC LHF Direct/Indirect head 96004638 or equivalent as per approved Make(Bedroom/Living).

No. 71.00

55Surface/ Wall mounted Fluorescent light fixture 1x28 W with T5 Tube Light.Make : Philips Adreno28W or equivalent as per approved Make( Utility Store, Servant's room, attendant's room) No. 76.00

56Surface mounted Fluorescent light fixture 2x9 W with compact fluorescent lamp. Thorn NovelloCNVS 209(LPF) or equilvalent as per approved Make.(Passage betwwen dining and servant'sroom)

No. 118.00

57Surface mounted Flourescent downlighter, with acrylic diffuser light fixture, with 2 x 18 W withcompact flourescent lamp.Make : Artlite RL 2815 2x18W/ CG DWLDA07IH or equivalent as perapproved Make (Passage, Baclony)

No. 337.00

58Surface mounted Compact fluroscent downlighter with fully frosted glass 2 x 18 W compactflourescent lamp.Make : Artlite RL-2802 / CG CBH13 or equivalent (Main Corridor, living room,balcony, stair landing)

No. 518.00

59Decorative Suspended lighting fixturep down light fixture with 1 x 42 W compact flourescentlamp.Make: Glacier II 42W CFL large Version with Priamatic Reflector or equivalent as perapproved Make (Reception, Living & Private Dining).

No. 2.00

60Wall mounted upligther mounted at double height fixture with 1 x 150 W/ 70 W CDMTlamp.Make:Philips DCP 731 or equivalent as per approved Make(Enatrance poarch, lobby,waiting).

No. 16.00

61Wall/Surface mounted linear fluorescent light fixture 1x14 W T5 tube light with diffuser. Make:Philips Coral WRF81128 SG or equivalent as per approved Make (Servant's toilet, Toilets, BedRooms, Living, Dining, Store, Kitchen, Guest Room).

No. 44.00

62Wall mounted up and downlight light fixture 1x75 W light. Make: Philips DCP 721 or equivalentas per approved Make (Stair landing).

No. 158.00

63Surface / wall mounted linear fluorescent light fixture 1x14 W T5 tube light with diffuser. Make:Philips Adreno 14 W or equivalent as per approved Make (Toilets, Wash basin)

No. 96.00

64Wall mounted CFL light fixture 1x13 W T5 tube light with diffuser. Make: Reiz 156450 SilverFinish /CG CBH13 or equivalent as per approved Make(Bedrooms)

No. 141.00

65Surface / wall mounted linear fluorescent light fixture 1x28 W T5 box tube light with diffuser.Make: Philips TMS122M 1XTLS 28 W EBE or equivalent as per approved Make (Utylity, store,servant's room)

No. 28.00

Page 104: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

66Decorative Suspended lighting fixture up down light fixture with 1 x 36 W compact flourescentlamp. Make: Philips Suspension light QPG304 24W or equivalent (Drawing Room and Dining).

No. 64.00

67Wall mounted water tight fixture with diffuser with 1 x42W CFL lamp. Make: Philips DCP711 2xPL-C/2P-18W or equivalent as per approved Make (Terrace and External)

No. 92.00

68Foot Light recessed mounting, water tight, with 1x18W lamp. Make: Artlite RL-4120 orequivalent as per approved Make(External)

No. 29.00

69 Occupancy Sensors complete with all accessories as required. (Staircase Lobby/ Foyer) No. 104.00

70Aviation obstruction light cluster of LED's with step down transformer Bajaj make or equivalentas per approved Makecomplete as required

No. 9.00

71SITC of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sqmm FRLS PVC insulated copper conductor , single core cable ete. As required.

a 1400 mm Sweep Ceiling Fan No. 156.00

b 1200 mm Sweep Ceiling Fan No. 149.00

c 900 mm Sweep Ceiling Fan No. 14.00

d 300 mm dia Domestic Exhaust Fan No. 30.00

e 250 mm dia Domestic Exhaust Fan No. 27.00

f 200 mm dia Domestic Exhaust Fan No. 118.00

g 225 mm dia Light Duty Trans-air bird screen for protection against birds and foreign matter. No. 31.00

h 5 Star rated ES-50 Premium White/Brown/Ivory energy saving Fan each 5.00

ACCESSORIES FOR TELEPHONE/TV NETWORK SYSTEM

72Supply, fixing, cable temetreination, testing and commissioning of Tag Blocks of Krone make orequivalent and boxes with lockable doors made out of 1.2 mm CRCA sheet with epoxy polystercoating as required.

a 10 pair tag box No. 39.00

b 20 pair tag box No. 2.00

c 30 pair tag box No. 1.00

d 40 pair tag box No. 1.00

e 50 pair tag box No. 3.00

f 60 pair tag box No. 1.00

g 100 pair tag box each 10.00

h 300 pair tag box each 3.00

73Supply, installation, testing and commissioning of following Telephone cable on existing cabletrays. The cable shall be as per the specifications laid down in the tender.

a 5 pair 0.61mm cable metre 1,026.00

b 10 pair 0.61mm cable metre 160.00

Page 105: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

c 20 pair 0.61mm cable metre 149.00

d 50 pair 0.61mm cable metre 110.00

UPS74 30 kVA UPS 3 phase (415 V + 15%) Volts input & 3 phase output (415 V + 1%), 50 Hz, Input

hametreonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 10 minbattery backup for UPS along with battery cabinet complete in all respect including supportingsteel structure for UPS and Battery as required.

each 2.00

75 Dismentalling, shifting & re-installation as per drawing of existing 40 kVA UPS 3 phase (415 V)Volts input & 3 phase output (415 V), 50 Hz, at 100% load and battery backup (existing) forUPS along with battery cabinet complete in all respect supporting steel structure etc. for UPSand Battery complete as required.

each 2.00

76 Dismentalling, shifting & re-installation as per drawing of existing 60 kVA UPS 3 phase (415 V)Volts input & 3 phase output (415 V), 50 Hz, at 100% load and battery backup (existing) forUPS along with battery cabinet complete in all respect supporting steel structure etc. for UPSand Battery complete as required.

each 2.00

77 120 kVA UPS 3 phase (415 V + 15%) Volts input & 3 phase output (415 V + 1%), 50 Hz, Inputhametreonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 10 minbattery backup for UPS along with battery cabinet complete in all respect including supportingsteel structure for UPS and Battery as required.

each 3.00

INVERTER78 Supply, installation, testing and commissioning of 1 phase input and 1 phase output inverters of

1.5 kVA rating. Sine wave inverter, including batteries etc as required.No. 3

SPLIT AIR CONDITIONING WORK76 Supply, installing, testing and commissioning of wall mounted AIR COOLED SPLIT AIR

CONDITIONING UNITS as described in specifications. The unit shall be complete with Hi walltype Indoor unit and external condensing unit, complete in all respects, inclusive of copperrefrigerant piping, GI condensate drain piping, valves and insulation. Quoted price shall includecost of thermostat, wiring, control cooling thermostat, wiring, control wiring, and earthing Theunit capacities shall be after taking deration into account due to copper piping lengths:

The quoted price shall include the GI frame structure to mount the outdoor unit or to suit thesite condition.

a 2 TR split air conditioning units as described above No. 4.00

b 1.5 TR split air conditioning units as described above No. 29.00

c 1 TR split air conditioning units as described above No. 9.00

77

Supplying, installing, testing and commissioning of direct driven PROPELLER FANS for exhaustair as shown in drawings. Each fan shall be complete with permanent split capacitor or shadedpole motor, mounting plate, accessories like wire guard, bird screen and fixed louvers forweather protection as required. Fan selection arrangement and Electrical characteristics shall beas follows :

a 150 mm dia 900 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply. No. 43.00 MECHANICAL VENTILATION WORKS

Page 106: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

78.0

Supply, installation, testing & commissioning of AXIAL FLOW FAN suitable for installing in anyposition in Horizontal or vertical and complete with totally enclosed fan cooled motor belt drive,multi sheaved pulley mounted on motor and fan shaft, belt guard, motor mount and vibrationisolators. The fan shall be selected for low noise level and low RPM (less than 1000 RPM) Fanmotor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply with highefficiency,EFF-1 type. The fan shall be equipped with mounting bracket & outlet core required atdischarge. Minimum 15 mm (WC) external static pressure after fan outlet. Total static pressureshall be checked by Vendor.

Fan Tag : Space Fed : CFM : Motor HPLift Well Pressurization

a TAF-1 : Tower - 27 A-Apt Type III & IV : 26000 : 7.5 Each 1.00

b TAF-2 : Tower - 29 A-Apt Type IV & V : 26000 : 7.5 Each 1.00

c TAF-3 : Tower - 31 A : 26000 : 7.5 Each 1.00

Note : Lift well Pressurization fan shall be for outdoor application & provided with cannopy ofmaterial similar to casing.AIR DISTRIBUTION

79.0Supply, installation and testing of Factory fabricated GI sheet metal ducts as per SMACNA inaccordance with the approved shop drawings and as required by the specifications.

a 24 gauge galvanised sheet steel Sqm 150.00

80.0Supply, fabrication, installation and testing the flexible connections constructed of fireresistant double resin sleeve as per the approved shop drawings.

Sqm 7.00

81.0Supply, installation, testing and balancing of powder coated Extruded Aluminium supply airGrilles with volume control dampers in accordance with the approved shop drawings andspecifications.

Sqm 4.00

Supply, installation, testing and balancing of powder coated extruded aluminium Air Grilleswithout volume control dampers.

Sqm

82.0

Supply, installation, testing and commissioning of motorized volume control ON /OFF typedampers of extruded aluminium construction in fresh air/return air/exhaust air steams. Thedamper actuator must accept signal from BMS system. Maximum leakage rate from dampersshall be in accordance with AMCA standard 500 . Quoted price shall also be included controlwiring of damper.

a Motarised Damper Sqm 4.00

b Control Panel & Wiring(with actuators) Each 3.00

83 CONTROL PANELS FOR FANS ( TUBE AXIAL FLOW FANS)Design, manufacture, supply, installation, testing and commissioning of the following cubicletype, dead front, sheet steel, wall mounted control panels, including anchoring into the wall,wiring terminating into MPCB and copper earthing, in each panel shall be provided by theelectrical contractor.The panel shall include the following components & accessories .

a. MCB / MCCB with built-in overload relay and single phase preventor as per the ratings givenbelow, suitable for motor duty and able to withstand fault level of 20 KA.

b. Terminal block for power distribution as required.c. Contactor, over load relay with built in single phasing protection.d. Phase indicating lights and indicating light for `ON’ status.e. 96 mm x 96 mm voltmeter and ammeter.f. Time delay relay for delayed automatic restart of motor (0-180 sec).g. The Control panel shall be out door type and shall have potential free contacts for fire alarmintegration.

Page 107: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

h. For on/off/remote and local operation, 3 pole single throw switch shall be provided in eachpanel to facilitate override of the automatic operation.The number of control panels shall be as follows.

a MPCB with DOL starters suitable for 1-7.5 HP motors Each 3.00

CABLES, MAINS AND SUB MAINS

84

Supplying of following 1100 volt grade PVC insulated sheathed copper conductor un-armouredcable as per specification in existing trenches, cable trays ducts over bed of sand, clampedincludes anchor fastners to wall with suitable clamps, saddles fixing bolts including connectingtesting and commissioning.

a 4 Core 6 Sq.mm metre 30.00

END TERMINATION OF CABLES

85Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.

a 4 Core 6 Sq.mm. (Copper Unarmoured Cable) No. 6.00

TOTAL OF SUB HEAD (A)

SUB HEAD (B):ELECTRICAL HIGH END -UTILITY-1SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SUB-STATION EQUIPMENT

86 Main 11 kV HT Panel Design, fabrication, assembling, wiring, supply, testing at works, packaging, forwarding to siteand supervising the testing & commissioning of 11 kV, 50 Hz 3 phase, 630 Amps indoor drawouttype switchboard with 18.4 kA VCB circuit breaker as per specifications with following:

Incomer one number consisting of MS sheet enclosed cubicle type panel with main bus rated for 630 A and droppers rated for 630A.630 Amps electrically operated trip free type vacuum circuit breaker at 50 deg.C ambient.

Breaker control switch.24 V DC tripping coil.24 V DC closing coil.Spring charging motor.Set of ON/OFF/TRIP indicating lamps.Set of Phase indicating lamps.Clear lamp for trip circuit health supply.Digital ammeter with inbuilt selector switch.Digital electronic Voltmeter with inbuilt selector switch.Digital Frequency Meter with inbuilt selector switch.Aux. relays for Anti Pumping & indication.Trip circuit supervision and lock out relay.2 over current & Earth Fault IDMT relay with high set element range 500 – 2000% 3 No. Cast resin CTs of dual ratio 100-200 / 5 Amps CL:1, 5P10, 15 VA.3 No. Cast resin drawout type PTs 11 kV / √3 / 110 √3, class 1, 100 VA.Suitable space for termination of 1 No. 11 kV, 3 C x 300 sq.mm XLPE cable as incoming.

Outgoing two number consisting of:MS sheet enclosed cubicle type panel with main bus rated for 630 A and droppers rated for 630A630 Amps electrically operated trip free type vacuum circuit breaker at 50 deg.C ambient.

Breaker control switch.24 V DC tripping coil.

Page 108: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

24 V DC closing coil.Spring charging motorSet of ON/OFF/TRIP indicating lamps.Set of Phase indicating lamps.Clear lamp for trip circuit health supply.Digital ammeter with selector switch.Aux. relays for Anti Pumping & indication.Trip circuit supervision and lock out relay.2 over current IDMT relay with high set element range 500 – 2000% 3 No. Cast resin CTs of dual ratio 50-100 / 5 Amps CL:1, 5P10, 15 VA.3 No. Cast resin CTs of dual ratio 50-100 / 5 Amps, 5P10, 15 VA.12 window alarm annunciator with windows and buzzer, ACK, rest, test push button for eachtransformer faults and electrical faults in each outgoing panel.Suitable space for termination of 1 No. 11 kV, 3 C x 300 sq.mm XLPE cable as outgoing.

Main HT Panel described as above Set 1.00

87 11 kV HT Panel Design, fabrication, assembling, wiring, supply, testing at works, packaging, forwarding to siteand supervising the testing & commissioning of 11 kV, 50 Hz 3 phase, 630 Amps indoor drawouttype switchboard with 18.4 kA VCB circuit breaker as per specifications with following:

Incomer one number consisting of MS sheet enclosed cubicle type panel with main bus rated for 630 A and droppers rated for 630A.630 Amps electrically operated trip free type vacuum circuit breaker at 50 deg.C ambient.

Breaker control switch.24 V DC tripping coil.24 V DC closing coil.Spring charging motor.Set of ON/OFF/TRIP indicating lamps.Set of Phase indicating lamps.Clear lamp for trip circuit health supply.Digital ammeter with inbuilt selector switch.Digital electronic Voltmeter with inbuilt selector switch.Digital Frequency Meter with inbuilt selector switch.Aux. relays for Anti Pumping & indication.Trip circuit supervision and lock out relay.2 over current & Earth Fault IDMT relay with instantaneous high set element range 500 – 2000%

3 No. Cast resin CTs of dual ratio 100-200 / 5 Amps CL:1, 5P10, 15 VA.3 No. Cast resin drawout type PTs 11 kV / √3 / 110 √3, class 1, 100 VA.Suitable space for termination of 1 No. 11 kV, 3 C x 300 sq.mm XLPE cable as incoming.

Outgoing two number consisting of:MS sheet enclosed cubicle type panel with main bus rated for 630 A and droppers rated for 630A630 Amps electrically operated trip free type vacuum circuit breaker at 50 deg.C ambient.

Breaker control switch.24 V DC tripping coil.24 V DC closing coil.Spring charging motorSet of ON/OFF/TRIP indicating lamps.Set of Phase indicating lamps.Clear lamp for trip circuit health supply.Digital ammeter with selector switch.

Page 109: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

Aux. relays for Anti Pumping & indication.Trip circuit supervision and lock out relay.Tripping relay for each type of transformer fault.Restricted Earth Fault ( CAG - 14 ) relay with CT's.C8772 over current IDMT relay with instantaneous high set element range 50 – 2000% 3 No. Cast resin CTs of dual ratio 50-100 / 5 Amps CL:1, 5P10, 15 VA.3 No. Cast resin CTs of dual ratio 50-100 / 5 Amps, 5P10, 15 VA.12 window alarm annunciator with windows and buzzer, ACK, rest, test push button for eachtransformer faults and electrical faults in each outgoing panel.Suitable space for termination of 1 No. 11 kV, 3 C x 300 sq.mm XLPE cable as outgoing.

Main HT Panel described as above Set 1.00

88

Supply, installation, testing and commissioning of 1600 kVA 3 phase, 11/ 0.433 kV indoor drytype Transformer copper wound with Dyn 11 connection and neutral brought out for earthing.The transformer shall be provided with +5 and -10 % On load tap changer on HT side. HT sidecable termination box shall be suitable for 11 KV, 3 C x 300 mm 2 XLPE cable and LT sideterminal box shall be suitable for termination of 2500 Amps TPN Al. Bus Duct. The transformershall be supplied with all standard fitting viz thermistors for Alarm and Trip, winding temperaturerelay unit with Alarm and trip, lifting lugs, earthing studs and marshlling box, etc. complete in allrespect as required as per specification.

Set 2.00

HT & LT CABLES

89Supply, Laying in Open Duct/ Trench and Testing of following sizes of XLPE insulated PVCsheathed aluminium conductor armoured power cable of 11 kV grade (11 kV earthed system).

a 3 Core 300 Sq.mm. metre 800.00

90Supplying of following 1100 volt grade XLPE insulated PVC inner sheathed and HR PVC outersheathed aluminium conductor armoured cables as required as per specifications.

a 3.5 core 400 sq.mm metre 530.00

b 3.5 core 300 sq.mm metre 1,144.00

c 3.5 core 240 sq.mm metre 200.00

d 3.5 core 150 sq.mm metre 440.00

e 3.5 core 70 sq.mm metre 110.00

f 4 core 25 sq. mm metre 715.00

91

Supplying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cableas per specification in existing trenches, cable trays ducts over bed of sand, clamped includesanchor fastners to wall with suitable clamps, saddles fixing bolts including connecting testing andcommissioning.

a 3 core 4 sq. mm metre 250.00

b 3 core 6 sq. mm metre 250.00

c 4 core 2.5 sq.mm control cable metre 100.00

d 7 core 2.5 sq.mm control cable metre 100.00

e 12 core 2.5 sq.mm control cable metre 100.00

Page 110: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

92

Cable end termination of the following PVC insulated sheathed PVC/XLPE aluminium / copperconductor armoured cables of 1100 volt grade including supplying and fixing of crimpingaluminium lugs, double compression glands with earthing facility at both ends of cables etc.complete as required.

a 3 core 4 sq. mm metre 6.00

b 3 core 6 sq. mm metre 6.00

c 4 core 2.5 sq.mm control cable each 4.00

d 7 core 2.5 sq.mm control cable each 4.00

e 12 core 2.5 sq.mm control cable each 4.00

93 MAIN LT PANEL CUM CHANGEOVER PANEL

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of MainLT Panel cum DG Sysnchronizing panel fabricated out of 14 gauge CRCA sheet steel in cubiclecompartmentised free standing floor mounted, dust and vermin proof with reinforcement ofsuitable size angle iron, channel `T’ section and/ or flats wherever necessary. 3 mm thick cablegland plates shall be provided on top as well as at the bottom of the panel as per siterequirement.Panel shall be treated with all anticorrosive process before powder coating as perspecification and final approved shade. 2 No. earthing terminals shall be provided for the panel.Panel shall be suitable for 433 V, 3 phase, 4 wire, 50 HZ supply system, with extensible busbarson both sides, making suitable electrical/ mechanical interlocking arrangement betweenincomers & buscoupler breakers, interconnection, duly powder coated painting etc. includingsupply & installation of following switchgears, metering instruments and accessories as perspecifications. (All breakers breaking capacity shall be 50 kA. ICU = ICS). Lifting hooks shall alsobe provided in the panel).

