47
Codice: B100HL_105_110D_CV_03_07_IT_GB NECS-N 0152 - 0612 38 - 151 kW Pompe di calore condensate ad aria Reverse cycle air/water heat pumps Refrigerante Refrigerant Serie Serie Size Range NECS-N / NECS-ND R410A Unità con 2 compressori, 1 circuito, Compressori Scroll Evaporatore a piastre inox saldobrasate Disponibile in versione con Recupero Parziale Disponibile con Kit Idronico Integrato IDRORELAX Network Unit Units with 2 compressor, 1 circuit, Scroll compressors Steel braze-welded plate evaporator Available with Partial Recovery Available with Integrated Hydronic Kit IDRORELAX Network Unit 0152 - 0612 38 - 151 kW

NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

Cod

ice:

B10

0HL_

105_

110D

_CV

_03_

07_I

T_G

B

NE

CS

-N

015

2 -

0612

38 -

151

kW

Pompe di calore condensate ad ariaReverse cycle air/water heat pumps

RefrigeranteRefrigerant

SerieSerie

SizeRange

NECS-N / NECS-ND

R410A

Unità con 2 compressori, 1 circuito, Compressori ScrollEvaporatore a piastre inox saldobrasateDisponibile in versione con Recupero ParzialeDisponibile con Kit Idronico IntegratoIDRORELAX Network Unit

Units with 2 compressor, 1 circuit, Scroll compressorsSteel braze-welded plate evaporatorAvailable with Partial RecoveryAvailable with Integrated Hydronic KitIDRORELAX Network Unit

0152 - 061238 - 151 kW

Page 2: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

Presentazione prodotto

Sbrinamento Autoadattivo

Accessori

Caratteristiche controllore

Dati tecnici generali

Prestazioni in refrigerazione

Prestazioni in pompa di calore

Prestazioni desurriscaldatore

Limiti di funzionamento

Dati idraulici

Dati elettrici

Livelli sonori a pieno carico

Disegni dimensionali

Gruppo idronico (optional)

pg. n° I

pg. n° IV

pg. n° 1

pg. n° 4

pg. n° 5

pg. n° 10

pg. n° 16

pg. n° 22

pg. n° 26

pg. n° 27

pg. n° 28

pg. n° 29

pg. n° A1

pg. n° B1

I dati contenuti possono essere variati senza obbligo di preavvisoAll specification and data are subject to change without notice

Produced presentation

Auto Tuning Defrost

Accessories

Electronic control features

General technical data

Cooling capacity performance

Heat pump capacity performance

Desuperheater capacity performance

Operating range

Hydraulic data

Electrical data

Full load sound level

Dimensional drawings

Hydronic group (optional)

SOMMARIO SOMMARY

B100HL_105_110D_CV_03_07_IT_GB

NECS-N 0152 - 0612

Questa azienda è associataal Programma di Certificazione Eurovent.I prodotti sono elencati nelDirectory dei prodotti certificati.

This company partecipatesin the Eurovent Certification Programme.

The products are listed in theDirectory of certified products.

Company quality systemcertified to UNI EN ISO 9001

Azienda con sistema qualitàcertificato UNI EN ISO 9001

Page 3: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

I B100HL_105_110D_CV_03_07_IT_GB

Perché R410A?Sebbene l’R410A sia una miscela, esso si comporta comeun gas puro, con un trascurabile glide di temperatura.L’R410A si distingue per un’ottima conduttività termica epermette di ottenere sistemi con elevate efficienze.L’R410A è inoltre un gas ecologico, sia perché grazie allesue alte efficienze permette di contenere i consumi di ener-gia elettrica e perciò di emissioni di CO2, sia perché non èdannoso per l’ozono (ODP = 0). Il compressore scroll, ap-positamente riprogettato per l’utilizzo con il nuovo gas, pre-senta caratteristiche costruttive di maggiore compattezzae silenziosità.

Versioni SilenziatePer tutte le taglie sono disponibili due livelli di riduzionedella rumorosità: versione silenziata e versionesupersilenziata. I bassi livelli di rumorosità sono ottenuticon una riduzione della velocità di rotazione dei ventilatoried il corretto funzionamento dell’unità viene garantitoall’ottimizzazione della circuitazione e dal generosodimensionamento delle batterie.

NECS, la nuova proposta CLIMAVENETA ad R410A

- Compressori scroll, caratterizzati da alta efficienza, bas-se vibrazioni, bassi livelli di emissione sonora.

- Flessibilità di gamma. Sono disponibili nel range 38 -151 kW con 11 taglie e 2 versioni.

- Efficienza ai carichi parziali con EER > 4,3

- Nuovo controllore con QuikMind

- Idrorelax, per realizzare le tue idee

Why R410A?Though R410A is a blend, it behaves just like a pure gasand features a negligible temperature glide. Thanks to itsoutstanding heat conductivity, R410A contributes towardsachieving elevated system efficiency. R410A is also anecological gas, both because its elevated efficiencyreduces electricity consumption and, consequently, CO2,emissions and because it does not damage the ozone layer(ODP = 0). The scroll compressor has been expresslyredesigned for use with the new gas and is now even morecompact and silent than before.

Low-Noise VersionsTwo noise reduction versions are available for all sizes:low noise and super low noise. Low noise levels areachieved by reducing fan speed while the circuitry hasbeen optimised and the coils generously sized to ensurethe unit works correctly.

NECS, the CLIMAVENETA R410A range

- Scroll compressors, featuring higt efficiency, lowvibrations and low noise emissions.

- Range flexibility. A good 11 size and up to 2 version areavailable in the 38 - 151 kW range.

- Part load efficiency with EER > 4,3

- New controller with QuikMind

- Idrorelax, in order to realize your ideas.

Climaveneta presenta le nuove unità NECS(New Evolution Climaveneta System),refrigeratori (pompe di calore) concompressori rotativi di tipo Scroll ad R410A.La serie NECS è stata progettata,coerentemente alla cultura aziendale, peroffrire prodotti di altissima qualità e tecnologia,orientati alla massima efficienza energeticaed al contenimento delle emissione acustiche.

Climaveneta presents its new NECS (NewEvolution Climaveneta System) range ofchillers (heat pumps) fitted with R410A rotaryscroll compressors. Consistently withcorporate culture, the NECS series exploitscutting-edge technology to achieveextremely high levels of quality, focusing onmaximum energy efficiency and minimumnoise emissions.

L’efficienza energetica (EER)L’efficienza energetica (EER) delle unità Climaveneta èulteriormente incrementata dauna progettazione delle su-perfici di scambio, batterie escambiatori a piastre mirataalla economicità di eserciziodelle unità. Tale filosofiaprogettuale consente, oltre albeneficio di raggiungere EERprossimi a 2,9, ottenereelevatissimi l ivell i diaffidabilità ed incrementare lavita utile del compressore.

The energy efficiency (EER)The energy efficiency (EER) of these Climaveneta units is

further enhanced thanks the factthat the design of the heatexchange surfaces, coils andplate exchangers was focusedon minimising running costs.well as achieving an EER closeto 2.9, this design focusachieves very high levelsreliability and lengthens theworking life of the compressor.

Page 4: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

II B100HL_105_110D_CV_03_07_IT_GB

Norme ARI IPLV ARI = (1*EER100% + 42*EER75% + 45*EER50% + 12*EER25%) /100 ARI Standard

Peso = quantità di energia prodatta delle rispettive condizioni di carico Energy = percentage of total power produced in the various conditions

Indici energetici IPLV ed ESEERL’attenzione verso i consumi elettrici delle macchine de-stinate al condizionamento dell’aria comincia a farsi senti-re sempre di più anche in campo europeo.Negli Stati Uniti da moltissimi anni non si fa riferimentoalla sola efficienza nelle condizioni di progetto, ma si uti-lizza un indice di valutazione che tenga conto del margi-nale funzionamento dell’unità alle condizioni di progetto edel maggiore utilizzo in condizioni di carico parziale, conaria esterna inferiore a quella di progetto ed in condizionidi parzializzazione dei compressori frigoriferi installati.L’indice di valutazione adottato negli Stati Uniti viene chia-mato IPLV (Integrated Part Load Value) ed è definito dallenorme emanate dall’ARI (American Refrigeration Institu-te).

dove EER100%, EER75%, EER50%, EER25% sono le efficienzedel gruppo frigorifero nelle varie condizioni di carico (ri-spettivamente 100% - 75% - 50% e 25%), calcolate nellecondizioni di temperatura di aria esterna qui di seguito ri-portate. La temperatura dell’acqua in uscita all’evaporato-re è considerata costante a 6,7 °C in tutte le condizioni dicarico, con un delta di 5 °C nella condizione di pieno ca-rico.I moltiplicatori 1, 42, 45 e 12 sono rispettivamente i pesidelle efficienze frigorifere nelle varie condizioni di carico,statisticamente dedotti dall’ARI sulla base di analisi svol-te, per dioverse tipologie di edifici e condizioni di eserci-zio, in 29 diverse città Americane.

Acqua uscita evaporatore 6,7°C costanteDeltaT a pieno carico 5°CCarico 100% 75% 50% 25%Temp. aria esterna 35°C 26,7°C 18,3°C 12,8°C

Energy indices ESEER and IPLVIncreasingly closer attention is being paid towards thepower consumption of air-conditioning equipment, both inEurope and elsewhere.For many years in the United States, reference has notjust been made to efficiency at rated conditions. A valua-tion index is also used which considers marginal opera-tion of the unit at rated conditions as well as increasedusage in part load conditions when the external air tempe-rature is lower than the rated value and when the separa-tion stages of the cooling compressors are used.The valuation index adopted in the United States is calledIPLV (Integrated Part Load Value) and is defined in theregulations issued by ARI (American Refrigeration Institu-te).

where EER100%, EER75%, EER50% and EER25% are the effi-ciencies of the chiller in the various load conditions (100%- 75% - 50% and 25% respectively), calculated in the ex-ternal air temperature conditions shown below.The temperature of the water leaving the evaporator isconsidered constant at 6.7°C in all load conditions, with adelta of 5°C in the full load condition.The multipliers 1, 42, 45 e 12 are the cooling performancecoefficients in various load conditions statistically calcula-ted by ARI an the basis of surveys conducted, for varioustypes of buildings and operating conditions, in 29 Ameri-can cities.

Evaporator temp. leaving 6,7°C costanteDeltaT full load 5°CLoad 100% 75% 50% 25%External air temp. 35°C 26,7°C 18,3°C 12,8°C

Page 5: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

III B100HL_105_110D_CV_03_07_IT_GB

In Europa esiste una proposta EECCAC (Energy Efficien-cy and Certification of Central Air Conditioner)

Acqua uscita evaporatore 6,7°CDeltaT a pieno carico 5°CCarico 100% 75% 50% 25%Temp.aria esterna 35°C 30°C 25°C 20°C

Utilizzo degli Indici EnergeticiDopo aver stabilito quale indice utilizzare e stimata l’ener-gia totale richiesta dall’impianto nella gestione estiva (inkWh), si possono dedurre i consumi di energia elettricastagionale (in kWh), con la seguente formula:

Energia assorbita = Energia richiesta / Indice di efficienza

Il calcolo energetico reale può essere ottenuto, più corret-tamente, in forma “dinamica”, considerando cioè la curvadell’andamento del carico al variare della temperaturaesterna, la località ed il monte-ore di riferimento.Con questi dati ogni consulente o progettista di impianti,potrà fare le proprie valutazioni in funzione del tipo di edi-ficio, del luogo di installazione, del tipo di carico termicoed altro. Può inoltre determinare l’indice energetico con ilmetodo che meglio rispecchia le esigenze dell’impianto epuò affrontare confronti energetici tra sistemi simili o equi-valenti utilizzando la stessa unità di riferimento.

In Europe there is a proposal for EECCAC (Energy Effi-ciency and Certification of Central Air Conditioner)

Evaporator temp. leaving 6,7°CDeltaT full load 5°CLoad 100% 75% 50% 25%External air temp. 35°C 30°C 25°C 20°C

Using the energy indicesAfter establishing which index to use and estimating thetotal power required by the system in the summer mode(in kWh), we can calculate seasonal electricity consump-tion (in kWh) using the following formula:

Power absorbed = Power requested / Index of efficiency

The real power calculation can be obtained more correctlyin a “dynamic” form, that is, considering the load perfor-mance curve at different external temperatures, the loca-tion and the reference number of operating hours.These figures will allow plant consultants and designersto make their evaluations depending on the type of buil-ding, the place of installation and the type of heat load.etc.. They can also determine the energy index using themethod that best reflects plant requirements and can makecomparisons between similar or equivalent systems usingthe same reference unit.

Proposta EECCAC ESEER = (3*EER100% + 33*EER75% + 41*EER50% + 23*EER25%) /100 Proposal EECCAC

NECS-N IPLV ESEER NECS-N IPLV ESEER

0152 B 4,48 4,04 0152 LN 4,58 4,09

0182 B 4,53 4,08 0182 LN 4,66 4,16

0202 B 4,47 4,03 0202 LN 4,51 4,03

0252 B 4,44 4,00 0252 LN 4,50 4,02

0302 B 4,38 3,95 0302 LN 4,57 4,08

0352 B 4,51 4,06 0352 LN 4,44 3,96

0412 B 4,35 3,92 0412 LN 4,41 3,94

0452 B 4,54 4,09 0452 LN 4,40 3,93

0512 B 4,48 4,04 0512 LN 4,47 3,99

0522 B 4,64 4,18 0522 LN 4,45 3,97

0612 B 4,43 3,99 0612 LN 4,21 3,76

Page 6: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

IV B100HL_105_110D_CV_03_07_IT_GB

Smart Defrost (Brevetto Climaveneta)

Smart Defrost sostituisce lo sbrinamento tradizionale perottenere tre fondamentali vantaggi· Riduzione del tempo di sbrinamento· Aumento dell’efficienza globale dell’unità· Minimizzazione dell’abbassamento della temperatura

inviata all’impianto durante lo sbrinamento.Il suo funzionamento si basa sull’implementazione di tredifferenti algoritmi che, interagendo tra loro, con i dati difunzionamento dell’unità e con le condizioni ambientali,permette di personalizzare, ciclo dopo ciclo, lo sbrinamentoin modo da ottimizzare il funzionamento dell’unità edaumentarne l’efficienza globale.

Il primo algoritmo, TIMER TUNING, migliora la stima dellaquantità di ghiaccio sulla batteria, variando il tempo d’iniziosbrinamento.A tempi di sbrinamento reale maggiori, corrisponderà untempo d’inizio sbrinamento inferiore e viceversa. Questafunzione permette di ottenere un significativo aumentodell’energia prodotta, e quindi un aumento del COPintegrato, rispetto all’utilizzo dello sbrinamento tradizionale.

Il secondo algoritmo, TIMER TUNING + AUTO TUNING,interagisce con il primo e introduce un parametro dicontrollo aggiuntivo: la differenza tra la temperatura dievaporazione e quella esterna. Questa logica è moltoimportante soprattutto per aree geografiche molto umide,con temperatura esterna non critica ma un alto tasso diumidità, e quindi veloce formazione di ghiaccio esbrinamenti ravvicinati, oppure per aree geografiche moltofredde ma con bassa umidità, e quindi con poca formazionedi ghiaccio e poca necessità di sbrinare. In ambedue i casilo sbrinamento tradizionale “spreca” notevole energiainutilmente.

Il terzo algoritmo, FREE - DEFROST, controlla se le condizionipermettono uno sbrinamento “naturale” a spese della solaaria esterna e lo effettua durante le pause di funzionamentodei singoli circuiti, senza effettuare l’inversione di ciclo. Graziea questa logica viene risparmiata l’energia termica che laPompa di Calore avrebbe dovuto produrre per compensarel’immissione di acqua fredda all’impianto necessaria duranteil tradizionale sbrinamento ad inversione di ciclo.

Una Pompa dicalore dotata diSmart Defrost,potrà garantire unapotenza termicanetta, comprensivaquindi dellariduzione dovutaagli sbrinamenti,s u p e r i o r emediamente del 5%rispetto l’analogaunità cons b r i n a m e n t otradizionale.

Smart Defrost (Climaveneta Patent)

Smart Defrost replaces traditional defrosting systemsthanks to three fundamental advantages:· Reduction in defrost cycle times· Increase in overall chiller efficiency· Minimisation of the temperature reduction sent to the

system during defrosting.The system is based on the implementation of threedifferent algorithms which interact with each other, withthe chiller operating data and with environmental conditionsin order to personalise defrosting, cycle after cycle, andthus optimise chiller operation and increase overallefficiency.

The first algorithm, TIMER TUNING, improves estimatesof the quantity of ice on the coil, thus varying the initialdefrost time. Longer real defrost times correspond toshorter defrost start times, and vice-versa. This functionachieves significant increases in power production andconsequently increases integrated COP with respect tothe traditional defrost system.

The second algorithm, TIMER TUNING + AUTO TUNING,interacts with the first and introduces an additional controlparameter: the difference between evaporationtemperature and outdoor temperature. This logic is veryimportant, especially in very each humid areas whereoutdoor temperatures are not critical but humidity levelsare very high, thus rapidly forming ice and increasing thefrequency of defrosting cycles, or in very cold areas withlow levels of humidity, thus forming small amount of iceand reducing defrost requirements. In both cases,traditional defrosting “wastes” considerable amounts ofpower.

The third algorithm, FREE - DEFROST, checks whetheroperating conditions allow natural defrosting at the soleexpense of external air and achieves this while individualcircuits are on pause, without performing cycle reversals.This logic saves the heating power that the heat pumpwould have had to generate to offset the introduction of

cold water to thesystem requiredduring traditionaldefrost and cycler e v e r s a loperations.A heat pump fittedwith Smart Defrostoffers a net heatingcapacity, includingthe reduction dueto defrost cycles,therefore, 5%higher than thesame chiller usinga traditional defrostsystem.

Page 7: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

V B100HL_105_110D_CV_03_07_IT_GB

CONTROLLORE con visualizzazione a LEDIn tutte le unità è installato il nuovo controllore “W3000Base”. Per tutte le unità è di-sponibile, come accessorio, ilcontrollore in versione“W3000 Compact” coninterfaccia utente LCD “userfriendly”. Questa interfaccia èdisponibile anche in versioneremotizzabile.

Le funzioni principali: QuickMind, supervisione locale e remota FWS, gestione del dop-pio set-point etc., confermano l’impegno di Climavenetaal continuo sviluppo della propria elettronica. Le pompe dicalore, inoltre, presentano l’originale controllo dellosbrinamento, by Climaveneta, denominato “SbrinamentoAutoadattivo” che riduce sensibilmente i tempi dellosbrinamento migliorando il rendimento energetico dell’uni-tà. Interfacciabilità con i sistemi BMS presenti sulmercato:METASYS®, MODBUS®, LONWORKS®,SIEMENS®, TREND®.

Black Box mantiene 200 eventi-allarme in memoria,stampabili con qualsiasi personal computer.

QuickMind è lo speciale controllo in grado di monitorare iprincipali parametri di funzionamento del sistema, preve-dendo il comportamento dell’impianto per anticipare leregolazioni dell’unità, in modo da ottimizzare costantemen-te le prestazioni; permette di scegliere come parametro diregolazione sia la temperatura di ritorno dall’impianto siaquella di mandata. Il suo utilizzo permette di controllare leoscillazioni della temperatura in uscita dall’unità anche conbassi contenuti d’acqua nell’impianto. Quando, con unitàa due compressori e 12 avv/h-max e con una regolazionedel tipo tradizionale, il contenuto minimo raccomandato èdi 5,5 lt/kW, con il regolatore QuickMind si può garantireun corretto funzionamento della stessa unità anche conun contento d’acqua dell’impianto di soli 2,5 lt/kW, ridu-cendo notevolmente l’oscillazione della temperatura inuscita. Dal grafico riportato qui sopra si può notare checon QuicKMind l’oscillazione in uscita viene valutata di4,3°C, mentre con la regolazione del tipo tradizionale sa-rebbe di 7,54°C,senza peraltro ga-rantire un tempominimo di accen-sione dei com-pressori accettabi-le.

CONTROL UNIT with LED displayThe new “W3000 Base” control unit is installed on all units.

The “W3000 Compact” controlunit, featuring a “user friendly”LCD interface, is available onall units as an accessory item.This interface is also availablein a version with a remote-control feature.

