6
05.-DU-024.RFC.R1 - Berryessa Station Drawings 01 Utility 20131105 OWNER / OPERATOR ACFC & WCD ACWD AREMA AIR AT&T BART CHEV CMC COF COM CSC CSJ CSJ-FO ICG KIND LEVEL 3 / L3 MCI MCWD / MSD MFN MFS OWT PG&E QWEST SBC see SCSD SCVTA / VTA SVRT SCVWD SFWD SJWC SPRINT / SPR SVP USD UPRR xo UTILITY TYPE CATV COMM ELEC FOC, FO G NIT OHE OHT PL PP PT, PETRO RW SD SL SS T, TEL, TELE TS W 0 REV 20131031 20130621 ALAMEDA COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT ALAMEDA COUNTY WATER DISTRICT AMERICAN RAILWAY ENGINEERING MAINTENANCE-OF—WAY ASSOCIATION AIR PRODUCTS AT&T BAY AREA RAPID TRANSIT CHEVRON COMCAST CITY OF FREMONT CITY OF MILPITAS CITY OF SANTA CLARA CITY OF SAN JOSE CITY OF SAN JOSE SMART FIBER ICG COMMUNICATIONS, INC. KINDER MORGAN, INC. LEVEL (3) COMMUNICATIONS MCI, INC. MILPITAS CITY WATER DISTRICT / MILPITAS SANITARY DISTRICT - (CITY OF MILPITAS) METROMEDIA FIBER NETWORK, INC. MFS WORLDCOM ONE WORLD TELECOMMUNICATIONS PACIFIC GAS & ELECTRIC QWEST COMMUNICATIONS INC. SBC COMMUNICATIONS, INC. SANTA CLARA COUNTY SANTA CLARA SEWER DISTRICT SANTA CLARA VALLEY TRANSPORTATION AUTHORITY SILICON VALLEY RAPID TRANSIT SANTA CLARA VALLEY WATER DISTRICT SAN FRANCISCO WATER DEPARTMENT SAN JOSE WATER COMPANY SPRINT SILICON VALLEY POWER UNION SANITARY DISTRICT UNION PACIFIC RAILROAD XO COMMUNICATIONS CABLE TELEVISION COMMUNICATION(S) ELECTRICAL FIBER OPTIC CABLE GAS LINE NITROGEN OVERHEAD ELECTRICAL OVERHEAD TELEPHONE PIPE LINE POWER POLE PETROLEUM LINE RECYCLED WATER STORM DRAIN STREET LIGHT SANITARY SEWER BURIED TELEPHONE TRAFFIC SIGNAL WATER ABBREVIATIONS ABN BFS CIR DBC DFM FT EX FL FM FND HP JT LF MULT NIC NO / NOS PL PROP RCP RR SDMH SSMH TMH TP TRANS TBD UNK UTIL WBO ABANDON BART FACILITY STANDARDS CIRCLE DIRECT BURIED CABLE DISTRIBUTION FEEDER MAIN FEET EXISTING FLOW LINE FORCE MAIN FOUND HIGH PRESSURE JOINT TRENCH LINEAR FEET MULTIPLE NOT IN CONTRACT NUMBER / NUMBERS PIPE LINE PROPOSED REINFORCED CONCRETE PIPE RAILROAD STORM DRAIN MANHOLE SANITARY SEWER MANHOLE TELEPHONE MANHOLE TRANSMISSION PRESSURE TRANSFORMER/TRANSITION TO BE DETERMINED UNKNOWN UTILITY WORK BY OTHERS UTILITY MATERIAL ABS AC, ACP ACWP CCP CD CIP CPC CMP CSP DICL DIP HDPE IP PE PLA / PL PVC RBC RCP SOM STL VCD VCP ACRYLONITRILE—BUTADEINE—STYR EN E ASBESTOS CEMENT PIPE ASBESTOS CEMENT WATER PIPE CONCRETE CYLINDER PIPE CONCRETE DUCT CAST IRON PIPE CONCRETE PIPE CORRUGATED METAL PIPE CORRUGATED STEEL PIPE DUCTILE IRON CEMENT LINED DUCTILE IRON PIPE HIGH DENSITY POLYETHYLENE IRON PIPE POLYETHYLENE PIPE PLASTIC POLYVINYL CHLORIDE REINFORCED BOX CULVERT REINFORCED CONCRETE PIPE SOMATIC COATED PIPE STEEL VITRIFIED CLAY DUCT VITRIFIED CLAY PIPE RFC-RESPONSES TO COMMENTS ( 8 / 9 / 1 3 - 9/19/13) READINESS FOR CONSTRUCTION DESIGNED BY K. MULLER DRAWN BY K. MULLER CHECKED BY B. WAGNER IN CHARGE J. STREEPER 20131031 UTILITY SYMBOLS EXISTING PROPOSED © ^ / o 'i O m rsTi @/o O © / o L/ \ ^ r v i—i i i n L J © A X o . CO o jx><\ // * © CXI /// X STORM DRAIN INLET ELECTRICAL BOX / VAULT ELECTRICAL MANHOLE FIRE