12
U.S.A. Yorkville Sound Inc. 4625 Witmer Industrial Estate Niagara Falls, New York 14305 USA Voice: (716) 297-2920 Fax: (716) 297-3689 WORLD HEADQUARTERS WEB ACCESS: http://www.yorkville.com CANADA Yorkville Sound 550 Granite Court Pickering, Ontario L1W-3Y8 CANADA Voice: (905) 837-8481 Fax: (905) 837-8746 Quality and Innovation Since 1963 Printed in Canada SERVICE MANUAL PSA1s MODEL TYPE: YS1099

Paraline Sm Psa1s

Embed Size (px)

Citation preview

Page 1: Paraline Sm Psa1s

U.S.A.

Yorkville Sound Inc. 4625 Witmer Industrial Estate

Niagara Falls, New York 14305 USA

Voice: (716) 297-2920 Fax: (716) 297-3689

WORLD HEADQUARTERS

WEB ACCESS: http://www.yorkville.com

CANADA

Yorkville Sound 550 Granite Court Pickering, Ontario

L1W-3Y8 CANADA

Voice: (905) 837-8481 Fax: (905) 837-8746

Quality and Innovation Since 1963Printed in Canada

SERVICE MANUAL

PSA1sMODEL TYPE: YS1099

James
Typewritten Text
Manual-Service-PSA1S-00-1v1.pdf
Page 2: Paraline Sm Psa1s

The exclamation point within an equilatereal triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

Le point d’exclamation à l’intérieur d’un triangle équilatéral est prévu pour alerter l’utilisateur de la présence d’instructions importantes dans la littérature accompag-nant l’appareil en ce qui concerne l’opération et la maintenance de cet appareil.

This lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient

magnitude to constitute a risk of electric shock to persons.

Ce symbole d’éclair avec tête de flèche dans un triangle équilatéral est prévu pour alerter l’utilisateur de la présence d’un « voltage dangereux » non-isolé à proximité de l’enceinte du produit qui pourrait être d’ampleur suffisante pour présenter un risque de choque électrique.

IMPORTANT SAFETY INSTRUCTIONS

safety-4v8 • April 14/2011

CAUTION: TO REDUCE THE RISK OF ELECTRICSHOCK, DO NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

THIS DEVICE IS FOR INDOOR USE ONLY!

FOLLOW ALL INSTRUCTIONS SUIVEZ TOUTES LES INSTRUCTIONSInstructions pertaining to a risk of fire,

electric shock, or injury to a person

Read Instructions: The Owner’s Manual should be read and understood before operation of your unit. Please, save these instructions for future reference and heed all warnings.

Clean only with dry cloth.

Packaging: Keep the box and packaging materials, in case the unit needs to be returned for service.

Warning: To reduce the risk or fire or electric shock, do not expose this apparatus to rain or moisture. Do not use this apparatus near water!

Warning: When using electric products, basic precautions should always be followed, including the following:

Power SourcesYour unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the unit. This unit has a polarized plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted. Precau-tions should be taken so that the grounding scheme on the unit is not defeated. An apparatus with CLASS I construction shall be connected to a Mains socket outlet with a protective earthing ground. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

HazardsDo not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the manufacturer or sold with the product. Follow the manufacturer’s instructions when installing the product and use mounting accessories recommended by the manufacturer. Only use attachments/accessories specified by the manufacturer

Note: Prolonged use of headphones at a high volume may cause health damage on your ears.

The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be placed on the apparatus.

Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals require installation by an instructed person or the use of ready made leads or cords.

Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

No naked flame sources, such as lighted candles, should be placed on the apparatus.

Power CordDo not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on or pinched particularly at plugs. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power supply cord shall remain readily operable.

Unplug this apparatus during lightning storms or when unused for long periods of time.

ServiceThe unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

AVIS: AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE,N’ENLEVEZ PAS LE COUVERT (OU LE PANNEAU ARRIERE)

NE CONTIENT AUCUNE PIECE REPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN QUALIFIE POUR L’ENTRETIENT

CE PRODUIT EST POUR L’USAGE À L’INTÉREUR SEULEMENT

Instructions relatives au risque de feu,choc électrique, ou blessures aux personnes

Veuillez Lire le Manuel: Il contient des informations qui devraient êtres comprises avant l’opération de votre appareil. Conservez. Gardez S.V.P. ces instructions pour consultations ultérieures et observez tous les avertissements.

Nettoyez seulement avec le tissu sec.

Emballage: Conservez la boite au cas ou l’appareil devait être retourner pour réparation.

Avertissement: Pour réduire le risque de feu ou la décharge électrique, n'exposez pas cet appareil à la pluie ou à l'humidité. N’utilisez pas cet appareil près de l’eau!

Attention: Lors de l’utilisation de produits électrique, assurez-vous d’adhérer à des précautions de bases incluant celle qui suivent:

AlimentationL’appareil ne doit être branché qu’à une source d’alimentation correspondant au voltage spécifié dans le manuel ou tel qu’indiqué sur l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. Ne pas utiliser cet appareil avec un cordon de raccordement à moins qu’il soit possible d’insérer complètement les trois lames. Des précautions doivent êtres prises afin d’eviter que le système de mise à la terre de l’appareil ne soit désengagé. Un appareil construit selon les normes de CLASS I devrait être raccordé à une prise murale d’alimentation avec connexion intacte de mise à la masse. Lorsqu’une prise de branchement ou un coupleur d'appareils est utilisée comme dispositif de débranchement, ce dispositif de débranchement devra demeurer pleinement fonctionnel avec raccordement à la masse.

