38

OMRON GUIA RÁPIDA SERIES NV3 PT

Embed Size (px)

Citation preview

Page 1: OMRON GUIA RÁPIDA SERIES NV3 PT
Page 2: OMRON GUIA RÁPIDA SERIES NV3 PT

Advanced U

sageA

dvanced Usage

Connecting w

ith C

PI PLCC

onnecting with

CPI PLC

Designing Screens

Designing Screens

PreparationPreparation

NVNV--series PTseries PTSimple Operation Simple Operation HandbookHandbook- A case of connection to a CP1 PLC -

Table of Contents

PreparationPreparationRequired devices ・・・・・・・・・・・・・・・ 2Wiring and Connection・・・・・・・・・・・ 4Turning on the power・・・・・・・・・・・・・・ 6Displaying the NV System Menu・・・ 7Setting the CP1 serial port --------- 8

Designing ScreensDesigning ScreensCreating new screen data・・・・・・・・ 12Setting the NV communications・・ 15Creating switch objects・・・・・・・・・・ 16Creating lamp objects・・・・・・・・・・・・ 19Creating data objects・・・・・・・・・・・・ 21Creating keyboard screens・・・・・・・ 23Creating texts or character stings ・ 26

Connecting with CP1 PLCConnecting with CP1 PLCTransferring screen data・・・・・・・・・ 28Testing the screen operations ------ 31

Advanced UsageAdvanced UsageSwitching screen displayfrom CP1 --------------------------------- 32Changing backlight colors from CP1 -------------------------------- 34Connecting PC and PLC via NV・・ 35

Page 3: OMRON GUIA RÁPIDA SERIES NV3 PT

2

Required DevicesRequired DevicesThese are the equipment and devices required to connect an NV-series PT to a CP1 PLC.

- RS-232C type (5 VDC) -XW2Z-200T-4 (2m,with a 5-V wire)

- RS-232C type (24 VDC) -XW2Z-200T-3 (2m,without a 5-V wire)XW2Z-500T-3 (5m,without a 5-V wire)

- RS-422A type (24 VDC ) -Prepare one by referring to the Manual.

- RS-232C type (24 VDC) -NV3Q-MR21 NV3Q-SW21

- RS-422A type (24 VDC) -NV3Q-MR41 NV3Q-SW41

■ For a NV3W (24 VDC type) or a NV3Q,use a 24-VDC power supply unit for it.

PT: NV-series

NV-PLC connection cablePLC: CP1-series

Compact horizontally long type: NV3W

- RS-232C type (5 VDC) -NV3W-MR20L NV3W-MG20L

- RS-232C type (24 VDC) -NV3W-MR20 NV3W-MG20

- RS-422A type (24 VDC) -NV3W-MR40 NV3W-MG40

QVGA type: NV3Q

※The NV3W of RS-232C type (5 VDC) does not need a power supply unit. The 5-V power is supplied from PLC through the XW2Z-200T-4 Special Cable.

Packaged PLC: CP1

Tricolor backlightof white, pink and read

STN color (4096 colors)Tricolor backlightof green, orange and read

Tricolor backlightof white, pink and read

Page 4: OMRON GUIA RÁPIDA SERIES NV3 PT

3

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

FA Integrated Tool Package

•CX-One Lite Ver.4CX-One Lite is a packaged software. It contains only the required tools for micro PLC application, which are selected from the CX-One.

•CX-One Ver.3.2CX-One is the integrated tool package. It contains the peripheral support software for OMRON PLC and components.

◆ Selective from the two in below.Included in both packages of CX-One Lite Ver.4 and CX-One Ver.3.2.※It cannot be purchased individually.•NV-Designer Ver.1

Screen designing software for NV

Programming software for PLC

-CX-Programmer jr. Ver.9Included in a package of CX-One Lite Ver.4.It can be purchased individually.- CX-Programmer Ver.8.21Included in a package of CX-One Ver.3.2.It can be purchased individually.

◆Selective from these:

NV-PC connection cable

NV3W

NV3W

NV3Q

PC•Use a commercially available USB cable.

CP1 PLC-PC connection cable

◆ Use the Special Cable (NV-TOL-3N) to connect the NV3W to a PC. When the PC does not have a RS-232C serial port, use a USB-serial conversion cable (CS1W-CIF31) as well.

◆ Use a commercially available USB cable to connect the NV3Q to a PC.

B connector maleA connector male

CP1

Connecting an NV3W to USB port on PC

•NV-TOL-3M + CS1W-CIF31

•NV-TOL-3M

Connecting an NV3Q

•Use a commercially available USB cable.

B connector male

A connector male

※Prepare at least one USB cable. It can be used to connect the NV to the CP1 PLC or to the PC alternatively.

PreparationPreparation

Connecting an NV3W toRS-232C serial port on PC

Page 5: OMRON GUIA RÁPIDA SERIES NV3 PT

4

Wiring and ConnectionWiring and ConnectionConnect the devices.※ This section explains the procedure to connect an NV3W (5-VDC type) PT to a CP1 PLC.

Example

CS1W-CIF31 + NV-TOL-3M

Commercially available USB cable(A connector male – B connector male)

XW2Z-200T-4(2m, with 5-V wires)

Connecting the NV and CP1

Connecting an NV3W (5-VDC type) PT to the USB port on PC

5V power (green)

Name (color)

RD (orange)SD (blue)

SG (pink)

NV3W (5-VDC)

※The NV3W of 5-VDC type does not need a power supply unit. The 5-V power is supplied from PLC through the XW2Z-200T-4 Special Cable.