HYDRANT MCI TEST POINT MONITORING WELL NATURAL GAS VALVE RAILROAD CONTROL BOX SANITARY SEWER MANHOLE SANITARY SEWER CLEANOUT STORM DRAIN MANHOLE SOLAR PANEL POLE TELEPHONE MANHOLE TELEPHONE JUNCTION BOX UTILITY MARKER UPRR SIGNAL BOX WATER METER WATER VALVE ABANDONED UTILITY REMOVED UTILITY POTHOLE LOCATION UTILITY POLE UTILITY CAP POLE ANCHOR AIR RELEASE VALVE INSIDE PRECAST VAULT TELEMETRY CABLE SPLICE INSIDE PRECAST VAULT CORROSION CONTROL TEST STATION NOTES: 1. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT (USA) TO FIELD VERIFY TYPE AND LOCATION OF UTILITIES BEFORE BEGINNING CONSTRUCTION AND FABRICATING MATERIALS FOR USE IN EXCAVATED AREAS. 2. ALL EXISTING UTILITIES, WHETHER OR NOT SHOWN ON THE DRAWINGS, SHALL BE PROTECTED AT ALL TIMES UNLESS NOTED OTHERWISE. 3. THE PROPOSED PRIVATE UTILITY RELOCATIONS ARE FOR INFORMATION ONLY AND ARE NOT PART OF THIS CONTRACT. THE PRIVATE UTILITY OWNER WILL PERFORM THEIR FINAL DESIGN AND RELOCATIONS. 4. THE PROPOSED PRIVATE RELOCATED UTILITIES BY THIRD PARTIES, AS SHOWN ON THESE UTILITY DRAWINGS, ARE APPROXIMATE BASED UPON INFORMATION PROVIDED BY THE VTA. 5. FOR RIGHT-OF-WAY BOUNDARIES AND UTILITY EASEMENTS REFER TO RIGHT-OF-WAY DRAWINGS. 6. PRIOR TO TRENCHING OVER OR DIRECTLY ADJACENT TO ANY SCVWD PIPELINE, CONTRACTOR MUST POTHOLE TO VERIFY THE SCVWD PIPELINE. TRENCHING WITHIN 1 FOOT OF COVER OVER THE SCVWD PIPELINE SHALL BE BY HAND METHOD ONLY. 7. CITY OF SAN JOSE UTILITIES SHALL BE CONSTRUCTED ACCORDING TO CITY OF SAN JOSE STANDARD SPECIFICATIONS AND STANDARD PLANS. 8. STORM DRAIN PIPE SHALL BE REINFORCED CONCRETE PIPE (CUkSS III) OR POLYVINYL CHLORIDE (PVC) (SDR26) AS INDICATED ON PLANS. 9. SANITARY SEWER PIPE SHALL BE VITRIFIED CLAY PIPE (CLASS ES), POLYVINYL CHLORIDE (PVC]f (C900)) OR HIGH DENSITY POLYETHYLENE (HDPE) AS INDICATED ON PLANS. <!> UTILITY LEGEND EXISTING CATV PROPOSED -CATV- — G — — JT - NIT— — OHE - — P T - -SS- -SD- -CATV- - E — UTILITIES LEGEND LS-01-G-1 UTILITY CODE -FO- — G - -JT- - NIT - -OHE -PT- -RS- -SS- - SD- SL- -T- -W- -RW- CATV LINE BURIED ELECTRICAL LINE BURIED FIBER OPTIC LINE GAS LINE JOINT TRENCH LINE NITROGEN LINE OVERHEAD ELECTRICAL LINE PETROLEUM LINE RIPARIAN SETBACK SANITARY SEWER LINE STORM DRAIN LINE STREET LIGHT LINE BURIED TELEPHONE LINE WATER LINE RECYCLED WATER Santa Clara Valley Transportation Authority ^ NO EXCEPTIONS TAKEN (NET) MAKE CORRECTIONS NOTED (MCN) AMEND AND RESUBMIT (A/R) Any action shown above is subject to the terms of the contract and does not relieve the Contractor of any of its obligations under the contract, including design and detailing. Contract No^ By: DB11002F 3/27/14 Skanska Shimmick Herzog A Joint Venture SUBMITTED n "TnfTi ~T fl|V|| h ICin *^£*7*11-Y.LIN INTERNATIONAL APPROVED W!. SILICON VALLEY BART SILICON VALLEY BERRYESSA EXTENSION LINE, TRACK, STATIONS AND SYSTEMS DESIGN UNIT 024 BERRYESSA STATION SUPPLEMENTAL UTILITY NOTES, ABBREVIATIONS AND SYMBOLS CADD FILENAME C700-S-DC-U001 .dwg SIZE D NTS CONTRACT NO. C700 AREA CODE DC SHEET NO. U001 PAGE NO. 0013