RisqueNe pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table recommandés par le fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer l’appareil et utiliser les accessoires recommandés par le fabricant. Utilisez seulement les attachements/accessoires indiqués par le fabricant

Note: L'utilisation prolongée des écouteurs à un volume élevé peut avoir des conséquences néfastes sur la santé sur vos oreilles. .

Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées.

L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et qu’aucun objet rempli de liquide tel que des vases ne doit être placé sur l’appareil.

Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à l’installation près de source de chaleur tels que radiateurs, registre de chaleur, fours ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.

Les dispositifs marqués d’une symbole “d’éclair” sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en utilisant des cordons déjà préparés.

Cordon d’AlimentationNe pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de mise à la masse du cordon d’alimentation. Une prise polarisée dispose de deux lames dont une plus large que l’autre. Une prise avec tige de mise à la masse dispose de deux lames en plus d’une troisième tige qui connecte à la masse. La lame plus large ou la tige de mise à la masse est prévu pour votre sécurité. La prise murale est désuète si elle n’est pas conçue pour accepter ce type de prise avec dispositif de sécurité. Dans ce cas, contactez un électricien pour faire remplacer la prise murale. Évitez d’endommager le cordon d’alimentation. Protégez le cordon d’alimentation. Assurez-vous qu’on ne marche pas dessus et qu’on ne le pince pas en particulier aux prises. N’UTILISEZ PAS L’APPAREIL si le cordon d’alimentation est endommagé. Pour débrancher complètement cet appareil de l’alimentation CA principale, déconnectez le cordon d’alimentation de la prise d’alimentation murale. Le cordon d’alimentation du bloc d’alimentation de l’appareil doit demeurer pleinement fonctionnel.

Débranchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.

ServiceConsultez un technicien qualifié pour l’entretien de votre appareil. L'entretien est nécessaire quand l'appareil a été endommagé de quelque façon que se soit. Par exemple si le cordon d’alimentation ou la prise du cordon sont endommagés, si il y a eu du liquide qui a été renversé à l’intérieur ou des objets sont tombés dans l'appareil, si l'appareil a été exposé à la pluie ou à l'humidité, si il ne fonctionne pas normalement, ou a été échappé.

S2125A

Page 3: Paraline Sm Psa1s

PART# DESCRIPTION1 3522 DPDT MINI PC VERT SNP ALT

Line/Speaker Mode Switch2 4010 XLR FEML PCB MT VERT 24MM AA-SERIE

Input Jack3 4063 1/4IN ISO JCK PCMT VT STER RT SWT

Input and Link Jack4 4135 XLR MALE PCB MT VERT 24MM BA-SERIE

Link Jack5 4434 10K B LIN 9MM DETENT

Level Control6 6400 YEL 3MM LED 1V9 6MA HIGH EFF

Limit L.E.D.7 6405 RED 3MM LED 2V0 20MA BRT

Clip L.E.D.8 6408 GRN 3MM LED 1V9 5MA FROSTED

Power and Protect L.E.D.9 3587 DPDT ROKR SW QUIK 250"AC/PWR ON-OF

Power Switch10 3606 12.00 AMP CIRCUIT BREAKER11 4088 IEC POWER V-LOCK INLET

A.C. in12 8637 ROUND PUSH BUTTON 1/4" BLK 24MM

Line/Speaker Mode Switch Knob13 8653 LS701-801-2100 POINTER AT 12 KNOB

Level Knob14 3074 POWER CORD 3M V-LOCK (N.A)15 7517 12" 4R 600WPGM SPKR16 9170 STAND ADAPTER CAST17 8529 RUBBER FOOT 65 X 20MM

On side to secure stacking18 8545 RECESSED RUBBER BUMPER WITH WASHER19 8565 BAR HANDLE ALL METAL RECTANGULAR20 9970 RIGID CASTER

SERVICE-QuickGuide-PSA1S 1.00.xls April 23, 2012

PSA1S Quick Guide

7 6

8

2 1 41 12

35 313

11 910

1519

16

19

18

20

Page 4: Paraline Sm Psa1s

SpecificationsActive or Passive Active

Program Power (watts) 1400 Watts Program (2800 Watts Peak)Max SPL (dB) 135dB Peak (129dB Continuous)

Frequency Response (Hz +/- 3db) 37Hz-100HzCrossover Frequency (Hz) fixed @ 100Hz

Driver Configuration 2x12-inch (Bass Reflex Cabinet)LF Driver(s) 2x12-inch Ceramic with 3-inch VoiceCoil

LF Impedance (ohms) 2x4 Ohm LoadLF Power Amplifier (watts) Class D

Power Consumption (typ/max) 210VA / 440 VAEnclosure Materials 15mm Birch

Baffle Material 15mm BirchCovering / Finish Paint

Dimensions (DWH xbackW, inches) 22.75 x14 x 32Dimensions (DWH xbackW, cm) 57.8 x 35.6 x 81.3

Weight (lbs/kg) 120 / 54.6* Specifications subject to change without notice

Page 5: Paraline Sm Psa1s

LIMITER

POWERSUPPLY

CLASS-D POWER PHYSICS

A-1214

SLOW DETECT

FAST DETECT

LOWPASS LOWPASS

LEVEL

13

2

23

1

LINE / SPKR

CLASS-D POWER PHYSICS

A-1214

BLOCK-DIAG-PSA1S-00-1v0

REF IN

BUFFERS

WOOFER

WOOFER

MODEL TYPE:YS1099

EQ HP HP

LIMITERLED RMS

CLIP DETECTCIRCUIT

Block Diagram for PSA1sD E S I G N E D & M A N U FA C T U R E D B Y Y O R K V I L L E S O U N D

Page 6: Paraline Sm Psa1s

11 11

10 10

9 9

8 8

7 7

6 6

5 5

4 4

3 3

2 2

1 1

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

J

J

K

K

L

L

M

M

N

N

O

O

P

P

Q

Q

of

Filename:

PCB# Sheet 31

Product

Date: Rev: YsType: YSLM1449V02SCH.sch2006

M1449Tue Jul 17, 2012

PreampV02

PSA1s

1/4W 150K

R37

.

