369
8/13/2019 optical switching comprehensive guide http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 1/369 L1 - 1 © P. Raatikainen Switching Technology / 2005  Optics Switching Technology L1 - 2 © P. Raatikainen Switching Technology / 2005 General Lecturer:Pertti Raatikainen, research professor /VTT email: [email protected] Exercises: Kari Seppänen, snr. research scientist /VTT email: kari.seppä[email protected] Information: http://www.netlab.hut.fi/opetus/s38165

optical switching comprehensive guide

Embed Size (px)

Citation preview

Page 1: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 1/369

L1 - 1© P. Raatikainen Switching Technology / 2005

  Optics Switching

Technology

L1 - 2© P. Raatikainen Switching Technology / 2005

General

• Lecturer:Pertti Raatikainen, research professor /VTTemail: [email protected]

• Exercises:Kari Seppänen, snr. research scientist /VTTemail: kari.seppä[email protected]

• Information: http://www.netlab.hut.fi/opetus/s38165

Page 2: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 2/369

L1 - 3© P. Raatikainen Switching Technology / 2005

Goals of the course

• Understand what switching is about

• Understand the basic structure and functions of aswitching system

• Understand the role of a switching system in atransport network

• Understand how a switching system works

• Understand technology related to switching• Understand how conventional circuit switching is

related to packet switching

L1 - 4© P. Raatikainen Switching Technology / 2005

Course outline

• Introduction to switching – switching in general

 – switching modes – transport and switching

• Switch fabrics – basics of fabric architectures

 – fabric structures

 – path search, self-routing and sorting

Page 3: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 3/369

L1 - 5© P. Raatikainen Switching Technology / 2005

Course outline

• Switch implementations – PDH switches

 – ATM switches

 – routers

• Optical switching – basics of WDM technology

 – components for optical switching

 – optical switching concepts

L1 - 6© P. Raatikainen Switching Technology / 2005

Course requirements

• Preliminary information

 – S-38.188 Tietoliikenneverkot orS-72.423 Telecommunication Systems

(or a corresponding course)

• 13 lectures (á 3 hours) and 7 exercises (á 2 hours)

• Calculus exercises

• Grating

 – Calculus 0 to 6 bonus points – valid in exams in 2005

 – Examination, max 30 points

Page 4: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 4/369

L1 - 7© P. Raatikainen Switching Technology / 2005

Course material

• Lecture notes

• Understanding Telecommunications 1, Ericsson & Telia,Studentlitteratur, 2001, ISBN 91-44-00212-2, Chapters 2-4.

• J. Hui: Switching and traffic theory for integrated broadband networks ,Kluwer Academic Publ., 1990, ISBN 0-7923-9061-X, Chapters 1 - 6.

• H. J. Chao, C. H. Lam and E. Oki: Broadband Packet Switchingtechnologies – A Practical Guide to ATM Switches and IP routers , John

Wiley & Sons, 2001, ISBN 0-471-00454-5.• T.E. Stern and K. Bala: Multiwavelength Optical Networks: A Layered

Approach , Addison-Wesley, 1999, ISBN 0-201-30967-X.

L1 - 8© P. Raatikainen Switching Technology / 2005

Additional reading

• A. Pattavina: Switching Theory - Architecture and Performance inBroadband ATM Networks , John Wiley & Sons (Chichester), 1998,IBSN 0-471-96338-0, Chapters 2 - 4.

• R. Ramaswami and K. Sivarajan, Optical Networks, A PracticalPerspective , Morgan Kaufman Publ., 2nd Ed., 2002, ISBN 1-55860-655-6.

Page 5: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 5/369

L1 - 9© P. Raatikainen Switching Technology / 2005

ScheduleDay L/E Topic

18.1. L Int roduction to switching

25.1. L Transmission techniques and multiplexing

27.1. E Exercise 1

1.2. L Basic concepts of switch fabrics

8 .2. L Multistage fabr ic architectures 1

10.2. E Exercise 2

15.2. L Multistage fabr ic architectures 2

22.2. L Self - rout ing and sort ing networ ks

24.2. E Exercise 3

1.3. L Switch fabric implementat ions

8.3. L PDH switches

10.3. E Exercise 4

15.3. L ATM switches

17.3. E Exercise 5

22.3. L Routers

5 .4. L Introduction to opt ical networks

7.4. E Exercise 6

12.4. L Optical network architectures

19.4. L Optical switches

21.4. E Exercise 7

L1 - 10© P. Raatikainen Switching Technology / 2005

Introduction to switching

Switching Technology S38.165

http://www.netlab.hut.fi/opetus/s38165

Page 6: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 6/369

L1 - 11© P. Raatikainen Switching Technology / 2005

Introduction to switching

• Switching in general

• Switching modes

• Transport and switching

L1 - 12© P. Raatikainen Switching Technology / 2005

Switching in general

ITU-T specification for switching:

“The establishing, on-demand, of an individual

connection from a desired inlet to a desired outlet

within a set of inlets and outlets for as long as is

required for the transfer of information.”

inlet/outlet = a line or a channel

Page 7: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 7/369

L1 - 13© P. Raatikainen Switching Technology / 2005

Switching in general (cont.)

• Switching implies directing of information flows incommunications networks based on known rules

• Switching takes place in specialized network nodes

• Data switched on bit, octet, frame or packet level

• Size of a switched data unit is variable or fixed

L1 - 14© P. Raatikainen Switching Technology / 2005

Why switching ?

• Switches allow reduction in overall network cost by reducingnumber and/or cost of transmission links required to enable agiven user population to communicate

• Limited number of physical connections implies need forsharing of transport resources, which means

 – better utilization of transport capacity

 – use of switching

• Switching systems are central components incommunications networks

Page 8: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 8/369

L1 - 15© P. Raatikainen Switching Technology / 2005

Full connectivity between hosts

Full meshNumber of links to/from a host = n-1

Total number of links = n(n-1)/2

L1 - 16© P. Raatikainen Switching Technology / 2005

Centralized switching

Number of links to/from a host = 1

Total number of links = n

Page 9: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 9/369

L1 - 17© P. Raatikainen Switching Technology / 2005

Switching network to connect hosts

Number of links to/from a host = 1

Total number of links depends

on used network topology

L1 - 18© P. Raatikainen Switching Technology / 2005

Hierarchy of switching networks

Local

switchingnetwork

Long distanceswitching network

To higher level of hierarchy

Page 10: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 10/369

L1 - 19© P. Raatikainen Switching Technology / 2005

Sharing of link capacity

Space Division Multiplexing (SDM)

1

2

n

 . . .

3 ...Physical

link

CH 1

CH 2

CH n

Physicallink

1

2

n

...3

Space to be divided:- physical cable or twisted pair - frequency- light wave

L1 - 20© P. Raatikainen Switching Technology / 2005

Sharing of link capacity (cont.)

1

2

n . . .

1

2

n

...

123n12 …...   n-1

Synchronous transfer mode (STM)

k Overhead Payload

Asynchronous transfer mode (ATM)

1

2

n . . .

1

2

n

...

12n1...   idle 21 idle

Time Division Multiplexing (TDM)

Page 11: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 11/369

L1 - 21© P. Raatikainen Switching Technology / 2005

Main building blocks of a switch

InputInterfaceCard #1

InputInterfaceCard #1

Inputinterface #1

Switchfabric

OutputInterfaceCard #1

OutputInterfaceCard #1

Outputinterface #1

Switch control

• input signal reception

• error checking and recovery• incoming frame disassembly• buffering• routing/switching decision

• switching of data units from

input interfaces to destinedoutput interfaces

• limited buffering

• buffering, prioritizing and

scheduling• outgoing frame assembly• output signal generation and

transmission

• processing of signaling/connection control information• configuration and control of input/output interfaces and switch fabric

L1 - 22© P. Raatikainen Switching Technology / 2005

Heterogeneity by switching

• Switching systems allow heterogeneity among terminals

 – terminals of different processing and transmission speeds supported

 – terminals may implement different sets of functionality

• and heterogeneity among transmission links by providing avariety of interface types

 – data rates can vary

 – different link layer framing applied

 – optical and electrical interfaces

 – variable line coding

Page 12: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 12/369

L1 - 23© P. Raatikainen Switching Technology / 2005

Heterogeneity by switching (cont.)

 …

Subscriber mux

 …

 …

Remotesubscriber 

switch

Analog interface

ISDN (2B+D) or E1

E1 or E2

E1, E2 or E3

L1 - 24© P. Raatikainen Switching Technology / 2005

Basic types of witching networks

• Statically switched networks

– connections established for longer periods of time(typically for months or years)

– management system used for connection manipulation

• Dynamically switched networks

– connections established for short periods of time (typically fromseconds to tens of minutes)

– active signaling needed to manipulate connections

• Routing networks– no connections established - no signaling

– each data unit routed individually through a network

– routing decision made dynamically or statically

Page 13: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 13/369

L1 - 25© P. Raatikainen Switching Technology / 2005

Development of switching technologies

1950 1960 199019801970 2000 20202010

SPC, analog switching

Crossbar switch

Manual SPC - stored program control

Step-by-step

SPC, digital switching

Broadband,electronic

Broadband,optical

Source: Understanding Telecommunications 1, Ericsson & Telia, Studentlitteratur, 2001.

L1 - 26© P. Raatikainen Switching Technology / 2005

Development of switching tech. (cont.)

• Manual systems

– in the infancy of telephony, exchanges were built up with manually operated switching

equipment (the first one in 1878 in New Haven, USA)

• Electromechanical systems

– manual exchanges were replaced by automated electromechanical switching systems– a patent for automated telephone exchange in 1889 (Almon B. Strowger)

– step-by-step selector controlled directly by dial of a telephone set

– developed later in the direction of register-controlled system in which number

information is first received and analyzed in a register – the register is used to select

alternative switching paths (e.g. 500 line selector in 1923 and crossbar system in 1937)

– more efficient routing of traffic through transmission network

– increased traffic capacity at lower cost

Page 14: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 14/369

L1 - 27© P. Raatikainen Switching Technology / 2005

Development of switching tech. (cont.)

• Computer-controlled systems

– FDM was developed round 1910, but implemented in 1950’s (ca. 1000 channels

transferred in a coaxial cable)

– PCM based digital multiplexing introduced in 1970’s – transmission quality improved – 

costs reduced further when digital group switches were combined with digital

transmission systems

– computer control became necessary - the first computer controlled exchange put into

service in 1960 (in USA)

– strong growth of data traffic resulted in development of separate data networks and

switches – advent of packet switching (sorting, routing and buffering)– N-ISDN network combined telephone exchange and packet data switches

– ATM based cell switching formed basis for B-ISDN

– next step is to use optical switching with electronic switch control – all optical switching

can be seen in the horizon

L1 - 28© P. Raatikainen Switching Technology / 2005

Roadmap of Finnish networkingtechnologies

1955 -60 -65 -70 -75 -80 -85 -90 -95 2000

Automation of long distance telephony

Digital transmission

Digitalization of Exchanges

ISDN

Data networks

WWW

Arpanet ---> Internet technology

NMT-450

NMT-900

Circuit switching Packet sw

GSM

UMTS

Page 15: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 15/369

L1 - 29© P. Raatikainen Switching Technology / 2005

Challenges of modern switching

• Support of different traffic profiles• constant and variable bit rates, bursty traffic, etc.

• Simultaneous switching of highly different data rates• from kbits/s rates to Gbits/s rates

• Support of varying delay requirements• constant and variable delays

• Scalability• number of input/output links, link bit rates, etc.

• Reliability

• Cost

• Throughput

L1 - 30© P. Raatikainen Switching Technology / 2005

Switching modes

Switching Technology S38.165

http://www.netlab.hut.fi/opetus/s38165

Page 16: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 16/369

L1 - 31© P. Raatikainen Switching Technology / 2005

Narrowband network evolution

• Early telephone systems used analog technology - frequency divisionmultiplexing (FDM) and space division switching (SDS)

• When digital technology evolved time division multiplexing (TDM) andtime division switching (TDS) became possible

• Development of electronic components enabled integration ofTDM and TDS => Integrated Digital Network (IDN)

• Different and segregated communications networks were developed

 – circuit switching for voice-only services

 – packet switching for (low-speed) data services

 – dedicated networks, e.g. for video and specialized data services

L1 - 32© P. Raatikainen Switching Technology / 2005

Segregated transport

Dedicatednetwork

Packet switchingnetwork

Circuit switchingnetwork

Voice

Data

DataVideo

Voice

Data

DataVideo

UNI UNI

Page 17: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 17/369

L1 - 33© P. Raatikainen Switching Technology / 2005

Narrowband network evolution (cont.)

• Service integration became apparent to better utilize communicationsresources=> IDN developed to ISDN (Integrated Services Digital Network)

• ISDN offered

 – a unique user-network interface to support basic set of narrowband services

 – integrated transport and full digital access

 – inter-node signaling (based on packet switching)

 – packet and circuit switched end-to-end digital connections

 – three types of channels (B=64 kbit/s, D=16 kbit/s and H=nx64 kbit/s)

• Three types of long-distance interconnections – circuit switched, packet switched and signaling connections

• Specialized services (such as video) continued to be supported byseparate dedicated networks

L1 - 34© P. Raatikainen Switching Technology / 2005

Integrated transport

Dedicatednetwork

Packet switchingnetwork

ISDNswitch

Circuit switchingnetwork

Signaling

network

ISDNswitch

UNI UNI

DataVideo

VoiceData

DataVideo

VoiceData

Page 18: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 18/369

L1 - 35© P. Raatikainen Switching Technology / 2005

Broadband network evolution

• Progress in optical technologies enabled huge transport capacities=> integration of transmission of all the different networks

(NB and BB) became possible

• Switching nodes of different networks co-located to configuremultifunctional switches

 – each type of traffic handled by its own switching module

• Multifunctional switches interconnected by broadband integrated

transmission (BIT) systems terminated onto network-node interfaces(NNI)

• BIT accomplished with partially integrated access and segregatedswitching

L1 - 36© P. Raatikainen Switching Technology / 2005

Narrowband-integrated accessand broadband-integrated transmission

Ad-hocswitch

Packetswitch

ISDNswitch

Circuitswitch

Signalingswitch

UNI

VoiceData

DataVideo

Ad-hocswitch

Packetswitch

Circuitswitch

Signalingswitch

ISDNswitch

UNI

VoiceData

DataVideo

Multifunctionalswitch

Multifunctionalswitch

NNI NNI

Page 19: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 19/369

L1 - 37© P. Raatikainen Switching Technology / 2005

Broadband network evolution (cont.)

• N-ISDN had some limitations:

 – low bit rate channels

 – no support for variable bit rates

 – no support for large bandwidth services

• Connection oriented packet switching scheme, i.e., ATM (Asynchronous

Transfer Mode), was developed to overcome limitations of N-ISDN

=> B-ISDN concept

=> integrated broadband transport and switching (no more need for

specialized switching modules or dedicated networks)

L1 - 38© P. Raatikainen Switching Technology / 2005

Broadband integrated transport

UNI

VoiceDataVideo

UNINNI NNI

B-ISDNswitch

B-ISDNswitch

VoiceDataVideo

Page 20: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 20/369

L1 - 39© P. Raatikainen Switching Technology / 2005

OSI definitions for routing and switching

Routing on L3

L2

L3

L2

L3

L2

L3

L2

L3

L2

L3

L2

L3

L4 L4

Switching on L2

L2

L3

L2

L3

L2

L3

L2

L3

L2

L3

L2

L3

L4 L4

L1 - 40© P. Raatikainen Switching Technology / 2005

Switching modes

• Circuit switching

• Cell and frame switching• Packet switching

 – Routing

 – Layer 3 - 7 switching

 – Label switching

Page 21: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 21/369

L1 - 41© P. Raatikainen Switching Technology / 2005

Circuit switching

Layer 1 Layer 1Limited error 

detection Layer 1 Layer 1Limited error 

detection

Network edge Switching node Network edge

• End-to-end circuit established for a connection

• Signaling used to set-up, maintain and release circuits

• Circuit offers constant bit rate and constant transport delay

• Equal quality offered to all connections

• Transport capacity of a circuit cannot be shared

• Applied in conventional telecommunications networks (e.g. PDH/PCM

and N-ISDN)

L1 - 42© P. Raatikainen Switching Technology / 2005

Cell switching

• Virtual circuit (VC) established for a connection

• Data transported in fixed length frames (cells), which carry information

needed for routing cells along established VCs• Forwarding tables in network nodes

Layer 1

Error recovery & flow control

Layer 1

Layer 2 (L) Layer 2 (L)

Layer 1

Layer 2 (L)

Layer 2 (H)

Limited error detection Layer 1

Limited error detection

Network edge Switching node Network edge

Error & congestioncontrol

Error & congestioncontrol

Layer 2 (L)

Layer 2 (H)

Page 22: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 22/369

L1 - 43© P. Raatikainen Switching Technology / 2005

Cell switching (cont.)

• Signaling used to set-up, maintain and release VCs as well as update

forwarding tables

• VCs offer constant or variable bit rates and transport delay

• Transport capacity of links shared by a number of connections

(statistical multiplexing)

• Different quality classes supported

• Applied, e.g. in ATM networks

L1 - 44© P. Raatikainen Switching Technology / 2005

Frame switching

• Virtual circuits (VC) established usually for virtual LAN connections

• Data transported in variable length frames (e.g. Ethernet frames), which

carry information needed for routing frames along established VCs• Forwarding tables in network nodes

Layer 1

Error recovery & flow control

Layer 1

MAC MAC

Layer 1

MAC

LLC

Limited error detection Layer 1

Limited error detection

Network edge Switching node Network edge

Error & congestioncontrol

Error & congestioncontrol

MAC

LLC

Page 23: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 23/369

L1 - 45© P. Raatikainen Switching Technology / 2005

Frame switching (cont.)

• VCs based, e.g., on 12-bit Ethernet VLAN IDs (Q-tag) or 48-bit MAC

addresses

• Signaling used to set-up, maintain and release VCs as well as update

forwarding tables

• VCs offer constant or variable bit rates and transport delay

• Transport capacity of links shared by a number of connections

(statistical multiplexing)

• Different quality classes supported

• Applied, e.g. in offering virtual LAN services for business customers

L1 - 46© P. Raatikainen Switching Technology / 2005

Packet switching

Layer 1

Layer 2

Layer 3

Layer 1

Layer 2

Layer 3

Routing & mux

Error recovery&

flow control

Layer 1

Layer 2

Layer 3

Layer 1

Layer 2

Layer 3

Routing & mux

Error recovery&

flow control

Network edge Switching node Network edge

• No special transport path established for a connection

• Variable length data packets carry information used by network nodes

in making forwarding decisions• No signaling needed for connection setup

Page 24: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 24/369

L1 - 47© P. Raatikainen Switching Technology / 2005

Packet switching (cont.)

• Forwarding tables in network nodes are updated by routing protocols

• No guarantees for bit rate or transport delay

• Best effort service for all connections in conventional packet

switched networks

• Transport capacity of links shared effectively

• Applied in IP (Internet Protocol) based networks

L1 - 48© P. Raatikainen Switching Technology / 2005

Layer 3 - 7 switching

• L3-switching evolved from the need to speed up (IP based) packet

routing

• L3-switching separates routing and forwarding

• A communication path is established based on the first packetassociated with a flow of data and succeeding packets are switched

along the path (i.e. software based routing combined with hardware

based one)

• Notice: In wire-speed routing traditional routing is implemented in

hardware to eliminate performance bottlenecks associated with software

based routing (i.e., conventional routing reaches/surpasses L3-switching

speeds)

Page 25: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 25/369

L1 - 49© P. Raatikainen Switching Technology / 2005

Layer 3 - 7 switching (cont.)

• In L4 - L7 switching, forwarding decisions are based not only on MAC

address of L2 and destination/source address of L3, but also on

application port number of L4 (TCP/UDP) and on information of layers

above L4

Layer 1

Layer 2

Layer 3

Layer 1

Layer 2

Layer 3

Flow control

Error recovery&

flow control

Layer 1

Layer 2

Layer 3

Layer 1

Layer 2

Layer 3

Routing

Error recovery&

flow control

Network edge Switching node Network edge

Layer 4 Layer 4

Layer 7 Layer 7...

...

Routing   R  o  u   t   i  n  g   i  n   f  o

L1 - 50© P. Raatikainen Switching Technology / 2005

Label switching

Layer 1

Layer 2

Layer 3

Layer 1

Layer 2

Flow control

Error recovery&

flow control

Layer 1

Layer 2

Layer 1

Layer 2

Layer 3Error recovery

&flow control

Network edge Switching node Network edge

• Evolved from the need to speed up connectionless packet switching and

utilize L2-switching in packet forwarding

• A label switched path (LSP) established for a connection

• Forwarding tables in network nodes

Page 26: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 26/369

L1 - 51© P. Raatikainen Switching Technology / 2005

Label switching (cont.)

• Signaling used to set-up, maintain and release LSPs

• A label is inserted in front of a L3 packet (behind L2 frame header)

• Packets forwarded along established LSPs by using labels in L2

frames

• Quality of service supported

• Applied, e.g. in ATM, Ethernet and PPP

• Generalized label switching scheme (GMPLS) extends MPLS to beapplied also in optical networks, i.e., enables light waves to be used

as LSPs

L1 - 52© P. Raatikainen Switching Technology / 2005

Latest directions in switching

• The latest switching schemes developed to utilize Ethernet based

transport

• Scalability of the basic Ethernet concept has been the major problem,

i.e., 12-bit limitation of VLAN ID

• Modifications to the basic Ethernet frame structure have been proposed

to extend Ethernet’s addressing capability, e.g., Q-in-Q, Mac-in-Mac,

Virtual MAN and Ethernet-over-MPLS

• Standardization bodies favor concepts (such as Q-in-Q and VMAN) that

are backward compatible with the legacy Ethernet frame

• Signaling solutions still need further development

Page 27: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 27/369

L2 - 1© P. Raatikainen Switching Technology / 2005

Transmission techniques andmultiplexing hierarchies

Switching Technology S38.165http://www.netlab.hut.fi/opetus/s38165

L2 - 2© P. Raatikainen Switching Technology / 2005

Transmission techniques and multiplexinghierarchies

• Transmission of data signals

• Timing and synchronization

• Transmission techniques and multiplexing – PDH

 – ATM

 – IP/Ethernet

 – SDH/SONET

 – OTN

 – GFP

Page 28: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 28/369

L2 - 3© P. Raatikainen Switching Technology / 2005

Transmission of data signals

• Encapsulation of user data into layered protocolstructure

• Physical and link layers implement functionality thathave relevance to switching – multiplexing of transport signals (channels/connections)

 – medium access and flow control

 – error indication and recovery

 – bit, octet and frame level timing/synchronization

 – line coding (for spectrum manipulation and timing extraction)

L2 - 4© P. Raatikainen Switching Technology / 2005

Encapsulation of user data

PLH Physical layer  

LLH Link layer payload

NLH Network layer payload

TLH T ransport layer payload

User data

• error coding/indication

• octet & frame synchronization

• addressing

• medium access & flow control

• line coding

• bit level timing

• physical signal generation/

recovery

Page 29: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 29/369

L2 - 5© P. Raatikainen Switching Technology / 2005

Synchronization of transmitted data

• Successful transmission of data requires bit, octet, frameand packet level synchronism

• Synchronous systems (e.g. PDH and SDH) carryadditional information (embedded into transmitted line

signal) for accurate recovery of clock signals

• Asynchronous systems (e.g. Ethernet) carry additional bitpatterns to synchronize receiver logic

L2 - 6© P. Raatikainen Switching Technology / 2005

Timing accuracy

• Inaccuracy of frequency classified in telecom networks to

 – jitter (short term changes in frequency > 10 Hz)

 – wander (< 10 Hz fluctuation) – long term frequency shift (drift or skew)

• To maintain required timing accuracy, network nodes areconnected to a hierarchical synchronization network

 – Universal Time Coordinated (UTC): error in the order of 10-13

 – Error of Primary Reference Clock (PRC) of the telecom network in theorder of 10-11

Page 30: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 30/369

L2 - 7© P. Raatikainen Switching Technology / 2005

Timing accuracy (cont.)

• Inaccuracy of clock frequency causes

 – degraded quality of received signal

 – bit errors in regeneration

 – slips: in PDH networks a frame is duplicated or lost due to timingdifference between the sender and receiver

• Based on applied synchronization method, networks are dividedinto

 – fully synchronous networks (e.g. SDH) – plesiochronous networks (e.g. PDH), sub-networks have nominally the

same clock frequency but are not synchronized to each other

 – mixed networks

L2 - 8© P. Raatikainen Switching Technology / 2005

Methods for bit level timing

• To obtain bit level synchronism receiver clocks must besynchronized to incoming signal

• Incoming signal must include transitions to keep receiver’sclock recovery circuitry in synchronism

• Methods to introduce line signal transitions

 – Line coding

 – Block coding

 – Scrambling

Page 31: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 31/369

L2 - 9© P. Raatikainen Switching Technology / 2005

Line coding

+V

1 1 0 1 0 0 0 0 1 1 0 0 0 0 0 0 1 1 0 1

Uncoded

+V

-V

AMI RZ

+V

ADI RZ

+V

ADI

ADI - Al ternate Digi t InversionADI RZ - Alternate Digit Inversion Return to ZeroAMI RZ - Alternate Mark Inversion Return to Zero

L2 - 10© P. Raatikainen Switching Technology / 2005

Line coding (cont.)

• ADI, ADI RZ and codes alike introduce DC balance shift

=> clock recovery becomes difficult

• AMI and AMI RZ introduces DC balance, but lacks effective ability tointroduce signal transitions

• HDB3 (High Density Bipolar 3) code, used in PDH systems, guarantees asignal transition at least every fourth bit• 0000 coded by 000V when there is an odd number of pulses since the last violation (V) pulse

• 0000 coded by B00V when there is an even number of pulses since the last violation pulse

1 1 0 1 0 0 0 0 1 1 0 0 0 0 0 0 1 1 0 1

+V

-V

HDB3B V

V

Page 32: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 32/369

L2 - 11© P. Raatikainen Switching Technology / 2005

Line coding (cont.)

• When bit rates increase (> 100 Mbit/s) jitter requirements become tighterand signal transitions should occur more frequently than in HDB3 coding

• CMI (Coded Mark Inversion) coding was introduced for electronicdifferential links and for optical links

• CMI doubles bit rate on transmission link => higher bit rate implies largerbandwidth and shortened transmission distance

1 1 0 1 0 0 0 0 1 1 0 0 0 0 0 0 1 1 0 1

+V

-V

CMI

L2 - 12© P. Raatikainen Switching Technology / 2005

Block coding

• Entire blocks of n bits are replaced by other blocks of m bits (m > n )

• nBmB block codes are usually applied on optical links by using on-offkeying

• Block coding adds variety of “1”s and “0”s to obtain better clocksynchronism and reduced jitter

• Redundancy in block codes (in the form of extra combinations) enableserror recovery to a certain extent

• When m>n the coded line signal requires larger bandwidth than the originalsignal

• Examples: 4B5B (FDDI), 5B6B (E3 optical links) and 8B10B (GbE)

Page 33: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 33/369

L2 - 13© P. Raatikainen Switching Technology / 2005

Coding examples

0 0 0 0

0 0 0 1

0 0 1 0

0 0 1 1

0 1 0 0

0 1 0 1

0 1 1 0

0 1 1 1

1 0 0 0

1 0 0 11 0 1 0

1 0 1 1

1 1 0 0

1 1 0 1

1 1 1 0

1 1 1 1

0 0 0 0 0 Quiet line symbol

1 1 1 1 1 Idle symbol

0 0 1 0 0 Halt line symbol

1 1 0 0 0 Start symbol

1 0 0 0 1 Start symbol

0 1 1 0 1 End symbol

0 0 1 1 1 Reset symbol

1 1 0 0 1 Set Symbol

0 0 0 0 1 Invalid

0 0 0 1 0 Invalid0 0 0 1 1 Invalid

0 0 1 0 1 Invalid

0 0 1 1 0 Invalid

0 1 0 0 0 Invalid

0 1 1 0 0 Invalid

1 0 0 0 0 Invalid

Inputword

Other output wordsOutputword

1 1 1 1 0

0 1 0 0 1

1 0 1 0 0

1 0 1 0 1

0 1 0 1 0

0 1 0 1 1

0 1 1 1 0

0 1 1 1 1

1 0 0 1 0

1 0 0 1 11 0 1 1 0

1 0 1 1 1

1 1 0 1 0

1 1 0 1 1

1 1 1 0 0

1 1 1 0 1

4B5B coding 5B6B coding

Input word Output word

0 0 0 0 0

0 0 0 0 1

0 0 0 1 0

0 0 0 1 1

...

1 1 1 0 0

1 1 1 0 1

1 1 1 1 0

1 1 1 1 1

1 0 1 0 1 1

1 0 1 0 1 0

1 0 1 0 0 1

1 1 1 0 0 0

...

0 1 0 0 1 1

0 1 0 1 1 1

0 1 1 0 1 1

0 1 1 1 0 0

L2 - 14© P. Raatikainen Switching Technology / 2005

Scrambling

• Data signal is changed bit by bit according to a separate repetitivesequence (to avoid long sequences of “1”s or “0”s)

• Steps of the sequence give information on how to handle bits in the

signal being coded• A scrambler consists of a feedback shift register described by a

polynomial (xN + … + xm + … + xk + … + x + 1)

• Polynomial specifies from where in the shift register feedback is taken

• Output bit rate is the same as the input bit rate

• Scrambling is not as effective as line coding

Page 34: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 34/369

L2 - 15© P. Raatikainen Switching Technology / 2005

Scrambler example

SDH/STM-1 uses x7+x6+1 polynomial

Preset

x7x6x5x4x3x2x1x0

D D D D D D D D +

+

Xi

Di

Si

Scrambler 

Xi

Preset

x7x6x5x4x3x2x1x0

D D D D D D D D +

+

Ri =Di

Si

Descrambler 

Xi = Si⊕⊕⊕⊕Di

Ri = Si⊕⊕⊕⊕Xi

= Si⊕⊕⊕⊕(Si⊕⊕⊕⊕Di) = Di

L2 - 16© P. Raatikainen Switching Technology / 2005

Methods for octet and frame level timing

• Frame alignment bit pattern

• Start of frame signal

• Use of frame check sequence

Page 35: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 35/369

L2 - 17© P. Raatikainen Switching Technology / 2005

Frame alignment sequence

• Data frames carry special frame alignment bit patterns toobtain octet and frame level synchronism

• Data bits scrambled to avoid misalignment

• Used in networks that utilize synchronous transmission,e.g. in PDH, SDH and OTN

• Examples

 – PDH E1 frames carry bit sequence 0011011 in every other frame(even frames)

 – SDH and OTN frames carry a six octet alignment sequence(hexadecimal form: F6 F6 F6 28 28 28) in every frame

L2 - 18© P. Raatikainen Switching Technology / 2005

Start of frame signal

• Data frames carry special bit patterns to synchronizereceiver logic

• False synchronism avoided for example by inserting

additional bits into data streams• Used in synchronous and asynchronous networks, e.g.,

Ethernet and HDLC

• Examples

 – Ethernet frames are preceded by a 7-octet preamble field(10101010) followed by a start-of-frame delimiter octet (10101011)

 – HDLC frames are preceded by a flag byte (0111 1110)

Page 36: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 36/369

L2 - 19© P. Raatikainen Switching Technology / 2005

Frame check sequence

• Data frames carry no special bit patterns forsynchronization

• Synchronization is based on the use of error indication andcorrection fields

 – CRC (Cyclic Redundancy Check) calculation

• Used in bit synchronous networks such as ATM and GFP(Generic Framing Procedures)

• Example – ATM cells streams can be synchronized to HEC (Header Error

Control) field, which is calculated across ATM cell header

L2 - 20© P. Raatikainen Switching Technology / 2005

Transmission techniques

• PDH (Plesiochronous Digital Hierarchy)

• ATM (Asynchronous Transfer Mode)

• IP/Ethernet

• SDH (Synchronous Digital Hierarchy)

• OTN (Optical Transport network)

• GFP (Generic Framing Procedure)

Page 37: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 37/369

Page 38: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 38/369

L2 - 23© P. Raatikainen Switching Technology / 2005

PDH E1-frame structure (odd frames)

F0 F1 . . . F14 F15

Multi- frame

T0 T1 T2 T0 . . . T15 T16 T17 . . . T28 T29 T30 T31

Voice channels 1 - 15 Voice channels 16 - 30

C 1 A D D D D D

Frame alignment time-slot

Data bits for management

Error indicator bit (CRC-4) Far end

alarm indication

a b c d a b c c

Channel 1signalingbits

Signaling time-slot

Channel 16signalingbits

Nowadays, time slot 1used for signaling and timeslot 16 for voice

L2 - 24© P. Raatikainen Switching Technology / 2005

PDH-multiplexing

• Tributaries have the same nominal bit rate, but with aspecified, permitted deviation (100 bit/s for 2.048 Mbit/s)

• Plesiochronous = tributaries have almost the same bit rate• Justification and control bits are used in multiplexed flows

• First order (E1) is octet-interleaved, but higher orders (E2,…) are bit-interleaved

Page 39: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 39/369

L2 - 25© P. Raatikainen Switching Technology / 2005

PDH network elements

• concentrator – n channels are multiplexed to a higher capacity link that carries m 

channels (n > m )

• multiplexer – n channels are multiplexed to a higher capacity link that carries n 

channels

• cross-connect

– static multiplexing/switching of user channels• switch

– switches incoming TDM/SDM channels to outgoing ones

L2 - 26© P. Raatikainen Switching Technology / 2005

Example PDH network elements

Concentrator 

 . . .

m outputchannels

     n   i  n  p  u   t

  c   h  a

  n  n  e   l  s

n > m 

 . . .

m outputchannels

     n

   i  n  p  u   t

  c   h  a  n  n  e   l  s

n = m 

Multiplexer 

Cross-connect

DXC

Switch

4

2

23

4 3 1

1

4 3 2 1 4

2

2

34

3

1

1

4 3

2

1

Page 40: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 40/369

L2 - 27© P. Raatikainen Switching Technology / 2005

Synchronous digital hierarchy

155 Mbit/s

622 Mbit/s

2.48 Gbit/s

10 Gbit/s

40 Gbit/s

x 4

x 4

x 4

STM-1

STM-4

STM-16

STM-64

STM-256

x 4

Major ITU-T SDH standards:- G.707- G.783

Notice that each frame

transmitted in 125 µs !

L2 - 28© P. Raatikainen Switching Technology / 2005

SDH reference model

- DXC Digital gross-connect- MPX Mult iplexer - R Repeater  

   T  r   i   b  u   t  a  r   i  e  s

R RSTM-n

MPX DXC MPX

   T  r   i   b  u   t  a  r   i  e  s

STM-n STM-n STM-n

Regenerationsection

Regenerationsection

Regenerationsection

Multiplexing sectionMultiplexing

section

Path layer connection

Page 41: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 41/369

L2 - 29© P. Raatikainen Switching Technology / 2005

SDH-multiplexing

• Multiplexing hierarchy for plesiochronous and synchronous tributaries(e.g. E1 and E3)

• Octet-interleaving, no justification bits - tributaries visible and available inthe multiplexed SDH flow

• SDH hierarchy divided into two groups:

 – multiplexing level (virtual containers, VCs)

 – line signal level (synchronous transport level, STM)

• Tributaries from E1 (2.048 Mbit/s) to E4 (139.264 Mbit/s) are

synchronized (using justification bits if needed) and packed in containersof standardized size

• Control and supervisory information (POH, path overhead) added tocontainers => virtual container (VC)

L2 - 30© P. Raatikainen Switching Technology / 2005

SDH-multiplexing (cont.)

• Different sized VCs for different tributaries (e.g. VC-12/E1, VC-3/E3,VC-4/E4)

• Smaller VCs can be packed into a larger VC (+ new POH)

• Section overhead (SOH) added to larger VC=> transport module

• Transport module corresponds to line signal (bit flow transferred onthe medium)

– bit rate is 155.52 Mbit/s or its multiples

– transport modules called STM-N (N = 1, 4, 16, 64, ...)

– bit rate of STM-N is Nx155.52 Mbit/s

– duration of a module is 125 µs (= duration of a PDH frame)

Page 42: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 42/369

L2 - 31© P. Raatikainen Switching Technology / 2005

SDH network elements

• regenerator (intermediate repeater, IR)

– regenerates line signal and may send or receive data viacommunication channels in RSOH header fields

• multiplexer

– terminal multiplexer multiplexes/demultiplexes PDH and SDHtributaries to/from a common STM-n

– add-drop multiplexer adds or drops tributaries to/from a common STM-n

• digital cross-connect

– used for rearrangement of connections to meet variations of capacity orfor protection switching

– connections set up and released by operator

L2 - 32© P. Raatikainen Switching Technology / 2005

Example SDH network elements

Cross-connect

DXC

STM-n

STM-n

STM-n

STM-n

STM-n

STM-n

ADM

Add-drop multiplexer 

2 - 140 Mbit/s

STM-n STM-nADM

Terminal multiplexer 

2 - 140 Mbit/s

STM-n

Page 43: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 43/369

L2 - 33© P. Raatikainen Switching Technology / 2005

Generation of STM-1 frame

VC-12PDH/E1 MUX VC-4 STM-1

Justification

+ POH + POH + SOH

L2 - 34© P. Raatikainen Switching Technology / 2005

STM-n  frame

Three main fields:

– Regeneration and multiplexer section overhead (RSOH and MSOH)

– Payload and path overhead (POH)

– AU (administrative) pointer specifies where payload (VC-4 or VC-3) starts

RSOH

AU-4 PTR

MSOH

nx9 octetsnx261 octets

3

1

5

POH

Page 44: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 44/369

L2 - 35© P. Raatikainen Switching Technology / 2005

Synchronization of payload

• Position of each octet in a STM frame (or VC frame) has a number

• AU pointer contains position number of the octet in which VC starts

• Lower order VC included as part of a higher order VC (e.g. VC-12 as partof VC-4)

RSOH

AU-4 PTR

MSOH

RSOH

AU-4 PTR

MSOH VC-4 no. 2

VC-4 no. 1

VC-4 no. 0

STM-1no. k 

STM-1no. k +1

L2 - 36© P. Raatikainen Switching Technology / 2005

• cell – 53 octets

• routing/switching – based on VPI and VCI

• adaptation – processing of user data into ATM cells

• error control – cell header checking and discarding

• flow control – no flow control

 – input rate control

• congestion control – cell discarded (two priorities)

ATM concept in summary

Page 45: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 45/369

L2 - 37© P. Raatikainen Switching Technology / 2005

Segmentation and reassembly (SAR)

Phys

ATM

AAL

Convergence sublayer (CS)

Generic flow control

VPI/VCI translation

Multiplexing and demultiplexing of cells

Timing

Physical medium

Cell rate decoupling

HEC header sequence generation/verification

Cell delineation

Transmission frame adaptation

Transmission frame generation/recovery

   T   C

   P   M

ATM protocol reference model

L2 - 38© P. Raatikainen Switching Technology / 2005

EX

TEATM

network

NNI UNI

Reference interfaces

NNI - Network-to-Network Interface

UNI - User Network Interface

EX - Exchange Equipment

TE - Terminal Equipment

Page 46: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 46/369

L2 - 39© P. Raatikainen Switching Technology / 2005

ATM cell structure

ATMheader 

ATMheader  Cell payloadCell payload

5 octets 48 octets

GFCGFC

VPIVPI

VPIVPI

VCIVCI

VCIVCI

VCIVCI

PTIPTI

CPLCPL

HECHEC

ATM header for UNI

UNI - User Network InterfaceNNI - Network-to-Network InterfaceVPI - Virtual Path Identifier VCI - Virtual Channel Identifier GFC - Generic Flow ControlPTI - Payload Type Identifier CPL - Cell Loss Priority

HEC - Header Error Control

VPIVPI

VPIVPI

VCIVCI

VCIVCI

VCIVCI

PTIPTI

CPLCPL

HECHEC

ATM header for NNI

HEC = 8 x (header octets 1 to 4) / (x 8 + x2 + x + 1)

L2 - 40© P. Raatikainen Switching Technology / 2005

VCI 1

VCI 2

VCI 1

VCI 2VPI 1

VPI 2

Physical channel

VPI 1

VPI 2

VCI 1

VCI 2

VCI 1

VCI 2

ATM connection types

VCI k  - Virtual Channel Identifier k 

VPI k  - Virtual Path Identifierk 

Page 47: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 47/369

L2 - 41© P. Raatikainen Switching Technology / 2005

Physical layers for ATM

• SDH (Synchronous Digital Hierarchy)

 –  STM-1 155 Mbit/s

 –  STM-4 622 Mbit/s

 –  STM-16 2.4 Gbit/s

• PDH (Plesiochronous Digital Hierarchy)

 –  E1 2 Mbit/s

 –  E3 34 Mbit/s

 –  E4 140 Mbit/s

• TAXI 100 Mbit/s and IBM 25 Mbit/s• Cell based interface

 –  uses standard bit rates and physical level interfaces(e.g. E1, STM-1 or STM-4)

 –  HEC used for framing

L2 - 42© P. Raatikainen Switching Technology / 2005

Transport of data in ATM cells

Physical layer 

ATM layer 

ATMadaptationlayer (AAL)

Network layer  IP packet

≤≤≤≤ 65 535

AAL 5 payload PUU/CPI/LEN

CRC

Pad 0 - 47 octets

(1+1+ 2) octets

4 octets

P - Padding octetsUU - AAL layer user-to-user indicator CPI - Common part indicator LEN - Length indicator 

5

H Cell payload H Cell payload H Cell payload H Cell payload

48

Page 48: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 48/369

L2 - 43© P. Raatikainen Switching Technology / 2005

SOH

AU-4 PTR

SOH

9 octets261 octets

3

1

5

STM-1frame

ATM cell

J1

B3

C2

G1

F2

H4Z3

Z4

Z5

...

...

... ...

...

...

VC-4frame

VC-4 POH

ATM cell encapsulation / SDH

L2 - 44© P. Raatikainen Switching Technology / 2005

32 octets

TS0 TS16Header 

TS0 TS16

TS0 TS16 Header 

TS0 TS16Header 

TS0 TS16 Head.

...