NV3W –MR20L

PC

CP1

Wiring for CP1 AC power supply

Wire for the CP1 AC power supply.

Connect the NV and the CP1 with the XW2Z-200T-4 Special Cable.

FG (black)

Ground to 100 ohm or less

XW2Z-200T-4Special Cable

(2m,with 5-V wires)

Upper terminal block

100 to 240 VAC, 50/60Hz

Page 6: OMRON GUIA RÁPIDA SERIES NV3 PT

5

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

The NV3W PT can be mounted vertically.The side having the serial port and the power supply connector must face up.

■ When the NV3W is used vertically:

■ When the CP1 uses a 24-VDC power supply,

Wire the 24-VDC power supply as shown below.

・XW2Z-200T-3(2m, without 5-V wire)・XW2Z-500T-3(5m,without 5-V wire)

■ When the NV3W (24-VDC type) or the NV3Q is connected by RS-232C type cable, wire the NV and the PLC as follows:

The power is supplied from the external supply unit to PT.Name (color)

RD (orange)SD (blue)

SG (pink)

NV3W (24-VDC) or NV3Q

FG (black)

Ground to 100 ohm or less

24-VDC power supply

Upper terminal block

24-VDC power supply PreparationPreparation

Page 7: OMRON GUIA RÁPIDA SERIES NV3 PT

6

Turning on the PowerTurning on the PowerTurn on the power to the CP1. The power is also supplied to NV through the RS-232C serial port on the CP1.

If you turn on the power to NV after you change the DIP switch pins on the NV back face to any setting other than the factory setting, the NV starts up in a special operation mode. You can use the functions to prohibit accessing the System Menu and to clear the F-ROM. Do not use the NV in any settings other than shown below.

Normal operation (factory setting)

Prohibiting accessing System Menu Clearing F-ROM

※ The data saved in the F-ROM includes screen data and NV configuration data.※ Other than the DIP switch setting, you can clear the F-ROM from the System Menu.

Turning on the power to CP1

■ NV startup mode

Turn on the power to the CP1. The POWER LED indicator on the front of CP1 lights in green. The NV screen shows a message as follows:

※ The message “No Screen data” is shown when the NV has no screen data. As the NV contains no data at factory shipping, the message is shown accordingly.

All pins off Turn on Pin 2 Turn on Pin 2, 3 and 4

POWERLED

XW2Z-200T-4

Page 8: OMRON GUIA RÁPIDA SERIES NV3 PT

7

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Displaying the NV System MenuDisplaying the NV System MenuThe System Menu is the special screen that is used to configure the NV. Some settings such as touch switch adjustment can only be done on the System Menu.

Accessing the System Menu

Follow the steps below to access the System Menu.

1. Touch by hand on the touch panel. (This is common for entire NV-series.)

① Touch part A at top left for 2 seconds or longer.

② Immediately after that, tough part B at top right and then part C at bottom right.

※ Be sure to touch part A, B and C one by one in this order. Do not press them at the same time.

2. The startup screen of the System Menu will show.

The startup screen of the System Menu will show. Touching the Setting key or the Test key will show the next screen. Touching the ESC key will end the System Menu and return to normal operation.

※ The “System Ver” indicates the NV system ROM version.

When the NV has no screen data, the System Menu is shown in English.The System Menu screens differ by PT models. This explanation uses the NV3W.

■ To show the System Menu in other languages:・On the NV3W, the language changes to the one set by System Language (either English

or Japanese) option for the transferred screen data. Thus transferring the screen data enables the language setting. ※The language is not switchable on the NV System Menu.

・On the NV3Q , the language is switchable between English and Japanese on the NV System Menu.

Touch part A for 2 seconds or longer. Then tough part B and C in this order.

PreparationPreparation

Page 9: OMRON GUIA RÁPIDA SERIES NV3 PT

8

Setting the CP1 Serial Port Setting the CP1 Serial Port To have the NV and the CP1 communications, the both serial ports must have the same setting. Use the PLC programming tool or CX-Programmer to set the communications standard on the CP1.

■ Be sure to change the Stop Bit on the PLC from the default 2 to 1.The stop bit for the NV serial communications is fixed to 1 . Therefore, the stop bit of the PLC serial port must be changed from the default 2 to 1.

NV-CP1 communications setting exampleBoth the NV and the CP1 support the high speed communication of 115,200 bps. Connect them in this baud rate.Set the RS-232C serial ports on both of the NV and the CP1 as follows:

・Mode: Host Link・Baud rate: 115,200 bps・Data length: 7・Stop bit: 1・Parity bit: even

Communications setting for RS-232C serial port built in the CP1

Use the PLC programming tool or the CX-Programmer. Follow the steps below to set the RS-232C serial port built in the CP1.

Connect the CX-Programmer and the CP1 online by a USB cable.

Change the CP1 operation mode to “Programming” (※Stop).

Upload the PLC system setting (including the built-in RS-232C serial

port setting) from CP1.

Set the built-in RS-232C serial port on the PLC system setting.

Write the PLC system setting (including the built-in RS-232C serial port setting)

into the CP1.

Turn on the power to the CP1.(The setting is reflect only after a

power-on subsequent to the setting.)

11

22

33

44

55

66

※ Communications may be enabled, even when the stop bit on the PLC is 2 while the bit on the NV is 1. However, be sure to align the both in 1.