1/4W 27K

R64

.

1/4W 15K

R77

.

4148D22

1/4W 68K

R17

.

R191/4W

.27K

P1:B

R161/4W

.27K

4148D11

X1

C763V100NRAD .2in

TO92

MPSA06

Q35103

Use YS#4007

LD3YEL 6400

Limit

(VCC)

LM13600N

Dual VCA6745U4:C

{Function}

R361/4W

MINI20K0

R471/4W

.4K7

Q25108

2N5401

TO92

1/4W249R

R29

.

U6:A

TL072

C17100V15P

1/4W 113K

R1

.

50VC2

470P

R21.0W

0.5%9K76

50VC1

470P

R451/4W

.220K

C1963V470N

1/4W 10K0

R39

MINI

1/4W 681R0

R81

0.1%

4148D2

4148D8

1/4W 681R0

R80

0.1%

4148D1

4148D7

4148

D15

1N5242B ZD1

0W512V0

1/4W 249R

R32

.1/4W249R

R31

. 63VC34

100N

R631/4W

.68K

C2150V 22U

63VC35

100N

100VC11

39N

63VC30

100N

R71/4W

0.1%9K76

R61/4W

0.1%9K76

C29100V100P

R421/4W

MINI10K0

1/4W 470R

R23

.

R101/4W

.4K7

1/4W 31K6

R79

.

TO92

2N5551

Q55107

4148D24

R571/4W

MINI20K0 4148

D10

4148

D12

C1063V100NRAD .2in

1/4W 820R

R24

.

R251/4W

.24K

1/4W 49K9

R75

.

R561/4W

MINI20K0

12dB HP @ 40Hz

C563V150N

R541/4W

.10K

R731/4W

.24K

U3:A

TL074CN

1/4W 220K

R11

.

R121/4W

.2K2

R141/4W

.10K

C2750V470P

4148D4

C1563V100NRAD .2in

C963V100NRAD .2in

R281/4W

.1K5

LD1RED 6405

Clip

R921/4W

.619R

R911/4W

.619R

R181/4W

.24K

1/4W 10K0

R90

MINI

1/4W 10K0

R89

MINI

1/4W 1K5

R51

.

(VCC)

LM13600N

Dual VCA6745U4:D

{Function}

RIN

G

J3

Input

RIN

G

J4

Link

U4:

E

18uH3899

L2

R331/4W

.31K6

R31.0W

0.5%9K76

1/4W 22M

R52

.

4148

D19

G/Y18AWG

W6

GND

R431/4W

.2K43

8V

+4

V-

U8:C

C3100V100P

U1:A

TL074CN

4V

+11

V-

U1:E

R411/4W

MINI20K0

4V

+11

V-

U5:E

1/4W 49K9

R76

.

1/4W 49K9

R74

.

R531/4W

.2K2

U5:D

MC33079P

4V

+11

V-

U3:E

1/4W 10K

R71

.

1/4W 22K

R26

.

100VC6

39N

4148D3

4148D17

25VC40

100U

25VC42

100U

R931/4W

.619R

63VC33

100N

63VC32

100N

R881/4W

.619R

4148D18

25VC41

100U

Rail-Tracking Peak Limiter

1 2 W4:A

R211/4W

.27K

C16100V15P

Full-Wave Rectifier

12dB LP @ 95Hz

4148D5

13 14 W2:M

11 14 W2:K

8 14 W2:H9 14 W2:I

6 14 W2:F

4 14 W2:D

1 14 W2:A

14 14 W1:N

12 14 W1:L

9 14 W1:I

7 14 W1:G

5 14 W1:E

4 14 W1:D

214W1:B

Amp Headers

1/4W 49K9

R49

.

R611/4W

.4K7

4148

D13

V+ FromPower Supply

2 2 W4:B

1/4W 21K5

R59

.R461/4W

.470K

C1863V470N

4148D14

1/4W 249R

R30

.

1N5242B ZD2

0W512V0

1/4W 10K0

R40

MINI

1/4W 150K

R38

.

R351/4W

MINI20K0

U6:B

TL072

R341/4W

.31K6

UP

Alte

rnat

e

DOWN Line/SpeakerS1:B3522

1/4W113K

R5

.

R91/4W

0.1%17K40

4010

J5

Input

R81/4W

0.1%17K40

U1:C

TL074CN

R621/4W

.10K

TO92

2N5551

Q45107

C2050V 22U

1/4W 15K

R78

.

U3:C

TL074CN

U3:D

TL074CN

R201/4W

.24K

C1363V100NRAD .2in

C1263V100NRAD .2in

63VC31

100N

C463V220N

R131/4W

.10K

1/4W 10K

R55

.