TS0

• frame alignment• F3 OAM functions

• loss of frame alignment• performance monitoring• transmission of FERF and LOC

• performance reporting

TS16

• reserved for signaling

ATM cell encapsulation / PDH (E1)

Page 49: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 49/369

L2 - 45© P. Raatikainen Switching Technology / 2005

Cell based interface

Frame structure for cell base interfaces:

IDLE or PL-OAM

PL

ATM layer H H ... ATM layer HIDLE or PL-OAM

PL

ATM layer 

1 2 26 2727

• PL cells processed on physical layer (not on ATM layer)

• IDLE cell for cell rate adaptation

• PL-OAM cells carry physical level OAM information

(regenerator (F1) and transmission path (F3) level messages)

• PL cell identified by a pre-defined header • 00000000 00000000 0000000 00000001 (IDLE cell)

• 00000000 00000000 0000000 00001001 (phys. layer OAM)

• xxxx0000 00000000 0000000 0000xxxx (reserved for phys. layer)

H = ATM cell Header, PL = Physical Layer, OAM = Operation Administration and Maintenance

L2 - 46© P. Raatikainen Switching Technology / 2005

ATM network elements

• Gross-connect

– switching of virtual paths (VPs)

– VP paths are statically connected

• Switch– switching of virtual channel (VCs)

– VC paths are dynamically or statically connected

• DSLAM (Digital Subscriber Line Access Multiplexer)

– concentrates a larger number of sub-scriber lines to a common highercapacity link

– aggregated capacity of subscriber lines surpasses that of the commonlink

Page 50: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 50/369

L2 - 47© P. Raatikainen Switching Technology / 2005

Ethernet

• Originally a link layer protocol for LANs (10 and 100 MbE)

• Upgrade of link speeds=> optical versions 1GbE and 10 GbE=> suggested for long haul transmission

• No connections - each data terminal (DTE) sends datawhen ready - MAC is based on CSMA/CD

• Synchronization – line coding, preamble pattern and start-of-frame delimiter

 – Manchester code for 10 MbE, 8B6T for 100 MbE,8B10B for GbE

L2 - 48© P. Raatikainen Switching Technology / 2005

Ethernet frame

Preamble

S

FD DA SA T/L Payload CRC

7 1 6 6 2 46 - 1500 4

64 - 1518 octets

Preamble - AA AA AA AA AA AA AA (Hex)SFD - Start of Frame Delimiter AB (Hex)DA - Destination AddressSA - Source AddressT/L - Type (RFC894, Ethernet) or Length (RFC1042, IEEE 802.3) indicator CRC - Cyclic Redundance Check

Inter-frame gap 12 octets (9,6 µµµµs /10 MbE)

Page 51: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 51/369

L2 - 49© P. Raatikainen Switching Technology / 2005

1GbE frame

PreambleSFD

DA SA L Payload

7 1 6 6 2 46 - 1500 4

512 - 1518 octets

CRC Extension

Preamble - AA AA AA AA AA AA AA (Hex)

SFD - Start of Frame Delimiter AB (Hex)DA - Destination AddressSA - Source AddressT/L - Type (RFC894, Ethernet) or Length (RFC1042, IEEE 802.3) indicator CRC - Cyclic Redundancy CheckInter-frame gap 12 octets (96 ns /1 GbE)Extension - for padding short frames to be 512 octets long

L2 - 50© P. Raatikainen Switching Technology / 2005

Ethernet network elements

• Repeater 

– interconnects LAN segments on physical layer

– regenerates all signals received from one segment and forwards them ontothe next

• Bridge

– interconnects LAN segments on link layer (MAC)

– all received frames are buffered and error free ones are forwarded to anothersegment (if they are addressed to it)

• Hub and switch

– hub connects DTEs with two twisted pair links in a star topology and repeatsreceived signal from any input to all output links

– switch is an intelligent hub, which learns MAC addresses of DTEs and iscapable of directing received frames only to addressed ports

Page 52: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 52/369

L2 - 51© P. Raatikainen Switching Technology / 2005

Optical transport network

• Optical Transport Network (OTN), being developed by ITU-T(G.709), specifies interfaces for optical networks

• Goal to gather for the transmission needs of today’s widerange of digital services and to assist network evolution tohigher bandwidths and improved network performance

• OTN builds on SDH and introduces some refinements:

 – management of optical channels in optical domain

 – FEC to improve error performance and allow longer link spans

 – provides means to manage optical channels end-to-end in opticaldomain (i.e. no O/E/O conversions)

 – interconnections scale from a single wavelength to multiple ones

L2 - 52© P. Raatikainen Switching Technology / 2005

OTN reference model

- OCh Optical Channel- O A Optical Amplifier  - OMS Optical Multiplexing Section- OMPX Optical Multiplexer - OTS Optical Transport Section

   O  p   t   i  c  a   l

  c   h  a  n  n  e   l  s

OA OA

   O  p   t   i  c  a   l

  c   h  a  n  n  e   l  s

OTSOTS OTS

OMS

OCh

OMPX OMPX

Page 53: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 53/369

L2 - 53© P. Raatikainen Switching Technology / 2005

OTN layers and OCh sub-layers

Optical transport section(OTSn)

Optical multiplexing section(OMSn)

Optical channel

SONET/SDH

ATM Ethernet IP

OTUOptical channel transport unit

ODUOptical channel data unit

OPUOptical channel payload unit

L2 - 54© P. Raatikainen Switching Technology / 2005

OTN frame structure

• Three main fields

– Optical channel overhead

– Payload

– Forward error indication field

Och Payload FEC

Client

Digital wrapper 

FR SONET/SDH ATM GbE IP

DWDM

SONET/SDH

ATM/FR

GbE IP

Page 54: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 54/369

L2 - 55© P. Raatikainen Switching Technology / 2005

OTN frame structure (cont.)

Ochoverhead

Payload FEC   4  r  o  w  s

4080 bytes

1 . .. .. 16 17 . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 3824 3825 . .. 4080

ODU

overhead

Frame alignmt. OTU overhead

OPUoverh.

1 . .... 7 15 ... 168 ..... 14

1

2

34

OTU - Optical transport unitODU - Optical data unitOPU - Optical payload unit

FEC - Forward error correction

• Frame size remains the same (4x4080)regardless of line rate

=> frame rate increases as line rate increases• Three line rates defined:

• OTU1 2.666 Gbit/s• OTU2 10.709 Gbit/s• OTU3 43.014 Gbit/s

L2 - 56© P. Raatikainen Switching Technology / 2005

Generation of OTN frame and signal

+ OPU-OH

OPUClient signal

ODU

+ OTU-OH+ FEC

OTU

OTN frame generation

OChClient signal

OMUX OMS OTS…

OChClient signal

OTN signal generation

Page 55: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 55/369

L2 - 57© P. Raatikainen Switching Technology / 2005

OTN network elements

• optical amplifier 

– amplifies optical line signal

• optical multiplexer 

– multiplexes optical wavelengths to OMS signal

– add-drop multiplexer adds or drops wavelengths to/from a common OMS

• optical cross-connect

– used to direct optical wavelengths (channels) from an OMS to another

– connections set up and released by operator

• optical switches ?– when technology becomes available optical switches will be used for

switching of data packets in the optical domain

L2 - 58© P. Raatikainen Switching Technology / 2005

Generic Framing Procedure (GFP)

• Recently standardized traffic adaptation mechanism especially fortransporting block-coded and packet-oriented data

• Standardized by ITU-T (G.7041) and ANSI (T1.105.02) (the onlystandard supported by both organizations)

• Developed to overcome data transport inefficiencies of existing ATM,POS, etc. technologies

• Operates over byte-synchronous communications channels (e.g.SDH/SONET and OTN)

• Supports both fixed and variable length data frames

• Generalizes error-control-based frame delineation scheme (successfully

employed in ATM)

 – relies on payload length and error control check for frame boundarydelineation

Page 56: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 56/369

L2 - 59© P. Raatikainen Switching Technology / 2005

GFP (cont.)

• Two frame types: client and control frames

 – client frames include client data frames and client management frames

 – control frames used for OAM purposes

• Multiple transport modes (coexistent in the same channel) possible

 – Frame-mapped GFP for packet data, e.g. PPP, IP, MPLS and Ethernet)

 – Transparent-mapped GFP for delay sensitive traffic (storage areanetworks), e.g. Fiber Channel, FICON and ESCON

L2 - 60© P. Raatikainen Switching Technology / 2005

GFP frame types

GFP frames

Clientdata frames

Clientmanagement frames

Idle frames OA&M frames

Client frames Control frames

Page 57: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 57/369

L2 - 61© P. Raatikainen Switching Technology / 2005

GFP client data frame

• Composed of a frame header and payload

• Core header intended for data link management

 – payload length indicator (PLI, 2 octets), HEC (CRC-16, 2 octets)

• Payload field divided into payload header, payload and optional FCS(CRC-32) sub-fields

• Payload header includes:

 – payload type (2 octets) and type HEC (2 octets) sub-fields

 – optional 0 - 60 octets of extension header

• Payload: – variable length (0 - 65 535 octets, including payload header and FCS) for

frame mapping mode (GFP-F) - frame multiplexing

 – fixed size Nx[536, 520] for transparent mapping mode (GFP-T) - no framemultiplexing

L2 - 62© P. Raatikainen Switching Technology / 2005

0 – 60 bytesextension header 

(optional)

Payload FCS

GFP frame structure

Payloadarea

Coreheader 

Core HEC

Payload length indicator 

Payload[N x 536, 520 bytesor variable length

packet]

Payload header 

Type HEC

Payload type UPI

PTI PFI EXI

Extension HEC LSB

Extension HEC MSBSpare

CID

CID - Channel identifierFCS - Frame Check Sequence

EXI - Extension Header Identifier

HEC - Header Error CheckPFI - Payload FCS Indicator

PTI - Payload Type Indicator

UPI - User payload Identifier

Source: IEEE Communications Magazine, May 2002

Page 58: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 58/369

L2 - 63© P. Raatikainen Switching Technology / 2005

GFP relationship to client signals andtransport paths

SDH/SONET path OTN ODUk path

GFPclient-independent

GFPclient-dependent

   E   t   h  e  r  n  e   t

   I   P   /   P   P   P

   M   A   P   O   S

   R   P   R

   F   i   b  e  r

   C   h  a  n  n  e   l

   F   I   C   O   N

   E   S   C   O   N

   O   t   h  e  r

  c   l   i  e  n   t

  s   i  g  n  a   l  s

Framemapped

Transparentmapped

ESCON - Enterprise System CONnection

FICON - Fiber CONnectionIP/PPP - IP over Point-to-Point ProtocolMAPOS - Multiple Access Protocol over SONET/SDH

RPR - Resilient Pack et Ring

Source: IEEE Communications Magazine, May 2002

L2 - 64© P. Raatikainen Switching Technology / 2005

Adapting traffic via GFP-F and GFP-T

FCS - Frame Check SequencecHEC - Core Header Error ControlPDU - Packet Data Unit

PLI - Payload Length Indicator

PLI2 bytes

cHEC2 bytes

Payloadheader 

4 bytes

Client PDU(PPP, IP, Ethernet, RPR, etc.)

FCS(optional)

4 bytes

PLI2 bytes

cHEC2 bytes

Payloadheader 4 bytes

8x64B/65B superblock #1 #2 ... #N-1 #NFCS

(optional)4 bytes

GFP-F frame

GFP-T frame

Page 59: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 59/369

L2 - 65© P. Raatikainen Switching Technology / 2005

GFP-T frame mapping

8B 8B 8B 8B 8B 8B 8B 8B

64B/65B code block

8 x 64B/65B code blocks

Superblock (8 x 64B/65B code blocks + CRC-16)

CRC-16

GFP-T frame with five superblocks

Core header and payload header  FCS (optional)

Page 60: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 60/3691

3 - 1© P. Raatikainen Switching Technology / 2003

Switch Fabrics

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

3 - 2© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Basic concepts

• Time and space switching

• Two stage switches

• Three stage switches

• Cost criteria

• Multi-stage switches and path search

Page 61: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 61/3692 

3 - 3© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Multi-point switching

• Self-routing networks

• Sorting networks

• Fabric implementation technologies

• Fault tolerance and reliability

3 - 4© P. Raatikainen Switching Technology / 2003

Basic concepts

• Accessibility

• Blocking

• Complexity

• Scalability

• Reliability

• Throughput

Page 62: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 62/3693 

3 - 5© P. Raatikainen Switching Technology / 2003

Accessibility

• A network has full accessibility when each inlet canbe connected to each outlet (in case there are noother I/O connections in the network)

• A network has a limited accessibility when theabove given property does not exist

• Interconnection networks applied in today’s switch

fabrics usually have full accessibility

3 - 6© P. Raatikainen Switching Technology / 2003

Blocking

• Blocking is defined as failure to satisfy a connection requirementand it depends strongly on the combinatorial properties of theswitching networks

Blocking Others

Network class Network type Network state

Non-blocking

Withblocking

state

Without blockingstates

Strict-sensenon-blocking

Wide-sensenon-blocking

Rearrangeablynon-blocking

Page 63: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 63/3694 

3 - 7© P. Raatikainen Switching Technology / 2003

Blocking (cont.)

• Non-blocking - a path between an arbitrary idle inlet and arbitrary idleoutlet can always be established independent of network state at set-uptime

• Blocking - a path between an arbitrary idle inlet and arbitrary idle outlet

cannot be established owing to internal congestion due to the alreadyestablished connections

• Strict-sense non-blocking - a path can always be set up between anyidle inlet and any idle outlet without disturbing paths already set up

• Wide-sense non-blocking - a path can be set up between any idleinlet and any idle outlet without disturbing existing connections,provided that certain rules are followed. These rules prevent networkfrom entering a state for which new connections cannot be made

• Rearrangeably non-blocking - when establishing a path between anidle inlet and an idle outlet, paths of existing connections may have to

be changed (rearranged) to set up that connection

3 - 8© P. Raatikainen Switching Technology / 2003

Complexity

• Complexity of an interconnection network is expressed by

cost index

• Traditional definition of cost index gives the number of cross-points in a network

 – used to be a reasonable measure of space division switchingsystems

• Nowadays cost index alone does not characterize cost of aninterconnection network for broadband applications

 – VLSIs and their integration degree has changed the way howcost of a switch fabric is formed (number of ICs, powerconsumption)

 – management and control of a switching system has a significantcontribution to cost

Page 64: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 64/3695 

3 - 9© P. Raatikainen Switching Technology / 2003

Scalability

• Due to constant increase of transport links and data rates onlinks, scalability of a switching system has become a keyparameter in choosing a switch fabric architecture

• Scalability describes ability of a system to evolve with

increasing requirements

• Issues that are usually matter of scalability

 – number of switching nodes

 – number of interconnection links between nodes

 – bandwidth of interconnection links and inlets/outlets – throughput of switch fabric

 – buffering requirements

 – number of inlets/outlets supported by switch fabric

3 - 10© P. Raatikainen Switching Technology / 2003

Reliability

• Reliability and fault tolerance are system measures that have animpact on all functions of a switching system

• Reliability defines probability that a system does not fail within agiven time interval provided that it functions correctly at the start

of the interval• Availability defines probability that a system will function at a

given time instant

• Fault tolerance is the capability of a system to continue itsintended function in spite of having a fault(s)

• Reliability measures:

 – MTTF (Mean Time To Failure)

 – MTTR (Mean Time To Repair)

 – MTB (Mean Time Between Failures)

Page 65: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 65/3696 

3 - 11© P. Raatikainen Switching Technology / 2003

Throughput

• Throughput gives forwarding/switching speed/efficiency of aswitch fabric

• It is measured in bits/s, octets/s, cells/s, packet/s, etc.

• Quite often throughput is given in the range (0 ... 1.0], i.e. theobtained forwarding speed is normalized to the theoreticalmaximum throughput

3 - 12© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Basic concepts

• Time and space switching

• Two stage switches

• Three stage switches

• Cost criteria

• Multi-stage switches and path search

Page 66: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 66/3697 

3 - 13© P. Raatikainen Switching Technology / 2003

Switching mechanisms

• A switched connection requires a mechanism thatattaches the right information streams to each other

• Switching takes place in the switching fabric, thestructure of which depends on network’s mode ofoperation, available technology and required capacity

• Communicating terminals may use different physicallinks and different time-slots, so there is an obvious

need to switch both in time and in space domain

• Time and space switching are basic functions of aswitch fabric

3 - 14© P. Raatikainen Switching Technology / 2003

Space division switching

1

2

3

4

5

6

7

8

1

2

3

4

5

6

INPUTSOUTPUTS

m   INPUT LINKS   n   OUTPUT LINKSINTERCONNECTIONNETWORK

• A space switch directs traffic from input links to output links• An input may set up one connection (1, 3, 6 and 7), multiple

connections (4) or no connection (2, 5 and 8)

Page 67: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 67/3698 

3 - 15© P. Raatikainen Switching Technology / 2003

Crossbar switch matrix

• Crossbar matrix introduces the basic structure of a space switch• Information flows are controlled (switched) by opening and closing

cross-points

• m   inputs and n   outputs =>   mn  cross-points (connection points)• Only one input can be connected to an output at a time, but an input

can be connected to multiple outputs (multi-cast) at a time

1234

5678

1 2 3 4 5 6

    m

   I   N   P   U   T   L   I   N   K   S

n   OUTPUT LINKS

MULTI-CAST

A CLOSED CROSS-POINT

3 - 16© P. Raatikainen Switching Technology / 2003

An example space switch

• m  x1 -multiplexer used to implement a space switch• Every input is fed to every output mux and mux control signals

are used to select which input signal is connected througheach mux

mx1

12

1 2   m 

mx1 mx1

mux/connection control

Page 68: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 68/3699 

3 - 17© P. Raatikainen Switching Technology / 2003

Time division multiplexing

• Time-slot interchanger is a device, which buffers m  incoming time-

slots, e.g. 30 time-slots of an E1 frame, arranges new transmit

order and transmits n  time-slots

• Time-slots are stored in buffer memory usually in the order they

arrive or in the order they leave the switch - additional control logic

is needed to decide respective output order or the memory slot

where an input slot is stored

INPUT CHANNELS OUTPUT CHANNELS

123456

Time-slot 1

Time-slot 2

Time-slot 3

Time-slot 4

Time-slot 5

Time-slot 6

1 23 45 6

TIME-SLOT INTERCHANGER

BUFFER SPACE FOR TIME-SLOTS

3 - 18© P. Raatikainen Switching Technology / 2003

Time-slot interchange

12345678 123456

1

2

3

4

5

6

7

8

BUFFER FOR m 

INPUT/OUTPUT SLOTS

    m

   I   N   P   U   T   L   I   N   K   S

    n   O   U   T   P   U   T   L   I   N   K   S(3) (2) (4) (1,6) (5)

DESTINATION OUTPUT #

Page 69: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 69/36910 

3 - 19© P. Raatikainen Switching Technology / 2003

Time switch implementation example 1

• Incoming time-slots are written cyclically into switch memory• Output logic reads cyclically control memory, which contains a pointer for

each output time-slot• Pointer indicates which input time-slot to insert into each output time-slot

1

2

3

...

Time-slot counter & R/W control

...k

m

Switchmemory

1

2

3

n

Controlmemory

...

..

. j (k)

123m …

Incoming frame buffer 

12 jn … …

Outgoing frame buffer 

readaddress (k)

Cyclic read

  w  r   i   t  e

  a   d   d  r  e  s  s   (   3   )

Cyclic write

  r  e  a   d   /  w  r   i   t  e

  a   d   d  r  e  s  s   (   j   )

3 - 20© P. Raatikainen Switching Technology / 2003

Time switch implementation example 2

• Incoming time-slots are written into switch memory by using write-addressesread from control memory

• A write address points to an output slot to which the input slot is addressed• Output time-slots are read cyclically from switch memory

1

2

3

...

Time-slot counter & R/W control

...k

n

Switchmemory

1

2

3 (k)

m

Controlmemory

...

123m …Incoming frame buffer 

12 jn … …Outgoing frame buffer 

writeaddress (k)

Cyclic read

  r  e  a   d

  a   d   d  r  e  s  s   (   3   )

Cyclic write

  r  e  a   d   /  w  r   i   t  e

  a   d   d  r  e  s  s   (   2   )

Page 70: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 70/36911

3 - 21© P. Raatikainen Switching Technology / 2003

Properties of time switches

• Input and output frame buffers are read and written at wire-speed,i.e. m  R/Ws for input and n  R/Ws for output

• Interchange buffer (switch memory) serves all inputs and outputsand thus it is read and written at the aggregate speed of all inputsand outputs=> speed of an interchange buffer is a critical parameter in timeswitches and limits performance of a switch

• Utilizing parallel to serial conversion memory speed requirement

can be cut• Speed requirement of control memory is half of that of switchmemory (in fact a little moor than that to allow new control data tobe updated)

3 - 22© P. Raatikainen Switching Technology / 2003

Time-Space analogy

• A time switch can be logically converted into a space switch bysetting time-slot buffers into vertical position => time-slots can beconsidered to correspond to input/output links of a space switch

• But is this logical conversion fair ?

123m … 123n …

 …

1

2

3

m

 …

1

2

3

m

Time switch

Space switch

Page 71: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 71/36912 

3 - 23© P. Raatikainen Switching Technology / 2003

Space-Space analogy

• A space switch carrying time multiplexed input and output signals can be

logically converted into a pure space switch (without cyclic control) by

distributing each time-slot into its own space switch

Inputs and outputs aretime multiplexed signals

(K time-slots)

 …

1

2

m

 …

1

2

n

1 …

1

2

m …

1

2

n

2 …

1

2

m

 …

1

2

n

K …

1

2

m …

1

2

n

To switch a time-slot, it is enough

to control one of the K boxes

3 - 24© P. Raatikainen Switching Technology / 2003

An example conversion

n   K  m  u   l   t   i  p   l  e  x  e   d

   i  n  p  u   t  s   i  g  n  a   l  s

  o  n  e  a  c   h   l   i  n   k

2

112

 m

12

 m

1

2

K

1

2

n

mxn KxK

1

2

K

nxm

12

m

12

m

12

m

12

m

12

m

12

m

… 

… 

… 

Page 72: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 72/36913 

3 - 25© P. Raatikainen Switching Technology / 2003

Properties of space and time switches

• number of cross-points (e.g.AND-gates)- m  input x n  output = mn 

- when m =n  => n 2

• output bit rate determines thespeed requirement for theswitch components

• both input and output linesdeploy “bus” structure=> fault location difficult

• size of switch memory (SM)and control memory (CM)grows linearly as long as

memory speed is sufficient, i.e.- SM = 2 x number of time-slots- CM = 2 x number of time-slots

• a simple and cost effectivestructure when memory speedis sufficient

• speed of available memorydetermines the maximumswitching capacity

Space switches Time switches

3 - 26© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Basic concepts

• Time and space switching

• Two stage switches

• Three stage switches

• Cost criteria

• Multi-stage switches and path search

Page 73: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 73/36914 

3 - 27© P. Raatikainen Switching Technology / 2003

A switch fabric as a combination of space and time switches

• Two stage switches• Time-Time (TT) switch• Time-Space (TS) switch

• Space-Time (SP) switch• Space-Apace (SS) switch

• TT-switch gives no advantage compared to a single

stage T-switch• SS-switch increases blocking probability

3 - 28© P. Raatikainen Switching Technology / 2003

A switch fabric as a combination of space and time switches (cont.)

• ST-switch gives high blocking probability (S-switch candevelop blocking on an arbitrary bus, e.g. slots from twodifferent buses attempting to flow to a common output)

• TS-switch has low blocking probability, because T-switchallows rearrangement of time-slots so that S-switching canbe done blocking free

12

n

12

n

… 

TS n

TS 1

TS 2

… 

TS n

TS 1

TS 2

  …

… 

TS n

TS 1

TS 2 12

n

12

n

… 

TS n

TS 1

TS 2

… 

TS n

TS 1

TS 2

  …

… 

TS n

TS 1

TS 2

ST-switch TS-switch

Page 74: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 74/36915 

3 - 29© P. Raatikainen Switching Technology / 2003

Time multiplexed space (TMS) switch

• Space divided inputs and each of themcarry a frame of three time-slots

• Input frames on each link aresynchronized to the crossbar

• A switching plane for each

time-slot to direct incomingslots to destined outputlinks of thecorrespondingtime-slot

Cross-point closed

1 2 3 4

Ti

me

  S  p  a  c

  e

4x4 plane for slot 1

4x4 plane for slot 2

4x4 plane for slot 3

1

2

3

4

1

2

3

4

1

2

3

4

  I n c o m

  i n g   f r a m

 e s

Outputs

TS3 TS2 TS1

Output link address

4 1

2 3 2

3 2 1

1 4

3 - 30© P. Raatikainen Switching Technology / 2003

Connection conflicts in a TMS switch

• Space divided inputs and each of themcarry a frame of three time-slots

• Input frames on each link are

synchronized to the crossbar• A switching plane for each

time-slot to direct incomingslots to destined outputlinks of thecorrespondingtime-slot

Cross-point closed

1 2 3 4

Ti

me

  S  p  a  c

  e

4x4 plane for slot 1

4x4 plane for slot 2

4x4 plane for slot 3

1

2

3

4

1

2

3

4

1

2

3

4

  I n c o m

  i n g   f r a m

 e s

Outputs

TS3 TS2 TS1

4 1 4

2 3 2

3 2 1

1 4

Connectionconflict

Conflict solvedby time-slotinterchange

Page 75: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 75/36916 

3 - 31© P. Raatikainen Switching Technology / 2003

TS switch interconnecting TDM links

1

2

3

TIME

3x3 TSI

OUTPUTS OF 4x4 TMS

SPACE

   P   L  A   N   E    F   O

   R    S   L   O

   T    2

   P   L  A   N   E    F   O

   R    S   L   O

   T    3

   P   L  A

   N   E

    F   O   R

    S   L   O

   T   1

• Time division switchingapplied prior to space

switching

• Incoming time-slots can

always be rearranged such

that output requests become

conflict free for each slot of

a frame, provided that thenumber of requests for each

output is no more than the

number of slots in a frame

3 - 32© P. Raatikainen Switching Technology / 2003

SS equivalent of a TS-switch

3 PLANES

3x3S-SWITCHPLANES

4 PLANES

4x4S-SWITCHPLANES

   3   I   N   P   U   T   S

  4    O   U   T   P

   U   T   S

Page 76: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 76/36917 

3 - 33© P. Raatikainen Switching Technology / 2003

Connections through SS-switch

Coordinate (X, Y, Z)

stageplaneinput/output port

Example connections:- (1, 3, 1) => (2, 1, 2)- (1, 4, 2) => (2, 3, 4)

3x3S-SWITCHPLANES

4 PLANES

4x4S-SWITCHPLANES

(1, 3, 1)

(2, 1, 2)

(1, 4, 2)

(2, 3, 4)

3 - 34© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Basic concepts

• Time and space switching

• Two stage switches

• Three stage switches

• Cost criteria

• Multi-stage switches and path search

Page 77: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 77/36918 

3 - 35© P. Raatikainen Switching Technology / 2003

Three stage switches

• Basic TS-switch sufficient for switching time-slots onto addressedoutputs, but slots can appear in any order in the output frame

• If a specific input slot is to carry data of a specific output slot then atime-slot interchanger is needed at each output=> any time-slot on any input can be connected to any time-slot on any output=> blocking probability minimized

• Such a 3-stage configuration is named TST-switching(equivalent to 3-stage SSS-switching)

… 

TS n

TS 1

TS 2

… 

TS n

TS 1

TS 2

  …

… 

TS n

TS 1

TS 21

2

n

… 

TS n

TS 1

TS 2

… 

TS n

TS 1

TS 2

  …

… 

TS n

TS 1

TS 2 1

2

n

TST-switch:

3 - 36© P. Raatikainen Switching Technology / 2003

SSS presentation of TST-switch

INPUTS

3x3T- or S-SWITCH

PLANES

4 PLANES

4x4S-SWITCHPLANES

3x3T- or S-SWITCH

PLANES

OUTPUTS3 HORIZONTALPLANES

4 PLANES

Page 78: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 78/36919 

3 - 37© P. Raatikainen Switching Technology / 2003

Three stage switch combinations

• Possible three stage switch combinations:• Time-Time-Time (TTT) ( not significant, no connection from

PCM to PCM)• Time-Time-Space (TTS) (=TS)

• Time-Space-Time (TST)• Time-Space-Space (TSS)• Space-Time-Time (STT) (=ST)• Space-Time-Space (STS)

• Space-Space-Time (SST) (=ST)• Space-Space-Space (SSS) (not significant, high probabilityof blocking)

• Three interesting combinations TST, TSS and STS

3 - 38© P. Raatikainen Switching Technology / 2003

Time-Space-Space switch

• Time-Space-Space switch can be applied to increase switchingcapacity

… 

TS n

TS 1

TS 2

… 

TS n

TS 1

TS 2

  …

… 

TS n

TS 1

TS 21

2

n

1

2

n

… 

TS n

TS 1

TS 2

… 

TS n

TS 1

TS 2

  …

… 

TS n

TS 1

TS 212

n

12

n

Page 79: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 79/36920 

3 - 39© P. Raatikainen Switching Technology / 2003

Space-Time-Space switch

• Space-Time-Space switch has a high blocking probability (likeST-switch) - not a desired feature in public networks

1

2

n

1

2

n

… 

TS n

TS 1

TS 2

… 

TS n

TS 1

TS 2

  …

… 

TS n

TS 1

TS 2

3 - 40© P. Raatikainen Switching Technology / 2003

Graph presentation of space switch

• A space division switch can be presented by a graph G  = (V , E )

- V  is the set of switching nodes

- E  is the set of edges in the graph

• An edge e ∈E  is an ordered pair (u ,v ) ∈V 

- more than one edge can exist between u  and v 

- edges can be consider to be bi-directional

• V  includes two special sets ( T  and R  ) of nodes not considered

part of switching network

- T  is a set of transmitting nodes having only outgoing edges

(input nodes to switch)

- R  is a set of receiving node having only incoming edges (output

nodes from switch)

Page 80: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 80/36921

3 - 41© P. Raatikainen Switching Technology / 2003

Graph presentation of spaceswitch (cont.)

• A connection requirement is specified for each t ∈T  by subset R t ∈R 

to which t  must be connected

- subsets R t  are disjoint for different t 

- in case of multi-cast R t  contains more than one element for each t 

• A path is a sequence of edges (t ,a ), (a ,b ), (b ,c ), … ,(f ,g ), (g ,r ) ∈E ,

t ∈T , r ∈R  and a,b,c,…,f,g are distinct elements of V - (T+R )

• Paths originating from different t  may not use the same edge• Paths originating from the same t  may use the same edges

3 - 42© P. Raatikainen Switching Technology / 2003

Graph presentation example

INPUT NODES t  OUTPUT NODES r 

t 1

t 2 t 3 

t 15 

.

.

.

r 1

r 2 r 3 

r 15 

.

.

.

s 1

s 2 

s 5 

v 1

v 2 

v 5 

u 1

u 2 

u 3 

v 3 

v 4 

s 3 

s 4 

V  = (t 1, t 2 ,... t 15 , s 1, s 2 ,... s 5 , u 1, u 2 , u 3 , v 1, v 2 ,... v 5 , r 1, r 2 ,... r 15 )

E  = {(t 1, s 1), ...(t 15 , s 5 ), (s 1, u 1), (s 1, u 2 ) ,... (s 5 , u 3 ), (u 1, v 1 ), (u 1, v 2 ), ... (u 3 , v 5 ),

(v 1, r 1 ), (v 1, r 2 ),... (v 5 , r 15 )}

Page 81: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 81/36922 

3 - 43© P. Raatikainen Switching Technology / 2003

SSS-switch and its graph presentation

INPUTS

3x3S-SWITCHPLANES

5PLANE

S

5x5S-SWITCHPLANES

3x3S-SWITCHPLANES

OUTPUTS3 HORIZONTAL PLANES

5PLANES

INPUTS t  OUTPUTS r 

3 - 44© P. Raatikainen Switching Technology / 2003

Graph presentation of connections

INPUTS t  OUTPUTS r 

A PATH

A TREE

Page 82: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 82/3691

4 - 1© P. Raatikainen Switching Technology / 2003

Switch Fabrics

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

4 - 2© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Basic concepts

• Time and space switching

• Two stage switches

• Three stage switches

• Cost criteria

• Multi-stage switches and path search

Page 83: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 83/3692 

4 - 3© P. Raatikainen Switching Technology / 2003

Cost criteria for switch fabrics

• Number of cross-points

• Fan-out

• Logical depth

• Blocking probability

• Complexity of switch control

• Total number of connection states• Path search

4 - 4© P. Raatikainen Switching Technology / 2003

Cross-points

• Number of cross-points gives the number of on-off gates(usually “and-gates”) in space switching equivalent of a fabric

• minimization of cross-point count is essential when cross-pointtechnology is expensive (e.g. electro-mechanical and optical

cross-points)• Very Large Scale Integration (VLSI) technology implements

cross-point complexity in Integrated Circuits (ICs)=> more relevant to minimize number of ICs than number ofcross-points

• Due to increasing switching speeds, large fabric constructionsand increased integration density of ICs, power consumption hasbecome a crucial design criteria- higher speed => more power- large fabrics => long buses, fan-out problem and more driving power- increased integration degree of ICs => heating problem

Page 84: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 84/3693 

4 - 5© P. Raatikainen Switching Technology / 2003

Fan-out and logical depth

• VLSI chips can hide cross-point complexity, but introducepin count and fan-out problem

• length of interconnections between ICs can be long loweringswitching speed and increasing power consumption

• parallel processing of switched signals may be limited by thenumber  of available pins of ICs

• fan-out gives the driving capacity of a switching gate, i.e. numberof inputs (gates/cross-points) that can be connected to an output

• long buses connecting cross-points may lower the number of gatesthat can be connected to a bus

• Logical depth gives the number of cross-points a signaltraverses on its way through a switch

• large logical depth causes excessive delay and signal deterioration

4 - 6© P. Raatikainen Switching Technology / 2003

Blocking probability

• Blocking probability of a multi-stage switching networkdifficult to determine

• Lee’s approximation gives a coarse measure of blocking

• Assume uniformly distributed load• equal load in each input

• load distributed uniformly amongintermediate stages (and theiroutputs) and among outputsof the switch

• Probability that an input isengaged is   a = λ S  where- λ  = input rate on an input link

- S  = average holding time of a link

kxn

nxk

2

1

...

k

1

n

1

n

Page 85: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 85/3694 

4 - 7© P. Raatikainen Switching Technology / 2003

Blocking probability (cont.)

• Under the assumption of uniformly distributed load,probability that a path between any two switching blocksis engaged is  p = an /  k ( k≥ n)

• Probability that a certain path from an input block to anoutput block is engaged is 1 - (1- p) 2  where the last term isthe probability that both (input and output) links aredisengaged

• Probability that all  k paths between an input switchingblock and an output switching block are engaged is

  B = [1 - (1-  an /  k  ) 2 ] k

which is known as Lee’s approximation

4 - 8© P. Raatikainen Switching Technology / 2003

Control complexity

• Give a graph G  , a control algorithm is needed to find and set uppaths in G  to fulfill connection requirements

• Control complexity is defined by the hardware (computation andmemory) requirements and the run time of the algorithm

• Amount of computation depends on blocking category and degree ofblocking tolerated

• In general, computation complexity grows exponentially as a functionof the number of terminal

• There are interconnection networks that have a regular structure forwhich control complexity is substantially reduced

• There are also structures that can be distributed over a large numberof control units

Page 86: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 86/3695 

4 - 9© P. Raatikainen Switching Technology / 2003

Management complexity

• Network management involves adaptation and maintenance of aswitching network after the switching system has been put in place

• Network management deals with

• failure events and growth in connectivity demand

• changes of traffic patterns from day to day

• overload situations

• diagnosis of hardware failures in switching system, control systemas well as in access and trunk network- in case of failure, traffic is rerouted through redundant built-in

hardware or via other switching facilities- diagnosis and failure maintenance constitute a significant part ofsoftware of a switching system

• In order for switching cost to grow linearly in respect to total traffic,switching functions (such as control, maintenance, call processing andinterconnection network) should be as modular as possible

4 - 10© P. Raatikainen Switching Technology / 2003

Example 1

• A switch with

• a capacity of N  simultaneous calls

• average occupancy on lines during busy hour is X   Erlangs

• Y  % requirement for internal use

• notice that two (one-way) connections are needed for a call

requires a switch fabric with M  = 2 x [(100+Y )/100] x(N  / X ) inputsand outputs.

• If N  = 20 000, X  = 0.72 and Y  = 10%

=> M  = 2 x 1.1 x 20 000/0.72 = 61 112

=> corresponds to 2038 E1 links 12

M

12

M

Page 87: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 87/3696 

4 - 11© P. Raatikainen Switching Technology / 2003

Amount of traffic in Erlangs

• Erlang defines the amount of traffic flowing through acommunication system - it is given as the aggregate holding time ofall channels of a system divided by the observation time period

• Example 1:- During an hour period three calls are made (5 min, 15 min and 10min) using a single telephone channel => the amount of trafficcarried by this channel is (30 min/60 min) = 0.5 Erlang

• Example 2:

- a telephone exchange supports 1000 channels and during a busyhour (10.00 - 11.00) each channel is occupied 45 minutes on theaverage => the amount of traffic carried through the switch duringthe busy hour is (1000x45 min / 60 min) = 75 Erlangs

4 - 12© P. Raatikainen Switching Technology / 2003

Erlang’s first formula

• Erlang 1st formula applies to systems fulfilling conditions- a failed call is disconnected (loss system)- full accessibility- time between subsequent calls vary randomly- large number of sources

•    E 1(5, 2.7) implies that we have a system of 5 inlets and offered

load is 2.7 Erlangs - blocking calculated using the formula is 8.5 %

• Tables and diagrams (based on Erlang’s formula) have beenproduced to simplify blocking calculations

( ) E n A

 A

 n

 A  A A

 n

 n

 n1   2

12

,   !

! !

=

+ + + + 

Erlang 1st formula

Page 88: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 88/3697 

4 - 13© P. Raatikainen Switching Technology / 2003

Example 2

• An exchange for 2000 subscribers is to be installed and it isrequired that the blocking probability should be below 10 %.If E2 links are used to carry the subscriber traffic totelephone network, how many E2 links are needed ?- average call lasts 6 min- a subscriber places one call during a 2-hour busy period(on the average)

• Amount of offered traffic is (2000x6 min /2x60 min) = 100 Erl.

• Erlang 1st formula gives for 10 % blocking and load of 100 Erl.that n  = 97

=> required number of E1 links is ceil(97/30) = 4

4 - 14© P. Raatikainen Switching Technology / 2003

Example 3

• Suppose driving current of a switching gate (cross-point) is 100 mAand its maximum input current is 8 mA

• How many output gates can be connected to a bus, driven by oneinput gate, if the capacitive load of the bus is negligibly small ?

• Fan-out = floor[100/8] = 12 c

c c c

1

2 M

• How many output gates can be connectedto a bus driven by one input gate if load ofthe bus corresponds to 15 % of the load ofa gate input) ?

• Fan-out = floor[100/(1.15x8)] = 10

Page 89: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 89/3698 

4 - 15© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Basic concepts

• Time and space switching

• Two stage switches

• Three stage switches

• Cost criteria• Multi-stage switches and path search

4 - 16© P. Raatikainen Switching Technology / 2003

Multi-stage switching

• Large switch fabrics could be constructed by using asingle N xN  crossbar, interconnecting N  inputs to N 

outputs- such an array would require N 2  cross-points

- logical depth = 1- considering the limited driving power of electronic or opticalswitching gates, large N  means problems with signal quality (e.g.delay, deterioration)

• Multi-stage structures can be used to avoid aboveproblems

• Major design problems with multi-stages- find a non-blocking structure- find non-conflicting paths through the switching network

Page 90: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 90/3699 

4 - 17© P. Raatikainen Switching Technology / 2003

Multi-stage switching (cont.)

• Let’s take a network of K  stages

• Stage k  (1≤k ≤K ) has r k  switch blocks (SB)

• Switch block  j  (1≤ j ≤ r k ) in stage k  is denoted by S ( j ,k )

• Switch  j  has m k  inputs and n k  outputs

• Input i  of S ( j ,k ) is represented by e (i,j ,k )

• Output i  of S ( j ,k ) is represented by o (i,j ,k )

• Relation o (i,j ,k )= e (i’,j’ ,k+1) gives interconnection between output i 

and input i’  of switch blocks  j  and  j’  in consecutive stages k  and k +1• Special class of switches:

•   n k  = r k+1 and m k  = r k-1• each SB in each stage connected to each SB in the next stage

4 - 18© P. Raatikainen Switching Technology / 2003

Clos network

• parameterm 

1,n 

3,r 1,

r 2,

r 3

chosen freely

• other parameters determined

uniquely by n 1 = r 2, m 2 = r 1,

n 2 = r 3, m 3 = r 2

m k = number of inputs in a SB at stage k 

n k = number of outputs in a SB at stage k 

r k  = number of SBs at stage k 

SB = Switch Block

m 1 = 3

n 1 = r 2 = 5

m 2 = r 1 = 3 n 2 = r 3 = 4m 3 = r 2 = 5

r 1 = 3

r 3 = 4r 2 = 5

n 3 = 2

Page 91: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 91/36910 

4 - 19© P. Raatikainen Switching Technology / 2003

Graph presentation of a Clos network

n 3 = 2

r 1 = 3

r 2 = 5

r 3 = 4

n 1 = r 2 = 5

m 2 = r 1 = 3   n 2 = r 3 = 4m 3 = r 2 = 5

m 1 = 3

Every SB in stage k  is connected to all r k+1 SBs in the followingstage k +1 with a single link.

1234

1234

4x4 switch

4 - 20© P. Raatikainen Switching Technology / 2003

Path connections in a 3-stage network

1ST STAGESBs

SB a 

2ND STAGESBs

3RD STAGESBs

SB b 

SB c 

SB x  SB y 

• An input of SB x  may be connected to an output of SB y  via amiddle stage SB a 

• Other inputs of SB x  may be connected to other outputs of SB y via other middle stage SBs (b , c , …)

• Paull’s connection matrix is usedto represent paths in threestage switches

Page 92: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 92/36911

4 - 21© P. Raatikainen Switching Technology / 2003

Paull’s matrix

a, b, c

r 3y 1 2 . . . . . .

1

2.

..

r 1

.

.

.

   S   t  a  g  e   1  s  w   i   t  c   h

   b   l  o  c   k  s

Stage 3 switch blocks

• Middle stage switch blocks (a , b , c ) connecting 1st stage SB x  to3rd stage SB y  are entered into entry (x ,y ) in r 

1 x r 

3  matrix

• Each entry of the matrix may have 0, 1 or several middle stage SBs

• A symbol (a ,b ,..) appears as many times in the matrix as there areconnections through it

4 - 22© P. Raatikainen Switching Technology / 2003

Paull’s matrix (cont.)

Conditions for a legitimate point-to-point connectionmatrix:

1 Each row has at most m 1 symbols, since there can be as many

paths through a 1st stage SB as there are inputs to it

Columns

At most min(m 1, r 2) symbols in row  x 

r 3y 1 2 . . . . . .

1

2...

r 1

.

.

.

At most min(n 3, r 2) distinct symbols inrow y 

   R  o  w  s

2 Each column has at most n 3  symbols, since there can be as

many paths through a 3rd stage SB as there are outputs from it

Page 93: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 93/36912 

4 - 23© P. Raatikainen Switching Technology / 2003

Paull’s matrix (cont.)

Conditions of a legitimate point-to-point connectionmatrix (cont.):

In case of multi-casting, conditions 1 and 3 may not be valid,because a path from the 1st stage may be directed via several2nd stage switch blocks. Conditions 2 and 4 remain valid.

3 Symbols in each row must be distinct, since only one edgeconnects a 1st stage SB to a 2nd stage SB

=> there can be at most r 2 different symbols

4 Symbols in each column must be distinct, since only one edgeconnects a 2nd stage SB to a 3rd stage SB and an edge doesnot carry signals from several inputs

 => there can be at most r 2 different symbols

4 - 24© P. Raatikainen Switching Technology / 2003

Strict-sense non-blocking Clos

A network is strict sense non-blocking if any t ∈T- T’  can establisha legitimate multi-cast tree to any subset R  - R’  without changes tothe previously established paths.