Page 10: OMRON GUIA RÁPIDA SERIES NV3 PT

9

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Online connection of CX-Programmer and CP1

1. Start up the CX-Programmer. On the Windows Start menu, select Program - OMRON –CX-One - CX-Programmer - CX-Programmer.

2. On the menu bar, select PLC - Auto Online – Direct Online.

3. In the Direct Online dialog box, select the USB Connection for the PC – PLC (CP1) connection type. Click the Connect Button.

Connection Type:Select either the Serial Connection or the USB Connection.

① Click the No button.※ Click the Yes button to upload

the program to the PC.

4. When the PC is connected with the CP1, a new project will start.

PreparationPreparation

Page 11: OMRON GUIA RÁPIDA SERIES NV3 PT

10

Changing the CP1 operation mode into Program

1. On the menu bar, select the PLC – Operation Mode – Program.

① Confirm that stopping the ladder program do not cause any problem. Click the Yes button.

2. The CP1 operation mode changes to the Program.

The “Stopped” sign shows.

The “Program Mode” sign shows.

Transferring, setting and writing the PLC system setting

1. Double-click the Settings in the project tree.

Double-click!!

Page 12: OMRON GUIA RÁPIDA SERIES NV3 PT

11

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

3. On the menu bar, select the Option – Transfer [ to PLC ].

Click!!

※ It is not selectable, when the PLC operation mode is not in Program.

① Do not check.

② Click the Yes button.

2. The PLC System Setting menu shows. On the menu, select the Option – Transfer [from PLC ].

※The second value from the left of parameter is the stop bit. Be sure to set it to “1”when the PLC is connected to an NV.

Click!!

Click!!

2. The PLC setting for the CP1 is uploaded. to the PC. Make the setting on the built-in RS-232C Port tab as follows.

Turning on the CP1 power.

1. Turn on the CP1 power. The RS-232C serial port setting becomes effective when the power is turned on. This completes the CP1 communications setting.

PreparationPreparation

Page 13: OMRON GUIA RÁPIDA SERIES NV3 PT

12

Creating New Screen DataCreating New Screen DataThe NV communications setting is achieved by transferring the screen data to the NV.Create a screen data by using the screen designing software, NV-Designer.

Starting up the NV-Designer and creating new projects

1. On the Windows Start menu, select Program – OMRON – CX-One – NV-Designer -NV-Designer.

3. On the Select Model dialog Box, select the NV Model and the NV Type. Enter a project name in the File Name field. Click the Next button.

NV Model:Select the model of NV.

2. After the NV-Designer starts up, the NV-Designer dialog box will show. Select the Create New Project option button. Click the OK button.

NV Type:Select one from monochrome, color and vertical.File Name:Enter a project file name. In the left example, a file “test.nvp” and a folder “test” are created.

Page 14: OMRON GUIA RÁPIDA SERIES NV3 PT

13

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

4. Select the PLC Model to connect. Click the Next button.

PLC Model:Select the PLC model to connect.

5. In the System Memory Area field, set the Word Area and the Bit Area. Click the Next button.

As the Word Area, the areas of 3 words in series are occupied to read and write the data in units of words such as Screen No. As the Bit Area, the areas of 3 words in series are occupied to read and write the data in units of bits such as Backlight Light/Blink. In total 6 words are occupied.

the area used for the PLC to control the basic operations such as switching screens.The PLC area is steadily occupied and has constant communications.

■ System memory is:

■Number of words occupied as the system memory

System Memory Area:Set the areas occupied and used for PLC to control the NV.

※The default address allocated to the bit area is “0”. As it corresponds to the CP1 input area, it must be changed to a program area such as Work Area.

Designing Screens

Designing Screens

※ The address allocated to the system memory can be changed from the menu bar. Select PT – NV Configuration.

Page 15: OMRON GUIA RÁPIDA SERIES NV3 PT

14

4. The Main Window of NV-Designer will show.In the Screen Manager, double-click the No. “0”. Then the Base Screen 0 and the Object Library will show.

You can place texts and objects on this screen, and create a new screen.

Manu bar

Tool bar

Graphic bar

Base Screen 0 Object LibraryScreen Manager

Base Screen

Object LibraryThis is the collection of objects such as switch, lamp, data display and keyboard.You can also create an original object library, or customize it by registering only selected objects.

Screen Manager

This is used to manage the screens by their number. You can create a new base screen, and edit, copy, move and delete it. You can also open plural projects at the same time and copy and move a screen among the projects.

Double-click!!

Page 16: OMRON GUIA RÁPIDA SERIES NV3 PT

15

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Setting the NV CommunicationsSetting the NV CommunicationsSet the NV - CP1 communications as the screen data.

Setting the NV communications1. On the NV-Designer menu, select PT – NV Configuration.

Click!!

NV-CP1 communications setting exampleThe CP1 communications was set as follows: Set the same for the NV communications.

・Mode: Host Link・Baud rate: 115,200 bps・Data length: 7・Stop bit: 1・Parity bit: even

■ The stop bit for the NV serial communications is fixed to 1.Therefore, the stop bit of the PLC serial port must be changed from the default 2 to 1.

2. Select the Communication Parameter tab. Set the communications with the CP1.Click the OK button. Close the Dialog box. This completes the NV communication setting.

Click!!

Set these items for communications with CP1.

Designing Screens

Designing Screens

Page 17: OMRON GUIA RÁPIDA SERIES NV3 PT

16

Creating Switch ObjectsCreating Switch ObjectsThis and following few pages describe creating object on the screen, and confirming the NV-CP1 operations. First is the switch object that turns on and off the bit address in the PLC.