@/o o - partners.Skanska.com · sprint / spr svp usd uprr xo utility type catv ... bfs cir dbc dfm ft ex fl fm fnd hp jt lf mult ... work by others utility material abs ac, p acwp

Embed Size (px)

Citation preview

Page 1: @/o o - partners.Skanska.com · sprint / spr svp usd uprr xo utility type catv ... bfs cir dbc dfm ft ex fl fm fnd hp jt lf mult ... work by others utility material abs ac, p acwp

05.-DU-024.RFC.R1 - Berryessa Station Drawings 01 Utility 20131105 OWNER / OPERATOR

ACFC & WCD

ACWD

AREMA

AIR

A T & T

BART

CHEV

CMC

COF

COM

CSC

CSJ

C S J - F O

ICG

KIND

LEVEL 3 / L3

MCI

MCWD / MSD

MFN

MFS

OWT

P G & E

QWEST

SBC

s e e

SCSD

SCVTA / VTA

SVRT

SCVWD

SFWD

SJWC

SPRINT / SPR

SVP

USD

UPRR

xo

UTILITY TYPE

CATV

COMM

ELEC

FOC, FO

G

NIT

OHE

OHT

PL

PP

PT, PETRO

RW

SD

SL

SS

T, TEL, TELE

TS

W

0

REV

2 0 1 3 1 0 3 1

2 0 1 3 0 6 2 1

ALAMEDA COUNTY FLOOD CONTROL &

WATER CONSERVATION DISTRICT

ALAMEDA COUNTY WATER DISTRICT

AMERICAN RAILWAY ENGINEERING

MAINTENANCE-OF—WAY ASSOCIATION

AIR PRODUCTS

A T & T

BAY AREA RAPID TRANSIT

CHEVRON

COMCAST

CITY OF FREMONT

CITY OF MILPITAS

CITY OF SANTA CLARA

CITY OF SAN JOSE

CITY OF SAN JOSE SMART FIBER

ICG COMMUNICATIONS, INC.

KINDER MORGAN, INC.

LEVEL ( 3 ) COMMUNICATIONS

MCI, INC.

MILPITAS CITY WATER DISTRICT /

MILPITAS SANITARY DISTRICT -

(CITY OF MILPITAS)

METROMEDIA FIBER NETWORK, INC.

MFS WORLDCOM

ONE WORLD TELECOMMUNICATIONS

PACIFIC GAS & ELECTRIC

QWEST COMMUNICATIONS INC.

SBC COMMUNICATIONS, INC.

SANTA CLARA COUNTY

SANTA CLARA SEWER DISTRICT

SANTA CLARA VALLEY

TRANSPORTATION AUTHORITY

SILICON VALLEY RAPID TRANSIT

SANTA CLARA VALLEY WATER DISTRICT

SAN FRANCISCO WATER DEPARTMENT

SAN JOSE WATER COMPANY

SPRINT

SILICON VALLEY POWER

UNION SANITARY DISTRICT

UNION PACIFIC RAILROAD

XO COMMUNICATIONS

CABLE TELEVISION

COMMUNICAT ION(S)

ELECTRICAL

FIBER OPTIC CABLE

GAS LINE

NITROGEN

OVERHEAD ELECTRICAL

OVERHEAD TELEPHONE

PIPE LINE

POWER POLE

PETROLEUM LINE

RECYCLED WATER

STORM DRAIN

STREET LIGHT

SANITARY SEWER

BURIED TELEPHONE

TRAFFIC S IGNAL

WATER

ABBREVIATIONS

A B N

BFS

CIR

DBC

DFM

FT

EX

FL

FM

FND

HP

JT

LF

MULT

NIC

NO / NOS

PL

PROP

RCP

RR

SDMH

S S M H

TMH

TP

TRANS

TBD

UNK

UTIL

WBO

ABANDON

BART FACILITY STANDARDS

CIRCLE

DIRECT BURIED CABLE

DISTRIBUTION FEEDER MAIN

FEET

EXISTING

FLOW LINE

FORCE MAIN

FOUND

HIGH PRESSURE

JOINT TRENCH

LINEAR FEET

MULTIPLE

NOT IN CONTRACT

NUMBER / N U M B E R S

PIPE LINE

P R O P O S E D

REINFORCED CONCRETE PIPE

RAILROAD

STORM DRAIN MANHOLE

SANITARY SEWER MANHOLE

TELEPHONE MANHOLE

TRANSMISSION P R E S S U R E

T R A N S F O R M E R / T R A N S I T I O N

TO BE DETERMINED

UNKNOWN

UTILITY

WORK BY OTHERS

UTILITY MATERIAL

ABS

AC, ACP

ACWP

C C P

CD

CIP

CPC

CMP

CSP

DICL

DIP

HDPE

IP

PE

PLA / P L

PVC

RBC

RCP

SOM

STL

VCD

VCP

ACRYLONITRILE—BUTADEINE—STYR EN E

ASBESTOS CEMENT PIPE

ASBESTOS CEMENT WATER PIPE

CONCRETE CYLINDER PIPE

CONCRETE DUCT

CAST IRON PIPE

CONCRETE PIPE

CORRUGATED METAL PIPE

CORRUGATED STEEL PIPE

DUCTILE IRON CEMENT LINED

DUCTILE IRON PIPE

HIGH DENSITY POLYETHYLENE

IRON PIPE

POLYETHYLENE PIPE

PLASTIC

POLYVINYL CHLORIDE

REINFORCED BOX CULVERT

REINFORCED CONCRETE PIPE

SOMATIC COATED PIPE

STEEL

VITRIFIED CLAY DUCT

VITRIFIED CLAY PIPE

RFC-RESPONSES TO COMMENTS ( 8 / 9 / 1 3 - 9 / 1 9 / 1 3 )