Approval shall be taken for the panel in the fometre of shop drawings before fabrication.Galvanised hardwares with zinc passivation shall be used in fabrication of panel.

Section - IINCOMER - 1 (1600 kVA Transformer)Incoming for 1 each 1600 kVA Transformer comprises the following and as per single linediagram.2500 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting as per specification and with followingaccessories :Digital energy meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-I, with 3Nos. 2500/5 amps 15VA CTs.Phase indicating light shall be protected by 2 amps MCB’s. - 3 SetThree Phase Under voltage relay MV12 or equivalnt (27) - 1 SetThree Phase Over voltage relay MV 12 or equivalent (59) - 1 SetBreaker ON/ OFF/ TRIP indicating lights with control MCB’s. - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.Three Phase Voltage sensor relay shall be protected by 2 amps TP MCB’s. - 1 SetTransient voltage surge supressor with suitable contactor shall be protected by 2 amps TPMCB’s. - 1 Set1 each 2500/1250/ 5, 15 VA dual ratio CT’s shall be provided for APFCR on transformer incomer.

INCOMER - 2 (DG Syn Panel)

Page 111: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

2500 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit , for short circuit, over current and earth fault protection withadjustable setting as per specification and with following accessories :

Electronic Load manager meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracyclass-I, with 3 Nos. 2500/5 amps 15VA CTs.VAF digital electronic meter with inbuilt selector switch and 2500/5 Amps suitable VA, CL 1 CTs .- 1 SetPhase indicating light shall be protected by 2 Amps MCB - 3 SetBreaker ON / OFF / TRIP indicating lights with control MCB’s - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.BUSBARS3200 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy as perspecification.OUTGOING1000 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting - 2 each 1600 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting including dual electronic energy meter (EM6438 or equivalent with RS 485 port) with 1600/5 Amps suitable VA, CL 1 CT - 1 each

1250 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting including dual electronic energy meter (EM6438 or equivalent with RS 485 port) with 1250/5 Amps suitable VA, CL 1 CT - 1 each

250 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 250/5 Amps suitable VA, CL 1 CT - 1 each

100 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 100/5 Amps suitable VA, CL 1 CT - 3 each

63 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor based releaseunit with adjustable setting including dual electronic energy meter (EM 6438 or equivalent withRS 485 port) with 60/5 Amps suitable VA, CL 1 CT - 1 each

Bus Coupler (1 ACB) shall be equipped with the following:2500A, 4 poles electrically draw out type motor operated air circuit breaker with microprocessorrelease unit (Type 2A of MG make or equivalent).

24V D C shunt coil.415 under voltage release.1 each 230 V A.C closing coil.Breaker control switch.On/ Off/ Trip indicating lamps.Spring charged indication.Section - IIINCOMER - 1 (1600 kVA Transformer)Incoming for 1 each 1600 kVA Transformer comprises the following and as per single linediagram.

Page 112: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

2500 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting as per specification and with followingaccessories :

Digital energy meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-I, with 3Nos. 2500/5 amps 15VA CTs.Phase indicating light shall be protected by 2 amps MCB’s. - 3 SetThree Phase Under voltage relay MV12 or equivalnt (27) - 1 SetThree Phase Over voltage relay MV 12 or equivalent (59) - 1 SetBreaker ON/ OFF/ TRIP indicating lights with control MCB’s. - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.Three Phase Voltage sensor relay shall be protected by 2 amps TP MCB’s. - 1 SetTransient voltage surge supressor with suitable contactor shall be protected by 2 amps TPMCB’s. - 1 Set

1 each 2500/1250/ 5, 15 VA dual ratio CT’s shall be provided for APFCR on transformer incomer.

INCOMER - 2 (DG Syn Panel)2500 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit , for short circuit, over current and earth fault protection withadjustable setting as per specification and with following accessories :

Electronic Load manager meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracyclass-I, with 3 Nos. 2500/5 amps 15VA CTs.

VAF digital electronic meter with inbuilt selector switch and 2500/5 Amps suitable VA, CL 1 CTs .- 1 Set

Phase indicating light shall be protected by 2 Amps MCB - 3 SetBreaker ON / OFF / TRIP indicating lights with control MCB’s - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.BUSBARS:3200 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy as perspecification.

OUTGOING:1000 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting - 1 each

1000 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting including dual electronic energy meter (EM6438 or equivalent with RS 485 port) with 1000/5 Amps suitable VA, CL 1 CT - 2 each

1250 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting including dual electronic energy meter (EM6438 or equivalent with RS 485 port) with 1250/5 Amps suitable VA, CL 1 CT - 1 each

Page 113: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

800 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting including dual electronic energy meter (EM6438 or equivalent with RS 485 port) with 800/5 Amps suitable VA, CL 1 CT - 1 each

250 amps TPN Electrically Operated Manually draw out type Air Circuit Breaker (Icu = Ics) withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting including dual electronic energy meter (EM6438 or equivalent with RS 485 port) with 800/5 Amps suitable VA, CL 1 CT - 4 each

63 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor based releaseunit with adjustable setting including dual electronic energy meter (EM 6438 or equivalent withRS 485 port) with 60/5 Amps suitable VA, CL 1 CT - 1 each

Main LT Panel cum Changeover Panel as described above. each 1.00

94 FEEDER PILLAR (Outdoor type)

Incoming1 each 125 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microproccessorbased release for short circuit, over current, earth fault protection with adjustable setting, ON/OFF/ Trip indication lamp including control MCB's with fuse and following accessories as perspecifications & SLD:

VAF digital electronic meter with inbuilt selector switch and 125/ 5 Amps 15 VA, CL 1 CTs . -1SetPhase indicating light shall be protected by 2 Amps SP MCB's - 3 SetBus Bars200 Amps TPN Aluminium bars with heat coloured shrinkable insulation sleeve - 1 Set

Outgoing63 Amps TPN MCCB complete with all accessories including wiring etc. as required as per singleline diagram - 2 set63Amps 4P MCB - 2 eachSpare63Amps 4P MCB - 1 each63Amps TPN MCB - 2 eachNotes: -i. All MCCB's shall be of 25 kA (Ics) breaking capacity.ii. All MCB's shall be of 10 kA breaking capacity.Feeder Fillar as described above Set. 1.00

95 400 KVAR CAPACITOR AUTOMATIC CONTROL PANEL

INCOMING1000 amps TPN manually operated fully drawout type air circuit breaker as per specification andwith following accessories:96 x 96 mm sq. 0-500 Volt digital voltmeter with selector switch Phase indicating light shall be protected by 2 Amps SP MCB’s - 3 SetPower factor compensating relay (including power factor meter) in 11 steps for automatic cut offor add on capacitor units to keep the power factor at 0.97 with variation of loads. All associatedauxiliary contactors/ relays/ timer/ auto manual selector switches to be provided - 1 Set.

BUS BARS:1250 amps TPN Aluminium bus bars with coloured heat Shrinkable insulated sleeves. - 1 set

OUTGOING - I:Outgoing feeders consisting of following accessories.

Page 114: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

125 amps TPN MCCB - 5 Set125 amps or capacitor duty 525 volts 50Hz contactors. - 5 Sets“ON” /”OFF” push buttons and indicating lamps. - 5 Sets50 KVAR, 525 volts capacitor unit with detune filters as specified - 5 SetsOUTGOING - II:Outgoing feeders consisting of following accessories.80 amps TPN MCCB - 6 Set80 amps or capacitor duty 525 volts 50Hz contactors. - 6 Sets“ON” /”OFF” push buttons and indicating lamps. - 6 Sets25 KVAR, 525 volts capacitor unit with detune filters as specified - 6 SetsNote:All MCCB’s shall be of 50 KA breaking capacity.Fast response time of ‘ON’ capacitors 40-60 miliseconds. Necessary control and firing card with proper wiring and lugs of the required rating to beprovided.Heavy duty exhaust fans to be provided for cooling Thyristors.LED indication for number of capacitor banks ‘ON’.LED indication of Power Factor lagging or leading.The APFC system shall be provided with following :Protections :a. Over voltage.b. Voltage imbalance.c. Over temperature-system should be in standby mode & automatically restart after abovecondition restored.d. Earth leakage.e. 7% value reactors with iron core.Capacitor automatic control panel (400 kVAr) as described above. each 2.00

BATTERY & BATTERY CHARGER

96

Supply, Installation, Testing and Commissioning of 1 (One) number 24 V Battery Charger & 2(Two) numbers of 12V 200 AH maintenance free sealed lead acid batteries, Battery Chargershall be solid state, full wave fully controlled bridge, input suitable for single phase 230V ACsuppply, conforming to degree of protection IP-42, Sheet steel enclosure 2 mm thick withautomatic voltage regulation, current limiting circuitary, auto cut facility, smooth filter circuitswitches, Ammeter & voltmeter on DC side, phase indicating lamps (LED type) on AC sidecomplete in all respect with float and boost/ buck charging, switchgear, earthing, powder coatedpainting etc as required.

Job 1.00

97 Supplying of Rubber hand gloves suitable for 11 kV. Pair 2.00

98 Supplying and fixing of Shock treatment chart both in Hindi & English. each 4.00

99Supply and fixing Carbon dioxide fire extinguishers of 4.5 kg capacity each as per IS : 2878-1976 and mounting the same on wall by means of suitable hooks. each 4.00

100 Supply and fixing Dry Chemical fire extinguishers 5 kg as per IS : 2171-1976. each 2.00

101 Supply and fixing of 9 ltr mechanical foam type fire extinguisher each 2.00

102Supply and fixing 5No.Fire buckets 9 litre capacity filled with dry sand and fixed MS structure,made out of 40x6mm angle and hange with bracket . each 1.00

103Supply of First aid box containing material as prescribed by St. John Ambulance brigade ORIndian Red Cross complete as required. each 2.00

Page 115: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

104

Supply & fixing of fire retardant/ extinguishing Electrical Insulated synthetic mat of 3.0 mm thick+/- 10% conforming to latest BIS: DOC NO. ET-02 (5440) meeting requirements of IS 3043, IS5216 (part-1, 2&3), IS 8437 and IEC 479, suitable for all voltages up to & including 33 kV ACand having minimum width of 1000 mm +/- 20 mm and including supply of required quantity ofadhensive / compound and fixing the same at site as per site requirement.

metre 10.00

105

Supply & fixing of fire retardant / extinguishing Electrical Insulated synthetic mat of 2.0 mmthick + 10% conforming to latest BIS: DOC NO. ET-02 (5440) meeting requirements of IS 3043,IS 5216 (part-1, 2&3), IS 8437 and IEC 479, suitable for all voltages not exceeding 3.3 kV ACand 220 V DC supply and having minimum width of 1000 mm +/- 20 mm and including supplyof required quantity of adhensive / compound and fixing the same at site as per siterequirement.

metre 25.00

106Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminiumsheet including lamination etc. as required complete including fixing the same on wall. Job 2.00

BUS DUCT (IN SANDWICH CONSTRUCTION)

107

Supply, installation, testing and commissioning of following rating (50 KA for 1 Sec) TPNbusduct in sandwich construction of aluminium bus bars with expansion joints, fire barriersincluding necessary supports and louvers for ventilation, fabricated out of extruded aluminium/GI sheet painted with approved paint shade as per specification including 2 No. of 50 x 6 mmcopper earthing conductor through out the length of the bus duct. (Phase sequence shall bematched).Note: Degree of protection for outdoor bus duct shall be IP 55 as per IS:13947-1993.

a 2500 amps TPN bus ducts from Transformer - 1 toLT Cum DG & Tr. Changeover panel including90 deg bends.

metre 10.00

b 2500 amps TPN bus ducts from Transformer - 2 to LT Cum DG & Tr. Changeover panel including90 deg bends.

metre 16.00

c 2500 Amps TPN tinned copper flexible braided end connection on Transformer. each 2.00

d2500 Amps TPN tinned copper flexible braided end connection on LT Cum DG & Tr ChangeoverPanel. each 2.00

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF EXTERNAL LIGHTINGFIXTURES.

1081 X 28W Solar street Light (Philips BRP 402)Fixture with lamp, accessories including MSGalvanized Tubular Pole 6 meter of Pole icluding panels,battery with all accessories etc asapproved by Architect.

each 18.00

1091 X 43W Solar street Light (Philips BRP 403)Fixture with lamp, accessories including MSGalvanized Tubular Pole 6 meter of Pole icluding panels,battery with all accessories etc asapproved by Architect.

each 15.00

1101 x 102.6 W Street Light fixture (Philips RoadStar GPLS 90W 49WLED 4K LEH2)with lamp,accessories etc as approved by Architect. each 62.00

1111 X 44W Street Light (Philips RoadStar & 40W49LED) Fixture with lamp, accessories etc asapproved by Architect. each 45.00

Poles

112

8.5 meter high aluminium painted MS pole with 300mmx300mmx5mm thick base plate and capwelded at bottom complete as required with painting of approved colour including erection ofG.I. pole (410-SP 20 as per IS:2713/80)with single arm (7.5 meter above and 1.5 meter)in1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominalsize) including excavation & refilling etc as required below ground complete as per requirementwith all accessories.

each 52.00

Page 116: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

113

Supply of 8.5 metre, surface mounting, swaged, galvanized pole, as per IS: 1239 (Part-1) -1979 / IS 3601: 1994, with double arm (Metalcoats Make : Swan) bracket, suitable for mountingpendent (hanging) type street lighting cut-off luminaire. The pole shall consists of five sections,made of circular tubes of diameter 165.1 x 3.5mm thick at the bottom section, diameter 139.7 x3mm thick at the second section, diameter 114.3 x 3mm thick at the third section, diameter88.9 x 2.5mm thick at the fourth section. Bracket shall be made of circular tubes of diameter76.1 x 2.5mm thick with overhang length of 1200mm on each side, luminaire mounting tube isinternally threaded of designation FP-1. Bracket assembly is secured on to the pole top withallen grub screws. The pole is provided with built-in control box including service door with lockand safety chain, control gear tray prewired with heavy duty 3 phase, 15Amp terminal block forloop-in loop-out arrangement, 10A SP MCB including all accessories complete as required. Baseplate of size 300 x 300 x 16 mm (steel of grade Fe - 410 to IS 2062: 1999) having elongatedholes for alignment of the pole, welded at the bottom of the pole, 4Nos of M20 x 700mmfoundation bolts hot dip galvanized is provided. The pole is coated with epoxy zinc rich primerand finished with polyurethane based black colour paint, ensuring total thickness of 80 microns.(Metalcoats Make : MC-8269* - Swan Lighting Pole)

each 10.00

114

4.5 meter high Aluminium Painted MS pole with 300mmx300mmx5mm thick base plate and capwelded at bottom complete as required including erection of G.I. pole with B class MS pipe (3.6meter above and 0.9 meter )in 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 gradedstone aggregate 40mm nominal size) including excavation & refilling etc as required belowground complete as per requirement with all accessories.

each 45.00

115

Providing, installation of 200 x 150 x 125 mm polycarbonate weather proof (IP-55) junction boxand SP MCB’s and terminal block. Supplying and laying cable through GI pipe upto junction boxincluding excavation and back filling, wiring with 2 x 2.5 sq.mm PVC insulated 1100 volts gradecopper conductor wires from junction box to lighting fixture complete.

each 107.00

116

Supplying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cableas per specification in existing trenches, cable trays ducts over bed of sand, clamped includesanchor fastners to wall with suitable clamps, saddles fixing bolts including connecting testing andcommissioning.

a 3 C x 2.5 Sq. mm meter 1,125.00

b 3 C x 4 Sq. mm meter 1,800.00

c 3 C x 6 sq.mm meter 1,200.00

117

Making end termination of following size PVC insulated copper conductor 1100 V grade armoredcable including cost of crimping lugs, insulation tapes, double compression glands etc. complete.

3C x 2.5 Sq. mm. each 80.00

3C x 4 Sq. mm. each 100.00

3C x 6 Sq.mm each 30.00

EARTHING INSTALLATION (SUB STATION)

118Supply, Testing & Commissioning, fixing of following bare GI tapes/ wires including all necessaryfixing accessories and effecting connections as per specifications.

a 50 x 5 mm thick GI. tape. metre 275.00

b 50 x 5 mm thick Cu. tape. metre 585.00

SOLAR SYSTEM EQUIPMENT

Page 117: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

119

Supplying installation,testing and commissioning of 15 kWP Solar Photovoltaic system includingPV Modules, module mounting aluminium super structure supported on MS support, stringPCUs,DC DBs arry junction box,main junction boxs, AC DBs with associated copper power cableand control cabling from SPV panel upto ACDB including all accessories as per specificationcomplete in all respect as per site requirement.

Set 1.00

TOTAL OF SUB HEAD (B)

SUB HEAD (C) ELECTRICAL HIGH END-UTILITY-2

120 11 kV HT Panel Design, fabrication, assembling, wiring, supply, testing at works, packaging, forwarding to siteand supervising the testing & commissioning of 11 kV, 50 Hz 3 phase, 630 Amps indoor drawouttype switchboard with 18.4 kA VCB circuit breaker as per specifications with following:

Incomer two number consisting of MS sheet enclosed cubicle type panel with main bus rated for 630 A and droppers rated for 630A.630 Amps electrically operated trip free type vacuum circuit breaker at 50 deg.C ambient.

Breaker control switch.24 V DC tripping coil.24 V DC closing coil.Spring charging motor.Set of ON/OFF/TRIP indicating lamps.Set of Phase indicating lamps.Clear lamp for trip circuit health supply.Digital ammeter with inbuilt selector switch.Digital electronic Voltmeter with inbuilt selector switch.Digital Frequency Meter with inbuilt selector switch.Aux. relays for Anti Pumping & indication.Trip circuit supervision and lock out relay.2 over current & Earth Fault IDMT relay with high set element range 500 – 2000% 3 No. Cast resin CTs of dual ratio 50-100 / 5 Amps CL:1, 5P10, 15 VA.3 No. Cast resin drawout type PTs 11 kV / √3 / 110 √3, class 1, 100 VA.Suitable space for termination of 1 No. 11 kV, 3 C x 300 sq.mm XLPE cable as incoming.

Outgoing two number consisting of:MS sheet enclosed cubicle type panel with main bus rated for 630 A and droppers rated for 630A630 Amps electrically operated trip free type vacuum circuit breaker at 50 deg.C ambient.

Breaker control switch.24 V DC tripping coil.24 V DC closing coil.Spring charging motorSet of ON/OFF/TRIP indicating lamps.Set of Phase indicating lamps.Clear lamp for trip circuit health supply.Digital ammeter with selector switch.Aux. relays for Anti Pumping & indication.Trip circuit supervision and lock out relay.Tripping relay for each type of transformer fault.Restricted Earth Fault ( CAG - 14 ) relay with CT's.2 over current IDMT relay with instantaneous high set element range 50 – 2000% 3 No. Cast resin CTs of dual ratio 20-40 / 5 Amps CL:1, 5P10, 15 VA.

Page 118: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

12 window alarm annunciator with windows and buzzer, ACK, rest, test push button for eachtransformer faults and electrical faults in each outgoing panel.Suitable space for termination of 1 No. 11 kV, 3 C x 300 sq.mm XLPE cable as outgoing.

Main HT Panel described as above Set 1.00

121

Supply, installation, testing and commissioning of 630 kVA 3 phase, 11/ 0.433 kV indoor drytype Transformer copper wound with Dyn 11 connection and neutral brought out for earthing.The transformer shall be provided with +5 and -10 % On load tap changer on HT side. HT sidecable termination box shall be suitable for 11 KV, 3 C x 300 sqmm XLPE cable and LT sideterminal box shall be suitable for termination of 1000 Amps TPN Al. Bus Duct. The transformershall be supplied with all standard fitting viz thermistors for Alarm and Trip, winding temperaturerelay unit with Alarm and trip, lifting lugs, earthing studs and marshlling box, etc. complete in allrespect as required as per specification.