An example of switch objectThis switch object turns on the bit 10.00 on the PLC when you press the switch, and turns off the bit 10.00 when you release it. (Momentary operation)

Normally it is OFF. While pressed it turns to ON.

Choosing a switch objectSelect a switch object from the library. Drag and drop it at any desired space on the base screen.

① Use the object library Standard (NV3W).

② Use an object SW2.

Drag and drop!!

When pressed When released

Page 18: OMRON GUIA RÁPIDA SERIES NV3 PT

17

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Setting the function for the switch objectDouble-click the switch object. Select the Basic Setup tab. Set the operation mode and the on-off indication of lamp in each field.

Operation Mode:It specifies the operation and the bit address in the PLC.

ON/OFF Indication (Lamp):Select either On to switch the ON/OFF indication or Off not to switch it. When you select On, set also the switch timing.

Creating the switch label1. Select the Label tab. Click the When OFF button to set the label when the switch is off.

When ON / When OFF:Set the label each when the

switch is on and off.※ Start with the When OFFbutton.

Text:Enter a text or string to show.

Font and Position: Set the front type and the position to show the text or string.

Size:Set the front size of the text or string.

Color:Set the text color and the background color.

Designing Screens

Designing Screens

Page 19: OMRON GUIA RÁPIDA SERIES NV3 PT

18

2. Click the When ON button. Click the COPY from OFF button. Then the setting When OFF is copied to When ON. The two have the same setting.

① Select the When ON.

② Click the COPY from OFF button.

Click!!

3. Change the character color When ON into white.After setting, click the OK button and close the setting dialog box. This completes creating a switch object.

① Change the character color into white.

Confirming the object on/off state by previewSelect the object. On the tool bar, select the Object State. You can preview the on/off state of the selected object.

Object stateOFF (Normal) ON (When pressed)

① Select an object.(You can select plural objects.)

② Switch the on/off state by Object state.

Page 20: OMRON GUIA RÁPIDA SERIES NV3 PT

19

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Creating Lamp ObjectsCreating Lamp ObjectsThe lamp objects switch colors in accordance with the on/off state of the corresponding bit address on the PLC.

An example of lamp object

The lamp changes color in accordance with the on/off state of bit 10.00 on the PLC.

The lamp indicates white when the bit 10.00 is off. It indicates black when the bit 10.00 is on.

Bit OFF Bit ON

Choosing a lamp objectFrom the Object Library, select a lamp object. Drag and drop it at any desired space on the base screen.

① Use the object library Standard (NV3W).

② Use the object Lamp0.

Drag and drop!!

Designing Screens

Designing Screens

Page 21: OMRON GUIA RÁPIDA SERIES NV3 PT

20

Setting the function for the lamp objectDouble-click the lamp object. Select the Basic Setup tab. Set the bit address in the ON/OFF Bitfield. Click the OK button and close the dialog box. This completes creation of lamp object.

ON /OFF Bit: Set the bit address of the PLC.

Page 22: OMRON GUIA RÁPIDA SERIES NV3 PT

21

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Creating Data ObjectsCreating Data ObjectsA data object indicates a PLC address in a numeric value or a character string. Data objects are used for indication only (no entries allowed) or for changing the values from the Keyboard Screen as well.

An example of data objectThis data object indicates the PLC address of D100 in a decimal number.Clicking the object changes the screen to the Keyboard. Enter a value on the keyboard and change the value for the D100 address.

Choosing a data object

From the Object Library, select a data object. Drag and drop it at any desired space on the base screen.

① Use the object library Standard (NV3W).

② Use the object Data.Drag and drop!!

It changes to the Keyboard Screen. Enter a numeric valueClick the object

Designing Screens

Designing Screens

Page 23: OMRON GUIA RÁPIDA SERIES NV3 PT

22

Setting the function for the data objectDouble-click the data object. Select the Basic Setup tab. ※This example uses the default setting.

Address:Set the PLC word address.

Data to Display: Set the Number of Digits, the

Data Format and the Zero Suppression.

※Select “ASCII” for the format when the data is indicated or entered as a character string.

Setting to enable or disable the inputs and other setting itemsClick the Input tab. Select the option button On. Set the input method in other fields. Click the OK button. Close the setting dialog box. This completes the data object setting.

Supported Keyboard:Set the input method to the keyboard.・Keyboard Screen:

Input after switching to the Keyboard Screen.

・Keyboard Object:Input from the keyboard object that is on the same screen as the data object.

Input:Select either On to enter values from the screen or Off not to do it.※ When the Off is selected, the screen is for indication only (no entries allowed).

Startup Condition:Select the value input timing. ・Conditions

When the specified bit address satisfies the conditions, the data object enables inputs.

91

Page 24: OMRON GUIA RÁPIDA SERIES NV3 PT

23

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Creating Keyboard ScreensCreating Keyboard ScreensA Keyboard Screen must be created when a keyboard is selected asthe method to input data objects.

Creating a Keyboard Screen1. On the menu bar, select File – Keyboard Screen.

Click!!

2. On the Edit Keyboard Screen dialog box, select the screen No.0. Click the Draw button. Then the Keyboard Screen No.0 opens.

Click!!

An example of keyboard screen

On this Keyboard Screen, you can enter decimal values and signs. Also you can confirm the values entered from the keyboard before they are finalized.