READINESS FOR CONSTRUCTION

DESIGNED BY K. MULLER DRAWN BY K. MULLER CHECKED BY B. WAGNER IN CHARGE J. STREEPER

2 0 1 3 1 0 3 1

UTILITY SYMBOLS EXISTING PROPOSED

© ^ / o

' i

O

m

rsTi

@/o O

© / o L/ \ ^ r

v i — i i i

n L J

• © A

X

o . CO

o jx><\ / /

*

© • • •

C X I

/ / /

X

STORM DRAIN INLET

ELECTRICAL BOX / VAULT

ELECTRICAL MANHOLE

FIRE HYDRANT

MCI TEST POINT

MONITORING WELL

NATURAL GAS VALVE

RAILROAD CONTROL BOX

SANITARY SEWER MANHOLE

SANITARY SEWER CLEANOUT

STORM DRAIN MANHOLE

SOLAR PANEL POLE

T E L E P H O N E MANHOLE

T E L E P H O N E JUNCTION BOX

UTILITY MARKER

UPRR SIGNAL BOX

WATER METER

WATER VALVE

ABANDONED UTILITY

REMOVED UTILITY

POTHOLE LOCATION

UTILITY POLE

UTILITY CAP

POLE ANCHOR

AIR RELEASE VALVE INSIDE PRECAST VAULT

TELEMETRY CABLE SPL ICE INSIDE PRECAST VAULT

CORROSION CONTROL TEST STATION

NOTES:

1. CONTRACTOR S H A L L CONTACT U N D E R G R O U N D SERVICE ALERT ( U S A ) TO FIELD VERIFY TYPE A N D LOCATION OF UTILITIES BEFORE BEGINNING CONSTRUCTION A N D FABRICATING MATERIALS FOR USE IN EXCAVATED AREAS.

2 . ALL EXISTING UTILITIES, WHETHER OR NOT SHOWN ON THE DRAWINGS, S H A L L BE PROTECTED AT ALL TIMES U N L E S S NOTED OTHERWISE.

3 . THE P R O P O S E D PRIVATE UTILITY RELOCATIONS ARE FOR INFORMATION ONLY A N D ARE NOT PART OF THIS CONTRACT. THE PRIVATE UTILITY OWNER WILL PERFORM THEIR FINAL DESIGN AND RELOCATIONS.

4 . THE PROPOSED PRIVATE RELOCATED UTILITIES BY THIRD PARTIES, A S SHOWN ON THESE UTILITY DRAWINGS, ARE APPROXIMATE BASED U P O N INFORMATION PROVIDED BY THE VTA.

5 . FOR R I G H T - O F - W A Y BOUNDARIES AND UTILITY EASEMENTS REFER TO R I G H T - O F - W A Y DRAWINGS.

6 . PRIOR TO TRENCHING OVER OR DIRECTLY ADJACENT TO ANY SCVWD PIPELINE, CONTRACTOR MUST POTHOLE TO VERIFY THE SCVWD PIPELINE. TRENCHING WITHIN 1 FOOT OF COVER OVER THE SCVWD PIPELINE SHALL BE BY HAND METHOD ONLY.

7 . CITY OF SAN JOSE UTILITIES SHALL BE CONSTRUCTED ACCORDING TO CITY OF SAN JOSE STANDARD SPECIFICATIONS AND STANDARD PLANS.

8 . STORM DRAIN PIPE SHALL BE REINFORCED CONCRETE PIPE (CUkSS III) OR POLYVINYL CHLORIDE ( P V C ) ( S D R 2 6 ) AS INDICATED ON PLANS.

9 . SANITARY SEWER PIPE SHALL BE VITRIFIED CLAY PIPE (CLASS ES) , POLYVINYL CHLORIDE ( P V C ] f ( C 9 0 0 ) ) OR HIGH DENSITY POLYETHYLENE ( H D P E ) AS INDICATED ON PLANS.

<!>

UTILITY LEGEND EXISTING

CATV

PROPOSED

- C A T V -

— G —

— JT -

— NIT—

— OHE -

— P T -

- S S -

- S D -

-CATV-

- E —

UTILITIES LEGEND

L S - 0 1 - G - 1 UTILITY CODE

- F O -

— G -

- J T -

- NIT -

-OHE

- P T -

- R S -

- S S -

- SD-

S L -

- T -

- W -

-RW-

CATV LINE

BURIED ELECTRICAL LINE

BURIED FIBER OPTIC LINE

GAS LINE

JOINT TRENCH LINE

NITROGEN LINE

OVERHEAD ELECTRICAL LINE

PETROLEUM LINE

RIPARIAN SETBACK

SANITARY SEWER LINE

STORM DRAIN LINE

STREET LIGHT LINE

BURIED T E L E P H O N E LINE

WATER LINE

RECYCLED WATER

Santa C la ra Val ley T ranspor ta t ion Au tho r i t y

^ N O E X C E P T I O N S T A K E N (NET) M A K E C O R R E C T I O N S N O T E D ( M C N ) A M E N D A N D R E S U B M I T (A /R)

A n y act ion shown above is subject to the terms o f the contract and does not relieve the Cont rac to r of any o f its obl igat ions

under the contract , inc lud ing design and detai l ing.