A rearrangeable network satisfies the same conditions, but allowschanges to be made to the previously established paths.

• T’  is a subset of set T  of transmitting terminals

• R’  is a subset of set R  of receiving terminals

• Each element of T’  is connected by a legitimate multi-cast tree toa non-empty and disjoint subset R’ 

• Each element of R’  is connected to one element of T’ 

Definitions:

Page 94: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 94/36913 

4 - 25© P. Raatikainen Switching Technology / 2003

Clos theorem

A Clos network is strict-sense non-blocking if and only if thenumber of 2nd stage switch blocks fulfills the condition

r 2  ≥ m 1 + n 3  - 1

r 2  ≥ 2n  - 1

Clos theorem:

• A symmetric Clos network with m 1 = n 3  = n  is strict-sense non-blocking if

4 - 26© P. Raatikainen Switching Technology / 2003

Proof of Clos theorem

• Let’s take some SB x   in the 1st stage and some SB y  in the 3rdstage, which both have maximum number of connection minus one.

=> x  hasm 

1 -1 and y  hasn 3 -1 connections

• One additional connection should be established between x  and y 

• In the worst case, existing connections of x  and y  occupy distinct2nd stage SBs

=> m 1 -1 SBs for paths of x  has and n 3 -1 SBs for paths of y 

• To have a connection between x  and y  an additional SB is neededin the 2nd stage

=> required number of SBs is (m 1 -1) + (n 3 -1) + 1 = m 1 + n 3 -1

Proof 1:

Page 95: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 95/36914 

4 - 27© P. Raatikainen Switching Technology / 2003

Visualization of proof 

m1-1

2

1

...

n3-1

2

1

...

1

n1

1

m3

4 - 28© P. Raatikainen Switching Technology / 2003

Paull’s matrix and proof of Clos theorem

• A connection from an idle input of a 1st stage SB x  to an idleoutput of a 3rd stage SB y  should be established

•  m 1-1 symbols can exist already in row x , because there are m 1inputs to SB x .

•  n 3 -1 symbols can exist already in row y , because there are n 

outputs to SB y .

• In the worst case, all the (m 1-1 + n 

3 -1) symbol are distinct

• To have an additional path between x  and y , one more SB isneeded in the 2nd stage

=> m 1 + n 3 -1 SBs are needed

Proof 2:

Page 96: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 96/36915 

4 - 29© P. Raatikainen Switching Technology / 2003

Procedure for making connections

• Keep track of symbols used by row x  using an occupancy vector u x (which has r 2  entries that represent SBs of the 2nd stage)

• Enter “1” for a symbol in u x if it has been used in row x , otherwiseenter “0”

• Likewise keep track of symbols used by column y  using anoccupancy vector u y 

• To set up a connection between SB x  and SB y  look for a position j in u x  and u y  which has “0” in both vectors

• Amount of required computationis proportional to r 2    u x  0 1 1 0 0 1

1 2 3 j   r 2

1 1 0 0 1 0

1 2 3 j   r 2

u y 

common “0”

4 - 30© P. Raatikainen Switching Technology / 2003

Rearrangeable networks

A three stage network is rearrangeable if and only if

r 2  ≥ max(m 1, n 3 )

Slepian-Duguid theorem:

A symmetric Clos network with m 1 = n 

3  = n  is rearrangeably non-

blocking ifr 2  ≥ n 

Paull’s theorem:

The number of circuits that need to be rearranged is at most

min(r 1, r 

3 ) -1

Page 97: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 97/36916 

4 - 31© P. Raatikainen Switching Technology / 2003

Connection rearrangement byPaull’s matrix

• If there is no common symbol (position  j ) found in u x  and u y , we lookfor symbols in u x  that are not in u y   and symbols in u y  not found in u x 

=> a new connection can be set up only by rearrangement

• Let’s suppose there is symbol a  in u x  (not in u y ) and symbol b  in u y 

(not in u x ) and let’s choose either one as a starting point

• Let it be a   then b  is searched from the column in which a  resides (inrow x ) - let it be column j 1 in which b  is found in row i 1

• In row i 1 search for a  - let this position be column j 2  n

• This procedure continues until symbol a  or b  cannot be found in thecolumn or row visited

1 1 0 1 1

1 2 b   r 2

u y  1

a

u x  1 1 0 1 1

1 2 a   r 2

1

b

4 - 32© P. Raatikainen Switching Technology / 2003

Connection rearrangement by Paull’smatrix (cont.)

• At this point connections identified can be rearranged by replacingsymbol a  (in rows x , i 1, i 2 , ...) by b  and symbol b  (in columns y , j 1, j 2 , ...) by a 

•  a  and b  still appear at most once in any row or column

2nd stage SB a  can be used to connect x  and y r 3

1 j1

1

r 1

y j3  j2

i1

x

i2   a 

b    a 

r 31 j1

1

r 1

y j3  j2

i1

x

i2

a b 

Page 98: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 98/36917 

4 - 33© P. Raatikainen Switching Technology / 2003

Example of connection rearrangementby Paull’s matrix

• Let’s take a three-stage network 24x25 with r 1=4 and r 

3 =5

• Rearrangeability condition requires that r 2 =6

- let these SBs be marked by a , b , c , d , e   and f 

=> m 1 = 6, n 

1 = 6, m 

2  = 4, n 

2  = 5, m 

3  = 6, n 

3  = 5

1

2

4

1(a )

2(b )

6(f )

6x6 4x5

1

2

5

6x5

12

6

1

26

12

6

12

5

1

25

12

5

… 

… 

… 

4 - 34© P. Raatikainen Switching Technology / 2003

Example of connection rearrangementby Paull’s matrix (cont.)

   1  s   t  s   t  a  g  e   S   B  s

1 2

1

2

3

4

3 4 5

3rd stage SBs

f a b,e c  

a,b 

e,f 

b,f d c 

• In the network state shown below, a new connection is to beestablished between SB1 of stage 1 and SB1 of stage 3

• No SBs available in stage 2 to allow a new connection

• Slepian-Duguid theorem => a three stage network is rearrangeable

if and only if r 2  ≥ max(m 1, n 3 )- m 1 = 6, n 3  = 5, r 2  = 6 => condition fulfilled

• SBs c  and d  are selected to operate rearrangement

u 1-1

u 3-1

1 1 1 10

a b c

1

d e f 

1 1 0 01

a b c

0

d e f 

Occupancy vectors of SB1/stage 1and SB1/stage 3

Page 99: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 99/36918 

4 - 35© P. Raatikainen Switching Technology / 2003

Example of connection rearrangementby Paull’s matrix (cont.)

   1  s   t  s   t  a  g  e   S   B  s

1 2

1

2

3

4

3 4 5

3rd stage SBs

c,f a b,e    d 

a,b 

e,f 

b,f d c 

• Start rearrangement procedure from symbol c  in row 1 andcolumn 5

• 5 connection rearrangements are needed to set up the requiredconnection - Paull’s theorem !!!

   1  s   t  s   t  a  g  e   S   B  s

1 2

1

2

3

4

3 4 5

3rd stage SBs

f a b,e c  

a,b 

e,f 

b,f d c 

4 - 36© P. Raatikainen Switching Technology / 2003

Example of connection rearrangementby Paull’s matrix (cont.)

   1  s   t  s   t  a  g  e   S   B  s

1 2

1

2

3

4

3 4 5

3rd stage SBs

f a b,e c  

a,b 

e,f 

b,f d c 

   1  s   t  s   t  a  g  e   S   B  s

1 2

1

2

3

4

3 4 5

3rd stage SBs

c ,f a b,e d  

a,b 

e,f 

b,f c d 

• Paull’s theorem states that the number of circuits that need to berearranged is at most min(r 

1, r 

3 ) -1 = 3

=> there must be another solution

• Start rearrangement procedure from d  in row 4 and column 1

=> only one connection rearrangement is needed

Page 100: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 100/36919 

4 - 37© P. Raatikainen Switching Technology / 2003

Recursive construction of switchingnetworks

• To reduce cross-point complexity of three stage switches individualstages can be factored further

• Suppose we want to construct an NxN  switching network and letN  = p xq 

• A rearrangeably non-blocking Clos network is constructedrecursively by connecting a p xp , q xq  and p xp  rearrangeably non-blocking switch together in respective order=> under certain conditions result may be a strict-sense non-

blocking network• A strict-sense non-blocking network is constructed recursively by

connecting a p (2p - 1), q xq  and p (2p - 1) strict-sense non-blockingswitch together in respective order=> result may be a rearrangeable non-blocking network

4 - 38© P. Raatikainen Switching Technology / 2003

3-dimensional construction of arearrangeably non-blocking network

q   PLANES   p   PLANES   q   PLANES

q xq 

p xp p xp 

Number of cross-points for the rearrangable construction is

p 2 q  + q 2 p  + p 2 q  = 2 p 2 q + q 2 p 

Page 101: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 101/36920 

4 - 39© P. Raatikainen Switching Technology / 2003

3-dimensional construction of a strict-sense non-blocking network

p x(2p-1) 

q   PLANES   p   PLANES

q   PLANES

q xq 

(2p-1)xp 

Number of cross-points for the strictly non-blocking construction is

p (2p - 1)q  + q 2 (2p - 1) + p (2p - 1)q  = 2p (2p - 1) q + q 2 (2p - 1) 

4 - 40© P. Raatikainen Switching Technology / 2003

Recursive factoring of switchingnetworks

•  N  can be factored into p  and q  in many ways and these can befactored further

• Which p  to choose and how should the sub-networks be factoredfurther ?

• Doubling in the 1st and 3rd stages suggests to start with the smallestfactor and recursively factor q  = N  / p  using the next smallest factor=> this strategy works well for rearrangeable networks=> for strict-sense non-blocking networks width of the network isdoubled=> not the best strategy for minimizing cross-point count

• Ideal solution: low complexity, minimum number of cross-points andeasy to construct => quite often conflicting goals

Page 102: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 102/36921

4 - 41© P. Raatikainen Switching Technology / 2003

Recursive factoring of a rearrangeablynon-blocking network

     N   I   N   P   U   T   S

     N   O   U   T   P   U   T

   S

N/2 x N/2SWITCH

N/2 x N/2SWITCH

• Special case N  = 2n , n  being a positive integer=> a rearrangeable network can be constructed by factoring N  into p  = 2 and q  = N  / 2 => resulting network is a Benes network=> each stage consists of N  /2 switch blocks of size 2x2

• Factor q  relates to the multiplexing factor (number of time-slots on inputs)=> recursion continued until speed of signals low enough for realimplementations

4 - 42© P. Raatikainen Switching Technology / 2003

Benes network

     N   I   N   P   U   T   S

     N   O   U   T   P   U   T   S

Number of stages in a Benes network

K = 2log 2 N - 1

Baseline network Inverse baseline network

Page 103: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 103/36922 

4 - 43© P. Raatikainen Switching Technology / 2003

Benes network (cont.)

• Benes network is recursively constructed of 2x2 switch blocks and itis rearrangeably non-blocking (see Clos theorem)

• First half of Benes network is called baseline network

• Second half of Benes network is a mirror image (inverse) of the firsthalf and is called inverse baseline network

• Number of switch stages is K = 2log 2 N - 1

• Each stage includes N  /2 2x2 switching blocks (SBs) and thusnumber of SBs of a Benes network is

Nlog 2 N - (N/2) = N(log 2 N -  ½  ) 

• Each 2x2 SB has 4 cross-points and number of cross-points in aBenes network is

4(N/2)(2log 2 N-1) = 4Nlog 2 N - 2N ∼    4Nlog 2 N 

4 - 44© P. Raatikainen Switching Technology / 2003

Illustration of recursively factoredBenes network

   1   6   I   N   P   U   T   S

   1   6   O   U   T   P   U   T   S

Page 104: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 104/3691

5 - 1© P. Raatikainen Switching Technology / 2003

Switch Fabrics

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

5 - 2© P. Raatikainen Switching Technology / 2003

Recursive factoring of a strict-sensenon-blocking network

• A strict-sense non-blocking network can be constructed recursively,but the size of network (number of cross-points) crows fast as afunction of the number of inputs, namely CNlog 2 N 

• Instead of starting with the smaller factor for p  let’s use switch

blocks of• Let N  = 2 n  and n  = 2 l   then we are factoring square switches with

number of inputs and outputs being power of 2=> condition for a strict-sense non-blocking network states thatthere are r 2  ≥ 2x2 n  /2  - 1 second stage SBs

• Let choose r 2  = 2x2 n  /2  then sizes of the- 1st stage switches are 2 n  /2  x 2 n  /2+1

- 3rd stage switches are 2 n  /2+1 x 2 n  /2 

• Each of these can be made of two SBs each of size 2 n  /2  x 2 n  /2 

N x N 

Page 105: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 105/369

Page 106: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 106/3693 

5 - 5© P. Raatikainen Switching Technology / 2003

Cantor network

     N   I   N   P   U   T   S

     N   O   U   T   P   U   T   S

  ( 

DEMULTIPLEXERS  ( 

MULTIPLEXERS

5 - 6© P. Raatikainen Switching Technology / 2003

Cantor network strict-sensenon-blocking

Proof:

• Markings

•  m  number of parallel Benes networks

•  k  number of stage in a Benes network

• A(k ) number of reachable 2x2 SBs without rearrangements instage k  (1≤k≤log 2 N ) starting from an input of a Cantor network

• Reachable 2x2 SBs in consecutive stages• A(1) = m 

• A(2) = 2A(1) - 1• A(3) = 2A(2) - 2• A(k ) = 2A(k -1) - 2k -2 = 22A(k -2) - 2x2k -2 = 2k -1A(1) - (k -1)x2k -2

• A(log 2 N ) = 2log 2 N-1m  - (log 2 N  -1) 2log 2 N-2 

= ½Nm - ¼ (log 2 N  -1 )N 

Page 107: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 107/3694 

5 - 7© P. Raatikainen Switching Technology / 2003

Cantor network strict-sensenon-blocking (cont.)

• Cantor network is symmetrical at the middle=> the same number of center stage nodes are reachable by anoutput of a Cantor network

• Total number of SBs in center stages is Nm  /2 (m  Benes networks)

• If the number of center stage SBs reached by an input and anoutput exceeds Nm  /2 then there must be a SB reachable from both

• Hence strict-sense non-blocking is achieved if

[ ]2 

Nm 1)N - N (log - Nm 2 

2 4 

1

1>

=> m  > log 2 N - 1

Notice that a strict-sense non-blocking Cantor network isconstructed of log 2 N rearrangeably non-blocking Benes networks

5 - 8© P. Raatikainen Switching Technology / 2003

Visualization of proof 

     N   I   N   P   U   T   S

     N   O   U   T   P   U   T   S

Page 108: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 108/3695 

5 - 9© P. Raatikainen Switching Technology / 2003

Dimensioning example of Cantor network

• number of multiplexers = 64 000

• number of demultiplexers = 64 000

• number of Benes networks  m  = log 2 N  = 16

=> number of outputs in demultiplexers = 16

=> number of inputs in Multiplexers = 16

• number of stages in Benes networks = 2log 2 N  - 1 = 2x16-1 = 31

• number of 2x2 SBs in Benes networks = Nlog 2 N  = 216 * 32

 ≈ 2N   SBs in each Benes network

Number of inputs and outputs of a switching network should beN = 32 x 2048 = 216 ≈ 64 000

5 - 10© P. Raatikainen Switching Technology / 2003

Control algorithms

• Control algorithms for networks, which are formed recursively bythree stage factorization

• Control algorithms can be applied recursively

• works well for strict-sense non-blocking networks when setting up

connections one at a time• for rearrangeable networks adding just one connections may cause the

connection pattern to change dramatically

=> adding a connection to a Benes network can be as complicated asreconnecting all input-output pairs

• Let’s examine control algorithm for a Benes network, formed byfactoring recursively

•    N  = 2m   inputs and outputs

• start with a totally disconnected network and establish requested

connection patterns

Page 109: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 109/3696 

5 - 11© P. Raatikainen Switching Technology / 2003

Looping algorithm

During the first factorization of an N xN  switch each 2x2 input SB maybe connected to a 2x2 output SB either via upper (U ) or lower (L)

N  /2xN  /2 switch (see figure)

1) Initialization Start with 2x2 input SB 1 and mark it by S 

2) Loop forward Connect an unconnected input of S  to desired output by upperswitch U . If no connection is required, go to 4.

3) Loop backward Connect the adjacent output of the output just visited to the desiredinput by the lower switch L. If no connection is required, go to 4.Otherwise, the newly visited input SB becomes S . Go to 2.

5 - 12© P. Raatikainen Switching Technology / 2003

Looping algorithm (cont.)

     N   I   N   P   U   T   S

     N   O   U   T   P   U   T   S

N/2 x N/2UPPERSWITCH

N/2 x N/2LOWERSWITCH

4) Start new loop Choose another SB, which has not been visited yet as S . Go to 2.If all connections for the N xN  switch are made, the algorithmterminates at level m .

Page 110: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 110/3697 

5 - 13© P. Raatikainen Switching Technology / 2003

Looping algorithm (cont.)

• Looping algorithm is applied recursively to establish connections forthe upper switch U  and lower switch L

• Computation of paths is complex and time consuming and it can beshown that the total run time of the algorithm to compute paths for allinputs and outputs is proportional to (log 2 N  )2 

• Looping algorithm

• suits for circuit switching, because connections computed per call

• not suitable for packet switching, because connections may haveto be recomputed for all N  input-output pairs within duration of apacket

• dedicating a processor for each input and output SB connection=> computations become faster, but exchange of path informationbetween processors gets very complicated

=> Alternative switching architectures needed for packet switching

5 - 14© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Multi-point switching

• Self-routing networks

• Sorting networks

• Fabric implementation technologies

• Fault tolerance and reliability

Page 111: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 111/3698 

5 - 15© P. Raatikainen Switching Technology / 2003

Graph presentation of connectionpatterns

Multi-cast switching 

I O I O

Point-to-point switching

One-to-one connections One-to-many connectionsC = {(i,o)| i∈I, o∈O}

If (i,o) ∈C and (i,o’)∈C => o=o’

If (i,o) ∈C and (i’,o) ∈C => i=i’

C = {(i,ni)| i∈I, ni⊂O}

C -  a logical mapping from inputs to outputs

5 - 16© P. Raatikainen Switching Technology / 2003

Graph presentation of connectionpatterns (cont.)

I O

Concentrator 

One-to-one connections

A

C = {(i,o)| i∈A⊂I, o∈O}

If (i,o)∈C and (i,o’)∈C => o=o’

If (i,o)∈C and (i’,o) ∈C => i=i’

I O

Super-concentrator (compact if B compact)

One-to-one connections

A

C = {(i,o)| i∈A⊂I, o∈Β⊂O}

If (i,o)∈C and (i,o’)∈C => o=o’

If (i,o)∈C and (i’,o)∈C => i=i’

Β

To anymember in O To any

member inspecific B

Page 112: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 112/3699 

5 - 17© P. Raatikainen Switching Technology / 2003

Graph presentation of connectionpatterns (cont.)

CopyI O

One-to-many connections

A

C = {(i,ni)| i∈A⊂I,Σni∈N}

Order and identity of outputsn i  ignored (output unspecific)

To any n i  members in O

5 - 18© P. Raatikainen Switching Technology / 2003

Combinatorial bound

•  ζ(G)  is log 2  of the number of distinct and legitimate C  realized by G 

•   R  is number of cross-points in a switch fabric

•  ζ measures combinatorial power of a graph, may bear no direct

relationship to control complexity of finding a switch setting to realizea connection pattern

•   R 2  is the number of states in a switch fabric of R  cross-points

=> rough upper bound for the number of C s in G  is ζ≤ R 

• Better upper bound obtained by removing- all non-legitimate states, e.g., those in which two cross-points arefeeding one output- one of states for which another state produces the same C 

• Such improvements not easily found

Page 113: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 113/36910 

5 - 19© P. Raatikainen Switching Technology / 2003

Combinatorial bound (cont.)

•  For each connection function, which defines a set of legitimate C ,we may compute the logarithm of the total number of distinct C ,

marked by ζ• A graph G  is rearrangeably non-blocking if all such C  can be

realized by G 

 => we must have ζ≤ ζ(G) for rearrangeably non-blocking G 

Let us look at number of different C  measured as ζ realized bydifferent connection functions

It follows that by observing the number of distinct C  realized bydifferent connection functions, we can find the lower bound ofcomplexity for any rearrangeably non-blocking fabric.

5 - 20© P. Raatikainen Switching Technology / 2003

Lower combinatorial bound for point-to-point connections

•  N xN  switch with full connectivity (any element in  I  can be connected toany distinct element in O)

• Obviously network that can realize all maximal connection patterns canrealize less than maximal patterns

• Number of C  we want to realize equals to N !

• Sterling’s approximation:

=> N ! ≈ √ N N+ ½ e -N  = √ exp2(Nlog 2 N - Nlog 2 e + ½log 2 N )

=> ζpt-pt  = log 2 N ! ≈ Nlog 2 N  - 1.44N  + ½log 2 N  = O (NlogN )

• If 2x2 SBs are used, at least Nlog 2 N such SBs are needed to realize

the N ! possible maximal connection patterns

=> A poit-to-point interconnection network has a complexity of O (NlogN )

2 π  2 π 

Page 114: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 114/36911

5 - 21© P. Raatikainen Switching Technology / 2003

Visualization of point-to-point mappings

N = 2 => Lc= 2

N = 3 => Lc= 6

Construction of C: Enumerate inputs, mix them in an arbitrary order.

Number of connection patterns in point-to-point switching Lc =  N! 

5 - 22© P. Raatikainen Switching Technology / 2003

Lower bound of Benes network

   1   6   I   N   P   U   T   S

   1   6   O   U   T   P   U   T   S

• Number of 2x2 SBs in a Benes network:=> 2log 2 N  - 1 stages and each stage has N  /2 SBs of size 2x2

=> total number of 2x2 SBs is N log 2 N  - N  /2 , which is close to ζpt-pt 

=> total number of cross-points 4(N log 2 N  - N  /2) ≈ 4N log 2 N 

Page 115: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 115/36912 

5 - 23© P. Raatikainen Switching Technology / 2003

Lower combinatorial bound for multi-point connections

• Let’s suppose that any input can be connected to any output, i.e.,each element in O may choose any one of the N  inputs=> total number of connection patterns C  is N N  = exp2(N log 2 N  )

=> ζmcast  = N log 2 N 

=> ζmcast  - ζpt-pt  = 1.44N 

• A fabric architecture that would implement multi-casting and wouldbe close to the lower bound of complexity is not known yet

• It is known that Benes network implements multi-cast if the numberof 2x2 SBs is doubled compared to the pt-to-pt case

5 - 24© P. Raatikainen Switching Technology / 2003

Visualization of multi-cast mappings

etc. …

Number of connection patterns in multi-cast switching Lc =  N N 

N = 3 => Lc= 27

Page 116: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 116/36913 

5 - 25© P. Raatikainen Switching Technology / 2003

Lower combinatorial bound for concentrator 

• A concentrator with M  inputs and N  outputs (M >N )

• Connection pattern C  defined to be a set of any N  of the M  inputs

• Number of these sets =  M 

  

   

ζ  concentrator

 = log   M! 

N!(M N)! 2  −

≈− −

log   M! 

2 N(M N)! 

N (M N)  2 

N M-N  π 

• Sterling’s approximation:

Entropy function: H(c) = -clog 2 c - (1-c)log 2 (1-c) 

M-1+N 

M-1

  

   

0

0,2

0,4

0,6

0,8

1

1,2

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1≈ MH(c) 

5 - 26© P. Raatikainen Switching Technology / 2003

Lower combinatorial bound for concentrator (cont.)

• For given C =>  ζconcentrator  = O(M) 

• This lower bound is smaller by a factor of logM  than that of point-to-point or multi-point networks

• Although concentrators with linear complexity (linear to number ofinputs) can be shown to exist, there are no known practicalsolutions - complicated control algorithms

• It can be shown that a strict-sense non-blocking concentrator is ascomplex as a point-to-point non-blocking concentrator - M logM 

•  => MlogM -fabrics are used for concentration

Page 117: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 117/36914 

5 - 27© P. Raatikainen Switching Technology / 2003

Visualization of concentrator mappings

Concentrator MxN = 4x2 => Lc = 6

Number of connection patterns in concentrator  Lc =  (  )=M N 

M! 

N!(N-M)! 

5 - 28© P. Raatikainen Switching Technology / 2003

Lower combinatorial bound for super-concentrator 

• A super-concentrator with M  inputs, N  outputs and K  elements(K ≤ M ,N )

• Connection pattern C  defined to be a legitimate set of C  = (A, B )by all A and B  with K  elements

• Total number of these sets =M 

  

     

   

ζ super con − ≈   

   

  

   

M H K 

M + N H 

• Super concentrators more complex than concentrators• Compact super-concentrator specifies output set B  once the

starting position of the compact sequence is specified => there are

N  possible starting positions and hence

ζ super con − ≈   

   

M H K 

M + log N  2 

Page 118: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 118/36915 

5 - 29© P. Raatikainen Switching Technology / 2003

Visualization of super-concentrator mappings

Super concentrator M=4, N=3 and K=2 => Lc = 18

Number of connection patterns in super-concentrator 

Lc =  (  )(  )=M K 

M!N! K!(M-K)!K!(N-K)! 

N K 

5 - 30© P. Raatikainen Switching Technology / 2003

Lower combinatorial bound for copy network

• A copy network with M  inputs and N  outputs

• Connection requests n i  over all inputs i  is equal to N 

=> Number of connection patterns C  equals to

=>> ζcopy  ≈ ( )M -1+ N   M 1

M 1 N H 

−− +

  

   

Complexity lower bound is liner in M  and N 

Page 119: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 119/369

Page 120: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 120/36917 

5 - 33© P. Raatikainen Switching Technology / 2003

Two stage factoring

M/p  x q  super concentrators

     p

   h  o  r   i  z  o  n   t  a   l  p  a   l  e  s

COMPACTSUPER CONCENTRATOR

p  x N/q  super concentrators

  q     v  e  r   t

   i  c  a   l

   p  a   l  e  s

2-stage factoring can be used to construct compact super-

concentrators

5 - 34© P. Raatikainen Switching Technology / 2003

Distribution network

• Mirror image of a compact super-concentrator is called a

distribution network

• Provided that an input-output connection pattern C = { (i ,o i ) }satisfies:

 - Compactness condition - active inputs i  for the pair in C  arecompact in modulo fashion

- Monotone condition - outputs o i  to be connected to each active

input are strictly increasing in i  in modulo fashion

a 2-stage network can be made a non-blocking one if the

connection requests arrive in sorted order - one way to achieve this

is to put a sorting network in front of a 2-stage network

• All point-to-point connections satisfying the above two conditions

can be connected using the distribution network

Page 121: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 121/36918 

5 - 35© P. Raatikainen Switching Technology / 2003

Compact and monotone connectionpattern

A modulo-wise compact set

01

2

3

4

  .

   .

  .

N -1

N -2

 N -3

.     

.     .    

0

1

2

3

4

5

N-4

N-3

N-2

N-1

0

1

2

3

4

5

N-4

N-3

N-2

N-1

Compact activeinputs

Cyclicallymonotone outputs

..

.

..

.

5 - 36© P. Raatikainen Switching Technology / 2003

Construction of a distribution network

COMPACTSUPER CONCENTRATOR DISTRIBUTION NETWORK

MIRROR IMAGE

Page 122: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 122/36919 

5 - 37© P. Raatikainen Switching Technology / 2003

Example of a distribution network

Distribution network based on inverse Banyan network

00000001

00100011

01000101

01100111

10001001

10101011

11001101

11101111

00000001

00100011

01000101

01100111

10001001

10101011

11001101

11101111

5 - 38© P. Raatikainen Switching Technology / 2003

Construction of copy networks

• Distribution network which allows multiple connections between an

input and outputs is called a copy distribution network

• An input can make extra connections to outputs if the outputs

connected remain monotonically increasing with respect to theinputs

- Compactness condition - active inputs i  for the pair in C  are

compact in modulo fashion

- Monotone condition - each element in O i  is greater than each

element in O i’  if i  >i’  in modulo fashion

• Inverse of many-to-one concentrator performs the copy functions

Page 123: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 123/36920 

5 - 39© P. Raatikainen Switching Technology / 2003

Copy distribution network

DISTRIBUTION NETWORK

MULTI-COPY INPUT

MONOTONESET OF O i 

5 - 40© P. Raatikainen Switching Technology / 2003

Compact and monotone connectionpattern

Many-to-one concentration One-to-many copying

0

1

2

34

5

N-4

N-3

N-2

N-1

...

0

1

2

34

5

N-4

N-3

N-2

N-1

...

Cyclically monotoneinput sets

Compactoutputs

Cyclically monotoneoutput sets

Compact activeinputs

MIRROR IMAGE 0

1

2

34

5

N-4

N-3

N-2

N-1

...

0

1

2

34

5

N-4

N-3

N-2

N-1

...

Page 124: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 124/369

Page 125: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 125/36922 

5 - 43© P. Raatikainen Switching Technology / 2003

Self-routing

• Self-routing is a popular principle in fast packet switching

• Header of each packet contains all information needed to routea packet through a switch fabric

• One or more paths may exist from an input to an output

• Interconnection network has the unique path property - if thesequence of nodes connecting an input to an output is uniquefor all input-output pairs

• An important class of networks having the unique property isthe generic banyan network- N logN  complexity- only one path connecting each input-output pair

5 - 44© P. Raatikainen Switching Technology / 2003

Examples of unique route network

Banyan network Baseline network

Shuffle exchange (Omega) network Flip network(inverse shuffle exchange)

Page 126: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 126/36923 

5 - 45© P. Raatikainen Switching Technology / 2003

Self-routing principle

Switch block S1

Self-routingaddress

b K ... b 1

Self-routingaddress

b K ... b 2

Self-routingaddress

b K

Switch block S2

Switch block SK

n 1

12

b 1

...

...

n 2

12

b 2

...

...

n K

12

b K

...

...

• S 1, S 

2  , … S 

K  is a sequence of switch blocks, which have n 1, n 2,

… n K outputs respectively

• Route of a packet uses the b k-th output of switch block k 

 => route given by the sequence b 1 b 2 … b k … b K

• At switch block k , packet routed to output b k and address b k is

removed from the self-routing header

5 - 46© P. Raatikainen Switching Technology / 2003

Self-routing principle (cont.)

000

001

010

011

100

101

110

111

000

001

010

011

100

101

110

111

 00

 01

 10

 11

 00

 01

 10

 11

 00

 01

 10

 11

U   P  =  0  D   

O   W   N   =  1   

Edge 011 Edge 110

• In a self-routing shuffle exchange (N xN ) network

- N = 2K  inputs and outputs interconnected by K  stages of 2K-1 nodes

- nodes numbered in each stage from 0 to 2K-1-1 (binary K -1 format)

- links (= edges) in each stage numbered from 0 to 2K -1 (binary K  format)

- outgoing links numbered by appending “0” (up going links) or “1” (down

going links) to the node’s number

Page 127: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 127/36924 

5 - 47© P. Raatikainen Switching Technology / 2003

Self-routing in a shuffle exchangenetwork

000

001

010

011

100

101

110

111

000

001

010

011

100

101

110

111

 00 00 00

01 01 01

10 10 10

11 11 11

Source

Edge 1

Edge 2

Edge 3

Edge 4

0 0 1 1 0 1

Destination

001

011

110

Edge 1 Edge 2 Edge 3 Edge 4

• Self-routing shuffle exchange scheme- a packet at input a 1a 2 … a K is destined to output b 1b 2 … b K- b 1b 2 … b K is used as the self-routing address (up link chosen if b k=0 and down

link if b k=1)- packet visits first node a 2…a K => travels along edge a 2…a Kb 1 => visits node

a 3…a Kb 1 =>… => finally after visiting node b 1…b n-1 arrives at output edge b 1…b n

5 - 48© P. Raatikainen Switching Technology / 2003

Monotone and compact addresses

• Top-down numbering of nodes and links can be used also for otherself-routing networks having the unique property

• If self-routing addresses of packets at the inputs satisfy conditions:

• addresses are strictly monotone in the sense that destinationaddresses are strictly increasing in top-down manner at theinputs

• packets are compact in the sense that there is no idle inputbetween any two inputs with packets

=>  self-routing paths used by these packets do not share any link  within the shuffle exchange network

=>  no need for buffering at inputs of the internal nodes

Page 128: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 128/36925 

5 - 49© P. Raatikainen Switching Technology / 2003

Limitations of banyan networks

• Banyan network can realize exp2(½N log2N ) = (N N )½ input-output

permutations (connection patterns)

• Full connectivity requires N ! connection patterns=> Banyan network is a blocking one

• Combinatorial power of banyan network can be increasedsignificantly by implementing- multiple links between nodes- duplicated switch- appended switch with random routing (shuffle)- buffering at intermediate nodes (=> undesirable random delay)

Page 129: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 129/3691

6 - 1© P. Raatikainen Switching Technology / 2003

Switch Fabrics

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

6 - 2© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Multi-point switching

• Self-routing networks

• Sorting networks

• Fabric implementation technologies

• Fault tolerance and reliability

Page 130: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 130/3692 

6 - 3© P. Raatikainen Switching Technology / 2003

Sorting networks

• Types of blocking

• Internal blocking

• Output blocking

• Head of line blocking

• Sorting to remove internal blocking

• Resolving output conflicts

• Easing of HOL blocking

6 - 4© P. Raatikainen Switching Technology / 2003

Internal blocking

• Internal blocking occurs at the internal links of a switch fabric

• In a switch fabric, which implements synchronous slot timing,internal blocking implies that some input (i) to output (j)connection cannot be established (even if both are idle ones)

• Internally non-blocking switch makes all requested connections(i , j i ), provided that there are no multiple request to the sameoutput ( j i  ≠  j i’ if i ≠ i’, 1≤i,j ≤N )

1

2

Inputi 

3

4

1

2

Output j 

3

4

Connection pattern = {(2, 1), (3, 4), (4, 3)}

Dest. j i 

1

4

3

Page 131: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 131/3693 

6 - 5© P. Raatikainen Switching Technology / 2003

Output blocking

• Internally non-blocking switch can block at an output of a switchfabric due to conflicting requests, i.e., j i  = j i’ for some i ≠ i’ 

• When output conflict occurs, switch should connect one of theconflicting inputs to requested output => output conflict resolution

• Major distinction between a circuit and packet switching node

• a packet switching node must solve output conflicts per time-slot (time-slots are not assigned beforehand)

• a circuit switching node solves

possible output conflicts and

assigns a time-slot for entireduration of a connectionbeforehand

1

2

Inputi 

3

4

1

2

Output j 

3

4

Dest. j i 

1

4

3

3

Conflicting output request

6 - 6© P. Raatikainen Switching Technology / 2003

Head of line (HOL) blocking

• Packets not forwarded due to output conflict are buffered=> more delay experienced

• Buffered packets normally served in a FCFS (First Come FirstServed) manner

=> HOL blocking introduced at the input queues• Packet facing HOL blocking

may prevent the next packet inthe queue to be delivered toa non-contended output=> throughput of a switchreduced

1

2

Inputi 

3

4

1

2

Output j 

3

4

Dest. j i 

14

43

31

32

Conflicting output requestPacket blockedby HOL queuing

Page 132: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 132/369

Page 133: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 133/3695 

6 - 9© P. Raatikainen Switching Technology / 2003

Sorting to remove internal blocking

• A permuted list ( a1, a

 2 , …, a

 N ) can be restored to its original order

by sorting

• A switching network for a maximal connection pattern can beobtained from a sorting network by treating 2x2 sorting elementsas 2x2 switching elements

• Asymptotic lower bound for 2x2 sorting elements to build a N xN 

sorting network is Nlog 2 N  (as for a respective switching network)

- no sorting network found so far to obtain this bound

• Sequential merge-sorting process can be used to obtain Nlog 2 N 

bound for the number of binary sorts

6 - 10© P. Raatikainen Switching Technology / 2003

Merge-sorting algorithm

Merge-sorting algorithm

• Input : unsorted list A N 

 = ( a1, a

 2 , …, a

 N )

• Sort procedure:Sort

 ( A

 N ) = Merge {Sort( a

1,…

, a ½N ), Sort (

 a ½N+1 ,

…, a N )}

• Merge procedure:Merge {( a

1, …, a m), ( a’ 

1, …, a’ 

 m’)}

  = { a1, (Merge (( a

 2, …, a

 m), ( a’ 

1, …, a’ 

 m’))} if  a

1≤  a’ 

1

= { a’ 1, (Merge (( a

1, …, a

 m), ( a’ 

 2, …, a’ 

 m’))} if  a

1>  a’ 

1

• Procedure Merge, called by procedure Sort, takes two sorted listsand merges them by comparing the smallest elements in each ofthe two sorted lists

Page 134: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 134/3696 

6 - 11© P. Raatikainen Switching Technology / 2003

Merge-sorting algorithm (cont.)

• Merging of two sorted lists (N/2 numbers in each) requires N binary sorts

• Total complexity of sorting N  numbers is given by

C (N ) = 2C (N  /2) = N  + 2(N  /2 + 2C (N  /4)) = … = Nlog 2 N 

• Due to sequential nature of procedure Merge the sorting takes atleast O(N ) time

1

461011151720

2

579

12141624

Compare numbersat the top of lists

then merge

6 - 12© P. Raatikainen Switching Technology / 2003

Odd-even merging

a 0 

a 1

a 2 

a 3 

a N/2-2 

a N/2-1

.

.

.

b 0 

b 1

b N/2-4 

b N/2-3 

b N/2-2 

b N/2-1

.

.

.

e 0 

e 1

e N/2-4 

e N/2-3 

e N/2-2 

e N/2-1

...

e 2 

e 3 

e 4 

e N/2-5 

Evenmerger 

N/2

Oddmerger 

N/2

     .     .     .

     .     .     .

     .     .     .

     .     .     .

     .     .     .

     .     .     .

d 0 

d 1

d N/2-3 

d N/2-2 

d N/2-1

.

.

.

c 0 

c 1

c N/2-2 

c N/2-1

.

.

.

c 2 

...

Recursive construction of an odd-even merger- number of sorting stages is log2N - number of sorting elements is 0.5N  [log2N -1]+1

Page 135: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 135/3697 

6 - 13© P. Raatikainen Switching Technology / 2003

Bitonic list

• Bitonic list  A N 

 = ( a1, a

 2 , …, a

 N ) is a list for which it holds that

 a1≤  a

 2 ≤ … ≤  a

 k-1 ≤

  a k 

and a k≥  a

 k+1 ≥ … ≥  a

 N-1 ≥  a

 N  (1≤ k  ≤ N )

• Unique cross-over property - when comparing a monotonically

increasing list with a monotonically decreasing list, there is at most oneposition where the two lists cross-over in their values (see figures)

1

4

610

11

15

17

20

24

16

1412

9

7

5

2

<

>

Bitonic list

Cross-over 

17

20

2416

14

12

9

7

5

2

14

6

10

11

15<

>

Circular bitonic list

Cross-over 

6 - 14© P. Raatikainen Switching Technology / 2003

Bitonic merging

a 0 

a 1

a N/2-2 

a N/2-1

.

.

.

a N/2 

a N/2+1

a N-2 

a N-1

.

.

.

Bitonicmerger 

N/2

Bitonicmerger 

N/2

 . . .

 . . .

 . . .

 . . .

d 0 

d 1

d N/2-3 

d N/2-2 

d N/2-1

.

.

.

c 0 

c 1

c N/2-2 

c N/2-1

.

.

.

c 2 

...

e 0 

e 1

e N/2-2 

e N/2-1

.

.

.

e N/2 

e N/2+1

e N-2 

e N-1

.

.

.

Recursive construction of a bitonic merger- number of sorting stages is log2N 

- number of sorting elements is 0.5N  log2N 

Page 136: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 136/3698 

6 - 15© P. Raatikainen Switching Technology / 2003

Sorting by merging

a 0 

a 1

a N/2-2 

a N/2-1

.

.

.

a N/2 

a N/2+1

a N-2 

a N-1

.

.

.

...

    

...

e 0 

e N-1

    

...

Merger N

Merger N/2

Merger N/4

Merger N/4

    

Merger N/2

Merger N/4

Merger N/4

    

    

...

...

Recursive construction of a sorting by merging network

- number of sorting stages is 0.5N log2N (log2N  + 1)

6 - 16© P. Raatikainen Switching Technology / 2003

Odd-even sorting network example

     2x2 UP SORTER

2x2 DOWN SORTER

2x2

SORTER

4x4

SORTER

8x8

SORTER

• Number of sorting stages is 0.5log2N (log2N  + 1)

• Number of sorting elements is 0.25N [log2N (log2N - 1) + 4] - 1

Page 137: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 137/3699 

6 - 17© P. Raatikainen Switching Technology / 2003

Bitonic sorting network example

     2x2 UP SORTER

2x2 DOWN SORTER

2x2SORTER

    

    

    

    

    

    

4x4SORTER

8x8SORTER

• Number of sorting stages is 0.5log2N (log2N  + 1)

• Number of sorting elements is 0.25N log2N (log2N  + 1)

6 - 18© P. Raatikainen Switching Technology / 2003

Batcher-Banyan self-routing network

     2x2 UP SORTER

2x2 DOWN SORTER

2x2BITONICSORTER

 

    

    

    

    

    

    

4x4BITONICSORTER

8x8BITONICSORTER

8x8ROUTER

SORTING NETWORK ROUTING NETWORK

Page 138: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 138/36910 

6 - 19© P. Raatikainen Switching Technology / 2003

Resolving output blocking

• Packet switches do not maintain a scheduler for dedicating time-slotsfor packets (at the inputs)=> output conflicts possible=> output conflict resolution needed on slot by slot basis

• Output conflicts solved by

• polling (e.g. round robin, token circulation)- do not scale for large numbers of inputs

- outputs just served have an unfair advantage in getting a new time-slot

• sorting networks (making a banyan network internally non-blocking)

• An example of sorting networks is sort-purge-concentrate  network

• when sorting self-routing addresses, duplicated output requests appearadjacent to each other in the sorted order (see figure)- either one has to be purged (deleted)- successful delivery is acknowledged and purged packets are re-sent

6 - 20© P. Raatikainen Switching Technology / 2003

Sort-purge-concatenate network

1

2

Inputi 

3

4

Output j 

4

Dest. j i 

1

2

3

Sortingnetwork

Concentrationnetwork

Compact and sortedoutput addresses

1

3

4

1

3

3

4

3

1

4

3

Purgenetwork

Routing network(Banyan)

Sorted destinationaddresses

• A sorting network can easily handle packet priority by- adding a priority field in the self-routing address

- higher priority packets are placed in a favorable position before purging- support of priority is an essential feature when integrating circuit andpacket switching in a sort-banyan network

Page 139: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 139/36911

6 - 21© P. Raatikainen Switching Technology / 2003

Resolving HOL blocking

• HOL blocking solved by

• allowing packets behind a HOL packet to contend for outputs

• allow multiple delivery of conflicting HOL packets to an outputbuffer - multiple rounds of arbitration for sort-banyan network - multiple planes of sort-banyan networks

•  a good solution is to implement multiple input buffers (one foreach output if possible) and if the packet in turn cannot betransmitted due to HOL, transmit an other packet from anotherbuffer

6 - 22© P. Raatikainen Switching Technology / 2003

Construction of a multipointpacket switch

In a self-routing multipoint switch- incoming packets destined to multiple outputs- packets carry all destination addresses in their headers

COMPACT SUPERCONCENTRATOR

COPY DISTRIBUTIONNETWORK

BANYAN SWITCH

COPY NETWORK ROUTING NETWORK

Page 140: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 140/36912 

6 - 23© P. Raatikainen Switching Technology / 2003

Batcher-Banyan example

     2x2 UP SORTER

2x2 DOWN SORTER

2x2BITONICSORTER

 

    

    

    

    

    

    

4x4BITONICSORTER

8x8BITONICSORTER

8x8ROUTER

SORTING NETWORK ROUTING NETWORK

000/110 (6)

001/100 (4)

010/ *** (-)

011/011 (3)

100/111 (7)

101/010 (2)

110/ *** (-)

111/001 (1)

Source/dest.