Designing Screens

Designing Screens

Page 25: OMRON GUIA RÁPIDA SERIES NV3 PT

24

Choosing a keyboard object.From the Object Library, select a keyboard object. Drag and drop it at any desired space on the keyboard screen.

① Use the object library Standard (NV3W).

③ Use the object DEC Sign1.

Drag and drop!!

② Use the object groupKeyboard.

※ A window opens for each object type.

Setting the function for the keyboard objectDouble-click the keyboard object. Select the Basic Setup tab. Make a necessary setting as shown below. ※This example uses the default setting. Click the OK button and close the setting dialog box.

Image: The setting can be confirmed here.Clicking a key object will show the key setting dialog box. Enter a value on the box. You can set a value for each key.

Number of keys:Set the vertical (line) and horizontal (row) number of keys.

Keyboard Replacement:Keyboard keys are selective among upper case, lower case and alphanumerical & symbols. When the keyboard replacement (On) is selected, set the number of keyboard screens.

Click!!

Page 26: OMRON GUIA RÁPIDA SERIES NV3 PT

25

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Choosing a data objectChoose and place a data object to show the value entered in the screen.From the Object Library, select a data object. Drag and drop it at any desired space on the keyboard screen.

① Use the object library Standard (NV3W).

③ Use the object Data.

Drag and drop!!

② Use the object groupData.

Setting the function for the data objectSet the function for the data object. ※This example uses the default setting. Click the OK button and close the setting dialog box. This completes creating a keyboard screen.

Data to Display:Set the digit number to display.

Designing Screens

Designing Screens

Page 27: OMRON GUIA RÁPIDA SERIES NV3 PT

26

Creating Texts (or Character Strings)Creating Texts (or Character Strings)This section explains the procedures to show texts or character strings on a screen. It also describes how to change the character attributes such as font, size and color. This way, the character string will stand out.

An example of text or character string

In this example, the character string “Value” is outlined.

Creating a text or a character string1. On the graphic bar, click the

Character String icon.2. On the base screen, click a position

to show a character string.

3. Enter a string. 4. On the graphic bar, click the Character Type icon.

5. The Character Attributes dialog box will show. Check the box for Outlined. Click the OK button and close the setting dialog box. This completes creating a character string.

Click!!NEXT

NEXT

Page 28: OMRON GUIA RÁPIDA SERIES NV3 PT

27

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

■ To show a picture image such as bitmap on the NV screen:

The NV-series PTs support display of picture images such as bitmap images.You can transfer to and paste the images on the NV by copying them on the Windows clip board.

1. On the workspace of graphic software such as MS Paint, open an image file to show on the NV.

2. Select the range of the image to show on the NV. Copy it.

<MS Paint>① Select the range.

(Press Ctrl + A for select all)② Right-click the image, and

select Copy from the context menu. Alternatively, pressCtrl + C and copy the image on the clip board.

3. On the NV-Designer, open the screen to paste the image. Right-click and select Past from the context menu. Alternatively, press Ctrl + V to past the image.

Right-Click!! ① Select Past.

※ Any images or pictures larger than the display resolution (for NV3W, 128 w x 64 h, and for NV3Q, 320 w x 240 h) cannot be pasted. Scale down the images to any sizes smaller than the resolution, before you past them.

Right-click!!

Designing Screens

Designing Screens

Page 29: OMRON GUIA RÁPIDA SERIES NV3 PT

28

Transferring Screen DataTransferring Screen DataTransfer the created screen data to the NV.

Setting the transfer method

1. On the menu bar, select PT – Transfer – Transfer.

Click!!

2. On the Data Transfer dialog box, set the communications with the PT as follows:Select the option button RS-232C serial in the Communication Method field. Click the Communications Setting button. On the Communication Parameters dialog box, select the PC COM port No. in the Port Number for RS-232C serial. Click the OK button and close the Communication Parameters dialog box.

Click!!② Click Communication

Setting button.

① Communication Method:Select RS-232C serial. ※ Select also RS-232C

serial when the CS1W-CIF31 and the RS-232C / USB conversion are used.

■ When you use a NV3Q PT,Select the option button USB as the communication method.

③ Set the PC COM port No. in the Port Number field.

※ The COM port No. can be confirmed by the device manager.

Page 30: OMRON GUIA RÁPIDA SERIES NV3 PT

29

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Transferring the screen data1. Set the transfer direction, the data to transfer. Then transfer the data to the NV.

① Direction:Select the option button forNV-Designer -> NV.

② Data to Transfer:Check the box for All Data.

③ Click the OK button to start transferring. The Transfer Data dialog box closes.

Click!!

■ Shortcut Ctrl + TTransfer is a frequently used operation. Use the shortcut for your convenience.

Transfer Data After Clear NV Screen:When the box is checked, the data is transferred to the NV after the flash memory of the NV is all cleared.When the box is not checked, the data is transferred into the unused area of the flash memory of the NV. The area which has already the transferred data will be invalid, and cannot be used until it is cleared next time. This method requires less transfer time.When the message “Memory is full” is shown on the screen, check this box and transfer the data. C

onnecting with

CPI PLC

Connecting w

ith C

PI PLC

2. When the transfer is completed, the screen is shown on the NV.

Page 31: OMRON GUIA RÁPIDA SERIES NV3 PT

30

■ Screen No. Error:The system memory has an area that is used to switch the NV screen display from the PLC. If the same screen No. stored in the area does not exist in the screen data, the error message “Screen No. Error” shows on the screen. As for the screen data created in this handbook, the area is allocated in D0 address in the PLC. In D0 address in the CX-Programmer, write “0” of the base screen 0.