Main functions: QuickMind,local and remote FWS

supervision, dual setpoint management, etc., confirmClimaveneta’s commitment to continually developing itselectronics technology. The heat pumps, moreover, arefitted with the original Climaveneta defrosting controlsystem called “Autotuning Defrost” which considerablyreduces defrosting times, thus improving the energy per-formance of the unit. Interfaces with BMS systems:METASYS®, MODBUS®, LONWORKS®, SIEMENS®,TREND®.

Black Box logs data relative to 200 alarm events whichcan be printed with of personal computer.

QuickMind is a special control unit which monitors themain operating parameters, predicts system behaviour andanticipates unit settings in order to constantly optimiseperformance; it allows both return and delivery watertemperatures to be chosen as adjustment parameters. Itcan reduce outlet temperature fluctuations even with asmall amount of water in the system. When, for dual-compressor chillers featuring a maximum of 12 start-upsper hour and using a traditional adjustment system, theminimum recommended water content is 5.5 l/kW,QuickMind ensures the same chiller operates correctlyeven with a water content of just 2.5 l/kW and considerablyreduces outlet temperature fluctuations. The above graphshows that outlet temperature fluctuations with QuickMindare limited to 4.3°C as opposed to 7.54°C if the traditionaladjustment system were used, without even ensuring anacceptable minimum compressor start time.

Page 8: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

VI B100HL_105_110D_CV_03_07_IT_GB

Gruppo Idronico Integrato (Opzionale).

Unità compatte PLUG and PLAY.NECS è stato progettato per ridurre al minimo il lavoro diinstallazione.Il gruppo idronico integrato racchiude in sé tutti icomponenti idraulici, ottimizzando spazi, tempi e costi diinstallazione.Il gruppo idronico integrato è composto da:- Serbatoio di accumulo- Elettropompa orizzontale centrifuga monoblocco.- Manometro in aspirazione pompa- Flussostato acqua- Valvola di taratura della portata- Valvola di scarico- Sonda temperatura ingresso acqua scambiatore- Sonda temperatura uscita acqua scambiatore- Sfiato aria- Valvola di sicurezza tarata a 3 bar.- Vaso di espansione da 8 o 12 lt, precaricato a 1,5 bar- Valvola di ritegno (solo se presente P2).- Filtro acqua a Y con rete in inox già montato a bordo.

Configurazioni disponibiliGruppo idronico 1 pompaGruppo idronico 2 pompeGruppo idronico 1 pompa con accumuloGruppo idronico 2 pompe con accumulo

Per maggiori dettagli, vedere la sezione B “Gruppo Idronico”

IDRORELAXLa famiglia di refrigeratori e pompe di calore NECS è di-sponibile nella configurazione IR; in tal modo tali unità pos-sono essere abbinate al sistema IDRORELAX, un siste-ma idronico centralizzato in grado di gestire ilraffrescamento, il riscaldamento e la produzione di acquasanitaria, per applicazioni residenzia-li, alberghiere e terziarie. Per ulterio-ri informazioni sul sistemaIDRORELAX si rimanda alla docu-mentazione dedicata.

Integrated Hydronic Unit (Optional).

Compact PLUG and PLAY units.NECS has been designed to reduce installation work to aminimum.The integrated hydronic unit incorporates all the hydrauliccomponents, thus optimising installation space, time and costs.The integrated hydronic unit is composed give:- Storage tank- Horizontal one-piece centrifuge pump.- Pump inlet pressure gauge- Flow switch- Flow control valve- Discharge valve- Exchanger input water temperature probe- Exchanger outlet water temperature probe- Air vent- 3 bar safety valve.- One 8 or 12-litre expansion tanks, pre-pressurised to 1,5

bar- Check valve (only if P2 is fitted)- Pre-mounted Y-shaped water filter with stainless steel

mesch

Available configurationsHydronic group 1 pompHydronic group 2 pompsHydronic group 1 pomp with water tankHydronic group 2 pomps with water tank

For greater information, to see the section B “HydronicGroups”

IDRORELAXThe NECS range of chillers with heat pump is available inthe IR configuration; this allows units to be combined withIDRORELAX, a centralised hydronic system for managingcooling and heating requirements and producing hotrunning water for residential, hotel and office applications.

Further information on theIDRORELAX system can beobtained by consulting the relativedocumentation.

Page 9: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

UNIT DESCRIPTIONNECS-N

DESCRIZIONE UNITA'

NECS. Sistema di ultima generazione NECS. State of the art systemNECS comprende una serie di pompe di calore e refrigeratori, ottimali perimpianti di climatizzazione a bassa e media potenzialità, in particolare idealiper operare in impianti a basso contenuto d'acqua.A distinguere NECS da tutti gli altri sistemi è la sua intelligenza QuickMind,l'esclusivo controllo sviluppato da Climaveneta.Il Sistema NECS grazie all'innovativo controllo QuickMind è stato concepitoper operare in impianti a basso contenuto d'acqua nei quali, a differenza deicontrolli tradizionali, permette di minimizzare le variazioni di temperaturadell'acqua in mandata anche in presenza di carichi fortemente variabili.Costituisce un'alternativa altamente professionale all'installazione di gruppidi accumulo.NECS assicura un preciso controllo della temperatura dell'acqua già apartire da soli 2,5 litri/kW.I tempi tecnici di messa in funzione e a regime sono velocizzati.Nella fase di messa in funzione, si deve solo impostare il set point dellatemperatura.La possibilità d'integrazione del gruppo idronico, all'interno dell'unità,semplifica le attività di installazioni idrauliche ed elettriche del sistema.QuickMind, auto-adatta in modo continuo i parametri di regolazione delsistema alle caratteristiche ed esigenze dell'impianto.

NECS is a new series of heat pumps and water chillers which are ideal forlow-to-medium power air-conditioning systems and particularly suitable forinstallations with a limited water content.NECS is a step beyond other systems thanks to its exclusive QuickMindcontrol system, specifically developed by Climaveneta.Thanks to the innovative QuickMind control, the NECS system has beendesigned to work on plants with a low water content where, unlike traditionalcontrols, it minimises the variations in inlet water temperature even inextremely variable load conditions. It is a highly professional alternative tothe installation of storage tanks.NECS assures a precise water temperature control even at just 2.5litres/kW.Technical start-up and operating times have been reduced.During the start-up phase, just the temperature set point needs setting.The possibility integration of the hydronic-pump-group inside the unitsimplifies the water and electrical power circuits of the system.QuickMind continuously adapts its system settings to the variousrequirements of the plant.

Smart Defrost (Brevetto Climaveneta) Smart Defrost ( Climaveneta Patent)Le pompe di calore sono dotate di un innovativo sistema di sbrinamentoautoadattativo brevettato capace di ottimizzare i tempi di sbrinamentomigliorando l’efficienza totale dell’unità.La forza di questa nuova logica è la capacità di modificare i parametriutilizzati dagli algoritmi ciclo dopo ciclo in modo automatico in funzione dellecondizioni esterne.Tre differenti algoritmi (Timing Defrost, Autotuning Defrost, Free Defrost)controllando la pressione di evaporazione, temperatura aria esterna etempo di sbrinamento permettono un’ottima stima del ghiaccio sulla batteriagarantendo così un efficace ed efficiente ciclo di sbrinamento.

The air to water heat pumps incorporate an innovative auto tuningdefrosting system that is able to optimize the defrosting time withimprovement of the total efficiency.The new logic power is the capacity to modify automatically the parameterscycle by cycle in according to external conditions.Three different algorithms (Timing Defrost, Auto tuning Defrost, FreeDefrost) estimate exactly the quantity of ice inside the coils on the base ofevaporating pressure, defrosting time of the preview cycle and external airtemperature. The new system assure an efficiency and efficacy defrostingcycle.

Pompa di calore aria-acqua Air-to-water heat pumpPompa di calore del tipo aria-acqua ad inversone di ciclo, concommutazione manuale del regime di funzionamento. Unità fornita completadi carica olio incongelabile, carica refrigerante, collaudo e prove difunzionamento in fabbrica e necessita quindi, sul luogo dell'installazione,delle sole connessioni idriche ed elettriche.

Reverse cycle air-to-water heat pump with manual mode switch. The unit issupplied with anti-freeze oil and refrigerant and has been factory tested. On-site installation therefore just involves making connections to the mainspower and water supplies.

Unità caricata con refrigerante ecologico R410A Unit charged with R410A ecological refrigerant.

COMPOSIZIONI UNITA' STANDARD STANDARD UNIT COMPOSITIONStruttura Supporting frameStruttura costituita da un basamento in lamiera d’acciaio zincato a caldo,verniciato con polveri poliesteri e da pannelli portanti in Peraluman. Lastruttura autoportante atta ad assiemare e sostenere i componenti principaliè realizzata in modo da garantire la massima accessibilità per le operazionidi servizio e manutenzione.

Frame comprising a base in polyester-painted hot-galvanised sheet steeland supporting panels in Peraluman. The self-supporting structurecontaining the main components is designed to ensure maximum ease ofaccess during servicing and maintenance operations.

Compressori CompressorsCompressori di tipo ermetico rotativo scroll. Tutti i compressori sonocompleti del riscaldatore del carter, protezione termica elettronica conriarmo manuale centralizzato, motore elettrico a due poli.

Hermetic scroll compressors. All the compressors are fitted with an oil sumpheater, electronic overheating protection with centralised manual reset anda two-pole electric motor.

Scambiatore acqua-refrigerante Water-refrigerant heat exchangerScambiatore a piastre saldobrasate in acciaio AISI 316. Gli scambiatorisono esternamente rivestiti con materassino anticondensa in neoprene acelle chiuse. Quando l’unità non è in funzione sono protetti contro laformazione di ghiaccio all’interno da una resistenza elettrica termostatata,mentre, con unità funzionante, la protezione è assicurata da un pressostatodifferenziale lato acqua. L’unità è inoltre predisposta per funzionare, conmiscele incongelabili, fino ad una temperatura in uscita dallo scambiatore di-8°C.

AISI 316 steel braze-welded plate exchanger. The heat exchangers areinsulated with a closed-cell condensation proof lining in neoprene. Athermostatically controlled electric heater prevents ice from forming insidethe evaporator when the unit is not working. When the unit is working, it isprotected by a differential pressure switch mounted on the water side. Theunit can work with antifreeze mixtures at exchanger outlet temperatures aslow as -8°C.

Filtro meccanico lato acqua Water side filterFiltro a "Y" progettato e costruito per poter intercettare le impurità presentinel circuito idraulico. E' dotato di cartuccia a rete con maglia inox e foripassaggio 0,9 mm, sostituibile senza rimuovere il corpo valvola dallatubazione.

"Y" type filter designed and built to retain impurities in the hydraulic circuit. Itfeatures a stainless steel mesh cartridge with 0.9mm holes which can bereplaced easily without removing the valve from the piping.

Scambiatore refrigerante-aria Refrigerant-air heat exchangerScambiatore a pacco alettato realizzato con tubi in rame e alette in alluminioadeguatamente spaziate in modo da garantire il miglior rendimento nelloscambio termico.

Finned coil exchanger made from copper tubes and aluminium fins. Thealuminium fins are correctly spaced to guarantee optimum heat exchangeefficiency.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB1ELCAdoc 20/03/2006

Page 10: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

UNIT DESCRIPTIONNECS-N

DESCRIZIONE UNITA'

Ventilatori FansElettroventilatori assiali con grado di protezione IP 44, a rotore esterno, conpale in lamiera stampata, alloggiati in boccagli a profilo aerodinamico,completi di rete di protezione antinfortunistica. Motore elettrico a 6 poliprovvisto di protezione termica incorporata. Il vano di ventilazione è diviso indue zone.Questa soluzione consente di migliorare l'efficienza ai carichiparziali, potendo fermare i ventilatori del circuito non funzionante.

Axial electric fans, protected to IP 44, with external rotor and pressed sheetmetal blades. Housed in aerodynamic hoods complete with safety grille. 6-pole electric motor with built-in thermal protection. The fan chamber isdivided into two sections. This improves efficiency with partial loads as thefans of the idle circuit can be stopped.

Circuito frigorifero Refrigerant circuitPrincipali componenti del circuito frigorifero:- filtro deidratore,- indicatore passaggio liquido con segnalazione presenza umidità,- valvola termostatica con equalizzatore esterno,- valvola di sicurezza alta pressione,- pressostati sicurezza alta e bassa pressione,- ricevitore e separatore di liquido- valvola d'inversione di ciclo a 4 vie

Main components of the refrigerant circuit:- dryer filter,- refrigerant line sight glass with humidity indicator,- externally equalised thermostatic valve,- high pressure safety valve,- high and low pressure switches,- liquid receiver and separator,- 4-way reverse cycle valve.

Quadro elettrico di potenza e controllo Electric power and control panelQuadro elettrico di potenza e controllo, costruito in conformità alle normeEN 60204-1/IEC 204-1, completo di :- trasformatore per il circuito di comando,- sezionatore generale bloccoporta,- interruttori magnetotermici per compressori e ventilatori,- morsetti per blocco cumulativo allarmi (BCA),- morsetti per ON/OFF remoto,- morsettiere dei circuiti di comando del tipo a molla,- quadro elettrico per esterno, con doppia porta e guarnizioni,- controllore elettronico.- Cavi numerati circuito comando- Relè consenso comando pompa- Regolazione continua della velocità dei ventilatori

Electric power and control panel, built to EN 60204-1/EC 204-1 standards,complete with:- control circuit transformer,- general door lock isolator,- automatic circuit breakers for compressors and fans,- terminals for cumulative alarm block (BCA),- remote ON/OFF terminals,- spring-type control circuit terminal board,- electric panel with double door and seals for outdoor installation,- electronic controller.- Control circuit numbered wires- Pump control consent relay- Fan speed continuous regulation

Controllore Elettronico Electronic controlW3000 è lo speciale controllo in grado di monitorare i principali parametri difunzionamento del sistema, prevedendo il comportamento dell'impianto peranticipare le regolazioni dell'unità, in modo da ottimizzarne costantemente leprestazioni.- ottimizza la messa a regine dell'impianto- minimizza le oscillazioni della temperatura di mandata al set-poitimpostato.- permette di scegliere come parametro di regolazione sia la temperatura diritorno dall'impianto, sia su quella di mandata- ottimizza l'inserimento dei compressori in presenza di carichi ridotti- mantiene 200 eventi-allarme in memoria, stampabili con un qualsiasipersonal computer.- rileva e notifica un'ampia serie di eventi tra cui: insufficiente contenutod'acqua; portata d'acqua nell'impianto fuori limiti; temperatura fuori limiti;scadenza interventi di manutenzione su pompe e compressori; allarmeintegrità circuito frigorifero.

Inoltre, W3000 è predisposto per: interfacciabilità con i sistemi BMS e con ilSoftware di Supervisione Climaveneta; controllo remoto dell'unità tramitemodem; controllo tramite tastiera remota.

Disponibilità di un Kit Tastiera Remota per unità già installate. Comprenden° 2 tastiere ad "LCD" solo per unità già assemblate senza predisposizioneTastiera Remota

W3000 is a special control which monitors the main operating parametersof the system, predicts the behaviour of the plant and anticipates the unitssettings in order to constantly optimise its performance.- optimises plant operation- minimises discharge line temperature oscillations compared with the setpoint- allows either return or delivery water temperatures to be set as adjustmentparameters.- optimises compressor operation in the event of reduced loads- stores 200 alarm events; these can be downloaded to any personalcomputer.- detects and reports a large series of events such as: insufficient watercontent in the plant; low/high water flow in the plant; low/high inlet watertemperature; pump and compressor maintenance times; refrigerant circuitintegrity alarm.

W3000 is also suitable for: interface connection with BMS systems;interface connection with the Climaveneta Supervision Software; remotecontrol of the unit by modem (fixed/GSM); control from a remote keyboard.

Availabilities of kit a Remore Keyboard for unit already installed. It onlycomprises n° 2 keyboard for unit assembled without predisposition RemoreKeyboard

Modello base Basic modelUnità senza recupero di calore. Unit without heat recovery.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB2ELCAdoc 20/03/2006

Page 11: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

UNIT DESCRIPTIONNECS-N

DESCRIZIONE UNITA'

Modello con recupero parziale (D) Model with partial heat recovery (D)Pompa di calore aria-acqua ad inversione di ciclo dotata didesurriscaldatore. Questa versione, come l’unità base, prevede laproduzione d’acqua calda o acqua refrigerata, secondo la commutazionestagionale selezionata, nel circuito primario. In questa versione è aggiunto,rispetto alla versione base, uno scambiatore di calore acqua/freon, sullalinea di mandata del gas. Tale scambiatore, posto in serie al condensatoredel circuito frigorifero tradizionale, è opportunamente dimensionato daconsentire il recupero del solo calore di desurriscaldamento per laproduzione d’acqua calda a temperatura medio elevata (circuito secondarioo di recupero). La produzione d’acqua calda nel circuito di recupero èdisponibile sia d’estate sia d’inverno, per uso sanitario od altro, con unapotenza pari, in prima approssimazione, alla potenza assorbita dalcompressore. Dopo l’attraversamento di questo scambiatore, il gasrefrigerante entra nel condensatore (scambiatore refrigerante-aria d’estate erefrigerante-acqua d’inverno) dove è completata la condensazione. Sidistinguono due cicli di funzionamento:

FUNZIONAMENTO INVERNALELo scambiatore cui è collegato il circuito idraulico principale funziona comecondensatore (lo scambiatore refrigerante-aria funziona come evaporatore).Lo scambiatore refrigerante-acqua dedicato al recupero parziale di calore(desurriscaldatore) permette di produrre acqua calda in un secondo circuitoidraulico dedicato, ad esempio, alla produzione di acqua calda per usosanitario od altro.

FUNZIONAMENTO ESTIVOLo scambiatore cui è collegato il circuito idraulico principale funziona comeevaporatore (lo scambiatore refrigerante-aria funziona come condensatore).Lo scambiatore refrigerante-acqua dedicato al recupero parziale di calore(desurriscaldatore) permette la produzione di acqua calda come avviene nelfunzionamento invernale.

Reverse cycle air-water heat pump fitted with a desuperheater. Similarly tothe basic unit, this version produces hot or chilled water in the primarycircuit, depending on which seasonal mode has been selected. Comparedwith the basic configuration, this version features a water/freon heatexchanger on the gas delivery line. This heat exchanger, fitted in series withthe traditional cooling circuit condenser, is large enough to recover justdesuperheating heat for the production of medium-to-high temperaturewater (secondary or recovery circuit). Hot water can be produced in therecovery circuit for domestic hot water and the like both in summer andwinter. The heating capacity of this circuit is approximately equal to thepower input of the compressor. After going through this exchanger, therefrigerant gas enters the condenser (refrigerant-air exchanger in summerand refrigerant-water exchanger in winter) where condensation iscompleted. There are two operating cycles:

WINTER MODEThe exchanger to which the main water circuit is connected works as acondenser (the refrigerant-air exchanger works like an evaporator). Therefrigerant-water exchanger for partial heat recovery (desuperheater) allowshot water to be produced in a second hydraulic circuit for domestic hotwater and the like.

SUMMER MODEThe exchanger to which the main water circuit is connected works as anevaporator (the refrigerant-air exchanger works like a condenser). Therefrigerant-water exchanger for partial heat recovery (desuperheater) allowshot water to be produced in the same way as the winter mode.

VERSIONI DISPONIBILI AVAILABLE VERSIONSB (Base) B (base)Unità standard. Standard unit.

LN (Silenziata) LN (Low Noise)Versione silenziata. Questa configurazione prevede un isolamento acusticodedicato per il vano compressori e una riduzione del numero di giri deiventilatori. La velocità di rotazione viene comunque automaticamenteaumentata, qualora le condizioni ambientali siano particolarmente gravose.