6

4

3

-

7

2

1

-

-

4

6

3

2

-

1

7

4

3

7

-

-

6

1

2

4

3

1

2

7

-

-

6

3

2

4

1

-

6

-

7

3

1

4

2

-

6

-

7

2

1

-

3

7

6

4

-

3

1

2

-

6

-

7

4

2

-

3

1

6

4

7

-

6 - 24© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Multipoint switching

• Self-routing networks

• Sorting networks

• Fabric implementation technologies

• Fault tolerance and reliability

Page 141: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 141/36913 

6 - 25© P. Raatikainen Switching Technology / 2003

Fabric implementation technologies

• Time division fabrics

• Shared media

• Shared memory

• Space division fabrics

• Crossbar

• Multi-stage constructions

• Buffering techniques

6 - 26© P. Raatikainen Switching Technology / 2003

Time division fabrics

• Shared media

• Bus architectures• Ring architectures

• Shared memory

Page 142: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 142/36914 

6 - 27© P. Raatikainen Switching Technology / 2003

Shared bus

Bus architecture• Switching in time domain, but time and space switching

implementations enabled

• Easy to implement and low cost (cost index = N )

• One time-slot carried through the bus at a time=> limited throughput (multi-casting possible)=> low number of line interfaces=> limited scalability

Buscontrol

LineInterface #2

LineInterface #3

LineInterface #n ...

LineInterface #1

6 - 28© P. Raatikainen Switching Technology / 2003

Shared bus (cont.)

Bus architecture• Internally non-blocking implementations require high capacity

switching bus => throughput ≥ aggregate capacity of line interfaces

• Inherently a single stage switch, but TST-switching possible if line-

cards support time-slot interchange• Multiple-bus structures can be used to improve reliability and

increase throughput

LineInterface #2

LineInterface #3

LineInterface #n 

...Line

Interface #1Bus

control

Bus 2

Bus 1

Page 143: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 143/36915 

6 - 29© P. Raatikainen Switching Technology / 2003

Ring architectures

Ring architecture• Rings coarsely divided into source and destination release rings

 – in source release (SR) rings only one switching operation inprogress at a time

=> limited throughput (like a shared bus)

 – destination release (DR) rings allow spatial reuse,

i.e., multiple time-slots can be carried through the ring simultaneously

=> improved throughput

• Switching in time domain, but time and spaceswitching implementations enabled

• Usually easy to implement and low cost(cost index = N )

• Scales better than a shared bus

6 - 30© P. Raatikainen Switching Technology / 2003

Ring architectures (cont.)

Ring architecture• Internally non-blocking implementations

require that throughput of a ring bus ≥

aggregate capacity of line interfaces

• Throughput can be improved by implementingparallel ring buses - control usually distributed=> MAC implementations may be difficult

• Multi-casting relatively easy to implement

• Inherently a single stage switch, but TST-switching possible if line-cards support time-slot interchange

• Multiple rings can be used to implementswitching networks

Page 144: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 144/36916 

6 - 31© P. Raatikainen Switching Technology / 2003

Ring architectures (cont.)

Dual ring architecture• Multiple rings used to improve throughput, decrease internal

blocking, improve scalability and increase reliability

6 - 32© P. Raatikainen Switching Technology / 2003

Shared memory

Shared memory architecture• Switching in time domain, but time and space switching

implementations enabled

• Inherently a single stage switch, but allows TST-switching if line-

cards support time-slot interchange

• Easy to implement and low cost (cost index = N )

Buffer memory

CPU

Bus

LineInterface #2

LineInterface #3

LineInterface #n 

...Line

Interface #1

Page 145: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 145/36917 

6 - 33© P. Raatikainen Switching Technology / 2003

Shared memory (cont.)

Shared memory architecture• Every time-slot carried twice through the bus

=> low throughput

=> low number of line interfaces

=> limited scalability

• Internally non-blocking if throughput of a switching bus and

speed of shared memory ≥ aggregate capacity of line interfaces

• Performance can be improved by dual bus architecture orreplacing the bus with a space switch (such as crossbar)

6 - 34© P. Raatikainen Switching Technology / 2003

Shared memory (cont.)

Shared memory architecture

• Dual-bus architecture improves throughput, decreases internalblocking, improves scalability and increases reliability

• Memory speed requirement equal to that of single bus solutions

LineInterface #2

LineInterface #3

LineInterface #n ...

LineInterface #1

Buffer memory

CPU

Bus 1

Bus 2

Page 146: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 146/36918 

6 - 35© P. Raatikainen Switching Technology / 2003

Dimensioning example

A shared memory architecture, which uses a shared bus toconnect line interfaces to the memory, is used to implement aswitching equipment. The bus is 32 bits wide and bus clock is 150MHz. Three clock cycles are needed to transfer a 32 bit word

through the bus and 20 % of the bus capacity is used for otherthan switching purposes. How many E1 interfaces can besupported by the switch ? What is the required memory speed ?

Solution:If the bus transfers an eight bit time-slot (of a 64 kbit/s PDH channel)across the bus at a time, a single bus solution can transfer0.8x(150/3) Mbytes/s = 40 Mbytes/s

6 - 36© P. Raatikainen Switching Technology / 2003

Dimensioning example (cont.)

Solution (cont.):

In a single bus solution, half of the bus capacity (20 Mbytes/s) is usedfor storing time-slots to memory and another half for reading time-slotsfrom memory

 => memory speed requirement is 1/(20 Mbytes/s) = 50 ns => during a 125 µs period (= duration of an E1 frame) the busswitches 125x20 bytes = 2500 time-slots and the number of supportedE1 links is 2500/32 ≈ 78

Throughput of the switching system can be increased by adding a 32 bitreceive-register to the shared switch memory block, which enables to transfer

4 time-slots (in parallel) through the bus at a time. By doing so, the throughputof the bus gets four fold and the number of supported E1 links increases to

312. Time-slots are still written one by one to the switch memory, and thus thememory speed requirement is 12.5 ns.

Page 147: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 147/36919 

6 - 37© P. Raatikainen Switching Technology / 2003

Space division fabrics

• Crossbar 

• Multi-stage constructions

6 - 38© P. Raatikainen Switching Technology / 2003

Crossbar 

Crossbar architecture• Inherently a space division switch

• Allows to build TST-switches if interfaces implement time-slotinterchange functionality

• Hard to implement large switches due to complicated controlschemes=> high cost (cost index = N 2 )

• Commercial high-speed NxN  crossbar components enablemodular and relatively inexpensive fabric constructions, but stillcontrol of the switch is a problem

Page 148: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 148/36920 

6 - 39© P. Raatikainen Switching Technology / 2003

Crossbar (cont.)

Crossbar architecture• Inherently a strict-sense non-blocking fabric architecture

• Possible to carry N  time-slots through the switch at a time

=> high throughput

=> possible to implement a large number of line interfaces

=> scales well within the limits of available modular components

=> scaling up means increase of cross-point count from N xN  to

to (N +k )x (N +k )

• Multi-casting easy to implement

Switch control

6 - 40© P. Raatikainen Switching Technology / 2003

Crossbar (cont.)

C - connection control

Example implementation of a crossbar

c c c

c c c

c c c

AND

AND

AND

AND

AND

AND

AND

AND

AND

...

...

...

......

...

1

2

...

1 2   n ...

Outputs

   I  n  p  u   t  s

Page 149: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 149/36921

6 - 41© P. Raatikainen Switching Technology / 2003

Crossbar (cont.)

An 8x8 switch constructed of four 4x4 crossbar blocks

Notice that doubling of input/output count increases the number ofcrossbar components from one to four.

6 - 42© P. Raatikainen Switching Technology / 2003

Multi-stage building blocks

• Multi-stage switches usually constructed of 2x2 switching blocks

• Implemented usually in FPGAs (Field Programmable Gate Arrays)and/or ASICs (Application Specific Integrated Circuit)

• FPGA for experimental use and low volume production

• ASICs for high volume production

• Batcher-banyan network most popular

• Used to implement space divisionswitching

• Allows to build TST-switches ifinterfaces implement time-slotinterchange functionality

XIn1

In2

Out1

Out2

XIn3

In4

Out1

Out2

XIn5

In6

Out1

Out2

XIn7

In8

Out1

Out2

XIn1

In2

Out1

Out2

XIn1

In2

Out3

Out4

XIn1

In2

Out5

Out6

XIn1

In2

Out7

Out8

Switch networkcomposed of 2x2 blocks

Page 150: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 150/36922 

6 - 43© P. Raatikainen Switching Technology / 2003

Multi-stage building blocks (cont.)

• Hard to implement large circuit switches due to complicated controlschemes (especially rearrangeable fabrics)=> high cost (cost index ∼ CNlog 2 N )

• Suitable for packet switching when self-routing functionality included

• Fixed duration time-slot implementations favored to obtain strict-

sense non-blocking fabrics

• Possible to carry N  time-slots through the switch at a time=> relatively high throughput=> scalable only if larger networks can be factored using smaller

N xN  components=> scaling up means increase of cross-point count from ∼ CNlog 2 N to ∼ C (N +k )log 2 (N +k )

XIn1

In2

Out1

Out2

6 - 44© P. Raatikainen Switching Technology / 2003

Problems with multi-stages

• Path search required

• Fast connection establishment implies need for fast control system => part of switching capacity is lost if control system is not fastenough

• Multi-cast is not self evident, because multi-cast complicates pathsearch and control scheme and increases blocking probability

• Multi-slot connections (i.e. several slots used for a particularconnection) complicate matters- especially if path delay is not constant, e.g., slots belonging to thesame connection may arrive to outputs in different order than theywere at the inputs- blocking increases

Page 151: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 151/36923 

6 - 45© P. Raatikainen Switching Technology / 2003

Trends in fabric technologies

• Memory technology getting faster and faster

• Current SRAM (Static Random Access Memory) technology allowseasy implementations of large PDH switches, e.g. full matrix for 8000E1 (2M) PDH circuits - bigger fabrics hardly needed in narrow band

networks=> in narrow band networks the trend over the last 10 years hasbeen to build full matrix fabrics based on shared memory

• However, when striving for broadband communications, memory

based switch fabrics do not scale to bandwidth needed=> multi-stage and crossbar switches have their change

6 - 46© P. Raatikainen Switching Technology / 2003

Trends in fabric technologies (cont.)

• Multistage fabrics were “reinvented” at the advent of ATM- ATM suits perfectly for fixed length time-slot switching- self-routing and sorting applies for ATM cell routing- blocking and buffering causes headache=> in spite of huge research effort, there have been very few commercial

multi-stage fabrics available (mostly proprietary ASICs)

• Development of IC technologies, increased packing density (numberof gates/chip) and increased speed, have enabled crossbar fabricssuitable for high-speed switching applications (N = 2 … 64 and linerate 2.5 … 40 Gbit/s)- examples: Cx27399/Mindspeed, ETT1/Sierra, CE200/Internet Machinesand PI140xx/Agere

• Packet switching and advent of optical networking favors multi-stages and crossbars=> packet switching introduces a new problem - buffering

Page 152: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 152/36924 

6 - 47© P. Raatikainen Switching Technology / 2003

Technological tradeoffs in switch fabricdesign

• When trying to simplify path search and to speed up connection

establishment=> bus speed increases (inside fabric)

=> faster memory required => power consumption increases

=> integration level of a cross-point product needs to be increased

=> faster memory required, etc.

• If fast memory not available, use=> crossbar fabrics (for small switches)=> multistage fabrics (for large switches)

- real switching capacity may be less

  than theoretical

- minimization of cross-point count

  often pointless   L  e  v  e   l  o   f

  c  r  o  s  s  -

  p  o   i  n   t   i  n   t  e  g  r  a   t   i  o  n

Memory speed

   B  u  s  s  p  e  e   d

Complexity of path search

6 - 48© P. Raatikainen Switching Technology / 2003

Electronic design problems

• Signal skew - caused by long signal lines with varying capacitive load

inside switch fabric and/or on circuit boards

• Mismatching line termination - caused by long signal lines combined

with varying (high) bit rates

• Varying delay on bus lines - caused by differently routed bus lines (non-uniform capacitive load)

• Crosstalk - caused by electro-magnetic coupling of signals from adjacent

signal lines

• Power feeding and voltage-swing - incorrectly dimensioned power

source/lines cause non-uniform voltage and lack of adequate filtering causes

fluctuation of voltage

• Mismatching timing signals - different line lengths from a centralized

timing source cause phase shift and distributed timing may suffer from lack of

adequate synchronization

Page 153: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 153/36925 

6 - 49© P. Raatikainen Switching Technology / 2003

Some design limitations

• Speed of available components vs. required wire speed and slottime interval

• Component packing density and power consumption vs. heatingproblem

• Maximum practical fan-out vs. required size of fabric

• Required bus length inside switch fabric- long buses decrease internal speed of fabric- diagnostics get difficult

• IPR policy- whether company wants to use special components or moregeneral all-purpose components

6 - 50© P. Raatikainen Switching Technology / 2003

Design optimization example

• An N xN  switch fabric is to be designed and there are three alternativecrossbar components a , b  and c  available- a is an N a xN a  fabric component

- b  is an N b xN b  fabric component- c  is an N c xN c  fabric component

and N a <N b <N c ≤N • Component a  has entered the market at time t a , b  at time t b  and c  at time t c • Product development starts at t pd  and the switch product should come in the

market at t m . Components are expected to be available when the productdevelopment starts => t a  < t b  < t c ≤ t pd  < t m 

• Price of a component develops with time and is generally given byP(t)=Cf(t) + D , where Cf(t) is a time dependent and D  a constant part of

component’s price

• Question: Which one of the three components to choose for constructing anN xN  switch fabric ?

Page 154: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 154/36926 

6 - 51© P. Raatikainen Switching Technology / 2003

Design optimization example (cont.)

• As an example, let’s assume that price of each component is a function of

time and is given by P(t)=Ce -t/T + D  ,

where C , D  and T  are component specific constants

=> Pa (t)=C a e -t/T a + D a , Pb (t)=C b e -t/T b + D b and Pc (t)=C c e -t/T c + D c 

• Number of alternative crossbar components needed to build an N xN  switch

=> K a  = ceil[N  / N a ]2, K b  = ceil[N  / N b ]

2 , K c  = ceil[N  / N c ]2

• Alternative component costs as a function of time t 

=> Pa (t )=C a e -(t- t a  )/T a + C a 

=> Pb (t )=C b e -(t- t b  )/T b + C b 

=> Pc (t )=C c e -(t- t c  )/T c + C c 

• These functions can be used to draw price development curves to make

comparisons

6 - 52© P. Raatikainen Switching Technology / 2003

Design optimization example (cont.)

Numerical example:

• Let N  = 64, N a  = 16, N b  = 32, N c  = 64, T a  = T b  = T c  = 3 time units (years),

C a  = 20,C b  = 50, C c  = 100 and D a  = 10, D b  = 20, D c  = 40 price units (euros)

• Product development period is assumed to be 1 time unit (year) and

t b  = t a  +1.5, t c  = t a  +3, t m  = t a  +4 => t pd  = t a  + 3

• Choosing that t pd  = t o  = 0  => t a  = t + 3, t b  = t  +1.5, t c  = t , t m  = t  -1 (t  ≥ t pd  = 0 )

• Number of components needed K a  = 16, K b  = 4, K c  = 1

• Switch fabric component cost functions

=> Pa (t )=16[20e -(t+3)/ 3 + 10]

=> Pb (t )=4[50e -(t+ 1.5 )/ 3 + 20]

=> Pc (t )=100e -(t)/ 3 + 40

Page 155: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 155/36927 

6 - 53© P. Raatikainen Switching Technology / 2003

Design optimization example (cont.)

• Although the price of component c  is manifold compared to the price ofcomponent a  or b , c  turn out to be the cheapest alternative

• Another reason to choose c  is that it probably stays longest in the marketgiving more time for the switch product

Numerical example (cont.) :

Component cost

0

20

40

60

80

100

120

140

160

0 1 2 3 4 5 6

Time

   C  o  s   t

Pa(t) Pb(t) Pc(t)

Switch fabric cost

0

50

100

150

200

250

300

350

0 1 2 3 4 5 6

Time

   C  o  s   t

Ta(t) Tb(t) Tc(t)

Page 156: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 156/3691

7 - 1© P. Raatikainen Switching Technology / 2003

Switch Fabrics

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

7 - 2© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Multipoint switching

• Self-routing networks

• Sorting networks

• Fabric implementation technologies

• Fault tolerance and reliability

Page 157: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 157/3692 

7 - 3© P. Raatikainen Switching Technology / 2003

Fabric implementation technologies

• Time division fabrics

• Shared media

• Shared memory

• Space division fabrics

• Crossbar

• Multi-stage constructions

• Buffering techniques

7 - 4© P. Raatikainen Switching Technology / 2003

Buffering alternatives

• Input buffering

• Output buffering

• Central buffering

• Combinations

– input-output buffering

– central-output buffering

Page 158: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 158/369

Page 159: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 159/3694 

7 - 7© P. Raatikainen Switching Technology / 2003

Output buffering

Buffer memories at the output interfaces

OUTPUTBUFFERING

SWITCHFABRIC

7 - 8© P. Raatikainen Switching Technology / 2003

Output buffering (cont.)

• Pros

• better throughput/delay performance than in input bufferedsystems

• no HOL problem

• Cons

• access speed of buffer memory- in FIFO and dual-port RAM solutions N  times the incoming line rate

- in one-port RAM solutions N +1 times the incoming line rate

• high cost due to high memory speed requirement

• switch fabric operates at the aggregate speed of inputs(N x wire speed)

Page 160: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 160/3695 

7 - 9© P. Raatikainen Switching Technology / 2003

Central buffering

Buffer memory located between two switch fabrics- shared by all inputs/outputs- virtual buffer for each input or output

SWITCHFABRIC 1

CENTRALBUFFERING

SWITCHFABRIC 2

7 - 10© P. Raatikainen Switching Technology / 2003

Central buffering (cont.)

• Pros

• smaller buffer size requirement and lower average delay than ininput or output buffering

• HOL problem can be avoided• Cons

• speed of buffer memory- in dual-port RAM solutions larger than N  times the incoming line rate

- in one-port RAM solutions larger than 2xN  times the incoming line rate

• speed of switch fabric N  x wire speed

• complicated buffer control

• high cost due to high memory speed requirement and controlcomplexity

Page 161: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 161/3696 

7 - 11© P. Raatikainen Switching Technology / 2003

Input-output buffering

Input-output buffering common in QoS aware switches/routers- inputs implement output specific buffers to avoid HOL

- outputs implement dedicated buffers for different traffic classes

- combined buffering distributes buffering complexity between inputs and outputs 

INPUTBUFFERING

OUTPUTBUFFERING

SWITCHFABRIC

7 - 12© P. Raatikainen Switching Technology / 2003

Input-central buffering

INPUTBUFFERING

SWITCHFABRIC 1

CENTRALBUFFERING

SWITCHFABRIC 2

Input-central buffering used in QoS aware switches/routers- inputs implement output specific buffers to avoid HOL

- central buffer implements dedicated buffers for different traffic classes foreach output

Page 162: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 162/3697 

7 - 13© P. Raatikainen Switching Technology / 2003

Summary of buffering techniques

Bufferingprinciple

Inputbuffering

Outputbuffering

Centralbuffering

Memoryspace

high

medium

low

Memoryspeed

slow(~input rate)

fast(~N x input rate)

fast(~N x input rate)

Memorycontrol

simple

simple

complicated

Queueingdelay

longest(due to HOL)

medium

shortest

Multi-castingcapabilities

extra logicneeded

supported

supportedbut complex

7 - 14© P. Raatikainen Switching Technology / 2003

Priorities and buffering

• Separate buffer for each traffic class• A scheduler needed to control transmission data

• highest priority served first• longest queue served first

• minimization of lost packets/cells• Priority given to high quality traffic• low delay and delay variation traffic• low loss rate traffic

• best customer traffic

• Scheduling principles• round robin• weighted round robin• fair queuing• weighted fair queuing• etc.

OUTPUT/CENTRALBUFFERING

CLASS 1

CLASS 2

CLASS 3

CLASS 4

Page 163: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 163/3698 

7 - 15© P. Raatikainen Switching Technology / 2003

Basic memory types for buffering

• FIFO (First-In-First-Out)

• RAM (Random Access Memory)

• Dual-port RAM

7 - 16© P. Raatikainen Switching Technology / 2003

Basic memory types for buffering (cont.)

Read/Write

RAM

DUAL-PORT RAM

Write Read

FIFO

Page 164: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 164/3699 

7 - 17© P. Raatikainen Switching Technology / 2003

Switch fabrics

• Multipoint switching

• Self-routing networks

• Sorting networks

• Fabric implementation technologies

• Fault tolerance and reliability

7 - 18© P. Raatikainen Switching Technology / 2003

Fault tolerance and reliability

• Definitions

• Fault tolerance of switching systems

• Modeling of tolerance and reliability

Page 165: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 165/36910 

7 - 19© P. Raatikainen Switching Technology / 2003

Definitions

• Failure, malfunction - is deviation from theintended/specified performance of a system

• Fault - is such a state of a device or a programwhich can lead to a failure

• Error - is an incorrect response of a program ormodule. An error is a indication that the module inquestion may be faulty, the module has received

wrong input or it has been misused. An error canlead to a failure if the system is not tolerant to thissort of an error. A fault can exist without any errortaking place.

7 - 20© P. Raatikainen Switching Technology / 2003

Fault tolerance

• Fault tolerance is the ability of a system to continueits intended performance in spite of a fault or faults

• A switching system is an example of a faulttolerant system

• Fault tolerance always requires redundancy of somesort

Page 166: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 166/36911

7 - 21© P. Raatikainen Switching Technology / 2003

Categorization of faults

• Duration based

• permanent or stuck-at (stuck at zero or stuck at one)

• intermittent - fault requires repair actions, but its impact is not

always observable

• transient - fault can be observed for a short period of time and

disappears without repair

• Observable or latent (hidden)

• Based on the scope of the impact (serious - lessserious)

7 - 22© P. Raatikainen Switching Technology / 2003

Graceful degradation

• Capability of a system to continue its functionsunder one or more faults, but on a reduced level of performance

• For example

• in some RAID (Redundant Array Inexpensive Disks)

configurations, write speed drops in case of a disk fault, but

continues on a lower level of performance even while the fault

has not been repaired

Page 167: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 167/36912 

7 - 23© P. Raatikainen Switching Technology / 2003

Reliability and availability

• Reliability R(t)  - probability that a system does not fail

within time t  under the condition that it was functioning

correctly at t = 0

• for all known man-made systems R(t) → 0  when t  → ∞

• Availability A(t)  - probability that a system will function

correctly at time t 

• for a system that can be repaired A(t)  approaches some valueasymptotically during the useful lifetime of the system

7 - 24© P. Raatikainen Switching Technology / 2003

Repairable system

• Maintainability M(t)  - probability that a system is

returned to its correct functioning state during time t 

under the condition that it was faulty at time t  = 0

Page 168: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 168/36913 

7 - 25© P. Raatikainen Switching Technology / 2003

MTTF, MTTR and MTBF

• MTTF (Mean-Time-To-Failure) - expected value of thetime duration from the present to the next failure

• MTTR (Mean-Time-To-Repair) - expected value of the

time duration from a fault until the system has been

restored into a correct functioning state

• MTBF (Mean-Time-Between-Failures) - expected value

of the time duration from occurrence of a fault until the

next occurrence of a fault

• MTBF = MTTR + MTTR

7 - 26© P. Raatikainen Switching Technology / 2003

High availability of a switching system

• High availability of a switching system is obtained bymaintenance software

Detection oferrors and

faults

Supervision 

Fault analysisand

pinpointing

Alarm system

 Recovery- eliminationof faults

Recovery

Faultlocation

Diagnostics

• In a unit under normalworking load

• HW implementation => fast

• SW implementation => detection delay

• Often a rulebased system

Utilizes• redundancy• switch-overs

- active <=> standby• restarts

- a single program- a preprocessor - a single main processor - whole system- fall back to previous SW package

• In a unit temporarilywithout normalload

Maintenance software is one of themost important software sub-systemsin a switching system in parallel withcall/connection control and charging

Page 169: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 169/36914 

7 - 27© P. Raatikainen Switching Technology / 2003

Main types of redundancy

• Hardware redundancy• duplication (1+1) - need for “self-checking”-recovery blocks that

detect their own faults

• n +r  -principle (n  active units and r  standby units)

• Software redundancy• required always in telecom systems

• Information redundancy

• parity bits, block codes, etc.

• Time redundancy• delayed re-execution of transactions

7 - 28© P. Raatikainen Switching Technology / 2003

Modeling of reliability

• Combinatorial models

• Markov analysis

• Other modeling techniques (not covered here)- Fault tree analysis- Reliability block diagrams- Monte Carlo simulation

Page 170: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 170/36915 

7 - 29© P. Raatikainen Switching Technology / 2003

Combinatorial reliability

S 1 S 2  S n 

S 1

S 2 

S n 

• A serial system S  functions if and only if allits parts S 

i  (1≤i ≤n ) function

=> R s  = Π R 

iand F 

s  = (1- R 

s )

• Failures in sub-systems are supposed to beindependent

i=1

• A parallel (replicated) system fails if all its sub-systems fail

=> F s  = Π (1-R 

i )  and R 

s  = 1- F 

s  = 1- Π (1-R 

i )

• Reliability of a duplicated system (R i  = R ) is

R s  = 1- (1-R )2

 n 

 i=1

i=1

7 - 30© P. Raatikainen Switching Technology / 2003

Combinatorial reliability example 1

• Calculate reliability R s  and failure probability F 

s  of system S 

given that failures in sub-systems S i  are independent and for

some time interval it holds that

R 1 = 0.90, R 

2  = 0.95 and R 

3  = R 

4  = 0.80

=> R s  = Π R 

i  = R 

1x R 

2  x R 

3-4 

=> R 3-4 

 = 1- Π (1-R i ) = 1- (1- R 

3 )(1- R 

4 )

=> R s  = R 

1x R 

2  x [1- (1- R 

3 )(1- R 

4 )]

=> F s  = 1- R 

s  = 1 - R 

1x R 

2  x [1- (1- R 

3 )(1- R 

4 )]

=> R s  = 0.82 and F 

s  = 0.18

S 1 S 2 

S S 3 

S 4 

S 3-4 

Page 171: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 171/36916 

7 - 31© P. Raatikainen Switching Technology / 2003

Combinatorial reliability (cont.)

S 1

S 2 

S n 

m/n

• A load sharing system functions if m  of the total of

n  sub-systems function

• If failures in sub-systems S i  are independent then

probability that the system fails is

P(fails) = P(k <m )

and probability that it functions is

P(functioning) = P(k ≥m ) = 1- P(k <m )

where k  is the number of functioning sub-systems

P(k ≥m ) = Σ P(k =i ) and  P(k <m ) = Σ P(k =i )n 

i=m 

  m-1

i=0 

7 - 32© P. Raatikainen Switching Technology / 2003

Combinatorial reliability example 2

• As an example, suppose we have a system having m =2 and n =4

and each of the four sub-systems have a different R , i.e. R 1, R 

2 , R 

and R 4 , and failures in sub-systems S 

i  are independent

• Probability that the system fails is

P(fails) = P(k <2 ) = Σ P(k =i ) = P(k =0 ) + P(k =1)

• P(k=0) and P(k=1) can be derived to be

P(k =0 ) = (1- R 1)(1- R 2 )(1- R 3 )(1- R 4 )

P(k =1) = R 1(1- R 2 )(1- R 3 )(1- R 4 ) + (1- R 1)R 2 (1- R 3 )(1- R 4 ) +

 (1- R 1)(1- R 2 ) R 3 (1- R 4 ) + (1- R 1) (1- R 2 )(1- R 3 ) R 4 

• If R 1=0.9 ,R 

2 ,=0.95 ,R 

3  =0.85 and R 

4=0.8 then

 R s  = 0.994 and F 

s  = 0.0058

1

i=0 

S 1

S 2 

S 4 

2/4

S 3 

Page 172: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 172/36917 

7 - 33© P. Raatikainen Switching Technology / 2003

Combinatorial reliability (cont.)

• If failures in sub-systems S i  of an m  / n  systemare independent and R i  = R   for all i ∈[1,n]then the system is a Bernoulli system andbinomial distribution applies

=> R s  = Σ  ( )R k (1-R) n-k 

• For a system of m  / n  = 2/3

=> R 2/3  = Σ −−−− R k (1-R) 3-k  = 3R 2  - 2R 3 

If for example R  = 0.9 => R 2/3  = 0.972

S 1

S 2 

S n 

m/n

3! k!(3-k)! 

k=2 

k=m 

7 - 34© P. Raatikainen Switching Technology / 2003

Computing MTTF

• MTTF = ∫ R(t)dt - valid for any reliability distribution

• Single component with a constant failure rate (CFR) λ

- R(t) = e-λt

- MTTF = 1/λ

• Serial systems with n  CFR components

- Rs(t) = R1(t) x R2(t) x ... x Rn(t) = e- (λ1 + λ2 + ... + λn)t = e- λst

- λs= λ1 + λ2 + ... + λn

• MTTFs = 1/ λs

• 1/MTTFs = 1/MTTF1 + 1/MTTF2 + ... + 1/MTTFn

  ∞

0

Page 173: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 173/36918 

7 - 35© P. Raatikainen Switching Technology / 2003

Telecom exchange reliability fromsubscriber’s point of view

Line-card

n-1/n

Subscriber modulecontrol

Centralized

functionsSubscriber callcontrol

Exchangeterminal

CCS7 signaling processors• (n-1)/n operational processors

for call setup

• chosen processor functionsduring a call

Premature release requirement P ≤ 2x10-5 applied

7 - 36© P. Raatikainen Switching Technology / 2003

Failure intensity

• Unit of failure intensity λ is defined to be[λ] = fit = number of faults /109 h

• Failure intensities for replaceable plug-in-units varies in the

range 0.1 - 10 kfit

• Example:

• if failure intensity of a line-card in an exchange is 2 kfit, whatis its MTTF ?

MTTF = 1/λ =    =        = 58 years109 h2000

1 000 000 h2x24x360

Page 174: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 174/36919 

7 - 37© P. Raatikainen Switching Technology / 2003

Reliability modeling using Markov chains

Markov chains• A system is modeled as a set of states of transitions

• Each state corresponds to fulfillment of a set of conditions and each

transition corresponds to an event in a system that changes from

one state to another

• By using this method it is possible to find reliability behavior of a

complex system having a number of states and non-independent

failure modes

State 1 State 2

7 - 38© P. Raatikainen Switching Technology / 2003

Markov chain modeling

• A set of states of transitions leads to a group of linear differential

equations

• For a given modeling goal it is essential to choose a minimal set of

states for equations to be easily solved

• By setting the derivatives of the probabilities to zero an asymptoticstate is obtained if such exists

λ  = failure intensity

µ  = repair intensity (repair time is exponentially distributed)

P i   = probability of state i , e.g. P 0  = R (t ) and P 1 = F (t ),

P0 P1

λ

µ

Page 175: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 175/36920 

7 - 39© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

• Probabilities (πi ) of the states and transition rates (λij ) between the

states are tied together with the following formula

0=Λπ 

[ ] n

π π π π   

21=

( )

( )( )

++−

++−

++−

32313231

23232121

13121312

λ λ λ λ 

λ λ λ λ 

λ λ λ λ 

where

7 - 40© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Example

0=Λπ  [ ] n

π π π π 21

=S3

λ12

S2S1

λ21

λ13

λ31

λ32

λ23

( )

( )

( )

+−

+−

+−

32313231

23232121

13121312

λ λ λ λ 

λ λ λ λ 

λ λ λ λ 

( )

( )

( )

=+−+

=++−

=+++−

0

0

0

33231232131

32322321121

31321211312

π λ λ π λ π λ 

π λ π λ λ π λ 

π λ π λ π λ λ 

and

Page 176: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 176/36921

7 - 41© P. Raatikainen Switching Technology / 2003

Birth-death process

Birth-death process is a special case of continuous-time Markov

chain, which models the size of population that increases by 1 (birth)

or decreases by one (death).

S0

λ0

µ1

S1

λ1

µ2

S2

λ2

µ3

S3

λ3

µ4

...

=>

Balance equations:

- State S 0 

- State S 1

- State S k 

=>

=>

λ π λ π  0 0 1 1

=

( )λ µ π λ π λ π  1 1 1 0 0 2 2+ = +

( )λ µ π λ π λ π   k k k k k k k− − − − −

+ = +1 1 1 2 2

π λ 

µ π 

1

0

1

0=

π λ λ 

µ µ π 

2

1 0

2 1

0=

π λ λ λ 

µ µ µ π 

 k

 k

 k

= −1 1 0

2 1

0

 

 

7 - 42© P. Raatikainen Switching Technology / 2003

Birth-death process (cont.)

Sk

λk

µk+1

Sk+1

=>

π λ 

µ 

λ 

µ 

λ 

µ π ρ ρ ρ π  

 k

 k

 k

 k=  

   

  

     

    =−

−1 1

2

0

1

0 1 1 1 0

  ρ λ 

µ  k

 k

 k

=+1

π  k

 k=

∑ =0

1

(k =1, 2, 3, …)where

Substituting these expressions for πk  into yields

π λ λ λ 

µ µ µ π 

0

1 1 0

2 1

0

1

1+ =−

=

∑  k

 k k

=>  π 

λ λ λ 

µ µ µ 0

1 1 0

2 11

1 1+

=

=

∑  k

 k k

11

0

1 1 0

2 11π 

λ λ λ 

µ µ µ = +

=

∑  k

 k k

π λ λ λ 

µ µ µ π 

 k

 k

 k

=−1 1   0

2 1

0

=>

(k =1, 2, 3, …)

Page 177: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 177/36922 

7 - 43© P. Raatikainen Switching Technology / 2003

Example of birth-death process

A switching system has two control computer, one on-line and onestandby. The time interval between computer failures is exponentiallydistributed with mean t f  . In case of a failure, the standby computerreplaces the failed one.A single repair facility exist and repair times are exponentially

distributed with mean t r  .What fraction of time the system is out of use, i.e., both computershaving failed?

The problem can be solved by using a three state birth-death model.

S0

λ0

µ1

S1

λ1

µ2

S2S0

1/tr 

1/tf 

S1

1/tr 

1/tf 

S2=>

7 - 44© P. Raatikainen Switching Technology / 2003

Example of birth-death process (cont.)

If  t r /  t f  = 10 , i.e. the average repair time is 10 % of the average

time between failures, then π 0 =0.009009 and both computer willbe out of service 0.9 % of the time.

S0 - both computer operable

S1 - one computer failed

S2 - both computer failed

11

1

1

1

10

2

π 

= + +  

 

 

 

   

 t

 t

 t

 t

 r

 f 

 r

 f 

π 0

2

2 2=

+ + t

 t t t t

 r

 r r f f 

=>

(probability that bothcomputers have failed)

Page 178: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 178/369

Page 179: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 179/36924 

7 - 47© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Transition probabilities

Continuous at t =0, with

Transition matrix is a function of time

{ }i s X   j s t X  P t pij   ==+= )()()(

==

→   jiif 

  jiif  t pij

 t 0

1)(lim

0

=  

)(

)()(

)( 21

1211

 t p

 t p t p

 t P

7 - 48© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Transition intensity:

(rate at which the process leaves

state  j  when it is in state  j )

(transition rate into state  j  when

the process in is state i )

)0()(   jj  j   p dt

 d  t   −=λ 

ijiijij   p p dt

 d 

 t   λ λ  == )0()(

The process, starting in state i , spends an amount of time in that

state having exponential distribution with rate λ i. It then moves to

state  j  with probability

  ji pi

ij

ij   ,∀=λ 

λ ∑

∑∑∑

=

=

==

=⇒=== n

  j

iji

i

 n

  j

ij n

  j   i

ij n

  j

ij p1

1

11

1   λ λ λ 

λ 

λ 

λ 

Page 180: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 180/36925 

7 - 49© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Chapman-Kolmogorov equations:

Since p(t) is a continuous function

)()0()0()(  2 t o t p

 dt

 d  p t p ijijij   ∆+∆+=∆

0,

,)()()(

≥∀

∈∀=+ ∑

∈  t s

S  ji s p t p s t p

S k

 kjikij

We have defined =>   )0()( ijij   p dt

 d  t   =λ 

For i ≠ j :

For i=j :

 t t o t p t p ijijijij   ∆≈∆+∆+=∆ λ λ  )()0()(  2

 t t o t p t p iiiiiiii   ∆+≈∆+∆+=∆ λ λ  1)()0()(  2

(for small ∆t)

(for small ∆t)

7 - 50© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

From Chapman-Kolmogorov equations:

∑∑≠

∆+∆=∆=∆+  j k

 kjik  jjij

 k

 kjikij   t p t p t p t p t p t p t t p   )()()()()()()(

Taking the limit as ∆t  → 0

  ∑≠

∆+∆+∆+∆+=  j k

 kjik  jjij   t o t t p t o t t p   )()()(1)(  22

λ λ 

)()()()()(  2

 t o t p t t p t p t t p k

ik

 k

 kjikijij   ∆

+∆

+=∆+ ∑∑ λ 

 t

 t o t p t p

 t

 t p t t p

 k

ik

 k

 kjik

ijij

+=

−∆+∑∑

)()()(

)()(   2

λ 

  ji t p t p dt

 d  kj

 k

ikij  ,)()(   ∀=∑ λ 

Page 181: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 181/36926 

7 - 51© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

The process is described by the system of differential equations:

  ji t p t p dt

 d  kj

 k

ikij   ,)()(   ∀=∑ λ 

which can be given in the form

  ji t P t P dt

 d ,)()(   ∀Λ=

 ti t p  j

ij   ,1)(   ∀=∑

0)1()(   ==∑  dt d  t p

 dt d 

  j

ij0)(   =∑  j

ij   t p dt

 d 

0=∑  j

ijλ  The sum of of each row of Λ is zero !

7 - 52© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Example

( )

( )

( )

+−

+−

+−

32313231

23232121

13121312

λ λ λ λ 

λ λ λ λ 

λ λ λ λ 

The sum of of each row of Λ must be zero !

S3

λ12

S2S1λ21

λ13

λ31

λ32λ23

Page 182: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 182/36927 

7 - 53© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Steady state probabilities

Must be non-negative and must satisfy  11

=∑=

 n

i

iπ 

  jij t

 t p   π =∞→

)(lim (Independent of initial state i) 

In case of continuous-time Markov chains balance equationused to determine π.For each state i , the rate at which the system leaves the state

must equal to the rate at which the system enters the state

=>   l li k ki  j  jiii   π λ π λ π λ π λ  ++=k

 j

i

l

7 - 54© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Balance equation

Steady state distribution is computed by solving this systemof equations

ii k

 k kii

i  j

ij  ∀=  

 

  

 ∑∑≠≠

π λ π λ 

ii k

 k kii

i  j

ij   ∀=   

  

 ∑∑≠≠

π λ π λ 

11

=∑=

 n

i

iπ 

Page 183: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 183/36928 

7 - 55© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

An alternative derivation of the steady-state conditions begins withthe differential equation describing the process:

Suppose that we take the limit of each side as  t → ∞

  ji t p t p dt

 d  kj

 k

ikij   ,)()(   ∀= ∑ λ 

( ) ( )∑∞→∞→

= k

 kjik t

ij t

 t p t p dt

 d λ limlim

( ) ( )∑∞→∞→

= k

 kjik t

ij t

 t p t p dt

 d λ limlim

0=∑ k

 kj kλ π 

=>

=>

=> i.e.  πΛ=0

7 - 56© P. Raatikainen Switching Technology / 2003

Markov chain modeling (cont.)

Example

0=Λπ  [ ] nπ π π π  21

=S3

λ12

S2S1

λ21

λ13

λ31

λ32

λ23

( )

( )

( )

+−

+−

+−

32313231

23232121

13121312

λ λ λ λ 

λ λ λ λ 

λ λ λ λ 

and

( )

( )

( )

=+−+

=++−

=+++−

0

0

0

33231223113

33222321112

33122111312

π λ λ π λ π λ 

π λ π λ λ π λ 

π λ π λ π λ λ 

Page 184: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 184/3691

8 - 1© P. Raatikainen Switching Technology / 2003

PDH Switches

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

8 - 2© P. Raatikainen Switching Technology / 2003

PDH switches

• General structure of telecom exchange

• Timing and synchronization• Dimensioning example

Page 185: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 185/3692 

8 - 3© P. Raatikainen Switching Technology / 2003

PDH exchange

• Digital telephone exchanges are called SPC (Stored ProgramControl) exchanges

• controlled by software, which is stored in a computer or agroup of computers (microprocessors)

• programs contain the actual intelligence to perform controlfunctions

• software divided into well-defined blocks - modularity makesthe system less complicated to maintain and expand

• Main building blocks

• subscriber interfaces and trunk interfaces

• switch fabric

• switch/call control

8 - 4© P. Raatikainen Switching Technology / 2003

Basic blocks of a PDH exchange

 … 

LOCALLOOP

   S   U   B   S   C   R   I   B   E

   R

   I   N   T   E   R   F   A   C   E

SWITCHFABRIC

   T   R   U   N   K

   I   N   T   E   R   F   A   C   E

SWITCH CONTROL

 … 

Page 186: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 186/3693 

8 - 5© P. Raatikainen Switching Technology / 2003

Switch control

• Centralized

• all control actions needed to set up/tear down a connectionare executed in a central processing unit

• processing work normally shared by a number of processors

• hierarchical or non-hierarchical processor architecture

• Distributed

• control functions are shared by a number of processing units

that are more or less independent of one another• switching device divided into a number of switching parts and

each of them has a control processor

8 - 6© P. Raatikainen Switching Technology / 2003

Switch control (cont.)

 … …

Controlprocessor Control

processor 

RP

Centralprocessor 

RP…

 … …

Centralized non-hierarchicalprocessor system

Centralized hierarchicalprocessor system

Control units usually doubled or tripledRP - Regional Processor 

Page 187: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 187/3694 

8 - 7© P. Raatikainen Switching Technology / 2003

Switch control (cont.)