Set 2.00

HT & LT CABLES

122Supply, Laying in Open Duct/ Trench and Testing of following sizes of XLPE insulated PVCsheathed aluminium conductor armoured power cable of 11 kV grade as per IS 7098 and asrequired as per specifications.

a 3 Core 300 Sq.mm.metre 352.00

SUPPLY OF 1.1 kV GRADE LT CABLE

123Supplying of following 1100 volt grade XLPE insulated PVC inner sheathed and HR PVC outersheathed aluminium conductor armoured cables as per IS: 7098 and as required as perspecifications.

a 3.5 core 400 sq.mmmetre

b 3.5 core 300 sq.mmmetre 902.00

c 3.5 core 240 sq.mmmetre 210.00

d 3.5 core 150 sq.mmmetre 190.00

e 3.5 core 70 sq.mmmetre 132.00

f 4 core 25 sq. mmmetre 310.00

g 3.5 core 35 sq. mmmetre 300.00

124

Supplying of following 1100 volt grade PVC insulated sheathed copper conductor ametreouredcable as per specification in existing trenches, cable trays ducts over bed of sand, clampedincludes anchor fastners to wall with suitable clamps, saddles fixing bolts including connectingtesting and commissioning.

a 4 core 2.5 sq.mm control cablemetre 100.00

b 7 core 2.5 sq.mm control cablemetre 100.00

c 12 core 2.5 sq.mm control cablemetre 100.00

L.T. POWER CABLE END TERMINATION

125

Cable end termination of the following PVC insulated sheathed PVC/XLPE aluminium / copperconductor armoured cables of 1100 volt grade including supplying and fixing of crimpingaluminium lugs, double compression glands with earthing facility at both ends of cables etc.complete as required.

a 4 core 2.5 sq.mm control cableeach 4.00

b 7 core 2.5 sq.mm control cableeach 4.00

c 12 core 2.5 sq.mm control cableeach 4.00

126 MAIN LT PANEL CUM CHANGEOVER PANEL

Page 119: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of MainLT Panel cum DG Sysnchronizing panel fabricated out of 14 gauge CRCA sheet steel in cubiclecompartmentised free standing floor mounted, dust and vermin proof with reinforcement ofsuitable size angle iron, channel `T’ section and/ or flats wherever necessary. 3 mm thick cablegland plates shall be provided on top as well as at the bottom of the panel as per siterequirement. Panel shall be treated with all anticorrosive process before powder coating as perspecification and final approved shade. 2 No. earthing terminals shall be provided for the panel.Panel shall be suitable for 433 V, 3 phase, 4 wire, 50 HZ supply system, with extensible busbarson both sides, making suitable electrical/ mechanical interlocking arrangement betweenincomers & buscoupler breakers, interconnection, duly powder coated painting etc. includingsupply & installation of following switchgears, metering instruments and accessories as perspecifications. (All breakers breaking capacity shall be 50 kA. ICU = ICS). Lifting hooks shall alsobe provided in the panel.

Approval shall be taken for the panel in the form of shop drawings before fabrication. Galvanisedhardwares with zinc passivation shall be used in fabrication of panel.

Section - IINCOMER - 1 (630 kVA Transformer)Incoming for 1 No. 630 kVA Transformer comprises the following and as per single line diagram.

1000 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting as per specification and with followingaccessories :Digital energy meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-I, with 3Nos. 1000/5 amps 15VA CTs.Phase indicating light shall be protected by 2 amps MCB’s. - 3 SetThree Phase Under voltage relay MV12 or equivalnt (27) - 1 SetThree Phase Over voltage relay MV 12 or equivalent (59) - 1 SetBreaker ON/ OFF/ TRIP indicating lights with control MCB’s. - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.Three Phase Voltage sensor relay shall be protected by 2 amps TP MCB’s. - 1 SetTransient voltage surge supressor with suitable contactor shall be protected by 2 amps TPMCB’s. - 1 Set1 No. 1000/ 5, 15 VA dual ratio CT’s shall be provided for APFCR on transformer incomer.

BUSBARS1250 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy as perspecification.OUTGOING400 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting- 1 No. 400 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 400/5 Amps suitable VA, CL 1 CT - 2 No.

630 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 600/5 Amps suitable VA, CL 1 CT - 1 No.

Bus Coupler (1 ACB) shall be equipped with the following:

Page 120: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

1000A, 4 poles electrically draw out type motor operated air circuit breaker with microprocessorrelease unit (Type 2A of MG make or equivalent).24V D C shunt coil.415 under voltage release.1 No. 230 V A.C closing coil.Breaker control switch.On/ Off/ Trip indicating lamps.Spring charged indication.Section - IIINCOMER - II (630 kVA Transformer)Incoming for 1 No. 630 kVA Transformer comprises the following and as per single line diagram.

1000 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting as per specification and with followingaccessories :

Digital energy meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-I, with 3Nos. 1000/5 amps 15VA CTs.Phase indicating light shall be protected by 2 amps MCB’s. - 3 SetThree Phase Under voltage relay MV12 or equivalnt (27) - 1 SetThree Phase Over voltage relay MV 12 or equivalent (59) - 1 SetBreaker ON/ OFF/ TRIP indicating lights with control MCB’s. - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.Three Phase Voltage sensor relay shall be protected by 2 amps TP MCB’s. - 1 SetTransient voltage surge supressor with suitable contactor shall be protected by 2 amps TPMCB’s. - 1 Set1 No. 1000/5, 15 VA dual ratio CT’s shall be provided for APFCR on transformer incomer.

BUSBARS:1250 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy as perspecification.OUTGOING:400 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting- 1 No. 400 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 400/5 Amps suitable VA, CL 1 CT - 2 No.

250 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 600/5 Amps suitable VA, CL 1 CT - 1 No.

Main LT Panel cum Changeover Panel as described above.each 1.00

127 MAIN EMERGENCY PANELSection - IINCOMER - 1 (LT CUM DG CHANGEOVER PANEL)800 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting as per specification and with followingaccessories :

Digital energy meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-I, with 3Nos. 800/5 amps 15VA CTs.

Page 121: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

Phase indicating light shall be protected by 2 amps MCB’s. - 3 SetThree Phase Under voltage relay MV12 or equivalnt (27) - 1 SetThree Phase Over voltage relay MV 12 or equivalent (59) - 1 SetBreaker ON/ OFF/ TRIP indicating lights with control MCB’s. - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.Three Phase Voltage sensor relay shall be protected by 2 amps TP MCB’s. - 1 SetTransient voltage surge supressor with suitable contactor shall be protected by 2 amps TPMCB’s. - 1 SetINCOMER - II (500 kVA DG Set)Incoming for 1 No. 500 kVA DG set comprises the following and as per single line diagram.

800 amps 4 Pole electrically operated Manually drawout type air circuit breaker as perspecification and with following accessories.Control wiring from Synchronizing module (PCCM - 3100 or equivalent) at alternator.Electronic type energy meter (EM-6400 or equivalent with RS-485) of accuracy class 1.0 with 3Nos. 5 amps secondary CTsBattery charger with voltmeter of range 0-50 volts and ammeter of range 0-50 amps for trickleand boost charging.3 Nos. phase indicating lights with control MCB’s.Excitor field DC voltmeter and ammeter.Breaker control switch.Engine cranking relay.24 V DC shunt trip.Emergency stop push button.Selector switch for Auto / Manual / TestSelector switch for engine control OFF/ON.Five push buttons – start, stop, reset, test and accept.Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start’.12 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as requiredas per specification.Temperature scanner (Messi Bus/Procon)Phase sequence relay (46 )BUSBARS1000 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy as perspecification.OUTGOING630 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 600/5 Amps suitable VA, CL 1 CT - 1 No.

400 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 400/5 Amps suitable VA, CL 1 CT - 2 No.

200 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 200/5 Amps suitable VA, CL 1 CT - 1 No.

100 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 100/5 Amps suitable VA, CL 1 CT - 1 No.

Bus Coupler (1 ACB) shall be equipped with the following:

Page 122: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

800A, 4 poles electrically draw out type motor operated air circuit breaker with microprocessorrelease unit (Type 2A of MG make or equivalent).24V D C shunt coil.415 under voltage release.1 No. 230 V A.C closing coil.Breaker control switch.On/ Off/ Trip indicating lamps.Spring charged indication.Section - IIINCOMER - III (LT CUM DG CHANGEOVER PANEL)800 amps 4 pole electrically operated manually draw out type air circuit breaker withmicroprocessor release unit (Type 6A of MG make or equivalent), for short circuit, over currentand earth fault protection with adjustable setting as per specification and with followingaccessories :Digital energy meter (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-I, with 3Nos. 800/5 amps 15VA CTs.Phase indicating light shall be protected by 2 amps MCB’s. - 3 SetThree Phase Under voltage relay MV12 or equivalnt (27) - 1 SetThree Phase Over voltage relay MV 12 or equivalent (59) - 1 SetBreaker ON/ OFF/ TRIP indicating lights with control MCB’s. - 1 Set24 V DC Shunt trip coil. - 1 Set240 V AC under voltage release. - 1 SetAuto-manual / test selector / switch - 1 SetBreaker control switch - 1 SetAuxiliary contacts required for necessary interlocking of breakers.Three Phase Voltage sensor relay shall be protected by 2 amps TP MCB’s. - 1 SetTransient voltage surge supressor with suitable contactor shall be protected by 2 amps TPMCB’s. - 1 SetINCOMER - IV (500 kVA DG Set)Incoming for 1 No. 500 kVA DG set comprises the following and as per single line diagram.

800 amps 4 Pole electrically operated Manually drawout type air circuit breaker as perspecification and with following accessories.Control wiring from Synchronizing module (PCCM - 3100 or equivalent) at alternator.Electronic type energy meter (EM-6400 or equivalent with RS-485) of accuracy class 1.0 with 3Nos. 5 amps secondary CTsBattery charger with voltmeter of range 0-50 volts and ammeter of range 0-50 amps for trickleand boost charging.3 Nos. phase indicating lights with control MCB’s.Excitor field DC voltmeter and ammeter.Breaker control switch.Engine cranking relay.24 V DC shunt trip.Emergency stop push button.Selector switch for Auto / Manual / TestSelector switch for engine control OFF/ON.Five push buttons – start, stop, reset, test and accept.Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start’.12 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as requiredas per specification.Temperature scanner (Messi Bus/Procon)Phase sequence relay (46 )BUSBARS1000 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy as perspecification.OUTGOING

Page 123: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

630 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 600/5 Amps suitable VA, CL 1 CT - 1 No.

400 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 400/5 Amps suitable VA, CL 1 CT - 2 No.

250 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 250/5 Amps suitable VA, CL 1 CT - 1 No.

100 Amp TPN Moulded Case Circuit Breaker (Icu = Ics) with built in microprocessor basedrelease unit with adjustable setting including dual electronic energy meter (EM 6438 orequivalent with RS 485 port) with 100/5 Amps suitable VA, CL 1 CT - 2 No.

Main Emergency Panel as described above.each 1.00

128 FEEDER PILLARSDesign, Manufacturing, Supply, installation, testing and commissioning of cubicle type totallyenclosed free standing, dust free, damp and vermin proof and water proof outdoor (IP 54)Feeder pillar fabricated out of 2mm thick CRCA sheet duly powder coated and including supply &fixing the following items and interconnections, wiring with suitable size wires/cables andincluding all civil works like excavation, PCC, brick work pedestal, plastering, refilling etc. and asper specifications as required.

FEEDER PILLAR NO. 1 & 2 (EXTERNAL LIGHTING)Feeder Pillars for external lighting with IP-54Incomer : 1 no. 63 A TPN MCCB with 100A 4P insulated AL busbars. Out going : 24 Nos. 16/20 amps SP MCB as outgoing with 3 nos. 63 amps DP RCCB of 30 mAleakage current plus 1 No. 63 amps DP Contactor controlled through 0-24 hour timer.

Feeder Pillars described as above :Set 2.00

129 150 KVAR CAPACITOR AUTOMATIC CONTROL PANEL INCOMING400 amps TPN MCCB as per specification and with following accessories:96 x 96 mm sq. 0-500 Volt digital voltmeter with selector switch Phase indicating light shall be protected by 2 Amps SP MCB’s - 3 SetPower factor compensating relay (including power factor meter) in 8 steps for automatic cut offor add on capacitor units to keep the power factor at 0.97 with variation of loads. All associatedauxiliary contactors/ relays/ timer/ auto manual selector switches to be provided - 1 Set.

BUS BARS:500 amps TPN Aluminium bus bars with coloured heat Shrinkable insulated sleeves. - 1 set

OUTGOING - I:Outgoing feeders consisting of following accessories.63 amps TPN MCCB - 4 Set63 amps or capacitor duty 525 volts 50Hz contactors. - 4 Sets“ON” /”OFF” push buttons and indicating lamps. - 4 Sets25 KVAR, 525 volts capacitor unit with detune filters as specified - 4 SetsOUTGOING - II:Outgoing feeders consisting of following accessories.40 amps TPN MCCB - 4 Set40 amps or capacitor duty 525 volts 50Hz contactors. - 4 Sets“ON” /”OFF” push buttons and indicating lamps. - 4 Sets

Page 124: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

12.5 KVAR, 525 volts capacitor unit with detune filters as specified - 4 SetsNote:All MCCB’s shall be of 50 KA breaking capacity.Fast response time of ‘ON’ capacitors 40-60 miliseconds. Necessary control and firing card with proper wiring and lugs of the required rating to beprovided.Heavy duty exhaust fans to be provided for cooling Thyristors.LED indication for number of capacitor banks ‘ON’.LED indication of Power Factor lagging or leading.The APFC system shall be provided with following :Protections :a. Over voltage.b. Voltage imbalance.c. Over temperature-system should be in standby mode & automatically restart after abovecondition restored.d. Earth leakage.e. 7% value reactors with iron core.Capacitor automatic control panel (150 kVAr) as described above.

each 2.00

BATTERY & BATTERY CHARGER

130

Supply, Installation, Testing and Commissioning of 1 (One) number 24 V Battery Charger & 2(Two) numbers of 12V 200 AH maintenance free sealed lead acid batteries, Battery Chargershall be solid state, full wave fully controlled bridge, input suitable for single phase 230V ACsuppply, conforming to degree of protection IP-42, Sheet steel enclosure 2 mm thick withautomatic voltage regulation, current limiting circuitary, auto cut facility, smooth filter circuitswitches, Ammeter & voltmeter on DC side, phase indicating lamps (LED type) on AC sidecomplete in all respect with float and boost/ buck charging, switchgear, earthing, powder coatedpainting etc as required.

Job 1.00

131 Supplying of Rubber hand gloves suitable for 11 kV. Pair 2.00

132 Supplying and fixing of Shock treatment chart both in Hindi & English. each 4.00

133Supply and fixing Carbon dioxide fire extinguishers of 4.5 kg capacity each as per IS : 2878-1976 and mounting the same on wall by means of suitable hooks. each 4.00

134 Supply and fixing Dry Chemical fire extinguishers 5 kg as per IS : 2171-1976. each 2.00

135 Supply and fixing of 9 ltr mechanical foam type fire extinguisher each 2.00

136Supply and fixing 5No.Fire buckets 9 litre capacity filled with dry sand and fixed MS structure,made out of 40x6mm angle and hange with bracket . each 1.00

137Supply of First aid box containing material as prescribed by St. John Ambulance brigade ORIndian Red Cross complete as required. each 2.00

138

Supply & fixing of fire retardant/ extinguishing Electrical Insulated synthetic mat of 3.0 mm thick+/- 10% conforming to latest BIS: DOC NO. ET-02 (5440) meeting requirements of IS 3043, IS5216 (part-1, 2&3), IS 8437 and IEC 479, suitable for all voltages up to & including 33 kV ACand having minimum width of 1000 mm +/- 20 mm and including supply of required quantity ofadhensive / compound and fixing the same at site as per site requirement.

meter 10.00

139

Supply & fixing of fire retardant / extinguishing Electrical Insulated synthetic mat of 2.0 mmthick + 10% conforming to latest BIS: DOC NO. ET-02 (5440) meeting requirements of IS 3043,IS 5216 (part-1, 2&3), IS 8437 and IEC 479, suitable for all voltages not exceeding 3.3 kV ACand 220 V DC supply and having minimum width of 1000 mm +/- 20 mm and including supplyof required quantity of adhensive / compound and fixing the same at site as per siterequirement.

meter 25.00

Page 125: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

140

Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminiumsheet including lamination etc. as required complete including fixing the same on wall. Job 2.00

BUS DUCT (IN SANDWICH CONSTRUCTION)141 Supply, installation, testing and commissioning of following rating (50 KA for 1 Sec) TPN

busduct in sandwich construction of aluminium bus bars with expansion joints, fire barriersincluding necessary supports and louvers for ventilation, fabricated out of extruded aluminium/GI sheet painted with approved paint shade as per specification including 2 No. of 50 x 6 mmcopper earthing conductor through out the length of the bus duct. (Phase sequence shall bematched).Note: Degree of protection for outdoor bus duct shall be IP 55 as per IS:13947-1993.

a 1000 amps TPN bus ducts from Transformer - 1 toLT Cum DG & Tr. Changeover panel including90 deg bends. metre 10.00

b 1000 amps TPN bus ducts from Transformer - 2 to LT Cum DG & Tr. Changeover panel including90 deg bends. metre 16.00

c 800 amps TPN bus ducts from LT Cum DG & Tr Changeover Panel. to Emergency including 90deg bends. metre 28.00

d 1000 Amps TPN tinned copper flexible braided end connection on Transformer. each 2.00

e 1000 Amps TPN tinned copper flexible braided end connection on LT Cum DG & Tr ChangeoverPanel. each 2.00

f 800 Amps TPN tinned copper flexible braided end connection on Emergency Panel. each 2.00 EARTHING INSTALLATION (SUB STATION)

142 Supply, Testing & Commissioning, fixing of following bare GI tapes/ wires including all necessaryfixing accessories and effecting connections as per specifications.

a 50 x 5 mm thick GI. tape. metre 275.00 b 50 x 5 mm thick Cu. tape. metre 585.00

DG SETS FOR (UTILITY 1&2)143 1010 kVA DG Set

a

Supply, installation, testing and commissioning of 1010 kVA prime rating diesel generating set inacoustic enclosure radiator cooled with with PMG, base frame, Alternator, Static ExcitationSystem, Lube Oil System, Electronic Governor, Batteries, Instrumentation, day oil fuel tank,Residential Silencer with Bellows, Alarms, Engine Control Panel (PCC-3.3) AVM Pads, AVR Panel,Terminal Arrangements including cable termination box with all associated equipment/work asper specifications. Alternator shall have class H insulation and rated for 808 KW output at 47°C.Emergency stop push button for individual DG set shall be located at the canopy door. Engineshall not be derated upto 50°C ambient. No deration in DG set capacity shall be accepted on thisaccount.

each 3.00

144 500 kVA DG Set

a

Supply, installation, testing and commissioning of 500 kVA prime rating diesel generating set inacoustic enclosure radiator cooled with with PMG, base frame, Alternator, Static ExcitationSystem, Lube Oil System, Electronic Governor, Batteries, Instrumentation, day oil fuel tank,Residential Silencer with Bellows, Alarms, Engine Control Panel (PCC-3.3 or equivalent) AVMPads, AVR Panel, Terminal Arrangements including cable termination box with all associatedequipment/work as per specifications. Alternator shall have class H insulation and rated for 400KW output at 47°C. Emergency stop push button for individual DG set shall be located at the exitdoor. Engine shall not be derated upto 50°C ambient. No deration in DG set capacity shall beaccepted on this account. Note: Piping between day oil tank & DG set shall be included.

each 1.00

145 500 kVA DG Set

Page 126: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

a

Dismenteling,shifting, testing, commissioning & reinstallation as per drawing of 500 kVA primerating existing diesel generating set in acoustic enclosure with PMG, base frame, Alternator,Static Excitation System, Lube Oil System, Electronic Governor, Batteries, Instrumentation, dayoil fuel tank, Residential Silencer with Bellows, Alarms, Engine Control Panel AVM Pads, AVRPanel, Terminal Arrangements including cable termination box with all associatedequipment/work as per existing set complete as required.

each 1.00

146Auto Starting, Auto/Manual Synchronizing , Auto load sharing and loadmanaging panel and DG Auxiliary PanelSECTION IIncoming -1 for 1 No.1010 KVA DG sets each comprises the following and as per single linediagram.1600 amps 4P electrically operated fully drawout type air circuit breaker as per specification andwith following accessories.Wiring for Engine Generator control package relay type EGCP - 32 of woodward/ PCC-3.3 ofCummins or equivalent make at alternator with all accessories.Each incomer feeder shall be equipped with following accessories.Electronic type energy meter (EM-6400 or equivalent with RS-485 ) of accuracy class 1.0 with 3Nos. 5 amps secondary CTsBattery charger with voltmeter of range 0-50 volts and ammeter of range 0-50 amps for trickleand boost charging.3 Nos. phase indicating lights with control MCB’s.Excitor field DC voltmeter and ammeter.Breaker control switch.Differential protection relay (87) (3 Nos. L & T SC14S ) with PS class CT’s on both side ofalternator.Master trip relay.Trip circuit supervision relay.Engine cranking relay.24 V DC shunt trip.Emergency stop push button.Selector switch for Auto/ Manual/ Test.Selector switch for engine control OFF/ ON.Five push buttons – start, stop, reset, test and accept.Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start.12 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as requiredas per specification.Temperature scanner (Messi Bus/ Procon)Bus Bar :4000 A TPN electrolytic Aluminium bus bar with heat shrinkable insulation sleeve.Outgoings2500 amps TPN manually operated draw out type air circuit breaker with microprocessor releaseunit for short circuit, over current and earth fault protection with adjustable setting - 1 No.