Low noise version. This configuration features special soundproofing for thecompressor chamber and reduced fan speed. Fan speed is automaticallyincreased if environmental conditions are particularly tough.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB3ELCAdoc 20/03/2006

Page 12: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

DESCRIZIONE UNITA' UNIT DESCRIPTIONNECS-N

Accessori AccessoriesRivestimento insonorizzante Noise insulationAntivibranti in gomma Rubber isolatorsKit LT per basse temperature di aria esterna. Vedi pag. "Limiti operativi" Kit LT for low ambient temperature. Refer to page "Operating range"

Rubinetto mandata compressori Compressor discharge valveRubinetto aspirazione compressore Compressor suction valveBatterie in rame/rame -Cu/Cu Cu/Cu condensing coilsBatterie con alette preverniciate Condensing coils with epoxy-coated finsBatterie con trattamento "Fin Guard Silver" Condensing coils with Fin Guard Silver treatmentProtezione batterie con rete elettrosaldata. Coil protection with wire net.Flussostato acqua evaporatore (fornito separatamente) Evaporator water flow switch (supplied separately)Contatti puliti per segnalazione funz. Compressori Free voltage contacts for compr. operation signallingControllo sequenza fasi da esterno Remote control phase sequenceManometri AP e BP HP and LP gaugesTastiera W3000 Compact W3000 Compact KeyboardTastiera Remota (solo con tastiera W3000 Compact) Remote keyboard (only with keyboard W3000 Compact)Kit pompe con o senza accumulo Water pump kit with or without storage tankAccumulo ausiliario GA Storage tank auxsiliary GAResistenza antigelo su serbatoio accumulo (se presente) Water tank anti-freeze heater (if fitted)

HFC R410AB100HL_105_110D_CV_03_07_IT_GB4ELCAdoc 20/03/2006

Page 13: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

NECS-NDESCRIZIONE UNITA' UNIT DESCRIPTION

Electronic control featuresCaratteristiche controlli elettronici

MicroprocessorMicroprocessoreNECS-N NECS-ND 0152 - 0612

W3000 W3000 BaseMulti-language menuMenù multilingua OPT

Phase sequency relayControllo sequenza fasi OPT

Cumulative fault alarmSegnalazione blocco cumulativo guasti X

Evaporator inlet/outlet water temperature displayVisualizzazione temperatura acqua ingresso/uscita evaporatore X

General unit alarms displayVisualizzazione allarmi generali di macchina X

External air temperature displayVisualizzazione temperatura aria esterna X

Steps inlet water proportional + integral temperature adjustmentRegolazione temperatura ingresso, proporzionale a gradini + integrale X

Steps inlet water proportional temperature adjiustmentRegolazione proporzionale a gradini sulla temperatura in ingresso. X

Quick Mind outlet adjustmentRegolazione Quick Mind in uscita X

Compressors hour rotation + FIFORotazione oraria + FIFO dei compressori X

Starting compressors sequency controlControllo sequenza avviamento compressori X

Continuous fan speed regulation for outdoor sectionRegolazione continua della velocità dei ventilatori esterni X

Demand LimitDemand Limit OPT

Autotuning defrost Smart DefrostSbrinamento autoadattivo Smart Defrost X

Remote keyboardPredisposizione per tastiera remota X

Connection to sequencierCollegamento a sequenziatore X

Local/Remote supervision through browser and FWSSupervisione locale/remota mediante browser e FWS OPT

Manager 3000 connectionCollegamento con Manager 3000 OPT

Modbus communication protocolInterfacciabilità con protocollo Modbus OPT

Bacnet communication protocolInterfacciabilità con protocollo Bacnet OPT

Interface connection to LonWorks networkInterfacciabilità con rete LonWorks OPT

Relay manage pumpRelè comando pompa X

Control hydronic kit with 1 pumpGestione gruppo di pompaggio con una pompa OPT

Control hydronic kit with 2 pumpsGestione gruppo di pompaggio con due pompe OPT

Plant pressure controlControllo impianto in pressione OPT

Remote on/off with external volt-free contactOn/off remoto con contatto esterno privo di tensione X

Summer/winter switching from external contactCommutazione estate/inverno da contatto esterno X

Set-point by 0+10V external contact compensationVariazione set-point da segnale 0-10V esterno OPT

Set-point compensation based on outdoor air temperatureLimitazione del set-point in funzione della temp. aria esterna X

X Fornito di serieOPT Disponibile su richiestapar. Attivabile modificando uno dei valori dei parametri diconfigurazione

X StandardOPT Available on requestpar. Available modifying a value of the configuration parameters

HFC R410AB100HL_105_110D_CV_03_07_IT_GB5ELCAdoc 20/03/2006

Page 14: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

GENERAL TECHNICAL DATABDATI TECNICI GENERALINECS-N

0152 041203520302025202020182SIZEGRANDEZZA

(1)NECS-N

kW

kW

Total power input (unit)

Cooling capacity

36 32 14 20 28 19 16 34 31 27 19 18 15 13

48 43 38 94 82 72 58

Potenza assorbita totale (unità)

Potenza frigoriferaPotenza assorbita compressori kWCompressor power input

Portata acqua scambiatorePerdite di carico scambiatore

6 7 8 10 12 14 16 57 42 42 51 53 57 47

Exchanger water flowExchanger water pressure drop

m³/hkPa

Base Base Base Base Base Base BaseElectronicControlControllore Elettronico W3000

Heating capacity 93 81 65 54 48 43 105Potenza termica 32 28 25 20 17 15 13

Total power input (unit) 34 30 26 21 18 16 14Potenza assorbita totale (unità)Exchanger water flow 18 16 14 11 9 8 7Portata acqua scambiatoreExchanger water pressure drop 73 69 66 55 54 61 75Perdite di carico scambiatore

NECS-NkW

kWm³/hkPa

(2)

Potenza assorbita compressori Compressor power input kW

kWCompressor power inputPotenza assorbita compressori

(1) (5)

kPa

kPam³/h

m³/hkWkW

kWNECS-ND

Desuperheater water pressure dropDesuperheater water flowEvaporator water pressure dropEvaporator water flowDesuperheater thermal capacityTotal power input (unit)

Cooling capacity

24 20 15 15 14 9 7 5 5 4 3 3 2 2

61 57 55 45 51 61 45 17 15 13 10 8 7 9 30 27 24 17 13 11 16 35 31 27 20 15 13 19 33 29 26 18 14 12 18 97 86 75 60 50 44 39

Perdite di carico desurriscaldatorePortata acqua desurriscaldatorePerdite di carico evaporatorePortata acqua evaporatorePotenza termica al desurriscaldatorePotenza assorbita totale (unità)

Potenza frigorifera

W3000 BaseBaseBaseBaseBaseBaseBaseElectronicControlControllore Elettronico

VentilatoriNumero ventilatoriPortata aria

4 4 6 6 6 4 5,2 5,2 5,2 7,7 7,7 7,5 10,4

8FansNumber of fansAir flow

nm³/s

STD+OPT

CompressoriNumero compressoriNumero circuitiGradini di capacità (unità)

2 2 2 2 2 2 2 1 1 1 1 1 1 1

2 2 2 22 2 2

CompressorsNumber of compressorsNumber of circuitsCapacity steps (unit)

nnn

CaricaRefrigeranteOlio

198,7 9 9,4 12,9 13,3 18,2 7 7 7 8 9 9 5

ChargeRefrigerantOil

KgKg

Peso in funzionamento 400 420 500 630 690 410 770Operating weight Kg

Potenza sonoraPressione sonora

86 84 84 84 84 86 85 55 57 57 56 55 55 55

Sound power levelSound pressure level

dB(A)dB(A)(3)

(4)

(1) Acqua evaporatore (in/out) 12/7 °C Aria condensatore (in) 35 °C(2) Acqua condensatore (in/out) 40/45 °C Aria evaporatore (in) 7 °C R.H. 87%(3) Ad 10 metri (vedi sezione "Livelli sonori a pieno carico")(4) Secondo Eurovent (vedi sezione "Livelli sonori a pieno carico")(5) Acqua desurriscaldatore (in/out) 40/45 °C

(1) Chilled water (in/out) 12/7 °C Condenser air (in) 35 °C(2) Condenser water (in/out) 40/45 °C Chilled air (in) 7 °C U.R. 87%(3) At 10 metre (see "Full load sound level" section)(4) According to Eurovent (see "Full load sound level" section)(5) Desuperheater water (in/out) 40/45 °C

HFC R410AB100HL_105_110D_CV_03_07_IT_GB6ELCAdoc 20/03/2006

Page 15: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

GENERAL TECHNICAL DATABDATI TECNICI GENERALINECS-N

0452 061205520512SIZEGRANDEZZA

(1)NECS-N

kW

kW

Total power input (unit)

Cooling capacity

40 59 50 44 56 48 41 38

138 120 107 151

Potenza assorbita totale (unità)

Potenza frigoriferaPotenza assorbita compressori kWCompressor power input

Portata acqua scambiatorePerdite di carico scambiatore

18 21 24 26 54 70 73 59

Exchanger water flowExchanger water pressure drop

m³/hkPa

Base Base Base BaseElectronicControlControllore Elettronico W3000

Heating capacity 173 157 136 121Potenza termica 52 46 40 36

Total power input (unit) 54 48 42 38Potenza assorbita totale (unità)Exchanger water flow 30 27 24 21Portata acqua scambiatoreExchanger water pressure drop 98 92 76 71Perdite di carico scambiatore

NECS-NkW

kWm³/hkPa

(2)

Potenza assorbita compressori Compressor power input kW

kWCompressor power inputPotenza assorbita compressori

(1) (5)

kPa

kPam³/h

m³/hkWkW

kWNECS-ND

Desuperheater water pressure dropDesuperheater water flowEvaporator water pressure dropEvaporator water flowDesuperheater thermal capacityTotal power input (unit)

Cooling capacity

32 23 25 21 9 7 6 6

79 63 58 75 27 21 19 25 50 37 34 43 57 43 39 49 54 40 37 46

156 143 125 111

Perdite di carico desurriscaldatorePortata acqua desurriscaldatorePerdite di carico evaporatorePortata acqua evaporatorePotenza termica al desurriscaldatorePotenza assorbita totale (unità)

Potenza frigorifera

W3000 BaseBaseBaseBaseElectronicControlControllore Elettronico

VentilatoriNumero ventilatoriPortata aria

10 10 10 8 10,1 13,3 13,0 13,0

FansNumber of fansAir flow

nm³/s

STD+OPT

CompressoriNumero compressoriNumero circuitiGradini di capacità (unità)

2 2 2 2 1 1 1 1

22 2 2

CompressorsNumber of compressorsNumber of circuitsCapacity steps (unit)

nnn

CaricaRefrigeranteOlio

19,5 28,5 35,8 36,5 14 13 13 12

ChargeRefrigerantOil

KgKg

Peso in funzionamento 850 1020 1030 950Operating weight Kg

Potenza sonoraPressione sonora

86 87 87 87 57 58 58 58

Sound power levelSound pressure level

dB(A)dB(A)(3)

(4)

(1) Acqua evaporatore (in/out) 12/7 °C Aria condensatore (in) 35 °C(2) Acqua condensatore (in/out) 40/45 °C Aria evaporatore (in) 7 °C R.H. 87%(3) Ad 10 metri (vedi sezione "Livelli sonori a pieno carico")(4) Secondo Eurovent (vedi sezione "Livelli sonori a pieno carico")(5) Acqua desurriscaldatore (in/out) 40/45 °C

(1) Chilled water (in/out) 12/7 °C Condenser air (in) 35 °C(2) Condenser water (in/out) 40/45 °C Chilled air (in) 7 °C U.R. 87%(3) At 10 metre (see "Full load sound level" section)(4) According to Eurovent (see "Full load sound level" section)(5) Desuperheater water (in/out) 40/45 °C

HFC R410AB100HL_105_110D_CV_03_07_IT_GB7ELCAdoc 20/03/2006

Page 16: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

GENERAL TECHNICAL DATALNDATI TECNICI GENERALINECS-N

0152 041203520302025202020182SIZEGRANDEZZA

(1)NECS-N

kW

kW

Total power input (unit)

Cooling capacity

36 32 14 21 27 19 16 34 30 26 20 18 15 14

48 42 36 94 84 73 55

Potenza assorbita totale (unità)

Potenza frigoriferaPotenza assorbita compressori kWCompressor power input

Portata acqua scambiatorePerdite di carico scambiatore

6 7 8 9 13 14 16 51 42 38 53 54 57 44

Exchanger water flowExchanger water pressure drop

m³/hkPa

Base Base Base Base Base Base BaseElectronicControlControllore Elettronico W3000

Heating capacity 96 84 64 54 48 42 109Potenza termica 32 28 25 20 17 15 13

Total power input (unit) 34 30 26 21 18 15 14Potenza assorbita totale (unità)Exchanger water flow 19 17 15 11 9 8 7Portata acqua scambiatoreExchanger water pressure drop 78 73 71 52 54 61 71Perdite di carico scambiatore

NECS-NkW

kWm³/hkPa

(2)

Potenza assorbita compressori Compressor power input kW

kWCompressor power inputPotenza assorbita compressori

(1) (5)

kPa

kPam³/h

m³/hkWkW

kWNECS-ND

Desuperheater water pressure dropDesuperheater water flowEvaporator water pressure dropEvaporator water flowDesuperheater thermal capacityTotal power input (unit)

Cooling capacity

24 19 14 18 14 10 8 5 5 4 3 3 2 2

61 58 57 41 48 55 45 17 15 13 10 7 6 9 30 27 23 18 14 12 16 35 31 26 21 15 14 18 33 29 25 20 15 13 17 97 87 76 57 50 43 37

Perdite di carico desurriscaldatorePortata acqua desurriscaldatorePerdite di carico evaporatorePortata acqua evaporatorePotenza termica al desurriscaldatorePotenza assorbita totale (unità)

Potenza frigorifera

W3000 BaseBaseBaseBaseBaseBaseBaseElectronicControlControllore Elettronico

VentilatoriNumero ventilatoriPortata aria

4 6 6 8 8 4 3,9 3,7 6,1 5,8 7,9 8,9 8,7

8FansNumber of fansAir flow

nm³/s

STD+OPT

CompressoriNumero compressoriNumero circuitiGradini di capacità (unità)

2 2 2 2 2 2 2 1 1 1 1 1 1 1

2 2 2 22 2 2

CompressorsNumber of compressorsNumber of circuitsCapacity steps (unit)

nnn

CaricaRefrigeranteOlio

28,58,7 9 9,4 12,9 18 20,2 7 7 7 8 9 9 5

ChargeRefrigerantOil

KgKg

Peso in funzionamento 400 460 500 710 770 420 830Operating weight Kg

Potenza sonoraPressione sonora

83 79 79 80 80 83 81 50 54 54 52 51 51 50

Sound power levelSound pressure level

dB(A)dB(A)(3)

(4)

(1) Acqua evaporatore (in/out) 12/7 °C Aria condensatore (in) 35 °C(2) Acqua condensatore (in/out) 40/45 °C Aria evaporatore (in) 7 °C R.H. 87%(3) Ad 10 metri (vedi sezione "Livelli sonori a pieno carico")(4) Secondo Eurovent (vedi sezione "Livelli sonori a pieno carico")(5) Acqua desurriscaldatore (in/out) 40/45 °C

(1) Chilled water (in/out) 12/7 °C Condenser air (in) 35 °C(2) Condenser water (in/out) 40/45 °C Chilled air (in) 7 °C U.R. 87%(3) At 10 metre (see "Full load sound level" section)(4) According to Eurovent (see "Full load sound level" section)(5) Desuperheater water (in/out) 40/45 °C

HFC R410AB100HL_105_110D_CV_03_07_IT_GB8ELCAdoc 20/03/2006

Page 17: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

GENERAL TECHNICAL DATALNDATI TECNICI GENERALINECS-N

0452 061205520512SIZEGRANDEZZA

(1)NECS-N

kW

kW

Total power input (unit)

Cooling capacity

42 63 53 45 60 51 42 40

132 119 103 143

Potenza assorbita totale (unità)

Potenza frigoriferaPotenza assorbita compressori kWCompressor power input

Portata acqua scambiatorePerdite di carico scambiatore

18 20 23 25 51 64 66 57

Exchanger water flowExchanger water pressure drop

m³/hkPa

Base Base Base BaseElectronicControlControllore Elettronico W3000

Heating capacity 169 154 137 121Potenza termica 52 46 40 36

Total power input (unit) 54 48 42 38Potenza assorbita totale (unità)Exchanger water flow 29 27 24 21Portata acqua scambiatoreExchanger water pressure drop 94 89 78 71Perdite di carico scambiatore

NECS-NkW

kWm³/hkPa

(2)

Potenza assorbita compressori Compressor power input kW

kWCompressor power inputPotenza assorbita compressori

(1) (5)

kPa

kPam³/h

m³/hkWkW

kWNECS-ND

Desuperheater water pressure dropDesuperheater water flowEvaporator water pressure dropEvaporator water flowDesuperheater thermal capacityTotal power input (unit)

Cooling capacity

36 26 26 23 9 8 7 6

71 62 55 69 26 21 18 24 54 38 35 45 61 43 40 52 58 41 38 49

148 137 123 107

Perdite di carico desurriscaldatorePortata acqua desurriscaldatorePerdite di carico evaporatorePortata acqua evaporatorePotenza termica al desurriscaldatorePotenza assorbita totale (unità)

Potenza frigorifera

W3000 BaseBaseBaseBaseElectronicControlControllore Elettronico

VentilatoriNumero ventilatoriPortata aria

10 10 10 8 8,7 10,9 10,9 10,9

FansNumber of fansAir flow

nm³/s

STD+OPT

CompressoriNumero compressoriNumero circuitiGradini di capacità (unità)

2 2 2 2 1 1 1 1

22 2 2

CompressorsNumber of compressorsNumber of circuitsCapacity steps (unit)

nnn

CaricaRefrigeranteOlio

29 33,3 35,8 36,5 14 13 13 12

ChargeRefrigerantOil

KgKg

Peso in funzionamento 880 1020 1030 990Operating weight Kg

Potenza sonoraPressione sonora

83 84 84 84 54 55 55 55

Sound power levelSound pressure level

dB(A)dB(A)(3)

(4)

(1) Acqua evaporatore (in/out) 12/7 °C Aria condensatore (in) 35 °C(2) Acqua condensatore (in/out) 40/45 °C Aria evaporatore (in) 7 °C R.H. 87%(3) Ad 10 metri (vedi sezione "Livelli sonori a pieno carico")(4) Secondo Eurovent (vedi sezione "Livelli sonori a pieno carico")(5) Acqua desurriscaldatore (in/out) 40/45 °C

(1) Chilled water (in/out) 12/7 °C Condenser air (in) 35 °C(2) Condenser water (in/out) 40/45 °C Chilled air (in) 7 °C U.R. 87%(3) At 10 metre (see "Full load sound level" section)(4) According to Eurovent (see "Full load sound level" section)(5) Desuperheater water (in/out) 40/45 °C

HFC R410AB100HL_105_110D_CV_03_07_IT_GB9ELCAdoc 20/03/2006

Page 18: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B COOLING CAPACITY PERFORMANCEPRESTAZIONI IN REFRIGERAZIONE NECS-N

01524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 41,4 40,4 38,8 36,0 34,843,640,2 39,2 37,7 35,0 33,842,432,833,936,638,039,041,1Pa 11,3 11,8 12,7 14,2 14,810,111,2 11,7 12,6 14,1 14,710,014,714,012,511,611,19,9Pat 12,3 12,8 13,7 15,2 15,811,112,2 12,7 13,6 15,1 15,711,015,715,013,512,612,110,9Qev 7,1 7,0 6,7 6,2 6,07,56,9 6,7 6,5 6,0 5,87,35,65,86,36,56,77,1Dpev 68,2 65,0 60,1 51,7 48,375,964,3 61,3 56,6 48,7 45,571,642,845,853,357,660,567,5

9,0Tev 11,010,0Pf 44,9 43,9 42,2 39,1 37,847,343,7 42,7 41,1 38,1 36,846,135,837,039,941,542,544,9Pa 11,6 12,1 12,9 14,4 15,110,311,5 12,0 12,9 14,4 15,010,314,914,312,811,911,410,2Pat 12,6 13,1 13,9 15,4 16,111,312,5 13,0 13,9 15,4 16,011,315,915,313,812,912,411,2Qev 7,7 7,6 7,3 6,7 6,58,27,5 7,4 7,1 6,6 6,37,96,26,46,97,27,37,7Dpev 80,6 76,9 71,1 61,1 57,089,576,4 72,8 67,3 57,9 54,184,851,254,863,768,972,280,3

01824225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 46,7 45,7 44,0 41,3 40,149,445,5 44,4 42,8 40,0 38,948,037,738,841,643,244,246,7Pa 13,4 13,9 14,8 16,4 17,012,013,2 13,8 14,7 16,2 16,911,916,716,114,513,613,111,7Pat 14,4 14,9 15,8 17,4 18,013,014,2 14,8 15,7 17,2 17,912,917,717,115,514,614,112,7Qev 8,0 7,9 7,6 7,1 6,98,57,8 7,6 7,4 6,9 6,78,36,56,77,27,47,68,0Dpev 56,3 53,7 50,0 43,9 41,562,753,2 50,8 47,2 41,3 39,059,436,538,744,447,950,356,2