Distributed controlwith independent switching parts

Switching partwith controlprocessor  …

Switching partwith controlprocessor  …

Switching partwith controlprocessor   …

Switching partwith controlprocessor   …

8 - 8© P. Raatikainen Switching Technology / 2003

Example construction of a PDHexchange

 … 

NT

SWITCHFABRIC

CONTROLPROCESSOR

 … 

ET

TRUNKINTERFACES

ET

AUX

SUBSCRIBERINTERFACES

NT

 … 

AUX - Auxiliary equipmentAT - Exchange TerminalNT - Network Terminal

ADMINISTRATIONCOMPUTER

SWITCHING &CALL CONTROL

Page 188: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 188/3695 

8 - 9© P. Raatikainen Switching Technology / 2003

Example of call control processing

DX200 / Nokia

CCSUCCSU

LSULSU

RURU

SSUSSU RU LSU CCSUSSU

STUSTU

CMCM

MM

M CM STU

CCSU - Common Channel Signaling UnitCM - Centra l MemoryLSU - Line Signaling UnitM - Marker  

RU - Registering UnitSSU - S ubscriber S tage UnitSTU - Statistics Unit

8 - 10© P. Raatikainen Switching Technology / 2003

Hierarchical control software

Administrationprograms

Call controlprograms

Signaling messageprocessing

Software systems in the control part:- signaling and call control- charging and statistics- maintenance software

Control of connections:

- calls should not be directed to faulty destinations

- faulty connections should be cleared- detected faulty connections must be reported to  far-end if possible

Page 189: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 189/3696 

8 - 11© P. Raatikainen Switching Technology / 2003

Switching part

• Main task of switching part is to connect an incoming time-slot toan outgoing one - unit responsible for this function is called agroup switch

• Control system assigns incoming and outgoing time-slot, which

are reserved by signaling, on associated physical links=> need for time and space switching

Group switch

2

2

1

1

A

B

8 - 12© P. Raatikainen Switching Technology / 2003

Group switch implementations

• Group switch can be based on a space or time switch fabric• Memory based time switch fabrics are the most common ones

- flexible constructions- due to advances in IC technology suitable also for large switch fabrics

1

2

3

...

Time-slot counter & R/W control

...k

m

Switchmemory

1

2

3

n

Controlmemory

...

...

 j (k)

123m …

Incoming frame buffer 

12 jn … …

Outgoing frame buffer 

Cyclic read

  w  r   i   t  e

  a   d   d  r  e  s  s   (   3   )

  r  e  a   d   /  w  r   i   t  e

  a   d   d  r  e  s  s   (   j   )

readaddress (k)

Cyclic write

Page 190: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 190/3697 

8 - 13© P. Raatikainen Switching Technology / 2003

Subscriber connections

 …

Remotesubscriber switch

   …

 …

Subscriber mux

Groupswitch

Local exchange …

Subscriber switch

8 - 14© P. Raatikainen Switching Technology / 2003

Subscriber and trunk interface

• Subscriber interface

• on-hook/off-hook detection, reception of dialed digits

• check of subscriber line, power supply for subscriber line

• physical signal reception/transmission, A/D-conversion• concentration

• Trunk interface

• timing and synchronization (bit and octet level) to line/clock

signal coming from an exchange of higher level of hierarchy

• frame alignment/frame generation

• multiplexing/demultiplexing

Page 191: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 191/3698 

8 - 15© P. Raatikainen Switching Technology / 2003

Example of telephone network hierarchy

Localexchange

Tandemlevel

Regionaltransit level

Nationaltransit level

Internationaltransit level

8 - 16© P. Raatikainen Switching Technology / 2003

Network synchronization

Need for synchronization

• Today’s digital telecom networks are combination of PDH andSDH technologies, i.e. TDM and TDMA utilized

• These techniques require that time and timing in the network canbe controlled, e.g., when traffic is added or dropped from a bitstream in an optical fiber or to/from a radio-transmitted signal

• The purpose of network synchronization is to enable the networknodes to operate with the same frequency stability and/orabsolute time

• Network synchronism is normally obtained by applying themaster-slave timing principle

Page 192: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 192/3699 

8 - 17© P. Raatikainen Switching Technology / 2003

Network synchronization

Methods for network synchronization

• Distribute the clock over special synchronization links- offers best integrity, independent of technological development andarchitecture of the network

• Distribute the clock by utilizing traffic links- most frequently used (master-slave network superimposed on the traffic

network)

• Use an independent clock in each node- expensive method, but standard solution in international exchanges

• Use an international navigation system in each node- GPS (Global Positioning System) deployed increasingly

- independent of technological development and architecture of network

• Combine some of the above methods

8 - 18© P. Raatikainen Switching Technology / 2003

Master-slave synchronization over transport network

Localexchange level

Transit level

International level

Remotesubscriber switch

High-stabilityreference clocks

ITU-T Recommendations G.810, G.811, G.812, G.812, G.823

Page 193: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 193/369

Page 194: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 194/36911

8 - 21© P. Raatikainen Switching Technology / 2003

Types of timing variation

• Frequency offset- steady-state timing difference - causes buffer overflows

• Periodic timing differences- jitter (periodic variation > 10 Hz)

- wander (periodic variation < 10 Hz)

• Random frequency variation cased by- electronic noise in phase-locked loops of timing devices andrecovery systems- transients caused by switching from one clock source to another

• Timing variation causes- slips (= loss of a frame or duplication of a frame) in PDH systems- pointer adjustments in SDH systems => payload jitter=> data errors

8 - 22© P. Raatikainen Switching Technology / 2003

Visualization of jitter and wander 

   J   i   t   t  e  r  a  m  p   l   i   t  u   d  e

t

Page 195: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 195/36912 

8 - 23© P. Raatikainen Switching Technology / 2003

Timing variation measures

• Time interval error  (TIE)- difference between the phase of a timing signal and phase of a

reference (master clock) timing signal (given in ns)

• Maximum time interval error (MTIE)- maximum value of TIE during a measurement period

• Maximum relative time interval error (MRTIE)- underlying frequency offset subtracted from MTIE

• Time deviation (TDEV)- average standard deviation calculated from TIE for varying window

sizes

8 - 24© P. Raatikainen Switching Technology / 2003

Maximum time interval error 

• the maximum of peak-to-peak difference in timing signal delay

during a measurement period as compared to an ideal timing signal

Measurement period ( S )

MTIE

   t   i  m   i  n  g   d  e   l  a  y

   c  o  m  p  a  r  e   d   t  o   i   d  e  a   l  s   i  g  n  a   l

Page 196: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 196/36913 

8 - 25© P. Raatikainen Switching Technology / 2003

MTIE limits for PRC, SSU and SEC

Clocksource

PRC

SSU

SEC

Time-slotinterval [ns]

25 ns0.3t  ns300 ns

0.01t  ns

25 ns10t  ns

2000 ns433t 0.2 + 0.01t  ns

250 ns100t  ns2000 ns

433t 0.2 + 0.01t  ns

Time-slotinterval [ns]

0.1 < t  < 83 s83 < t  < 1000 s

1000 < t < 30 000 st  > 30 000 s

0.1 < t  < 2.5 s2.5 < t  < 200 s

200 < t < 2 000 st  > 2 000 s

0.1 < t  < 2.5 s2.5 < t  < 20 s

20 < t < 2 000 st  > 2 000 s

ETS 300 462-3

8 - 26© P. Raatikainen Switching Technology / 2003

Occurrence of slips

Average frequency of slips

≤ 5 slips / 24h

5 slips/ 24 h …. 30 slips/ 1h

≤ 10 slips / 1h

Share of time during one year 

98.90 %

< 1 %

< 0.1 %

• Slips occur on connections whose timing differs from the timing signal used bythe exchange

• If both ends of a connection are internally synchronized to a PRC signal,theoretically slips occur no more frequently than once in 72 days

• In a reference connection a slip occurs theoretically once in 72/12 = 6 daysor if national segments are synchronized once in 720/4 = 18 days

• Slip requirement on an end-to-end connection is looser:

Page 197: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 197/36914 

8 - 27© P. Raatikainen Switching Technology / 2003

Slip calculation example

Solution:

• Timing accuracy of a PRC clock is 10-11

• Let the frequencies of the two ends be f1 and f2

• In the worst case, these frequencies deviate from the reference

clock fo by 10-11x fo and those deviations are to different directions

• Let the frequencies be f1 = (1+ 10-11) fo and f2 = (1- 10-11) fo

• Duration of bits in these networks are T1= 1/ f1 and T2= 1/ f2

Show that two networks with single frame buffers and timed fromseparate PRCs would see a maximum slip rate of one slip every72 days

8 - 28© P. Raatikainen Switching Technology / 2003

Slip calculation example (cont.)

Solution (cont.):

• During one bit interval, the timing difference is T1- T2 and after

some N  bits the difference exceeds a frame length of 125 µs and a

slip occurs => N T1- T2 = 125x10-9

=> N  = 125x10-9 /[(1/ f1 -1/ f2) ]

• Inserting f1 = (1+ 10-11) fo and f2 = (1- 10-11) fo into the above equation,

we get => N  = 125x10-9 fo (1- 10-22)/(2x 10-11)

• Multiplying N  by the duration (Tb) of one bit , we get the time (Tslip)

between slips

• In case of E1 links, fo= 2.048x106 /s and Tb = 488 ns. Dividing the

obtained Tslip by 60 (s), then by 60 (min) and finally by 24 (h) we get

the average time interval between successive slips to be 72.3 days

Page 198: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 198/36915 

8 - 29© P. Raatikainen Switching Technology / 2003

Synchronization of a switch

Synchronization sub-system in an exchange

• Supports both plesiochronous and slave mode

• Clock accuracy is chosen based on the location of the exchange inthe synchronization hierarchy

- accuracy decreases towards the leaves of the synchronization tree

• Synchronizes itself automatically to several PCM signals andchooses the most suitable of them (primary, secondary, etc.)

• Implements a timing control algorithm to eliminate

- instantaneous timing differences caused by the transmissionnetwork (e.g. switchovers - automatic replacement of faultyequipment with redundant ones)- jitter

• Follows smoothly incoming synchronization signal

8 - 30© P. Raatikainen Switching Technology / 2003

Synchronization of a switch (cont.)

Exchange follows the synchronization signal

• Relative error used to set requirements- maximum relative time interval error MRTIE≤1000 ns (S≥ 100s)

• Requirement implies how well the exchange must follow thesynchronization signal when the input is practically error free

• When none of the synchronization inputs is good enough, theexchange clock automatically switches over to plesiochronousoperation

• In plesiochronous mode MRTIE≤ (aS  +0.5bS 2 + c) ns

• Timing system monitors all incoming clock signals and when aquality signal is detected, the system switches over back to slavemode (either manually by an operator command or automatically)

Page 199: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 199/36916 

8 - 31© P. Raatikainen Switching Technology / 2003

Stability of an exchange clock

• Clock stability is measured by aging (=b)- temperature stabilized aging in the order of n  x 10-10 /day

• MRTIE ≤ (aS  +0.5bS 2 + c) ns- S = measurement period- a = accuracy of the initial setting of the clock- b = clock stability (measured by aging)- c = constant

Transit node clock

0.5 - corresponds to an initialfrequency shift of 5x10-10

1.16x10-5 - corresponds 

to aging of 10-9 /days

1000

Local node clock

10.0 - corresponds to aninitial frequency shift of 1x10-8

2.3x10 -4 - correspondsto aging of 2x10-8 

1000

8 - 32© P. Raatikainen Switching Technology / 2003

MRTIE in an exchange(plesiochronous mode)

Duration of a time-slot in a PCM-signal is 3.9 µs and duration of a bit is 488 ns

1E+0

1E+1

1E+2

1E+3

1E+4

1E+5

1E+6

1E+7

1E+8

1E+9

1E+10

1E+2 1E+3 1E+4 1E+5 1E+6 1E+7

   M   R   T   I   E  n  s

Observation time (S )

Transit exchange

Local exchange

Page 200: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 200/36917 

8 - 33© P. Raatikainen Switching Technology / 2003

Example of SRAM based PDHswitch fabric

Time-interchangebased 64 PCM switch

4xE1

2M 8M

4xE2 4xE3

34M 140M

 …

   E

   4  =   >   6   4  x   E   1   d  e  m  u  x

   6   4  x   E   1  =   >   E   4  m  u  x

 …

8 - 34© P. Raatikainen Switching Technology / 2003

Example of SRAM based PDHswitch fabric (cont.)

Memory size and speed requirement:

• Switch memory (SM) and control memory (CM) both are single chipsolutions

• Size of both SM and CM ≥ 64x32 octets = 2048 octets• Number of SM write and read cycles during a frame interval (125 µs)

is 2x64x32 = 4096

• Access cycle of SM should be ≤ 125 µs/4096 = 30,5 ns

• Number of CM write and read cycles during a frame interval (125 µs)is 1x64x32 = 2048

• Access cycle of CM should be ≤ 125 µs/2048 = 61 ns

Page 201: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 201/36918 

8 - 35© P. Raatikainen Switching Technology / 2003

PDH bit rates and related bit/octet times

Hierarchylevel

E1/2M

E2/8M

E3/34M

Time-slotinterval [ns]

3906

947

233

Bit interval[ns]

488

118

29

E4/140M 57.4 7.2

• When time-slots turn into parallel form (8 bits in parallel) memoryspeed requirement decreased by a factor of 8

• Present day memory technology enables up to 256 PDH E1 signalsto be written to and read from a SRAM memory on wire speed

8 - 36© P. Raatikainen Switching Technology / 2003

Properties of full matrix switches

Pros

• strict-sense non-blocking

• no path search - a connection can always be written into thecontrol memory if requested output is idle

• multi-cast capability

• constant delay

• multi-slot connections possible

Cons

• switch and control memory both increase in square of the numberof input/outputs

• broadband - required memory speed may not be available

Page 202: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 202/36919 

8 - 37© P. Raatikainen Switching Technology / 2003

Make full use of available memory speed

• At the time of design, select components that

- give adequate performance

- will stay on the market long enough

- are not too expensive (often price limits the use of the fastest components)

• To make full use of available memory speed, buses must be fast enough

• When increasing required memory speed, practical bus length decreases(proportional to inverse of speed)

Length of a bus

Bus bit-rate

5 ns 20 ns

$/SRAM

DRAM: 40 ... 70 ns

Bus Bit-rate

Memory speed

8 - 38© P. Raatikainen Switching Technology / 2003

Power consumption - avoid heating

problem

• Power consumption of an output gate is a function of- inputs connected to it (increased number of inputs => increased power

consumption)

- bit rate/clock frequency (higher bit rate => increased power consumption

- bus length (long buses inside switch fabric => increased power consumption

and decreased fan-out)• Increase in power consumption => heating problem

• Power consumption and heating problem can be reduced, e.g. by using lowervoltage components (higher resolution receivers)

Receiver’s resolution

   P  o  w  e  r

Bus length

   F  a  n  -  o  u   t

   P  o  w  e  r

Fan-out

Page 203: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 203/36920 

8 - 39© P. Raatikainen Switching Technology / 2003

Logical structure of a full matrix switch

1

2

3

N

1

2

3

N

 . . .

 . . .

Feasible SMwith availablecomponents

Feasible SMwith availablecomponents

Feasible SMwith availablecomponents

 . . .

Replication of inputs Multiplexed inputs

N = 2n

8 - 40© P. Raatikainen Switching Technology / 2003

Example of a matrix switch (DX200)

Read

32x64=2k

Address

8

0

7  . . .

16

Wr 

Fan-out=32

Control & switching memory card

    .    .    .

0 63

S/P

Bus buffer 

0 63

S/P

0 63

S/P

0 63

S/P

   P   /   S

0

63

CMSM SM SMSM

   P   /   S

0

63

CMSM SM SMSM

   P   /   S

0

63

CMSM SM SMSM

   P   /   S

0

63

CMSM SM SMSM

Page 204: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 204/36921

8 - 41© P. Raatikainen Switching Technology / 2003

Example of a matrix switch (cont.)

• S/P (Serial/Parallel conversion) - incoming time-slots are turned intoparallel form to reduce the speed on internal buses

• P/S (Parallel/Serial conversion) - parallel form output signals convertedback to serial form

• 64 PCM S/P-P/S pairs implemented on one card, which is practicalbecause PCMs are bi-directional

• One switch block can serve max 4 S/P-P/S pairs - which is chosenbased on required capacity (64, 128, 192 or 256 E1/PCMs)

• One S/P+P/S pair feeds max 8 parallel switch blocks - chosen based on

the required capacity in the installation (n * 256 E1/PCM’s)• Max size of the example DX200-system fabric is 2048 E1/PCM’s

• Currently, a bigger matrix ( 8K E1/PCM’s) is available, slightly differentSRAMs are needed, but principle is similar

8 - 42© P. Raatikainen Switching Technology / 2003

Example of a matrix switch (cont.)

• A time-slot is forwarded from an S/P to all parallel switch blocksand in each switch block it is written to all SMs along the verticalbus

• A single time-slot replicated into max 4x8=32 locations• Data in CMs used to store a time-slot in correct positions in SMs

• CM also includes data to read a correct time-slot to be forwardedto each output time-slot on each output E1 link

• CM includes a 16-bit pointer to a time-slot to be read

 – 2 bits of CM content point to an SM chip and

 – 5 + 6 = 11 bits point to a memory location on an SM chip

 – remaining 3 bits point to (source) switch block

Page 205: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 205/36922 

8 - 43© P. Raatikainen Switching Technology / 2003

Example of a matrix switch (cont.)

• Number of time-slots to be switched during a frame (125 µs): - 8x4x64x32 = 65 536 time-slots (= 64 kbytes)

• Each time-slot stored in 4 SMs in each of the 8 switch blocks=> max size of switch memory 8x4x65 536 = 2097152 (= 2 Mbytes)

• Every 32nd memory location is read from SM in a max size switch=> average memory speed requirement < 31 ns (less than theworst case requirement 64x32 write and 64x32 read operationsduring a 125 µs period)

• Control memory is composed of 4x4 control memory banks in eachof the 8 switch blocks and each memory bank includes 2.048kwords (word= 2 bytes) for write and 2.048 kwords for read control,i.e. max CM size is 8x4x4x8kbytes = 1048576 bytes (= 1 Mbytes)

8 - 44© P. Raatikainen Switching Technology / 2003

Growth of matrix

256 PCM

512 PCM

Page 206: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 206/369

L9 - 1© P. Raatikainen Switching Technology / 2005

ATM Switches

Switching Technology S38.165http://www.netlab.hut.fi/opetus/s38165

L9 - 2© P. Raatikainen Switching Technology / 2005

ATM switches

• General of ATM switching

• Structure of an ATM switch

• Example switch implementations

• Knockout switch

• Abacus

• Dimensioning example

Page 207: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 207/369

L9 - 3© P. Raatikainen Switching Technology / 2005

General of ATM switching

• ATM switches correspond to layer 2 in the OSI reference modeland this layer can roughly be divided into a higher and lower layer:

 – higher layer = ATM Adaptation Layer (AAL)

 – lower layer = ATM layer

Layer 1

Error recovery & flow control

Layer 1

Layer 2 (L) Layer 2 (L)

Layer 1

Layer 2 (L)Layer 2 (H)

Limited error detection Layer 1

Limited error detection

Network edge Switching node Network edge

Error & congestioncontrol

Error & congestioncontrol

Layer 2 (L)Layer 2 (H)

Layer 1

Error recovery & flow control

Layer 1

Layer 2 (L) Layer 2 (L)

Layer 1

Layer 2 (L)Layer 2 (H)

Limited error detection Layer 1

Limited error detection

Network edge Switching node Network edge

Error & congestioncontrol

Error & congestioncontrol

Layer 2 (L)Layer 2 (H)

L9 - 4© P. Raatikainen Switching Technology / 2005

ATM Adaptation Layer 

• AAL offers different service classes for user data – delay, bit rate and connection type (connectionless or circuit

emulation) are the basic attributes of the service classes

• SAR (Segmentation and Reassembly) sub-layer for segmentation

of variable length user data packets into fixed-size ATM cell

payloads and at reception reassembly of ATM cell payload into

user packets

• CS (Convergence Sub-layer) maps specific user data

requirements onto ATM transport network

AAL maps higher-layer information into ATM cells to be transportedover an ATM network. At reception, AAL collects information fromATM cells for delivery to higher layers.

Page 208: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 208/369

L9 - 5© P. Raatikainen Switching Technology / 2005

ATM service classes

Connec-tionless

Connection- orientedConnection mode

VariableConstantBit rate

AAL3/4or ALL5

AAL3/4or ALL5AAL2AAL1ALL (s)

IP, SMDSFrameRelayX.25

Packetvideo,audio

E1,nx64 kbit/semulation

Examples

Not requiredRequiredTiming relation betweensource and destination

Class DClass CClass BClass AAttribute

Service class

L9 - 6© P. Raatikainen Switching Technology / 2005

ATM cell payloadATM header

ATM Adaptation layer 1 (AAL1)

SAR-PDU header User informationStructurepointer

SAR-PDU header User information

P format

Non-P format

CS ParitySequencecount CRC control

Seq. number field Seq. numberprotection

1 octet 1 octet 46 octets

SAR-PDU - Segmentation and Reassembly Packet Data UnitCS - Convergence Sub-layerCRC - Cyclic Redundancy Check

Page 209: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 209/369

L9 - 7© P. Raatikainen Switching Technology / 2005

ATM Adaptation layer 2 (AAL2)

CID - Connection IdentificationHEC - Header Error CheckLI - Length IndicatorLLC - Logical Link ControlRES - Reserved

LLC packetheader CID=1

User information

3 octets < 61 octets

CID8 bits

LI6 bits

RES5 bits

HEC5 bits

LLC packetheader CID=2

User information . . .

ATM cell payloadATM

headerSTF ATM cell payload

ATMheader

STFATM

headerSTF

OSF6 bits

SN1 bit

Parity1 bit OSF - Offset

SN - Sequence NumberSTF - Start Field

L9 - 8© P. Raatikainen Switching Technology / 2005

ATM header ATM cell payload

ATM Adaptation layer 3/4 (AAL3/4)

SAR-PDUheader

SAR-PDU payload Pad

2 octets 2 octets

SAR-PDUtrailer

4 - 44 octets

48 octets

SARtype MIDSAR-

SNSAR-PDU

CRC

SAR-PDUUser info.

length

2 bits 4 bits 10 bits 6 bits 10 bits

AAL3/4 SAR PDU

CS-PDUheader

CS-PDU user information Pad

CS-PDUtype

BASize

4 octets < 65 535 octets 4 octets

CS-PDUtrailer

0-3octets

BtagProtocolcontrol

CS UserInfo. lengthETag

AAL3/4 CPCS PDU

CS - Convergence Sub-layerCPCS - Common Part CSCRC - Cyclic Redundancy CheckMID - Message IdentifierSAR - Segmentation and ReassemblyPDU - Packet data UnitBtag - Beginning tagBAsize - Buffer Allocation tagEtag - Ending tag

Page 210: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 210/369

L9 - 9© P. Raatikainen Switching Technology / 2005

ATM Adaptation layer 5 (AAL5)

CS-PDU payload Pad

4 octets

CRC

   0 

  -   4   7 

  o  c   t  e   t  s

UU CPI LEN

< 65 535 octets    2   o

  c   t  e   t  s

   1   o

  c   t  e   t

   1   o

  c   t  e   t

Pad - Padding octetsUU - AAL layer user-to-user indicatorCPI - Common part indicatorLEN - Length indicatorCRC - Cyclic redundancy Check

ATMheader

ATM cell payloadATM

headerATM cell payload . . .

L9 - 10© P. Raatikainen Switching Technology / 2005

ATM layer 

• multiplexing/demultiplexing of cells belonging to different virtual

connections

• translations of inbound VPIs/VCIs to outbound VPIs/VCIs

• cell header generation for data received from AAL and cell header

extraction when a cell is delivered to AAL

• flow control

ATM layer (common to all services) offers transport of data in fixed-size cells and also defines the use of virtual connections(VPs and VCs)

Page 211: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 211/369

L9 - 11© P. Raatikainen Switching Technology / 2005

General of ATM switching (cont.)

• ATM is a connection-oriented transport concept

• an end-to-end connection (virtual channel) established prior totransfer of cells

• signaling used for connection set up and release

• data transferred in fixed 53 octets long cells (5 octets forheader and 48 octets for payload)

• Cells routed based on two header fields

• virtual path identifier (VPI) - 8 bits for UNI and 12 bits for NNI

• virtual channel identifier (VCI) - 16 bits for UNI and NNI

• combination of VPI and VCI determines a specific virtualconnection between two end-points

L9 - 12© P. Raatikainen Switching Technology / 2005

ATM cell structure

ATMheader 

ATMheader  Cell payloadCell payload

5 octets 48 octets

GFCGFC

VPIVPI

VPIVPI

VCIVCI

VCIVCI

VCIVCI

PTIPTI

CPLCPL

HECHEC

ATM header for UNI

UNI - User Network InterfaceNNI - Network-to-Network InterfaceVPI - Virtual Path Identifier VCI - Virtual Channel Identifier GFC - Generic Flow ControlPTI - Payload Type Identifier CPL - Cell Loss PriorityHEC - Header Error Control

VPIVPI

VPIVPI

VCIVCI

VCIVCI

VCIVCI

PTIPTI

CPLCPL

HECHEC

ATM header for NNI

HEC = 8 x (header octets 1 to 4) / (x8 + x2 + x + 1)

Page 212: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 212/369

L9 - 13© P. Raatikainen Switching Technology / 2005

General of ATM switching (cont.)

• VPI/VCI is determined on a per-link basis=> VPI/VCI on an incoming link is replaced (at the ATM switch) withanother VPI/VCI for an outgoing link=> number of possible paths in an ATM network increasedsubstantially (compared to having end-to-end VPI/VCIs)

• Each ATM switch includes a Routing Information Table (RIT), whichis used in mapping incoming VPI/VCIs to outgoing VPI/VCIs

• RIT includes:

• old VPI/VCI

• new VPI/VCI

• output port address

• priority

L9 - 14© P. Raatikainen Switching Technology / 2005

General of ATM switching (cont.)

• When an ATM cell arrives to an ATM switch, VPI/VCI in the 5-octet cellheader is used to point to a RIT location, which includes

• new VPI/VCI to be added to an outgoing cell

• output port address indicating to which port the cell should be routed

• priority field allowing the switch to selectively send cells to outputports or discard them (in case of buffer overflow)

• Three routing modes:

• unicast - log2N bits needed to address a destination output port

• multi-cast - N  bits needed to address destined output ports

• broadcast - N  bits needed to address destined output ports

• In multi-cast/broadcast case, a cell is replicated into multiple copies andeach copy is routed to its intended output port/outbound VC

Page 213: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 213/369

Page 214: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 214/369

L9 - 17© P. Raatikainen Switching Technology / 2005

VPI/VCI translation (cont.)

• VPI/VCI replacement usually takes place at the output ports=> RIT split into two parts

• input RIT - includes old VPI/VCI and N-bit output port address

• output RIT - includes log2N -bit input port address, old VPI/VCIand new VPI/VCI

• Since cells from different input ports can arrive to the same output

port and have the same old VPI/VCI, the input port address is

needed to identify uniquely different connections

L9 - 18© P. Raatikainen Switching Technology / 2005

ATM switches

• General of ATM switching

• Structure of an ATM switch

• Example switch implementations

• Knockout switch

• Abacus

• Dimensioning example

Page 215: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 215/369

L9 - 19© P. Raatikainen Switching Technology / 2005

Functional blocks of an ATM switch

Main blocks

• Line interface cards (LICs), which implement input and outputport controllers (IPCs and OPCs)

• Switch fabric provides interconnections between input andoutput ports

• Switch controller , which includes

- a call processor for RIT manipulations- control processor to perform operations, administration andmaintenance (OAM ) functions for switch fabric and LICs

L9 - 20© P. Raatikainen Switching Technology / 2005

Main functional blocks of an ATM switch

 …

IPC

SWITCHFABRIC

SWITCHCONTROLLER

 …

OPC

LIC

SWITCHING &CONNECTION

CONTROL

IPC OPC

LIC

LIC - Line Interface CardIPC - Input Port Controller OPC - Output Port Controller 

Page 216: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 216/369

L9 - 21© P. Raatikainen Switching Technology / 2005

Functions of input port controller • Line termination and reception of incoming line signal

• Conversion of optical signal to electronic form if needed

• Decoding/descrambling of line/block coded or scrambled line signal

• Transport frame, e.g. SDH or PDH frame, processing

• Extraction of cell header for processing

• Storing of cell payload (or whole cells) to buffer memory

• HEC processing=> discard corrupted cells

=> forward headers of uncorrupted cells to routing process• Generation of a new cell header (if RIT only at input) and routing tag

to be used inside switch fabric

• Cell stream is slotted and a cell is forwarded through switch fabric ina time-slot

L9 - 22© P. Raatikainen Switching Technology / 2005

Functions of output port controller 

• Cells received from switch fabric are stored into output buffer

• Generation of a new cell header (if RIT also at output)

• One cell at a time is transferred to the outgoing line interface

• If no buffering available then contention resolution=> one cell transmitted and others discarded

• If buffering available and priorities supported then higher prioritycells forwarded first to transport frame processing

• Cell encapsulation into transport frames, e.g. SDH or PDH frame

• Line/block encoding or scrambling of outgoing bit stream

• Conversion of electronic signal to optical form (if needed)

• Transmission of outgoing line signal

Page 217: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 217/369

L9 - 23© P. Raatikainen Switching Technology / 2005

Input and output controller blocksInput controller blocks:

48

SDH

W Z 10

RIT

 … … …

+

W

5

Z

Old VPI/VCINew VPI/VCI

Output port

Fromnetwork

To switchfabric

Buffer 10

Z 10

STM-1 frame

W. . . . . .

O/E

SDH E/O

ZFromswitchfabric To network

Buffer Z

Output controller blocks:

STM-1 frame

Z. . . . . .

L9 - 24© P. Raatikainen Switching Technology / 2005

Switch control

• Switch controller implements functions of ATM management andcontrol layer

• Control plane

• responsible for establishment and release of connections, which

are either pre-established (PVCs) using management functions orset up dynamically (SVCs) on demand using signaling, such asUNI and PNNI signaling

• signaling/management used to update routing tables (RITs) in theswitches

• implements ILMI (Integrated Local Management Interface), UNIsignaling and PNNI routing protocols

• processes OAM cells

Page 218: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 218/369

L9 - 25© P. Raatikainen Switching Technology / 2005

Switch control (cont.)

• ILMI protocol uses SNMP (Simple Network Management Protocol) toprovide ATM network devices with status and configurationinformation related to VPCs, SVCs, registered ATM addresses andcapabilities of ATM interfaces

• UNI signaling specifies the procedures to dynamically establish,maintain and clear ATM connections at UNI

• PNNI protocol provides the functions to establish and clearconnections, manage network resources and allow network to be

easily configurable

• Management plane

• provides management functions and capabilities to exchangeinformation between the user plane and control plane

L9 - 26© P. Raatikainen Switching Technology / 2005

ATM protocol reference model

Terminal TerminalNode Node

Physical layer 

ATM layer 

Management plane

ATM adaptation layer 

Higher layer protocols Higher layer protocols

Control plane User plane L  a y er m an a g em en t  

P l   an em an a g em en t  

Page 219: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 219/369

L9 - 27© P. Raatikainen Switching Technology / 2005

Switch fabric

• Provides interconnections between input and output interfaces

• ATM specific requirements

• switching of fixed length cells

• no regular switching pattern between an input-output port pair,i.e., time cap between consecutive cells to be switched from aninput to a specific output varies with time

• Early implementations used time switching principle (mostly based

on shared media fabrics) - easy to use, but limited scalability• Increased input rates forced to consider alternative solutions

=> small crossbar fabrics were developed=> multi-stage constructions with self-routing reinvented

L9 - 28© P. Raatikainen Switching Technology / 2005

Cell routing through switch fabric

• Cells usually carried through switch fabric in fabric specific frames

• Carrier frames include, e.g. header, payload and trailer fields

• Header field sub-divided into

• source port address

• destination port address

• flow control sub-field (single/multi-cast cell, copy indication, etc.)

• Payload field carries an ATM cell (with or without cell header)

• Trailer is usually optional and implements an error indication/correction sub-field, e.g. parity or CRC

Frameheader 

Frame payloadFrametrailer 

General structure of a cell carrier frame

Page 220: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 220/369

L9 - 29© P. Raatikainen Switching Technology / 2005

ATM switching and buffering

• Due to asynchronous nature of ATM traffic, buffering is an importantpart of an ATM switch fabric design

• A number of different buffering strategies have been developed

• input buffering

• output buffering

• input-output buffering

• internal buffering

• shared buffering• cross-point buffering

• recirculation buffering

• multi-stage shared buffering

• virtual output queuing buffering

L9 - 30© P. Raatikainen Switching Technology / 2005

Buffering strategies

Switchfabric

 . . .

 . . .

Input buffered

Switchfabric

 . . .

 . . .

Output buffered

Switchfabric

 . . .

 . . .

Input-output buffered

Internally buffered

Sharedmemory

Switchfabric

 . . . Switch

fabric  . . .

Shared buffer 

Page 221: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 221/369

L9 - 31© P. Raatikainen Switching Technology / 2005

Buffering strategies (cont.)Cross-point buffered

Switchfabric

 . . .

 . . .

 . . .

Recirculation buffered

 . . .

 . . .

 . . .

 . . .

 . . .

 . . .  . .

 .

Multi-stage shared buffer 

Switchfabric

 . . .

 . . .

 . . .

 . . .

Virtual output queuing

L9 - 32© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Input buffered switches

• Suffers from HOL blocking => throughput limited to 58.6 % of themaximum capacity of a switch (under uniform load)

• Windowing technique can be used to increase throughput, i.e.multiple cells in each input buffer are examined and considered fortransmission to output ports (however only one cell transmitted ina time-slot)=> window size of two gives throughput of 70 %=> windowing increases implementation complexity

Switchfabric

 . . .

 . . .

Input buffered

Page 222: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 222/369

L9 - 33© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Output buffered switches

• No HOL blocking problem

• Theoretically 100 % throughput possible

• High memory speed requirement, which can be alleviated byconcentrator=> output port count reduced=> reduced memory speed requirement

=> increased cell loss rate (CLR)• Output buffered systems largely used in ATM switching

Switchfabric

 . . .

 . . .

Output buffered

L9 - 34© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Input-output buffered switches

• Intended to combine advantages of input and output buffering- in input buffering, memory speed comparable to input line rate

- in output buffering, each output accepts up to L cells (1≤L≤N)

=> if there are more than L cells destined for the same output,excess cells are stored in input buffers

• Desired throughput can be obtained by engineering the speed upfactor L, based on the input traffic distribution

• Output buffer memory needs to operate at L times the line rate=> large-scale switches can be realized by applying input-outputbuffering

• Complicated arbitration mechanism required to determine, whichL cells among the N possible HOL cells go to output port

Page 223: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 223/369

L9 - 35© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Internally buffered switch

• Buffer implemented within switch blocks

• Example is a buffered banyan switch

• Buffers used to store internally blocked cells=> reduced cell loss rate

• Suffers from low throughput and high transfer delay

• Support of QoS requires schedulingand buffer management schemes=> increased implementation cost

Internally buffered

L9 - 36© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Shared-buffer switches

• All inputs and outputs have access to a common buffer memory

• All inputs store a cell and all outputs retrieve a cell in a time-slot=> high memory access speed

• Works effectively like an output buffered switch=> optimal delay and throughput performance

• For a given CLR shared-buffer switches need less memory thanother buffering schemes => smaller memory size reduces costwhen switching speed is high (∼ Gbits/s)

• Switch size is limited by the memory access speed (read/write time)

• Cells destined for congested outputs can occupy shared memoryleaving less room for cells destined for other outputs (solved byassigning minimum and maximum buffer capacity for each output)

Sharedmemory

Switchfabric

 . . . Switch

fabric  . . .

Sharedbuffer 

Page 224: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 224/369

L9 - 37© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Cross-point buffered switches

• A crossbar switch with buffers at cross-points

• Buffers used to avoid output blocking

• Each cross-point implements a buffer and an address filter

• Cells addressed to an output are accepted to a corresponding buffer

• Cells waiting in buffers on the same column are arbitrated to theoutput port one per time-slot

• No performance limitation as with input buffering• Similar to output queuing, but the queue for each output is distributed

over a number (N) of buffers => total memory space for a certainCLR > CLR for an output buffered system

• Including cross-point memory in a crossbar chip, limits the number ofcross-points

Cross-point buffered

L9 - 38© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Recirculation buffered switches

• Proposed to overcome output port contention problem

• Cells that have lost output contention are stored incirculation buffers and they content again in the next time-slot

• Out-of-sequence errors avoided by assigning priority value to cells

• Priority level increased by one each time a cell loses contention=> a cell with the highest priority is discarded if it loses contention

• Number of recirculation ports can be engineered to fulfill requiredcell loss rate (CLR = 10-6 at 80 % load and Poisson arrivals=> recirculation port count divided by input port count = 2.5)

• Example implementations Starlite switch and Sunshine switch- Sunshine allows several cells to arrive to an output in a time-slot=> dramatic reduction of recirculation ports

Switchfabric

 . . .

 . . .

 . . .

Recirculationbuffered

Page 225: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 225/369

L9 - 39© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Multi-stage shared buffer switches

• Shared buffer switches largely used in implementing small-scaleswitches - due to sufficiently high throughput, low delay and highmemory utilization

• Large-scale switches can be realized by interconnecting multipleshared buffer switch modules=> system performance degraded due to internal blocking

• In multi-stage switches, queue lengths may be different in the 1stand 2nd stage buffers and thus maintenanceof cell sequence at the output module may bevery complex and expensive

 . . .

 . . .

 . . .

 . . .

 . . .

 . . .  . .

 .

Multi-stage shared buffer 

L9 - 40© P. Raatikainen Switching Technology / 2005

ATM switching and buffering (cont.)

Virtual output queuing switches

• A technique to solve HOL blocking problem in input bufferedswitches

• Each input implements a logical buffer for each output (in acommon buffer memory)

• HOL blocking reduced and throughput increased

• Fast and intelligent arbitration mechanism required, because allHOL cells need to be arbitrated in each time-slot=> arbitration may become the system bottleneck

Switchfabric . .

 . . . .

 . . .

 . . .

Virtual output queuing

Page 226: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 226/369

L9 - 41© P. Raatikainen Switching Technology / 2005

Design criteria for ATM switches

• Several criteria need to be considered when designing an ATMswitch architecture

• A switch should provide bounded delay and small cell lossprobability while achieving a maximum throughput (close to 100%)

• Capacity to support high-speed input lines (which possibly deploydifferent transport technologies, e.g. PDH or SDH)

• Self-routing and distributed control essential to implement large-scale switches

• Maintenance of correct cell sequence at outputs

L9 - 42© P. Raatikainen Switching Technology / 2005

Performance criteria for ATM switches

• Performance defined for different quality of service (QoS) classes

• Performance parameters:

• cell loss ratio (CLR)

• cell transfer delay (CTD)• two-point cell transfer delay variation (CDV)

Performance parameter CLP QoS1 QoS3 QoS4

Cell loss ratio 0 < 10-10 <10-7 <10-7

Cell loss ratio 1 N/S N/S N/SCell transfer delay (99th percentile) 1/0 150 µµµµs 150 µµµµs 150 µµµµsCell delay variation (10-10 quantile) 1/0 250 µµµµs N/S N/SCell delay variation (10-7 quantile) 1/0 N/S 250 µµµµs 250 µµµµs

N/S - not specified

Bellcore recommended performance requirements 

Page 227: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 227/369

L9 - 43© P. Raatikainen Switching Technology / 2005

Distribution of cell transfer delay• Figure below shows a typical cell transfer delay distribution through a

switch node

• Fixed delay is attributed to table lookup delay and other cell headerprocessing (e.g. HEC processing)

• For example:- Prob(CTD > 150 µs) < 1 - 0.99 => a = 0.01 and x = 150 µs (QoS1, 3 and 4)

- Prob(CTD > 250 µs) < 10-10 => a = 10-10 and x = 250 µs (QoS1)

f ixed density peak- to- peak CDV

maximum CDV

Probability

density

Cell transfer

delay

1-   a  xa 

L9 - 44© P. Raatikainen Switching Technology / 2005

Cell processing times at differenttransmission speeds

100 ns

1 us

10 us

100 us

1 ms

10 ms

100 ms

9.6 64 384 2 10 34 100 155 622 2.5

kbit/s Mbit/s Gbit/s

Link speed

   P  r  o  c  e  s  s   i  n  g   t   i  m

  e221 µµµµs/E1 2.83 µµµµs/STM-1

708 ns/STM-4

177 ns/STM-16

Page 228: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 228/369

L9 - 45© P. Raatikainen Switching Technology / 2005

Delay and jitter components

1

2

3

4

Encapsulation/decapsulation delay

Admission control (smoothing)

Queuing delay

Switching delay

5

6

7

Transmission delay

Propagation delay

Reassembly (playtime) delay

No contribution to jitter 

Contribution to jitter 

User 

A

Node

1

Node

2

Node

n

User 

B

1 2 3 45

6

751

6 6 6

2 3 4 513 311 2 3 4 51 1 1

L9 - 46© P. Raatikainen Switching Technology / 2005

ATM switches

• General of ATM switching

• Structure of an ATM switch

• Example switch implementations

• Knockout switch

• Abacus

• Dimensioning example

Page 229: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 229/369

L9 - 47© P. Raatikainen Switching Technology / 2005

ATM switching fabric implementations

A lot of different switching network architectures havebeen experimented in ATM switch fabrics :

• Batcher-banyan based switches, e.g. Sunshine

• Clos network based switches, e.g. Atlanta

• Crossbar/crosspoint switches, e.g. TDXP (Tandem-Crosspoint)

• Ring and single/dual bus based switches

Most advanced ATM switching concepts are switchingnetwork independent, e.g. Knockout and Abacus

L9 - 48© P. Raatikainen Switching Technology / 2005

Knockout switch

• Output buffered switches largely used in ATM networks

• Capacity of output buffered switches limited by memory speed

• Problem solved by limiting the number of cells allowed to an outputduring each time-slot and excess cells discarded

=> knockout principle

• How many cells to deliver to an output port during each time-slot=> this number can be determined for a given cell loss rate (CLR),e.g. 12 time-slots for CLR=10-10, independent of switch size

• Memory speed seemed to be no more a bottleneck, however nocommercial switch implementations appeared- inputs are supposed to be uncorrelated (not the case in real networks)- idea of discarding cells not an appealing one

• Knockout principle has been basis for various switch architectures

Page 230: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 230/369

L9 - 49© P. Raatikainen Switching Technology / 2005

Knockout principle

• N input lines each implement a broadcast input bus, which isconnected to every output block

• An output block is composed of cell filters that are connected to anN-to-L concentrator, which is further connected to a shared buffer

• No congestion between inputs and output blocks

• Congestion occurs at the interfaces of outputs (inside concentrator)

• k cells passing through cell filters enter the concentrator and

- if k≤≤≤≤L then all cells go to shared buffer- if k>L then L cells go to shared buffer and k-L cells are discarded

• Shared buffer includes a barrel shifter and L output (FIFO) buffers- barrel shifter stores cells coming from concentrator to FIFOmemories in round robin fashion=> complete sharing of output FIFO buffers

L9 - 50© P. Raatikainen Switching Technology / 2005

Knockout switch interconnectionarchitecture

12

N

...

