2
Page 1 of 2 SUBMITTAL Cooling (Btu/h) Heating (Btu/h) Model Type Output (W) Sound Level Single Unit EEV Kit MEV-A13SA Accessories AVXWVH020CE Condensate Pump ASP-MO-230 Safety Certifications ETL & ETLc 11 1/4 7 1/2 19 31/21 Vivace High Wall Evaporator (Heat Pump & Heat Recovery Systems) R410A Electronic Expansion Valve (external to unit) 1/4" Refrigerant Piping Connections (inches) Unit Dimensions Weight (lbs.) Performance Capacity Condensate (pints/hour) Power Heating High Airflow (CFM) Fan Type Depth (inches) Height (inches) Specifications YDK-016S1408-01 Feedback SSR 23 247 258 Cooling High Motor 1/2" ID 11/16" Hose 32 1/2 6,000 7,000 2.4 High/Low (Db) 1/208-230/60 0.13 Voltage (ø/V/Hz) Running Current (amps) Width (inches) Control Method Type Liquid (flare) Drain Suction (flare) Crossflow Electro-static, washable, silver coated main filter as standard Supplemental, replicable, anti-allergy and deodorizing filters as standard MPI Generator that eliminates airborne biological contaminants Motorized front panel Digital status/function display on front panel Construction UL94 V0 chassis with galvanized steel mounting bracket Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single, antibacterial crossflow type Three fan speed settings and auto setting Controls The unit ships with a wireless controller as standard The unit shall be operated via a wireless or wired remote control with DDC type signal The unit shall integrate with the Samsung Controls Network Solution Controls shall integrate with a BMS system Control wiring shall be 16AWG shielded wire www.SamsungSystemAC.com Quietside maintains a policy of ongoing development, specifications are subject to change without notice. *Nominal cooling capacities are based on: Indoor temperature: 80F DB, 67F WB. Outdoor temperature: 95F DB, 75F WB. *Nominal heating capacities are based on: Indoor temperature: 70F DB, 60F WB. Outdoor temperature: 47F DB, 43F WB. QS-DVM-0312A

Page 1 of 2 SUBMITTAL AVXWVH020CE - Samsung …€¦ · Page 1 of 2 SUBMITTAL Cooling (Btu/h) Heating (Btu/h) Model ... Condensate Pump ASP-MO-230 Safety Certifications ETL & ETLc

  • Upload
    dangbao

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Page 1 of 2 SUBMITTAL AVXWVH020CE - Samsung …€¦ · Page 1 of 2 SUBMITTAL Cooling (Btu/h) Heating (Btu/h) Model ... Condensate Pump ASP-MO-230 Safety Certifications ETL & ETLc

Page 1 of 2

SUBMITTAL

Cooling (Btu/h)

Heating (Btu/h)

Model

Type

Output (W)

Sound Level

Single Unit EEV Kit MEV-A13SAAccessories

AVXWVH020CE

Condensate Pump ASP-MO-230

Safety Certifications ETL & ETLc

11 1/4

7 1/2

19

31/21

Vivace High Wall Evaporator (Heat Pump & Heat Recovery Systems)

R410A

Electronic Expansion Valve (external to unit)

1/4"

Refrigerant

Piping Connections (inches)

Unit Dimensions

Weight (lbs.)

PerformanceCapacity

Condensate (pints/hour)

Power

Heating HighAirflow (CFM)

Fan

Type

Depth (inches)

Height (inches)

Specifications

YDK-016S1408-01

Feedback SSR

23

247

258

Cooling High

Motor

1/2"

ID 11/16" Hose

32 1/2

6,000

7,000

2.4

High/Low (Db)

1/208-230/60

0.13

Voltage (ø/V/Hz)

Running Current (amps)

Width (inches)

Control Method

Type

Liquid (flare)

Drain

Suction (flare)

Crossflow

������� ���� ����������� ��� ������� ������ �������� ���� ���� �� ���������

����������������� �������� ��������������� ������!�������� ������������

• Electro-static, washable, silver coated main filter as standard

• Supplemental, replicable, anti-allergy and deodorizing filters as standard

• MPI Generator that eliminates airborne biological contaminants

• Motorized front panel

• Digital status/function display on front panel

ConstructionUL94 V0 chassis with galvanized steel mounting bracket

Heat ExchangerThe heat exchanger shall be mechanically bonded fin to copper tube

Indoor FanIndoor fan is a single, antibacterial crossflow type

Three fan speed settings and auto setting

ControlsThe unit ships with a wireless controller as standard

The unit shall be operated via a wireless or wired remote control with DDC type signal

The unit shall integrate with the Samsung Controls Network Solution

Controls shall integrate with a BMS system

Control wiring shall be 16AWG shielded wire

www.SamsungSystemAC.com

Quietside maintains a policy of ongoing development, specifications are subject to change without notice.

*Nominal cooling capacities are based on: Indoor temperature: 80�F DB, 67�F WB. Outdoor temperature: 95�F DB, 75�F WB.*Nominal heating capacities are based on: Indoor temperature: 70�F DB, 60�F WB. Outdoor temperature: 47�F DB, 43�F WB.

QS-DVM-0312A

Page 2: Page 1 of 2 SUBMITTAL AVXWVH020CE - Samsung …€¦ · Page 1 of 2 SUBMITTAL Cooling (Btu/h) Heating (Btu/h) Model ... Condensate Pump ASP-MO-230 Safety Certifications ETL & ETLc

SUBMITTAL Vivace High Wall Evaporator (Heat Pump & Heat Recovery Systems)AVXWVH020CE Page 2 of 2

Unit: inches

"""#��������$����!#���%%%&'((&')'*

Ø 2 1/2"

4 3/4" 2 11/16"

1 1/16"1 1/16"

Pipe hole locations for straight-through wall penetrations

5" Minimum5" Minimum

11 1/2" Minimum

Minimum clearances from walls and ceiling

Liquid Pipe ConnectionGas Pipe ConnectionDrain Pipe ConnectionOptional Cabinet Penetration OpeningAir Inlet GrilleAir Outlet Louver

123456

NameNo. DescriptionØ 1/4" FlareØ 1/2" Flare

ID 11/16" Hose---

BOTTOM

FRONT

LEFT RIGHT

BACK

32 1/2"1 3/4"

2 1/4"3 3/8"

2 1/4"5 1/2"

15"

7 1/2"

2 1/4

"

2 1/2

"

1 1/4

"

1 5/8

"

Mounting Bracket