9,0Tev 11,010,0Pf 50,5 49,4 47,8 45,0 43,953,249,3 48,2 46,5 43,8 42,752,041,442,545,346,948,050,7Pa 13,8 14,3 15,2 16,8 17,512,413,6 14,2 15,1 16,7 17,312,317,216,514,914,113,512,1Pat 14,8 15,3 16,2 17,8 18,513,414,6 15,2 16,1 17,7 18,313,318,217,515,915,114,513,1Qev 8,7 8,5 8,2 7,8 7,69,28,5 8,3 8,0 7,5 7,39,07,17,37,88,18,38,7Dpev 65,8 63,0 58,8 52,3 49,773,162,5 59,8 55,8 49,4 46,969,644,246,652,856,759,466,1

02024225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 53,0 51,5 49,2 45,1 43,356,451,5 50,1 47,9 43,8 42,154,840,842,546,548,750,153,3Pa 16,4 17,2 18,3 20,4 21,314,716,3 17,0 18,2 20,2 21,114,520,920,018,016,816,114,4Pat 17,4 18,2 19,3 21,4 22,315,717,3 18,0 19,2 21,2 22,115,521,921,019,017,817,115,4Qev 9,1 8,9 8,5 7,8 7,59,78,9 8,6 8,2 7,5 7,29,47,07,38,08,48,69,2Dpev 51,2 48,4 44,2 37,0 34,157,948,4 45,7 41,7 34,9 32,254,730,432,939,343,145,651,7

9,0Tev 11,010,0Pf 57,3 55,8 53,3 48,9 -60,955,9 54,4 51,9 47,6 45,759,444,546,350,652,954,457,9Pa 16,9 17,7 18,8 20,9 -15,116,7 17,5 18,7 20,8 21,615,021,520,618,517,316,614,8Pat 17,9 18,7 19,8 21,9 -16,117,7 18,5 19,7 21,8 22,616,022,521,619,518,317,615,8Qev 9,9 9,6 9,2 8,4 -10,59,6 9,4 8,9 8,2 7,910,27,78,08,79,19,410,0Dpev 59,9 56,7 51,8 43,5 -67,756,9 53,9 49,2 41,3 38,164,336,139,146,751,154,061,1

02524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 63,0 61,5 59,2 54,9 53,166,461,2 59,8 57,5 53,4 51,764,550,251,955,858,059,462,6Pa 17,1 17,9 19,0 21,1 22,015,417,0 17,7 18,9 21,0 21,915,321,820,918,817,616,815,1Pat 18,6 19,4 20,5 22,6 23,516,918,5 19,2 20,4 22,5 23,416,823,322,420,319,118,316,6Qev 10,8 10,6 10,2 9,5 9,111,410,5 10,3 9,9 9,2 8,911,18,68,99,610,010,210,8Dpev 50,1 47,8 44,2 38,1 35,655,647,2 45,0 41,7 36,0 33,752,431,833,939,342,444,549,4

9,0Tev 11,010,0Pf 68,4 66,8 64,2 59,5 57,472,066,6 65,0 62,5 58,0 56,070,154,656,560,963,364,868,2Pa 17,5 18,2 19,4 21,5 22,415,817,4 18,1 19,3 21,4 22,315,622,221,319,218,017,215,5Pat 19,0 19,7 20,9 23,0 23,917,318,9 19,6 20,8 22,9 23,817,123,722,820,719,518,717,0Qev 11,8 11,5 11,1 10,2 9,912,411,5 11,2 10,8 10,0 9,612,19,49,710,510,911,211,8Dpev 59,1 56,3 52,1 44,7 41,665,556,0 53,4 49,4 42,4 39,662,137,640,246,850,553,058,8

Ta [°C] - aria esternaTev [°C] - acqua uscente evaporatorePf [kW] - potenza frigoriferaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQev [m³/h] - portata acqua unitàDpev [kPa] - perdita di carico unità" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono ad unità funzionamento non silenziato

Ta [°C] - ambient temperatureTev [°C] - evaporator output water temperaturePf [kW] - cooling capacityPa [kW] - compressor power consumptionPat [kW] - total power input,Qev [m³/h] - evaporator water flowDpev [kPa] - evaporator pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB10ELCAdoc 20/03/2006

Page 19: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B COOLING CAPACITY PERFORMANCEPRESTAZIONI IN REFRIGERAZIONE NECS-N

03024225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 79,1 77,2 74,1 68,6 66,383,677,0 75,1 72,0 66,6 64,381,462,464,670,073,074,979,2Pa 24,0 25,1 26,8 29,9 31,221,623,8 24,8 26,5 29,6 30,921,330,629,326,224,623,521,1Pat 25,5 26,6 28,3 31,4 32,723,125,3 26,3 28,0 31,1 32,422,832,130,827,726,125,022,6Qev 13,6 13,3 12,8 11,8 11,414,413,3 12,9 12,4 11,5 11,114,010,711,112,012,612,913,6Dpev 61,9 58,9 54,3 46,6 43,569,258,6 55,7 51,3 43,9 40,965,538,441,348,452,655,462,0

9,0Tev 11,010,0Pf 85,4 83,4 80,3 74,8 -90,183,3 81,3 78,2 72,7 -88,068,370,776,279,281,285,8Pa 24,8 25,8 27,6 30,7 -22,324,5 25,6 27,3 30,4 -22,031,530,227,125,424,321,8Pat 26,3 27,3 29,1 32,2 -23,826,0 27,1 28,8 31,9 -23,533,031,728,626,925,823,3Qev 14,7 14,4 13,8 12,9 -15,514,4 14,0 13,5 12,5 -15,211,812,213,113,614,014,8Dpev 72,2 68,9 63,8 55,3 -80,568,7 65,5 60,5 52,3 -76,646,249,457,462,165,272,9

03524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 90,6 88,4 84,9 78,7 76,296,088,2 85,9 82,5 76,4 73,993,471,674,180,183,585,790,8Pa 27,8 29,0 30,9 34,3 35,725,127,5 28,7 30,5 33,9 35,324,834,933,530,228,327,124,5Pat 29,3 30,5 32,4 35,8 37,226,629,0 30,2 32,0 35,4 36,826,336,435,031,729,828,626,0Qev 15,6 15,2 14,6 13,6 13,116,515,2 14,8 14,2 13,2 12,716,112,312,813,814,414,715,6Dpev 63,4 60,3 55,6 47,9 44,871,260,0 57,0 52,5 45,1 42,167,439,642,449,553,856,663,7

9,0Tev 11,010,0Pf 98,0 95,7 92,1 85,9 -103,795,6 93,3 89,7 83,5 -101,278,581,187,390,893,198,6Pa 28,7 29,9 31,9 35,3 -26,028,4 29,6 31,5 35,0 -25,736,134,631,229,328,125,4Pat 30,2 31,4 33,4 36,8 -27,529,9 31,1 33,0 36,5 -27,237,636,132,730,829,626,9Qev 16,9 16,5 15,9 14,8 -17,916,5 16,1 15,4 14,4 -17,413,514,015,015,616,017,0Dpev 74,3 70,8 65,6 57,0 -83,270,6 67,2 62,2 53,9 -79,147,650,858,963,767,075,1

04124225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 103,1 100,5 96,7 89,9 87,2109,3100,2 97,7 93,9 87,2 84,5106,381,984,691,194,997,3103,2Pa 31,1 32,4 34,4 38,0 39,528,230,7 32,0 34,0 37,6 39,127,838,637,133,631,630,327,5Pat 33,1 34,4 36,4 40,0 41,530,232,7 34,0 36,0 39,6 41,129,840,639,135,633,632,329,5Qev 17,8 17,3 16,6 15,5 15,018,817,3 16,8 16,2 15,0 14,518,314,114,615,716,316,817,8Dpev 68,5 65,2 60,2 52,2 49,077,064,7 61,5 56,8 49,1 46,072,843,246,153,558,061,068,7

9,0Tev 11,010,0Pf 111,7 109,0 105,0 98,1 -118,2108,8 106,2 102,2 95,4 -115,289,992,699,4103,4106,0112,2Pa 32,2 33,5 35,6 39,3 -29,231,8 33,1 35,2 38,8 -28,940,038,434,832,831,528,5Pat 34,2 35,5 37,6 41,3 -31,233,8 35,1 37,2 40,8 -30,942,040,436,834,833,530,5Qev 19,2 18,8 18,1 16,9 -20,418,7 18,3 17,6 16,4 -19,815,516,017,117,818,319,3Dpev 80,6 76,8 71,2 62,2 -90,276,5 72,8 67,4 58,7 -85,752,155,463,869,072,481,3

04524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 117,1 114,2 109,7 101,9 98,6124,0113,8 111,0 106,6 99,0 95,8120,693,096,1103,6107,9110,6117,2Pa 34,6 36,0 38,2 42,2 43,931,434,3 35,6 37,8 41,8 43,531,043,041,437,435,233,930,7Pat 36,6 38,0 40,2 44,2 45,933,436,3 37,6 39,8 43,8 45,533,045,043,439,437,235,932,7Qev 20,2 19,7 18,9 17,5 17,021,319,6 19,1 18,4 17,0 16,520,816,016,517,818,619,020,2Dpev 65,4 62,2 57,4 49,5 46,473,361,8 58,8 54,2 46,8 43,869,341,344,151,255,558,365,4

9,0Tev 11,010,0Pf 126,7 123,6 118,8 110,5 -134,1123,5 120,4 115,8 107,6 104,3130,7101,5104,8112,7117,3120,3127,3Pa 35,8 37,2 39,4 43,4 -32,535,4 36,8 39,0 43,0 44,732,144,342,638,636,435,031,8Pat 37,8 39,2 41,4 45,4 -34,537,4 38,8 41,0 45,0 46,734,146,344,640,638,437,033,8Qev 21,8 21,3 20,5 19,0 -23,121,3 20,7 19,9 18,5 18,022,517,518,019,420,220,721,9Dpev 76,6 72,9 67,4 58,4 -85,972,8 69,3 64,0 55,3 51,981,649,152,460,765,769,077,4

Ta [°C] - aria esternaTev [°C] - acqua uscente evaporatorePf [kW] - potenza frigoriferaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQev [m³/h] - portata acqua unitàDpev [kPa] - perdita di carico unità" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono ad unità funzionamento non silenziato

Ta [°C] - ambient temperatureTev [°C] - evaporator output water temperaturePf [kW] - cooling capacityPa [kW] - compressor power consumptionPat [kW] - total power input,Qev [m³/h] - evaporator water flowDpev [kPa] - evaporator pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB11ELCAdoc 20/03/2006

Page 20: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B COOLING CAPACITY PERFORMANCEPRESTAZIONI IN REFRIGERAZIONE NECS-N

05124225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 131,7 128,5 123,5 114,7 111,0139,3128,1 125,0 120,1 111,5 108,0135,5104,9108,4116,7121,5124,5131,6Pa 38,0 39,5 41,9 46,1 47,934,537,6 39,1 41,5 45,7 47,534,147,145,341,138,737,233,7Pat 40,5 42,0 44,4 48,6 50,437,040,1 41,6 44,0 48,2 50,036,649,647,843,641,239,736,2Qev 22,7 22,1 21,3 19,7 19,124,022,1 21,5 20,7 19,2 18,623,318,118,720,120,921,422,7Dpev 70,4 67,0 61,9 53,4 50,078,766,6 63,4 58,5 50,5 47,374,544,747,755,359,862,870,3

9,0Tev 11,010,0Pf 142,4 138,9 133,5 123,9 -150,6138,8 135,4 130,2 120,8 116,9146,9113,9117,7126,8132,0135,3143,1Pa 39,1 40,6 43,0 47,1 -35,638,7 40,2 42,6 46,8 48,635,248,346,542,239,938,434,8Pat 41,6 43,1 45,5 49,6 -38,141,2 42,7 45,1 49,3 51,137,750,849,044,742,440,937,3Qev 24,5 23,9 23,0 21,3 -26,023,9 23,3 22,4 20,8 20,125,319,620,321,822,723,324,6Dpev 82,4 78,4 72,4 62,4 -92,278,3 74,5 68,8 59,3 55,587,652,756,365,370,774,383,1

05524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 150,9 147,2 141,5 131,4 127,2159,7146,8 143,2 137,6 127,8 123,7155,3120,2124,2133,7139,1142,6150,9Pa 43,8 45,6 48,3 53,3 55,439,743,4 45,1 47,9 52,8 54,939,354,452,347,444,642,938,8Pat 46,3 48,1 50,8 55,8 57,942,245,9 47,6 50,4 55,3 57,441,856,954,849,947,145,441,3Qev 26,0 25,4 24,4 22,6 21,927,525,3 24,6 23,7 22,0 21,326,720,721,423,023,924,526,0Dpev 83,7 79,6 73,5 63,4 59,493,779,1 75,3 69,5 60,0 56,288,653,156,665,671,174,783,6

9,0Tev 11,010,0Pf 163,3 159,2 153,0 142,1 -172,8159,2 155,3 149,2 138,5 134,1168,4130,6135,0145,3151,2155,0164,1Pa 45,2 46,9 49,7 54,7 -41,044,7 46,5 49,3 54,2 56,340,655,953,848,846,044,340,2Pat 47,7 49,4 52,2 57,2 -43,547,2 49,0 51,8 56,7 58,843,158,456,351,348,546,842,7Qev 28,1 27,4 26,4 24,5 -29,827,4 26,7 25,7 23,9 23,129,022,523,225,026,026,728,3Dpev 98,1 93,3 86,1 74,3 -109,893,1 88,6 81,8 70,6 66,1104,362,767,077,684,188,499,0

06124225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 165,5 161,3 154,7 143,2 138,4175,7161,0 156,9 150,5 139,4 134,7170,9131,0135,5146,4152,6156,6166,1Pa 51,7 53,8 57,0 62,8 65,346,951,1 53,2 56,4 62,2 64,646,364,061,555,852,550,545,7Pat 54,2 56,3 59,5 65,3 67,849,453,6 55,7 58,9 64,7 67,148,866,564,058,355,053,048,2Qev 28,5 27,8 26,6 24,7 23,830,227,7 27,0 25,9 24,0 23,229,422,523,325,226,326,928,6Dpev 88,5 84,0 77,3 66,2 61,999,683,7 79,5 73,1 62,7 58,694,355,459,369,175,179,189,0

9,0Tev 11,010,0Pf 178,8 174,2 167,1 154,6 -189,8174,4 169,9 163,0 150,8 -185,1142,1147,0158,8165,6170,0180,4Pa 53,4 55,5 58,8 64,7 -48,552,9 54,9 58,2 64,1 -48,065,963,457,654,452,347,4Pat 55,9 58,0 61,3 67,2 -51,055,4 57,4 60,7 66,6 -50,568,465,960,156,954,849,9Qev 30,8 30,0 28,8 26,6 -32,730,0 29,3 28,1 26,0 -31,924,525,327,428,529,331,1Dpev 103,4 98,1 90,3 77,3 -116,598,3 93,3 85,8 73,5 -110,765,369,881,588,693,3105,1

Ta [°C] - aria esternaTev [°C] - acqua uscente evaporatorePf [kW] - potenza frigoriferaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQev [m³/h] - portata acqua unitàDpev [kPa] - perdita di carico unità" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono ad unità funzionamento non silenziato

Ta [°C] - ambient temperatureTev [°C] - evaporator output water temperaturePf [kW] - cooling capacityPa [kW] - compressor power consumptionPat [kW] - total power input,Qev [m³/h] - evaporator water flowDpev [kPa] - evaporator pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB12ELCAdoc 20/03/2006

Page 21: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN COOLING CAPACITY PERFORMANCEPRESTAZIONI IN REFRIGERAZIONE NECS-N

01524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 39,6 38,5 36,8 33,8 32,542,038,4 37,4 35,8 32,9 31,640,830,731,934,836,337,339,7Pa 12,3 12,8 13,7 15,4 16,110,912,2 12,7 13,6 15,3 15,910,815,815,113,512,612,010,7Pat 12,9 13,5 14,4 16,0 16,711,612,8 13,4 14,3 15,9 16,611,516,515,814,213,312,711,3Qev 6,8 6,6 6,3 5,8 5,67,26,6 6,4 6,2 5,7 5,47,05,35,56,06,36,46,8Dpev 62,4 59,1 54,1 45,6 42,270,458,9 55,8 51,1 43,1 39,966,537,740,748,252,655,562,7

9,0Tev 11,010,0Pf 42,9 41,7 39,9 36,5 -45,541,8 40,6 38,9 35,6 34,244,333,434,737,839,640,743,2Pa 12,6 13,2 14,1 15,7 -11,312,5 13,1 14,0 15,6 16,311,216,215,513,913,012,411,0Pat 13,2 13,8 14,7 16,3 -11,913,1 13,7 14,6 16,2 16,911,816,816,114,513,613,011,7Qev 7,4 7,2 6,9 6,3 -7,87,2 7,0 6,7 6,1 5,97,65,86,06,56,87,07,4Dpev 73,4 69,5 63,5 53,3 -82,769,6 65,9 60,3 50,7 46,878,544,548,157,162,566,074,4

01824225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 45,5 44,4 42,8 39,9 38,848,244,3 43,2 41,6 38,7 37,646,936,337,540,342,043,145,7Pa 14,0 14,6 15,5 17,1 17,812,613,8 14,4 15,4 17,0 17,612,417,516,815,214,313,712,3Pat 14,6 15,2 16,2 17,8 18,513,214,5 15,1 16,0 17,6 18,313,118,117,415,814,914,312,9Qev 7,8 7,6 7,4 6,9 6,78,37,6 7,4 7,2 6,7 6,58,16,36,56,97,27,47,9Dpev 53,4 50,8 47,1 41,1 38,859,850,5 48,0 44,4 38,6 36,356,734,036,241,945,347,753,6

9,0Tev 11,010,0Pf 49,2 48,1 46,4 43,7 -51,948,0 46,9 45,2 42,4 -50,740,041,244,045,646,749,5Pa 14,5 15,1 16,0 17,6 -13,014,3 14,9 15,8 17,5 -12,918,017,315,714,814,212,7Pat 15,1 15,7 16,6 18,3 -13,715,0 15,6 16,5 18,1 -13,518,618,016,315,414,813,4Qev 8,5 8,3 8,0 7,5 -9,08,3 8,1 7,8 7,3 -8,76,97,17,67,98,18,5Dpev 62,3 59,6 55,5 49,1 -69,659,3 56,6 52,6 46,4 -66,341,343,749,853,756,363,0

02024225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 53,1 51,7 49,4 45,2 43,556,551,7 50,2 48,0 43,9 42,254,941,042,746,648,850,253,4Pa 16,4 17,1 18,3 20,3 21,214,616,2 16,9 18,1 20,2 21,014,520,820,017,916,816,014,3Pat 17,3 18,1 19,2 21,3 22,215,617,2 17,9 19,0 21,1 22,015,421,820,918,917,717,015,3Qev 9,1 8,9 8,5 7,8 7,59,78,9 8,6 8,3 7,6 7,39,57,17,38,08,48,69,2Dpev 51,4 48,6 44,4 37,3 34,458,148,6 46,0 42,0 35,2 32,555,030,633,139,643,445,951,9

9,0Tev 11,010,0Pf 57,5 55,9 53,5 49,0 -61,056,0 54,5 52,1 47,8 -59,544,746,550,753,154,658,0Pa 16,8 17,6 18,7 20,8 -15,116,7 17,4 18,6 20,7 -14,921,420,518,417,316,514,8Pat 17,8 18,5 19,7 21,8 -16,017,6 18,4 19,6 21,6 -15,922,321,519,418,217,515,7Qev 9,9 9,6 9,2 8,4 -10,59,7 9,4 9,0 8,2 -10,37,78,08,79,19,410,0Dpev 60,2 57,0 52,1 43,9 -67,957,2 54,2 49,5 41,6 -64,636,439,446,951,454,361,3

02524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 60,3 58,7 56,1 51,6 49,663,958,6 57,1 54,6 50,2 48,462,247,148,953,155,556,960,4Pa 18,5 19,3 20,5 22,8 23,716,618,3 19,1 20,4 22,6 23,616,523,422,520,219,018,216,3Pat 19,5 20,3 21,5 23,7 24,717,619,3 20,1 21,3 23,6 24,517,424,423,421,219,919,117,3Qev 10,4 10,1 9,7 8,9 8,511,010,1 9,8 9,4 8,7 8,310,78,18,49,19,59,810,4Dpev 45,8 43,4 39,8 33,6 31,151,643,3 41,1 37,6 31,8 29,548,728,030,135,638,840,946,0