1 2

...

N

   I  n  p  u   t  s

Outputs

Broadcast buses

Businterfaces

Page 231: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 231/369

L9 - 51© P. Raatikainen Switching Technology / 2005

Knockout switch bus interface

Barrel shifter 

Cellbuffers

Output

Concentrator 

Sharedbuffer 

...

1 2 3 4 N-1 N

...Cell

filters

1 2 L

...

1 2 L

Inputs

L9 - 52© P. Raatikainen Switching Technology / 2005

Operation of barrel shifter 

A

Barrel shifter

B

C

...

...A

B

C.........

...

...

...

BufferAt time T

D

E

F

G

H

I

J

...

...I

J

A

B

C

D

E

F

G

H

...

...

...

...

...

...

Barrel shifter BufferAt time T+1

Page 232: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 232/369

L9 - 53© P. Raatikainen Switching Technology / 2005

Example construction of concentrator 

Outputs

Input

D

D

D

D

D

D

D

D

D

D

D

D

D

D

1 2 3 4

An 8-to-4 concentrator 

L9 - 54© P. Raatikainen Switching Technology / 2005

Cell loss probability

• In every time-slot there is a probability ρρρρ that a cell arrives at an input

• Every cell is equally likely destined for any output

• Pk denotes probability of k cells arriving in a time-slot to the sameoutput, which is a binomial distribution

, k = 0,1, …, N

• Probability of a cell being dropped in N-to-L concentrator is given by

• Taking the limit as N →→→→ ∞∞∞∞ and with some manipulation

P N

k N1

Nk

k N k

====             

               

      −−−−   

        

   

−−−−ρρρρ ρρρρ

((((   ))))P(cell loss) k - LN

k N Nk L 1

Nk N-k

====     

       

                    −−−−

      

       

==== ++++

∑∑∑∑1

1ρρρρ

ρρρρ ρρρρ

P(cell loss)L e

k!

e

L!

k -

k=0

L L -

==== −−−−   

   

    

      −−−−   

   

    

      ++++∑∑∑∑1 1

ρρρρ

ρρρρ ρρρρρρρρ ρρρρ

Page 233: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 233/369

L9 - 55© P. Raatikainen Switching Technology / 2005

Cell loss probability (cont.)

Cell loss probability for some switch sizes(90% load)

Number of concentrator outputs, L

1 2 3 4 5 6 7 8 9 10 11

   C  e   l   l   l  o  s  s  p  r  o   b  a   b   i   l   i   t  y

10-2

10-4

10-6

10-8

10-10

10-12

100

N = 16N = 32

N = 64

N = ∞∞∞∞

Load = 100 %

Load = 90 %Load = 80 %Load = 70 %Load = 60 %

Number of concentrator outputs, L

1 2 3 4 5 6 7 8 9 10 11

   C  e   l   l   l  o  s  s  p  r  o   b  a   b   i   l   i   t  y

10-2

10-4

10-6

10-8

10-10

10-12

100

Cell loss probability for some load values(N = ∞∞∞∞)

L9 - 56© P. Raatikainen Switching Technology / 2005

Channel grouping

Channel grouping principle used in modular two-stage networks

• A group of outputs treated identically in the first stage

• A cell destined for an output of a group is routed to any output (atthe first stage), which is connected to that group at the second stage

• First stage switch routes cells to proper output groups and secondstage switches route cells to destined output ports

Cell to 6

1st stage

Cell to 1

Cell to 3

2nd stage

0123

4567

Cell to 4

Page 234: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 234/369

L9 - 57© P. Raatikainen Switching Technology / 2005

Channel grouping (cont.)

Asymmetric switch with line extension ratio of KM/N

• Output group of M output ports corresponds to a single outputaddress for the 1st stage switch

• At any given time-slot, M cells at most can be cleared from aparticular output group (one cell on each output port)

NxKMswitch

1

2

N

MxMswitch

MxM

switch

 . . .  . .

 .

M M

M M

1

K

L9 - 58© P. Raatikainen Switching Technology / 2005

Channel grouping (cont.)

Maximum throughput per input

• increases with K/N for a given M (because load per output groupdecreases)

• increases with M for given K/N (because each output group hasmore ports for clearing cells)

M K/N = 1/16 1/8 1/4 1/2 1 2 4 8 16

1 0,061 0,117 0,219 0,382 0,586 0,764 0,877 0,938 0,969

2 0,121 0,233 0,426 0,686 0,885 0,966 0,991 0,998 0,999

4 0,241 0,457 0,768 0,959 0,996 1 1 1

8 0,476 0,831 0,991 1 1

16 0,878 0,999 1

Maximum throughput per input for some values of M and K/N

Page 235: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 235/369

L9 - 59© P. Raatikainen Switching Technology / 2005

Channel grouping (cont.)

• Maximum throughput per input increases with M for given KM/N

• Channel grouping has a strong effect on throughput for smallerKM/N than for larger ones

M KM/N = 1 2 4 8 16 32

1 0,586 0,764 0,877 0,938 0,969 0,984

2 0,686 0,885 0,966 0,991 0,998 0,999

4 0,768 0,959 0,966 1 1 1

8 0,831 0,991 1

16 0,878 0,99932 0,912 164 0,937

128 0,955

256 0.968

512 0,9781024 0,984

Maximum throughput as a function of line expansion ratio KM/N

L9 - 60© P. Raatikainen Switching Technology / 2005

Multicast output buffered ATM switch(MOBAS)

• Channel grouping extends to the general Knockout principle

• MOBAS adopts the general Knockout principle

• MOBAS consists of

• input port controllers (IPCs)

• multi-cast grouping networks (MGN1 and MGN2)

• multi-cast translation tables (MTTs)

• output port controllers (OPCs)

NxLNswitch

1

2

N

LMxMswitch

LMxMswitch

 . . .  . .

 .

LxM M

LxM M

1

KN-M+1

N

1

M

NxN switch withgroup extension ratio L

Page 236: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 236/369

L9 - 61© P. Raatikainen Switching Technology / 2005

MOBAS switch performance

• IPCs terminate incoming cells, look up necessary information intranslation tables and attach information in front of cells so that thecells can properly be routed in MGNs

• MGNs replicate multi-cast cells based on their multi-cast patterns andsend one copy to each addressed output group

• MTTs facilitate the multi-cast cell routing MGN2

• OPCs store temporarily multiple arriving cells (destined for their outputports) in an output buffer, generate multiple copies for multi-cast cells

with a cell duplicator (CD), assign a new VCI obtained from atranslation table to each copy, convert internal cell format to standardATM cell format and finally send the cell to the next switching node

• CD reduces output buffer size by storing only one copy of a multi-castcell - each copy is updated with a new VCI upon transmission

L9 - 62© P. Raatikainen Switching Technology / 2005

MOBAS architecture

IPC - Input Port Controller MGN - Multi-cast Grouping NetworkMTT - Multi-cast Translation Table

OPC - Output Port Controller SM - Switching ModuleSSM - Small Switch Module

1

N

IPC

 . . .

IPC

 . . .

SM 1

SM K

 . . .

MGN 1

 . . .

L1xM

 . . .

L1xM

Group 1

Group K

MTT

MTT

SM 1

SM M

 . . .  . .

 .

M

1

OPC

Outputbuffer 

L2

 . . . CD

Outputbuffer 

L2

 . . . CD

MGN2

MTT

MTT

SM 1

SM M

 . . .  . .

 .

N

N-M+1

OPC

Outputbuffer 

L2

 . . . CD

Outputbuffer 

L2

 . . . CD

MGN2

CD - Cell Duplicator  

Page 237: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 237/369

L9 - 63© P. Raatikainen Switching Technology / 2005

Abacus switch

• Knockout switches suffer from cell loss due to concentration/channelgrouping (i.e. lack of routing links inside switch fabric)

• In order to reduce CLR, excess cells are stored in input buffers=> result is an input-output buffered switch

• Abacus switch is an example of such a switch

• basic structure similar to MOBAS, but it does not discard cells inswitch fabric

• switching elements resolve contention for routing links based onpriority level of cells

• input ports store temporarily cells that have lost contention

• extra feedback lines and logic added to input ports

• distributed arbitration scheme allows switch to grow to a large size

L9 - 64© P. Raatikainen Switching Technology / 2005

Abacus switch (cont.)

IPC - Input Port Controller MGM - Multi-cast Grouping NetworkMTT - Multi-cast Translation Table

OPC - Output Port Controller RM - Routing ModuleSSM - Small Switch Module

1

N

IPC

 . . .

IPC

IPC

2

 . . .

RM 1

RM K

 . . .

MGM

SSM 1 . . .

LxM

M

MTT

MTT

OPC

OPC

 . . .

M

1

SSM K . . .

LxM

N

MTT

MTT

OPC

OPC

 . . .

M

N-M+1

 . . .

 . . .

Page 238: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 238/369

L9 - 65© P. Raatikainen Switching Technology / 2005

ATM switches

• General of ATM switching

• Structure of an ATM switch

• Example switch implementations

• Knockout switch

• Abacus

• Dimensioning example

L9 - 66© P. Raatikainen Switching Technology / 2005

Dimensioning example

• An ATM-switch is to be designed to support 20 STM-4 interfaces.RIT will be implemented at the input interfaces. How fast should RITlookup process be ?

• Cells are encapsulated into frames for delivery through the switch

fabric. A frame includes a 53-octet payload field and 3 octets ofoverhead for routing and control inside the switch fabric. What is therequired throughput of the switch fabric ?

Solution

• ATM cells are encapsulated into VC-4 containers, which include 9octets of overhead and 9x260 octets of payload. One VC-4container is carried in one STM-1 frame and each STM-1 framecontains 9x261 octets of payload and 9x9 octets of overhead. (Seefigure on the next slide)

Page 239: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 239/369

L9 - 67© P. Raatikainen Switching Technology / 2005

SOH

AU-4 PTR

SOH

9 octets261 octets

3

1

5

STM-1frame

ATM cell

J1

B3

C2

G1

F2

H4

Z3

Z4

Z5

...

...

... ...

...

...

VC-4frame

VC-4 POH

ATM cell encapsulation / SDH

L9 - 68© P. Raatikainen Switching Technology / 2005

Dimensioning example (cont.)

Solution (cont.)

• STM-4 frame carries 4 STM-1 frames and thus there will be4x9x260 / 53 = 176.6 cells arriving in one STM-4 frame

• One STM-4 frame is transported in 125 µs=> 176.6/125 µs = 1412830.2 cells will arrive to an input in 1 sec=> one RIT lookup should last no more than 707,8 ns

• Total throughput of the switch fabric is 20x1412830.2 cells/s

• Since each cell is carried through the switch fabric in a container of56 octets, the total load introduced by the inputs to the switch fabricis 20x1412830.2x56 octets/s ≈ 1.582 109 octets/s ≈ 12,7 Gbits/s

Page 240: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 240/369

L10 - 1© P. Raatikainen Switching Technology / 2005

Routers implementations

Switching Technology S38.165http://www.netlab.hut.fi/opetus/s38165

L10 - 2© P. Raatikainen Switching Technology / 2005

Router implementations

• General of routers

• Functions of an IP router • Router architectures

• Introduction to routing table lookup

Page 241: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 241/369

L10 - 3© P. Raatikainen Switching Technology / 2005

General of routers

• Router is a network equipment, which• performs packet switching operations

• operates at network layer of the OSI protocol reference model

• switches/routes variable length packets

• routing decisions based on address information carried in packets

• Router is used to connect two or more networks that mayor may not be similar

• Routers communicate with each other by means ofrouting messages to

• exchange routing information

• resolve next hop addresses

• maintain network topology to make routing decisions

L10 - 4© P. Raatikainen Switching Technology / 2005

IPv4 packet structure

Data field

Options + padding

Destination address (32 bits)

Source address (32 bits)

Time to live Protocol

Identifier

Ver. IHL TOS

4 4 168 3

Header checksum

Flag Fragment offset

Length

   2   0  o  c   t  e   t  s

Flag - used in connection with fragmentation: more bit indicates whether this fragment is the last one of afragmented packet and don’t fragment bit inhibits/prohibits packet fragmentationFragment offset - indicates where in the original user data message this fragment belongs, measured in 64-bit units(all but last the fragment has a data field that contains a multiple of 64-bit payload)Time-to-live - defines the maximum time in seconds a packet can be in transit across the Internet (decremented byeach visited router by a defined amount)Protocol - indicates the type of protocol (TCP, UDP, etc.) carried by the IP packetHeader checksum - carries a checksum calculated over the header bits

Version - IP version numberIHL - Internet header length in 32-bit words (min. size = 5)TOS - type of service (guidance toend-system IP modules and routeralong transport path)

Length - total length (header +payload) of IP packet in octetsIdentifier  - sequence number,which together with address andprotocol fields identify each IPpacket uniquely

Page 242: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 242/369

L10 - 5© P. Raatikainen Switching Technology / 2005

IPv6 packet structure

Data field

Destination address (128 bits)

Source address (128 bits)

Payload length (16)

Version Traffic class

4 8 20

Next header (8)

   4   0  o  c   t  e   t  s

Hop limit (8)

Flow label

Payload length - indicates the number of octets in the payload fieldNext header - indicates the type of additional (extension) header following the main headerHop limit - value for the maximum number of hops the packet is allowed to travel in a network

Version - version number of IPprotocolTraffic class - Class-of-service(CoS) priority of the packetFlow label - identifies all packetsbelonging to a specific flow(requiring a specific CoS), androuters can identify these packetsand handle them in a similarfashion. A flow is uniquely

identified by the combination of asource address and a non-zeroflow label.

L10 - 6© P. Raatikainen Switching Technology / 2005

Router implementations

• General of routing

• Functions of an IP router • Router architectures

• Introduction to routing table lookup

Page 243: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 243/369

L10 - 7© P. Raatikainen Switching Technology / 2005

Major tasks of a router 

C - Classify (classification, filtering and routing)F - Forward (transfer of packets from input interfaces to addressed

output interfaces)S - Scheduling (transmission of data packets based, e.g. on priority)

In_port

 . . .C

 . . .

F

F

F

SOut_port

L10 - 8© P. Raatikainen Switching Technology / 2005

Main functional blocks of a router 

Networkprocessor 

InputInterfaceCard #1

InputInterfaceCard #1Input port #1

Switchfabric

InputInterfaceCard #1

InputInterfaceCard #1Output port #1

Generic router architecture

Page 244: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 244/369

Page 245: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 245/369

L10 - 11© P. Raatikainen Switching Technology / 2005

Switch fabric functionality

• Main function is to route data packets from input ports to addressedoutput ports

• Depending on the switch fabric implementation, packets aretransported through the fabric either as uniform variable lengthpackets or they are fragmented to fixed size data units

• In either case, extra information is added in front of the packets todirect them through the fabric

• switching of whole packets is usually applied in low-speed routers

• switching of fragments is normally used in high-speed routers

• Majority of switch fabrics are based on three basic architectures: busbased, memory based and interconnection network based

L10 - 12© P. Raatikainen Switching Technology / 2005

Network processor functionality

• Maintenance of routing table

• Execution of routing protocols

• Maintenance of routing topology

• Performance of network management

• Wire-speed operation obtained byimplementing key functions inhardware

• Processing of packets- classification- order management- acceleration of lookup- queue management- QoS engine

Network processor functionality

Classifier Classifier Classifier 

Order management

Embeddedprocessor 

Embeddedprocessor 

Embeddedprocessor 

Lookup Lookup Lookup

Queue management

QoS QoS QoS

Incoming packets

Outgoing packets

Page 246: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 246/369

L10 - 13© P. Raatikainen Switching Technology / 2005

Router classification• Access routers

• link homes and small business to ISPs (Internet Service Provider)

• need to support a variety of access technologies, e.g. high-speedmodems, cable modems and xDSL

• Enterprise/metropolitan routers

• used as campus and office interconnects

• QoS guarantees for local traffic

• support of several network layer protocols (e.g. IP and IPX)

• support of additional features, such as firewalls, security policies and

virtual LANs

• Backbone/long haul routers

• interconnect enterprise routers

• huge number of packets per second => very-high-speed requirement

• critical components for interworking => reliability of utmost concern

L10 - 14© P. Raatikainen Switching Technology / 2005

Router implementations

• General of routing

• Functions of an IP router• Router architectures

• Introduction to routing table lookup

Page 247: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 247/369

L10 - 15© P. Raatikainen Switching Technology / 2005

Basic types of router architecture

 …

ForwardingEngine

ForwardingEngine

ForwardingEngine

 …

LineInterface

LineInterface

LineInterface

Networkprocessor 

Router with forwarding engines

 …

Line Int. +Forwarding

Line Int. +Forwarding

Line Int. +Forwarding

Networkprocessor 

 …

Line Int. +Forwarding

Line Int. +Forwarding

Line Int. +Forwarding

Router with added processingpower in interfaces

L10 - 16© P. Raatikainen Switching Technology / 2005

First generation router architecture

• Network layer protocols were constantly changing=> adaptable solution was needed=> a single and common purpose processor structure was areasonable one in which operating system in central role

• Low throughput (packets transferred twice through the bus)

did not scale well with increasing line speeds

CPU

Interfacecard #1Interfacecard #1Interfacecard #1

Shared bus, a single processor card and line interface cards

Page 248: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 248/369

Page 249: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 249/369

L10 - 19© P. Raatikainen Switching Technology / 2005

Support of differentiated services

• Packet classification - distinguish packets and group themaccording to their different requirements

• Buffer management - determine how much buffer space should begiven to certain kinds of network traffic and which packets shouldbe discarded in case of congestion

• Packet scheduling - decide that the packet servicing order meetsthe bandwidth and delay requirements of different types of traffic

Traditional routers are limited in terms of their quality of service anddifferentiation features. Advances in research and hardware capabilitieshave provided mechanisms to overcome these limitations. Followingoperations, possible today to carry out in high speed, allow provisioningof differentiated services:

L10 - 20© P. Raatikainen Switching Technology / 2005

DiffServ routing

Router 1 Router 2

Host 1 Host 2

Phys. (twisted pair) Phys. (optical) Phys. (twisted pair)

100 MbE

Eth. MAC

IP

TCP/UDP

Appl.

100 MbE

Eth. MAC

1 GbE

Eth. MAC

IP

1 GbE

Eth. MAC

100 MbE

Eth. MAC

IP

100 MbE

Eth. MAC

IP

TCP/UDP

Appl.

TCP/UDP TCP/UDP

Page 250: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 250/369

L10 - 21© P. Raatikainen Switching Technology / 2005

DiffServ routing (cont.)

Router 1 Router 2

Host 1 Host 2

Phys. (twisted pair) Phys. (optical) Phys. (twisted pair)

100 MbE

Eth. MAC

IP

TCP/UDP

Appl.

100 MbE

Eth. MAC

1 GbE

Eth. MAC

IP

1 GbE

Eth. MAC

100 MbE

Eth. MAC

IP

100 MbE

Eth. MAC

IP

TCP/UDP

Appl.

TCP/UDP TCP/UDP

Appl. Appl.

L10 - 22© P. Raatikainen Switching Technology / 2005

Sharing of processing resources andpipelining

DiffServ-optimized router architecture

Interface card #1+ multiple special

purpose CPUs

Interface card #1+ multiple special

purpose CPUs

Interface card #1+ multiple special

purpose CPUs

Interface card #1

+ multiple specialpurpose CPUs

Concentrator 

Filtering

Scheduler 

RouteLookup

Buffering

Page 251: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 251/369

L10 - 23© P. Raatikainen Switching Technology / 2005

Sharing of processing resources and

pipelining (cont.)

• Packet processing divided into a number of consecutive processes -each process has a dedicated processing unit (buffering, filtering,routing, etc.)

• Pipelined processes shared by several interfaces to increase numberof line interfaces - concentrator schedules packets for processes

• QoS-based scheduler takes care of packet transmission from buffers

to outbound interfaces

L10 - 24© P. Raatikainen Switching Technology / 2005

Packet processing capacity

• Packet processing capacity of a router is given as the number offorwarded packets/second and/or forwarded bits/second

• Tasks affecting forwarding speed- link protocol processing delay (input and output)

- address lookup time- switching of packets from input ports to outputs ports- queuing at output ports and possibly at input ports

• Other tasks that may have an impact on forwarding speed- routing table management/updates- network and router management

• In high capacity routers, routing table lookups are a major problem

• Queuing is the main component of routing latency

• Routing capacity requirement determined by the shortest packets

Page 252: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 252/369

L10 - 25© P. Raatikainen Switching Technology / 2005

Future challenges

• Increase of line speeds- 100 Mbit/s => 1 Gbit/s => 10 Gbit/S => 40/100 Gbit/s

• QoS-support => increased processing need- DiffServ, IntServ, MPLS, ...

• From “best effort” service to controlled use of networkresources=> programmable network nodes

• Different needs in the core and edge networks- huge routing capacity in the core network ( > 10 million packets/s)- a lot of functionality and intelligence in the edge routers

L10 - 26© P. Raatikainen Switching Technology / 2005

Speedup mechanisms for routing tablelookup

• Caching

 – routing table entries of most lately arrived packets or entriesmost frequently accessed are stored in cache memory

• Pipelining

 – different phases of routing table lookup are executed bydifferent pipelined processing units

• Distribution of lookup to interfaces or to several routing engines

 – network processor takes care of routing table updates anddistributes updated tables to separate interface/routing engines

• In centralized routing solutions only packet headers are sent to arouting processor

• Implementation of lookup functionality in hardware (at the expenseof flexibility)

Page 253: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 253/369

L10 - 27© P. Raatikainen Switching Technology / 2005

Caching to speedup packet processing

and forwarding

• When a packet with a new destination address arrives to an inputport, it passes through the conventional routing process (slow path)and its routing entry is stored in cache memory

• Subsequent packets carrying the same destination address arerouted using the routing entry in the cache memory (fast path)

• A routing entry is removedfrom cache when predefinedconditions to keep it in cache

expire, e.g. packet arrivalrate declines or time sincethe last packet becomestoo long

 …

 …

 …

Fast path

Slow path

Fast path

Slow path

 …

1

N

1

N

L10 - 28© P. Raatikainen Switching Technology / 2005

High speed router examples

• GSR /Cisco- first gigabit router on the market- switching capacity of 27.5 Gbits/s- equipped with POS (Packet Over Sonet) and ATM interfaces

• 12000 Terabit System /Cisco

- initial switching capacity of 150 Gbits/s, but scalable up to 5 Tbits/s

- can be equipped with OC192/STM-64 (10 Gbits/s) interfaces

• NX64000 /Lucent (Nexabit)- one of the highest capacity routers (6.4 Tbits/s)- supports interface rates up to OC192/STM-64- distributed programmable hardware based forwarding engine- 1 million routing entries on each line card- 40 ms delay guarantee for variable size packets

Page 254: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 254/369

L10 - 29© P. Raatikainen Switching Technology / 2005

High speed router examples (cont.)

• MGR (Multi-Gigabit Router) /BBN Technologies- forwarding rate up to 21 million packets per second- switching backplane capacity of 50 Gbits/s- multiple line cards and separate forwarding engine cards pluggedinto a high-speed switch- only packet headers are directed to forwarding engines- payloads queued on line cards

• TSR (Terabit Switch-Router) / Avici

- designed to be scalable from 600 Mbit/s to several Tbits/s- hardware based routing, forwarding, multi-casting and QoS service- each line card implements a 70 Gbit/s router and 20 such line cardsfit into a dual-shelf chassis=> total switching capacity is 1.4 Tbits/s

L10 - 30© P. Raatikainen Switching Technology / 2005

Example of routing table lookup speeddetermination

In a distributed routing table lookup solution, each input portimplements a routing table. What is the maximum allowed routingdecision delay if the input link is a 100 Mbit/s Ethernet link or 1 Gbit/slink and the router should operate at wire-speed ?

Solution:

• In both example cases, the routing decision delay requirementcorresponds to maximum packet arrival rate at these interfaces

• The maximum packet arrival rate is encountered when there is aconstant stream of minimum size Ethernet frames

• The minimum size 100 MbE frame is 64 octets and there are 8octets of preamble and SFD information in front of each frame and

additionally there is always a 0.96 µs time gap between successiveframes

Page 255: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 255/369

L10 - 31© P. Raatikainen Switching Technology / 2005

Example of routing table lookup

determination (cont.)Solution (cont.):

• Time required to transmit 72 octets (64+8) at the speed of 100Mbit/s is 5.76 µs => minimum time interval between successiveframes is 5.76 µs + 0.96 µs = 6,72 µs, which is also the maximumallowed routing decision delay for a 100 MbE input port=> forwarding capacity is about 149 000 packets/s

• The minimum size 1 GbE frame is 512 octets and there are 8 octetsof preamble and SFD information in front of each frame and there is

a 96 ns time gap between successive frames• Time required to transmit 520 octets (512+8) at the speed of 1 Gbit/s

is 4.16 µs => minimum time interval between successive frames is4.16 + 0.096 µs = 4.256 µs, which is also the maximum allowedrouting decision delay for a 1 GbE input port (frame bursting excluded)=> forwarding capacity is about 235 000 packets/s

L10 - 32© P. Raatikainen Switching Technology / 2005

10/100 MbE frame

Preamble

S

FD DA SA T/L Payload CRC

7 1 6 6 2 46 - 1500 4

64 - 1518 octets

Preamble - AA AA AA AA AA AA AA (Hex)SFD - Start of Frame Delimiter AB (Hex)DA - Destination AddressSA - Source AddressT/L - Type (RFC894, Ethernet) or Length (RFC1042, IEEE 802.3) indicator CRC - Cyclic Redundancy CheckInter-frame gap 12 octets (9,6 µµµµs /10 MbE)

Page 256: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 256/369

L10 - 33© P. Raatikainen Switching Technology / 2005

1GbE frame

PreambleSFD

DA SA L Payload

7 1 6 6 2 46 - 1500 4

512 - 1518 octets

CRC Extension

Preamble- AA AA AA AA AA AA AA (Hex)

SFD- Start of Frame Delimiter AB (Hex)DA- Destination AddressSA- Source AddressT/L- Type (RFC894, Ethernet) or Length (RFC1042, IEEE 802.3) indicator CRC- Cyclic Redundancy CheckInter - frame gap 12 octets (96 ns /1 GbE)Extension- for padding short frames to be 512 octets long

L10 - 34© P. Raatikainen Switching Technology / 2005

Router implementations

• General of routing

• Functions of an IP router• Router architectures

• Introduction to routing table lookup

Page 257: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 257/369

L10 - 35© P. Raatikainen Switching Technology / 2005

Classful addressing scheme

• In IPv4, addresses are 32 bits long - broken up into 4 groups of 8 bitsand represented usually as four decimal numbers separated by dots,e.g., 10000010 01010110 00010000 01000010 = 130.86.16.66

• IP intended for interconnecting networks => routing based onnetwork is a natural choice (rather than based on host)

• IP address scheme initially used a simple two level hierarchy -networks at the top level and hosts at the bottom level

• Network part (i.e. address prefix) corresponds to the fist bits

• Prefixes written as bit strings up to 32 bits in IPv4 followed by “*”- e.g. 1000001001010110* represents all the 216 addresses that begin withbit pattern 1000001001010110- an alternative way is to use dotted-decimal expression, i.e., 130.86/16(number after the slash indicates length of prefix)

L10 - 36© P. Raatikainen Switching Technology / 2005

Classful addressing scheme

• With the two level hierarchy, IP routers forwarded packets based onthe network part, until packets reached their destination network

• Forwarding table only needed to store a single entry to forwardpackets to all hosts attached to the same network - technique is

called address aggregation and allows prefixes to represent a groupof addresses

• Three different network sizes were defined: A, B and C (see figure)

0

10

110

7 24

14 16

21 8

Class A

Class B

Class C

Page 258: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 258/369

L10 - 37© P. Raatikainen Switching Technology / 2005

Classful addresses

• Classful addressing scheme worked well in the early days of theInternet

• Two basic problems appeared when the number of hosts andnetworks grew

• address space was not efficiently used (only three possiblenetwork sizes available) and was getting exhausted very rapidly

• forwarding tables in the backbone routers grew rapidly, becauserouters maintain an entry in the forwarding table for everyallocated network address=> larger memory requirement => long lookup times

L10 - 38© P. Raatikainen Switching Technology / 2005

Classless InterDomain Routing (CIDR)

• CIDR was introduced to allow more efficient use of IP address spaceand to slow down growth of backbone routing tables

• CIDR allows prefixes to be of arbitrary length, not just 8, 16 or 24 bitsas in classful address scheme

• A network that has identical routing information for all sub-nets, exceptfor a single one, requires only two entries in the routing table

• In CIDR, each IP route is represented by aroute_prefix / prefix_length pair

 – prefix length indicates the number of significant bits in a route prefix

 – e.g. a routing table may have prefixes 12.0.54.8/32, 12.0.54.0/24and 12.0.0.0/16. If a packet is destined for address 12.0.54.2, thesecond prefix matches

Page 259: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 259/369

L10 - 39© P. Raatikainen Switching Technology / 2005

Difficulties with longest match prefix

search• In classful addressing scheme, prefix length is coded in the most

significant bits of an IP address=> address lookup is a relatively simple operation

- prefixes are organized in three separate tables (A, B and C)=> an exact prefix match could be found using standard searchalgorithms based on hashing or binary search

• CIDR allows reduced size of forwarding tables, but address lookupproblem becomes more complex=> prefixes are of arbitrary length and no longer correspond to thenetwork part=> search in the forwarding table can no longer be performed byexact matching, because the length of the prefix cannot be derivedfrom the address itself=> searching in two dimensions: bit pattern value and length

L10 - 40© P. Raatikainen Switching Technology / 2005

Route lookup

• Primary goal in designing a data structure to be used in a forwarding

table is to minimize lookup time, i.e.

- minimize number of memory accesses required during lookups

- minimize size of data structure (to fit partly or entirely into a cache)

• Secondary goals of a data structure

- as few instructions during lookup as possible

- keep the entities naturally aligned as much as possible to avoid

expensive instructions and cumbersome bit-extraction operations

• A binary tree, spanning the entire IPv4 address

space has a height of 32 and number

of leaves is 232

232 leaves (IP addresses)

   D  e  p   t   h   3   2

Page 260: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 260/369

L10 - 41© P. Raatikainen Switching Technology / 2005

Route lookup (cont.)

• A prefix of a routing table entry defines a path in the tree ending in

some point and all IP addresses (leaves) in a sub-tree, rooted at that

node, should be routed according to that routing entry, i.e. each

routing table entry defines a range of IP addresses with identical

routing information

• If several routing entries cover an IP address, the longest matching

rule is applied, i.e. the longest applicable prefix should be used

• In the figure below, e2 represents a longermatch than e1 for addresses

in range r e1

e2

L10 - 42© P. Raatikainen Switching Technology / 2005

Route lookup based on binary trie

• A trie is a tree-based structure allowing to organize prefixes on a

digital basis by using the bits of prefixes to direct the branching

• In a trie, a node on level k represents the set of all addresses that

begin with the same k bits that label the path from the root to thatnode, e.g. node c in the figure on the next slide is at level 3 and

represents all addresses beginning with the sequence 011

• Nodes that correspond to prefixes are shown in a darker shade -

these nodes contain the forwarding information or a pointer to it

• Some addresses may match several prefixes, e.g. addresses

beginning with 011 will match prefixes c and a => prefix c is

preferred because it is more specific (longest match rule)

Page 261: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 261/369

Page 262: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 262/369

L10 - 45© P. Raatikainen Switching Technology / 2005

Route lookup based on binary trie• Tries allow finding the longest prefix that matches a given destination

address and the search is guided by the bits of the destination address

• While traversing the trie and visiting a node marked as a prefix, thisprefix is marked as the longest match found so far

• The search ends when no more branches to take exist and the longestmatch is the prefix of the latest visited prefix node

• An example address 10110

 – from root move to the right (1st bit value = 1) to node d marked as a prefix,

i.e. 1st found prefix is 1* – then move to the left (2nd bit value = 0) to a node not marked as a prefix

=> prefix d still valid

 – 3rd address bit = 1, but at this point there is no branch to the right=> search stops=> d is the last visited prefix node and prefix of d is the longest match

L10 - 46© P. Raatikainen Switching Technology / 2005

Route lookup based on binary trie (cont.)

• Going trough a trie is a sequential prefix search by length when trying

to find a better match

 – begin looking in the set of length-1 prefixes, located at level 1

 – then proceed in the set of length-2 prefixes at level 2,

 – then proceed to level 3 and so on• While stepping through a trie, the search space reduces hierarchically

 – at each step, the set of potential prefixes reduces and the search ends

when this set is reduces to one

• Update operations are straightforward

 – inserting a new prefix proceeds as a normal search and when arriving toa node with no branch to take, insert the necessary node

 – deleting a prefix proceeds also as a search and when finding therequired node, unmark it as a prefix node and delete it if necessary

Page 263: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 263/369

L10 - 47© P. Raatikainen Switching Technology / 2005

Path-compressed tries

• In binary tries, long sequences of one-child nodes may exist and

these bits need to be inspected even though the actual branching

decision has been made

=> search time can be longer than necessary

=> one-child nodes consume additional memory

• Lookup time of a binary trie is O(W) and memory requirement O(NW)

 – W is the address length in bits and N the number of entries in a table

• Path-compression technique can be used to remove unnecessary

one-way branch nodes and reduce search time and memory

consumption

L10 - 48© P. Raatikainen Switching Technology / 2005

Path-compressed tries (cont.)

• Path-compression was first introduced in a scheme called Patricia,which is an improvement of the binary trie structure

• it is based on the observation that an internal node, which does notcontain a prefix and has only one child, can be removed

• removal of internal nodes requires information of missing nodes to beadded in remaining nodes so that search operations can be performedcorrectly, e.g. a simple mechanism is to store a number, which indicateshow many nodes have been skipped (skip value) or the number of thenext address bit to be inspected

• There are many ways to exploit path-compression technique, anexample is shown on the next slide

• Lookup time is O(W) and worst case storage requirement O(NW)

Page 264: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 264/369

Page 265: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 265/369

L10 - 51© P. Raatikainen Switching Technology / 2005

Search in a path-compressed trie

Search goes as follows:

• Start from the root and descent in the trie under the guidance of theaddress bits, but this time only inspect bit positions indicated by thebit position number in the nodes traversed

• When a node marked as a prefix is encountered, comparison withthe actual prefix is performed - this is needed, because during thedescent in the trie, we may skip some bits

• If a match is found, we proceed traversing the trie and keep the prefixas the best match prefix (BMP) so far

• Search ends when a leaf is encountered or a mismatch found

• BMP is the last matching prefix encountered

L10 - 52© P. Raatikainen Switching Technology / 2005

A path-compressed trie example (cont.)

In the previous example case, take an address beginning with 010110

• start from root and since its bit position number is 1, inspect the firstbit of the address

=> 1st bit is 0 => go to the left=> since this node is marked as a prefix, compare prefix a (“0”) withthe corresponding part of the address => they match=> keep a as the BMP so far=> bit position number of the new node is 3 so skip the 2nd addressbit and inspect the 3rd one, which is 0 => proceed left=> next node includes a prefix so compare prefix b with thecorresponding part of address=> no match => stop search => the last recorded BMP is a

Page 266: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 266/369

L10 - 53© P. Raatikainen Switching Technology / 2005

Multibit trie

• Drawback of binary (1-bit) trie is that one bit at a time is inspectedand the number of memory accesses (in the worst case) can be 32for IPv4

• Number of lookups can be substantially decreased by using themultibit trie structure, i.e. several bits are inspected at a time

• for example, inspecting four bits at a time would lead to only 8 memoryaccesses in the worst case for an IPv4 address

• Number of bits (K) to be inspected is called a stride and the stride

can be constant or variable• In a K-bit trie, each node has 2K pointers (children)

• If a route prefix is not a multiple of K, it needs to be expanded to Kor its multiples

• Lookup time is O(W/K) and storage requirement O(2 (K-1) NW/K)

L10 - 54© P. Raatikainen Switching Technology / 2005

Multibit trie example 1

• Prefixes a and d are expanded to length 2 and prefix c has beenexpanded to length 4 (rest of the prefixes remain unchanged)

• Height of the trie has been decreased and so has the number ofmemory accesses when doing a search

0 1

a

b

c

0

0

0

1

d

e

0

0

0

11

f g h i

0

0

1

11

Uncompressed binary trie

0 1

b

00cc

01 10 11e0 1

f g h i00 01 10 11

d

00 11

a a

01 10

d

Variable stride multibit trie

Information stored by a node:

Next-hop pointer (if prefix)

Ptr00 Ptr01 Ptr10 Ptr11

Page 267: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 267/369

L10 - 55© P. Raatikainen Switching Technology / 2005

Multibit trie example 2

• An alternative multibit trie of the previous example case- prefixes a and d have been expanded to length 3- rest of the prefixes remain the same as before expansion

• When an expanded prefix collides with an existing one, forwardinginformation of the existing one must be maintained (to respect thelongest match)

h h i i

00 01 10 11

b

00 01 10 11 00 01 10 11

f f g g

e

000 011

a c

001 010

d da da

100 111101 110

Fixed stride multibit trie

L10 - 56© P. Raatikainen Switching Technology / 2005

Search in a multibit trie

• Search in a multibit trie is essentially the same as search in a binary(1-bit) trie - successively look for longer prefixes that match and thelast one found is the longest match prefix for a given address

• Multibit tries do linear search on length as do the binary tries, but thesearch is faster because the trie is traversed using larger strides

• A multibit trie is a fixed stride system, if all nodes at the same levelhave the same stride size, otherwise it a variable stride system

• Fixed strides are simpler to implement than variable strides, butusually consume more memory

Page 268: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 268/369

Page 269: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 269/369

L10 - 59© P. Raatikainen Switching Technology / 2005

LC-trie exampleUncompressedbinary trie 0 1

a

b

c

0

0

0

1

d

e

0

0

0

11

f g h i

0

0

1

11Compressedbinary trie

01

a

b c

0 1

3d

f g h i

e

1

0

0

0 0

1

1

1

2

3

14 4

b c

f g h i

eb c

f g h i

e

LC-trie

Prefixes:a - 0*b - 01000*c - 011*d - 1*e - 100*

f - 1100*g - 1101*h - 1110*I - 1111*

L10 - 60© P. Raatikainen Switching Technology / 2005

Level compression trie (cont.)

• To save memory, all nodes in LC-trie are stored in a single node array

• first root, then all nodes at the second level, then all nodes at third level,and so on

• all the descendants of an internal nodes are stored in consecutive memorylocations => an internal node only needs to point to its first descendant

b001 /b

1020 /root

i008 /i

h007 /h

g006 /g

f 005 /f 

5324

e003 /e

c002 /c

Pointer SkipBranchIndex• Information stored in each node

•  branch  – number of descendants of a node(always power of 2)

•  skip number  – number of bits to be skippedat this node during search operation

•  pointer  – an internal node points to its firstdescendant (given as the index value of thefirst child node) and leaf node points to oneentry of another base vector table, where thereal prefix and next-hop information are stored

Page 270: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 270/369

L10 - 61© P. Raatikainen Switching Technology / 2005

Level compression trie (cont.)

• Each entry of the base vector table includes

• complete string of the prefix

• next-hop information

• special prefix vector, which

• contains information of strings thatare proper prefixes of other strings

• is needed because internal nodesof an LC-trie do not contain pointers

to the base vector table• this information implies whether there

exists a longer prefix matching the IPaddress and gives the next-hop information in case of a match

• Lookup time is O(W/K) and memory requirement is O(2K NW/K)

d=1/ptr_dptr_i1111id=1/ptr_dptr_h1110h

Special prefixvector 

Nexthop

Prefix bitstring

Index

a=0/ptr_aptr_b01000b

d=1/ptr_dptr_g1101g

d=1/ptr_dptr_f 1100f 

d=1/ptr_dptr_e100e

a=0/ptr_aptr_c011c

L10 - 62© P. Raatikainen Switching Technology / 2005

Multibit tries in hardware

• In core network routers, lookup times are very short and lookupalgorithms are implemented in hardware to obtain required speed

• Basic scheme uses two level multibit trie with fixed strides- 24 bits at the first level and 8 at the second level

• In backbone routers, most of the entries have a prefix length of 24 bitsor less => longest match prefix found in one memory access in themajority of cases

• Only a small number of sub-entries at the 2nd level

• To save memory, internal nodes not allowed to store prefixes=> prefixes corresponding to internal nodes expanded to 2nd level=> result is a multibit trie with disjoint expanded prefixes - 1st levelhas 224 nodes and is implemented as a table with the same number ofentries

Page 271: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 271/369

L10 - 63© P. Raatikainen Switching Technology / 2005

Multibit tries in hardware (cont.)

• An entry at the 1st level contains either the forwarding information ora pointer to the corresponding sub-trie at the 2nd level - two bytesneeded to store a pointer/forwarding information=> a memory bank of 32 Mbytes is needed to store 224 entries

1st memorybank

0

23

31

0

1

Destinationaddress

2nd memorybank

24

8220 entries

224 entries

Forwarding

information

L10 - 64© P. Raatikainen Switching Technology / 2005

Multibit tries in hardware (cont.)

• Number of sub-tries at the 2nd level depends on the number ofprefixes longer than 24 bits

• 2nd level stride is 8 bits => a sub-trie at the 2nd level has 28=256leaves

• Size of 2nd memory bank depends on the expected worst case prefixlength distribution, e.g. 220 one byte entries (a memory bank of 1Mbytes) supports a maximum of 212= 4096 sub-tries at the 2nd level

• Lookup requires a maximum of two memory accesses- memory accesses can be pipelined or parallelized to speed upperformance

• Since the first stride is 24 bits and leaf pushing is used, updates maytake a long time in some cases

Page 272: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 272/369

L10 - 65© P. Raatikainen Switching Technology / 2005

New directions in IP lookup

• More efficient lookup schemes have been developed to improve theaverage lookup performance and storage complexity

• Examples of new methods are

• Binary search on trie levels, which decomposes the longest prefixoperation into W exact matching operations, each performed on prefixesof equal length

• Multiway or K-way range search, which applies a binary search to bestmatching prefixes by using two routing entries per prefix and with some

precomputation• Ternary CAM uses a special CAM (Content Addressable Memory),

which performs parallel comparisons internally. TCAM stores each W-bitfield as a [val, mask] pair and when a bit string is presented to the input,

TCAM outputs the location (or address) where a match is found.

L10 - 66© P. Raatikainen Switching Technology / 2005

New directions in IP lookup (cont.)

• Conventional routers offer the best-effort service by processing eachincoming packet in the same way. New applications require differentQoS levels and to meet these requirements new mechanisms, suchas admission control, resource reservation and per-flow queuing,

need to be implemented in routers.

