3
Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction Unit Designation: Schedule No.: Cooling* Rated Capacity ............................... 24,000 Btu/h Minimum Capacity ............................ 12,000 Btu/h SEER ......................................17.0 Btu/h/W Total Input ...................................... 2,270 W Heating at 47°F* Rated Capacity ............................... 26,000 Btu/h Minimum Capacity ............................ 12,000 Btu/h HSPF (IV) ...................................10.8 Btu/h/W Total Input .......................................2,330 W Heating at 17°F* Rated Capacity ............................... 18,000 Btu/h Total Input ...................................... 2,200 W * Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB / 67ºF (19ºC) WB. Outdoor: 95ºF (35ºC) DB / 75ºF (24ºC) WB. (Heating) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 47ºF (8ºC) DB / 43ºF (6ºC) WB. (Heating at 17ºF) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 17ºF (-8ºC) DB / 15ºF (-9ºC) WB. Electrical Requirements Power Supply .................... 208 / 230V, 1-Phase, 60 Hz Breaker Size ........................................25 A Voltage Indoor - Outdoor S1-S2 ...................... AC 208 / 230V Indoor - Outdoor S2-S3 ............................DC 24V Wireless Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC OPERATING RANGE Indoor Intake Air Temp. Outdoor Intake Air Temp. Cooling Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB 115ºF (46ºC) DB Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB 0ºF** (-18ºC) DB Heating Maximum 80ºF (27ºC) DB, 67ºF (19ºC) WB 70ºF (21ºC) DB, 59ºF (15ºC) WB Minimum 70ºF (21ºC) DB, 60ºF (16ºC) WB 12ºF (-11ºC) DB, 10ºF (-12ºC) WB ** With optional wind baffle accessory installed. If not installed, the minimum Indoor Unit: PKA-A24KAL Outdoor Unit: PUZ-A24NHA3 temperature will be 23ºF (-5ºC) DB. Indoor Unit MCA .............................................. 1 A Fan Motor ................................... 0.36 F.L.A. Fan Motor Output ................................... 56 W Airflow (Lo - Mid - Hi) ................ 635 - 705 - 775 Dry CFM 570 - 635 - 700 Wet CFM Air Filter ........................ Polypropylene Honeycomb Sound Pressure Level (Lo - Mid - Hi)....................39 - 42 - 45 dB(A) DIMENSIONS UNIT INCHES / MM W 46-1/16 / 1,170 D 11-5/8 / 295 H 14-3/8 / 365 Weight..................................... 46 lbs. / 21 kg External Finish .................... Munsell No. 1.0Y 9.2 / 0.2 Field Drainpipe Size O.D........................ 5/8" / 16 mm Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wireless Outdoor Unit Compressor .................. DC Inverter-driven Twin Rotary MCA ............................................. 18 A Fan Motor .................................... 0.75 F.L.A. Sound Pressure Level Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 dB(A) Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 dB(A) DIMENSIONS INCHES / MM W 37-3/8 / 950 D 13 + 1-3/16 / 330 + 30 H 37-1/8 / 943 Weight ................................... 165 lbs. / 75 kg External Finish ...................... Munsell No. 3Y 7.8 / 1.1 Refrigerant Type .................................. R410A Refrigerant Pipe Size O.D. Gas Side ................................ 5/8" / 15.88 mm Liquid Side................................ 3/8" / 9.52 mm Max. Refrigerant Pipe Length..................... 165' / 50 m Max. Refrigerant Pipe Height Difference ............ 100' / 30 m Connection Method ................................ Flared SUBMITTAL DATA: PKA-A24KAL & PUZ-A24NHA3 24,000 BTU/H WALL-MOUNTED HEAT-PUMP SYSTEM Wireless Remote Controller OPTIONAL ACCESSORIES Indoor Unit • External Heat Adapter (PAC-YU25HT) • CN24 Relay Kit (CN24RELAY-KIT-CM) • Remote Temperature Sensor (PAC-SE41TS-E) Outdoor Unit • M-NET Adapter (PAC-SF80MA-E) • Air Outlet Guide (PAC-SG59SG-E) • Wind Baffle (WB-PA2) GENERAL FEATURES • Wall-mounted indoor unit for residential and commercial applications • Shiny-white–exterior plastic; compact design • Quiet operation—both indoor and outdoor units • Wireless remote controller is included • Self-check function—integrated diagnostics • Limited warranty: five years on parts and defects and seven years on compressors

SUbMittal Data: pKa-a24Kal & pUZ-a24nHa3 24,000 btU/H … · gEnERal FEatURES • Wall-mounted indoor unit for residential and commercial : ... Specifications are subject to change

Embed Size (px)

Citation preview

Page 1: SUbMittal Data: pKa-a24Kal & pUZ-a24nHa3 24,000 btU/H … · gEnERal FEatURES • Wall-mounted indoor unit for residential and commercial : ... Specifications are subject to change

Job Name: Location: Date:

Purchaser: Engineer:

Submitted to: For Reference Approval Construction

Unit Designation: Schedule No.:

Cooling*Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24,000 Btu/hMinimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000 Btu/hSEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17.0 Btu/h/WTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,270 WHeating at 47°F*Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26,000 Btu/hMinimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000 Btu/hHSPF (IV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.8 Btu/h/WTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2,330 WHeating at 17°F*Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18,000 Btu/hTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,200 W* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB / 67ºF (19ºC) WB. Outdoor: 95ºF (35ºC) DB / 75ºF (24ºC) WB.(Heating) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 47ºF (8ºC) DB / 43ºF (6ºC) WB. (Heating at 17ºF) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 17ºF (-8ºC) DB / 15ºF (-9ºC) WB.

Electrical RequirementsPower Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 HzBreaker Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 AVoltageIndoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230VIndoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC 24VWireless Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC

OpERating RangEIndoor Intake Air Temp. Outdoor Intake Air Temp.

CoolingMaximum 95ºF (35ºC) DB, 71ºF (22ºC) WB 115ºF (46ºC) DBMinimum 67ºF (19ºC) DB, 57ºF (14ºC) WB 0ºF** (-18ºC) DB

HeatingMaximum 80ºF (27ºC) DB, 67ºF (19ºC) WB 70ºF (21ºC) DB, 59ºF (15ºC) WBMinimum 70ºF (21ºC) DB, 60ºF (16ºC) WB 12ºF (-11ºC) DB, 10ºF (-12ºC) WB

** With optional wind baffle accessory installed. If not installed, the minimum

Indoor Unit: PKA-A24KAL

Outdoor Unit: PUZ-A24NHA3temperature will be 23ºF (-5ºC) DB.

indoor UnitMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 AFan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.36 F.L.A.Fan Motor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 WAirflow (Lo - Mid - Hi) . . . . . . . . . . . . . . . . 635 - 705 - 775 Dry CFM 570 - 635 - 700 Wet CFMAir Filter . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene HoneycombSound Pressure Level (Lo - Mid - Hi). . . . . . . . . . . . . . . . . . . .39 - 42 - 45 dB(A)

DiMEnSiOnS Unit inCHES / MMW 46-1/16 / 1,170D 11-5/8 / 295H 14-3/8 / 365

Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 lbs. / 21 kgExternal Finish . . . . . . . . . . . . . . . . . . . . Munsell No. 1.0Y 9.2 / 0.2Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . . .5/8" / 16 mmRemote Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wireless Outdoor UnitCompressor . . . . . . . . . . . . . . . . . . DC Inverter-driven Twin RotaryMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 AFan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.75 F.L.A.Sound Pressure Level Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 dB(A) Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 dB(A)

DiMEnSiOnS inCHES / MMW 37-3/8 / 950D 13 + 1-3/16 / 330 + 30H 37-1/8 / 943

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165 lbs. / 75 kgExternal Finish . . . . . . . . . . . . . . . . . . . . . .Munsell No. 3Y 7.8 / 1.1Refrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410ARefrigerant Pipe Size O.D. Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8" / 15.88 mm Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9.52 mmMax. Refrigerant Pipe Length. . . . . . . . . . . . . . . . . . . . . 165' / 50 mMax. Refrigerant Pipe Height Difference . . . . . . . . . . . . 100' / 30 mConnection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flared

SUbMittal Data: pKa-a24Kal & pUZ-a24nHa3 24,000 btU/H Wall-MOUntED HEat-pUMp SYStEM

Wireless Remote Controller

OptiOnal aCCESSORiES indoor Unit• External Heat Adapter (PAC-YU25HT)• CN24 Relay Kit (CN24RELAY-KIT-CM)• Remote Temperature Sensor (PAC-SE41TS-E)

Outdoor Unit• M-NET Adapter (PAC-SF80MA-E)• Air Outlet Guide (PAC-SG59SG-E)• Wind Baffle (WB-PA2)

gEnERal FEatURES• Wall-mounted indoor unit for residential and commercial applications• Shiny-white–exterior plastic; compact design• Quiet operation—both indoor and outdoor units• Wireless remote controller is included• Self-check function—integrated diagnostics• Limited warranty: five years on parts and defects and seven years

on compressors

Page 2: SUbMittal Data: pKa-a24Kal & pUZ-a24nHa3 24,000 btU/H … · gEnERal FEatURES • Wall-mounted indoor unit for residential and commercial : ... Specifications are subject to change

Dimensions: PKA-A24KAL

Page 3: SUbMittal Data: pKa-a24Kal & pUZ-a24nHa3 24,000 btU/H … · gEnERal FEatURES • Wall-mounted indoor unit for residential and commercial : ... Specifications are subject to change

3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice.C SD - PKA-A24KAL / PUZ-A24NHA3 - 200907 © MITSUBISHI ELECTRIC / HVAC 2009

Dimensions: PUZ-A24nHA3

Cle

aran

ce A

rea