Write “0” for D0.

Monitoring or changing the PLC parameters from the CX-ProgrammerThe NV-CP1 connection is followed by confirmation of the NV screen operations. This step is explained in the next few pages. This subsection explains the Watch Window to monitor and change the PLC parameters from the CX-Programmer.< Starting up the Watch Window >

On the menu bar, select View – Window – Watch.

Double-click!!

Enter an address.

Enter a value.

< Monitoring the address >Double-click the Watch Window. Enter an address to monitor.When the PLC is connected online, the present value can be read.

< Changing the address value >When the PLC is connected online, double-click the line on the Watch Window, on which the address is registered. Change the value. Put the mark “#” in front of a hexadecimal figure. (E.g. #1A)Put nothing or the mark “&” in front of a decimal figure. (E.g.1234, &1234)

Specify the data type.

※ The values cannot be altered when the PLC is in Run mode.Change the PLC mode to Monitor (Program is in RUN.) or Program (Program is in STOP).

&0D0

ValueAddress

Page 32: OMRON GUIA RÁPIDA SERIES NV3 PT

31

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Testing the Screen OperationTesting the Screen OperationConfirm the object operation on an actual NV.

Operation of switch and lamp objects

1. While you press the RUN switch 2. When you release your finger from the RUN switch

The lamp lights. The lamp goes off.

Operation of data and keyboard objects

When you touch a data object, the screen changes to the Keyboard. You can enter values.

Screen changes to Keyboard

Enter a numerical value.

Touch an object.

Connecting w

ith C

PI PLCC

onnecting with

CPI PLC

Page 33: OMRON GUIA RÁPIDA SERIES NV3 PT

32

Switching screen display from CP1Switching screen display from CP1Switch the NV screen from the CP1 PLC by using its system memory.

Creating a new screen in an existing project

Add a base screen to an existing project. The screen is used to confirm the screen switching operation. 1. Start up the NV-Designer and open a project.

On the Screen Manager window, double-click the No. 1 to open the base screen 1.

Double-click!!

2. Enter a text (or character string) of “Base screen 1”. Align it at the center of the screen. Transfer the screen data to the NV.

Base screen 1

Page 34: OMRON GUIA RÁPIDA SERIES NV3 PT

33

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Setting and confirming the system memory1. On the menu bar, select PT – NV Configuration.

Click!!

2. Click the Basic Setup tab. In the System Memory Area field, you can set or confirm the assigned address.

Word area memory map (Head address = N )N: PLC specified screen No. (PLC NV )N+1: Use prohibitedN+2: Screen No. now in view (NV PLC )

Word area:- PLC specified screen No.Specify a screen No. to show on the NV. It is specified from the PLC in binary.

-Screen No. now in view Write the screen No. now in view on the NV. It is written to the PLC in binary.

※ Cannot specify in BCD.

Switching screens from the CP1 PLC

1. Write “&0” for D0 address, and show the Screen0.

2. Write “&1” for D0 address, and show the Screen1.

When the screens completely switch, “&0” is notified to D2 address.

When the screens completely switch, “&1” is notified to D2 address.

On the CX-Programmer, overwrite the D0 value and switch the screens.

Advanced U

sageA

dvanced Usage

Page 35: OMRON GUIA RÁPIDA SERIES NV3 PT

34

Bit Area (Head address = N )※Extracted only the info related to the backlight.

N Bit10N Bit11N Bit12: Backlight Light/Blink (PLC →NV )N Bit13: Backlight valid flag (PLC →NV )

Meaning Backlight colors: See the table below.*Backlight Light/Blink: 0 = on (normal), 1 = flashBacklight valid flag: Switches between enabling

(1) or disabling (0) the control of Backlight colors and Backlight Light/Blink.

The flag indication follows the backlight setting on the property of each base screen. (On the menu bar, select PT – Screen Property.) The backlight setting can be confirmed on the title bar of each base screen.

■ When the Backlight valid flag is OFF,

Changing Backlight Colors from CP1Changing Backlight Colors from CP1Change the backlight color from the CP1 system memory. ※ The model NV3Q-SR□□ (color) has backlight on and off only.

Setting and confirming the system memoryThe backlight is controlled in the bit area of the system memory.Open the Basic Setup tab on the NV Configuration. Check the addresses assigned in the Bit Area of the System Memory Area field.

Changing the backlight colors from the CP1With the CX-Programmer, operate the W0.10 to W0.13, and change the backlight status.Set the bits for backlight color and backlight Light/Blink. Finally, turn on the Backlight valid flag.(This is the example of NV3W-MG□□□.)

Backlight colors (PLC NV)

OnOnOnOffNV3Q-SW□□ (Color)PinkRedWhiteOffNV3Q-MR□□ (Monochrome)PinkRedWhiteOffNV3W-MR□□□ (Monochrome)

OrangeRedGreenOffNV3W-MG□□□ (Monochrome)

Bit10=ONBit11=ON

Bit10=OFFBit11=ON

Bit10=ONBit11=OFF

Bit10=OFFBit11=OFFState of N Bit10 and Bit11

* Combination of backlight colors by NV models

Green lightW0.10 :ONW0.11 :OFFW0.12 :OFFW0.13 :ON

Red flashW0.10 :OFFW0.11 :ONW0.12 :ONW0.13 :ON

(E.g. :Red flash )

Page 36: OMRON GUIA RÁPIDA SERIES NV3 PT

35

NV-series PT Simple Operation HandbookA

dvanced Usage

Advanced U

sageC

onnecting with

CPI PLC

Connecting w

ith C

PI PLCD

esigning ScreensD

esigning ScreensPreparationPreparation

Connecting PC and PLC via NVConnecting PC and PLC via NVYou can transfer the ladder programs from the PC (or CX-Programmer) to the PLC through the NV to which both the PC and the PLC are connected. You can also monitor the programs from the PC through the NV.