9,0Tev 11,010,0Pf 65,2 63,4 60,6 55,4 -69,263,5 61,8 59,1 54,2 52,067,550,852,957,660,361,965,7Pa 18,9 19,7 21,0 23,2 -17,118,8 19,6 20,8 23,1 24,016,923,922,920,719,418,616,8Pat 19,9 20,7 21,9 24,2 -18,019,8 20,5 21,8 24,0 25,017,924,823,921,720,419,617,7Qev 11,2 10,9 10,4 9,5 -11,910,9 10,7 10,2 9,3 9,011,68,89,19,910,410,711,3Dpev 53,7 50,8 46,4 38,8 -60,551,0 48,3 44,1 37,0 34,257,532,635,341,945,848,454,5

Ta [°C] - aria esternaTev [°C] - acqua uscente evaporatorePf [kW] - potenza frigoriferaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQev [m³/h] - portata acqua unitàDpev [kPa] - perdita di carico unità" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono ad unità funzionamento non silenziato

Ta [°C] - ambient temperatureTev [°C] - evaporator output water temperaturePf [kW] - cooling capacityPa [kW] - compressor power consumptionPat [kW] - total power input,Qev [m³/h] - evaporator water flowDpev [kPa] - evaporator pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB13ELCAdoc 20/03/2006

Page 22: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN COOLING CAPACITY PERFORMANCEPRESTAZIONI IN REFRIGERAZIONE NECS-N

03024225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 80,2 78,3 75,3 69,8 67,584,678,0 76,1 73,2 67,8 65,582,463,565,871,174,075,980,1Pa 23,4 24,5 26,2 29,2 30,521,023,2 24,2 25,9 28,9 30,220,829,928,625,624,023,020,6Pat 24,7 25,8 27,4 30,5 31,822,324,5 25,5 27,2 30,2 31,522,131,229,926,925,324,221,9Qev 13,8 13,5 13,0 12,0 11,614,613,4 13,1 12,6 11,7 11,314,210,911,312,212,713,113,8Dpev 63,6 60,6 56,0 48,2 45,170,860,2 57,3 52,9 45,5 42,467,139,942,849,954,156,963,5

9,0Tev 11,010,0Pf 86,6 84,6 81,5 76,0 -91,384,5 82,5 79,4 74,0 -89,169,671,977,380,482,386,9Pa 24,1 25,2 26,9 29,9 -21,723,9 25,0 26,6 29,7 -21,530,829,526,424,723,721,3Pat 25,4 26,5 28,1 31,2 -23,025,2 26,2 27,9 31,0 -22,832,130,727,726,025,022,5Qev 14,9 14,6 14,0 13,1 -15,714,6 14,2 13,7 12,7 -15,312,012,413,313,814,215,0Dpev 74,3 70,9 65,8 57,3 -82,570,6 67,4 62,5 54,1 -78,647,951,159,263,967,174,7

03524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 91,7 89,4 86,0 79,9 77,397,089,2 86,9 83,5 77,5 75,094,472,775,281,184,586,691,8Pa 27,3 28,4 30,3 33,6 35,124,627,0 28,1 29,9 33,3 34,724,334,332,929,627,826,624,0Pat 29,3 30,4 32,3 35,6 37,126,629,0 30,1 31,9 35,3 36,726,336,334,931,629,828,626,0Qev 15,8 15,4 14,8 13,8 13,316,715,3 15,0 14,4 13,3 12,916,312,512,914,014,514,915,8Dpev 64,9 61,8 57,1 49,3 46,272,761,4 58,4 53,9 46,4 43,468,840,843,650,755,157,965,0

9,0Tev 11,010,0Pf 99,2 96,9 93,3 87,1 -104,896,7 94,4 90,8 84,6 -102,279,782,288,491,994,299,6Pa 28,2 29,3 31,2 34,6 -25,427,9 29,0 30,9 34,3 -25,235,434,030,628,727,624,9Pat 30,2 31,3 33,2 36,6 -27,429,9 31,0 32,9 36,3 -27,237,436,032,630,729,626,9Qev 17,1 16,7 16,1 15,0 -18,116,7 16,3 15,6 14,6 -17,613,714,215,215,816,217,2Dpev 76,1 72,6 67,3 58,6 -85,072,3 68,9 63,8 55,4 -80,849,152,360,465,368,576,7

04124225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 103,2 100,6 96,7 89,9 87,1109,4100,3 97,8 93,9 87,2 84,4106,481,884,591,194,997,4103,4Pa 31,1 32,3 34,4 38,0 39,628,130,7 31,9 34,0 37,6 39,127,838,737,133,531,530,327,4Pat 33,1 34,3 36,4 40,0 41,630,132,7 33,9 36,0 39,6 41,129,840,739,135,533,532,329,4Qev 17,8 17,3 16,6 15,5 15,018,817,3 16,8 16,2 15,0 14,518,314,114,515,716,316,817,8Dpev 68,7 65,3 60,3 52,1 48,977,264,9 61,6 56,8 49,0 45,973,043,146,053,558,161,268,9

9,0Tev 11,010,0Pf 111,8 109,1 105,0 98,1 -118,4108,9 106,3 102,2 95,3 -115,489,892,699,5103,5106,1112,4Pa 32,1 33,5 35,5 39,3 -29,131,8 33,1 35,2 38,9 -28,840,038,534,832,731,428,4Pat 34,1 35,5 37,5 41,3 -31,133,8 35,1 37,2 40,9 -30,842,040,536,834,733,430,4Qev 19,3 18,8 18,1 16,9 -20,418,8 18,3 17,6 16,4 -19,915,515,917,117,818,319,4Dpev 80,7 76,9 71,2 62,1 -90,576,6 72,9 67,5 58,6 -86,052,055,363,869,172,681,6

04524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 113,7 110,7 106,1 98,1 94,8120,9110,7 107,7 103,2 95,4 92,1117,689,592,7100,3104,7107,6114,4Pa 36,3 37,7 40,0 44,2 45,932,835,8 37,3 39,6 43,7 45,532,445,043,239,136,835,432,0Pat 38,3 39,7 42,0 46,2 47,934,837,8 39,3 41,6 45,7 47,534,447,045,241,138,837,434,0Qev 19,6 19,1 18,3 16,9 16,320,819,0 18,5 17,8 16,4 15,920,315,415,917,318,018,519,7Dpev 61,7 58,5 53,7 45,9 42,869,758,4 55,4 50,8 43,4 40,566,038,140,948,052,355,262,3

9,0Tev 11,010,0Pf 122,9 119,7 114,8 106,3 -130,5119,8 116,7 111,9 103,5 -127,397,4100,8109,0113,7116,8124,1Pa 37,5 39,0 41,3 45,4 -34,037,1 38,6 40,9 45,0 -33,646,344,640,538,236,733,2Pat 39,5 41,0 43,3 47,4 -36,039,1 40,6 42,9 47,0 -35,648,346,642,540,238,735,2Qev 21,2 20,6 19,8 18,3 -22,520,6 20,1 19,3 17,8 -21,916,817,418,819,620,121,4Dpev 72,1 68,4 63,0 54,0 -81,468,6 65,1 59,8 51,2 -77,445,348,556,761,765,173,5

Ta [°C] - aria esternaTev [°C] - acqua uscente evaporatorePf [kW] - potenza frigoriferaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQev [m³/h] - portata acqua unitàDpev [kPa] - perdita di carico unità" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono ad unità funzionamento non silenziato

Ta [°C] - ambient temperatureTev [°C] - evaporator output water temperaturePf [kW] - cooling capacityPa [kW] - compressor power consumptionPat [kW] - total power input,Qev [m³/h] - evaporator water flowDpev [kPa] - evaporator pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB14ELCAdoc 20/03/2006

Page 23: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN COOLING CAPACITY PERFORMANCEPRESTAZIONI IN REFRIGERAZIONE NECS-N

05124225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 130,6 127,3 122,2 113,2 109,5138,3127,0 123,9 118,9 110,2 106,5134,6103,6107,1115,6120,4123,5130,8Pa 38,5 40,0 42,5 46,8 48,634,938,1 39,6 42,1 46,4 48,234,547,846,041,639,237,734,1Pat 41,0 42,5 45,0 49,3 51,137,440,6 42,1 44,6 48,9 50,737,050,348,544,141,740,236,6Qev 22,5 21,9 21,0 19,5 18,823,821,9 21,3 20,5 19,0 18,323,217,818,419,920,721,322,5Dpev 69,2 65,8 60,6 52,0 48,677,765,5 62,2 57,4 49,3 46,073,543,546,554,258,861,869,4

9,0Tev 11,010,0Pf 141,1 137,6 132,0 122,2 -149,5137,6 134,1 128,8 119,3 -145,8112,4116,2125,5130,7134,1142,1Pa 39,7 41,2 43,6 47,9 -36,039,3 40,8 43,2 47,5 -35,749,047,242,940,438,935,3Pat 42,2 43,7 46,1 50,4 -38,541,8 43,3 45,7 50,0 -38,251,549,745,442,941,437,8Qev 24,3 23,7 22,7 21,1 -25,823,7 23,1 22,2 20,5 -25,119,420,021,622,523,124,5Dpev 80,9 76,9 70,8 60,7 -90,976,9 73,1 67,4 57,8 -86,451,354,964,069,473,082,0

05524225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 145,1 141,3 135,3 124,8 120,4154,3141,3 137,5 131,7 121,5 117,3150,2114,1118,2128,1133,7137,4146,0Pa 46,6 48,5 51,4 56,6 58,842,246,1 47,9 50,8 56,0 58,241,757,655,550,347,445,541,2Pat 49,1 51,0 53,9 59,1 61,344,748,6 50,4 53,3 58,5 60,744,260,158,052,849,948,043,7Qev 25,0 24,3 23,3 21,5 20,726,624,3 23,7 22,7 20,9 20,225,919,620,422,123,023,625,1Dpev 77,4 73,3 67,2 57,2 53,387,573,3 69,4 63,7 54,2 50,582,847,851,360,265,769,378,3

9,0Tev 11,010,0Pf 156,6 152,4 145,9 134,5 -166,6152,8 148,7 142,4 131,3 -162,5123,6128,1138,8145,0149,0158,4Pa 48,1 50,0 52,9 58,1 -43,747,6 49,5 52,4 57,6 -43,259,357,151,949,047,142,7Pat 50,6 52,5 55,4 60,6 -46,250,1 52,0 54,9 60,1 -45,761,859,654,451,549,645,2Qev 27,0 26,3 25,1 23,2 -28,726,3 25,6 24,5 22,6 -28,021,322,123,925,025,727,3Dpev 90,2 85,4 78,3 66,6 -102,085,8 81,3 74,5 63,4 -97,156,160,370,877,381,592,2

06124225 42 4040 353542403525 3232 3030 253230Ta

6,0Tev 8,07,0Pf 158,1 153,7 146,9 134,9 130,0168,7154,0 149,7 143,1 131,5 126,7164,3123,3128,0139,3145,7149,9159,9Pa 55,3 57,5 61,0 67,1 69,650,154,6 56,8 60,2 66,3 68,949,568,165,659,556,153,948,8Pat 57,8 60,0 63,5 69,6 72,152,657,1 59,3 62,7 68,8 71,452,070,668,162,058,656,451,3Qev 27,2 26,5 25,3 23,2 22,429,126,5 25,8 24,6 22,6 21,828,321,222,024,025,125,827,5Dpev 80,7 76,3 69,6 58,8 54,691,976,6 72,3 66,1 55,8 51,887,149,152,962,668,572,582,4

9,0Tev 11,010,0Pf 170,3 165,5 158,1 145,1 -181,8166,3 161,6 154,4 141,8 -177,5133,3138,4150,6157,7162,2173,1Pa 57,3 59,6 63,0 69,2 -52,156,7 58,9 62,3 68,5 -51,470,467,861,758,256,050,8Pat 59,8 62,1 65,5 71,7 -54,659,2 61,4 64,8 71,0 -53,972,970,364,260,758,553,3Qev 29,3 28,5 27,2 25,0 -31,328,6 27,8 26,6 24,4 -30,623,023,825,927,227,929,8Dpev 93,8 88,6 80,8 68,1 -106,989,4 84,4 77,0 65,0 -101,857,461,873,380,385,096,8

Ta [°C] - aria esternaTev [°C] - acqua uscente evaporatorePf [kW] - potenza frigoriferaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQev [m³/h] - portata acqua unitàDpev [kPa] - perdita di carico unità" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono ad unità funzionamento non silenziato

Ta [°C] - ambient temperatureTev [°C] - evaporator output water temperaturePf [kW] - cooling capacityPa [kW] - compressor power consumptionPat [kW] - total power input,Qev [m³/h] - evaporator water flowDpev [kPa] - evaporator pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB15ELCAdoc 20/03/2006

Page 24: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B HEAT PUMP CAPACITY PERF.PRESTAZIONI IN POMPA DI CALORENECS-N

015215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 36,5 41,3 43,3 46,5 52,232,136,7 41,7 43,8 47,1 53,032,353,747,644,242,137,032,5Qcd 6,3 7,2 7,5 8,1 9,15,66,4 7,2 7,6 8,2 9,25,69,38,27,77,36,45,6Dpcd 54,1 69,3 76,3 88,0 110,941,954,7 70,4 77,7 89,9 113,942,3116,391,578,971,455,442,7Pa 11,5 11,7 11,7 11,9 12,111,410,2 10,3 10,4 10,5 10,810,19,69,49,29,29,19,0Pat 12,5 12,7 12,7 12,9 13,112,411,2 11,3 11,4 11,5 11,811,110,610,410,210,210,110,0

45,0Tcd 55,050,0Pt - - - - --- - - - --51,345,942,940,936,231,9Qcd - - - - --- - - - --8,98,07,57,16,35,6Dpcd - - - - --- - - - --107,386,074,968,253,541,5Pa - - - - --- - - - --13,613,313,213,113,012,9Pat - - - - --- - - - --14,614,314,214,114,013,9

018215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 41,0 46,2 48,5 52,1 58,436,241,1 46,5 48,9 52,6 59,236,359,953,049,246,741,236,4Qcd 7,1 8,0 8,4 9,0 10,26,37,1 8,1 8,5 9,1 10,36,310,49,28,58,17,16,3Dpcd 44,0 56,1 61,7 71,1 89,534,444,2 56,6 62,4 72,2 91,634,493,673,163,056,944,334,5Pa 12,8 12,9 13,0 13,1 13,412,711,3 11,5 11,6 11,8 12,111,210,810,510,310,210,09,9Pat 13,8 13,9 14,0 14,1 14,413,712,3 12,5 12,6 12,8 13,112,211,811,511,311,211,010,9

45,0Tcd 55,050,0Pt - - - - --- - - - --57,651,548,145,940,836,2Qcd - - - - --- - - - --10,09,08,48,07,16,3Dpcd - - - - --- - - - --87,469,860,855,443,834,6Pa - - - - --- - - - --14,914,614,614,514,514,5Pat - - - - --- - - - --15,915,615,615,515,515,5

020215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 46,3 52,0 54,5 58,5 65,741,346,3 52,1 54,7 58,8 66,341,466,858,954,752,146,441,7Qcd 8,0 9,0 9,5 10,2 11,47,28,0 9,0 9,5 10,2 11,57,211,610,29,59,08,07,2Dpcd 39,7 50,2 55,1 63,4 80,031,639,7 50,2 55,3 63,9 81,431,782,364,055,250,139,632,0Pa 14,9 15,1 15,2 15,3 15,614,813,2 13,4 13,5 13,6 13,913,112,412,111,911,811,711,6Pat 15,9 16,1 16,2 16,3 16,615,814,2 14,4 14,5 14,6 14,914,113,413,112,912,812,712,6

45,0Tcd 55,050,0Pt - - - - --- - - - --64,858,054,251,846,241,3Qcd - - - - --- - - - --11,310,19,49,08,07,2Dpcd - - - - --- - - - --78,262,654,649,939,831,8Pa - - - - --- - - - --17,517,217,117,016,916,8Pat - - - - --- - - - --18,518,218,118,017,917,8

025215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 55,7 62,9 65,9 70,7 79,349,356,2 63,5 66,6 71,6 80,649,881,672,467,364,156,850,4Qcd 9,7 10,9 11,5 12,3 13,88,69,8 11,0 11,6 12,4 14,08,614,112,511,711,19,88,7Dpcd 39,9 50,8 55,9 64,3 80,831,240,5 51,6 56,9 65,7 83,131,784,966,957,852,541,132,4Pa 17,3 17,5 17,7 17,8 18,217,215,5 15,7 15,8 16,0 16,415,314,714,314,114,013,913,7Pat 18,8 19,0 19,2 19,3 19,718,717,0 17,2 17,3 17,5 17,916,816,215,815,615,515,415,2

45,0Tcd 55,050,0Pt - - - - --- - - - --77,769,765,262,255,348,9Qcd - - - - --- - - - --13,512,111,310,89,68,5Dpcd - - - - --- - - - --77,962,754,850,039,530,9Pa - - - - --- - - - --20,219,919,719,619,419,3Pat - - - - --- - - - --21,721,421,221,120,920,8

Ta [°C] - aria esternaTcd [°C] - acqua uscente condensatorePt [kW] - potenza termicaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQcd [m³/h] - portata acqua condensatoreDpcd [kPa] - perdita di carico condensatore" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Ta [°C] - ambient air temperatureTcd [°C] - condenser output water temperaturePt [kW] - heating capacityPa [kW] - compressor power absorptionPat [kW] - total power consumptionQcd [m³/h] - condenser water flow rateDpcd [kPa] - unit pressure drop with hydronic-group" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB16ELCAdoc 20/03/2006

Page 25: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B HEAT PUMP CAPACITY PERF.PRESTAZIONI IN POMPA DI CALORENECS-N

030215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 69,4 77,8 81,4 87,2 97,862,269,5 77,9 81,6 87,6 98,762,499,687,981,677,869,562,8Qcd 12,1 13,5 14,2 15,2 17,010,812,1 13,5 14,2 15,2 17,110,817,215,214,113,512,010,9Dpcd 48,5 60,9 66,8 76,6 96,339,048,4 60,9 66,9 77,1 97,939,199,277,266,760,648,339,5Pa 21,5 21,9 22,0 22,3 22,921,119,4 19,6 19,8 20,0 20,619,218,518,017,817,717,517,5Pat 23,0 23,4 23,5 23,8 24,422,620,9 21,1 21,3 21,5 22,120,720,019,519,319,219,019,0

45,0Tcd 55,050,0Pt - - - - --- - - - --96,886,681,077,569,462,3Qcd - - - - --- - - - --16,915,114,113,512,110,8Dpcd - - - - --- - - - --94,775,966,460,748,739,2Pa - - - - --- - - - --25,625,024,624,423,823,2Pat - - - - --- - - - --27,126,526,125,925,324,7

035215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 80,2 89,8 94,1 101,0 114,172,380,5 90,1 94,6 101,9 115,772,9117,4102,695,090,581,074,1Qcd 13,9 15,6 16,3 17,6 19,812,614,0 15,6 16,4 17,7 20,112,620,317,816,515,714,012,8Dpcd 50,6 63,4 69,6 80,3 102,341,150,8 63,7 70,1 81,4 105,041,6107,682,370,664,051,242,9Pa 24,6 25,1 25,4 25,8 26,524,322,2 22,6 22,8 23,2 23,921,921,721,020,620,420,119,9Pat 26,1 26,6 26,9 27,3 28,025,823,7 24,1 24,3 24,7 25,423,423,222,522,121,921,621,4

45,0Tcd 55,050,0Pt - - - - --- - - - --112,3100,193,589,380,172,4Qcd - - - - --- - - - --19,617,416,315,613,912,6Dpcd - - - - --- - - - --99,679,169,063,050,641,3Pa - - - - --- - - - --29,528,728,328,027,427,0Pat - - - - --- - - - --31,030,229,829,528,928,5

041215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 89,6 101,1 106,1 114,1 128,579,589,7 101,6 106,8 115,2 130,479,5132,2116,2107,5102,290,380,5Qcd 15,6 17,6 18,4 19,8 22,313,815,6 17,6 18,5 20,0 22,613,822,920,118,617,715,613,9Dpcd 52,7 67,2 74,0 85,5 108,541,552,7 67,6 74,7 86,8 111,341,4114,188,075,468,153,242,2Pa 27,8 28,4 28,7 29,2 30,027,225,0 25,6 25,9 26,3 27,224,524,723,923,423,222,722,3Pat 29,8 30,4 30,7 31,2 32,029,227,0 27,6 27,9 28,3 29,226,526,725,925,425,224,724,3