Bus Coupler3200 amps 4P electrically operated fully drawout type air circuit breaker with microprocessorrelease unit for short circuit, over current and earth fault protection with adjustable setting - 1No.SECTION IIIncoming -2 for 1 No.1010 KVA DG sets each comprises the following and as per single linediagram.1600 amps 4P electrically operated fully drawout type air circuit breaker as per specification andwith following accessories.Wiring for Engine Generator control package relay type EGCP - 32 of woodward/ PCC-3.3 ofCummins or equivalent make at alternator with all accessories.Each incomer feeder shall be equipped with following accessories.

Page 127: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

Electronic type energy meter (EM-6400 or equivalent with RS-485 ) of accuracy class 1.0 with 3Nos. 5 amps secondary CTsBattery charger with voltmeter of range 0-50 volts and ammeter of range 0-50 amps for trickleand boost charging.3 Nos. phase indicating lights with control MCB’s.Excitor field DC voltmeter and ammeter.Breaker control switch.Differential protection relay (87) (3 Nos. L & T SC14S ) with PS class CT’s on both side ofalternator.Master trip relay.Trip circuit supervision relay.Engine cranking relay.24 V DC shunt trip.Emergency stop push button.Selector switch for Auto/ Manual/ Test.Selector switch for engine control OFF/ ON.Five push buttons – start, stop, reset, test and accept.Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start.12 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as requiredas per specification.Temperature scanner (Messi Bus/ Procon)Incoming - 3 for 1 No.1010 KVA DG sets each comprises the following and as per single linediagram.1600 amps 4P electrically operated fully drawout type air circuit breaker as per specification andwith following accessories.Wiring for Engine Generator control package relay type EGCP - 32 of woodward/ PCC-3.3 ofCummins or equivalent make at alternator with all accessories.Each incomer feeder shall be equipped with following accessories.Electronic type energy meter (EM-6400 or equivalent with RS-485 ) of accuracy class 1.0 with 3Nos. 5 amps secondary CTsBattery charger with voltmeter of range 0-50 volts and ammeter of range 0-50 amps for trickleand boost charging.3 Nos. phase indicating lights with control MCB’s.Excitor field DC voltmeter and ammeter.Breaker control switch.Differential protection relay (87) (3 Nos. L & T SC14S ) with PS class CT’s on both side ofalternator.Master trip relay.Trip circuit supervision relay.Engine cranking relay.24 V DC shunt trip.Emergency stop push button.Selector switch for Auto/ Manual/ Test.Selector switch for engine control OFF/ ON.Five push buttons – start, stop, reset, test and accept.Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start.12 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as requiredas per specification.Temperature scanner (Messi Bus/ Procon)Bus Bar :4000 A TPN electrolytic Aluminium bus bar with heat shrinkable insulation sleeve.Outgoings2500 amps TPN manually operated draw out type air circuit breaker with microprocessor releaseunit for short circuit, over current and earth fault protection with adjustable setting - 1 No.

Note:All outgoing feeders shall have suitable Digital ammeter with selector switch, CTs and phaseindicating light protected by 2 amps MCBs.

Page 128: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

All breakers shall be electrically interlocked as per schematic diagram. All ACB’s/MCCB’s shall be suitable for 50 KA breaking capacity.PLC for load management and supervision and D.G. set auxilliary.Auto starting / Auto synchronizing / Auto load balancing and auto load management panel for 3No. DG Sets as described above (component A to I complete as per specification) Set 1.00

HSD SYSTEM FOR DG SETS

147

S.I.T.C.of 20 KL underground Bulk Storage Tank .Fabrication of 6 mm thick M.S. plate withbracing inside complete with all standard appurtenances/ mountings like manhole of 600 mm dia& 450 mm dia cover duly hinged, access ladders, lifting lugs, earthing bolts etc. Plane ends of 8mm thick M.S. sheet, fuel fill pipe 80 mm dia with locking arrangement, vent pipe, outlet pipeBrass dip stick, with calibrater chart and two level indicators and controller. The tank shall beduly painted with two coats of tank mastic & two of coats of Tar Plastic paints outside of tankCivil works, tanker, fencing and earthing area not considered.

No. 2

148 Fuel Transfer gear Pump coupled with single phase flame motor (Set of 2 pumpsmounted on common base frame .

i For Supply No. 2

ii For Return No. 2

149 Fuel Piping

i 80mm dia MS "C" class pipe meter 10

ii 65mm dia MS "C" class pipe meter 100

iii 50mm dia MS "C" class pipe meter 50

iv 40mm dia MS "C" class pipe meter 50

v 25mm dia MS "c" class pipe meter 40

150 Wire braided flexible hose 5 meter with brass end fitting No. 1

151 Ball Valve - Sant - Brass

i Ball Valve 80 mm No. 5

ii Ball Valve 50 mm No. 5

iii Ball Valve 40 mm No. 4

iv Ball Valve 25 mm No. 11

152 Foot Valve 50 mm No. 2

153 Pot Stainer 80 mm No. 1

154 Y strainer

i Y Strainer 50 mm No. 2

ii Y Strainer 40 mm No. 2

155 NRV 50mm No. 2

156 NRV 40mm No. 2

157 Flow Meter - Mechanical Type

i Flow meter 80 mm No. 1

158 Flot Valve 50 mm No. 6

159 Level Sensor

Page 129: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

i Level Sensor for BMS (Buffer tank) No. 1

ii Level Sensor for BMS (Sump Tank) No. 1

160 Pressure Gauge with siphon and gauge cook No. 4

161 Day oil tank 990 liter No. 5

162 Buffer Tank 990 liter No. 1

163 Sump Tank 990 liter No. 1

164 MCC panel for Fuel system ( Outdoor type ) No. 1

165Safety equipment - Fire extinguisher, sand bucket etc. (Considereing 4 nos. 4.5 kg CO2 type fireExtinguishers, 8 nos. sand Bucket with stand)

Set 1

166 Statutory approval for Bulk Storage tank from Explosive Department Job 1

EXHAUST PIPE & CHIMNEY

167

Supply, installation, testing and commissioning of exhaust pipe fabricated out of 6 mm thick MSpipe class 'C' with all fixing accessories and hardwares. The exhaust pipes shall be insulatedwith 75 mm thick mineral wool insulation wrapped in chicken mesh and clad with 24 gaugealuminium sheet excluding all support as required.Above item shall be inclusive of all supportincluding angels, channels, ISMC supports, fasteners, bends,including painting etc. as requiredas per specifications..(Only MS guide support along with wall/shaft considered)

a 400 mm dia metre 35

b 250 mm dia metre 20

c 200 mm dia metre 30

d 125 mm dia metre 10

168

Supply and fixing of MS steel structure suitable for exhaust pipe fabricated out of 6 mm thick MSpipe. The structure shall be raised above 10 mtr. in height for fire clearance, self standing upto30 mtr, paint with heat resistant paint with all support, climbing ladder, finials for lightningprotection with GI tape and GI earthing station as required.

Kg 5,000.00

LT CABLES

169Supplying of following 1100 volt grade XLPE insulated PVC inner sheathed and HR PVC outersheathed aluminium conductor armoured cables as per specification as required as perspecifications.

Page 130: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

a 3.5 core 300 sq.mm metre 2000

170

Supplying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cableas per specification in existing trenches, cable trays ducts over bed of sand, clamped includesanchor fastners to wall with suitable clamps, saddles fixing bolts including connecting testing andcommissioning.

a 4 core 2.5 sq.mm control cable metre 300

b 7 core 2.5 sq.mm control cable metre 400

c 12 core 2.5 sq.mm control cable metre 200

L.T. POWER CABLE END TERMINATION

171

Cable end termination of the following PVC insulated sheathed PVC/XLPE aluminium / copperconductor armoured cables of 1100 volt grade including supplying and fixing of crimpingaluminium lugs, double compression glands with earthing facility at both ends of cables etc.complete as required.

a 4 core 2.5 sq.mm control cable each 10

b 7 core 2.5 sq.mm control cable each 10

c 12 core 2.5 sq.mm control cable each 10

BUS DUCT (IN SANDWICH CONSTRUCTION)

172

Supply, installation, testing and commissioning of following rating (50 KA for 1 Sec) TPNbusduct in sandwich construction of aluminium bus bars with expansion joints, fire barriersincluding necessary supports and louvers for ventilation, fabricated out of extruded aluminium/GI sheet painted with approved paint shade as per specification including 2 No. of 50 x 6 mmcopper earthing conductor through out the length of the bus duct. (Phase sequence shall bematched).Note: Degree of protection for outdoor bus duct shall be IP 55 as per IS:13947-1993.

a2500 amps TPN bus ducts from DG Sync. Panel to DG & Tr. Changeover panel including 90 degbends. metre 30.00

b 2500 Amps TPN tinned copper flexible braided end connection on DG Syn Panel. each 2.00

c2500 Amps TPN tinned copper flexible braided end connection on LT Cum DG & Tr ChangeoverPnael. each 2.00

EARTHING INSTALLATION (SUB STATION)

173 Supply, Testing & Commissioning, fixing of following bare GI tapes/ wires including all necessaryfixing accessories and effecting connections as per specifications.

a50 x 5 mm thick GI. tape.

metre 1,100.00

b50 x 5 mm thick Cu. tape.

metre 660.00

TOTAL OF SUB HEAD (C)

Page 131: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

SUB HEAD (D):IBMSCENTRAL CONTROL STATIONS

174Supplying, Installing, Testing & Commissioning of the Central Control Stations consisting of thefollowing :

a BMS workstation 'Intel 5, 3.2 GHZ Processor

3 GB RAM, 320 GB hard disc

DVD Read & writer, compatible CDROM

Windows XP and shall have MS-Office installed

As per specification

b 32” LCD screen minimum No. 1.00

c A4 laser printer Coloured No. 1.00

d Cordless Mouse No. 1.00

e Cordless Key board No. 1.00

SOFTWARE

175Supply, installation, testing & commissioning of following Software for Building ManagementSystem

aTesting and commissioning of the Software for Building Automation System i (Minimum Threeuser on LAN to be consider) Lot 1.00

b

Developing and commissioning of software interface with 85 No DEM / KWH/MFM/Trivectormeters for two way flow of data between central control station and static power meters.Theprice shall include the necessary integrator required for integration and also the networking of allload managers include network cabling.All necessary cabling (Communication / signal & power)from integrator / convertor to each equipment shall be included in the scope.

Lot 1.00

c

Developing & commissioning of Software interface for 1 No. PLC panel hook up to 3 No.VFD forSecondary Pump , 19 No for AHU, 6 CT VFD No. via communication bus.The price shall includethe necessary integrator / gateway required for integration and also the networking of allinclude network cabling. All necessary cabling (Communication / signal & power) from integrator/ convertor to each equipment shall be included in the scope.

Lot 1.00

d

Developing & commissioning of Software interface for 3 No. Chiller via communication bus.Theprice shall include the necessary integrator / gateway required for integration and also thenetworking of all include network cabling.All necessary cabling (Communication / signal &power) from integrator / convertor to each equipment shall be included in the scope.

Lot 1.00

e

Developing & commissioning of Software interface for 5 No. DG via communication bus.The priceshall include the necessary integrator / gateway required for integration and also thenetworking of all include network cabling.All necessary cabling (Communication / signal &power) from integrator / convertor to each equipment shall be included in the scope.

Lot 1.00

f

Developing & commissioning of Software interface with 9 No. UPS Panel via communicationbus.The price shall include the necessary integrator / gateway required for integration and alsothe networking of all include network cabling.All necessary cabling (Communication / signal &power) from integrator / convertor to each equipment shall be included in the scope.

Lot 1.00

No. 1.00

Page 132: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

g

Developing & commissioning of Software interface for VAV integrator (150 VAV) viacommunication bus.The price shall include the necessary integrator / gateway required forintegration and also the networking of all include network cabling.All necessary cabling(Communication / signal & power) from integrator / convertor to each equipment shall beincluded in the scope.

Lot 1.00

h

Developing & commissioning of Software interface with CCTV & Access system viacommunication bus.The price shall include the necessary integrator / gateway required forintegration and also the networking of all include network cabling.All necessary cabling(Communication / signal & power) from integrator / convertor to each equipment shall beincluded in the scope.

Lot 1.00

i

Developing & commissioning of Software interface with 4 No. Water Meter Panel viacommunication bus.The price shall include the necessary integrator / gateway required forintegration and also the networking of all include network cabling.All necessary cabling(Communication / signal & power) from integrator / convertor to each equipment shall beincluded in the scope.

Lot 1.00

j

Developing & commissioning of Software interface with 5 No.PAC unit Panel via communicationbus.The price shall include the necessary integrator / gateway required for integration and alsothe networking of all include network cabling.All necessary cabling (Communication / signal &power) from integrator / convertor to each equipment shall be included in the scope. The quotedprice for above shall be inclusive of communication cable in 25 mm dia MS conduit between theEquipment to Integrators /DDC Panel.

Lot 1.00

CONTROLLERS176 Supply, installation, testing & commissioning of the following:

a

Stand alone Intelligent DDC Controllers as per the specifications for I O points. The contractorshall decide upon the number of contollers, depending on his Controller capacity. Expandablemodules for Inputs/Outputs are not allowed.Contractor shall furnish quantity and unit rate foreach type of controller considered by him. The above shall be housed in a vandal proof, lockable& secure MS powder coated Cabinets to be supplied along with the Controllers.

Lot 1.00

bSystem Integration Units consisting of Gateways, Interface units as required The above shall behoused in a vandal proof, lockable & secure MS powder coated cabinets to be supplied along withthe Controllers

Lot 1.00

cSupply, installation, testing and commissioning of hand held portable operator terminals.(POT).These shall be required if the Controllers and Integration Units do not have a built in keypad onthe facia .

No. 1.00

Page 133: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

SENSORS & FIELD DEVICES177 Supply, installation, testing & commissioning of the following Sensors :

aResistance type immersion temperature sensors for measuring Chilled water, condenser watersupply and return temperature (Range 32-160 deg. F). The accuracy shall be at least ± 0.36degrees F. The pressure rating shall be 10 kgf/sq cm .

No. 9.00

bDuct Temperature & RH Sensor shall be with rigid stem type. These shall be suitable for ductinstallation and accuracy shall be at least ± 0.36 degrees F.

i Duct Mounted Temperature Type No. 36.00 ii Indoor Wall Mounted Type Temperature Sensor with Display No. 6.00 iii Duct Mounted Type Temp & RH Sensor No. 19.00 iv Wall Mounted Type Temp & RH Sensor with LCD display No. 1.00

c

Outside air temperature & humidity RH sensors for measuring outside air temperature (Range 35-130 °F). The accuracy of temperature sensor shall be ± 0.36 degrees F and RH sensor is ± 3%.It should be provided with sun sheild and rain protection.

No. 1.00

d

Pressure transmitters for measuring pressure in water headers (0-16 Kg/sqm).Pressuretransmitters shall be piezo-electric type or diaphragm type.Output shall be 4-20mA or 0-10VDC.Housing shall be weather proof with IP 65 protection.

No. 1.00

e Ultrasonic type inline type chiled water flow meter suitable for pipes (300 mm dia) No. 1.00

fDifferential pressure switches across the pumps for indicating the pumps status.The set pointshall fall in 40-70% of the scale range and shall have differentials adjustable over 10%-30% ofthe scale range.

No. 17.00

gDifferential pressure switches across the Air Handling Unit filters, for indicating the filter status.Pressure differential – 2 mm to 15 mm. The switch shall be with connecting tube and metalbends for connections to the duct.

No. 124.00

hDifferential pressure switches across the blowers for indicating blower status. Pressuredifferential – 10 mm – 125 mm. The switch shall be with connecting tube and metal bends forconnections to the duct. The housing shall be IP 54 rated.

No. 62.00

iLevel Switches for indicating Water level in water tanks. It should be of Single / Bi-Level FloatType/Capacitance type/Conductity type of Stainless steal construction. Housing shall be IP 55rated and output shall be 2 NO/NC

i1 Single Level Switch No. 6.00

i2 Bi- Level Switch No. 8.00

j Level Transmitters for monitoring water level in UG Tanks. No. 8.00

kWater Flow Switches shall be paddle type and suitable for the type of liquid flowing in theline. Output shall be 1 NO/ 1NC potential free as per specification No. 7.00

l Flame Proof Level Transmitter No. 1.00

m Flame proof Bi-level switch No. 11.00

n Duct Static Pressure Transmitters No. 19.00

o Electronic Water Meter (electromagnetic type) with Rs 485 communication port

o1 <=65 mm dia No. 4.00

VALVES AND ACTUATORS

178

Supply,and commissioning of motorized ON / OFF butterfly valves (PN16): inclusive of actuators,wiring & power supply.The actuator should accept 4-20 mA or 0-10 V signal from IBMS system &give position fedback to it. IBMS Contractor to check size of Valves and actuator fitting detailsbefore installation of following line sizes

Page 134: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

a 200 mm dia Valves. No. 3.00

b 250 mm dia Valves. No. 9.00

179

Supplying, installing, testing and commissioning of 2 x 1.0 mm signal / power cables UTPArmoured as per specification. (per I/O points hard wired to DDC). More than two cables shouldnot be saddled to wall /ceiling.