A configuration exampleIn this configuration, you can transfer the ladder programs and monitor the PLC from the CX-Programmer through the NV.

PC

NV3W or NV3Q

Host Link

SYSMAC - CS / CJ / CP-series

PC connection

cable

Setting1. On the CX-Programmer, open a project of a CS-, CJ- or CP-series PLC.

Double-click the New PLC in the project tree. The PLC Model Change dialog box shows.

Double-click!!

2. In the Network Type filed, select the NV type as specified below. Click the OK button.

・NV3W → NV-Thru (Serial Port)・NV3Q → NV-Thru (USB Port)

3. Connect it online.

• The CX-Programmer and the NV-Designer use the same serial port. Therefore, only one of them is online-connected with the NV at a time.

• You can also connect the CX-Programmer with PLC through the NV by selecting PLC – Auto Online - Direct Connection from the menu bar.

※The NV requires no setting.

As of June, 2009Doc. No. JA-090647

Advanced U

sageA

dvanced Usage

Page 37: OMRON GUIA RÁPIDA SERIES NV3 PT

Terms and Conditions of Sale1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed

part of all quotes, agreements, purchase orders, acknowledgments, price lists,catalogs, manuals, brochures and other documents, whether electronic or inwriting, relating to the sale of products or services (collectively, the "Products")by Omron Electronics LLC and its subsidiary companies (“Omron”). Omronobjects to any terms or conditions proposed in Buyer’s purchase order or otherdocuments which are inconsistent with, or in addition to, these Terms.

2. Prices; Payment Terms. All prices stated are current, subject to change with-out notice by Omron. Omron reserves the right to increase or decrease priceson any unshipped portions of outstanding orders. Payments for Products aredue net 30 days unless otherwise stated in the invoice.

3. Discounts. Cash discounts, if any, will apply only on the net amount of invoicessent to Buyer after deducting transportation charges, taxes and duties, and willbe allowed only if (i) the invoice is paid according to Omron’s payment termsand (ii) Buyer has no past due amounts.

4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month orthe maximum legal rate, whichever is less, on any balance not paid within thestated terms.

5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all

costs involved in, obtaining any government approvals required for the impor-tation or sale of the Products.

7. Taxes. All taxes, duties and other governmental charges (other than generalreal property and income taxes), including any interest or penalties thereon,imposed directly or indirectly on Omron or required to be collected directly orindirectly by Omron for the manufacture, production, sale, delivery, importa-tion, consumption or use of the Products sold hereunder (including customsduties and sales, excise, use, turnover and license taxes) shall be charged toand remitted by Buyer to Omron.

8. Financial. If the financial position of Buyer at any time becomes unsatisfactoryto Omron, Omron reserves the right to stop shipments or require satisfactorysecurity or payment in advance. If Buyer fails to make payment or otherwisecomply with these Terms or any related agreement, Omron may (without liabil-ity and in addition to other remedies) cancel any unshipped portion of Prod-ucts sold hereunder and stop any Products in transit until Buyer pays allamounts, including amounts payable hereunder, whether or not then due,which are owing to it by Buyer. Buyer shall in any event remain liable for allunpaid accounts.

9. Cancellation; Etc. Orders are not subject to rescheduling or cancellationunless Buyer indemnifies Omron against all related costs or expenses.

10. Force Majeure. Omron shall not be liable for any delay or failure in deliveryresulting from causes beyond its control, including earthquakes, fires, floods,strikes or other labor disputes, shortage of labor or materials, accidents tomachinery, acts of sabotage, riots, delay in or lack of transportation or therequirements of any government authority.

11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship

except in “break down” situations.b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall

constitute delivery to Buyer;c. All sales and shipments of Products shall be FOB shipping point (unless oth-

erwise stated in writing by Omron), at which point title and risk of loss shallpass from Omron to Buyer; provided that Omron shall retain a security inter-est in the Products until the full purchase price is paid;

d. Delivery and shipping dates are estimates only; ande. Omron will package Products as it deems proper for protection against nor-

mal handling and extra charges apply to special conditions.12. Claims. Any claim by Buyer against Omron for shortage or damage to the

Products occurring before delivery to the carrier must be presented in writingto Omron within 30 days of receipt of shipment and include the original trans-portation bill signed by the carrier noting that the carrier received the Productsfrom Omron in the condition claimed.

13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that theProducts will be free from defects in materials and workmanship for a period oftwelve months from the date of sale by Omron (or such other period expressedin writing by Omron). Omron disclaims all other warranties, express or implied.(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THEPRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIRINTENDED USE. Omron further disclaims all warranties and responsibility ofany type for claims or expenses based on infringement by the Products or oth-erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-gation hereunder shall be, at Omron’s election, to (i) replace (in the formoriginally shipped with Buyer responsible for labor charges for removal orreplacement thereof) the non-complying Product, (ii) repair the non-complyingProduct, or (iii) repay or credit Buyer an amount equal to the purchase price ofthe non-complying Product; provided that in no event shall Omron be responsi-ble for warranty, repair, indemnity or any other claims or expenses regardingthe Products unless Omron’s analysis confirms that the Products were prop-erly handled, stored, installed and maintained and not subject to contamina-tion, abuse, misuse or inappropriate modification. Return of any Products byBuyer must be approved in writing by Omron before shipment. Omron Compa-nies shall not be liable for the suitability or unsuitability or the results from theuse of Products in combination with any electrical or electronic components,circuits, system assemblies or any other materials or substances or environ-ments. Any advice, recommendations or information given orally or in writing,are not to be construed as an amendment or addition to the above warranty.See http://www.omron247.com or contact your Omron representative for pub-lished information.