45,0Tcd 55,050,0Pt - - - - --- - - - --126,7113,0105,4100,789,880,3Qcd - - - - --- - - - --22,119,718,417,515,614,0Dpcd - - - - --- - - - --105,984,273,366,853,142,5Pa - - - - --- - - - --33,332,431,931,631,030,5Pat - - - - --- - - - --35,334,433,933,633,032,5

045215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 103,5 116,1 121,7 130,7 147,492,9103,9 116,8 122,7 132,2 150,093,5152,5133,5123,5117,5104,694,7Qcd 18,0 20,2 21,1 22,7 25,616,118,0 20,3 21,3 22,9 26,016,226,423,121,420,318,116,4Dpcd 52,0 65,5 72,0 83,0 105,541,952,3 66,1 72,8 84,6 108,942,4112,286,073,666,652,843,3Pa 31,3 32,0 32,3 32,8 33,830,828,2 28,8 29,1 29,6 30,627,727,826,926,426,125,625,2Pat 33,3 34,0 34,3 34,8 35,832,830,2 30,8 31,1 31,6 32,629,729,828,928,428,127,627,2

45,0Tcd 55,050,0Pt - - - - --- - - - --144,7129,2120,7115,3103,292,7Qcd - - - - --- - - - --25,222,521,020,118,016,1Dpcd - - - - --- - - - --102,181,471,064,951,941,9Pa - - - - --- - - - --37,336,435,935,634,934,4Pat - - - - --- - - - --39,338,437,937,636,936,4

Ta [°C] - aria esternaTcd [°C] - acqua uscente condensatorePt [kW] - potenza termicaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQcd [m³/h] - portata acqua condensatoreDpcd [kPa] - perdita di carico condensatore" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Ta [°C] - ambient air temperatureTcd [°C] - condenser output water temperaturePt [kW] - heating capacityPa [kW] - compressor power absorptionPat [kW] - total power consumptionQcd [m³/h] - condenser water flow rateDpcd [kPa] - unit pressure drop with hydronic-group" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB17ELCAdoc 20/03/2006

Page 26: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B HEAT PUMP CAPACITY PERF.PRESTAZIONI IN POMPA DI CALORENECS-N

051215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 115,7 130,6 137,0 147,1 165,3102,5116,0 131,5 138,2 148,7 167,6102,2169,7150,1139,1132,2116,2102,0Qcd 20,1 22,7 23,8 25,6 28,717,820,1 22,8 24,0 25,8 29,117,729,426,024,122,920,117,7Dpcd 55,4 70,5 77,6 89,5 112,943,455,4 71,2 78,7 91,1 115,843,1118,392,579,571,855,542,7Pa 34,7 35,5 35,8 36,4 37,434,131,3 32,0 32,3 32,9 33,930,730,729,829,329,028,327,8Pat 37,2 38,0 38,3 38,9 39,936,633,8 34,5 34,8 35,4 36,433,233,232,331,831,530,830,3

45,0Tcd 55,050,0Pt - - - - --- - - - --162,7145,3135,7129,6115,4102,8Qcd - - - - --- - - - --28,325,323,622,620,117,9Dpcd - - - - --- - - - --109,887,676,469,755,343,8Pa - - - - --- - - - --41,440,339,839,538,738,0Pat - - - - --- - - - --43,942,842,342,041,240,5

055215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 134,4 150,9 158,2 169,9 191,5120,5135,0 152,1 159,7 172,0 194,8120,8197,8173,9161,1153,2135,7121,3Qcd 23,4 26,2 27,5 29,5 33,320,923,4 26,4 27,7 29,8 33,821,034,330,127,926,523,521,0Dpcd 67,6 85,1 93,6 108,0 137,354,468,0 86,2 95,1 110,3 141,554,4145,4112,596,587,368,454,7Pa 40,2 41,0 41,3 41,9 43,139,736,1 36,9 37,3 37,9 39,135,635,434,333,733,432,631,9Pat 42,7 43,5 43,8 44,4 45,642,238,6 39,4 39,8 40,4 41,638,137,936,836,235,935,134,4

45,0Tcd 55,050,0Pt - - - - --- - - - --187,9167,6156,5149,6133,8120,4Qcd - - - - --- - - - --32,729,227,326,023,321,0Dpcd - - - - --- - - - --132,6105,592,084,067,354,4Pa - - - - --- - - - --47,646,445,945,544,844,4Pat - - - - --- - - - --50,148,948,448,047,346,9

061215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 148,3 165,8 173,7 186,6 210,8134,2148,5 166,5 174,7 188,3 214,1134,4217,2189,9175,6167,0148,7135,0Qcd 25,8 28,8 30,2 32,4 36,623,325,8 28,9 30,3 32,7 37,123,337,632,930,428,925,823,4Dpcd 72,4 90,4 99,2 114,5 146,159,372,3 90,8 100,1 116,3 150,259,2154,2117,8100,791,172,359,5Pa 45,6 46,4 46,7 47,3 48,645,240,8 41,7 42,0 42,7 44,040,339,938,637,937,536,635,9Pat 48,1 48,9 49,2 49,8 51,147,743,3 44,2 44,5 45,2 46,542,842,441,140,440,039,138,4

45,0Tcd 55,050,0Pt - - - - --- - - - --207,3184,7172,5165,0148,3134,5Qcd - - - - --- - - - --36,132,230,028,725,823,4Dpcd - - - - --- - - - --141,9112,698,389,972,659,7Pa - - - - --- - - - --53,752,551,951,650,950,6Pat - - - - --- - - - --56,255,054,454,153,453,1

Ta [°C] - aria esternaTcd [°C] - acqua uscente condensatorePt [kW] - potenza termicaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQcd [m³/h] - portata acqua condensatoreDpcd [kPa] - perdita di carico condensatore" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Ta [°C] - ambient air temperatureTcd [°C] - condenser output water temperaturePt [kW] - heating capacityPa [kW] - compressor power absorptionPat [kW] - total power consumptionQcd [m³/h] - condenser water flow rateDpcd [kPa] - unit pressure drop with hydronic-group" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB18ELCAdoc 20/03/2006

Page 27: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN HEAT PUMP CAPACITY PERF.PRESTAZIONI IN POMPA DI CALORENECS-N

015215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 35,4 40,2 42,2 45,4 51,231,235,5 40,5 42,6 45,9 51,731,052,246,343,040,835,730,9Qcd 6,2 7,0 7,3 7,9 8,95,46,2 7,0 7,4 8,0 9,05,49,08,07,47,16,25,4Dpcd 50,9 65,5 72,4 83,8 106,539,551,1 66,4 73,5 85,3 108,439,0109,886,674,667,351,438,5Pa 11,5 11,6 11,7 11,8 12,111,410,2 10,3 10,4 10,5 10,810,19,69,39,29,29,09,0Pat 12,1 12,3 12,3 12,5 12,712,110,8 11,0 11,0 11,1 11,410,810,210,09,99,89,79,6

45,0Tcd 55,050,0Pt - - - - --- - - - --50,544,941,839,835,331,3Qcd - - - - --- - - - --8,87,87,36,96,15,4Dpcd - - - - --- - - - --104,182,371,364,750,839,9Pa - - - - --- - - - --13,613,313,213,113,012,9Pat - - - - --- - - - --14,213,913,813,713,613,5

018215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 41,2 46,4 48,7 52,4 59,136,741,4 46,8 49,2 53,0 60,036,860,953,649,647,141,637,0Qcd 7,2 8,1 8,5 9,1 10,36,47,2 8,1 8,5 9,2 10,46,410,59,38,68,27,26,4Dpcd 44,5 56,5 62,2 71,9 91,535,344,8 57,2 63,2 73,4 94,035,596,674,764,157,945,135,7Pa 12,8 13,0 13,0 13,2 13,412,711,3 11,5 11,6 11,8 12,111,210,910,510,310,210,09,9Pat 13,5 13,6 13,7 13,8 14,113,412,0 12,2 12,3 12,4 12,711,811,511,111,010,910,710,6

45,0Tcd 55,050,0Pt - - - - --- - - - --58,151,748,246,041,036,6Qcd - - - - --- - - - --10,19,08,48,07,16,4Dpcd - - - - --- - - - --88,970,461,255,744,235,3Pa - - - - --- - - - --14,914,614,614,514,514,5Pat - - - - --- - - - --15,515,315,215,215,115,2

020215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 45,8 51,7 54,3 58,6 66,440,845,5 51,7 54,5 58,8 66,740,266,858,954,551,745,339,6Qcd 8,0 9,0 9,4 10,2 11,57,17,9 9,0 9,4 10,2 11,67,011,610,29,49,07,86,9Dpcd 38,9 49,6 54,8 63,6 81,830,938,4 49,5 54,9 64,0 82,429,982,363,954,749,237,828,9Pa 14,9 15,1 15,2 15,3 15,714,813,2 13,4 13,5 13,6 13,913,112,412,111,911,811,711,6Pat 15,9 16,1 16,2 16,3 16,615,814,2 14,3 14,4 14,6 14,914,113,313,012,912,812,612,5

45,0Tcd 55,050,0Pt - - - - --- - - - --65,758,154,151,545,941,3Qcd - - - - --- - - - --11,410,19,49,08,07,2Dpcd - - - - --- - - - --80,562,954,449,539,331,8Pa - - - - --- - - - --17,517,217,117,016,916,8Pat - - - - --- - - - --18,518,218,118,017,817,8

025215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 54,1 61,2 64,2 69,0 77,647,754,3 61,7 64,8 69,7 78,547,779,170,465,462,254,747,7Qcd 9,4 10,6 11,2 12,0 13,58,39,4 10,7 11,2 12,1 13,68,313,712,211,310,89,58,3Dpcd 37,6 48,1 53,0 61,2 77,429,337,8 48,7 53,8 62,3 78,929,179,963,254,649,438,129,1Pa 17,3 17,5 17,6 17,8 18,117,115,4 15,6 15,7 15,9 16,315,314,614,314,114,013,813,7Pat 18,2 18,5 18,6 18,7 19,118,116,4 16,6 16,7 16,9 17,216,215,615,215,115,014,814,6

45,0Tcd 55,050,0Pt - - - - --- - - - --76,568,263,660,753,947,8Qcd - - - - --- - - - --13,311,911,110,69,48,3Dpcd - - - - --- - - - --75,460,052,247,537,429,5Pa - - - - --- - - - --20,119,819,719,619,419,2Pat - - - - --- - - - --21,120,820,620,520,320,2

Ta [°C] - aria esternaTcd [°C] - acqua uscente condensatorePt [kW] - potenza termicaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQcd [m³/h] - portata acqua condensatoreDpcd [kPa] - perdita di carico condensatore" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Ta [°C] - ambient air temperatureTcd [°C] - condenser output water temperaturePt [kW] - heating capacityPa [kW] - compressor power absorptionPat [kW] - total power consumptionQcd [m³/h] - condenser water flow rateDpcd [kPa] - unit pressure drop with hydronic-group" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB19ELCAdoc 20/03/2006

Page 28: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN HEAT PUMP CAPACITY PERF.PRESTAZIONI IN POMPA DI CALORENECS-N

030215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 71,5 80,9 84,9 91,2 102,562,971,6 81,5 85,7 92,2 103,762,6104,893,086,382,071,862,4Qcd 12,4 14,1 14,8 15,9 17,810,912,4 14,1 14,9 16,0 18,010,918,216,114,914,212,410,8Dpcd 51,4 65,9 72,6 83,9 105,839,951,5 66,7 73,7 85,3 107,939,3109,986,574,567,351,639,0Pa 21,5 22,0 22,2 22,5 23,121,219,4 19,8 19,9 20,2 20,819,218,818,218,017,817,617,4Pat 22,8 23,3 23,5 23,8 24,422,420,7 21,0 21,2 21,5 22,120,520,119,519,319,118,818,7

45,0Tcd 55,050,0Pt - - - - --- - - - --101,390,284,180,271,363,4Qcd - - - - --- - - - --17,615,714,614,012,411,0Dpcd - - - - --- - - - --103,782,271,465,051,340,6Pa - - - - --- - - - --25,825,224,824,523,923,3Pat - - - - --- - - - --27,126,426,125,825,224,6

035215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 81,4 92,5 97,2 104,7 118,171,581,6 93,3 98,3 106,0 119,770,9121,2107,399,394,282,070,7Qcd 14,1 16,1 16,9 18,2 20,512,414,2 16,2 17,0 18,4 20,812,321,018,617,216,314,212,3Dpcd 52,1 67,3 74,4 86,2 109,740,252,2 68,3 75,7 88,1 112,239,4114,989,977,169,352,639,1Pa 24,7 25,3 25,5 26,0 26,724,222,2 22,8 23,0 23,4 24,121,821,821,220,820,620,119,7Pat 26,7 27,3 27,5 28,0 28,726,224,2 24,8 25,0 25,4 26,123,823,823,222,822,622,121,7

45,0Tcd 55,050,0Pt - - - - --- - - - --116,5103,496,291,781,372,4Qcd - - - - --- - - - --20,318,016,716,014,212,6Dpcd - - - - --- - - - --107,284,473,066,352,241,4Pa - - - - --- - - - --29,728,928,428,127,527,0Pat - - - - --- - - - --31,730,930,430,129,529,0

041215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 92,8 104,9 110,3 118,8 134,482,493,5 106,1 111,7 120,7 137,182,7139,8122,6113,3107,594,583,6Qcd 16,1 18,2 19,2 20,6 23,414,316,2 18,4 19,4 20,9 23,814,324,221,219,618,616,414,5Dpcd 56,6 72,3 79,9 92,7 118,744,657,2 73,7 81,7 95,3 123,044,7127,598,183,775,458,345,6Pa 27,9 28,6 28,9 29,4 30,427,425,2 25,8 26,1 26,6 27,524,625,024,223,723,522,922,4Pat 29,9 30,6 30,9 31,4 32,429,427,2 27,8 28,1 28,6 29,526,627,026,225,725,524,924,4

45,0Tcd 55,050,0Pt - - - - --- - - - --131,9117,0108,9103,992,582,9Qcd - - - - --- - - - --23,020,419,018,116,114,4Dpcd - - - - --- - - - --114,690,278,271,156,445,3Pa - - - - --- - - - --33,632,632,131,831,130,7Pat - - - - --- - - - --35,634,634,133,833,132,7

045215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 103,3 116,1 121,8 131,1 148,392,7103,8 117,0 122,9 132,6 150,893,1153,2134,1124,0117,8104,493,9Qcd 18,0 20,2 21,2 22,8 25,816,118,0 20,3 21,3 23,0 26,216,226,523,221,520,418,116,3Dpcd 51,8 65,5 72,1 83,5 106,841,852,1 66,2 73,2 85,2 110,142,0113,386,874,267,052,642,6Pa 31,3 32,0 32,3 32,8 33,830,828,2 28,8 29,2 29,7 30,727,727,926,926,426,125,625,2Pat 33,3 34,0 34,3 34,8 35,832,830,2 30,8 31,2 31,7 32,729,729,928,928,428,127,627,2

45,0Tcd 55,050,0Pt - - - - --- - - - --145,6129,4120,6115,2103,092,8Qcd - - - - --- - - - --25,422,521,020,117,916,2Dpcd - - - - --- - - - --103,481,771,064,751,742,0Pa - - - - --- - - - --37,436,435,935,634,934,4Pat - - - - --- - - - --39,438,437,937,636,936,4

Ta [°C] - aria esternaTcd [°C] - acqua uscente condensatorePt [kW] - potenza termicaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQcd [m³/h] - portata acqua condensatoreDpcd [kPa] - perdita di carico condensatore" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Ta [°C] - ambient air temperatureTcd [°C] - condenser output water temperaturePt [kW] - heating capacityPa [kW] - compressor power absorptionPat [kW] - total power consumptionQcd [m³/h] - condenser water flow rateDpcd [kPa] - unit pressure drop with hydronic-group" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB20ELCAdoc 20/03/2006

Page 29: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN HEAT PUMP CAPACITY PERF.PRESTAZIONI IN POMPA DI CALORENECS-N

051215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 118,1 132,7 139,2 149,7 169,0105,8118,8 134,0 140,8 151,8 172,2106,2175,1153,9142,5135,4119,6106,6Qcd 20,5 23,1 24,2 26,0 29,418,420,6 23,3 24,4 26,3 29,918,430,326,724,723,420,718,5Dpcd 57,6 72,8 80,1 92,6 118,146,358,2 74,0 81,7 95,0 122,246,5125,997,283,375,358,846,6Pa 34,9 35,6 35,9 36,5 37,634,331,4 32,1 32,5 33,0 34,130,930,929,929,429,128,528,0Pat 37,4 38,1 38,4 39,0 40,136,833,9 34,6 35,0 35,5 36,633,433,432,431,931,631,030,5

45,0Tcd 55,050,0Pt - - - - --- - - - --165,6147,4137,5131,3117,3105,4Qcd - - - - --- - - - --28,825,723,922,920,418,3Dpcd - - - - --- - - - --113,790,178,471,557,146,1Pa - - - - --- - - - --41,540,439,939,538,838,2Pat - - - - --- - - - --44,042,942,442,041,340,7

055215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 132,2 148,1 155,3 166,9 188,7119,2132,6 149,0 156,5 168,7 191,7119,4194,4170,3157,6149,9133,0119,7Qcd 23,0 25,7 27,0 29,0 32,820,723,0 25,9 27,2 29,3 33,320,733,729,527,326,023,020,7Dpcd 65,4 82,0 90,2 104,2 133,253,265,5 82,8 91,3 106,1 137,053,1140,5107,892,383,565,753,2Pa 40,1 40,9 41,2 41,8 43,039,636,0 36,8 37,1 37,7 38,935,535,334,133,533,232,431,9Pat 42,6 43,4 43,7 44,3 45,542,138,5 39,3 39,6 40,2 41,438,037,836,636,035,734,934,4

45,0Tcd 55,050,0Pt - - - - --- - - - --185,4164,9153,9147,1131,9119,3Qcd - - - - --- - - - --32,328,726,825,623,020,8Dpcd - - - - --- - - - --129,1102,288,981,265,353,4Pa - - - - --- - - - --47,446,345,845,444,844,3Pat - - - - --- - - - --49,948,848,347,947,346,8

061215-5 15 1010 7715107-5 55 00 -550Ta

30,0Tcd 40,035,0Pt 145,7 162,5 170,3 183,1 207,4132,6145,6 163,0 171,1 184,5 210,1132,3212,6185,8171,9163,5145,6132,1Qcd 25,3 28,2 29,6 31,8 36,023,025,3 28,3 29,7 32,0 36,422,936,832,229,828,325,222,9Dpcd 69,8 86,8 95,4 110,2 141,457,969,5 87,1 96,0 111,6 144,757,3147,6112,896,587,369,257,0Pa 45,5 46,2 46,6 47,2 48,445,240,7 41,5 41,9 42,5 43,840,239,638,437,737,336,435,8Pat 48,0 48,7 49,1 49,7 50,947,743,2 44,0 44,4 45,0 46,342,742,140,940,239,838,938,3

45,0Tcd 55,050,0Pt - - - - --- - - - --204,4181,5169,4162,0145,9133,3Qcd - - - - --- - - - --35,631,629,528,225,423,2Dpcd - - - - --- - - - --137,9108,794,786,670,358,6Pa - - - - --- - - - --53,552,351,851,450,950,6Pat - - - - --- - - - --56,054,854,353,953,453,1

Ta [°C] - aria esternaTcd [°C] - acqua uscente condensatorePt [kW] - potenza termicaPa [kW] - potenza assorbita compressoriPat [kW] - potenza assorbita totaleQcd [m³/h] - portata acqua condensatoreDpcd [kPa] - perdita di carico condensatore" - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Ta [°C] - ambient air temperatureTcd [°C] - condenser output water temperaturePt [kW] - heating capacityPa [kW] - compressor power absorptionPat [kW] - total power consumptionQcd [m³/h] - condenser water flow rateDpcd [kPa] - unit pressure drop with hydronic-group" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silencedoperation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB21ELCAdoc 20/03/2006

Page 30: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B DESUPERHEATER CAPACITY PERF.PRESTAZIONI DESURRISCALDATORENECS-ND

