Introduction This guide presents an overview of the Netra™ 440 server installation. For complete installation instructions, refer to the Netra 440 Server Installation Guide. Documentation You can view, print, or download manuals from the Sun™ documentation web site: http://www.sun.com/documentation Netra 440 Server Release Notes (817-3885-xx) Latest product updates Netra 440 Server Product Overview (817-3881-xx) Product overview information Netra 440 Server Installation Guide (817-3882-xx) Detailed rackmounting, cabling, power-on, and configuring information Netra 440 Server Service Manual (817-3883-xx) Service information Netra 440 Server System Administration Guide (817-3884-xx) Administration information Netra 440 Server Diagnostics and Troubleshooting Guide (817-3886-xx) Diagnostics and troubleshooting information Sun Advanced Lights Out Manager User’s Guide for the Netra 440 Server (817-5481-xx) Advanced Lights Out Manager (ALOM) software information Netra 440 Server Safety and Compliance Manual (817-6225-xx) Essential safety and compliance information Shipment Contents Besides the server (shown on the left), the ship kit contains: Note – The DC connectors are for the DC-powered servers only. Use the separately ordered AC cables with the AC-powered server. Antistatic wrist strap RJ-45 serial console cable M5 nut kit RJ-45 to DB-9 adapter RJ-45 to DB-25 adapter Rackmount kit DC connectors (For DC servers only) Netra 440 Server Quick Start Guide

Netra 440 Server Quick Start Guide - Oracle · 1. Viewing Front Components 1. Press in on the door release latches to lower the front door. 2. View the components accessible from

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Netra 440 Server Quick Start Guide - Oracle · 1. Viewing Front Components 1. Press in on the door release latches to lower the front door. 2. View the components accessible from

Netra™ 440 Server Quick Start Guide

IntroductionThis guide presents an overview of the Netra™ 440 serverinstallation.

For complete installation instructions, refer to theNetra 440 Server Installation Guide.

DocumentationYou can view, print, or download manuals from theSun™ documentation web site:http://www.sun.com/documentation

■ Netra 440 Server Release Notes(817-3885-xx)Latest product updates

■ Netra 440 Server Product Overview(817-3881-xx)Product overview information

■ Netra 440 Server Installation Guide(817-3882-xx)Detailed rackmounting, cabling, power-on, andconfiguring information

SB

NoA

Netra 440 Server Service Manual(817-3883-xx)Service information

Netra 440 Server System Administration Guide(817-3884-xx)Administration information

Netra 440 Server Diagnostics and Troubleshooting Guide(817-3886-xx)Diagnostics and troubleshooting information

Sun Advanced Lights Out Manager User’s Guide for theNetra 440 Server (817-5481-xx)Advanced Lights Out Manager (ALOM) softwareinformation

Netra 440 Server Safety and Compliance Manual(817-6225-xx)Essential safety and compliance information

hipment Contentsesides the server (shown on the left), the ship kit contains:

ote – The DC connectors are for the DC-powered serversnly. Use the separately ordered AC cables with theC-powered server.

Antistaticwrist strap

RJ-45 serialconsole cable

M5 nut kit

RJ-45 toDB-9 adapter

RJ-45 to DB-25adapter

Rackmount kit

DC connectors(For DC servers only)

Page 2: Netra 440 Server Quick Start Guide - Oracle · 1. Viewing Front Components 1. Press in on the door release latches to lower the front door. 2. View the components accessible from

The shipment also contains these documents:Important Safety Information for Sun Hardware (816-7190-xx),Sun Netra 440 Server Product Documentation (817-4755-xx),Binary Code Licenses (816-4835-xx), Sun Install Check Tool(817-0440-xx), and this guide.

1. Viewing Front Components1. Press in on the door release latches to lower the front

door.

2. View the components accessible from the front panel.

2. Mount Server to RackDetailed instructions on mounting the server in a rack arein the Netra 440 Server Installation Guide. The following rackmount kits are available for the Netra 440 server.

■ 19-inch 4-post sliding or hardmount■ 19-inch 2-post hardmount■ 23-inch 2-post hardmount■ 600 mm 4-post hardmount

Door release latches

SCC

System configurationcard reader

Rotary switch

On/Standbybutton

Hard drives

Fan trays 0-2

Power distributionDVD driveboard

Fh

1

2

3

4

ollowing are the basic instructions for the 19-inch 4-postardmount rack mount kit:

. Get the front hardmount brackets from the rack kitand secure the front brackets to the sides of the server.