Per I/O point

780.00

180Supplying, installing, testing and commissioning of communication cables 2 C X 1.5 Sqmm STPArmoured). metre 9,360.00

181Supplying, installing, testing and commissioning of LAN cable cat 6 in 25 mm dia MS conduit(complete with all accessories) as per manufacturers recommendation. metre 50.00

182Supplying, installing, testing and commissioning of 2 mm thick GI perforated cable trays of thefollowing sizes complete with angle iron supports/hanging arrangement etc.

a 40 x 300 x 40 metre 300.00

b 40 x 200 x 40 metre 150.00

c 25 x 150 x 25 metre 200.00

TOTAL OF SUB HEAD (D)

SUBHEAD(E)- LIFT/ELEVATOR183 ELEVATOR :- Design, manufacture, supply, installation, testing, commissioning and

maintenance( each year maintenance price breakup as per Specification) of Machine Room Less(MRL) Passenger Elevator / Lift as mentioned in relavant BOQ item and as per specificification.1. Type of elevator: Passenger Elevator / Lift / Service Lift as mentioned in relavant BOQ item.2. Load carrying capacity: As mentioned in relavant BOQ item3. Speed: Varies (min 1.0 m / sec) 4. Openings: As mentioned in Drawing / BOQ (Glass Door)5. Stops / Floors: As mentioned in relavant BOQ item.6. Door operation: Full automatic power door with center/telescopic opening Glass doors7. Entrance Position: As specified (Through or Regular Type Car) 8. Finishes of Car wall & ceiling: Brush finished stainless steel, Anti skid granite / stone flooring 9. Operating panel: Stainless steel 10. For car: Call registration high intensity LED indicators with brail button indicator; Attendantoperations; Door open/close button; separate fan & light switch; Digital position & directionindicator; visual & audible indication for floors; Lighting of 53.8 lux,S.S. handrail on 3 side wall. 11. Car Door: Fully Automatic Doors S.S. hairline finish12. Car Door Protection: Multi beam height infra-Red Detection13. Car Operating Panel: Position indication, Call registration indication by illumination,Preannouncing arrows, Door open button, Door close button.

Page 135: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No

Description of Item Unit Quantity Rate in figures

(Rs.) Rate in words(Rs.)

Amount (Rs.)

14. For landings: Call registration high intensity LED indicators; Digital position & directionindicator; Visual & audible signals for call buttons. 15. Landing Operating Panel: Call registration indication by illumination, Car position indication,Pre-announcing arrows for direction, Overload indication,Full load incation, Fire indication, Out ofservice indication16. Lighting: Fluorescent LED lighting at front and rear wall in ceiling17. Ventilation: Fan18. Other features: Full length infra light curtain safety for Automatic door; Door nudgingoperation with buzzer; Built in voltage stabilizer for controller; Adjustable door opentime;Battery operated emergency light;Alametre and P&T between car & GF;Handrail on rearwall in car;Full height mirror on rear wall in car; Fireman switch at GF landing door; Intercomfrom car to controller; Attendant operation;Emergency light in car;Automatic rescue device withmaintance free batteries ;Alarm button in car19. Stainless steel Wall Cladding: At wall (Out side of car - Elevation) as instructed by Architect.

a Elevator - G+8, 8 Passenger Each 4.00 b Elevator - G+3, 12 Passenger Each 5.00 c Elevator - G+8, 13 Passenger Each 2.00

TOTAL OF SUB HEAD (E)

SUBHEAD(F)- GAS SUPRESSION

184 Supply, Installation, Testing and Commissioning of Novec-1230, 34.5 Bar, independent system for following rooms. Each system shall comprises of following system components including but not limited to; gas cylinder(s) with extinguishing agent, cylinder valve assembly, master cylinder kit with electrical actuation valve, manual actuator assembly, braided flexible hoses, warning plates, discharge nozzles, mounting brackets, gas release panel, multicriteria & photoelectric smoke detectors for cross zoning, manual release switch, abort switch, response indicator, fire survival cable, seamless discharge pipe to ASTM A-106, Such A-106 etc. The system shall be complete in all respect with gas qty and flow calculations approvals as required at site.

a 6 M x 13.08 M Data centre with room void of 3.1 M, Ceiling void of 0.80 M and Floor void of 0.30M Each 1

b 4.45 M x 9.05 M ICT networking room with room void of 3.1 M, Ceiling void of 0.80 M and Floorvoid of 0.30 M Each 1

c 5.70 M x 4.15 M UPS-1 with room void of 3.1 M, Ceiling void of 0.80 M and Floor void of 0.30 MEach 1

d 5.50 M x 4.15 M UPS-2 with room void of 3.1 M, Ceiling void of 0.80 M and Floor void of 0.30 MEach 1

e 5.75 M x 2.54 M UPS-3 with room void of 3.1 M, Ceiling void of 0.80 M and Floor void of 0.30 MEach 1

TOTAL OF SUB HEAD (F)

Total cost of NON Schedule Items-Electrical of Schedule-D

Page 136: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)

A.

1

54 °F

44 °F

0.0005 FPS

NON SCHEDULE ITEMS (HVAC WORK) SCHEDULE-F

Description of Items

EQUIPMENTSupplying, installing, testing and commissioning of CENTRIFUGAL WATER CHILLING UNITS eachcomplete with 400 TR capacity (total) Centrifugal compressor with Unit mounted (liquid /aircooled) factory fiited VFD, motor, starter panel machine mounted, water cooled condenser,insulated chiller, flow switch at chiller and condenser, vibration isolators, integral refrigerantpiping and power / control cabling from starter to unit, BMS interface unit (Tracer / Microgateway/ Datalink) grooved/flanged/victolic couplings for condenser and cooler water in/out connections,complete charge of refrigerant and oil, accessories as required and called for, automatic andsafety controls mounted in central micro-processor based console panel and all mounted on asteel frame complete as per specifications. Motor shall be suitable for 415±10% 50 cycles. 3phase AC supply and motor cable terminal box shall be suitable to connect Aluminium Cabling.Refrigerant used shall be Ozone friendly HFC-134a & R410a as detailed in specifications.All chillershall be factory tested at design conditions at 100%, 75%, 50% and 25% load(To ensureunloading of chillers and surge free operation). The Centrifugal chiller evaporator with secandoryvariable chilled water pumping system shall be designed to take minimum 40% of designed flow.The chillers shall be ARI certified.

Motor shall be suitable for 415±10% 50 cycles. 3 phase AC supply . Refrigerant used shall beOzone friendly HFC(R134a, R410a) as per specification.

Quoted price shall also be inclusive of:

a. Unit mounted automatic star delta/ soft starter to ensure that starting current shall not exceedtwice the full load current. b. Victolic coupling connection shall be provided for chilled and condensing water pipes.

Name of Work: Construction and development of Agri food cluster campus of National Agri-Food Biotechnology Institute (NABI) at Mohali(Punjab)

c. Chiller Installation in Basement.

d. Cable termination adopter box.

e. Marine boxes for chiller and condenser.

Chiller

LABORATORY

Chiller Water IN.

Chiller Water OUT.

Fouling Factor

Page 137: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

960 USGPM

88 °F

98 °F

0.001 FPS

1200 USGPM

- <0.65

NPLV - <0.4

No. 3a No. 3

b No. 3

c No. 3

d No. 3

e No. 3

2

2A Water flow rate 960 USGPM Head 40 Ft. of Water Maxm. Motor HP 15 HP

Included in item no.1

Included in item no.1

Included in item no.1

Included in item no.1

Included in item no.1

Chilling machines as described above (including one standby)

Supply imported portion of above chiller CIF nearest port and transportation of the same toMohali,Chandigarh.

Indicate for all chillers port charges, port handling charges, other local duties, loading, transportation/insurance upto site, octroi charges and all other taxes & incidentals complete till delivered at site. Custom duty & counterveiling duty against licence for the above imported equipments.

Receiving at site above imported equipment, unloading,storing,handling, hoisting,installing inposition, effective connections, anchoring, grouting above equipment including supplying &installing all necessory indageneous accessories to complete the installation.

Indicate for testing and commissioning of above machines.

Supplying, installing, testing and commissioning of CENTRIFUGAL VERTICAL INLINE PUMPS, factory mounted on a common base with electric motor for recirculation of water for the centralair conditioning system as per specifications. All pumps shall be aligned properly as required. Thepump motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply. The motorselected shall be energy efficient having efficiency (Class I) at full load ranging between 91.5% to94% in accordance with motor rating as per specification. Minimum pump efficiency shall be 75%.The motor of Secandory Variable chilled water pumps shall be suitable for operation on adjustablefrequency drive. The quoted price shall include cost of thermal insulation and cladding for item2A & 2B. Pumps with performance characteristics as given below:

Primary Chilled Water Pumps

Condenser

IKW/TR at 100% load b ti d

Minimum COP = 6.1

Chilled Water Flow

Condenser Water IN.

Condenser Water OUT.

Fouling Factor

Chilled Water Flow

Page 138: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

75 % or more

No. 3

2B

No. 32C

No. 32D

No. 3 3

Set 1

Efficiency Quantity indicated includes one standby ( PCHWP 1 - 3)

Secondary Chilled Water Pumps Water flow rate 960 USGPM Head 80 Ft. of Water Maxm. Motor HP 30 HP Efficiency 75 % or more Quantity indicated includes one standby (SCHWP 1 - 3 ) Hot Water Pumps Water flow rate 76 USGPM Head 110 Ft. of Water Maxm. Motor HP 5HP Efficiency 75 % or more Quantity indicated includes one standby (HWP 1 - 3 ) Condenser Water Pumps Water flow rate 1200 USGPM Head 70 Ft. of Water Maxm. Motor HP 30HP Efficiency 75 % or more Quantity indicated includes one standby ( CDWP 1-3 )

Supplying, installing, testing and commissioning of VARIABLE SPEED PUMPING SYSTEMconsisting of adjustable frequency drive (VFD) for 30 HP -3 Nos. pumps (2W+1SBY), onededicated microprocessor based pump controller per zone housed within the enclosure of one ofthe AFD with parallel pumping software duly down loaded and multiple differential pressuresensor / transmitters along with complete control cabling from transmitter to AFD Panel as perthe site requirement. The entire system along with primary / secondary pumps as describedunder item 5 / 9 must be sourced from single manufacturer only, to ensure unit responsibility.Necessary factory test certificates for entire system shall be submitted along with the equipment.Sensor / Transmitters as described in specification. System shall be BMS compatible with openprotocol communication port, so that complete data can be transported to remote IBMS console.

Page 139: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

3(a)

Set 1

4(a) No. 3

4(b)No. 1

4

b. MERV 8 filters in supply air stream. c. 6 Row deep cooling coil & 2 Row deep heating coil of copper tube and aluminum construction

sized at maximum face velocity of 500 fpm.

d. Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply meeting criterion as per ASHRAE standard 90.1-2010 and high efficiency.

5

e. Vibration isolators.

Supplying, installing, testing and commissioning of VARIABLE SPEED PUMPING SYSTEMconsisting of adjustable frequency drive (VFD) for 5 HP -3 Nos. pumps (2W+1SBY), one dedicatedmicroprocessor based pump controller per zone housed within the enclosure of one of the AFDwith parallel pumping software duly down loaded and multiple differential pressure sensor /transmitters along with complete control cabling from transmitter to AFD Panel as per the siterequirement. The entire system along with primary / secondary pumps as described under item 5/ 9 must be sourced from single manufacturer only, to ensure unit responsibility. Necessaryfactory test certificates for entire system shall be submitted along with the equipment. Sensor /Transmitters as described in specification. System shall be BMS compatible with open protocolcommunication port, so that complete data can be transported to remote IBMS console.

Supply, installing, testing and commissioning of horizontal FAN COIL UNITS (2 PIPESYSTEMS), blow thru type, each complete with 3 rows deep Chilled Water Coil, one or morecentrifugal fans, cleanable fabric filters, main condensate extended SS drain pans, RA insulatedplenum, as described in specifications, casing, coil piping connections, through copper pipes,condensate drain connections, wiring, control wiring in conduit upto thermostat boxes. Fan coilunit shall be factory fitted with valve package comprising of pressure independent Balancing cumControl Valve with integrated 2 way motorized actuator in a single body for modulating operationsuitable for static pressure of 1600 kPa and actuator shall be capable of withstanding 400 kPashut off pressure, 24 V AC incoming power supply, ball valve with Y-strainer at inlet & Ball valveat outlet and necessary copper coil piping connections. The actuator of modulating valve shall beprovided with interface cards to receive 0-10V or 4-20 mA signal from Digital Thermostat.

The actuator of the valve shall have necessary torque to overcome pressure differential of 4 barsrating. All fan coil units shall be suitable for 220±6% volts, 50 cycles, single phase power supply.Fan coil units shall be of following refrigeration capacities as listed.

1.0 TR nominal capacity - 400 CFM

2.5 TR nominal capacity - 1000 CFM

Supplying, installing, testing and commissioning of double skin construction draw thru type AIRHANDLING UNITS as per specification, each complete with following:

a. Direct drive supply air centrifugal backward curved fan.

Page 140: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Tag No. Floor Space Type CFM TR5.1 AHU- 1 Ground FB Cabins &

Passage CSU 3500 8.5

No. 1 5.2 AHU- 2 Ground Plant biotech 2 FMU 14000 27

No. 1 5.3 AHU- 3 Ground NMR & Central

Store FMU 15500 31

No. 1 5.4 AHU- 4 Ground Corridor 1 CSU 5000 10

No. 1 5.5 AHU- 5 Ground Corridor 1 CSU 3000 6

No. 1 5.6 AHU- 6 Ground Corridor 2 CSU 4600 9

No. 1 5.7 AHU- 7 Ground DH Atrium &

Reception FMU 13000 24

No. 1 Tag No. Floor Space Type CFM TR

5.8 AHU- 8 First Director's Office CSU 4800 10 No. 1

5.9 AHU- 9 First Bio Informatics FMU 16500 37 No. 1

5.10 AHU- 10 First Plant biotech FMU 19500 41 No. 1 5.11 AHU- 11 First Admin & Admin

Staff FMU 11000 23

No. 1 5.12 AHU- 12 First Corridor 1 CSU 3500 6 No. 1 5.13 AHU- 13 First Corridor 2 CSU 4500 9 No. 1 5.14 AHU- 14 First Corridor 3 CSU 5000 10 No. 1 5.15 AHU- 15 First Prefunction

Room CSU 1500 4

No. 1

f. Fan outlet velocity not exceeding 10 mps.

g. Minimum 20 mm (WC) external static pressure after sound attenuators. Total static pressureof AHU shall be checked by Vendor. h. Sound level at 1m distance not exceeding 60 dB in supply and return air stream. Sound

attenuators in supply and return air streams shall be provided if required to meet the specifiedsound level in both supply & return air ducts.

i. VFD designed for HVAC applications for supply air fan with built-in PID controller, control panel(keypad & display) , IP-55 enclosure for use on standard centrifugal fans. The VFDs should notcause any deration of the connected motors and must ensure that class B temperature levels ofthe connected motors are never exceeded. The display should be in alpha-numeric characters andprogramming facility should be in user-friendly HVAC terminology. VFD’s shall have builtinharmonic filters.VFD shall be BMS compatible with open protocol communication port, so thatcomplete data can be transported to remote IBMS console.

Max Heating 2 3

7.5 30

7.5 2

2 Nil

1 Nil

2 Nil

7.5 1

Max Heating 2 7

7.5 38

10 505 13

2 Nil2 Nil2 Nil1 Nil

Page 141: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

5.16 AHU- 16 First 35 Seater Conference Room

CSU 1300 4

No. 1 5.17 AHU- 17 Second Dean Office CSU 4800 10 No. 1 5.18 AHU- 18 Second Plant Biotech FMU 20500 45 No. 1 5.19 AHU- 19 Second Non Clean Room

Nutrition Btech CSU 6000 14

No. 1 5.20 AHU- 20 Second Seminar Rooms FMU 12000 27

No. 1 5.21 AHU- 21 Second 130 Seater

Conference Room

FMU6000 15

No. 1 5.22 AHU- 22 Second Corridor 1 CSU 3500 6 No. 1 5.23 AHU- 23 Second Corridor 2 CSU 4500 9 No. 1 5.24 AHU- 24 Second Corridor 3 CSU 5000 10 No. 1 5.25 AHU- 25 Second High

Tea/Prefunction CSU 2600 6

No. 1 5.26 AHU- 26 Third Administration FMU 5500 10 No. 1 5.27 AHU- 27 Third Plant biotech 1 FMU 21500 50 No. 1 5.28 AHU- 28 Third Plant biotech 2 FMU 24000 55 No. 1 5.29 AHU- 29 Third Corridor 1 CSU 3500 6 No. 1 5.30 AHU- 30 Third Corridor 2 CSU 5000 10 No. 1 5.31 AHU- 31 Third Corridor 3 CSU 5200 10 No. 1 5.32 AHU- 32 Ground Food Biotech FMU 14000 21 No. 1

6

1 Nil

2 710 502 18

5 3

29

2 Nil2 Nil2 Nil1 Nil

2 310 3510 452 Nil2 Nil2 Nil

7.5 14 Note 1 : AHU No- 1, 2, 3, 7, 8, 9, 10, 11, 17, 18, 19, 20, 21, 26, 27, 28 &32 only to be Note 2 : AHU No- 2, 3, 9, 10, 18, 19, 27,28 & 32 only to be provided with standby fan Double skin AHU (in Single /double Decker construction) complete with thermal breakprofile, Fresh air section with Fresh air manual AL damper with double HDPE insect mesh, Filtersections with G-4 filters & F6 /F9 filters (The Velocity across F6 filters not to exceed 500 FPM),Coil section with CHW coil, PVC Moisture Eliminator,DIDW backward Curved Centrifugal Blower ,Supply air plenum with Supply air manual AL damper, Return Air plenum with return air manualAL damper, Differential pressure nozzles, Exhaust air manual AL damper with double HDPEinsect mesh, Magnehelic gauges with pvc tubing across all filters & blower, Service windows asper approved design & Motor for Supply air blower.The filter stages shall be as specified in theahu data sheet.EU 13 filters if specified shall be terminal mounted and rates for the same to bequoted as specified under respective items under filter housing/hooded filters.

Limitswitches in Supply fan section for AHU doors and Inspection lamp, Cushy foot mountings, Fire proof double canvass connections (Fungal resistant and Lint free) and Standard accessories duly

Page 142: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Tag No. Floor Space Type CFM TR Max

Motor (HP)

Bypass Air Qty

(CFM)

humidifier

Capacity (Litre/h

our)

Heating

Capacity

(KW)

6.1 AHU- 32 Ground Clean Labs-GC,LC-MS erc.

FMU 21500 25 30 3600 5 28 No. 1

6.2 AHU- 33 Ground Plant biotech 1(Clean room)

FMU 15000 17 20 4600 5 20 No. 1

6.3 AHU- 34 Second Clean RoomNutrition Btech

FMU 15500 17 20 4600 10 21 No. 1

a.6 Row deep cooling coil & 2 Row deep heating coil of copper tube and aluminum construction sized at maximum face velocity of 500 fpm.

b. Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply meeting criterion as per ASHRAE standard 90.1-2010 and high efficiency.

c. Vibration isolators. d. Fan outlet velocity not exceeding 10 mps. e. Minimum 60 mm (WC) external static pressure after sound attenuators. Total static pressure of AHU shall be checked by Vendor.

f. Constant Volume Coil Bypass damper of specified bypass air quantity in below mentioned table,to be provided in the AHU's.

g. VFD designed for HVAC applications for supply air fan with built-in PID controller, control panel(keypad & display) , IP-55 enclosure for use on standard centrifugal fans. The VFDs should notcause any deration of the connected motors and must ensure that class B temperature levels ofthe connected motors are never exceeded. The display should be in alpha-numeric characters andprogramming facility should be in user-friendly HVAC terminology. VFD’s shall have builtinharmonic filters.VFD shall be BMS compatible with open protocol communication port, so thatcomplete data can be transported to remote IBMS console.

Note 1: Other than the heating coil pecified in AHU No.32, there are two duct heaters of 3 KWeach required in duct branch feeding area ICP-MS & GC -TOF. The price for the same must beincluded in the cost of AHU. Note 2 : All above mentioned AHU's to be provided with addidtional/standby fan arrangement.as

Labs are 24 hours operational.