0152Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 44,0 41,7 41,7 41,7 40,740,7 40,7 39,1 39,1 39,1 36,3 36,3 36,3 35,1 35,1 35,144,044,0Pa 9,6 10,8 10,8 10,8 11,311,3 11,3 12,1 12,1 12,1 13,6 13,6 13,6 14,2 14,2 14,29,69,6Pt.de 8,9 10,8 10,3 9,7 10,311,3 10,9 12,1 11,8 11,2 13,6 13,6 12,9 14,2 14,4 13,78,49,6Qde 1,5 1,9 1,8 1,7 1,82,0 1,9 2,1 2,1 2,0 2,4 2,4 2,3 2,5 2,5 2,41,51,7Dpde 4,2 6,2 5,6 5,1 5,76,8 6,3 7,8 7,5 6,7 9,8 9,9 8,9 10,8 11,0 10,03,84,9

0182Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 49,8 47,2 47,2 47,2 46,146,1 46,1 44,4 44,4 44,4 41,5 41,5 41,5 40,4 40,4 40,449,849,8Pa 11,5 12,8 12,8 12,8 13,313,3 13,3 14,1 14,1 14,1 15,6 15,6 15,6 16,3 16,3 16,311,511,5Pt.de 10,6 12,8 12,1 11,5 12,113,3 12,8 14,1 13,8 13,1 15,6 15,6 14,9 16,3 16,4 15,610,011,5Qde 1,8 2,2 2,1 2,0 2,12,3 2,2 2,5 2,4 2,3 2,7 2,7 2,6 2,8 2,9 2,71,72,0Dpde 6,0 8,6 7,8 7,1 7,89,4 8,7 10,6 10,2 9,2 13,0 13,1 11,8 14,1 14,4 13,15,47,0

0202Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 56,9 53,5 53,5 53,5 52,052,0 52,0 49,7 49,7 49,7 45,4 45,4 45,4 - - 43,656,956,9Pa 14,0 15,7 15,7 15,7 16,416,4 16,4 17,5 17,5 17,5 19,5 19,5 19,5 - - 20,414,014,0Pt.de 13,0 15,7 14,9 14,1 14,916,4 15,7 17,5 17,1 16,2 19,5 19,5 18,5 - - 19,612,314,0Qde 2,3 2,7 2,6 2,5 2,62,8 2,7 3,0 3,0 2,8 3,4 3,4 3,2 - - 3,42,12,4Dpde 9,0 13,1 11,9 10,7 11,914,3 13,2 16,3 15,6 14,1 20,3 20,3 18,4 - - 20,58,110,5

0252Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 66,9 63,5 63,5 63,5 62,062,0 62,0 59,7 59,7 59,7 55,4 55,4 55,4 - - 53,666,966,9Pa 14,7 16,4 16,4 16,4 17,117,1 17,1 18,2 18,2 18,2 20,3 20,3 20,3 - - 21,114,714,7Pt.de 13,6 16,4 15,6 14,8 15,617,1 16,4 18,2 17,8 16,9 20,3 20,3 19,3 - - 20,312,914,7Qde 2,4 2,8 2,7 2,6 2,73,0 2,9 3,2 3,1 2,9 3,5 3,5 3,4 - - 3,52,22,6Dpde 9,9 14,3 12,9 11,7 13,015,6 14,4 17,7 16,9 15,2 21,9 21,9 19,9 - - 22,18,911,5

0302Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 84,5 79,9 79,9 79,9 77,977,9 77,9 74,7 74,7 74,7 69,1 69,1 69,1 - - 66,784,584,5Pa 20,6 22,9 22,9 22,9 24,024,0 24,0 25,6 25,6 25,6 28,6 28,6 28,6 - - 29,820,620,6Pt.de 19,1 22,9 21,8 20,7 21,824,0 23,0 25,6 25,0 23,7 28,6 28,6 27,1 - - 28,618,020,6Qde 3,3 4,0 3,8 3,6 3,84,2 4,0 4,4 4,3 4,1 5,0 5,0 4,7 - - 5,03,13,6Dpde 9,6 13,8 12,5 11,3 12,615,1 13,9 17,2 16,4 14,8 21,4 21,5 19,4 - - 21,78,611,1

0352Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 96,9 91,5 91,5 91,5 89,189,1 89,1 85,6 85,6 85,6 79,3 79,3 79,3 - - 76,696,996,9Pa 23,9 26,5 26,5 26,5 27,627,6 27,6 29,4 29,4 29,4 32,7 32,7 32,7 - - 34,123,923,9Pt.de 22,1 26,5 25,2 23,9 25,227,6 26,5 29,4 28,7 27,2 32,7 32,7 31,1 - - 32,720,923,9Qde 3,8 4,6 4,4 4,2 4,44,8 4,6 5,1 5,0 4,7 5,7 5,7 5,4 - - 5,73,64,1Dpde 12,9 18,4 16,7 15,0 16,720,0 18,5 22,7 21,7 19,6 28,0 28,1 25,5 - - 28,311,615,0

Tde [°C] - temp. acqua uscente desurr.Ta [°C] - temp. aria esternaPf [kW] - potenza frigorifera (acqua uscita evap. = 7 °C)Pa [kW] - potenza assorbita dai compressoriPt.de [kW] - potenza termicaQde [m³/h] - portata acqua desurr.Dpde [kPa] - perdita di carico desurr." - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Tde [°C] - desuperheater output water temperatureTa [°C] - external air temperaturePf [kW] - cooling capacity (evap. output water = 7 °C)Pa [kW] - compressor power consumptionPt.de [kW] - heating capacityQde [m³/h] - desup. water rateDpde [kPa] - desup. pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silenced operation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB22ELCAdoc 20/03/2006

Page 31: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B DESUPERHEATER CAPACITY PERF.PRESTAZIONI DESURRISCALDATORENECS-ND

0412Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 110,2 104,0 104,0 104,0 101,4101,4 101,4 97,4 97,4 97,4 90,5 90,5 90,5 87,7 87,7 87,7110,2110,2Pa 26,9 29,6 29,6 29,6 30,930,9 30,9 32,8 32,8 32,8 36,2 36,2 36,2 37,7 37,7 37,726,926,9Pt.de 24,8 29,6 28,2 26,7 28,130,9 29,6 32,8 32,0 30,3 36,2 36,2 34,4 37,7 38,1 36,223,526,9Qde 4,3 5,1 4,9 4,6 4,95,4 5,1 5,7 5,6 5,3 6,3 6,3 6,0 6,5 6,6 6,34,14,7Dpde 16,2 23,0 20,9 18,8 20,825,0 23,1 28,2 26,9 24,3 34,4 34,5 31,3 37,3 38,2 34,614,618,9

0452Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 125,1 118,1 118,1 118,1 115,2115,2 115,2 110,6 110,6 110,6 102,7 102,7 102,7 99,4 99,4 99,4125,1125,1Pa 30,0 33,1 33,1 33,1 34,434,4 34,4 36,5 36,5 36,5 40,3 40,3 40,3 41,9 41,9 41,930,030,0Pt.de 27,7 33,1 31,4 29,8 31,334,4 33,0 36,5 35,6 33,8 40,3 40,3 38,3 41,9 42,4 40,326,230,0Qde 4,8 5,7 5,5 5,2 5,46,0 5,7 6,3 6,2 5,9 7,0 7,0 6,7 7,3 7,4 7,04,65,2Dpde 14,2 20,2 18,3 16,4 18,221,8 20,2 24,6 23,5 21,2 30,0 30,1 27,3 32,5 33,2 30,112,816,6

0512Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 140,5 132,9 132,9 132,9 129,6129,6 129,6 124,6 124,6 124,6 115,7 115,7 115,7 112,0 112,0 112,0140,5140,5Pa 32,9 36,3 36,3 36,3 37,737,7 37,7 40,0 40,0 40,0 44,1 44,1 44,1 45,9 45,9 45,932,932,9Pt.de 30,4 36,3 34,5 32,6 34,337,7 36,2 40,0 39,0 37,0 44,1 44,1 41,9 45,9 46,3 44,028,832,9Qde 5,3 6,3 6,0 5,7 6,06,5 6,3 6,9 6,8 6,4 7,7 7,7 7,3 8,0 8,0 7,75,05,7Dpde 17,1 24,3 22,0 19,8 21,926,3 24,3 29,5 28,2 25,4 35,9 36,0 32,6 38,8 39,7 36,015,419,9

0552Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 161,1 152,3 152,3 152,3 148,6148,6 148,6 142,8 142,8 142,8 132,6 132,6 132,6 128,4 128,4 128,4161,1161,1Pa 37,9 41,8 41,8 41,8 43,543,5 43,5 46,2 46,2 46,2 51,0 51,0 51,0 53,0 53,0 53,037,937,9Pt.de 35,1 41,8 39,7 37,7 39,643,5 41,8 46,2 45,0 42,7 51,0 51,0 48,4 53,0 53,5 50,933,237,9Qde 6,1 7,3 6,9 6,6 6,97,6 7,3 8,0 7,8 7,4 8,8 8,9 8,4 9,2 9,3 8,95,86,6Dpde 15,3 21,7 19,7 17,7 19,623,5 21,7 26,5 25,2 22,8 32,2 32,3 29,3 34,8 35,6 32,313,717,8

0612Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 177,3 167,1 167,1 167,1 162,8162,8 162,8 156,2 156,2 156,2 144,6 144,6 144,6 139,8 139,8 139,8177,3177,3Pa 44,7 49,3 49,3 49,3 51,351,3 51,3 54,4 54,4 54,4 60,0 60,0 60,0 62,4 62,4 62,444,744,7Pt.de 41,3 49,3 46,8 44,4 46,751,3 49,2 54,4 53,1 50,3 60,0 60,0 57,0 62,4 63,0 59,939,144,7Qde 7,2 8,6 8,1 7,7 8,18,9 8,6 9,4 9,2 8,8 10,4 10,4 9,9 10,8 10,9 10,46,87,7Dpde 21,2 30,2 27,3 24,6 27,232,6 30,2 36,7 35,0 31,6 44,6 44,8 40,6 48,2 49,3 44,719,124,7

Tde [°C] - temp. acqua uscente desurr.Ta [°C] - temp. aria esternaPf [kW] - potenza frigorifera (acqua uscita evap. = 7 °C)Pa [kW] - potenza assorbita dai compressoriPt.de [kW] - potenza termicaQde [m³/h] - portata acqua desurr.Dpde [kPa] - perdita di carico desurr." - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Tde [°C] - desuperheater output water temperatureTa [°C] - external air temperaturePf [kW] - cooling capacity (evap. output water = 7 °C)Pa [kW] - compressor power consumptionPt.de [kW] - heating capacityQde [m³/h] - desup. water rateDpde [kPa] - desup. pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silenced operation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB23ELCAdoc 20/03/2006

Page 32: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN DESUPERHEATER CAPACITY PERF.PRESTAZIONI DESURRISCALDATORENECS-ND

0152Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 42,4 39,9 39,9 39,9 38,838,8 38,8 37,1 37,1 37,1 - - 34,1 - - -42,442,4Pa 10,4 11,7 11,7 11,7 12,312,3 12,3 13,2 13,2 13,2 - - 14,7 - - -10,410,4Pt.de 9,7 11,7 11,1 10,6 11,212,3 11,8 13,2 12,8 12,2 - - 14,0 - - -9,110,4Qde 1,7 2,0 1,9 1,8 1,92,1 2,0 2,3 2,2 2,1 - - 2,4 - - -1,61,8Dpde 5,0 7,3 6,6 6,0 6,78,0 7,4 9,2 8,8 7,9 - - 10,5 - - -4,55,8

0182Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 48,7 45,9 45,9 45,9 44,844,8 44,8 43,1 43,1 43,1 40,2 40,2 40,2 - - 39,048,748,7Pa 12,0 13,4 13,4 13,4 13,913,9 13,9 14,8 14,8 14,8 16,4 16,4 16,4 - - 17,012,012,0Pt.de 11,1 13,4 12,7 12,0 12,713,9 13,4 14,8 14,5 13,7 16,4 16,4 15,6 - - 16,310,512,0Qde 1,9 2,3 2,2 2,1 2,22,4 2,3 2,6 2,5 2,4 2,8 2,8 2,7 - - 2,81,82,1Dpde 6,6 9,5 8,6 7,7 8,610,3 9,5 11,7 11,1 10,1 14,3 14,3 13,0 - - 14,35,97,7

0202Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 57,0 53,6 53,6 53,6 52,152,1 52,1 49,8 49,8 49,8 45,6 45,6 45,6 - - 43,857,057,0Pa 14,0 15,6 15,6 15,6 16,316,3 16,3 17,5 17,5 17,5 19,4 19,4 19,4 - - 20,314,014,0Pt.de 12,9 15,6 14,8 14,1 14,916,3 15,7 17,5 17,0 16,1 19,4 19,4 18,5 - - 19,512,214,0Qde 2,2 2,7 2,6 2,4 2,62,8 2,7 3,0 3,0 2,8 3,4 3,4 3,2 - - 3,42,12,4Dpde 8,9 13,0 11,8 10,6 11,814,2 13,1 16,2 15,5 14,0 20,1 20,2 18,3 - - 20,38,010,4

0252Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 64,5 60,8 60,8 60,8 59,259,2 59,2 56,7 56,7 56,7 - - 52,1 - - -64,564,5Pa 15,9 17,7 17,7 17,7 18,518,5 18,5 19,7 19,7 19,7 - - 21,8 - - -15,915,9Pt.de 14,7 17,7 16,8 15,9 16,818,5 17,7 19,7 19,2 18,2 - - 20,7 - - -13,915,9Qde 2,6 3,1 2,9 2,8 2,93,2 3,1 3,4 3,3 3,2 - - 3,6 - - -2,42,8Dpde 11,5 16,6 15,1 13,6 15,118,1 16,8 20,6 19,6 17,7 - - 23,0 - - -10,413,4

0302Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 85,5 81,0 81,0 81,0 79,079,0 79,0 75,9 75,9 75,9 70,4 70,4 70,4 68,0 68,0 68,085,585,5Pa 20,1 22,4 22,4 22,4 23,423,4 23,4 25,0 25,0 25,0 27,9 27,9 27,9 29,2 29,2 29,220,120,1Pt.de 18,6 22,4 21,3 20,1 21,323,4 22,5 25,0 24,4 23,1 27,9 27,9 26,5 29,2 29,5 28,017,620,1Qde 3,2 3,9 3,7 3,5 3,74,1 3,9 4,3 4,2 4,0 4,8 4,9 4,6 5,1 5,1 4,93,13,5Dpde 9,1 13,1 11,9 10,7 12,014,3 13,3 16,4 15,6 14,1 20,4 20,5 18,6 22,3 22,8 20,78,210,6

0352Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 97,9 92,5 92,5 92,5 90,290,2 90,2 86,7 86,7 86,7 80,4 80,4 80,4 77,8 77,8 77,897,997,9Pa 23,5 26,0 26,0 26,0 27,127,1 27,1 28,9 28,9 28,9 32,1 32,1 32,1 33,5 33,5 33,523,523,5Pt.de 21,7 26,0 24,7 23,4 24,727,1 26,0 28,9 28,2 26,7 32,1 32,1 30,5 33,5 33,8 32,120,523,5Qde 3,8 4,5 4,3 4,1 4,34,7 4,5 5,0 4,9 4,7 5,6 5,6 5,3 5,8 5,9 5,63,64,1Dpde 12,4 17,7 16,1 14,5 16,119,3 17,8 21,9 20,9 18,9 27,0 27,1 24,5 29,4 30,1 27,311,114,4

Tde [°C] - temp. acqua uscente desurr.Ta [°C] - temp. aria esternaPf [kW] - potenza frigorifera (acqua uscita evap. = 7 °C)Pa [kW] - potenza assorbita dai compressoriPt.de [kW] - potenza termicaQde [m³/h] - portata acqua desurr.Dpde [kPa] - perdita di carico desurr." - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Tde [°C] - desuperheater output water temperatureTa [°C] - external air temperaturePf [kW] - cooling capacity (evap. output water = 7 °C)Pa [kW] - compressor power consumptionPt.de [kW] - heating capacityQde [m³/h] - desup. water rateDpde [kPa] - desup. pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silenced operation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB24ELCAdoc 20/03/2006

Page 33: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

LN DESUPERHEATER CAPACITY PERF.PRESTAZIONI DESURRISCALDATORENECS-ND

0412Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 110,4 104,1 104,1 104,1 101,4101,4 101,4 97,4 97,4 97,4 90,4 90,4 90,4 87,6 87,6 87,6110,4110,4Pa 26,8 29,6 29,6 29,6 30,830,8 30,8 32,8 32,8 32,8 36,3 36,3 36,3 37,8 37,8 37,826,826,8Pt.de 24,8 29,6 28,1 26,6 28,130,8 29,6 32,8 31,9 30,3 36,3 36,3 34,5 37,8 38,2 36,323,426,8Qde 4,3 5,1 4,9 4,6 4,95,3 5,1 5,7 5,6 5,3 6,3 6,3 6,0 6,6 6,6 6,34,14,6Dpde 16,1 23,0 20,8 18,7 20,824,9 23,0 28,1 26,8 24,2 34,5 34,6 31,3 37,4 38,3 34,714,518,8

0452Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 122,0 114,8 114,8 114,8 111,8111,8 111,8 107,1 107,1 107,1 98,9 98,9 98,9 - - 95,6122,0122,0Pa 31,3 34,6 34,6 34,6 36,036,0 36,0 38,2 38,2 38,2 42,2 42,2 42,2 - - 43,931,331,3Pt.de 28,9 34,6 32,8 31,1 32,736,0 34,5 38,2 37,3 35,3 42,2 42,2 40,1 - - 42,127,431,3Qde 5,0 6,0 5,7 5,4 5,76,2 6,0 6,6 6,5 6,2 7,3 7,3 7,0 - - 7,34,85,4Dpde 15,5 22,1 20,0 18,0 19,923,9 22,1 26,9 25,7 23,2 32,8 32,9 29,8 - - 32,913,918,1

0512Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 139,6 131,8 131,8 131,8 128,5128,5 128,5 123,4 123,4 123,4 114,3 114,3 114,3 - - 110,5139,6139,6Pa 33,3 36,8 36,8 36,8 38,238,2 38,2 40,6 40,6 40,6 44,8 44,8 44,8 - - 46,633,333,3Pt.de 30,8 36,8 34,9 33,1 34,838,2 36,7 40,6 39,6 37,5 44,8 44,8 42,5 - - 44,729,133,3Qde 5,4 6,4 6,1 5,8 6,16,6 6,4 7,0 6,9 6,5 7,8 7,8 7,4 - - 7,85,15,8Dpde 17,6 24,9 22,6 20,3 22,527,0 25,0 30,4 29,0 26,2 37,0 37,1 33,6 - - 37,115,820,4

0552Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 155,8 146,6 146,6 146,6 142,7142,7 142,7 136,6 136,6 136,6 - - 126,1 - - -155,8155,8Pa 40,3 44,4 44,4 44,4 46,246,2 46,2 49,1 49,1 49,1 - - 54,1 - - -40,340,3Pt.de 37,2 44,4 42,2 40,0 42,146,2 44,4 49,1 47,8 45,4 - - 51,4 - - -35,240,3Qde 6,5 7,7 7,3 7,0 7,38,0 7,7 8,5 8,3 7,9 - - 8,9 - - -6,17,0Dpde 17,2 24,5 22,2 20,0 22,126,5 24,5 29,8 28,5 25,7 - - 32,9 - - -15,520,1

0612Tde 35 40 45 35 35 35 35 35 40 40 40 40 40 45 45 45 45 45Ta 25 30 32 35 40 42Pf 170,5 159,8 159,8 159,8 155,3155,3 155,3 148,4 148,4 148,4 - - 136,4 - - -170,5170,5Pa 47,8 52,7 52,7 52,7 54,854,8 54,8 58,1 58,1 58,1 - - 64,0 - - -47,847,8Pt.de 44,2 52,7 50,1 47,4 49,954,8 52,6 58,1 56,7 53,8 - - 60,8 - - -41,847,8Qde 7,7 9,1 8,7 8,3 8,79,5 9,1 10,1 9,9 9,4 - - 10,6 - - -7,38,3Dpde 24,3 34,5 31,2 28,1 31,137,3 34,5 41,9 40,0 36,1 - - 46,2 - - -21,828,3

Tde [°C] - temp. acqua uscente desurr.Ta [°C] - temp. aria esternaPf [kW] - potenza frigorifera (acqua uscita evap. = 7 °C)Pa [kW] - potenza assorbita dai compressoriPt.de [kW] - potenza termicaQde [m³/h] - portata acqua desurr.Dpde [kPa] - perdita di carico desurr." - " Condizioni fuori dei limiti di funzionamentoNOTA: I dati su fondino si riferiscono al funzionamento non silenziato

Tde [°C] - desuperheater output water temperatureTa [°C] - external air temperaturePf [kW] - cooling capacity (evap. output water = 7 °C)Pa [kW] - compressor power consumptionPt.de [kW] - heating capacityQde [m³/h] - desup. water rateDpde [kPa] - desup. pressure drop" - " Conditions outside the operating rangeNOTE: Data on grey background: unit switched to non-silenced operation.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB25ELCAdoc 20/03/2006

Page 34: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

NECS-NLIMITI DI FUNZIONAMENTO OPERATING RANGE

Acqua scamb. (in)

Salto termicoAcqua scamb. (out)

Thermal differenceExch. water (out)Exch. water (in) (°C)

(°C)(°C)

NECS-N NECS-N

Min Max Min Min MinMax Max MaxDesurrisc. Desuperh. Recov.Recup.