Cont rac t N o ^

By :

DB11002F

3 / 2 7 / 1 4

Skanska Shimmick Herzog A Joint Venture

SUBMITTED

n " T n f T i • ~ T fl|V|| h I C i n * ^ £ * 7 * 1 1 - Y . L I N INTERNATIONAL

APPROVED

W ! . S I L I C O N V A L L E Y

BART SILICON VALLEY BERRYESSA EXTENSION

LINE, TRACK, STATIONS AND SYSTEMS DESIGN UNIT 0 2 4

BERRYESSA STATION SUPPLEMENTAL UTILITY NOTES, ABBREVIATIONS

AND SYMBOLS

CADD FILENAME

C 7 0 0 - S - D C - U 0 0 1 .dwg SIZE

D NTS CONTRACT NO.

C700 AREA CODE

DC SHEET NO.

U001 PAGE NO.

0013

Page 2: @/o o - partners.Skanska.com · sprint / spr svp usd uprr xo utility type catv ... bfs cir dbc dfm ft ex fl fm fnd hp jt lf mult ... work by others utility material abs ac, p acwp

05.-DU-024.RFC.R2 - Berryessa Station CLOMR Drawings 01 Utility 20140314

8 PVC SD

12" MIN

NOTES:

1. FOR NOTES AND LEGEND, SEE DRAWING DC-U001.

SAND-OIL SEPARATOR SHALL BE JENSEN JP320EE—SO OR APPROVED EQUAL.

INSTALL 4"X6" REDUCERS AT EACH SS CONNECTION TO BERRYESSA STATION PLUMBING OUTLETS AS NEEDED. INVERTS ARE BASED ON LARGER PIPE SIZE BEFORE REDUCER.

n -

M 1 9 5 9 6 0

i ' l © NEC ERAL C SER PE

PROPOSED WATE SJWC (APPROX LOCATIOfJiK S A N D

s t a t i o n 1 9 5 9 6

ss PROTECTION COLLAR EXTEND STUB EAST OF PG&E

UPDATE PG&E AND SS LOCATION IN FD

6 PVC SS —

PROTECTION COLLAR o +®+ o

r o

2 a m

CO - o

J.. V W D 66 STEEL ER DUO o |_4i r— ROW

X X z o s

<

CP S D

" x

' : V '

Z L

...ti \ \ \ \ \ N w—

Santa C l a r a V a l l e y T r a n s p o r t a t i o n A u t h o r i t y - — 9 5 9 9 . 8 7 1 \

235 .02 81,08 '

N O E X C E P T I O N S T A K E N ( N E T ) M A K E C O R R E C T I O N S N O T E D ( M C N ) A M E N D A N D R E S U B M I T ( A / R ) FOR CONTINUATION, 1

5 E -A n y ac t ion s h o w n above is sub jec t to the t e r m s ot the c o n t r a c t

and does no t re l ieve the C o n t r a c t o r o f any o f i ts ob l i ga t i ons u n d e r the c o n t r a c t , i n c l u d i n g design a n d de ta i l i ng .

C o n t r a c t No. : DBI1002F 4 0

6 / 6 / 1 4 PLAN Date GRAPHIC SCALE

0

REV

2 0 1 3 1 0 3 1

2 0 1 3 0 6 2 1

DL 1 1 6 CLOMR AND MISCELLANEOUS UPDATES

RFC-RESPONSES TO COMMENTS ( 8 / 9 / 1 3 - 9 / 1 9 / 1 3 )

READINESS FOR CONSTRUCTION

DESCRIPTION

DESIGNED BY J. STREEPER DRAWN BY K. MULLER CHECKED BY W. WAGNER IN CHARGE J. STREEPER

20140321

Ska Shimmick fierzog A Joint Venture

SUBMITTED

K i n T.Y.LIN INTERNATIONAL

APPROVED

. SILIC EY

BART SILICON VALLEY BERRYESSA EXTENSION

LINE, TRACK, STATIONS AND SYSTEMS DESIGN UNIT 0 2 4

BERRYESSA STATION UTILITY LATERAL CONNECTIONS (SANITARY SEWER)

" S 1 " 5 2 7 + 5 0 TO " S 1 " 5 3 3 + 0 0

CADD FILENAME C700—S—DC—U300.dwg

SIZE SCALE D 1 " = 2 0 '

CONTRACT NO.

C 7 0 0 AREA CODE

DC SHEET NO.

U 3 0 0 PAGE NO.