. Get the two rear mount support brackets from therack kit and install the rear mount support brackets atthe rear of the server.

. Lift the server to the desired location in the rack.

. Secure the front hardmount brackets attached to thesides of the server to the front of the rack.

Page 3: Netra 440 Server Quick Start Guide - Oracle · 1. Viewing Front Components 1. Press in on the door release latches to lower the front door. 2. View the components accessible from

5. Get the two rear mount flanges from the rack kit and,at the rear of the rack, use the two captive screws tosecure the two rear mount flanges to the rear mountsupport brackets that are attached to the server.

6. Using two screws for each rear mount supportbracket, secure the rear mount support brackets to therear of the rack.

3. Attach Cables

AlarmDB-15 connector; use this port to connect to the centraloffice alarming system.

SerialDB-9 connector; use this port (TTYB) for general purposeserial data transfer.

USBUse the ports (USB0–3) to connect to external USB devices.

Captive screws tosecure flange torear of server

Screws to secureflange to rack

AlarmSerial

USBEthernet

SCSI Net MGTSerial MGT

AC power OR DC power Groundstuds

You cannot mix AC and DC power supplies in the same server

ERt

SUe

SRuR

NRc

AC

DA

GC

Nc

4

Np

1

thernetJ-45 connectors; use these ports (NET0, NET1) to connect

o autonegotiating 10/100/1000BASE-T Ethernet networks.

CSIltra320 LVD SCSI connector; use this port to connect to

xternal SCSI devices.

ERIAL MGTJ-45 connector; use this serial port for server managementsing the ALOM software. If needed, use the suppliedJ-45 to DB-9 or RJ-45 to DB-25 adapters.

ET MGTJ-45 connector; use this port for making an Ethernetonnection to the ALOM software.

C Power (AC Server Only)onnect the AC power cords to the AC power source.

C Power (DC Server Only)ssemble DC connectors and connect to DC power source.

round Studs (DC Server Only)onnect to protected earth ground.

ote – Refer to the Netra 440 Server Installation Guide foromplete cabling instructions.

. Power On Server

ote – The server goes into Standby mode as soon as theower cables are connected to the power source.

. Make sure the rotary switch is in the Normal (|)position before powering on the server.

SCC

Forced Normal Locked

Diagnostics

standby

Page 4: Netra 440 Server Quick Start Guide - Oracle · 1. Viewing Front Components 1. Press in on the door release latches to lower the front door. 2. View the components accessible from

2. Set up a console connection to the server using theserver’s SERIAL MGT port.Refer to the Netra 440 Server Installation Manual forcomplete instructions.

3. Power on server either from the keyboard or bypressing the system power button at the front of theserver.

Note – Refer to the Netra 440 Server Installation Manual forcomplete power on and configuration instructions.

Indicator Overview

Front Panel Indicators

SCC

System statusHard drives Fan trays 0-2Alarms

Part No. 817-4756-11, Rev. AAugust 2004

Sun Microsystems, Inc.www.sun.com

Copyright 2004 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Thirdmay be derived from Berkeley BSD systems, licensed from U. of CA. Sun, Sun Microsystems, ththe U.S. and in other countries. All SPARC trademarks are used under license and are trademarU.S. Government Rights—Commercial use. Government users are subject to the Sun Microsys

Copyright 2004 Sun Microsystems, Inc. Tous droits réservés. Distribué par des licences qui en rpolices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun. DesCalifornie. Sun, Sun Microsystems, le logo Sun, Netra, et Solaris sont des marques de fabriqueles marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marque

Rear Panel Indicators

Note – Refer to the Netra 440 Server Installation Manual forthe description of these indicators.

System status NET MGT

Ethernet connection

Power supply

-party software, including font technology, is copyrighted and licensed from Sun suppliers. Portionse Sun logo, Netra, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. inks or registered trademarks of SPARC International, Inc. in the U.S. and in other countries.tems, Inc. standard license agreement and applicable provisions of the FAR and its supplements.

estreignent l’utilisation. Le logiciel détenu par des tiers, et qui comprend la technologie relative auxparties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université deou des marques déposées de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutess déposées de SPARC International, Inc. aux Etats-Unis et dans d’autres pays.