C1450V470P

M

4459P1:A 10K

B

Level

10 14 W2:J

12 14 W2:L

14 14 W2:N

7 14 W2:G

214W2:B314W2:C

5 14 W2:E

13 14 W1:M

10 14 W1:J11 14 W1:K

314W1:C

6 14 W1:F

8 14 W1:H

1 14 W1:A

12dB LP @ 95Hz

U2:A

MC33079P

R151/4W

.27K

C863V100NRAD .2in

Use YS#4007

Clip @ approx 12.7VpkTO92

MPSA13

Q15105

R271/4W

.150K

R871/4W

MINI10K0

U5:B

MC33079P

12dB HP @ 40Hz

1/4W 21K5

R60

.

1/4W 10K

R48

.

1/4W 6K04

R44

.

LM13600NU4:A

LM13600NU4:B

U8:A

TL072

UP

Alte

rnat

e

DOWN Line/SpeakerS1:A3522

1/4W113K

R4

.

265V48R

R98

6543

U1:B

TL074CN

R581/4W

MINI20K0

4148D23

1/4W 68K

R22

.

U5:C

MC33079P

U1:D

TL074CN

1/4W 10K

R72

.

U2:C

MC33079P

4V

+11

V-

U2:E

U5:A

MC33079P

R861/4W

MINI4K99

U2:D

MC33079P

8V

+4

V-

U6:C

Power Limiter

U2:B

MC33079P

Boost 3.5dB @ 40Hz

U8:B

TL072 U3:B

TL074CN

4135

J2

Page 7: Paraline Sm Psa1s

11 11

10 10

9 9

8 8

7 7

6 6

5 5

4 4

3 3

2 2

1 1

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

J

J

K

K

L

L

M

M

N

N

O

O

P

P

Q

Q

of

Filename:

PCB# Sheet 32

Product

Date: Rev: YsType: YSLM1449V02SCH.sch2006

M1449Tue Jul 17, 2012

MCU/Power SupplyV02

PSA1s

BRN

4007

D20

4007

D214007

D9

4007

D16

S2

Use YS#4007

3 3 W9:C

WHT

YEL/BLK

56W3:E

GRY

YEL

GRY

VIO

RED

C5150V470P

8 9 W11:H

6 9 W11:F

4 9 W11:D

2 9 W11:B

Circuit Breaker

C26275V

1u0

22

AC In

W16:B

1/4W 470R

R50

.

C50250V

4N7

W100

4127

K1:A

NTC5R0

R100

6489

240Vac

2 2 W8:B

1 2 W8:A

120Vac

2 2 W7:B

BLU

BLK

K1:B

4127

46W3:D

66W3:F

SECONDARIES

1/4W 820R

R102

.

1/4W 113K

R95

.

TO92

2N5551

Q65107

56W5:E

46W5:D

36W5:C

26W5:B

16W5:A

63

42

15 40

97

R1031/4W

.15K

R961/4W

MINI10K0

4148

D26

F42486

T1.5

F32486

T1.5

4148D25

18X35MM

3300UC37

50V

18X35MM

3300UC36

50V

160VC22:A

4700U

R851/4W

MINI10K0

IN

REF

OUTMC7915CT

TO2206871

U10

IN

REF

OUTMC7815CT

TO2206872

U9

160VC25:A

4700U

160VC24:A

4700U

W120

+120V

R831/4W

MINI10K0

R821/4W

MINI10K0

63VC45

100N

INREF

OUT

MC7905CT

6736

U12

IN

REF

OUTMC7805CT

TO2206738

U11

To LimiterW15:B2

W15:A2

63VC47

100N

2.0W 5K1

R99

.

2.0W 5K1

R97

.

7 9 W11:G

9 9 W11:I

3 9 W11:C

1 9 W11:A

5 9 W11:E

IEC

_RE

CT

C28250V

4N7

C4363V

100N

2 3 W9:B

1 3 W9:A

1 2 W7:A

4148

D29

66W5:F

8V

+4

V-

U13:C

R841/4W

MINI10K0

5V15124

ZD65

1N5338B

5W0

5%

ZD675V1 5W01N5338B5%

5124

Use YS#3606 breaker for both NA and CE.

Pin 6 N.C.

BAT85

D28

2 6 W3:B

BDM_PORTTHESE PARTS ARE NOT STUFFED.

1500UH

L13817

12W16:A

2 1

4093

PRIMARIES

RAD .2in

100UC53

25V

TO92

BC560C

Q75102R101

1/4W.

180R

RAD .2in

22UC52

50V

BAT85

D27

1 6 W3:A

3 6 W3:C

63VC39

100N

63VC38

100N

63VC46

100N

63VC44

100N

160VC23:A

4700UBRIDGE

D6SIP

6772

U13:A

TL072

S15

DPDT Switch

LD2GRN 6408

Power/Fault

3

VDD

4

VSS

6 PTA21PTA5

7 PTA1 2BKGD

5 PTA3

8 PTA0U7

6971

3 2 13575

CH1415U

1/4W 10K0

R94

MINI

Open Woofer Shutdown

Microcontroller (on preamp board)

U13:B

TL072

Page 8: Paraline Sm Psa1s

11 11

10 10

9 9

8 8

7 7

6 6

5 5

4 4

3 3

2 2

1 1

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

I

I

J

J

K

K

L

L

M

M

N

N

O

O

P

P

Q

Q

of

Filename:

PCB# Sheet 33

Product

Date: Rev: YsType: YSLM1449V02SCH.sch2006

M1449Tue Jul 17, 2012

ECOV02

PSA1s

W5:GBUT1

EC100EC27

EC12EC11

RTVEC36EC10

52025x3

C22:D

41924x3

C22:C

31823x3

C22:B

EC107EC106 EC113

EC55 EC54EC53

EC61 EC51EC50

41924x3

C24:C

52025x3

C24:D

31823x3

C24:B

EC115XC35

EC56 EC58

EC65EC59

1 BEC1 EC26

EC31EC24

EC67EC64 EC63

EC70EC35

EC69EC68

EC73EC72

B CTO-92

MPSA63

MPSA43

2N5551

E

MPSA56

MPSA06MPSA13

2N5401

R66

WIR22AWG SOLID

LEAD/PIN REFERENCE

W9:D

EC103 EC114

EC57EC52 EC14 W16:C

EC66EC62EC60EC37

52025x3

C23:D

41924x3

C23:C 41924x3

C25:C

52025x3

C25:D

31823x3

C23:B 31823x3

C25:B

R68

WIR22AWG SOLID

EC71

"STYLE_P32"

6882_PC

6745_PC 6804_PC

Documentation/Process

12

9

6

3

13

1011

7

4

12

5

8

V

V

V

V

V

VV

V

V

V

V

V

V

D

D

D

D

N

N

N

N

D

DD

D

D

D

D

D

D

N

NN

N

N

N

N

N

N

13

10

7

4

1

9

1112

8

#

23

56

VER#MODEL(S):-

DATE DESCRIPTION OF CHANGE

V

V01

VD

03-JUN-2011

N

N

PSA1s

D N

M1449 PCB HISTORY

PC8329 - MARKED 'WOOFER SHUTDOWN' CIRCUIT PARTS AS DNS. - ML

V01.

28-NOV-2011.

V02Changed R65/R67 from YS#6459 to YS#5124. - MLRenamed R65/R67 to ZD65/ZD67. - MLChanged R39/R40 from YS#6123 to YS#6116. - MLPC8313 - C44 moved away from U9. - ML

PC8358 - YS#4100 XLR changed to YS#4135. - ML19-DEC-2011

Force updated large PSU caps with slots. - MLPC8447 - Changed C43 from 5216 to 5212. - ML07-MAY-2012 .

.

.

.

.

...

.

.

.

.12-JUL-2012 PC8458 - Changed pot 4434 to 4459. - ML

REF KNOBPART#MODEL(S):-

FUNCTION

RR

RRR

RRR

RRR

P1

FF

FFF

FFF

FFF

Level

KK

KKK

KKK

KKK

8653

PP

PPP

PPP

PPP

4432

NN

NNN

NNN

NNN

{NEW}N

M1449 PotlistPSA1s

6

3

#

45

12

VER#DATEMODEL(S):-

DESCRIPTION OF CHANGE

V

V

VV

VV

D

D

N

N

DD

DD

NN

NN

M1449.PCB_DATABASE_HISTORYPSA1s

Mounting/Assembly

12

9

6

3

13

1011

7

4

12

5

8

V

V

V

V

V

VV

V

V

V

V

V

V

D

D

D

D

N

N

N

N

D

DD

D

D

D

D

D

D

N

NN

N

N

N

N

N

N

6

3

5

2

4

1# PENDING CHANGEPC#MODEL(S):-

*PLACE IMPLEMENTED CHANGES INTO BOARD HISTORYPC

PC

PC

PC

PC

PC

X

X

X

X

X

X

M1449 PENDING CHANGESPSA1s

Page 9: Paraline Sm Psa1s

M1449

VCDORIGIN

CLINCHINSERT

ORIGIN

.175

.225

.475

.475

SEE NOTE 7

2ozCopper

Step

And

Rep

eat -

X1@

1.23

4Y2@

4.60

0

BlankSize - 14500x10200ADD RTV BETWEENTHESE CAPS.

ADD RTV BETWEENTHESE CAPS.