0014

Page 3: @/o o - partners.Skanska.com · sprint / spr svp usd uprr xo utility type catv ... bfs cir dbc dfm ft ex fl fm fnd hp jt lf mult ... work by others utility material abs ac, p acwp

05.-DU-024.RFC.R2 - Berryessa Station CLOMR Drawings 01 Utility 20140314

NOTES:

1. FOR NOTES AND LEGEND, SEE DRAWING DC-U001.

2. INSTALL 4"X6" REDUCERS AT EACH SS CONNECTION TO BERRYESSA STATION PLUMBING OUTLETS. INVERTS ARE BASED ON LARGER PIPE SIZE BEFORE REDUCER.

ft ^ rAO

PROPOSED SD BY C742 CONTRACT (APPROX LOCATION)

$ 50 PROPOSED 3Y

LOCATI

y SO

+ • * - / ^ A SD

SD 24

Santa C l a r a Va l l ev T r a n s p o r t a t i o n A u t h o r i t y

EXTEND STUB EAST OF PG&E

N O E X C E P T I O N S T A K E N ( N E T ) / M A K E C O R R E C T I O N S N O T E D ( M C N )

A M E N D A N D R E S U B M I T ( A / R )

i o A n y ac t ion s h o w n above is sub jec t to the te rms of the c o n t r a c t a n d does not re l ieve the C o n t r a c t o r o f any o f i ts ob l i ga t i ons

u n d e r the c o n t r a c t , i n c l u d i n g design and de ta i l i ng . o

94 ~ 6 PVC

r n CO -SCVWD 50 i ESMT C o n t r a c t N o

Bv: V / i /

L>lil 101)2 V m UPDATE PG&E AND

SS LOCATION IN FD 6 / 6 / 1 4 ROW Date:

« ( / ) o

— s O SCVWD 6 6 STEEL W PER DU13

CROSSING--' — ^ J

I L — ELEC DUCTBANK SEE ELECTRICAL PU\NS i S 4 N v 8 0 . 1 2

T\ MIN CLEAR L _ TOP 79 D1 X O S " X % l W — so

v I < w X

0 ti- -6 ~ 6 PVC S=9.1 %

SD- SD

X - w

j r

U

'D. •w _ )

D r - FOR FIRE SERVICE, SEE D U 0 2 6 \

-X. x ROW D I

--

/ / 536 / saa

ccmss

c o k p - r ZS 96

FOR S^ST^R \CK

5 ^ 6 zX — =

3 STL CHEV • I ^ I MCI/CHEV 10* JOINT ESMT

TCE STORAGE CONTAINERS

0' 20' 40' PLAN

GRAPHIC SCALE

2 1

0 REV

2 0 1 3 1 0 3 1

2 0 1 3 0 6 2 1

DL 1 1 6 CLOMR AND MISCELLANEOUS UPDATES

RFC-RESPONSES TO COMMENTS ( 8 / 9 / 1 3 - 9 / 1 9 / 1 3 )

READINESS FOR CONSTRUCTION

DESIGNED BY J. STREEPER DRAWN BY K. MULLER CHECKED BY W. WAGNER IN CHARGE J. STREEPER

20140321

Ska Shimmick

lerzog A Joint Venture

1436 California Circle Milpitas, California 95035

SUBMITTED

- r I I v i i f i 4 / M I ^ .

I Q H T" Y - L I N INTERNATIONAL

APPROVED

L SILICON VALLEY

BART SILICON VALLEY BERRYESSA EXTENSION

LINE, TRACK, STATIONS AND SYSTEMS DESIGN UNIT 024

BERRYESSA STATION UTILITY LATERAL CONNECTIONS (SANITARY SEWER)

" S 1 " 5 3 3 + 0 0 TO " S 1 " 5 3 8 + 5 0

CADD FILENAME C700-S-DC-U301 .dwg

SIZE SCALE D 1 " = 2 0 '

C700 AREA CODE

DC SHEET NO.

U301 PAGE NO.

0015

Page 4: @/o o - partners.Skanska.com · sprint / spr svp usd uprr xo utility type catv ... bfs cir dbc dfm ft ex fl fm fnd hp jt lf mult ... work by others utility material abs ac, p acwp

05.-DU-024.RFC.R2 - Berryessa Station CLOMR Drawings 01 Utility 20140314

N O T E S :

1. FOR NOTES A N D L E G E N D , SEE DRAWING D C - U 0 0 1 .

2 . INSTALL T H R U S T B L O C K S AT A N G L E P O I N T S PER CSJ DWG NO. W - 7 A N D W - 8 .

3 . F IRE WATER SERVICE TO B E R R Y E S S A STATION IS S U B J E C T T O C H A N G E . S E E D U 0 2 6 FOR DESIGN INFORMATION.

c r t K • A * ^ fa- * u

s i P R O P O S E D WA7EW BY

SJWC / { A P P R Q K

LOCATION) r~h~-

S s fiCF?Ry£

S S A s T A T l o N

Way s s

SD S S

w S D + 0 0

SD

UD s s

UPDATE PG&E AND SS LOCATION IN FD 0

ss

SS s

^ I

_ T 2 ' i

* i r

| o I - — ^ . 1 J., I ° b r T ~ ^

y , X W X Z E 6 1 6 2 2 0 4 . 5 3

1 5 ' & 2 2 . 5 V H € 8

O E 3 j l

O SD SD 3 2 :

- X I

--FN 'V S, \ V, \ V, VV \ \ \ "

1 X :

n

...ti V V V V VF i \ \ \ \ \ \ ^ p - ^ r -D U 0 2 6 WATER

M C I / C H E V ~ m i M T r c u T Santa Clara Val ley T ranspor ta t ion A u t h o r i t y

N O E X C E P T I O N S T A K E N (NET) _ y / M A K E C O R R E C T I O N S N O T E D ( M C N )