Page 143: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

7

Tag No. Floor Space CFM 7.1 TFA-1 Terrace Radioactivity

Rooms 3,000

No. 17.2 TFA-2 Ground Food Biotech Lab

Fresh Air 2,500

No. 18

Tag No. Floor Space CFM8.1 AHF-1 Terrace AHU's Fresh Air

Riser 1 11600

No. 18.2 AHF-2 Terrace AHU's Fresh Air

Riser 2 12800

No. 18.3 AHF-3 Terrace AHU's Fresh Air

Riser 3 6100

No. 18.4 AHF-4 Terrace AHU's Fresh Air

Riser 6 4700

No. 1

Supplying, installing, testing and commissioning of double skin construction draw thru typeTREATED FRESH AIR HANDLING UNITS as per specification, each complete with following :-

a. Supply air centrifugal Forward curved fan with efficiency >65% b. MERV 8 filters in supply air stream.

c. 8 Row deep cooling coil of copper tube and aluminum construction sized at maximum facevelocity of 500 fpm.

d. Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply meetingcriterion as per ASHRAE standard 90.1-2010 and high efficiency.

e. Vibration isolators.

f. Fan outlet velocity not exceeding 10 mps.

g. Minimum 20 mm (WC) external static pressure after sound attenuators. Total static pressureof AHU shall be checked by Vendor.

h. Fan belt drive package

j. All air handling units to be provide with SS-304 end plates for coil.centrifugal fans.

Motor (HP) 1

1

Supplying, installing, testing and commissioning of AIR HANDLING UNITS ( FAN SECTIONSONLY)with double skin construction as per specificatopns, each complete with squirrel cageinduction motor (mounted internally), airfoil centrifugal fan belt drive and vibrationsisolators.Motors shall be suitable for 415 +- 10% volts, 50 cycles , 3 phase AC supply an staticpressure shall be as indicated . Fan-motor assembly (as whole) shall be statically & dynamicallybalanced to grade G6.3 as per ISO-1940/AMCA 204-3. All AHUS (Fan sections) shall be suitablefor outdoor duty and complete with duct flexible connections and volume control damper . Inadditional all supply fans (SF) shall be provided with prefilter .Minimum 20 mm (WC) externalstatic pressure . Total static pressure of AHU shall be checked by Vendor.

Motor (HP)5

5

2

1.5

Page 144: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

8.5 AHF-5 Terrace RadioactivityRoom Exhaust

3000 No. 1

8.6 AHF-6 Terrace Toilet Exhaust 3200 No. 3

8.7 AHF-7 Terrace RNA And ColdRoom Exhaust

1400 No. 1

9

9.1 No. 5

9.2 No. 5

9.3 No. 7

9.4 No. 23

9.5 No. 7

9.6 No. 10

No. 35

No. 411

Fan Tag Description

Space Fed Floor CFM

10

80 mm dia

1

1

1

Supply, installation, testing and commissioning of Electronic Self Balancing Valve pressure independent with independent type dynamic balancing valve for AHUs with integrated 2 waymodulating control valves in a single body. The actuator shall be capable of accepting 2-10 VDC /4-20 mA electric signal and shall provide similar transduced feedback output signal to controlsystem for flow measurement. The minimum close off pressure actuator must be 1.5 times shutoff head of pump 5 bars whichever is maximum. The valves shall be suitable for following pipesizes:

65 mm dia

50 mm dia

Supply, installation, testing and commissioning of cooling Thermostats for various air handling units and fan coil units.

Supplying, installing, testing and commissioning of Smoke extract fans as per specifications.Fan shall be with direct driven vane axial fan. Fan and casing shall be suitable for smoke exhaustapplication.Motor shall be mounted inside/outside so that it is not exposed to smoke stream &thermally rated for 250 Deg C for 2 hour as per [BS-7346 Part-2 : 1090] Class-H. Motors shall besuitable for 415+10% volts, 50 cycles , 3 phase AC supply with high efficiency,EFF-2 type andstatic pressure shall be as indicated.Minimum 20 mm (WC) external static pressure after fanoutlet. Total static pressure shall be checked by Vendor.The fan shall be equipped with mountingbracket & outlet core required at discharge.Fan shall be with flexible fire proof connection at inletand outlet.Cost of spring isolators for the installation of the fans needs to be included.Fan capacityshall be as follows:-

Motor HP

32 mm dia

25 mm dia

20 mm dia

i. Proportional cooling thermostat at AHU.

ii. Proportional cooling thermostat at FCU.

Page 145: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

11.1 VEX-1 Exhaust Air

Clean room Lab Ground 6500 No.

1

11.2 VEX-2 Exhaust Air

Food Biotech Lab Ground 4500 No.

1

11.3 VEX-3 Exhaust Air

Plant Biotech Ground 7500 No.

1

11.4 VEX-4 Exhaust Air

NMR Ground 11000 No.

1

11.5 VEX-5 Exhaust Air

Bio Informatics Lab

First 12000 No.

1

11.6 VEX-6 Exhaust Air

Plant Biotech First 7500 No.

1

11.7 VEX-7 Exhaust Air

Plant Biotech Second 14000 No.

1

11.8 VEX-8 Exhaust Air

Nutrition Biotech Second 5500 No.

1

11.9 VEX-9 Exhaust Air

Plant Biotech 1 Third 14000 No.

1

11.10 VEX-10 Exhaust Air

Plant Biotech 2 Third 13000 No.

1

11.11 VEX-11 Exhaust Air

DH Conference Room

Second 10000 No.

1

11.12 VEX-12 Exhaust Air

Food Biotech Ground 6500 No.

1

1.5

1

1.5

3

3

1.5

3

1.5

3

3

2

1.5

Page 146: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

12

Description CFM12.1 Liftwell 10000

No. 412.2 Lift Lobby 14000

No. 312.3 Staircase

Pressurisation 11500

No. 312.4 Plumbing

Plantroom Fresh 4000

No. 112.5 LT Panel Room

Fresh & Exhaust Air

5500

No. 212.6 HVAC Plantroom

Exhaust 16000

No. 1

13

Tag No. Floor Space CFM13.1 IF-1 Ground Cold /Dark Room

Fresh Air 800

No. 1 13.2 IF-2 Ground Cold /Dark Room

Exhaust Air 800

No. 1

TAF-12 & 13

TAF-14

Supply, installation, testing & commissioning of AXIAL FLOW FAN suitable for installing in anyposition in Horizontal or vertical and complete with totally enclosed fan cooled motor belt drive,multi sheaved pulley mounted on motor and fan shaft, belt guard, motor mount and vibrationisolators. The fan shall be selected for low noise level and low RPM (less than 1000 RPM) Fanmotor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply with highefficiency,EFF-1 type. The fan shall be equipped with mounting bracket & outlet core required atdischarge. Minimum 15 mm (WC) external static pressure after fan outlet. Total static pressureshall be checked by Vendor.

Fan Tag Motor HP

TAF-1 to 4 2

TAF-5 to 7 5

TAF-8 to 10 3

TAF-11 1

1.5

5

Note : Liftwell,Lift Lobby & Staircase Pressurization fan shall be for outdoor application & provided with cannopy of material similar to casing.

Supplying, installing, testing and commissioning of INLINE FANS suitable for installing in anyposition in vertical or horizontal ducts. The casing shall be double skin, internally acoustically linedand constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted withmaintenance free external rotor motor. The motor shall be suitable for 220±10% volt singlephase 50 cycles AC supply. All units shall be complete with duct flexible connector and volumecontrol damper.

Page 147: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

13.3 IF-3 Ground Autoclave & Wash Area Exhaust

750

No. 1 14

14.1 No. 84

14.2 No. 3 14.3 No. 2 14.4 No. 2 14.5 No. 5 14.6 No. 9 14.7 No. 9 14.8 No. 25

15

15.1 No. 4

Integrator as described above for 40 number VAV Boxes.

Supplying, installing, testing and commissioning of Pressure Independent Variable Air VolumeTerminal units, suitable for installtion in horizontal ducts. The casing shall be double skinacoustically lined and constructed with galvanised sheet steel.Should include all accessories suchas single / multileaf damper (with equal % characteristics) etc. actuators, control cabling ,thermostat , feed back control cabling upto VFD panel / DDC Panel in AHU room and any otherancilary requirement for the functioning of the units. Cost of duct mounted Diff. pressuretransmitter with cabling upto VFD panel shall also be included.

VAV boxes shall be suitable for following air flow capacitties.

50 -499CFM

500 -590CFM

600-790 CFM

800 -990CFM

1101 -1500CFM

1501 -2000CFM

2001 -3000CFM

3001 -4000CFM

Note :

Quoted price shall include the following:

a. Motorized aluminium construction damper with actuator.

b. Differential pressure sensor

c. 220 volts power supply cord with 6 amp. Plug top up to the power socket

Supply, installation, testing and commissioning of INTEGRATOR for VAV boxes, capable ofgiving industry standard (Modbus / Lon Works / Bacnet) output to BMS system. Mapping shall berequired for monitoring individual room temperature for areas conditioned through VAV boxes.Quoted price shall be inclusive of wiring in GI conduit between integrator and individual VAVBoxes.

Page 148: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

16

No. 4 Unit described as above

Supply, installation, testing and commissioning of DUAL COIL MICROPROCESSOR BASEDPRECISION A/C UNITS as per the specifications complete with air cooled condenser, chilled watercoil and variable speed drive for condenser fan, scroll compressor, evaporator coil withhydrophillic coating, EC brushless motor, backward curved/ direct driven fan, first fill ofrefrigerent, 24 hrs performance test with necessary hea load, multistage electric heater, variablecapacity humidifer ,all valves ,accessories and vibration isolator. Motor shall be suitable for 415 +10% volts, 50 cycles, 3 phase AC supply and external static pressure shall be 25 Pa. Outdoor unitmotor should be with IP-54/55 protection and should be weather proof. PAC shall have bottomthrow.Auto sequencing of the unit for equal run time should be integral part of the micro-processor.

Each unit shall be complete with powder coated electrical panel and double earthing. The cablesshould be Cross linked polythene insulated, armoured Copper cabling, with a low smoke andflame sheath (XLPE/SWA/LSF) and all termination between main panel and PAC should havedouble compression gland. Timers shall be provided in Electrical panel for delayed start of units.

It shall be inclusive of copper, drain piping, control & power cabling from MCB to indoor unit & italso includes MCB, GI tray for supporting the refrigerant pipes( whereever exposed to sun)between indoor and outdoor units.

Units shall be equipped with factory integrated 2 way automatic control valve with thermostat. Itshall also provided with automatic balancing valve.

The unit capacities shall be after taking deration into account due to copper piping lengths.Condensers should be adequately sized for high ambient temperatures upto 43.3 Deg C withcondensing temperatures not exceeding 56 Deg C.

The unit should include INTEGRATOR for giving industry standard (Modbus / Lon Works / Bacnet)output to BMS system. Mapping shall be required for all points displayed on precision unitmicroprocessor panel. It shall be inclusive of wiring in MS conduit between integrator andindividual PAC panel.

CHW units shall be capable for delivering 8 TR actual sensible capacity at below rated chilledwater conditions : Chilled Water Inlet to PAHU's : 6.7 Deg C (44 Deg F)

Chilled Water Outlet from PAHU's : 12.2 Deg C ( 54 Deg F) Computerized selection sheet shall be required to be submitted along with the offer and same need to be demonstrated at the time of technical evalution. The air cooled units shall be complete with copper refrigerant piping with nitrile rubber insulation as per specifications. 8 TR Dual Coil (chilled water & DX air cooled) Microprocessor units for Server Room.

Page 149: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

No. 2 17

17.1No. 50

18

No. 1

No. 1 19

Capacity - Suitable for 400 TR Machine

300 mm dia.

3.5 TR (DX air cooled) Microprocessor units for Network Room.

Supply, installation, testing and balancing of Powder coated extruded aluminum construction jetdiffusers/nozzle with volume control dampers as per approved drawings and specifications.

Supplying, installing, testing and commissioning of PRESSURISED chilled& hot WATEREXPANSION TANK suitable for total volume of water in chilled water/ hot water circuits alongwith necessary accessories such as centrifugal air separator, pumps etc. in order to keep chilledwater system under (+) pressure and to prevent entrapment of pressure and to prevententrapment of air in the system. The tank shall be precharged steel expansion tank withreplaceable heavy duty butyl rubber bladder. The tank shall have 50 MM system connection and20 mm drain and charging valve connection to facilitate the on site charging of the tank to meetsystem requirement. The tank shall be fitted with lifting rings and a floor mounting skirt forvertical installation. The tank and air separator must be constructed in accordance with sectionVIII of the ASME Boiler and pressure vessel (Unfired)code and stamped 125 PSI workingpressure. The complete system shall be sourced from single manufacturer and supplied andinstalled with all accessories and safety fixtures and safety fixtures required for proper functioningof the complete hydronic system.

The total Volume of water in chilled water circuit = 2500 Litres for cooling system and static head of approximate 25 mts to be considered . The contractor shall submit calculations for total system volume and tank sizing calculations.

The total Volume of water in Hot water circuit = 300 Litres and static head of approximate 25 mts to be considered . The contractor shall submit calculations for total system volume and tank sizing calculations.

Supply, installation, testing and commissioning of INDUCED OR FORCED DRAFT COOLINGTOWERS. Fan and motor shall be suitable for VFD. Each tower shall be complete with basin,casing, distribution system, filling, louvers, ladder, fan and motor. Motor shall be suitable for415±10% volts, 50 cycles, 3 phase power supply, Isolator panel with MCCB at cooling tower andearthing, shall also be included. Tower for airconditioning system shall be selected on the basis ofambient wet bulb 80 Deg F. The tower shall be sized for 10% extra capacity over heat rejectionduty specified through water temperature difference and flow rate below :For units with VFD,complete equipment shall be designed to limit THDi to less than 5%.

Page 150: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Water flow rate

- 1200 USGPM

Water temp. IN.

- 98 °F

Water temp. out

- 88 °F

Recommended motor rating

- 10 HP X 2 Nos

Airside pressure drop

-

Type of motor

- IP55,TEFC

No. of cell - 1

No. 3

20

20.1 No. 4 20.2 No. 1

ii. Each VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption.

iii. Each VFD shall be installed in a dedicated external IP-55 enclosure and the inter connecting wires between driver and MCC shall be included.

Cooling tower as described as above (2 W & 1SBY) Note: i. VFD designed for HVAC applications for supply air fan with built-in PID controller, control panel(keypad & display) , IP-55 enclosure for use on standard centrifugal fans. The VFDs should notcause any deration of the connected motors and must ensure that class B temperature levels ofthe connected motors are never exceeded. The display should be in alpha-numeric charactersand programming facility should be in user-friendly HVAC terminology. VFD’s shall have builtinharmonic filters.

Supplying, installing, testing and commissioning of direct driven PROPELLER FANS for exhaust airas shown in drawings. Each fan shall be complete with permanent split capacitor or shaded polemotor, mounting plate, accessories like wire guard, bird screen and fixed louvers for weather

t ti i d F l ti t d El t i l h t i ti h ll b f ll 450 mm dia 900 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.

300 mm dia 900 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.

iv. Colour of cooling tower shall be as per Architect approval.

v. The cooling tower shall be of special design to suite are available at site as per design drawing.

Page 151: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

21

No. 2

B.22

a RM 200

b RM 145

c RM 725

d RM 500

23

a RM 410

b RM 264

c RM 154

d RM 935

e RM 666

Supplying, installing, testing and commissioning of Electrical Hot Water generator of vertical/horizontal construction equipped with sufficient number of flanges and electrical immersionheaters. The pressure vessel shall be constructed as per ASME standards and insulated on allsides with 100 mm thick fibreglass. The hot water generator shall be equipped with all automaticand safety controls such as manual reset high temperature water outlet, step controller andrecycling relay, ON-OFF switch, thermostats, pilot light, ‘ON’ status of individual banks, low watercut off all as per manufacturers recommendations. All basic controls and terminal shall be locatedin an internal control cabinet, factory wired and tested. The hot water generator shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply. The entire hot water generator and controlcabinet shall be factory assembled on common base and tested, requiring only connection toservices.

TOTAL OF SUB HEAD(A)

PIPING-CHILLED,HOT AND CONDENSER WATERProviding & fixing the following factory rolled MS pipes with specified wall thickness (as perspecifications) cut to required lengths and installed with all welded / grooved joints, providing andfixing in position necessary fittings like bends, elbows, tees, reducers, mating flanges, floormounted & ceiling/wall hung MS support & sockets for BAS, fabricated to size and shape inworkshop or brought out ready made where available of acceptable quality.

500mm dia MS pipes

450 mm dia MS pipes

a. Water ‘IN’ temperature : 104 deg F.b. Water ‘OUT’ temperature : 122 deg Fc. Heater Bank to be provided with 4 steps.

200 KW Hot Water Generator as described above.

300 mm dia MS pipes

250 mm dia MS pipes

Providing and fixing in position the following MS class ‘C’ pipes cut to required lengths (as perspecifications) and installed with all welded joints, providing and fixing in position the necessaryfittings like elbows, tees and reducers, mating flanges & sockets for BAS:

200 mm dia MS pipes

150 mm dia MS pipes

125 mm dia MS pipes

100 mm dia MS pipes

80 mm dia MS pipes

Page 152: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

f RM 259

g RM 310

h RM 138

i RM 799

j RM 195

k RM 637

24

a No. 3

b No. 3

c No. 3

d No. 18

e No. 18

f No. 8

g No. 2

h No. 9

i No. 15

j No. 32

k No. 22

25

a No. 3

b No. 3

c No. 4

d No. 1

e No. 1

f No. 1

g No. 1

h No. 1

i No. 1

j No. 1

26

a No. 48

b No. 16

65 mm dia MS pipes

50 mm dia MS pipes

40 mm dia MS pipes

32 mm dia MS pipes

25 mm dia MS pipes

20 mm dia MS pipes

Providing and fixing in position the following manual butterfly valves (PN 16) :

500 mm dia Valves.

400 mm dia Valves.

300 mm dia Valves.

250 mm dia Valves.

200 mm dia Valves.

150 mm dia Valves.

125 mm dia Valves.

100 mm dia Valves.

80 mm dia Valves.

65 mm dia Valves.

50 mm dia Valves.

Providing and fixing in position the following manual balancing valves (PN 16) :

250 mm dia Valves.

150 mm dia Valves.

125 mm dia Valves.

100 mm dia Valves.

80 mm dia Valves.

65 mm dia Valves.

50 mm dia Valves.

32 mm dia Valves.

25 mm dia Valves.

20 mm dia Valves.

Providing and fixing in position following ball valves (PN 16) :

32 mm dia valves

25 mm dia valves

Page 153: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

c No. 26

d

e No. 9

f No. 12

g No. 5

h No. 8

i No. 7

j No. 23

k No. 7

l No. 12

27

a No. 9

b No. 12

c No. 3

28

a No. 10

b No. 10

29

a No. 12

b No. 18

c No. 6

30 No. 15

31No.

3

32

No.

142

33

No.

118

34

No.

16

20 mm dia valves

Providing and fixing in position the following ‘Y’ Strainers (PN 16) :

250 mm dia Valves.

200 mm dia Valves.

80 mm dia strainers

65 mm dia strainers

50 mm dia valves

32 mm dia valves

25 mm dia valves

20 mm dia valves

Providing and fixing in position the following Non return Valves (PN 16) :

250 mm dia Valves.

200 mm dia Valves.

65 mm dia Valves.

Providing and fixing in position the following Drain Valves :

50 mm dia Valves.

25 mm dia Valves.

Supply, installation, testing and commissioning of flexible connections of suitable pressurerating to be installed at pump suction, discharge and at pipes crossing building expansion joints.

250 mm dia pipes (PN-16)

200 mm dia pipes (PN-16)

65 mm dia pipes (PN-16)

Supplying, installation, testing and commissioning of Auto air vents(PN-16).

Supplying, installation, testing and commissioning of Flow Switches .

Providing and fixing in position SS 304 the industrial dial type pressure gauges with gun metalvalves.

Providing and fixing in position SS 304 the mercury-in- glass industrial dial typethermometers.

Supply, installation, testing and commissioning of Magnehelic Gauges 100mm dial, range 0 to60 Pa with SS box, probes & tubes, at different rooms

Page 154: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

35

a RM 130

b RM 30

cRM

20

36

a No. 1

b No. 1

c No. 1

C.