SEE LAYOUT DOCUMENTATION PSA1S

VTR

VTR

VTR

VTR

RTV

12

VTR VTR

VTR

VTR VTR VTR 1 2

NO

L

NC

L

NO

R

NC

R

CL

CR

13

2

45

6

21

1413

21

1413

VTR

VTR

RTV

TIP

RIN

G-S

W

TIP-SW

SLEEVE

RING

VTR

300

300

NO

VTR

21

3

TIP

RING-SW

TIP

-SW

SLEEVE

RIN

G

5R0

300

300

+ -AC AC

300

CLI

P

LIM

IT

+V SENSE

LIN

E/SP

EAKE

R

AMP A

AMP B

LEVE

LLI

NK

POW

ER/F

AULT

INPU

T

LIN

K

6543

5124

6405 6400

2355

2354

2345

6738

8829

2355

4056

3522

2355

4166

2359

2359

6451

6451

2355

6872

2355

4067

4459

4063

2345

2355

4162 4162

6736

6408

4010

4063

4135

3817

6489

5262

58575857

4162

4146 6871

58575857

5124

6772

4147

31K6

15P

31K6

4148

27K

68K

100N

49K9

2N55

5110

0N

470N

4148

24K

12V0

619R

619R

619R61

9R

820R

4007

681R

0

150K

10K

10K

68K

31K6

10K

10K

470N

220K

24K

5K1

2.0W

1K5

470R

PTC

22M249R

249R

15P

10K

470P24K

100N

100N

9K769K76

4K7

4148

10K0

10K010K0

180R

100N

4007 5V1

RED

YEL

150K

BUTT

ON

9K761.0W

470P

113K

9K761.0W

27K

10K0

150K

100N

100N

10K

10K0

2N5401

100N

220N

4148

100N

100N

4K7

10K

27K

100P

100P

6K04

49K9

49K9

TL07

2

20K0

4148

TL074CN

39N

100N

WHT

12V0

100N

WH

T

25V

100U

4148

BC560C 25V100U

100N

TO22

0

MC

7805

CT

4007

WHT

100N

100N

4148

113K

470P

681R

0

22K

WH

T

4148

470P

MP

SA

06

100N

15K

150N

2K2

24K

2K2

220K

4148

27K

2K43

68K

470K

WHT

21K5

25V100U

4N7

250V

4N7

250V

WHT

5K1

2.0W

100N

TO22

0

MC

7815

CT

WHT

3300

U50

V

100N

49K9MPSA13

41484148

41481K5

249R

27K

113K414820K0100N

20K0

4148820R

41484148

17K40

10K04K994148

15K

T1.5

249R 10K

4K74148

20K0

2N5551

22U50V

22U50V

20K0

TL07

2

15K

4148

39N

MC33079P

B10

K

470R

17K40

4148

WHT

WHT

25V

100U

RELAY 1A

4007

TO22

0

MC

7905

CT

T1.5

18uH

GR

N 100N

LM13600N

TL074CN

1500

UH

275V1u0

21K5

4700U

160V

4700U

160V

MC

9S08

QD

2

Yellow

TO22

0

MC

7915

CT

3300

U50

V

4700U

160V

4700U

160V

5V1

20K0

BRIDGE Body

MC33079P

V02

M14

49

V02

1/2

2/2M1449

PSA

1S

PSA1S

M1449 V02

R33

C17

R34

D24

R21

R63

C12

R76

Q4

C10

C19

D19

R73

ZD1

R92R91

R88R

93

R10

2

D9

R80

R38

R14 R13

R17

R79

R72

R71

C18

R45

R20

R99

R28

R50

R98

R52R29

R31

C16

R55

C14R25

C31

C30

R7R6

R47

D23

R42

R87R89 R101

R66

C46

D21

R68

ZD67

LD1

LD3

R27

R2

C1

R4

R3

R16

R40

R37

C34

C35

R62

R39

Q2

C9

C4

D18C33

C32

R10

R54

R19

C29

C3

R44

R75

R74

U8

R58

D12

U3

C11

C13

ZD2 W4

C43

C41 D29 Q7C53

C44

U11

D20

W15

C39

C47

D4

R5

C2

R81

R26

S1

D11

C27

Q3

C8

R77

C5

R12

R18

R53

R11

D22

R64

R43

R22

R46

BEC

LOC

R60

1

W3

1

W1

1W2

C42

C28

C50

R97

C38 U9

1W

11C

37

C45

R49Q1

D15

D14

D13

R51

R32

R15

R1

D10

R57C7

R56

D5R24

D1D7

R9

R90R86D2 R103

F4

R30 R48R

61D3

R36

Q5

C21C20

R35

U6

R78

D17

C6

U2P1

J4

R23

R8

W6 G/Y

D8

21W7

120V

1 2W8

240V

C40K1

D16

U12

F3

L2

LD2

J5

J3

C15

J2

U4

U1

L1

R100

C26

R59

C23C22

U7

12

W16A

C IN

13

W9

XFM

R P

RIM

AR

Y

U10

C36

C25C24

ZD65

R41

D6

U5

61

W5

XFM

R S

ECO

ND

AR

Y

Page 10: Paraline Sm Psa1s

V02M1449SEE LAYOUT DIAGRAM

PRODUCTION NOTES

6. Place U10 and U12 aligned on the SIL pad. No shorts to the heatsink are allowed.

1. RTV must be applied to the following caps: C22,C23,C24,C25,C26,C28,C36,C37,C50.2. Apply RTV between C22 and C23 as well as between C24 and C25.3. RTV must be applied to inductor L1.

7. Mount the TO-220 retaining spring as per the diagram below: NOTE: NUT IS ON TOP!

4. PC8292 for V01 boards only:Replaced R66 and R68 with #4599 jumpersReplaced R65 and R67 with #6459 4V7 zener diodes.Replaced R27 with #4839 150K 1/4W resistor.5. Apply RTV between C53 and R102 and bend C53 over R102 as in picture.

Outer heatsink

TO220 parts

8841

8581

PCB8833 screw

Inner heatsink4022 - Sil pad

3977 - Yellow spring

Mike
Line
Mike
Line
Page 11: Paraline Sm Psa1s

TL072 TL074MC33079 LM13600

LEAD/PIN REFERENCE

SEE LAYOUT DIAGRAM

E CBTO 92

MPSA43

MPSA06

2N5401

MPSA56

MPSA13

MPSA63

2N5551

"STYLE_P32"