A M E N D A N D R E S U B M I T (A/R) - - P I T w r w

R0%~\* ^ \ n v act ion shown above is subject to the terms ot the contract and does not relieve the Cont rac to r of any o f its obl igat ions

under the contract , inc luding design and detai l ing. SEE NOTE 3

Cont rac t No.:

B>:

DBI IU02K

6 / 6 / 1 4 PLAN Date:

GRAPHIC S C A L E

0 REV

20131031

20130621

DL 116 CLOMR AND MISCELLANEOUS UPDATES

RFC-RESPONSES TO COMMENTS ( 8 / 9 / 1 3 - 9 / 1 9 / 1 3 )

READINESS FOR CONSTRUCTION

DESCRIPTION

DESIGNED BY J . S T R E E P E R DRAWN BY K . M U L L E R CHECKED BY W. WAGNER IN CHARGE J . S T R E E P E R

2 0 1 4 0 3 2 1

Ska Shimmick fierzog A Joint Venture

SUBMITTED

a a - T I I V I I 1 -

K i n T-Y-LIM INTERNATIONAL

APPROVED

5 1 L I C EY

B A R T S I L I C O N V A L L E Y B E R R Y E S S A E X T E N S I O N

LINE, TRACK, STATIONS AND SYSTEMS DESIGN UNIT 0 2 4

B E R R Y E S S A S T A T I O N

U T I L I T Y L A T E R A L C O N N E C T I O N S ( W A T E R )

" S 1 " 5 2 7 + 5 0 T O " S 1 " 5 3 3 + 0 0

CADD FILENAME C 7 0 0 — S — D C — U 4 0 0 . d w g

SIZE SCALE D 1 " = 2 0 '

CONTRACT NO. C700

AREA CODE

DC SHEET NO.

U 4 0 0 PAGE NO.

0016

Page 5: @/o o - partners.Skanska.com · sprint / spr svp usd uprr xo utility type catv ... bfs cir dbc dfm ft ex fl fm fnd hp jt lf mult ... work by others utility material abs ac, p acwp

05.-DU-024.RFC.R2 - Berryessa Station CLOMR Drawings 01 Utility 20140314

- 2 4 DIA FRAME, COVER, A N D A D J U S T M E N T RINGS

P R E C A S T S L A B 4 8 DIA WITH 2 4 " O P E N I N G

H S 2 0 RATED

BASE PER C S J -STD DWG NO. D —1 2

N O T E S :

1. FOR NOTES A N D L E G E N D , SEE DRAWING D C - U 0 0 1 .

- 4 }

< y

- ^ U D ATER P R O P O S E D

SJWC~TARJ U J C A T I O N )

°ERRYfr SSA

station Wficr

SD ss SHALLOW STORM MANHOLE DETA L

w — S D SS + 0 0

ss SD

UD SS

ss UPDATE PG&E AND SS LOCATION IN FD s

N 1 9 5 9 5 8 4 . 2 2 O 6 4 6 2 - 2 3 9 . 8 2 •HK O

INV 8 2 . 6 0 4 5 " HOR B E N D

r o •S -A , . , PVC - v

N 1 9 5 9 5 8 5 . 9 2

I T )

E -6J 6 2 2 3 6 . 9 8 1

_ 4 5 " FFCRT^-BEND^ANA.

VERT ICAL R I S E f T P E R -C S J DWG NO. D - 1 7

\ T E R A L CO

- o

SCVWD 6 6 ^ S T E E L W Q J. o i - ^ y p D Q - U 3 p O ION | Z

X X

Z O S

w I o | — — | o L a

S E E |DUO2£_ EQR S A N I T A R Y

L E 3 l U _ _ S D -SD S D 7 S D S D

> L Z _ ''W X _ ^ . - V L r O AND D 0 T A B L E

^ A ! d L

~ |~ <£. S 2 TRACK |

ffii H w —

Santa Clara Va l ley T ranspor ta t ion A u t h o r i t y

4 z l - — —

N O E X C E P T I O N S T A K E N ( N E T ) M A K E C O R R E C T I O N S N O T E D ( M C N ) A M E N D A N D R E S U B M I T (A /R)

^ W W Any action shown above is subject to the terms o f the contract

and does not relieve the Cont rac tor o f any o f its obl igat ions under the contract , inc lud ing design and detai l ing.

3 4 . 5 K V / T R A I N

C O N T R O L 7 C O M M D U C T B A N K S E E D U 0 2 6

- 0 ' 2 0 ' 4 0 '

Contract N o j DB11002F

By: t / w o J . e Date: 6 / 6 / 1 4

PLAN G R A P H I C S C A L E

0 REV

20131031

20130621

DL 116 CLOMR AND MISCELLANEOUS UPDATES

RFC-RESPONSES TO COMMENTS ( 8 / 9 / 1 3 - 9 / 1 9 / 1 3 )

READINESS FOR CONSTRUCTION

DESCRIPTION

DESIGNED BY J . S T R E E P E R DRAWN BY K . M U L L E R CHECKED BY W. WAGNER IN CHARGE J . S T R E E P E R

2 0 1 4 0 3 2 1

Ska Shimmick fierzog A Joint Venture

SUBMITTED

a a - T I I V I I 1 -

K i n T-Y-LIM INTERNATIONAL

APPROVED

EY I. SILIG

B A R T S I L I C O N V A L L E Y B E R R Y E S S A E X T E N S I O N

LINE, TRACK, STATIONS AND SYSTEMS DESIGN UNIT 0 2 4

B E R R Y E S S A S T A T I O N

UT IL ITY L A T E R A L C O N N E C T I O N S ( S T O R M D R A I N )

" S 1 " 5 2 7 + 5 0 T O " S 1 " 5 3 3 + 0 0

CADD FILENAME C 7 0 0 — S — D C — U 6 0 0 . d w g

SIZE SCALE D 1 " = 2 0 '

CONTRACT NO. C700

AREA CODE

DC SHEET NO.