37

aSqm 7,053

bSqm 2,663

cSqm 673

dSqm 933

eSqm 176

38

aSqm 200

bSqm 63

39

aNo. 62

bNo. 24

Providing and fixing in position the following GI class ‘B’ pipes cut to required lengths and installedwith all screwed joints, and providing and fixing in position the necessary elbows, tees andreducers as per specifications for AHU / FCU drain.

Providing and fixing in position the following ‘POT’ Strainers :

50 mm dia GI pipes

32 mm dia GI pipes

25 mm dia GI pipes

Suitable for 500 mm dia pipe

TOTAL OF SUB HEAD(B)

Supply, installation and testing of Factory fabricated GI sheet metal ducts as per SMACNA inaccordance with the approved shop drawings and as per specifications.

Suitable for 450 mm dia pipe

Suitable for 100 mm dia pipe

AIR DISTRIBUTION

26 gauge galvanised sheet steel (0-750mm)

24 gauge galvanised sheet steel (751-1200mm)

22 gauge galvanised sheet steel (1201-1800mm)

20 gauge galvanised sheet steel (1801-2100mm)

18 gauge galvanised sheet steel (2101 & Above)

Supply, installation and testing of Factory fabricated Aluminium sheet metal ducts as perSMACNA in accordance with the approved shop drawings and as required by the specifications.

Supply, installation, testing and commissioning of Aluminum Powder Coated Risers with filterfixing arrangement & opening complete with perforated grill & bolts in front.

450mm X 150 mm (3.5m Vertical Length)

450mm X 300 mm (3.5m Vertical Length)

22 gauge

24 gauge

Page 155: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

40

Sqm 1141

Sqm 4242

Sqm 1643

Sqm 1344

aSqm 32

bNo. 64

45

Sqm. 8646

Sqm. 8847

Sqm. 848

Sqm. 549

Sqm. 450

Sqm. 3

Supply, installation, testing and balancing of powder coated extruded aluminium Air Grilles frontfixed type with inner side adjustable/movable type without volume control dampers.

Supply, installation, testing and commissioning of motorised combined smoke & fire dampercomplete with control panel, inter connecting wiring at locations shown in approved shop drawingsand as per specifications.

Supply, installation, testing and balancing of Powder coated extruded aluminium constructionsquare / round shape supply air diffusers with removable core & anti smudge ring & volumecontrol dampers as per approved drawings and specifications.

Supply, installation, testing and balancing of Powder coated extruded aluminium construction.Square / round shape return air diffusers with removable core, antismudge ring & withoutvolume control damper as per specifications.

Supply, Installation, Testing and Balancing of Powder coated extruded aluminium constructionLinear Grilles with removable core as per approved drawings and specifications. Quoted priceshall be inclusive of volume control damper behind supply air collar.

Supplying & fixing of opposed blade volume control dampers in supply air duct collars as perapproved drawings and specifications.

Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminiumconstruction. louvers with bird screen for exhaust air as per specifications and approveddrawings.

Smoke & Fire Damper

Control Panel & Wiring(with actuators)

Supply, installation, testing and commissioning of Low leak aluminium damper in return airducts for rooms of classified areas.

Supply, fabrication, installation and testing the flexible connections constructed of fire resistantdouble resin sleeve as per the approved shop drawings.

Supply, installation, testing and balancing of powder coated Extruded Aluminium supply air Grillesfront fixed type with inner side adjustable/movable type with volume control dampers inaccordance with the approved shop drawings and specifications.

Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminiumconstruction. louvers with bird screen for fresh air as per specifications and approved drawings.

Page 156: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

51

aSqm 8

bNos. 10

52

aNo. 88

D.53

a Sq.m. 200

54

a Sq.m. 9275

b Sq.m. 20

55

aRM 138

bRM 799

cRM 195

Supply, installation, testing and commissioning of motorized volume control ON /OFF typedampers of extruded aluminium construction in fresh air/return air/exhaust air steams. Thedamper actuator must accept signal from BMS system. Maximum leakage rate from dampersshall be in accordance with AMCA standard 500 . Quoted price shall also be included control wiringof damper.

Hooded Type Terminal Hepa Filter Box with Filter & filter shall be gel seal type & replaceablefrom Room side, Frame material: Aluminum anodised, Dop efficiency:99.997% down to 0.3micron with SS Terminal Plate

TOTAL OF SUB HEAD (C)THERMAL INSULATION

Motarised Damper

Control Panel & Wiring(with actuators)

Hepa Filter boxes shall be of following sizes.610 x 610 x 133 (700 CFM)

Supply, installation testing and commissioning of acoustic insulation. Material shall be Open cellNitrile rubber and all accessories as per specification.

Supply and installation of External Thermal closed cell crosslinked polyethelene/Nitrile rubberinsulation for Class O as per BS 476 Part 6 : 1989 with aluminium foil faced & Self adhesivebacking on ducts as per the approved specifications. Quoted price shall be inclusive of UVprotective coating over exposed to weather ducts.

Supplying, installing and testing of 25 mm thick (pre-moulded pipe section of T.F. qualityexpanded polystyrene, 24 Kg / M³) insulation on chilled water and condensate drain piping andfitting like valves, flanges union etc. as per the approved shop drawings and specifications.

15 mm thick acoustic lining

13 mm thick insulation for supply & return air ducts

25 mm thick insulation for supply & return air ducts exposed to weather.

40 mm dia pipes

32 mm dia pipes

25 mm dia pipes

Page 157: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

dRM 637

eRM 130

fRM 30

gRM 20

56

aRM 264

bRM 154

cRM 935

dRM 666

eRM 259

fRM 310

57

aSqm 204

bRM 724

cRM 418

dRM 385

Supplying, installing and testing of 50 mm thick (pre-moulded pipe section of T.F. qualityexpanded polystyrene, 24 Kg / M3) insulation on chilled water piping and fitting like valves,flanges union, etc. as per the approved shop drawings and specifications.

20 mm dia pipes

50 mm dia condensate drain pipes

32 mm dia condensate drain pipes

25 mm dia condensate drain pipes.

150 mm dia pipes

125 mm dia pipes

100 mm dia pipes

80 mm dia pipes

Supplying, installing and testing of 75 mm thick (pre-moulded pipe section of T.F. qualityexpanded polystyrene, 24 Kg / M3) insulation on chilled water piping and fitting like valves,flanges union, etc. as per the approved shop drawings and specifications.

TOTAL OF SUB HEAD (D)

65 mm dia pipes

50 mm dia pipes

450 mm dia pipes

300 mm dia pipes

250 mm dia pipes

200 mm dia pipes

Page 158: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

E.

i

ii

iii

iv

v

vi

vii.

viii

58

Digital VAF meter with 3 No.1250/5 amps 15VA CTs with inbuilt slector switch.

Phase indicating light shall be protected by 2 amps MCB’s. - 3 Sets

ON / OFF indicating lights with control MCB’s. - 1 Set.

Under voltage release - 1 Set

24 V DC Shunt trip coil. - 1 Set

Auto-manual / test selector / switch - 1 Set

Digital electronic Demand controller (EM 3460 with RS-485 ) suitable for metering class CT’s

Auxiliary contacts required for necessary interlocking of breakers.

MOTOR CONTROL CENTRE FOR AIR CONDITIONING EQUIPMENT

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type2 mm thick sheet steel enclosed separate compartment for each feeder, front operated, rearconnections indoor type LT motor control panel, dust and vermin proof, drawout/hinged andlockable doors, complete with internal wiring, colour coding with ferrules, cable glands, bonding toearth and painting. Quoted price for each panel & motor control centre shall include all powercabling & earthing over MS Powder coated cable trays upto various equipment/motor and allassociated control wiring.

All outgoing shall be provided with Stop/Manual/ Auto/selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

2 No. 1250 Amps 4 pole electrically operated fully drawout type air circuit breaker withON/OFF/TRIP indicating lumps with MCB's and over current short circuit and earth faultmicroprocessor releases (Type 2A of MG or equivalent make) .

Motor Control Centre 415V consisting of

Incoming

ELECTRICAL PANELS

1250 Amps 4 pole electrically operated fully drawout type air circuit breaker without release withON / OFF indicating lamps with control MCB’s and breaker control switch etc. complete asrequired. - 1 Set

Bus Bars1600 amps TPN Aluminium bus bars with colour coded heat shrinkable insulating sleeves - 1 Set.

Bus Coupler

Outgoing

Page 159: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 1

3 No. 800 amps TPN MCCB as outgoing for 3 No. 260 KW starter of chilling unit compressor motor . The MCCB compartment shall contain CT operated digital ammeter of 0-800 amps rangewith selector switch and an indicating lamp with MCB for ‘ON’ status of motor.

1 No. 630 amps TPN MCCB as outgoing for 2 No. 200 KW starter of Hot water Generator . TheMCCB compartment shall contain CT operated digital ammeter of 0-630 amps range with selectorswitch and an indicating lamp with MCB for ‘ON’ status of motor.

3 No. MPCB, suitable rating Star Delta starter for 15 HP motor, over load relay with built in singlephasing protection and outgoing feeder to Primary chilled water pump motor. Thecompartment shall contain an indicating lamp with MCB for ‘ON’ status of fan motor.

3 No. MPCB, suitable rating Star Delta starter for 30 HP motor, over load relay with built in singlephasing protection and outgoing feeder to Condenser water pump motor. The compartmentshall contain an indicating lamp with MCB for ‘ON’ status of fan motor.

3 No. MPCB, suitable rating VFD starter for 30 HP motor, over load relay with built in singlephasing protection and outgoing feeder to Secondary water pump motor with VFD. Thecompartment shall contain an indicating lamp with MCB for ‘ON’ status of fan motor.

3 No. MPCB, suitable rating VFD starter for 5 HP motor, over load relay with built in singlephasing protection and outgoing feeder to Hot water pump motor with VFD. The compartmentshall contain an indicating lamp with MCB for ‘ON’ status of fan motor.

3 No. MPCB, suitable rating VFD starter for 2 No. 10 HP motor, over load relay with built in singlephasing protection and outgoing feeder to Cooling. Tower Fan Moter water pump motor. Thecompartment shall contain an indicating lamp with MCB for ‘ON’ status of fan motor.

c. Necessary cable alleys, space for spare switches, internal wiring, and copper earthing ofequipment shall also be included. All switches and other components shall be motor duty rating.

Motor Control Centre as described above.

Note :Motor Control Centre No. 1 shall be suitable for 50 KA fault current.

Page 160: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

aNo. 4

bNo. 11

59

60

a. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA.

b. DOL / SD starter as per HP ratings

c. Terminal block for power distribution.

j. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.k. All starters shall be provided with suitable potential free contract for connections to the BuildingAutomation System.

l. 3 Nos of Single Pole MCB's Shall be provided at the incoming section of the starter panel forDDC Panel , fire damper actuator & as a spare.

d. Contactor, over load relay with built in single phasing protection.

e. Phase indicating lights and indicating light for ON status.

f. Digital voltmeter and digital ammeter with selector switches.

g. Time delay relay for delayed automatic restart of air handling unit motor.

h. Wiring for microswitch for stopping the fan when fire damper closes.

220 / 24 V Transformer

CONTROL PANEL TYPE -2, PANEL No- 1 IN AIR HANDLING UNIT WITH VFD & HEATING Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

CONTROL PANEL TYPE - 1 FOR AIR HANDLING UNITS ( WITH DOL STARTER )

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, power &control cabling,wiring, incoming, earthing & terminating into MCCB in each panel shall be providedby the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

The number of AHU control panels shall be as follows.

2.5-4.0 Amp MPCB upto 1.5 HP with DOL Starter

2.5-4.0 Amp MPCB 2 HP with DOL Starter

Page 161: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 261

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

The panel shall include the following components and accessories.

b. Phase indicating lights and indicating for ON status.

100 amp 4 pole MCCB type isolator with following accessories.

Incoming

The panel shall include the following components and accessories.

b. Phase indicating lights and indicating for ON status.

100 amp 4 pole MCCB type isolator with following accessories.96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 setPhase indicating light through 2 amps SP MCB -3 sets

Incoming

Bus Bars

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Outgoing150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

CONTROL PANEL TYPE -2, PANEL No- 2 IN AIR HANDLING UNIT WITH VFD , HEATING

a.Suitable rating MPCB with outgoing feeder to 2 HP VFD for AHU.- 1setControl Panel as described above

Page 162: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 2

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Incoming

62

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

Bus Bars

Outgoing

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

a.Suitable rating MPCB with outgoing feeder to 7.5 HP VFD for AHU.- 1set

c.Suitable rating MCB with 1.5 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB ‘s and push button for ON /OFF status of motor - 1 set.

CONTROL PANEL TYPE -2, PANEL No- 3 IN AIR HANDLING UNIT WITH VFD , HEATING COIL& SMOKE EXTRACTION FAN

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

Note : This Panel should be provided with a standby feeder for AHU Fan.

Control Panel as described above

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Page 163: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 163

Phase indicating light through 2 amps SP MCB -3 sets

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoing

a.Suitable rating MPCB with outgoing feeder to 7.5 HP VFD for AHU.- 1set

Bus Bars

c.Suitable rating MCB with 3 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB ‘s and push button for ON /OFF status of motor - 1 set.

CONTROL PANEL TYPE -2, PANEL No- 4 IN AIR HANDLING UNIT WITH VFD , HEATING Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

Note : This Panel should be provided with a standby feeder for AHU Fan.

Control Panel as described above

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

Bus Bars

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoing

Page 164: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 1

Set 265

64 CONTROL PANEL TYPE -2, PANEL No- 5 IN AIR HANDLING UNIT WITH VFD , HEATING COIL & SMOKE EXTRACTION FAN

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

a.Suitable rating MPCB with outgoing feeder to 7.5 HP VFD for AHU.- 1set

Control Panel as described above

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

Bus Bars

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoing

CONTROL PANEL TYPE -2, PANEL No- 6 IN AIR HANDLING UNIT WITH VFD , HEATING COIL & SMOKE EXTRACTION FAN

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

a.Suitable rating MPCB with outgoing feeder to 2 HP VFD for AHU.- 1set

Control Panel as described above

Page 165: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 166

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

a.Suitable rating MPCB with outgoing feeder to 7.5 HP VFD for AHU.-1set

Incoming

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

Bus Bars

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoing

c.Suitable rating MCB with 3 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB ‘s and push button for ON /OFF status of motor - 1 set.

CONTROL PANEL TYPE -2, PANEL No- 7 IN AIR HANDLING UNIT WITH VFD , HEATING COIL & SMOKE EXTRACTION FAN

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

Note : This Panel should be provided with a standby feeder for AHU Fan.

Control Panel as described above

Page 166: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 167

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

Bus Bars

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoing

c.Suitable rating MCB with 2 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB ‘s and push button for ON /OFF status of motor - 1 set.

CONTROL PANEL TYPE -2, PANEL No- 8 IN AIR HANDLING UNIT WITH VFD, HEATING COIL& SMOKE EXTRACTION FAN

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

a.Suitable rating MPCB with outgoing feeder to 10 HP VFD for AHU.- 1set

Note : This Panel should be provided with a standby feeder for AHU Fan.

Control Panel as described above

Page 167: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 168

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.b. Phase indicating lights and indicating for ON status.c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Bus Bars

c.Suitable rating MCB with 3 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB‘s and push button for ON /OFF status of motor - 1 set.

CONTROL PANEL TYPE -2, PANEL No- 9 IN AIR HANDLING UNIT WITH VFD , HEATING COIL & SMOKE EXTRACTION FAN

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a.Suitable rating MPCB with outgoing feeder to 10 HP VFD for AHU.- 1set

Outgoing

Note : This Panel should be provided with a standby feeder for AHU Fan.Control Panel as described above

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

Page 168: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 169

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming100 amp 4 pole MCCB type isolator with following accessories.96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 setPhase indicating light through 2 amps SP MCB -3 setsBus Bars

CONTROL PANEL TYPE -2, PANEL No-10 IN AIR HANDLING UNIT WITH VFD & HEATING COIL

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

a.Suitable rating MPCB with outgoing feeder to 5 HP VFD for AHU.- 1setControl Panel as described above

Outgoing

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Bus Bars

Outgoing

Page 169: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 1

Set 171

70 CONTROL PANEL TYPE -2, PANEL No-11 IN AIR HANDLING UNIT WITH VFD & HEATING COIL

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

a.Suitable rating MPCB with outgoing feeder to 2 HP VFD for AHU.- 1set

Control Panel as described above

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

Bus Bars

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoing

Incoming

CONTROL PANEL TYPE -2, PANEL No-12 IN AIR HANDLING UNIT WITH VFD & HEATING COIL

a.Suitable rating MPCB with outgoing feeder to 5 HP VFD for AHU.- 1set

Control Panel as described above

Page 170: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 172 CONTROL PANEL TYPE -2, PANEL No-13 IN AIR HANDLING UNIT WITH VFD , HEATING

COIL& SMOKE EXTRACTION FAN

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

a.Suitable rating MPCB with outgoing feeder to 2 HP VFD for AHU.- 1set

Outgoing

Bus Bars

Control Panel as described above

Page 171: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 1

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Control Panel as described aboveNote : This Panel should be provided with a standby feeder for AHU Fan.

73

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

CONTROL PANEL TYPE -2, PANEL No-14 IN AIR HANDLING UNIT WITH VFD, HEATING Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

Incoming

c.Suitable rating MCB with 3 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB‘s and push button for ON /OFF status of motor - 1 set

100 amp 4 pole MCCB type isolator with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 sets

Bus Bars

Outgoing150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

a.Suitable rating MPCB with outgoing feeder to 10 HP VFD for AHU.- 1set

Page 172: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 1

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 setPhase indicating light through 2 amps SP MCB -3 setsBus Bars

CONTROL PANEL TYPE -3, PANEL No-1 IN AIR HANDLING UNIT WITH VFD , HEATER Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

Incoming100 amp 4 pole MCCB type isolator with following accessories.

c.Suitable rating MCB with 3 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB‘s and push button for ON /OFF status of motor - 1 set.

Control Panel as described aboveNote : This Panel should be provided with a standby feeder for AHU Fan.

100 amp 4 pole MCCB type isolator with following accessories.96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

74

Phase indicating light through 2 amps SP MCB -3 sets

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

a.Suitable rating MPCB with outgoing feeder to 10 HP VFD for AHU.- 1set

Incoming

Bus Bars

Outgoing

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.Outgoinga.Suitable rating MPCB with outgoing feeder to 30 HP VFD for AHU.- 1set

Page 173: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 1

Set 1

75

Incoming

76

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

CONTROL PANEL TYPE -3, PANEL No-3 IN AIR HANDLING UNIT WITH VFD, HEATING COIL, SMOKE EXTRACTION FAN & HUMIDIFIER

Control Panel as described above

d.Suitable rating MCB with 1.5 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB‘s and push button for ON /OFF status of motor - 1 set

CONTROL PANEL TYPE -3, PANEL No-2 IN AIR HANDLING UNIT WITH VFD , HEATING COIL & HUMIDIFIER

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

c.Suitable rating MCB for humidifier ( 5 litre / hr. approx.)

Control Panel as described above

100 amp 4 pole MCCB type isolator with following accessories.96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 setPhase indicating light through 2 amps SP MCB -3 setsBus Bars150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.Outgoinga.Suitable rating MPCB with outgoing feeder to 20 HP VFD for AHU.- 1setc.Suitable rating MCB for humidifier ( 5 litre / hr. approx.)

Page 174: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

Set 177

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring andearthing terminating into MPCB in each panel shall be provided by the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operationthrough BAS. All starters shall be provided with potential free Contact for Connections to BuildingAutomation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings given below, suitablefor motor duty and able to withstand fault level of 20 KA.

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHUpanel to facilitate override of the automatic operation.

d.Suitable rating MCB with 1.5 HP DOL starter and outgoing feeder to Smoke Extraction fan.Compartment shall contain direct operated digital electronic ammeters of 0-40 amps rang, Auto /Manual selector switch and ON / OFF trip indicating lamp with MCB‘s and push button for ON /OFF status of motor - 1 set

CONTROL PANELS TYPE-4 FOR FANS ( TFA,FAN SECTIONS,VANE & TUBE AXIAL FLOWFANS)

Design, manufacture, supply, installation, testing and commissioning of the following cubicle type,dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiringterminating into MPCB and copper earthing, in each panel shall be provided by the electricalcontractor.