4

2

-V

A

5

7

3

1

B

+V

6

8

16 14 12 10

1 3 5 7

V-

91315 11

2 4 6 8

6

4

2

+V

1

-V

4

9

11

13

7

5

3

1

2 3

8

10

12

14

FUNCTION KNOBREFMODEL(S):-

PART#

RRR

RRR

RRR

P1RR

FFF

FFF

FFF

LevelFF

PPP

PPP

PPP

4432PP

NNN

NNN

NNN

NNN

KKK

KKK

KKK

8653KK

{NEW}

M1449 PotlistPSA1s

11

8

5

2

12

9

6

13

10

7

34

1

D

D

D

D

V

V

V

V

N

N

N

N

D

D

D

D

D

D

DD

D

V

V

V

V

V

V

VV

V

N

N

N

N

N

N

NN

N 4

1

65

3

#

2

MODEL(S):-PC#

*PLACE IMPLEMENTED CHANGES INTO BOARD HISTORY

PENDING CHANGE

X

XX

XX

PC

PCPC

PCPC

PSA1sM1449 PENDING CHANGES

XPC

6

34

#1

5

2

DATEMODEL(S):-

VER# DESCRIPTION OF CHANGE

V

VV

V

V

V

D

DD

D

N

NN

N

PSA1s

D

D

N

N

M1449.PCB_DATABASE_HISTORY

12

9

6

3

#

13

1110

54

87

21

DATEMODEL(S):-

VER# DESCRIPTION OF CHANGE

D V ND V N

N

PSA1sM1449 PCB HISTORY

03-JUN-2011 V0128-NOV-2011 V01 PC8329 - MARKED 'WOOFER SHUTDOWN' CIRCUIT

PARTS AS DNS. - ML. .V02

Changed R39/R40 from YS#6123 to YS#6116. - MLRenamed R65/R67 to ZD65/ZD67. - MLChanged R65/R67 from YS#6459 to YS#5124. - ML

PC8313 - C44 moved away from U9. - ML

PC8358 - YS#4100 XLR changed to YS#4135. - ML.....

.

.

.

.

.

19-DEC-2011

PC8447 - Changed C43 from 5216 to 5212. - ML.Force updated large PSU caps with slots. - ML

07-MAY-2012.12-JUL-2012 PC8458 - Changed pot 4434 to 4459. - ML

11

8

5

2

12

9

6

13

10

7

34

1

D

D

D

D

V

V

V

V

N

N

N

N

D

D

D

D

D

D

DD

D

V

V

V

V

V

V

VV

V

N

N

N

N

N

N

NN

N

Page 12: Paraline Sm Psa1s

PSA1s Parts List 8/13/2012YS No. Description Qty. YS No. Description Qty.