• Routers are required to distinguish and classify incoming traffic intodifferent flows

• Flows are specified by rules and each rule consists of operations forcomparing packet fields with certain values

• Packet fields to be inspected are collected from different protocols=> packet classification

Page 273: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 273/369

L10 - 67© P. Raatikainen Switching Technology / 2005

Comparison of some lookup schemes

Source: Proceedings of the IEEE, vol. 90, No. 9, 2002

W - length of address in bits, N - number of prefixes in a prefix set,K - stride size

-O(N)O(1)TCAM

O(N)O(N)O(log2W)K-way rang search

O(log2W)O(Nlog2W)O(log2W)Binary search on tries level

-O(2KNW/K)O(W/K)LC-trie

O(W/K+2K)O(2KNW/K)O(W/K)K-stride multibit trie

O(W)O(N)O(W)Path compressed trie

O(W)O(NW)O(W)Binary trie

UpdateMemoryWorst case

lookupScheme

L10 - 68© P. Raatikainen Switching Technology / 2005

Lookup scalability and IPv6

• On scalability point of view, important aspects are the number ofentries in a lookup table and the prefix length

• Multibit tries improve lookup speed with respect to binary tries, but

only by a constant factor on the length dimension=> multibit tries scale badly to longer addresses (128 bit in IPv6)

• Binary search on tries level has logarithmic complexity with respect toprefix length => scalability very good for IPv6

• Range search has logarithmic lookup complexity with respect to thenumber of entries, but independent of prefix length=> if the number of entries does not grow excessively, range searchis scalable for IPv6

Page 274: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 274/3691

11 - 1P. Raatikainen Switching Technology / 2003

Introduction to MultiwavelengthOptical Networks

Switching Technology S38.165

http://www.netlab.hut.fi/opetus/s38165

Source: Stern-Bala (1999), Multiwavelength Optical Networks

11 - 2P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

• Network Connections

Page 275: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 275/3692 

11 - 3P. Raatikainen Switching Technology / 2003

Optical network

• Why optical networks?

– “The information superhighway is still a dirt road; more accurately, it is aset of isolated multilane highways with cow paths for entrance.”

• Definition: An optical network is a telecommunications network

– with transmission links that are optical fibers, and

– with an architecture designed to exploit the unique features of fibers

• Thus, the term optical network (as used here)

– does not necessarily imply a purely optical network,

– but it does imply something more than a set of fibers terminated by

electronic switches

• The “glue” that holds the purely optical network together consists of

– optical network nodes (ONN) connecting the fibers within the network

– network access stations (NAS) interfacing user terminals and othernonoptical end-systems to the network

11 - 4P. Raatikainen Switching Technology / 2003

Network categories

Multiwavelength optical network= WDM network= optical network utilizing wavelength division multiplexing (WDM)

– Transparent optical network = purely optical network

• Static network = broadcast-and-select network

• Wavelength Routed Network (WRN)

• Linear Lightwave Network (LLN) = waveband routed network

– Hybrid optical network = layered optical network

• Logically Routed Network (LRN)

Page 276: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 276/3693 

11 - 5P. Raatikainen Switching Technology / 2003

Physical picture of the network

NAS

NAS

NAS

NAS

NAS

NAS

Work-station

Multimediaterminal

Super-computer 

Multimediaterminal

LAN

ONN

LANLAN

ATM

ATM

ATM

ATM

ONN - Optical Network NodeNAS - Network Access StationLAN - Local Area Network

11 - 6P. Raatikainen Switching Technology / 2003

Wide area optical networks - a wish list

•Connectivity

– support of a very large number of stationsand end systems

– support of a very large number ofconcurrent connections including multiple

connections per station– efficient support of multi-cast connections

•Performance

– high aggregate network throughput(hundreds of Tbps)

– high user bit rates (few Gbps)

– small end-to-end delay

– low error rate / high SNR

– low processing load in nodes and stations

– adaptability to changing and unbalancedloads

– efficient and rapid means of faultidentification and recovery

•Structural features

– scalability

– modularity

– survivability (fault tolerance)

•Technology/cost issues

– access stations: small number ofoptical transceivers per station andlimited complexity of opticaltransceivers

– network: limited complexity of theoptical network nodes, limitednumber and length of cables andfibers, and efficient use (and reuse)of optical spectrum

Page 277: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 277/3694 

11 - 7P. Raatikainen Switching Technology / 2003

Optics vs. electronics

Optical domain

•photonic technology is well suited to

certain simple (linear) signal-routing and

switching functions

•optical power combining, dividing and

filtering

•wavelength multiplexing,

demultiplexing and routing

•channelizing needed to make efficient

use of enormous bandwidth of the fiber

•by wavelength division multiplexing

(WDM)•many signals operating on different

wavelengths share each fiber

=> optics is fast but dumb

  - connectivity bottleneck

Electrical domain

• electronics is needed to perform more

complex (nonlinear) functions

•signal detection, regeneration and

buffering

•logic functions (e.g. reading and

writing packet headers)

• however, these complex functions limit

the throughput

• electronics also gives a possibility to

include in-band control information (e.g.

in packet headers)•enabling a high degree of virtual

connectivity

• easier to control

=> electronics is slow but smart

  - electronic bottleneck

11 - 8P. Raatikainen Switching Technology / 2003

Optics and electronics

Hybrid approach:

– a multiwavelength purely optical network as a physical foundation

– one or more logical networks (LN) superimposed on the physical layer, each

• designed to serve some subset of user requirements and

• implemented as an electronic overlay

– electronic switching equipment in the logical layer acts as a middleman

• taking the high-bandwidth transparent channels provided by the physical layer

and organizing them into an acceptable and cost-effective form

Why this hybrid approach ?

– purely optical wavelength selective switches:

• huge aggregate throughput of few connections

– electronic packet switches:

• large number of relatively low bit rate virtual connections

– hybrid approach exploits the unique capabilities of optical and electronic switching

while circumventing their limitations

Page 278: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 278/3695 

11 - 9P. Raatikainen Switching Technology / 2003

Example LAN interconnection

• Consider a future WAN serving as a backbone that interconnects a largenumber of high-speed LANs (say 10,000), accessing the WAN throughLAN gateways (with aggregate traffic of tens of Tbps)

• Purely optical approach

– each NAS connects its LAN to the other LAN’s through individual

optical connections⇒ 9,999 connections per NAS

– this is far too much for current optical technology

• Purely electronic approach

– electronics easily supports required connectivity via virtual connections

– however, the electronic processing bottleneck in the core network doesnot allow such traffic

• Hybrid approach: both objectives achieved, since

– LN composed of ATM switches provides the necessary connectivity

– optical backbone at the physical layer supports the required throughput

11 - 10P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

– Network Links: Spectrum Partitioning– Layers and Sublayers

– Optical Network Nodes

– Network Access Stations

– Electrical domain resources

• Network Connections

Page 279: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 279/3696 

11 - 11P. Raatikainen Switching Technology / 2003

Network links

A large number of concurrent connections can be supported on each networklink through successive levels of multiplexing

– Space division multiplexing in the fiber layer:

• a cable consists of several (sometimes more than 100) fibers, which

are used as bi-directional pairs

– Wavelength division multiplexing (WDM) in the optical layer:

• a fiber carries connections on many distinct wavelengths (λ-channels)

• assigned wavelengths must be spaced sufficiently apart to keep

neighboring signal spectra from overlapping (to avoid interference)

– Time division multiplexing (TDM) in the transmission channel sublayer:• a λ-channel is divided (in time) into frames and time-slots

• each time-slot in a frame corresponds to a transmission channel,

which is capable of carrying a logical connection

• location of a time-slot in a frame identifies a transmission channel

11 - 12P. Raatikainen Switching Technology / 2003

Fiber resources

{ Transmission channel out

λ-channels out...

...

...

...

Cable Fibers Wavebands

{ Transmission channel in

λ-channels

in

Space Wavelength Time

Page 280: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 280/369

Page 281: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 281/3698 

11 - 15P. Raatikainen Switching Technology / 2003

Wavelength and waveband partitioningof the optical spectrum

λ1,1   λ2,1   λ10,1

...

10 GHz

100 GHz/0.8 nm

w1 wmw2

100 GHz/0.08 nm

...f/λ

11 - 16P. Raatikainen Switching Technology / 2003

Network based on spectrum partitioning

 

λ1, λ2 ,..., λm

Single waveband

 λm

 λ2

 λ1

w1

w2

wm

Wavelength-routed

...

 λ1,m -λ10,m

 λ1,10 -λ10,2

 λ1,1 -λ10,1

w1

w2

wm

Waveband-routed

...

Page 282: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 282/3699 

11 - 17P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

– Network Links: Spectrum Partitioning

– Layers and Sublayers

– Optical Network Nodes

– Network Access Stations

– Electrical domain resources

• Network Connections

11 - 18P. Raatikainen Switching Technology / 2003

Layered view of optical network (1)

FIBERLAYER

OPTICALLAYER

FIBER SECTION

FIBER LINK

OPTICAL/WAVEBAND PATH

λ-CHANNEL

OPTICAL CONNECTION

TRANSMISSION CHANNEL

LOGICAL CONNECTION

LOGICAL PATH

VIRTUAL CONNECTION

Logical layer 

Physical layer 

Sub- layers

Page 283: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 283/369

Page 284: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 284/36911

11 - 21P. Raatikainen Switching Technology / 2003

Typical connection

ES = End SystemLSN = Logical Switching NodeNAS = Network Access NodeONN = Optical Network NodeOA = Optical Amplifier 

ONN

ONN

Virtual Connection

Logical Path

Logical Connection

Optical Connection

ONN ONN ONN

LSN

NAS

ES

LSN

NAS

LSN

NAS

ES

Logical Connection

Optical Connection

ONN

OA

OA

11 - 22P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

– Network Links: Spectrum Partitioning– Layers and Sublayers

– Optical Network Nodes

– Network Access Stations

– Electrical domain resources

• Network Connections

Page 285: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 285/36912 

11 - 23P. Raatikainen Switching Technology / 2003

Optical network nodes (1)

• Optical Network Node (ONN) operates in the optical pathsublayer connecting N input fibers to N outgoing fibers

• ONNs are in the optical domain

• Basic building blocks:

– wavelength multiplexer (WMUX)

– wavelength demultiplexer (WDMUX)

– directional coupler (2x2 switch)• static

• dynamic

– wavelength converter (WC)

1

2

1′

2′

 N N ′

input fibers output fibers

11 - 24P. Raatikainen Switching Technology / 2003

Optical network nodes (2)

• Static nodes

– without wavelength selectivity

• NxN broadcast star  (= star coupler )

• Nx1 combiner • 1xN divider 

– with wavelength selectivity

• NxN wavelength router  (= Latin router )

• Nx1 wavelength multiplexer  (WMUX)

• 1xN wavelength demultiplexer  (WDMUX)

Page 286: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 286/36913 

11 - 25P. Raatikainen Switching Technology / 2003

Optical network nodes (3)

• Dynamic nodes

– without wavelength selectivity (optical crossconnect (OXC))

• NxN permutation switch

• RxN generalized switch

• RxN linear divider-combiner  (LDC)

– with wavelength selectivity

• NxN wavelength selective crossconnect (WSXC) with M

wavelengths• NxN wavelength interchanging crossconnect (WIXC)

with M wavelengths

• RxN waveband selective LDC with M wavebands

11 - 26P. Raatikainen Switching Technology / 2003

Wavelength multiplexer anddemultiplexer 

WDMUX

λ1,…,λ4

λ1

λ2

λ3

λ4

WMUX

λ1,…,λ4

λ1

λ2

λ3

λ4

Page 287: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 287/36914 

11 - 27P. Raatikainen Switching Technology / 2003

Directional Coupler (1)

• Directional coupler  (= 2x2 switch) is an optical four-port

– ports 1 and 2 designated as input ports

– ports 1’ and 2’ designated as output ports

• Optical power

– enters a coupler through fibers attached to input ports,

– divided and combined linearly

– leaves via fibers attached to output ports

• Power relations for input signal powers P1 and P2 and output

powers P1′ and P2′ are given by

• Denote the power transfer matrix by A = [aij]

2221212

2121111

PaPaP

PaPaP

+=

+=

′  1

2

1′

2′

 a11

 a21

 a22

 a12

11 - 28P. Raatikainen Switching Technology / 2003

Directional Coupler (2)

• Ideally, the power transfer matrix  A is of the form

• If parameter α is fixed, the device is static, e.g. with α = 1/2 andsignals present at both inputs, the device acts as a 2x2 star coupler

• If α can be varied through some external control, the device is

dynamic or controllable, e.g. add-drop switch

• If only input port 1 is used (i.e., P2 = 0),

the device acts as a 1x2 divider 

• If only output port 1’ is used (and port 2’ isterminated), the device acts as a 2x1 combiner 

10 ,1

1≤≤

−=   α 

α α 

α α 

 A

1

2

1′

2′

1−α 

α 

α 

1−α 

Page 288: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 288/36915 

11 - 29P. Raatikainen Switching Technology / 2003

Add-drop switch

OT OR

Add-drop state

OT OR

Bar state

11 - 30P. Raatikainen Switching Technology / 2003

Broadcast star 

• Static NxN broadcast star  with Nwavelengths can carry

– N simultaneous multi-cast optical

connections (= full multipoint opticalconnectivity)

• Power is divided uniformly

• To avoid collisions each input signalmust use different wavelength

• Directional coupler realization

– (N/2) log2N couplers needed

1

2   2′

3

4

λ1

λ2

λ3

λ4

3′

4′

1′λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,

λ4

1/ N 1/ N 1/ N 

1/ N 

1

2

3

4

2′

3′

4′

1′1/21/2

1/21/2

1/21/2

broadcast star realizedby directional couplers

Page 289: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 289/36916 

11 - 31P. Raatikainen Switching Technology / 2003

Wavelength router 

• Static NxN wavelength router with N wavelengths can carry

– N2 simultaneous unicastoptical connections (= fullpoint-to-point opticalconnectivity)

• Requires

– N 1xN WDMUX’s

– N Nx1 WMUX’s

1

2   2′

3

4

3′

4′

1′λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,

λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,

λ4

WDMUX’s WMUX’s

11 - 32P. Raatikainen Switching Technology / 2003

Crossbar switch

• Dynamic RxN crossbar switch consists of

– R input lines

– N output lines

– RN crosspoints• Crosspoints implemented by

controllable optical couplers

– RN couplers needed

• A crossbar can be used as

– a NxN permutation switch(then R = N) or

– a RXN generalized switch

1

2

2′

3

4

3′ 4′1′

crossbar used asa permutation switch

Page 290: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 290/36917 

11 - 33P. Raatikainen Switching Technology / 2003

Permutation switch

• Dynamic NxN permutation switch(e.g. crossbar switch)

– unicast optical connections

between input and output ports

– N! connection states (if

nonblocking)

– each connection state can carry N

simultaneous unicast optical

connections– representation of a connection state

by a NxN connection matrix

1

2

3

4

2′ 3′ 4′1′

   i  n  p  u   t  p  o  r   t  s

output ports

1

1

1

1

1

2 2′

3

4

3′

4′

1′

11 - 34P. Raatikainen Switching Technology / 2003

Generalized switch

=otherwise ,0

onis)(switchif  ,1 i,ja   NRij

• Dynamic RxN generalized switch (e.g.

crossbar switch)

– any input/output pattern possible

– 2NR connection states

– each connection state can carry (at most)

R simultaneous multicast optical

connections

– a connection state represented by a RxNconnection matrix

• Input/output power relation P’ =  AP with

NxR power transfer matrix  A = [aij], where1

2

3

4

2′ 3′ 4′1′

   i  n  p  u   t  p  o  r   t  s

output ports

1

1

1

1

1

1

1 1

1

2   2′

3

4

3′

4′

1′1/ N 1/ N 1/ N 1/ N 

1/ R1/ R1/ R1/ R

Page 291: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 291/36918 

11 - 35P. Raatikainen Switching Technology / 2003

Linear Divider-Combiner (LDC)

• Linear Divider-Combiner  (LDC) isa generalized switch that

– controls power-dividing andpower-combining ratios

– less inherent loss than in crossbar

• Power-dividing and power-combining ratios

–  δij = fraction of power from input port  j directed to output port i’

–  σij = fraction of power from input port  j combined onto output port i

• In an ideal case of lossless couplers, we have constraints

• The resulting power transfer matrix  A = [aij] is such that

1 and 1   ==   ∑∑ j

iji

ij   σ δ 

ijijija   σ δ =

1

2   2′

3

4

3′

4′

1′δ11 δ21 δ31 δ41 

σ41 σ422σ433σ444

11 - 36P. Raatikainen Switching Technology / 2003

LDC and generalized switch realizations

directional couplers

δ - σ  linear divider-combiner 

Generalized optical switch

1xnsplitter

...

1 2 r 

n1 n2 nr  

21 22 2r  

11 12 1r  

1

2

n

...

...

rx1combiner

Page 292: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 292/36919 

11 - 37P. Raatikainen Switching Technology / 2003

Wavelength selective cross-connect(WSXC)

• Dynamic NxN wavelength selective crossconnect(WSXC) with M wavelengths

– includes N 1xM WDMUXs,M NxN permutation switches,and N Mx1 WMUXs

– (N!)M connection statesif the permutation switchesare nonblocking

– each connection state cancarry NM simultaneousunicast optical connections

– representation of a connectionstate by M NxN connection matrices

2′

3′

4′

1′

WDMUX’s WMUX’s

1

2

3

4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

optical switches

11 - 38P. Raatikainen Switching Technology / 2003

Wavelength interchanging cross-connect(WIXC)

• Dynamic NxN wavelength interchanging crossconnect(WIXC) with M wavelengths

– includes N 1xM WDMUXs, 1 NM x NM permutationswitch, NM WCs, and N Mx1 WMUXs

– (NM)! connection states ifthe permutation switch isnonblocking

– each connection state cancarry NM simultaneousunicast connections

– representation of a connectionstate by a NMxNMconnection matrix WDMUX’s WMUX’s

optical switch

WC’s

1

2   2′

3

4

3′

4′

1′λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

λ1,… ,λ4

Page 293: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 293/36920 

11 - 39P. Raatikainen Switching Technology / 2003

Waveband selective LDC

• Dynamic RxN waveband selective LDC with M wavebands

– includes R 1xM WDMUXs, M RxN LDCs, and N Mx1 WMUXs

– 2RNM connection states (if usedas a generalized switch)

– each connection state cancarry (at most) RMsimultaneous multi-castconnections

– representation of aconnection state by a M RxNconnection matrices

WDMUX’s WMUX’s

2′

3′

4′

1′1

2

3

4

w1,… ,w4

w1,… ,w4

w1,… ,w4

w1,… ,w4

w1,… ,w4

w1,… ,w4

w1,… ,w4

w1,… ,w4

LDC’s

11 - 40P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

– Network Links: Spectrum Partitioning– Layers and Sublayers

– Optical Network Nodes

– Network Access Stations

– Electrical domain resources

• Network Connections

Page 294: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 294/36921

11 - 41P. Raatikainen Switching Technology / 2003

Network access stations (1)

• Network Access Station (NAS) operates in the logical

connection, transmission channel and λ-channel sublayers

• NASs are the gateways between the electrical and opticaldomains

• Functions:

– interfaces the external LC ports tothe optical transceivers

– implements the functions necessaryto move signals between the electricaland optical domains

electronic wires optical fibers

1

2

1′

 L

 L′

2′

e/o

 a

 a’

11 - 42P. Raatikainen Switching Technology / 2003

Network access stations (2)

• Transmitting side components:

– Transmission Processor  (TP) with a number of LC input ports andtransmission channel output ports connected to optical transmitters(converts each logical signal to a transmission signal)

– Optical Transmitters (OT) with a laser modulated by transmissionsignals and connected to a WMUX (generates optical signals)

– WMUX multiplexes the optical signals to an outbound access fiber

• Receiving side components:

– WDMUX demultiplexes optical signals from an inbound access fiber and

passes them to optical receivers

– Optical Receivers (OR) convert optical power to electrical transmissionsignals, which are corrupted versions of the original transmitted signals

– Reception Processor  (RP) converts the corrupted transmission signals

to logical signals (e.g. regenerating digital signals)

Page 295: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 295/36922 

11 - 43P. Raatikainen Switching Technology / 2003

Elementary network access station

TP

RP

OT

OT

OR

OR

ONN

NAS

WMUX

WDMUX

e/o

access fiber pair 

   l  o  g   i  c  a   l  c  o  n  n  e  c   t   i  o  n  p  o  r   t  s

internodal fiber pairs

11 - 44P. Raatikainen Switching Technology / 2003

Nonblocking network access station

TP

RP

ONN

NAS

WMUX’s

WDMUX’s

e/o

OT

OT

OR

OR

   l  o  g   i  c  a   l  c  o  n  n  e  c   t   i  o  n

  p  o  r   t  s

access fiber pairs

internodal fiber pairs

Page 296: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 296/36923 

11 - 45P. Raatikainen Switching Technology / 2003

Wavelength add-drop multiplexer (WADM)

OT

λ1

λ2

λm

OR

...

λ1

OT OR

λ2

OT OR

λm

...

TP/RP

...

NAS

WADM

   W   D   M   U   X

   W   M   U   X

11 - 46P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

– Network Links: Spectrum Partitioning– Layers and Sublayers

– Optical Network Nodes

– Network Access Stations

– Electrical domain resources

• Network Connections

Page 297: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 297/36924 

11 - 47P. Raatikainen Switching Technology / 2003

End System

• End systems are in the electrical domain

• In transparent optical networks, they aredirectly connected to NASs

– purpose is to create full logicalconnectivity between end stations

• In hybrid networks, they are connected toLSNs

– purpose is to create full virtualconnectivity between end stations

access wires

 a

 a’

11 - 48P. Raatikainen Switching Technology / 2003

Logical Switching Node (LSN)

• Logical switching nodes (LSN) are needed in hybrid networks,i.e. logically routed networks (LRN)

• LSNs are in the electrical domain

• They may be e.g.– SONET digital cross-connect systems

(DCS), or

– ATM switches, or

– IP routers

1

2

1′

2′

 N N ′

input wires output wires

Page 298: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 298/36925 

11 - 49P. Raatikainen Switching Technology / 2003

Logically routed network

Physical layer   

Logical layer 

LS

NAS

ONN

LSN

Logicallyswitchingnode

LSN - Logically Switching NodeLS - Logical SwitchNAS - Network Access StationONN - Optical Network Node

11 - 50P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

• Network Connections

– Connectivity

– Connections in various layers

– Example: realizing full connectivity between fiveend systems

Page 299: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 299/36926 

11 - 51P. Raatikainen Switching Technology / 2003

Connectivity

• Transmitting side:

– one-to-one

• (single) unicast

– one-to-many

• multiple unicasts

• (single) multicast

• multiple multicasts

• Network wide:

– point-to-point

– multipoint

• Receiving side:

– one-to-one

• (single) unicast

• (single) multicast

– many-to-one

• multiple unicasts

• multiple multicasts

11 - 52P. Raatikainen Switching Technology / 2003

Connection Graph (CG)

• Representing point-to-point connectivity between end systems

1

Connection graph

2

4 3

  Bipartite representation

1

2

4

3

1

2

4

3

transmittingside

receivingside

Page 300: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 300/36927 

11 - 53P. Raatikainen Switching Technology / 2003

Connection Hypergraph (CH)

• Representing multipoint connectivity between end systems

1

Connection hypergraph

2

4 3

E1

E2

Tripartite representation

1

2

4

3

1

2

4

3

transmittingside

receivingside

E1

hyper-edges

E2

11 - 54P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

• Network Connections– Connectivity

– Connections in various layers

– Example: realizing full connectivity between fiveend systems

Page 301: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 301/36928 

11 - 55P. Raatikainen Switching Technology / 2003

Connections in various layers

• Logical connection sublayer

– Logical connection (LC) is a unidirectional connection betweenexternal ports on a pair of source and destination networkaccess stations (NAS)

• Optical connection sublayer

– Optical connection (OC) defines a relation between onetransmitter and one or more receivers, all operating in the samewavelength

• Optical path sublayer– Optical path (OP) routes the aggregate power on one waveband

on a fiber, which could originate from several transmitters withinthe waveband

11 - 56P. Raatikainen Switching Technology / 2003

Notation for connections in variouslayers

• Logical connection sublayer

– [a, b] = point-to-point logical connection from an external port on station a

to one on station b

– [a, {b, c, …}] = multi-cast logical connection from a to set {b, c, …}

• station a sends the same  information to all receiving stations• Optical connection sublayer

– (a, b) = point-to-point optical connection from station a to station b

– (a, b)k  = point-to-point optical connection from a to b using wavelength λk 

– (a,{b,c,…}) = multi-cast optical connection from a to set {b,c,…}

• Optical path sublayer

– ⟨a, b⟩ = point-to-point optical path from station a to station b

– ⟨a, b⟩k  = point-to-point optical path from a to b using waveband wk 

– ⟨a, {b, c, …}⟩ = multi-cast optical path from a to set {b,c,…}

Page 302: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 302/36929 

11 - 57P. Raatikainen Switching Technology / 2003

Example of a logical connection betweentwo NASs

ONN

TP RP

Electrical Electrical

Optical Opticalλ1 ... λm  λm ... λ1 

WMUX WDMUX

OT OR

NAS NAS

w2 ONN

ONNw1

Logical connection [A,B]

Transmission channel

Optical connection (A,B)λ1

λ-channel

Optical path <A,B>w1

11 - 58P. Raatikainen Switching Technology / 2003

Contents

• The Big Picture

• Network Resources

• Network Connections– Connectivity

– Connections in various layers

– Example: realizing full connectivity betweenfive end systems

Page 303: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 303/36930 

11 - 59P. Raatikainen Switching Technology / 2003

Example: realization of full connectivitybetween 5 end systems

5 2

4 3

1

11 - 60P. Raatikainen Switching Technology / 2003

Solutions

• Static network based on star physical topology

– full connectivity in the logical layer (20 logical connections)

– 4 optical transceivers per NAS, 5 NASs, 1 ONN (broadcast star)

– 20 wavelengths for max throughput by WDM/WDMA

• Wavelength routed network (WRN) based on bi-directional ring physical

topology

– full connectivity in the logical layer (20 logical connections)

– 4 optical transceivers per NAS, 5 NASs, 5 ONNs (WSXCs)

– 4 wavelengths (assuming elementary NASs)

• Logically routed network (LRN) based on star physical topology andunidirectional ring logical topology

– full connectivity in the virtual layer but only partial connectivity in the logicallayer (5 logical connections)

– 1 optical transceiver per NAS, 5 NASs, 1 ONN (WSXC), 5 LSNs

– 1 wavelength

Page 304: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 304/36931

11 - 61P. Raatikainen Switching Technology / 2003

Static network realization

5x5 broadcast starLCG

1

2

3

4

5

1

25

4 3

1

25

4 3

11 - 62P. Raatikainen Switching Technology / 2003

Wavelength routed network realization

3x3 WSXC1

2

3

4

5

1

25

4 3

1

25

4 3

LCG

Page 305: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 305/36932 

11 - 63P. Raatikainen Switching Technology / 2003

Logically routed network realization

5x5 WSXC

LSN

1

2

3

4

5

1

25

4 3

1

25

4 3

LCG

Page 306: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 306/369

12 - 1P. Raatikainen Switching Technology / 2003

Multiwavelength OpticalNetwork Architectures

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

Source: Stern-Bala (1999), Multiwavelength Optical Networks

12 - 2P. Raatikainen Switching Technology / 2003

Router implementations

• Static networks

• Wavelength Routed Networks (WRN)• Linear Lightwave Networks (LLN)

• Logically Routed Networks (LRN)

Page 307: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 307/369

12 - 3P. Raatikainen Switching Technology / 2003

Static networks

• Static network, also called broadcast-and-select network, is apurely optical shared medium network

• passive splitting and combining nodes are interconnected by fibers toprovide static connectivity among some or al l OTs and ORs

• OTs broadcast and ORs select

• Broadcast star network is an example of such a static network

• star coupler combines all signals and broadcasts them to all ORs- static optical multi-cast paths from any station to the set of all stations

- no wavelength selectivity at the network node

• optical connection is created by tuning the source OT and/or destinationOR to the same wavelength

• two OTs must operate at different wavelengths (to avoid interference)- this is called the distinct channel assignment (DCA) constraint

• however, two ORs can be tuned to the same wavelength- by this way, optical multi-cast connections are created

12 - 4P. Raatikainen Switching Technology / 2003

Realization of logical connectivity

• Methods to realize full point-to-point logical connectivity in abroadcast star with N nodes:

• WDM/WDMA- a whole λ-channel allocated for each LC

- N(N-1) wavelengths needed (one for each LC)

-N-1 transceivers needed in each NAS

• TDM/TDMA- 1/[N(N-1)] of a λ-channel allocated for each LC

- 1 wavelength needed

- 1 transceiver needed in each NAS

• TDM/T-WDMA- 1/(N-1) of a λ-channel allocated for each LC

- N wavelengths needed (one for each OT)

- 1 transceiver needed in each NAS, e.g. fixed OT and tunable OR(FT-TR), or tunable OT and fixed OR (TT-FR)

Page 308: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 308/369

12 - 5P. Raatikainen Switching Technology / 2003

Broadcast star using WDM/WDMA

TPOT

star coupler 

OT

TPOT

OT

TPOT

OT

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

LCs

RPOR

OR

RPOR

OR

RPOR

OR

[2,1]

[3,1]

[1,2]

[3,2]

[1,3]

[2,3]

LCsNAS 1

λ1

λ2

λ3

λ4

λ5

λ6

λ3

λ5

λ1

λ6

λ2

λ4

λ1,2

λ3,4

λ5,6

λ1-6

λ1-6

λ1-6

12 - 6P. Raatikainen Switching Technology / 2003

Broadcast star using TDM/TDMA

TP OT

TP OT

TP OT

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

LCs

RPOR

RPOR

RPOR

LCsNAS 1

λ1

λ1

λ1

λ1

λ1

λ1

[2,1]

[3,1]

[1,2]

[3,2]

[1,3]

[2,3]

star coupler 

Page 309: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 309/369

12 - 7P. Raatikainen Switching Technology / 2003

Effect of propagation delay onTDM/TDMA

A TDM/TDMA schedule

[1,2]1 [1,2]2 [1,3]1 [1,2]1 [1,2]2 [1,3]1

[2,3]1

From 1 From 1

[2,3]2

From 2 From 2

From 1 From 1From 2 From 2

From 1 From 1From 2 From 2

OT1

OT2

OR2

OR3

Coupler 

F1 F2

F1 F2

F1 F2

12 - 8P. Raatikainen Switching Technology / 2003

Broadcast star using TDM/T-WDMA inFT-TR mode

TP OT

TP OT

TP OT

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

LCs

RPOR

RPOR

RPOR

LCsNAS 1

λ1

λ2

λ3

λ1-3

λ1-3

λ1-3

fixed tunable

[2,1]

[3,1]

[1,2]

[3,2]

[1,3]

[2,3]

star coupler 

λ2

λ3

λ1

λ3

λ1

λ2

Page 310: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 310/369

12 - 9P. Raatikainen Switching Technology / 2003

Broadcast star using TDM/T-WDMA inTT-FR mode

TP OT

TP OT

TP OT

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

LCs

RPOR

RPOR

RPOR

LCsNAS 1

λ2,3

λ1,3

λ1,2

λ1-3

λ1-3

λ1-3

tunable fixed

[2,1]

[3,1]

[1,2]

[3,2]

[1,3]

[2,3]

star coupler 

λ1

λ2

λ3

λ2

λ3

λ3

λ1

λ1

λ2

12 - 10P. Raatikainen Switching Technology / 2003

Channel allocation schedules for circuitswitching

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

WDM/WDMA

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

λ1

λ2

λ3

λ4

λ5

λ6

frame

TDM/TDMA

[1,2] [1,3] [2,1]λ1 [2,3] [3,1] [3,2] [1,2] [1,3] [2,1] [2,3] [3,1] [3,2]

frame

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

[1,2]

[2,3]

[3,1]

TDM/T-WDMA with FT-TR

[1,3]

[2,1]

[3,2]

[1,2]

[2,3]

[3,1]

λ1

λ2

λ3

frame

[1,3]

[2,1]

[3,2]

[2,1]

[3,2]

[1,3]

TDM/T-WDMA with TT-FR

[3,1]

[1,2]

[2,3]

[2,1]

[3,2]

[1,3]

λ1

λ2

λ3

frame

[3,1]

[1,2]

[2,3]

Channel allocation schedule (CAS) should be- realizable = only one LC per each OT and time-slot

- collision-free = only one LC per each λ and time-slot

- conflict-free = only one LC per each OR and time-slot

Page 311: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 311/369

12 - 11P. Raatikainen Switching Technology / 2003

Packet switching in the optical layer 

• Fixed capacity allocation, produced by periodic frames, is welladapted to stream-type traffic. However, in the case of bursty packettraffic this approach may produce a very poor performance

• By implementing packet switching in the optical layer , it ispossible to maintain a very large number of LCs simultaneously

using dynamic capacity allocation- packets are processed in TPs/RPs of the NASs (but not in ONNs)

- TPs can schedule packets based on instantaneous demand

- as before, broadcast star is used as a shared medium

- control of this shared optical mediumrequires a Medium AccessControl (MAC) protocol

TP

RP

OT

OR

ONNMACNAS equipped for packet switching

12 - 12P. Raatikainen Switching Technology / 2003

Additional comments on static networks

• The broadcast-and-select principle cannot be scaled to largenetworks for three reasons:

 – Spectrum use: Since all transmissions share the same fibers, thereis no possibility of optical spectrum reuse => the required spectrum

typically grows at least proportionally to the number of transmittingstations

 – Protocol complexity: Synchronization problems, signalingoverhead, time delays, and processing complexity all increaserapidly with the number of stations and with the number of LCs.

 – Survivability: There are no alternate routes in case of a failure.Furthermore, a failure at the star coupler can bring the wholenetwork down.

 – For these reasons, a practical limit on the number of stations in abroadcast star is approximately 100

Page 312: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 312/369

12 - 13P. Raatikainen Switching Technology / 2003

Contents

• Static networks

• Wavelength Routed Networks (WRN)

• Linear Lightwave Networks (LLN)

• Logically Routed Networks (LRN)

12 - 14P. Raatikainen Switching Technology / 2003

Wavelength Routed Networks (WRN)

• Wavelength routed network (WRN) is a purely optical network

 – each λ-channel can be recognized in the ONNs (= wavelength

selectivity) and routed individually

 – ONNs are typically wavelength selective crossconnects (WSXC)

• network is dynamic (allowing switched connections)

• a static WRN (allowing only dedicated connections) can be built upusing static wavelength routers

• All optical paths and connections are point-to-point

 – each point-to-point LC corresponds to a point-to-point OC

 – full point-to-point logical/optical connectivity among N stations requiresN-1 transceivers in each NAS

 – multipoint logical connectivity only possible by several point-to-pointoptical connections using WDM/WDMA

Page 313: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 313/369

12 - 15P. Raatikainen Switching Technology / 2003

Static wavelength routed star 

• Full point-to-point logical/optical connectivity in a staticwavelength routed star with N nodes can be realized by

 – WDM/WDMA

• a whole λ-channel allocated for each LC

• N-1 wavelengths needed- spectrum reuse factor is N  (= N(N-1) optical connections / N-1 wavelengths)

• N-1 transceivers needed in each NAS

12 - 16P. Raatikainen Switching Technology / 2003

Static wavelength routed star usingWDM/WDMA

TPOT

wavelength router 

OT

TPOT

OT

TPOT

OT

[1,2]

[1,3]

[2,1]

[2,3]

[3,1]

[3,2]

LCs

RPOR

OR

RPOR

OR

RPOR

OR

[2,1]

[3,1]

[1,2]

[3,2]

[1,3]

[2,3]

LC’NAS 1

λ1

λ2

λ2

λ1

λ1

λ2

λ2

λ1

λ1

λ2

λ2

λ1

λ1,2

λ1,2

λ1,2

λ1,2

λ1,2

λ1,2

Page 314: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 314/369

12 - 17P. Raatikainen Switching Technology / 2003

Routing and channel assignment

• Consider a WRN equipped with WSXCs (or wavelength routers)

 – no wavelength conversion possible

• Establishing an optical connection requires

 – channel assignment

 – routing

• Channel assignment (executed in the λ-channel sublayer) involves

 – allocating an available wavelength to the connection and

 – tuning the transmitting and receiving station to the assigned wavelength

• Routing (executed in the optical path sublayer) involves

 – determining a suitable optical path for the assigned λ-channel and

 – setting the switches in the network nodes to establish that path

12 - 18P. Raatikainen Switching Technology / 2003

Channel assignment constraints

• Following two channel assignment constraints apply to WRNs

• wavelength continuity: wavelength of each optical connectionremains the same on all links it traverses from source to destination

• this is unique to transparent optical networks, making routing and

wavelength assignment a more challenging task than the relatedproblem in conventional networks

• distinct channel assignment (DCA): all opticalconnections sharing a common fiber must be

assigned distinct λ-channels (i.e. distinct wavelengths)

- this applies to access links as well as internodal links- although DCA is necessary to ensure distinguishabilityof signals on the same fiber, it is possible (and generallyadvantageous) to reuse the same wavelength on

fiber-disjoint paths

1

2

3

1

2

3

1

2

3

1

2

3

Page 315: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 315/369

12 - 19P. Raatikainen Switching Technology / 2003

Routing and Channel Assignment (RCA)problem

• Routing and channel assignment (RCA) is the fundamentalcontrol problem in large optical networks

 – Generally, the RCA problem for dedicated connections can be treatedoff-line => computationally intensive optimization techniques are

appropriate

 – On the other hand, RCA decisions for switched connections must bemade rapidly, and hence suboptimal heuristics must normally be used

dedicated

1 3 5

2 4 6

switched 1

1 3 5

2 4 6

(1,3)1 (3,5)1

(4,6)2

switched 2

1 3 5

2 4 6

(1,3)1 (3,5)1

(4,6)2

12 - 20P. Raatikainen Switching Technology / 2003

Example bi-directional ring withelementary NASs

• Consider a bi-directional ring of 5 nodes andstations with single access fiber pairs

• Full point-to-point logical/optical connectivityrequires

- 4 wavelengths => spectrum reuse factor is20/4 = 5- 4 transceivers in each NAS

RCA

2L 3L 4R 1R --

4L 2R 1R -- 3L

3R 4R -- 2L 1L

1R -- 3L 4L 2R

-- 1L 2L 3R 4R

1 2 3 4 5

5

4

3

2

11 523

12

Fiber from ONN1 to ONN2

1

2

3 4

5L R

physical topology

Page 316: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 316/369

12 - 21P. Raatikainen Switching Technology / 2003

Example bi-directional ring withnonblocking NASs

• Consider a bi-directional ring of 5 nodes andstations with two access fiber pairs

• Full point-to-point logical/optical connectivityrequires

- 3 wavelengths => spectrum reuse factor is20/3 = 6.67- 4 transceivers in each NAS

RCA

1L 3L 1R 3R --

2L 3R 2R -- 3L

2R 1R -- 2L 1L

1R -- 1L 3L 3R-- 1L 2L 2R 1R

1 2 3 4 5

5

4

3

211 523

12

Fiber from ONN1 to ONN2

1

2

3 4

5L R

physical topology

12 - 22P. Raatikainen Switching Technology / 2003

Example mesh network with elementaryNASs

• Consider a mesh network of 5 nodes andstations with single access fiber pairs

• Full point-to-point logical/optical

connectivity requires – 4 wavelengths

=> spectrum reuse factor is 20/4 = 5

 – 4 transceivers in each NAS

 – despite the richer physical topology, nodifference with the corresponding bi-directional ring (thus, the access fibersare the bottleneck)

RCA?

5

1 2

4 3

physical topology

Page 317: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 317/369

12 - 23P. Raatikainen Switching Technology / 2003

Example mesh network with nonblockingNASs

• Consider a mesh network of 5 nodes andstations with three/four access fiber pairs

• Full point-to-point logical/opticalconnectivity requires

 – only 2 wavelengths=> spectrum reuse factor is 20/2 = 10

 – 4 transceivers in each NAS

RCA?

5

1 2

4 3

physical topology

12 - 24P. Raatikainen Switching Technology / 2003

Contents

• Static networks

• Wavelength Routed Networks (WRN)• Linear Lightwave Networks (LLN)

• Logically Routed Networks (LRN)

Page 318: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 318/369

12 - 25P. Raatikainen Switching Technology / 2003

Linear Lightwave Networks (LLN)

• Linear lightwave network (LLN) is a purely optical network

 – nodes perform (only) strictly linear operations on optical signals

• This class includes

 – both static and wavelength routed networks

 – but also something more

• The most general type of LLN has waveband selective LDC nodes

 – LDC performs controllable optical signal dividing, routing and combining

 – these functions are required to support multipoint optical connectivity

• Waveband selectivity in nodes means that – optical path layer routes signals as bundles that contain all λ-channels

within one waveband

• Thus, all layers of connectivity and their interrelations must beexamined carefully

12 - 26P. Raatikainen Switching Technology / 2003

Routing and channel assignmentconstraints

• Two constraints of WRNs need also to be satisfied by LLNs

• Wavelength continuity: wavelength of each optical connection remainsthe same on all the links it traverses from source to destination

• Distinct channel assignment (DCA): all optical connections sharing a

common fiber must be assigned distinct λ-channels

• Additionally, the following two routing constraints apply to LLNs

• Inseparability: channels combined on a single fiber and situated withinthe same waveband cannot be separated within the network

- this is a consequence of the fact that the LDCs operate on theaggregate power carried within each waveband

• Distinct source combining (DSC): only signals from distinct sourcesare allowed to be combined on the same fiber- DSC condition forbids a signal from splitting, taking multiple paths, and then

recombining with itself

- otherwise, combined signals would interfere with each other

Page 319: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 319/369

12 - 27P. Raatikainen Switching Technology / 2003

Inseparability

H

A B

D E

C

GF

S1

S2

S1

S2a

1

2

3

1*

2*

3*

H

A B

D E

C

GF

S2

S1

S2

a

1

2

3

1*

2*

3*

S1

12 - 28P. Raatikainen Switching Technology / 2003

Two violations of DSC

A

C

B

A

C

B

Page 320: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 320/369

12 - 29P. Raatikainen Switching Technology / 2003

Inadvertent violation of DSC

H

A B

D E

C

GF

S3

S1 + S2S1

d

1

2

3

1*

2*

3*S1 + S2

S1 + S2 + S3

S1 + S2 + S3

S1 + S2 + S3

S2

12 - 30P. Raatikainen Switching Technology / 2003

Avoidance of DSC violations

H

A B

D E

C

GF

S3

S1S1

1

2

3

1*

2*

3*

S2 + S3

S2 + S3S2

H

A B

D E

C

GF

S3

S1 + S2 + S3

S1

d

1

2

3

1*

2*

3*

S1 + S2

S1 + S2 + S3

S2

a

bh

c

Page 321: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 321/369

12 - 31P. Raatikainen Switching Technology / 2003

Color clash

H

A B

D E

C

GF

S1S1

1

2

3

1*

2*

3*S2

(1, 1*)1

(2, 2*)1

d

H

A B

D E

C

GF

S3

S1S1

1

2

3

1*

2*

3*S2 + S3S2

d

S2

(3, 3*)2

12 - 32P. Raatikainen Switching Technology / 2003

Power distribution

• In a LDC it is possible to specify combining and dividing ratios

• ratios determine how power from sources is distributed to destinations

• combining and dividing ratios can be set differently for each waveband

• How should these ratios be chosen?