Incoming100 amp 4 pole MCCB type isolator with following accessories.96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 set

Phase indicating light through 2 amps SP MCB -3 setsBus Bars150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoinga.Suitable rating MPCB with outgoing feeder to 20 HP VFD for AHU.- 1setc.Suitable rating MCB for humidifier ( 10 litre / hr. approx.)

Control Panel as described above

Page 175: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

No.21

c. Contactor, over load relay with built in single phasing protection.

d. Phase indicating lights and indicating light for `ON’ status.e. 96 mm x 96 mm voltmeter and ammeter.

f. Time delay relay for delayed automatic restart of motor (0-180 sec).

g. The Control panel shall be out door type and shall have potential free contacts for fire alarmintegration.

h. For on/off/remote and local operation, 3 pole single throw switch shall be provided in eachpanel to facilitate override of the automatic operation.

Rates shall also include the following: All fixing accessories such as brass saddles, brass screws rawl plugs etc.

Cutting chases holes and making good the same wherever required.

Effecting adequate and proper interconnections.

Use of copper thimbles.

Earthing system shall comply to IS: 3043-1987.

The panel shall include the following components & accessories .

a. MCB / MCCB with built-in overload relay and single phase preventor as per the ratings givenbelow, suitable for motor duty and able to withstand fault level of 20 KA.

b. Terminal block for power distribution as required.

The number of control panels shall be as follows.

MPCB with DOL starters suitable for 1-7.5 HP motors

Jointing by riveting and brazing after riveting in case of copper and welding/ bolting in case of GIearthing.

All equipment motors, DB’s, panels to be connected on either ends (double earthing) with suitablestrip/ wires.

CABLES, MAINS AND SUB MAINS

All earthing pits shall be interconnected.

All earthing should be Body earthing to Body Earthing & Neutral earthing to Neutral Earthing.

Page 176: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.)

Amount (Rs.)Description of Items

78

a RM 700

b RM 121

c RM 154

d RM 11

e RM 25

f RM 35

g RM 300

79

aNo. 130

b

No. 130

TOTAL OF SUB HEAD (E)

Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV gradeas required.

4 Core 6 Sq.mm. (Copper armoured Cable)

4 Core 10 Sq.mm. (Copper armoured Cable)

Supplying of following 1100 volt grade XLPE insulated sheathed cable as perspecification in existing trenches, cable trays ducts over bed of sand, clamped includesanchor fastners to wall with suitable clamps, saddles fixing bolts including connectingtesting and commissioning.

4 Core 6 Sq.mm. (Copper armoured Cable)

4 Core 10 Sq.mm. (Copper armoured Cable)

4 Core 16 Sq.mm. (Aluminium armoured Cable)

4 Core 25 Sq.mm. (Aluminium armoured Cable)

3.5 Core 50 Sq.mm. (Aluminium armoured Cable)

3.5 Core 70 Sq.mm. (Aluminium armoured Cable)

3.5 Core 240 Sq.mm. (Aluminium armoured Cable)

END TERMINATION OF CABLES

Page 177: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)

A.

aNo. 4

ANIMAL HOUSE

EQUIPMENT

Supply, installing, testing and commissioning of horizontal FAN COIL UNITS (2 PIPESYSTEMS), blow thru type, each complete with 3 rows deep Chilled Water Coil, one ormore centrifugal fans, cleanable fabric filters, main condensate extended SS drainpans, RA insulated plenum, as described in specifications, casing, coil pipingconnections, through copper pipes, condensate drain connections, wiring, control wiringin conduit upto thermostat boxes. Fan coil unit shall be factory fitted with valvepackage comprising of pressure independent Balancing cum Control Valve withintegrated 2 way motorized actuator in a single body for modulating operation suitablefor static pressure of 1600 kPa and actuator shall be capable of withstanding 400 kPashut off pressure, 24 V AC incoming power supply, ball valve with Y-strainer at inlet &Ball valve at outlet and necessary copper coil piping connections. The actuator ofmodulating valve shall be provided with interface cards to receive 0-10V or 4-20 mAsignal from Digital Thermostat.

The actuator of the valve shall have necessary torque to overcome pressure differentialof 4 bars rating. All fan coil units shall be suitable for 220±6% volts, 50 cycles, singlephase power supply. Fan coil units shall be of following refrigeration capacities aslisted.

1.0 TR nominal capacity - 400 CFM

Double skin TREATED FRESH AIR HANDLING UNITS (in Single /double Deckerconstruction) complete with thermal break profile, Fresh air section with Fresh airmanual AL damper with double HDPE insect mesh, Filter sections with G-4 filters & F6/F9 filters (The Velocity across F6 filters not to exceed 500 FPM), Coil section with CHWcoil & heating coil, PVC Moisture Eliminator,DIDW backward Curved Centrifugal Blower ,Supply air plenum with Supply air manual AL damper, Return Air plenum with return airmanual AL damper, Differential pressure nozzles, Exhaust air manual AL damper withdouble HDPE insect mesh, Magnehelic gauges with pvc tubing across all filters &blower, Service windows as per approved design & Motor for Supply air blower.Thefilter stages shall be as specified in the ahu data sheet.EU 13 filters if specified shall beterminal mounted and rates for the same to be quoted as specified under respectiveitems under filter housing/hooded filters.

Limitswitches in Supply fan section for AHU doors and Inspection lamp, Cushy footmountings, Fire proof double canvass connections (Fungal resistant and Lint free) andStandard accessories duly

Description of Items

80

81

a. 8 Row deep cooling & 2 Row deep heating coil of copper tube and aluminum construction sized at maximum face velocity of 500 fpm.

b. Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supplymeeting criterion as per ASHRAE standard 90.1-2010 and high efficiency.

c. Vibration isolators.

d. Fan outlet velocity not exceeding 10 mps.

Page 178: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

TagNo.

Floor Space Type CFM TR

a AHU- 1 Ground Air Lock-1,2,Change Room,Clean Corridor & Clean Area

FMU 900 7

No. 1b AHU- 2 Ground Mortuary FMU 300 2.5

No. 1c AHU- 3 Ground Dirty Cage wash, Mortuary

Corridor,Dirty Corridor-1 &2 FMU 1300 8

No. 1d AHU- 4 Ground Clean store, Quality Control

Room & Quarantine Room FMU 300 2

No. 1e AHU- 5 Ground

Room-1 FMU 1100 9.4

No. 1f AHU- 6 Ground

Room-2 FMU 1100 9.2

No. 1g AHU- 7 Ground

Room-3 FMU 600 4.7

No. 1h AHU-8 Ground

Room-4 FMU 1100 9

No. 1

Max Motor

Heating

1.5/1 6

1.0/1.0 2

1.5/1.5 8

1.0/1.0 1

1.5/1

e. Minimum 50 mm (WC) external static pressure after sound attenuators. Total static pressure of AHU shall be checked by Vendor.g. VFD designed for HVAC applications for supply air fan with built-in PID controller,control panel (keypad & display) , IP-55 enclosure for use on standard centrifugal fans.The VFDs should not cause any deration of the connected motors and must ensure thatclass B temperature levels of the connected motors are never exceeded. The displayshould be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have builtin harmonic filters.VFD shall be BMScompatible with open protocol communication port, so that complete data can betransported to remote IBMS console.

7.7

1.5/1 8.3

1.0/1.0 3.3

1.5/1 9.2

Note 1 : All to be provided with VFD's. 2 : AHU No- 1, 2,3 & 4 to be provided Exhaust unit with bagin/bag out hepafilter 3 : AHU No- 5, 6,7 & 8 to be provided H-13 hepa at terminal &, 20 micron filter in4 : All AHU to be provided with standby fan arrangement as Animal house are 24

h ti l

Page 179: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

82

No. 1783

a No. 5b No. 1c No. 10

84

a No. 8b No. 485

Tag No.

Floor Space CFM

a IF-1 G d

Toilet 150 No. 1

a No. 8

86

Supply, installation, testing and commissioning of Fan Filter Unit (FFU) of StainlessSteel housing with high performance ,directdriven backward curved fan/ motorcombination with HEPA (99.99 % efficiency ) filter to achive class of air.All selected FFUshall be having 700 CFM flow rate.

Supply, installation, testing and commissioning of Electronic Self Balancing Valvepressure independent with independent type dynamic balancing valve for AHUs withintegrated 2 way modulating control valves in a single body. The actuator shall becapable of accepting 2-10 VDC / 4-20 mA electric signal and shall provide similartransduced feedback output signal to control system for flow measurement. Theminimum close off pressure actuator must be 1.5 times shut off head of pump 5 barswhichever is maximum. The valves shall be suitable for following pipe sizes:

32 mm dia

25 mm dia

20 mm dia

Supply, installation, testing and commissioning of cooling Thermostats for various airhandling units and fan coil units.

Proportional cooling thermostat at AHU.

Proportional cooling thermostat at FCU.

Supplying, installing, testing and commissioning of INLINE FANS suitable for installingin any position in vertical or horizontal ducts. The casing shall be double skin, internallyacoustically lined and constructed of galvanised steel. The fan shall be DIDW withforward curve impeller fitted with maintenance free external rotor motor. The motorshall be suitable for 220±10% volt single phase 50 cycles AC supply. All units shall becomplete with duct flexible connector and volume control damper.

Supplying, installing, testing and commissioning of Pressure Independent Variable AirVolume Terminal units, suitable for installtion in horizontal ducts. The casing shall bedouble skin acoustically lined and constructed with galvanised sheet steel.Shouldinclude all accessories such as single / multileaf damper (with equal % characteristics)etc. actuators, control cabling , thermostat , feed back control cabling upto VFD panel /DDC Panel in AHU room and any other ancilary requirement for the functioning of theunits. Cost of duct mounted Diff. pressure transmitter with cabling upto VFD panel shallalso be included.

VAV boxes shall be suitable for following air flow capacitties.

50 -499CFM

Note : Quoted price shall include the following:

Page 180: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

87

a No. 188

a

No. 3

B.

89

a RM 185b RM 4c RM 9d RM 29e RM 242f RM 22g RM 13090

a No. 291

a No. 1b No. 192

a No. 12

80 mm dia MS pipes

a. Motorized aluminium construction damper with actuator.

b. Differential pressure sensor

PIPING-CHILLED AND CONDENSER WATER

c. 220 volts power supply cord with 6 amp. Plug top up to the power socket

Supply, installation, testing and commissioning of INTEGRATOR for VAV boxes, capableof giving industry standard (Modbus / Lon Works / Bacnet) output to BMS system.Mapping shall be required for monitoring individual room temperature for areasconditioned through VAV boxes. Quoted price shall be inclusive of wiring in GI conduitbetween integrator and individual VAV Boxes.

Integrator as described above for 8 number VAV Boxes.

150 mm dia 1450 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply.

Supplying, installing, testing and commissioning of direct driven PROPELLER FANS forexhaust air as shown in drawings. Each fan shall be complete with permanent splitcapacitor or shaded pole motor, mounting plate, accessories like wire guard, birdscreen and fixed louvers for weather protection as required. Fan selection arrangementand Electrical characteristics shall be as follows :

25 mm dia MS pipes

TOTAL OF SUB HEAD (A)

Providing and fixing in position the following MS class ‘C’ pipes cut to required lengthsand installed with all welded joints, providing and fixing in position the necessaryfittings like elbows, tees and reducers, mating flanges & sockets for BAS:

65 mm dia MS pipes

50 mm dia MS pipes

40 mm dia MS pipes

32 mm dia MS pipes

20 mm dia MS pipes

Providing and fixing in position the following manual butterfly valves (PN 16) :

80 mm dia Valves.

Providing and fixing in position the following manual balancing valves (PN 16) :

80 mm dia Valves.

32 mm dia Valves.

Providing and fixing in position following ball valves (PN 16) :

32 mm dia valves

Page 181: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

b No. 2c No. 20

93

a No. 5b No. 1c No. 106

94 No. 495 No. 196 No. 897

No. 3298

No. 3299

No. 8100

a RM 50

C.101

aSqm 46

102

aNo 8

103

Sqm 1104

Sqm 1.5105

Sqm

32 mm dia valves

20 mm dia valves

25 mm dia Valves.

Supplying, installation, testing and commissioning of Flow Switches .

Providing and fixing in position SS 304 the mercury-in- glass industrial dial typethermometers.

25 mm dia valves

20 mm dia valves

Providing and fixing in position the following ‘Y’ Strainers (PN 16) :

25 mm dia valves

Providing and fixing in position the following Drain Valves :

Supplying, installation, testing and commissioning of Auto air vents(PN-16).

Providing and fixing in position SS 304 the industrial dial type pressure gauges withgun metal valves.

Supply, installation, testing and commissioning of Magnehelic Gauges 100mm dial,range 0 to 60 Pa with SS box, probes & tubes, at different roomsProviding and fixing in position the following GI class ‘B’ pipes cut to required lengthsand installed with all screwed joints, and providing and fixing in position the necessaryelbows, tees and reducers as per specifications for AHU / FCU drain.

25 mm dia GI pipes

TOTAL OF SUB HEAD (B)

AIR DISTRIBUTIONSupply, installation and testing of Factory fabricated GI sheet metal ducts as perSMACNA in accordance with the approved shop drawings and as per specifications.

26 gauge galvanised sheet steel

Supply, installation, testing and commissioning of Aluminum Powder Coated Riserswith filter fixing arrangement & opening complete with perforated grill & bolts in front.

450mm X 150 mm (3.5m Vertical Length)

Supply, fabrication, installation and testing the flexible connections constructed of fireresistant double resin sleeve as per the approved shop drawings.

Supply, installation, testing and balancing of powder coated Extruded Aluminium supplyair Grilles with volume control dampers in accordance with the approved shop drawingsand specifications.

Supply, installation, testing and commissioning of motorised combined smoke & firedamper complete with control panel, inter connecting wiring at locations shown inapproved shop drawings and as per specifications.

Page 182: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

aSqm 2

bNo. 16

106

Sqm 5107

Sqm 10108

Sqm 2.5109

Sqm 3110

Sqm 7111

aNo. 4

D.

112

aSqm 23

113

Smoke & Fire Damper

Control Panel & Wiring(with actuators)

Supply, installation, testing and balancing of Powder coated extruded aluminiumconstruction square / round shape supply air diffusers with removable core & antismudge ring & volume control dampers as per approved drawings and specifications.

Supply, installation, testing and balancing of Powder coated extruded aluminiumconstruction. Square / round shape return air diffusers with removable core,antismudge ring & without volume control damper as per specifications.

Supplying & fixing of opposed blade volume control dampers in supply air duct collarsas per approved drawings and specifications.

Supply, installation, testing and balancing of Powder coated/Anodised extrudedaluminium construction. louvers with bird screen for exhaust air as per specificationsand approved drawings.

Supply, installation, testing and balancing of Powder coated/Anodised extrudedaluminium construction. louvers with bird screen for fresh air as per specifications andapproved drawings.

Hooded Type Terminal Hepa Filter Box with Filter & filter shall be gel seal type &replaceable from Room side, Frame material: Aluminum anodised, Dopefficiency:99.997% down to 0.3 micron with SS Terminal Plate.

Hepa Filter boxes shall be of following sizes.

610 x 610 x 133 (700 CFM)

TOTAL OF SUB HEAD (C)

THERMAL INSULATION

Supply, installation testing and commissioning of acoustic insulation. Material shall beOpen cell Nitrile rubber and all accessories as per specification.

15 mm thick acoustic lining

Supply and installation of External Thermal closed cell crosslinked polyethelene/Nitrilerubber insulation fire rated for Class 0 as per BS 476 Part 6 : 1989 with Self adhesivebacking on ducts as per the approved specifications. Quoted price shall be inclusive ofUV protective coating over exposed to weather ducts.

Page 183: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

aSqm 500

114

aRM 29

bRM 242

cRM 22

dRM 130

eRM 50

115

aRM 185

bRM 4

cRM 9

E.

116

13 mm thick insulation for supply & return air ducts

Supplying, installing and testing of 25 mm thick (pre-moulded pipe section of T.F.quality expanded polystyrene, 24 Kg / M³) insulation on chilled water and condensatedrain piping and fitting like valves, flanges union etc. as per the approved shopdrawings and specifications.

40 mm dia pipes

32 mm dia pipes

25 mm dia pipes

20 mm dia pipes

25 mm dia condensate drain pipes.

Supplying, installing and testing of 50 mm thick (pre-moulded pipe section of T.F.quality expanded polystyrene, 24 Kg / M3) insulation on chilled water piping and fittinglike valves, flanges union, etc. as per the approved shop drawings and specifications.

80 mm dia pipes

65 mm dia pipes

50 mm dia pipes

TOTAL OF SUB HEAD (D)

ELECTRICAL INSTALLATION

CONTROL PANEL PANEL No-1 to 8 IN AIR HANDLING UNIT WITH VFD

Design, manufacture, supply, installation, testing and commissioning of the followingcubicle type, dead front, sheet steel, wall mounted control panels including anchoringinto the wall, wiring and earthing terminating into MPCB in each panel shall be providedby the electrical contractor.

All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitateoperation through BAS. All starters shall be provided with potential free Contact forConnections to Building Automation System.

The panel shall include the following components and accessories.

a. MCCB with over-load relay and single phase preventer as per the ratings givenbelow, suitable for motor duty and able to withstand fault level of 20 KA.

Page 184: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

Set 8

117

aRM 150

b. Phase indicating lights and indicating for ON status.

c. For on/off/remote and local operation, 3 pole single throw switch shall be provided ineach AHU panel to facilitate override of the automatic operation.

Incoming

32 amp 4 pole MCB with following accessories.

96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set

0-32 amps digital electronic ammeter with selector switch and 100/5 amps 5VA,CL.1CTs – 1 setPhase indicating light through 2 amps SP MCB -3 Set

Bus Bars

150 amps 4 pole copper bus bars with heat shrinkable insulation sleeve.

Outgoing

a. 16 Amp MCB with outgoing feeder to 1.5/1.0 HP VFD for AHU.- 1set

b.16 Amp MCB with outgoing feeder to 1.5/1.0 HP DOL for AHU.- 1set

Control Panel as described above

CABLES, MAINS AND SUB MAINS

Supplying of following 1100 volt grade XLPE insulated sheathed cable as perspecification in existing trenches, cable trays ducts over bed of sand, clamped includesanchor fastners to wall with suitable clamps, saddles fixing bolts including connectingtesting and commissioning.

4 Core 2.5 Sq.mm. (Copper armoured Cable)

Rates shall also include the following:

Providing and fixing junction boxes with covers including painting.

Effecting adequate and proper connections at terminations.

Providing all fixing accessories such as clamping devices nuts, bolts and screws.

Excavation laying of cable filling of sand, brick protection, back filling of earth,watering, ramming and making good.Earthing system shall comply to IS: 3043-1987.

All cable shall be laid with one diameter gap.

Page 185: PART 2 FINANCIAL BID SCHEDULE (BILL) OF  · PDF fileFINANCIAL BID SCHEDULE (BILL) OF QUANTITIES. Sch. No. PARTICULARS Estimated Cost (In Rs.) Quoted % above/below in Figures

Item No. Unit Qty.

Rate in figures (Rs.)

Rate in words (Rs.) Amount (Rs.)Description of Items

118

a No. 16TOTAL OF SUB HEAD (E)

Total cost of NON Schedule items (HVAC WORK)-Laboratory+AnimalSCHEDULE-F

Fire retardant paint one meter on both side of wall penetration and at termination asper specifications.Buried LT cables to be laid atleast 750 mm below ground.

All cut-outs/ Sleeves shall be sealed with fire retardant sealant as per specification.

END TERMINATION OF CABLES

All cables shall be IS approved.

Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductorcable of 1.1 KV grade as required.