6405 RED 3MM LED 2V0 20MA BRT 1 4588 1/4W 2K43 1% T&R RES 16400 YEL 3MM LED 1V9 6MA HIGHEFF 1 4827 1/4W 4K7 5% T&R RES 36408 GRN 3MM LED 1V9 5MA FROSTED 1 6128 1/4W 4K99 1%MINI MF T&R RES 16772 BRIDGE 25A 400V WIRE LEAD SIP 1 4962 2.0W 5K1 5% T&R RES 26825 1N4148 75V 0A45 DIODE T&R 20 5001 1/4W 6K04 1% T&R RES 16438 1N4007 1000V 1A0 DIODE T&R 4 4762 1/4W 9K760 0.1% *** T&R RES 26450 1N5242B 12V0 0W5 ZENER 5% T&R 2 5016 1.0W 9K760 0.5% *** T&R RES 25124 1N5338B 5V1 5W0 ZENER 5% T&R 2 4829 1/4W 10K 5% T&R RES 86736 L7905CV TO220 N 5V0 REG 1 6116 1/4W 10K0 1%MINI MF T&R RES 66738 MC7805CT TO220 P 5V0 REG 36V 1 4830 1/4W 15K 5% T&R RES 36871 MC7915CT TO220 N 15V0 REG V2 1 4784 1/4W 17K40 0.1% *** T&R RES 26872 MC7815CT TO220 P 15V0 REG V1 1 6123 1/4W 20K0 1%MINI MF T&R RES 65102 BC560C TO92 PNP TRAN T&R TB 1 4777 1/4W 21K5 1% T&R RES 25103 MPSA06 TO92 NPN TRAN T&R TA 1 4832 1/4W 22K 5% T&R RES 15107 2N5551 TO92 NPN TRAN T&R TA 2 4902 1/4W 24K 5% T&R RES 45108 2N5401 TO92 PNP TRAN T&R TA 1 4833 1/4W 27K 5% T&R RES 55105 MPSA13 TO92 NPN DARL T&R TA 1 4917 1/4W 31K6 1% T&R RES 36804 MC33079P IC QUAD OP AMP 2 4803 1/4W 49K9 1% T&R RES 46882 TL072CP IC FET DUAL OP AMP 2 4836 1/4W 68K 5% T&R RES 36889 TL074CN IC QUAD O/A T.I ONLY 2 4776 1/4W 113K 1% T&R RES 36745 LM13600N IC XCONDUCTANCE AMP 1 4839 1/4W 150K 5% T&R RES 36971 MC9S08QD2CPC MICROCONTROLLER DIP8 1 4841 1/4W 220K 5% T&R RES 26489 __5R 20% THERM-SURGR NTC KNK LEADS 1 4843 1/4W 470K 5% T&R RES 16543 48R 265V RESETTABLE THERMISTOR PTC 1 4751 1/4W 22M 5% T&R RES 15817 _15P 100V 2%CAP T&R RAD CER.2NPO 2 3083 CABLE 02 16AWG 29.0 PMT TWST 3P VD2 25199 100P 100V 2%CAP T&R RAD CER.2NPO 2 3081 PATCH 08 18AWG 09.0 PMT 9P VOID9 15416 470P 50V 10%CAP T&R BEAD NPO 4 3082 PATCH 09 18AWG 03.0 PMT 16451 __4N7 250V 20%CAP BLK 'Y' 10MM AC 2 4128 10" 14C-28AWG RIBBON DIL SOCKETS 25223 _39N 100V 10%CAP T&R RAD .2FLM 2 4127 RELAY 1A 10AMP DC12 017MA PC-S 15212 100N 63V 5%CAP T&R RAD .2FLM 20 8811 #6 X 1 1/4 FLAT HD SQ SCKT WS ZN CL 425229 150N 63V 10%CAP T&R RAD .2FLM 1 9401SS #10 X 3/4 SS PAN PH TYPE A BO&W 305231 220N 63V 5%CAP T&R RAD .2FLM 1 8741 4-40 X 1/2 PAN PH MS JS500 15234 470N 63V 10%CAP T&R RAD .2FLM 2 8827 4-40 X 1/2 FLAT PH TAPTITE JS500 45262 __1U 275V 20%CAP BLK 'X2'26.0MM AC 1 8808 4-40 X 3/4 FLAT PHIL MS B.O.& WAX 65260 _22U 50V 20%CAP T&R RAD .2EL 2 8819 4-40 X 1.25 FLAT PH MS BLK ROHS 25267 100U 25V 20%CAP T&R RAD .2EL 4 8801 6-32 X 3/8 PAN PH TAPTITE JS500 55616 3300U 50V 20%CAP BLK 18X35MM EL 2 8829 6-32 X 3/8 FLAT PH TAPTITE BO#C HEA 35857 4700U 160V 20%CAP RAD 40X63MM 5PIN 4 8837 6-32 X 1/2 ROUND PH MS JS500 84459 _10K B LIN 9MM DET HI TORQ P32 1 8828 6-32 X 3/4 PAN PH TAPTITE JS500 33606 12.00 AMP CIRCUIT BREAKER 1 8833 10-32 X 7/8 IND HEX M/S BLACK OXIDE 13804 SNAP ON 1.500" INSULATING BUSHING 2 8786 10-32 X 1 1/4 PAN QD MS JS500 BLACK 163899 __18UH MINI INDUCTOR HI-Q T&R 1 9414SS 10-32X1 1/4 PAN PHIL SS MS B.O.&WAX 188529 RUBBER FOOT 65 X 20MM 4 8780 5/16-18 X 3 3/4 CARRIAGE BOLT FT ZN 18545 RECESSED RUBBER BUMPER WITH WASHER 4 9404SS 1/4-20X23MM SS JOINT CONN BOLT BO&W 89970 RIGID CASTER 2 9407SS 1/4-20 X 1 3/4 SS FLAT PHIL MS BO&W 63470 CLIP 250X032 14-16AWG DISCO-LOK 9 9419SS 1/4-20X11/4 SS TRUSS PH MS B.O.&WAX 163492 GROUND LUG FOR NO8-10 STUD 1 4088 IEC POWER V-LOCK INLET 13601 RING TERMINAL 16AWG WIRE & #8 SCREW 1 2355 NYLON STANDOFF NUT #4 375MIL 64063 1/4IN ISO JCK PCMT VT STER RT SWT 2 4007 CUSTOM .9 LED SPACER 34010 XLR FEML PCB MT VERT 24MM AA-SERIES 1 2345 NYLON STANDOFF NUT #4 1INCH 24135 XLR MALE PCB MT VERT 24MM BA-SERIES 1 8657 6-32 X 3/8" HEX SPACER ALUMINUM 22486 _1.5 AMP SLO-BLO T&R FUSE 2 7517 12" 4R 600WPGM SPKR 28565 BAR HANDLE ALL METAL RECTANGULAR 3 8482 3/8 1D FLAT WASHER 29170 STAND ADAPTER CAST 1 8818 3/4 OD X 3/8 ID X .080 THICK WASHER 13501 B52200F006 COMP WASH #4 SMALL 1 3522 DPDT MINI PC VERT SNP ALT 13977 QUAD XSISTOR SPRING, ZINC YELLOW 1 3587 DPDT ROKR SW QUIK 250"AC/PWR ON-OFF 13803 NYLON SECUR-A-TACH MINI PLASTIC TIE 1 CH1415U XFMR:PSA1S 13810 4" NYLON CABLE TIE 42359 14 CIR HEADERDIL RA 0.1 24166 06 CIR DUAL ROW HDR HT 0.1 RA 14067 09 CIR PMT-HEADER 0.156IN 14093 CONN PLUG 2 POS. .084" V-2 FEMALE 14162 2 PIN POWER PIN HEADER MALE POLZED 34146 3 PIN POWER PIN HEADER MALE POLZED 14147 6 PIN POWER PIN HEADER MALE POLZED 13576 SOCKET TERMINAL 14-20 AWG TAPE/REEL 28637 ROUND PUSH BUTTON 1/4" BLK 24MM 18653 LOW PROFILE POINTER AT 12 KNOB 13817 _1.5MH COIL INPUT COM MODE 18701 4-40 KEPS NUT ZINC 18800 6-32 KEPS NUT ZINC 58604 10-32 T NUT 348841 10-32 KEPS NUT TIN PLATED 18602 1/4-20 T NUT 208898 1/4-20 CAGE NUT C79 98142027 89977 5/16-18 NYLON INSERT LOK NUT ZN CLR 14022 ELASTOMER PAD - 4-TO220 1X1.850 18581 CUSTOM PBL TRANSISTOR SPACER 14599 22AWG SOLID SC WIR T&R JMP 24819 1/4W 180R 5% T&R RES 14770 1/4W 249R 1% T&R RES 44821 1/4W 470R 5% T&R RES 26151 1/4W 619R 1%MINI MF T&R RES 44743 1/4W 681R 0.1% *** T&R RES 24822 1/4W 820R 5% T&R RES 24824 1/4W 1K5 5% T&R RES 24847 1/4W 2K2 5% T&R RES 2