• The objective could be• to split each source’s power equally among all destinations it reaches

• to combine equally all sources arriving at the same destination

• Resultant end-to-end power transfer coefficients are independent of

• routing paths through the network

• number of nodes they traverse

• order in which signals are combined and split

• Coefficients depend only on

• number of destinations for each source

• number of sources reaching each destination

Page 322: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 322/369

12 - 33P. Raatikainen Switching Technology / 2003

Illustration of power distribution

1/3

2/31

(1/2)(S1+ S2) a a’

S3  b’ b (1/6) )(S1+ S2)

2/3

h h’

c c’ (2/9) )(S1+ S2)+(1/3) S3 

1

1/3

12 - 34P. Raatikainen Switching Technology / 2003

Multipoint subnets in LLNs

• Attempts to set up several point-to-point optical connections within acommon waveband leads to unintentional creation of multipoint paths=> complications in routing, channel assignment and power distribution

• On the other hand, waveband routing leads to more efficient use of

the optical spectrum• In addition, the multipoint optical path capability is useful when

creating intentional multipoint optical connections

 – LLNs can deliver a high degree of logical connectivity with minimal

optical hardware in the access stations

 – this is one of the fundamental advantages of LLNs over WRNs

• Multipoint optical connections can be utilized when creating a fulllogical connectivity among specified clusters of stations within alarger network => such fully connected clusters are called

multipoint subnets (MPS)

Page 323: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 323/369

12 - 35P. Raatikainen Switching Technology / 2003

Example - seven stations on a mesh

• Consider a network containing sevenstations interconnected on a LLN witha mesh physical topology and bi-directional fiber links- notation for fiber labeling: a  and a´  form

a fiber pair with opposite directions

• Set of stations {2,3,4} should beinterconnected to create a MPS withfull logical connectivity

• This can be achieved, e.g. by creatingan optical path on a singlewaveband in the form of a tree joiningthe three stations (embeddedbroadcast star )

2

3

4

2

3

4

LCG

2

3

4

2

3

4

LCH

E

A B

D C

1

6

2

3

4

5

71

6

4

5

2

7 a

e

 f 

 h

 g

 b´ 

 d c

physical topology

12 - 36P. Raatikainen Switching Technology / 2003

Realization of MPS by a tree embeddedin mesh

g’

3

B

C

D

B

D

2

4

3

2

4

3’

2’

4’

3

2

4

g

f’f 

g’

c’

3’

f ’

g

c

3

3

4

2

CD

B

Optical path

gc

Page 324: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 324/369

12 - 37P. Raatikainen Switching Technology / 2003

Contents

• Static networks

• Wavelength Routed Networks (WRN)

• Linear Lightwave Networks (LLN)

 – Seven-station example

• Logically Routed Networks (LRN)

12 - 38P. Raatikainen Switching Technology / 2003

Seven-station example

• Assume:

 – nonblocking access stations

 – each transmitter runs at a bit rate of R 0

• Physical topologies (PT):

 – bi-directional ring – mesh

 – multistar  of seven physical stars

• Logical topologies (LT):

 – fully connected (point-to-point logical topology with 42 edges)- realized using WRN

 – fully shared  (hypernet logical topology with a single hyperedge)

- realized using a broadcast-and-select network (LLN of a single MPS)

 – partially shared (hypernet of seven hyperedges)- realized using LLN of seven MPSs

Page 325: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 325/369

12 - 39P. Raatikainen Switching Technology / 2003

Physical topologies

multistar 

D

E

F

G

C

B

A1

2

3

4

5

6

7

ring

7   

 6

5   4

  2

1

A

B

D E

G

C F

mesh

A B

D C

1

6

2

3

4

5

7

E

12 - 40P. Raatikainen Switching Technology / 2003

Fully connected LT - WRN realizations

• Ring PT:

 – 6 λs with spectrum reuse factor of 42/6 = 7=> RCA?

 – 6 transceivers in each NAS⇒ network capacity = 7*6 = 42 R 0

• Mesh PT:

 – 4 λs with spectrum reuse factor of 42/4 = 10.5=> RCA?

 – 6 transceivers in each NAS ⇒ network capacity = 7*6 = 42 R 0

• Multistar  PT:

 – 2 λs with spectrum reuse factor of 42/2 = 21=> RCA?

 – 6 transceivers in each NAS ⇒ network capacity = 7*6 = 42 R 0

1

2

3

4

5

6

7

1

2

3

4

5

6

7

LCG

Page 326: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 326/369

12 - 41P. Raatikainen Switching Technology / 2003

Fully shared LT - Broadcast and selectnetwork realizations

• Any PT

• WDM/WDMA:

 – 42 λs with spectrum reuse factor of 1

 – 6 transceivers in each NAS

 ⇒ network capacity = 7*6 = 42 R 0

• TDM/T-WDMA in FT-TR mode:

 – 7 λs with spectrum reuse factor of 1

 – 1 transceiver in each NAS

 ⇒

 network capacity = 7*1 = 7R 

0• TDM/TDMA:

 – 1 λ with spectrum reuse factor of 1

 – 1 transceiver in each NAS

 ⇒ network capacity = 7*1/7 = 1 R 0 LCH

1

2

3

4

5

6

7

1

2

3

4

5

6

7

 E1

12 - 42P. Raatikainen Switching Technology / 2003

Partially shared LT - LLN realizations

• Note: Full logical connectivity among all stations

• Mesh PT using TDM/T-WDMA in FT-TR mode:

 – 2 wavebands with spectrum reuse factor of7/2 = 3.5 => RCA?

 – 3λ

s per waveband – 3 transceivers in each NAS

 ⇒ network capacity = 7*3 = 21 R 0

• Multistar  PT using TDM/T-WDMA in FT-TRmode:

 – 1 waveband with spectrum reuse factor of 7/1 = 7=> RCA?

 – 3 λs per waveband

 – 3 transceivers in each NAS

 ⇒ network capacity = 7*3 = 21 R 0 LCH

1

2

3

4

5

6

7

1

2

3

4

5

6

7

 E1

 E2

 E3

 E4

 E5

 E6

 E7

Page 327: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 327/369

12 - 43P. Raatikainen Switching Technology / 2003

Contents

• Static networks

• Wavelength Routed Networks (WRN)

• Linear Lightwave Networks (LLN)

• Logically Routed Networks (LRN)

12 - 44P. Raatikainen Switching Technology / 2003

Logically Routed Networks (LRN)

• For small networks, high logical connectivity is reasonably achievedby purely optical networks. However, when moving to largernetworks, the transparent optical approach soon reaches its limits.

• For example, to achieve full logical connectivity among 22 stations ona bi-directional ring using wavelength routed point-to-point optical

connections 21 transceivers are needed in each NAS and totally 61wavelengths. Economically and technologically, this is well beyondcurrent capabilities.=> we must turn to electronics (i.e. logically routed networks)

• Logically routed network (LRN) is a hybrid optical network

 – which performs logical switching (by logical switching nodes(LSN)) on top of a transparent optical network

 – LSNs create an extra layer of connectivity between the endsystems and NASs

Page 328: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 328/369

12 - 45P. Raatikainen Switching Technology / 2003

Two approaches to create fullconnectivity

• Multihop networks based on point-to-point logicaltopologies

 – realized by WRNs

• Hypernets based on multipoint logical topologies

 – realized by LLNs

12 - 46P. Raatikainen Switching Technology / 2003

Point-to-point logical topologies

• In a point-to-point logical topology – a hop corresponds to a logical link between two LSNs

 – maximum throughput is inversely proportional to the average hop count

• One of the objectives of using logical switching on top of atransparent optical network is

 – to reduce cost of station equipment (by reducing the number of opticaltransceivers and complexity of optics) while maintaining high networkperformance

• Thus, we are interested in logical topologies that – achieve a small average number of logical hops at a low cost (i.e., small

node degree and simple optical components)

• An example is a ShuffleNet – for example, an eight-node ShuffleNet has 16 logical links and an

average hop count of 2 (if uniform traffic is assumed)

 – these networks are scalable to large sizes by adding stages and/orincreasing the degree of the nodes

Page 329: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 329/369

Page 330: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 330/369

12 - 49P. Raatikainen Switching Technology / 2003

Details of a ShuffleNet node

L

R

1

λ1, λ2

λ2

λ1, λ2

λ2

λ1, λ2

λ1, λ2

L

R

1

ONN1

1 256

15

L

R

Fibers between ONN5 and ONN1

1

5

6

5

6

1 1

2 2

OT1 OT2

TP TP

OR1 OR2

RP RP

1

1 2 1 2

12 - 50P. Raatikainen Switching Technology / 2003

Multipoint logical topologies

• High connectivity may be maintained in transparent optical networkswhile economizing on optical resource utilization through the use ofmultipoint connections

• These ideas are even more potent when combined with logicalswitching

• For example, a ShuffleNet may be modified to a Shuffle Hypernet – an 8-node Shuffle Hypernet has 4 hyperarcs

 – each hyperarc presents a directed MPS that contains 2 transmitting and2 receiving stations

 – an embedded directed broadcast star is created to support each MPS

 – for a directed star, a (physical) tree is found joining all stations in both thetransmitting and receiving sets of the MPS

 – any node on the tree can be chosen as a root

 – LDCs on the tree are set to create optical paths from all stations in thetransmitting set to the root node, and paths from the root to all receivingstations

Page 331: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 331/369

12 - 51P. Raatikainen Switching Technology / 2003

Eight-node Shuffle Hypernet

LCH

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

 E1

 E2

 E3

 E4

transformation

1

2

3

4

1

2

3

4

5

6

7

8

 E1

12 - 52P. Raatikainen Switching Technology / 2003

Shuffle Hypernet embedded in a bi-directional ring LLN

• Bi-directional ring LLN with elementaryNASs using TDM/T-WDMA in FT-TR mode

 – 1 waveband with spectrum reuse factorof 4/1 = 4

 – 2 λs per waveband – 1 transceiver in each NAS

 ⇒ network cap. = 8*1/2 = 4 R 0

Note: station and fiber labeling!

1

4

6 7

   2

   3

   5

   8

 a a´

 b

 c

 d 

 h

 g

 f 

e4 4´

RCA

 a,  b´,  c´

inboundfibers

E4

E3

E2

E1 ONN5

root

 b

outboundfibers

 g,  a´,  h´ ONN2   he,  f ́ ,  g´ ONN8   f 

 c,  d´ , e´ ONN3   d 

1

wave-band

11

1

Page 332: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 332/369

12 - 53P. Raatikainen Switching Technology / 2003

Details of node in Shuffle Hypernet

 a

 b´ 

5

w1

w1

w1

w1

w1

ONN5

 a´ 

 b

5´w

1

Fibers between ONN3 and ONN1

5 163

56

 b´

3 1

 b a

 a´

 c

 c´

6   6´ 5   5´   1 1´3 3´

1

OT

TP

OR

RP

...

7, 1 1, 6

7, 2 1, 6

7, 1

5, 2

7, 27, 15, 2

5

7 2

1

3

5

6

3, 51, 6

E2

E1

12 - 54P. Raatikainen Switching Technology / 2003

Contents

• Static networks

• Wavelength Routed Networks (WRN)

• Linear Lightwave Networks (LLN)

• Logically Routed Networks (LRN)

 – Virtual connections: an ATM example

Page 333: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 333/369

12 - 55P. Raatikainen Switching Technology / 2003

Virtual connections - an ATM example

• Recall the problem of providing full connectivity among five locations

 – suppose each location contains a number of end systems thataccess the network through an ATM switch. The interconnectedswitches form a transport network of 5*4 = 20 VPs.

• The following five designs are now examined and compared:

 – Stand-alone ATM star 

 – Stand-alone ATM bi-directional ring

 – ATM over a network of SONET cross-connects

 – ATM over a WRN

 – ATM over a LLN

• Traffic demand: each VP requires 600 Mbits/s (≈ STM-4/STS-12)

• Optical resources: λ-channels and transceivers run at the rate of

2.4 Gbits/s (≈ STM-16/STS-48)

12 - 56P. Raatikainen Switching Technology / 2003

Stand-alone ATM networks

4

5

1

2

3

6

ATM switch/cross-connect with transceiver 

4

5

1

2

3

Page 334: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 334/369

12 - 57P. Raatikainen Switching Technology / 2003

Embedded ATM networks

A1

A2 A

3

A5

A4

   A      A

    A  A    

S

S

S

4

S

51

S

2

S

3

6

A

A ATM switch SDH/SONET DCSS ONN

DCS network Optical network Shared medium

S

4

5

1

2

6

S

A

S   

A   

    S

   A

3   S

   A     S

     A

12 - 58P. Raatikainen Switching Technology / 2003

Case 1 - Stand-alone ATM star 

• Fiber links are connected directly to ports on ATM switches, creating a point-to-point optical connection for each fiber

 – each link carries 4 VPs in each direction⇒ each optical connection needs 2.4

Gbits/s, which can be accomodated using a single λ-channel

 – one optical transceiver is needed to terminate each end of a link, for a total of 10

transceivers in the network

• Processing load is unequal:

 – end nodes process their own 8 VPs carrying 4.8 Gbits/s

 – center node 6 processes all 20 VPs carrying 12.0 Gbits/s⇒ bottleneck

• Inefficient utilization of fibers, since

 – even though only one λ-channel is used, the total bandwidth of each fiber is

dedicated to this system

• Poor survivability, since

 – if any link is cut, network is cut in two

 – if node 6 fails, the network is completely distroyed

Page 335: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 335/369

12 - 59P. Raatikainen Switching Technology / 2003

Case 2 - Stand-alone ATM bi-directionalring

• Fiber links are connected directly to ports on ATM switches, creating a point-to-point optical connection for each fiber

 – assuming shortest path routing, each link carries 3 VPs in each direction⇒ each optical connection needs 1.8 Gbits/s, which can beaccommodated using a single λ-channel (leaving 25% spare capacity)

 – 1 optical transceiver is needed to terminate each end of a link, for a totalof 10 transceivers in the network

• Equal processing load:

 – each ATM node processes its own 8 VPs and 2 additional transit VPscarrying an aggregate traffic of 6.0 Gbits/s

• Thus,

 – no processing bottleneck

 – the same problem with optical spectrum allocation as in case 1

 – but better survivability, since network can recover from any single link cutor node failure by rerouting the traffic

12 - 60P. Raatikainen Switching Technology / 2003

Case 3 - ATM embedded in DCS network

• ATM end nodes access DCSs through 4 electronic ports

• Fiber links are now connected to ports on DCSs, creating a point-to-point

optical connection for each fiber

 – each link carries 4 VPs in each direction => each optical connectionneeds 2.4 Gbits/s, which can be accommodated using a single λ-channel

 – again, 1 optical transceiver is needed to terminate each end of a link• Processing load is lighter

 – ATM nodes process their own 8 VPs carrying 4.8 Gbits/s

 – but it is much simpler to perform VP cross-connect functions at the STM-4/STS-12 level than at the ATM cell level (as was done in case 1)

 – a trade-off must be found between optical spectrum utilization and costs

 – the more λ-channels on each fiber (to carry “background” traffic), themore (expensive) transceivers are needed

• Survivability and reconfigurability are good

 – since alternate paths and additional bandwidth exist in the DCS network

Page 336: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 336/369

12 - 61P. Raatikainen Switching Technology / 2003

Case 4 - ATM embedded in a WRN

• DCSs are now replaced by optical nodes containing WSXCs

• Each ATM end node is connected electronically to a NAS

• Each VP in the virtual topology must be supported by

 – a point-to-point optical connection occupying one λ-channel

 – thus, 4 tranceivers are needed in each NAS (and totally 20 transceivers)

 – however, no tranceivers are needed in the network nodes

• With an optimal routing and wavelength assignment,

 – the 20 VPs can be carried using 4 wavelengths (= 800 GHz)

• Processing load is very light

 – due to optical switching (without optoelectronic conversion at each node)

 – Note: ATM nodes still process their own 8 VPs carrying 4.8 Gbits/s

• As in case 3, survivability and reconfigurability are good

 – since alternate paths and additional bandwidth exist in the underlyingWRN

12 - 62P. Raatikainen Switching Technology / 2003

Case 5 - ATM embedded in an LLN

• WSXCs are now replaced by LDCs

• A single waveband is assigned to the ATM network, and the LDCs are set to

create an embedded tree (MPS) on that waveband

 – the 20 VPs are supported by a single hyperedge in the logical topology

 – since each λ-channel can carry 4 VPs, 5 λ-channels are needed totally,all in the same waveband (= 200 GHz)

 – only 1 transceiver is needed in each NAS (and totally 5 transceivers)using TDM/T-WDMA in FT-TR mode

• Processing load is again very light

 – due to optical switching (without optoelectronic conversion at each node)

 – Note: ATM nodes still process their own 8 VPs carrying 4.8 Gbits/s

• As in cases 3 and 4, survivability and reconfigurability are good

 – since alternate paths and additional bandwidth exist in the underlying LLN

Page 337: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 337/369

12 - 63P. Raatikainen Switching Technology / 2003

Comparison of ATM network realizations

Case

Opticalspectrum

usage

Number of optical

transceivers

Nodeprocessing

load Others

1234

5

Very highVery highLowestMedium

Low

10101020

5

Very highHighMediumVery low

Very low

Poor survivability-High DCS-

Rapid tunabilityrequired, opticalmulti-cast possible

Page 338: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 338/3691

13 - 1P. Raatikainen Switching Technology / 2003

Optical switches

Switching TechnologyS38.165

http://www.netlab.hut.fi/opetus/s38165

13 - 2P. Raatikainen Switching Technology / 2003

Optical switches

• Components and enabling

technologies• Contention resolution

• Optical switching schemes

Page 339: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 339/3692 

13 - 3P. Raatikainen Switching Technology / 2003

Components and enabling technologies

• Optical fiber

• Light sources, optical transmitters

• Photodetectors, optical receivers

• Optical amplifiers

• Wavelength converters

• Optical multiplexers and demultiplexers

• Optical add-drop multiplexers

• Optical cross connects

• WDM systems

13 - 4P. Raatikainen Switching Technology / 2003

Optical fiber 

• Optical fiber is the most important transport medium for high-speed communications in fixed networks

• Pros

 – immune to electromagnetic interference

 – does not corrode – huge bandwidth (25 Tbit/s)

• Cons

 – connecting fibers requires special techniques (connectors,specialized personnel to splice and connect fibers)

 – does not allow tight bending

• An optical fiber consists of

 – ultrapure silica

 – mixed with dopants to adjust the refractive index

Page 340: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 340/3693 

13 - 5P. Raatikainen Switching Technology / 2003

Optical fiber (cont.)

• Optical cable consists of several layers

 – silica core

 – cladding, a layer of silica with a different mix of dopants

 – buffer coating, which absorbs mechanical stresses

 – coating is covered by a strong material such as Kevlar

 – outermost is a protective layer of plastic material

Plastic

Kevlar TM

Cladding

Buffer coating

Glassy core

Cross section (not to scale)

13 - 6P. Raatikainen Switching Technology / 2003

Optical fiber (cont.)

• Fiber cable consists of a bundle of optical fibers, up to 432 fibers.

• Refractive index profile of a fiber is carefully controlled duringmanufacturing phase

• Typical refractive index profiles

 – step index profile

 – graded index profile

Core fiber Cladding

Step indexprofile

n1

n2

n(x)

n2

x

Graded indexprofile

n1

n2

n(x)

n2

x   ∆

Page 341: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 341/3694 

13 - 7P. Raatikainen Switching Technology / 2003

Optical fiber (cont.)

• Light beams are confined in the fiber

- by total reflection at the core-cladding interface in step-index fibers

- by more gradual refraction in graded index fibers

n2

n1 Step index

Graded index

13 - 8P. Raatikainen Switching Technology / 2003

Optical fiber (cont.)

• Fiber can be designed to support

• several propagation modes => multimode fiber

• just a single propagation mode => single-mode fiber

Multimode fiber (many directional rays)

Core fiber 

ncore

Claddingnclad

d = 50 µm

D = 125 ± 2 µm

Single-mode fiber (one directional rays due to small d/D ratio)

Claddingnclad

d = 8.6 - 9.5 µm

D = 125 ± 2 µm

Page 342: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 342/3695 

13 - 9P. Raatikainen Switching Technology / 2003

Optical fiber (cont.)

• Multimode graded index fiber 

• small delay spread

• 1% index difference between core and cladding amounts to1-5 ns/km delay spread

• easy to splice and to couple light into it

• bit rate limited up to 100 Mbit/s for lengths up to 40 km

• fiber span without amplification is limited

• Single mode fiber 

• almost eliminates delay spread

• more difficult to splice and to exactly align two fibers together

• suitable for transmitting modulated signals at 40 Gbit/s or higherand up to 200 km without amplification

13 - 10P. Raatikainen Switching Technology / 2003

Optical fiber characteristics

• Dispersion is an undesirable phenomenon in optical fibers

• causes an initially narrow light pulse to spread out as itpropagates along the fiber

• There are different causes for dispersion

• modal dispersion

• chromatic dispersion

• Modal dispersion

• occurs in multimode fibers

• caused by different (lengths) propagation paths of different modes

• Chromatic dispersion

• material properties of fiber, such as dielectric constant andpropagation constant, depend on the frequency of the light

• each individual wavelength of a pulse travels at different speedand arrives at the end of the fiber at different time

Page 343: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 343/3696 

13 - 11P. Raatikainen Switching Technology / 2003

Optical fiber characteristics (cont.)

• Chromatic dispersion (cont.)

• dispersion is measured in ps/(nm*km), i.e. delay per wavelengthvariation and fiber length

• Dispersion depends on the wavelength

• at some wavelength dispersion may be zero

• in conventional single mode fiber this typically occurs at 1.3 µm- below, dispersion is negative, above it is positive

• For long-haul transmission, single mode fibers with specializedindex of refraction profiles have been manufactured

• dispersion-shifted fiber (DSF)

• zero-dispersion point is shifted to 1.55 µm

13 - 12P. Raatikainen Switching Technology / 2003

Optical fiber characteristics (cont.)

• Fiber attenuation is the most important transmission characteristic

• limits the maximum span a light signal can be transmittedwithout amplification

• Fiber attenuation is caused by light scattering on• fluctuations of the refractive index

• imperfections of the fiber

• impurities (metal ions and OH radicals have a particular effect)

• A conventional single-mode fiber has two low attenuation ranges

• one at about 1.3 µm

• another at about 1.55 µm

Page 344: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 344/3697 

13 - 13P. Raatikainen Switching Technology / 2003

Optical fiber characteristics (cont.)

• Between these ranges is a high attenuation range(1.35-1.45 µm), with a peak at 1.39 µm, due to OH radical

• special fibers almost free of OH radicals have beenmanufactured

• such fibers increase the usable bandwidth by 50%

• the whole range from 1.335 µm to 1.625 µm is usable, allowing

about 500 WDM channels at 100 GHz channel spacing

13 - 14P. Raatikainen Switching Technology / 2003

Optical fiber characteristics (cont.)

• The attenuation is measured in dB/km; typical values are

• 0.4 dB/km at 1.31 µm

• 0.2 dB/km at 1.55 µm

• for comparison, attenuation in ordinary clear glass is about 1dB/cm = 105 dB/km

Zero-dispersion line

λ (µm)

Absorption due to OH-

(peak at 1385 nm)Without OH-Transmitted

optical loss or attenuation (dB)

1.2 1.4 1.6

Page 345: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 345/3698 

13 - 15P. Raatikainen Switching Technology / 2003

Light sources and opticaltransmitters

• One of the key components in optical communications is themonochromatic (narrow band) light source

• Desirable properties

• compact, monochromatic, stable and long lasting

• Light source may be one of the following types:

• continuous wave (CW); emits at a constant power; needs anexternal modulator to carry information

• modulated light; no external modulator is necessary• Two most popular light sources are

• light emitting diode (LED)

• semiconductor laser

13 - 16P. Raatikainen Switching Technology / 2003

Light emitting diode (LED)

• LED is a monolithically integrated p-n semiconductor diode

• Emits light when voltage is applied across its two terminals

• In the active junction area, electrons in the conduction band andholes in the valence band are injected

• Recombination of the electron with holes releases energy in theform of light

• Can be used either as a CW light source or modulated light source(modulated by the injection current)

Terminal

P-type

Active junctionN-type

Terminal

Emittedlight

Page 346: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 346/369

Page 347: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 347/36910 

13 - 19P. Raatikainen Switching Technology / 2003

Semiconductor laser (cont.)

• Light fed back by mirrors is amplified by stimulatedemission

• Lasing is achieved above a threshold currentwhere the optical gain is sufficient toovercome losses (including thetransmitted light) from the cavity

p n+ -

i

Cleavedsurface

Cleavedsurface

13 - 20P. Raatikainen Switching Technology / 2003

Semiconductor laser (cont.)

• Cavity of a Fabry-Perot laser can support many modes of oscillation=> it is a multimode laser

• In single frequency operation, all but a single longitudinal mode mustbe suppressed - this can be achieved by different approaches:

• cleaved-coupled cavity (C3

) lasers• external cavity lasers

• distributed Bragg reflector (DBR)lasers

• distributed feedback (DFB) lasers

• The most common light sourcesfor high-bit rate, long-distance

• transmission are the DBR andDFB lasers.

Activelayer 

p p p n

Λ

Guidinglayer 

Activelayer 

Diffractiongratings

p p n

Page 348: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 348/36911

13 - 21P. Raatikainen Switching Technology / 2003

Semiconductor laser (cont.)

• Laser tunability is important for multiwavelength network applications

• Slow tunability (on ms time scale) is required for setting upconnections in wavelength or waveband routed networks

• achieved over a range of 1 nm via temperature control

• Rapid tunability (on ns-µs time scale) is required for TDM-WDMmultiple access applications

• achieved in DBR and DFB lasers by changing the refractiveindex, e.g. by changing the injected current in grating area

• Another approach to rapid tunability is to use multiwavelength laserarrays

• one or more lasers in the array can be activated at a time

13 - 22P. Raatikainen Switching Technology / 2003

Semiconductor laser (cont.)

• Lasers are modulated either directly or externally

• direct modulation by varying the injection current

• external modulation by an external device, e.g. Mach-Zehnder

interferometer

0

V

Light input Ii Modulated light Io

Mach-Zehnder interferometer

Page 349: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 349/36912 

13 - 23P. Raatikainen Switching Technology / 2003

Photodetectors and opticalreceivers

• A photodetector converts the optical signal to a photocurrent that isthen electronically amplified (front-end amplifier)

• In a direct detection receiver, only the intensity of the incoming signalis detected

• in contrast to coherent detection, where the phase of the opticalsignal is also relevant

• coherent systems are still in research phase

• Photodetectors used in optical transmission systems are

semiconductor photodiodes• Operation is essentially reverse of a semiconductor optical amplifier

• junction is reverse biased

• in absence of optical signal only a small minority carrier current isflowing (dark current)

13 - 24P. Raatikainen Switching Technology / 2003

Photodetectors and opticalreceivers (cont.)

• Operation is essentially reverse of a semiconductor optical amplifier(cont.)

• a photon impinging on surface of a device can be absorbed by an

electron in the valence band, transferring the electron to theconduction band

• each excited electron contributes to the photocurrent

• PIN photodiodes (p-type, intrinsic, n-type)

• An extra layer of intrinsic semiconductor material is sandwichedbetween the p and n regions

• Improves the responsivity of the device

• captures most of the light in the depletion region

Page 350: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 350/36913 

13 - 25P. Raatikainen Switching Technology / 2003

Photodetectors and opticalreceivers (cont.)

• Avalanche photodiodes (APD)

• In a photodiode, only one electron-hole pair is produced by anabsorbed photon

• This may not be sufficient when the optical power is very low

• The APD resembles a PIN

• an extra gain layer is inserted between the i (intrinsic) and nlayers

• a large voltage is applied across the gain layer• photoelectrons are accelerated to sufficient speeds

• produce additional electrons by collisions => avalanche effect

• largely improved responsivity

13 - 26P. Raatikainen Switching Technology / 2003

Optical amplifiers

• Optical signal propagating in a fiber suffers attenuation

• Optical power level of a signal must be periodically conditioned

• Optical amplifiers are key components in long haul optical systems

• An optical amplifier is characterized by• gain - ratio of output power to input power (in dB)

• gain efficiency - gain as a function of input power (dB/mW)

• gain bandwidth - range of frequencies over which the amplifieris effective

• gain saturation - maximum output power, beyond which noamplification is reached

• noise - undesired signal due to physical processes in theamplifier

Page 351: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 351/36914 

13 - 27P. Raatikainen Switching Technology / 2003

Optical amplifiers (cont.)

• Types of amplifiers

• Electro-optic regenerators

• Semiconductor optical amplifiers (SOA)

• Erbium-doped fiber amplifiers (EDFA)

13 - 28P. Raatikainen Switching Technology / 2003

Electro-optic regenerators

• Optical signal is

• received and transformed to an electronic signal

• amplified in electronic domain

• converted back to optical signal at the same wavelength

λ O/E Amp E/O   λ

Fiber Fiber  

Photonic domain

Optical receiver Optical transmitter 

Photonic domainElectronic domain

O/E - Optical to ElectronicE/O - Electronic to OpticalAmp - Amplifier

Page 352: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 352/36915 

13 - 29P. Raatikainen Switching Technology / 2003

Semiconductor optical amplifiers(SOA)

• Structure of SOA is similar to that of a semiconductor laser

• It consists of an active medium (p-n junction) in the form ofwaveguide - usually made of InGaAs or InGaAsP

• Energy is provided by injecting electric current over the junction

OA

Current pump

Weak input signal Amplified output signal

AR AR

Fiber Fiber 

13 - 30P. Raatikainen Switching Technology / 2003

Semiconductor optical amplifiers(cont.)

• SOAs are small, compact and can be integrated with othersemiconductor and optical components

• They have large bandwidth and relatively high gain (20 dB)• Saturation power in the range of 5-10 dBm

• SOAs are polarization dependent and thus require a polarization-maintaining fiber

• Because of nonlinear phenomena SOAs have a high noise figureand high cross-talk level

Page 353: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 353/36916 

13 - 31P. Raatikainen Switching Technology / 2003

Erbium-doped fiber amplifiers(EDFA)

• EDFA is a very attractive amplifier type in optical communications

systems

• EDFA is a fiber segment, a few meters long, heavily doped with

erbium (a rare earth metal)

• Energy is provided by a pump laser beam

EDFAWeak signal in

Fiber 

Amplified signal out

Isolator Isolator Fiber Fiber 

Pump(980 or 1480 nm at 3 W)

13 - 32P. Raatikainen Switching Technology / 2003

Erbium-doped fiber amplifiers(cont.)

• Amplification is achieved by quantum mechanical phenomenon of

stimulated emission

• erbium atoms are excited to a high energy level by pump laser signal

• they fall to a lower metastable (long-lived, 10 ms) state

• an arriving photon triggers (stimulates) a transition to the ground leveland another photon of the same wavelength is emitted

Excited erbium atoms at high energy level

Erbium atoms at low energy level

Longer wavelenghtsource (1480 nm)

Short- wavelenghtsource (980 nm)

 ~1 µs

Stimulated emission(1520 - 1620 nm)

Atoms at metastableenergy (~10 ms)

Page 354: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 354/36917 

13 - 33P. Raatikainen Switching Technology / 2003

Erbium-doped fiber amplifiers(cont.)

• EDFAs have a high pump power utilization (> 50 %).

• Directly and simultaneously amplify a wide wavelength band (> 80nm in the region 1550 nm) with a relatively flat gain

• Flatness of gain can be improved with gain-flattening optical filters

• Gain in excess of 50 dB

• Saturation power is as high as 37 dBm

• Low noise figure

• Transparent to optical modulation format

• Polarization independent

• Suitable for long-haul applications

• EDFAs are not small and cannot easily be integrated with othersemiconductor devices

13 - 34P. Raatikainen Switching Technology / 2003

Wavelength converters

Wavelength converters

• Enable optical channels to be relocated

• Achieved in optical domain by employing nonlinear phenomena

Types of wavelength converters

• Optoelectronic approach

• Optical gating - cross-gain modulation

• Four-wave mixing

Page 355: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 355/36918 

13 - 35P. Raatikainen Switching Technology / 2003

Wavelength converters -optoelectronic approach

• Simplest approach

• Input signal is

• received

• converted to electronic form

• regenerated

• transmitted using a laser at a different wavelength.

Receiver Regenerator Transmitter  

λs   λp

13 - 36P. Raatikainen Switching Technology / 2003

Optical gating -cross-gain modulation

• Makes use of the dependence of the gain of a SOA (semiconductoroptical amplifier) on its input power

• Gain saturation occurs when high opticalpower is injected

• carrier concentration is depleted

• gain is reduced

• Fast

• can handle 10 Gbit/s rates

SOA

Signal λsSignal λp

Filter  λp

Probe λp

Signal

Carrier density

Gain

Sprobeoutput

Time

Page 356: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 356/36919 

13 - 37P. Raatikainen Switching Technology / 2003

Four-wave mixing

• Four-wave mixing is usually an undesirable phenomenon in fibers

• Can be exploited to achieve wavelength conversion

• In four-wave mixing, three waves at frequencies f1, f2 and f3 producea wave at the frequency f1 + f2 - f3

• When

• f1 = fs (signal)

• f2 = f3 = fp (pump)

=> a new wave is produces at 2fp - fs• Four-wave mixing can be enhanced by using SOA to increase the

power levels

• Other wavelengths are filtered out

13 - 38P. Raatikainen Switching Technology / 2003

Four-wave mixing (cont.)

SOA Filter  f s f p

   2   f  s  -   f  p    f  s    f  p

   2   f  p  -   f  s 2f p- f s

2f p- f s

Page 357: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 357/36920 

13 - 39P. Raatikainen Switching Technology / 2003

Optical multiplexers anddemultiplexers

• An optical multiplexer receives many wavelengths from many fibers

and converges them into one beam that is coupled into a single fiber

• An optical demultiplexer receives a beam (consisting of multiple

optical frequencies) from a fiber and separates it into its frequency

components, which are directed to separate fibers (a fiber for each

frequency)

Optical multiplexer 

λ1

λ2

λN

...  λ1 ,λ2 , …,λN

Optical demultiplexer 

λ2

λN

...

λ1

λ1 ,λ2 , …,λN

13 - 40P. Raatikainen Switching Technology / 2003

Prisms and diffraction gratings

• Prisms and diffraction gratings can be used to achieve these functions

in either direction (reciprocity)

• in both of these devices a polychromatic parallel beam impinging

on the surface is separated into frequency components leaving the

device at different angles• based on different refraction (prism) or diffraction (diffraction

grating) of different wavelengths

Fibers

λ1+ λ2+ ...+λN

λ1

λ2

λN

...

Multiplexed beam

Lens

Fibers

λ1+ λ2+ ...+λN

λ1

λ2

λN

...Diffractiongrating

Lens

Diffractedwavelenghts

Incident beam

Page 358: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 358/36921

13 - 41P. Raatikainen Switching Technology / 2003

Prisms and diffraction gratings(cont.)

λ1+ λ2+ ...+λN

Multiplexed beam

Fiber Lens Prism Lens

λ 1

λ 2 

λ N 

λ 3 

 . . .

n2

n1

λ1+ λ2+ ...+λN

Multiplexed beam

λ 1

λ 2 

λ N 

λ 3 

 . . .

n2

n1

13 - 42P. Raatikainen Switching Technology / 2003

Arrayed waveguide grating (AWG)

• AWGs are integrated devices based on the principle of interferometry

• a multiplicity of wavelengths are coupled to an array of waveguideswith different lengths

• produces wavelength dependent phase shifts

• in the second cavity the phase difference of each wavelengthsinterferes in such a manner that each wavelength contributesmaximally at one of the output fibers

• Reported systems

• SiO2 AWG for 128 channels with 250 GHz channel spacing

• InP AWG for 64 channels with 50 GHz channel spacing

λ1+ λ2+ ...+λN

λ1

λN

   .   .   .

w1

wN

Array of waveguides

Array of fibersS  2    S  1

Page 359: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 359/36922 

13 - 43P. Raatikainen Switching Technology / 2003

Optical add-drop multiplexers(OADM)

• Optical multiplexers and demultiplexers are components designed forwavelength division (WDM) systems

• multiplexer combines several optical signals at differentwavelengths into a single fiber

• demultiplexer separates a multiplicity of wavelengths in a fiber anddirects them to many fibers

• The optical add-drop multiplexer

• selectively removes (drops) a wavelength from the multiplex

• then adds the same wavelength, but with different data

λ1, λ2, ... ,λN   λ1, λ2, ... ,λN

OADM

λ2, ... ,λN

λ1   λ1

13 - 44P. Raatikainen Switching Technology / 2003

Optical add-drop multiplexers (cont.)

• An OADM may be realized by doing full demultiplexing andmultiplexing of the wavelengths

• a demultiplexed wavelength path can be terminated and a new

one created

OA OAλ1, λ2, ... ,λN   λ1, λ2, ... ,λN

OADMλ1, λ2, ... ,λN-1

λN   λN

Page 360: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 360/36923 

13 - 45P. Raatikainen Switching Technology / 2003

Optical cross-connects

• Channel cross-connecting is a key function in communication systems

• Optical cross-connection may be accomplished by

• hybrid approach: converting optical signal to electronic domain, usingelectronic cross-connects, and converting signal back to optical domain

• all-optical switching: cross-connecting directly in the photonic domain

• Hybrid approach is currently more popular because the all-opticalswitching technology is not fully developed

• all optical NxN cross-connects are feasible for N = 2…32

• large cross-connects ( N∼

1000) are in experimental or planning phase• All-optical cross-connecting can be achieved by

• optical solid-state devices (couplers)

• electromechanical mirror-based free space optical switching devices

13 - 46P. Raatikainen Switching Technology / 2003

Solid-state cross-connects

• Based on semiconductor directional couplers

• Directional coupler can change optical property of the path

• polarization

• propagation constant

• absorption index• refraction

• Optical property may be changed by means of

• heat, light, mechanical pressure

• current injection, electric field

• Technology determines the switching speed, for instance

• LiNbO3 crystals: order of ns

• SiO2 crystals: order of ms

Signal in Signal “on”

Signal “off”

Propagation constantcontrol (voltage)

Lightguide

Page 361: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 361/369

Page 362: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 362/36925 

13 - 49P. Raatikainen Switching Technology / 2003

Optical cross connects

• MEMS technology is still complex and expensive.

• Many MEMS devices may be manufactured on the same wafer

• reduces cost per system

• Many mirrors can be integrated on the same chip

• arranged in an array

• experimental systems with 16x16=256 mirrors have been built

• each mirror may be independently tilted

• An all-optical space switch can be

constructed using mirror arrays

R.J. Bates, Optical switching and networking handbook , McGraw-Hill, 2001

13 - 50P. Raatikainen Switching Technology / 2003

Optical switches

• Components and enabling technologies

• Contention resolution• Optical switching schemes

Page 363: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 363/36926 

13 - 51P. Raatikainen Switching Technology / 2003

Contention resolution

• Contention occurs when two or more packets aredestined to same output at the same time instant

• In electronic switches, contention solved usually bystore-and-forward techniques

• In optical switches, contention resolved by

 – optical buffering (optical delay lines)

 – deflection routing

 – exploiting wavelength domain• scattered wavelength path (SCWP)

• shared wavelength path (SHWP)

13 - 52P. Raatikainen Switching Technology / 2003

Optical delay loop

mT

 . . .

 . . .

 . . .

 . . .

T

2T

In_1

In_2

In_n

Out_1

Out_2

Out_n

Page 364: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 364/36927 

13 - 53P. Raatikainen Switching Technology / 2003

Deflection routing

 .

 . .

 . . .

In_1

In_2

In_n

Out_1

Out_2

Out_n

Out_3

Out_4

In_3

In_4

13 - 54P. Raatikainen Switching Technology / 2003

Wavelength conversion

 . . .

 . . .

In_1In_2

In_n

Out_1Out_2

Out_n

Out_3

Out_4

In_3

In_4

λ1

λ1   λ2

λ3

Page 365: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 365/36928 

13 - 55P. Raatikainen Switching Technology / 2003

Optical switches

• Components and enabling technologies

• Contention resolution

• Optical switching schemes

13 - 56P. Raatikainen Switching Technology / 2003

Optical packet switching

• User data transmitted in optical packets

– packet length fixed or variable

• Packets switched in optical domain packet-by-packet

• No optical-to-electrical (and reverse) conversions foruser data

• Switching utilizes TDM and/or WDM

• Electronic switch control

• Different solutions suggested

– broadcast-and-select

– wavelength routing

– optical burst switching

Page 366: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 366/36929 

13 - 57P. Raatikainen Switching Technology / 2003

Optical packet switch

• packet delineation• packet alignment• header and payload separation• header information processing• header removal

• switching of packets frominputs to correct outputsin optical domain

• contention resolution

• header insertion• optical signalregeneration

Inputinterfaces

Switchfabric

Outputinterfaces

Switch

control

Header 

rewrite

Sync.

control

 . . .

 . . .

 . . .

 . . .

13 - 58P. Raatikainen Switching Technology / 2003

Broadcast-and-select

• Input ports support different wavelengths (e.g. onlyone wavelength/port)

• Data packets from all input ports combined andbroadcasted to all output ports

• Each output port selects dynamically wavelengths, i.e.packets, addressed to it

• Inherent support for multi-casting

• Requires that control unit has receivedrouting/connection information before packets arrive

Page 367: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 367/369

Page 368: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 368/36931

13 - 61P. Raatikainen Switching Technology / 2003

Wavelength routing

In_1

 . . .

TWC

 . . .

 . . .

1

k

Out_1

Out_n

Contention resolution and buffering Wavelength switching

In_n TWC

1

k

 . . .

 . .

 . .

TWC

TWC

TWC - Tunable Wavelength Converter 

13 - 62P. Raatikainen Switching Technology / 2003

Optical burst switching

• Data transmitted in bursts of packets

• Control packet precedes transmission of a burst and is

used to reserve network resources– no acknowledgment, e.g. TAG (Tell-and-Go)

– acknowledgment, e.g. TAW (Tell-and-Wait)

• High bandwidth utilization (lower avg. processing andsynchronization overhead than in pure packetswitching)

• QoS and multicasting enabled

Page 369: optical switching comprehensive guide

8/13/2019 optical switching comprehensive guide

http://slidepdf.com/reader/full/optical-switching-comprehensive-guide 369/369

13 - 63P. Raatikainen Switching Technology / 2003

Header and packet formats

• In electronic networks, packet headers transmittedserially with the payload (at the same bit rate)

• In optical networks, bandwidth is much larger andelectronic header inspection cannot be done at wirespeed

• Header cannot be transmitted serially with the payload

• Different approaches for optical packet format

 – packets switched with sub-carrier multiplexed headers – header and payload transmitted in different λ-channels

 – header transmitted ahead of payload in the same λ-channel

 – tag (λ) switching - a short fixed length label containing routing

information

Fiber 

λ1

λ2

Payload

Header  Sub-carrier 

Header and packet formats (cont.)

Packets with sub-carrierheaders

Fiber 

λ1

λ2Header 

PayloadHeader and payload indifferent λ-channels

Header transmittedahead of payload inthe same λ-channel

Fiber 

λ1

λ2

Payload Header  