14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLEFOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANYWAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM ISBASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.Further, in no event shall liability of Omron Companies exceed the individualprice of the Product on which liability is asserted.

15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies andtheir employees from and against all liabilities, losses, claims, costs andexpenses (including attorney's fees and expenses) related to any claim, inves-tigation, litigation or proceeding (whether or not Omron is a party) which arisesor is alleged to arise from Buyer's acts or omissions under these Terms or inany way with respect to the Products. Without limiting the foregoing, Buyer (atits own expense) shall indemnify and hold harmless Omron and defend or set-tle any action brought against such Companies to the extent based on a claimthat any Product made to Buyer specifications infringed intellectual propertyrights of another party.

16. Property; Confidentiality. Any intellectual property in the Products is the exclu-sive property of Omron Companies and Buyer shall not attempt to duplicate itin any way without the written permission of Omron. Notwithstanding anycharges to Buyer for engineering or tooling, all engineering and tooling shallremain the exclusive property of Omron. All information and materials suppliedby Omron to Buyer relating to the Products are confidential and proprietary,and Buyer shall limit distribution thereof to its trusted employees and strictlyprevent disclosure to any third party.

17. Export Controls. Buyer shall comply with all applicable laws, regulations andlicenses regarding (i) export of products or information; (iii) sale of products to“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens ofregulated technology or information.

18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any rightand no course of dealing between Buyer and Omron shall operate as a waiverof rights by Omron. (b) Assignment. Buyer may not assign its rights hereunderwithout Omron's written consent. (c) Law. These Terms are governed by thelaw of the jurisdiction of the home office of the Omron company from whichBuyer is purchasing the Products (without regard to conflict of law princi-ples). (d) Amendment. These Terms constitute the entire agreement betweenBuyer and Omron relating to the Products, and no provision may be changedor waived unless in writing signed by the parties. (e) Severability. If any provi-sion hereof is rendered ineffective or invalid, such provision shall not invalidateany other provision. (f) Setoff. Buyer shall have no right to set off any amountsagainst the amount owing in respect of this invoice. (g) Definitions. As usedherein, “including” means “including without limitation”; and “Omron Compa-nies” (or similar words) mean Omron Corporation and any direct or indirectsubsidiary or affiliate thereof.

Certain Precautions on Specifications and Use1. Suitability of Use. Omron Companies shall not be responsible for conformity

with any standards, codes or regulations which apply to the combination of theProduct in the Buyer’s application or use of the Product. At Buyer’s request,Omron will provide applicable third party certification documents identifyingratings and limitations of use which apply to the Product. This information byitself is not sufficient for a complete determination of the suitability of the Prod-uct in combination with the end product, machine, system, or other applicationor use. Buyer shall be solely responsible for determining appropriateness ofthe particular Product with respect to Buyer’s application, product or system.Buyer shall take application responsibility in all cases but the following is anon-exhaustive list of applications for which particular attention must be given:(i) Outdoor use, uses involving potential chemical contamination or electricalinterference, or conditions or uses not described in this document.(ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviationsystems, medical equipment, amusement machines, vehicles, safety equip-ment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or prop-erty. Please know and observe all prohibitions of use applicable to this Prod-uct. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUSRISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUTENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO

ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THEOVERALL EQUIPMENT OR SYSTEM.

2. Programmable Products. Omron Companies shall not be responsible for theuser’s programming of a programmable Product, or any consequence thereof.

3. Performance Data. Data presented in Omron Company websites, catalogsand other materials is provided as a guide for the user in determining suitabil-ity and does not constitute a warranty. It may represent the result of Omron’stest conditions, and the user must correlate it to actual application require-ments. Actual performance is subject to the Omron’s Warranty and Limitationsof Liability.

4. Change in Specifications. Product specifications and accessories may bechanged at any time based on improvements and other reasons. It is our prac-tice to change part numbers when published ratings or features are changed,or when significant construction changes are made. However, some specifica-tions of the Product may be changed without any notice. When in doubt, spe-cial part numbers may be assigned to fix or establish key specifications foryour application. Please consult with your Omron’s representative at any timeto confirm actual specifications of purchased Product.

5. Errors and Omissions. Information presented by Omron Companies has beenchecked and is believed to be accurate; however, no responsibility is assumedfor clerical, typographical or proofreading errors or omissions.

Page 38: OMRON GUIA RÁPIDA SERIES NV3 PT

OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS

Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON CANADA, INC. • HEAD OFFICE

Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICESão Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICEApodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • [email protected]

OMRON ARGENTINA • SALES OFFICECono Sur • 54.11.4783.5300

OMRON CHILE • SALES OFFICESantiago • 56.9.9917.3920

OTHER OMRON LATIN AMERICA SALES54.11.4783.5300

© 2009 Omron Electronics LLCCat. No. JA-090647 10/09 Specifications are subject to change without notice. Printed in U.S.A.