U 6 0 0 PAGE NO.

0020

Page 6: @/o o - partners.Skanska.com · sprint / spr svp usd uprr xo utility type catv ... bfs cir dbc dfm ft ex fl fm fnd hp jt lf mult ... work by others utility material abs ac, p acwp

05.-DU-024.RFC.R2 - Berryessa Station CLOMR Drawings 01 Utility 20140314

NOTES:

1. FOR NOTES AND LEGEND, SEE DRAWING DC-U001.

2. SD PIPES FROM BUILDING ARE 3 TYP. INSTALL 3 X6 OR 3"X8" REDUCERS AS NEEDED. V-

q \ 0 PROPOSED C742 CONTRAer^APPROX LOCATION)

\ \ <P ^ 0

\ V P

\ i f iX®

a 5 0

3d

/ SO

V A i — Y ^ W SD

S D

— Santa C la ra Val ley I ranspor tat ion Au tho r i t y

NO E X C E P T I O N S T A K E N (NET) M A K E C O R R E C T I O N S N O T E D ( M C N ) A M E N D A N D R E S U B M I T (A/R) PROPOSED SS BY 0742

CONTRACT (APPROX LOCATION) — E

Any act ion shown above is subject to the terms ot the contract and does not rel ieve the Cont rac to r o f any o f its obl igat ions

under the contract , inc lud ing design and detai l ing. o

SS o UPDATE PG&E AND SS LOCATION IN FD n Cont rac t No.

By:

OB I I002f SCVWD 50 ' ESMT n N 1959508.62 6 / 6 / 1 4 LO

3 ' ^ E 6

H Dale ROW

,INV-83720 LATERAL-CON NECTICN

- ^ r - -

S=0_52% . \

U95$51-2t65— T * l \

Ul « ' O tL -12531.11:25

- F - 3 1

r s = ~ 6 _ - o

/ E 6165282.3 / IN.IV/ 57

^ i 3 ' L _ N 1959478.70 SCVWD' 66 STEEL PER DU13 61 62257.73

INV 83.17 ' CONNECTION ON ; C J

3 5 ' ~ 6 PVC - X s = e r 7 s %

< 3gX «/// / / /

39 ~ 8 PVC / - 66 '~6 " \PVC Vr ~ S=0.78%

PV SD SD _ ^ - _ 6 6 _ l s c v y ^

~ n o z ~ J l I L /— SEE-VDU026 koR _ ft SANITARY SEWER AND

/ / FIRE WATER SERVICES

• X w J - i A . — - ^ - Z ^ R O W

-" V n N 1959375.90 -W-534 35 + 0 l/V 53+ 5vV8 E 6162276

FO FOR CONTINUATION, SEE DRAWING M204 6" INV 84.38 ' - - i /

95941 0.54 E 6162267.55 FOR CONTINUATION, SE^ DRAWING M204 T r~iNVW84.50'

\ N 1959580.55 \ E 6162240.74 ^ ^ 1 9 5 9 5 4 6 . 6 0 ^ ^

LATERAL CONNECTION INV 82.90 ' FOR CONTINUATION, 6 » x 8 " REDUCER AND SEE DRAWING M203 i ATFRAI CONNFCTION

SS

STL

£ FOR

3 * 6 ZA SEE

8" £TL| CHEV \;

m -OR CONTINUATION

- PT

2 0 40' PLAN

GRAPHIC SCALE

Ska DESIGNED BY J. STREEPER

CADD FILENAME C700—S—DC—U601 .dwq LINE, TRACK, STATIONS AND SYSTEMS

DESIGN UNIT 0 2 4 BERRYESSA STATION

UTILITY LATERAL CONNECTIONS (STORM DRAIN) " S 1 " 5 3 3 + 0 0 TO " S I " 5 3 8 + 5 0

C\s 1 436 Californio Circle Iv Milpitos, Californio 95035 DRAWN BY

K. MULLER SIZE SCALE D 1 " = 2 0 ' erzog A Joint Venture CHECKED BY

W. WAGNER 20140321 DL 116 CLOMR AND MISCELLANEOUS UPDATES r V 7 7 9 . SILICON VALLEY

BART SILICON VALLEY BERRYESSA EXTENSION

CONTRACT NO. REV RFC-RESPONSES TO COMMENTS ( 8 / 9 / 1 3 - 9 / 1 9 / 1 3 ) 20131031 C700 | G | | ^ J T-Y-LIM INTERNATIONAL IN CHARGE

J. STREEPER 20130621 READINESS FOR CONSTRUCTION AREA CODE

DC SHEET NO.

U601 PAGE NO.