8 (1)

3

23 (1)15 (1)

8

18 (1)(2)26 (1)(2)

4

---------

---------

---

---

NECS-ND -Riscald.Raffred. HeatingCooling/ / / /

18 (3)26 (3)

4

44 (3)48 (3)

85 (1)(6) ---

Limits to exchanger water temperature are valid within the minimum -maximum water flow range indicated in the Hydraulic Data section.

I limiti relativi alla temperatura "acqua scambiatore" sono validi nel rispettodei valori min e max della portata acqua indicata nella pagina Dati idraulici.

HeatingRiscald. Raffred. CoolingVers. Min Max (*) Min Max (*)

/ /

Max (*)

Temp. aria esterna (in) Ambient air temp. (in) (°C) LN -10 (6)(8) 20 (6) -10 (2)(3) 43 (2) ---

Temp. aria esterna (in) Ambient air temp. (in) (°C) B -5 (6) 20 (6) -10 (2)(3) 43-46 (2)(4) ---

(*) Secondo la taglia dell'unità(1) Aria condensatore (in) 35°C(2) Acqua evaporatore (in/out) 12/7°C(3) Aria Esterna 7°C con 87% U.R(4) Portata aria in funzionamento silenziato(5) Portata aria in funzionamento non silenziato(6) Acqua condensatore 40/45 °C(7) Per temperature fino a -8 °C usare miscele incongelabili(8) Solo per versione LN, con Kit LT da ordinare come accessorio, esclusele taglie 0152, 0182, 0202, 0252

(*) According to unit size(1) Condenser air temp. (in) 35 °C(2) Evaporator water temp. (in/out) 12/7 °C(3) Ambient Air temp. 7°C with 87% R.H.(4) Condenser air-flow in low-noise operating mode(5) Condenser air-flow in standard operating mode(6) Condenser water temp. 40/45 °C(7) With temperatures down to -8°C use anti-freeze mixtures.(8) Only for LN version, with Kit LT to order like accessory, excluded size0152, 0182, 0202, 0252

SOLUZIONI DI GLICOLE ETILENICO ETHYLENE GLYCOL MIXTURE

Ethylene glycol and water mixtures, used as a heat-conveyingfluid, cause a variation in unit performance. For correct data, usethe factors indicated in the following table.

Soluzioni di acqua e glicole etilenico usate come fluidotermovettore, provocano una variazione delle prestazioni delleunità. Per i dati corretti utilizzare i fattori riportati nella tabella.

1,3

0 -5 -10 -15 -20 -25 -30 -35

0 12% 20% 30% 35% 40% 45% 50%

Temperatura di congelamento (°C)

Percentuale di glicole etilenico in peso

cPfcQcdp

Ethylene glycol percentage by weight

Freezing point (°C)

111

0,9851,021,07

0,981,041,11

0,9741,0751,18

0,971,111,22

0,9651,141,24

0,9641,171,27

0,961,2

cPf cooling capacity correction factorcQ flow correction factorcdp pressure drop correction factor

For data concerning other kind of anti-freeze solutions (e.g. propyleneglycol) please contact our Sales Department.

cPf: fattore corretivo potenza frigoriferacQ: fattore corretivo portatacdp: fattore corretivo perdite di carico

Per funzionamento delle unità con miscele incongelabili diverse (es. glicolepropilenico) contattare il nostro ufficio Commerciale.

FOULING FACTORSFATTORI DI INCROSTAZIONELe prestazioni fornite dalle tabelle si riferiscono alla condizione ditubi puliti con fattore di incrostazione =1. Per valori diversi delfattore di incrostazione, moltiplicare i dati delle tabelle diprestazione per i coefficienti riportati nella seguente tabella.

Performances are based on clean condition of tubes (fouling factor=1). For different fouling values, performance should be adjustedusing the correction factors shown in the following table.

Desurriscaldatore

f1 fk1 fx1 f2 fk2 fx2 f3 fk3 fx3

Fattori di incrostazione Evaporatore RecuperatoreFouling factors Evaporator Heat recovery Desuperheater

1 1 10,96 0,99 0,990,93 0,98 0,98

0,99 0,990,98 0,980,95 0,95

1,03 1,031,03 1,031,04 1,04 1,04 1,041,06 1,06 1,06 1,06

-5

-4

-4

4,4 x 100,86 x 101,72 x 10

(m² °C/W)(m² °C/W)(m² °C/W)

f1 - f2 - f3: fattori correzione potenzialitàfk1 - fk2 - fk3: fattori correzione potenza assorbita compressorifx1 - fx2 - fx3: fattori correzione potenza assorbita totale

f1 - f2 - f3 capacity correction factorsfk1 - fk2 - fk3 compressor power input correction factorsfx1 - fx2 - fx3 total power input correction factors

HFC R410AB100HL_105_110D_CV_03_07_IT_GB26ELCAdoc 20/03/2006

Page 35: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B - LNNECS-N

DATI IDRAULICI HYDRAULIC DATA

PORTATA ACQUA E PERDITA DI CARICO WATER FLOW AND PRESSURE DROPWater flow in the heat exchangers is given by:Q=Px 0,86/Dt

Q: water flow (m³/h)Dt: difference between inlet and outlet water temp. (°C)P: heat exchanger capacity (kW)

Pressure drop is given by:Dp=K x Q² /1000

Q: water flow (m³/h)Dp: pressure drop (kPa)K: unit size ratio

La portata d'acqua negli scambiatori si calcola con la seguenterelazione:Q=Px 0,86/ Dt

Q: portata d'acqua (m³/h)Dt: salto termico sull'acqua (°C)P: potenza dello scambiatore (kW)

Le perdite di carico si calcolano con la seguente relazione:Dp=K x Q²/1000

Q: portata d'acqua (m³/h)Dp: perdite di carico (kPa)K: coefficiente riportato per le varie grandezze

Evaporatore / Evaporator Rec. (1) - Cond (2) Desurrisc. / DesuperheaterGRANDEZZA

SIZE Q min Q max Q min Q max Q min Q maxK K Km³/h m³/hm³/h m³/hmin m³m³/h m³/h

C.a. / W.c.

4,1 10,8 1.346 0,40152 1767 2,5---- - 4,6 12,3 869 0,50182 1767 2,8---- - 5,1 13,7 615 0,50202 1767 3,5---- - 6,2 16,5 426 0,60252 1767 3,6---- - 7,7 20,7 334 0,80302 871 5,1---- - 8,9 23,7 261 0,90352 871 5,8---- - 10,1 27,0 218 1,10412 871 6,6---- - 11,5 30,7 161 1,20452 613 7,3---- - 12,9 34,5 137 1,40512 613 8,0---- - 14,8 39,5 124 1,50552 412 9,2---- - 16,2 43,2 109 1,70612 412 10,8---- -

K evap : Compreso filtro meccanico a rete, di serie.Q min : minima portata acqua ammessa allo scambiatoreQ max : massima portata acqua ammessa allo scambiatoreC.a. min : minimo contenuto d'acqua ammesso nell'impianto, con logica dicontrollo tipo tradizionale

(1) Rec. = Recuperatore. Valido per tutte le unità con recupero totale dicalore(2) Cond. = Condensatore. Valido per le sole unità con condensazione adacqua. Nelle unità con recupero di calore, i valori sono validi sia per ilcondensatore che per il recuperatore.

K evap : standard mains filter includedQ min: minimum water flow admitted to the heat exchanger.Q max: maximum water flow admitted to the heat exchanger.W.c min.: minimum water content admitted in the plant, using traditionalcontrol logic

(1) Rec. = Heat Recovery. For units with total heat recovery.(2) Cond. = Condenser. For water to water type units. In units with heat-recovery , this data is valid for both the condensing and the heat-recovery exchangers.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB27ELCAdoc 20/03/2006

Page 36: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

NECS-NELECTRICAL DATADATI ELETTRICI

Valori massimi

Grandezza

Compressori Ventilatori (1)

nF.L.I.[kW]

F.L.A.[A]

L.R.A.[A]

S.A.[A]

F.L.I.[kW]

F.L.I.[kW]

F.L.A.[A]

F.L.A.[A]

Maximum values

Size

Compressor Fan motors (1)Totale (1) (2)

Total unit (1) (2)

2 4,41952x9 2x15,3 19 35 1150152 2 4,411112x10,1 2x16,4 21,2 37 1320182 2 4,411182x11,8 2x20,4 24,6 45 1430202 2 6,61,51182x13,2 2x22,6 27,9 52 1470252 2 6,61,51982x16,9 2x27,9 35,3 62 2330302 2 8,82198 / 2251x16,9+1x22,3 1x27,9+1x36,1 41,2 73 2620352 2 8,822252x22,3 2x36,1 46,6 81 2700412 2 8,82225 / 2721x22,3+1x27,4 1x36,1+1x45,8 51,7 91 3170452 2 112,52722x27,4 2x45,8 57,3 103 3290512 2 112,5272 / 3101x27,4+1x35,8 1x45,8+1x58,9 65,7 116 3670552 2 112,53102x35,8 2x58,9 74,1 129 3800612

F.L.I. Potenza assorbita massimaF.L.A. Corrente assorbita massimaL.R.A. Corrente di spunto del singolo compressoreS.A. Corrente di spunto

(1) Valori calcolati considerando la versione con il massimo numerodi ventilatori funzionanti alla massima potenza assorbita(2) Valori cautelativi da considerare nel dimensionamento dei cavi dialimentazione e protezione linea

Alimentazione elettrica: 400/3/50Variazione di tensione ammessa: 10%Massimo sbilanciamento di fase: 3%

F.L.I. Full load power input at max admissible conditionF.L.A. Full load current at max admissible conditionL.R.A. Locked rotor amperes for single compressorS.A. Starting current

(1) Values calculated referring to the version with the maximumnumber of fans working at the max absorbed current(2) Safety values to be considered when cabling the unit for powersupply and line-protections

Power supply 400/3/50Voltage tolerance: 10%Maximum voltage unbalance: 3%

HFC R410AB100HL_105_110D_CV_03_07_IT_GB28ELCAdoc 20/03/2006

Page 37: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

NECS-NBLIVELLI SONORI A PIENO CARICO FULL LOAD SOUND LEVEL

Bande d'ottava [Hz] a 10 m - Octave band [Hz] at 10 mLivelli sonori totali - Total sound level

800040002000100050025012563GrandezzaSize

PressureLivelli di pressione sonora [dB] Sound pressure level [dB]

PressionePotenzaPower

--1 m (coil)10 m (medium)

54 52 56 53 49 47 40 39 840152 68 55 54 52 56 53 49 47 40 39 840182 68 55 54 52 56 53 49 47 40 39 840202 68 55 54 52 56 53 49 47 40 39 840252 68 55 55 53 57 54 50 48 41 40 850302 68 56 56 54 58 55 51 49 42 41 860352 69 57 56 54 58 55 51 49 42 41 860412 69 57 56 54 58 55 51 49 42 41 860452 69 57 57 55 59 56 52 50 43 42 870512 69 58 57 55 59 56 52 50 43 42 870552 69 58 57 55 59 56 52 50 43 42 870612 69 58

Condizioni di funzionamento: Working conditionsAcqua evaporatore (in/out) 12/7 [°C]Aria condensatore 35 [°C]

Evaporator water (in/out) 12/7 [°C]Ambient air 35 [°C]

Potenza sonora Sound powerClimaveneta determina il valore della Potenza Sonora sulla base dimisure effettuate in accordo alla normativa ISO 3744, nel rispetto diquanto richiesto dalla certificazione EUROVENT (prove acusticheEurovent 8/1).

Climaveneta gives the Sound Power level values based onmeasurements carried out according to ISO 3744, as required byEUROVENT certification ( Eurovent 8/1 sound tests ).

Detta certificazione si riferisce specificatamente alla PotenzaSonora in dB(A) che è quindi l'unico dato acustico da considerarsiimpegnativo.

Such certification refers specifically to the sound Power Level indB(A). This is therefore the only acoustic data to be considered asbinding.

Pressione sonora a 10 metri Sound pressure at 10 metresPressione sonora in campo libero su piano riflettente (fatt. di direttivitàQ=2), a 10 metri di distanza dalla superficie esterna dell'unità. Valoremedio calcolato dalla potenza sonora.Si possono considerare i seguenti coefficienti correttivi:pressione sonora a 5 metri + 5 dBpressione sonora a 15 metri - 3 dBpressione sonora a 20 metri - 6 dB

Free field sound pressure on a reflecting surface (directivity fact. Q=2),at a distance of 10 meters from the external surface of the unit. Averagevalue calculated from the sound power.The following factor correct to you can be considered:sound pressure at 5 m + 5dBsound pressure at 15 m - 3 dBsound pressure at 20 m - 6 dB

Pressione sonora ad 1 metro Sound pressure at 1 meterPressione sonora in campo libero su piano riflettente (fatt. di direttivitàQ=2), ad 1 metro di distanza dalla superficie esterna dell'unità. Valoremedio calcolato dalla potenza sonora.

Free field sound pressure on a reflecting surface (directivity fact. Q=2), ata distance of 1meter from the external surface of the unit. Average valuecalculated from the sound power.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB29ELCAdoc 20/03/2006

Page 38: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

NECS-NLNLIVELLI SONORI A PIENO CARICO FULL LOAD SOUND LEVEL

Bande d'ottava [Hz] a 10 m - Octave band [Hz] at 10 mLivelli sonori totali - Total sound level

800040002000100050025012563GrandezzaSize

PressureLivelli di pressione sonora [dB] Sound pressure level [dB]

PressionePotenzaPower

--1 m (coil)10 m (medium)

51 49 52 49 44 40 32 30 790152 63 50 51 49 52 49 44 40 32 30 790182 63 50 52 50 53 50 45 41 33 31 800202 63 51 52 50 53 50 45 41 33 31 800252 63 51 53 51 54 51 46 42 34 32 810302 64 52 53 51 55 52 48 46 39 38 830352 66 54 53 51 55 52 48 46 39 38 830412 66 54 53 51 55 52 48 46 39 38 830452 66 54 54 52 56 53 49 47 40 39 840512 66 55 54 52 56 53 49 47 40 39 840552 66 55 54 52 56 53 49 47 40 39 840612 66 55

Condizioni di funzionamento: Working conditionsAcqua evaporatore (in/out) 12/7 [°C]Aria condensatore 35 [°C]

Evaporator water (in/out) 12/7 [°C]Ambient air 35 [°C]

Potenza sonora Sound powerClimaveneta determina il valore della Potenza Sonora sulla base dimisure effettuate in accordo alla normativa ISO 3744, nel rispetto diquanto richiesto dalla certificazione EUROVENT (prove acusticheEurovent 8/1).

Climaveneta gives the Sound Power level values based onmeasurements carried out according to ISO 3744, as required byEUROVENT certification ( Eurovent 8/1 sound tests ).

Detta certificazione si riferisce specificatamente alla PotenzaSonora in dB(A) che è quindi l'unico dato acustico da considerarsiimpegnativo.

Such certification refers specifically to the sound Power Level indB(A). This is therefore the only acoustic data to be considered asbinding.

Pressione sonora a 10 metri Sound pressure at 10 metresPressione sonora in campo libero su piano riflettente (fatt. di direttivitàQ=2), a 10 metri di distanza dalla superficie esterna dell'unità. Valoremedio calcolato dalla potenza sonora.Si possono considerare i seguenti coefficienti correttivi:pressione sonora a 5 metri + 5 dBpressione sonora a 15 metri - 3 dBpressione sonora a 20 metri - 6 dB

Free field sound pressure on a reflecting surface (directivity fact. Q=2),at a distance of 10 meters from the external surface of the unit. Averagevalue calculated from the sound power.The following factor correct to you can be considered:sound pressure at 5 m + 5dBsound pressure at 15 m - 3 dBsound pressure at 20 m - 6 dB

Pressione sonora ad 1 metro Sound pressure at 1 meterPressione sonora in campo libero su piano riflettente (fatt. di direttivitàQ=2), ad 1 metro di distanza dalla superficie esterna dell'unità. Valoremedio calcolato dalla potenza sonora.

Free field sound pressure on a reflecting surface (directivity fact. Q=2), ata distance of 1meter from the external surface of the unit. Average valuecalculated from the sound power.

HFC R410AB100HL_105_110D_CV_03_07_IT_GB30ELCAdoc 20/03/2006

Page 39: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

DISEGNI DIMENSIONALI E DI SOLLEVAMENTO DIMENSIONAL AND LIFTING DRAWINGS

ELCAdoc 20/03/2006 HFC R410AA1

NOTA:Per l’installazione, fare riferimento alla documentazione inviata successivamente alla definizione delcontratto d’acquisto. I dati tecnici riportati sono da ritenersi indicativi. CLIMAVENETA si riserva il dirittodi poter cambiare tali caratteristiche in ogni momento.

REMARKS:For installation purposes, please refer to the documentation sent after the purchase-contract. This technicaldata should be considered as indicative. CLIMAVENETA may modify them at any moment.

NECS-NB - LN

B100HL_105_110D_CV_03_07_IT_

Attacchi idrici Water connections

Rif 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552 0612

1 - 2Evaporatore Evaporator

UNI ISO RP 2" 2" 2" 2" 2" 2" 2" 2 1/2" 2 1/2" 2 1/2" 2 1/2"

4 - 5Desurriscaldatore Desuperheator

UNI ISO RP 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2"

Page 40: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

NECS-NB - LNDISEGNI DIMENSIONALI DIMENSIONAL DRAWINGS

Grandezza / Size

DIMENSIONI E PESI / DIMENSIONS AND WEIGHTS

A B HNECS-N NECS-ND

P. / W.[mm] [mm] [mm] [kg]

A B P. / W. A B P. / W.[mm] [mm] [mm]

H H[mm] [mm] [mm][kg] [kg]

SPAZI DI RISPETTO (vedi pag. succ.)FREE SPACES (See fol. page)

[mm] [mm] [mm] [mm]R1 R2 R3 R4

0152 B 1695 1120 400 1695 1120 410 1000 1000 600 600 1420 14200152 LN 1695 1120 400 1695 1120 410 1000 1000 600 600 1420 14200182 B 1695 1120 410 1695 1120 420 1000 1000 600 600 1420 14200182 LN 1695 1120 420 1695 1120 430 1000 1000 600 600 1420 14200202 B 1695 1120 420 1695 1120 430 1000 1000 600 600 1420 14200202 LN 2195 1120 460 2195 1120 470 1000 1000 600 600 1420 14200252 B 2195 1120 500 2195 1120 510 1000 1000 600 600 1420 14200252 LN 2195 1120 500 2195 1120 510 1000 1000 600 600 1420 14200302 B 2195 1120 630 2195 1120 640 1000 1000 600 600 1420 14200302 LN 2745 1120 710 2745 1120 720 1000 1000 600 600 1420 14200352 B 2195 1120 690 2195 1120 700 1000 1000 600 600 1420 14200352 LN 2745 1120 770 2745 1120 780 1000 1000 600 600 1620 16200412 B 2745 1120 770 2745 1120 790 1000 1000 600 600 1420 14200412 LN 2745 1120 830 2745 1120 850 1000 1000 600 600 1620 16200452 B 2745 1120 850 2745 1120 860 1000 1000 600 600 1420 14200452 LN 2745 1120 880 2745 1120 890 1000 1000 600 600 1620 16200512 B 3245 1120 950 3245 1120 970 1000 1000 600 600 1620 16200512 LN 3245 1120 990 3245 1120 1010 1000 1000 600 600 1620 16200552 B 3245 1120 1020 3245 1120 1030 1000 1000 600 600 1620 16200552 LN 3245 1120 1020 3245 1120 1030 1000 1000 600 600 1620 16200612 B 3245 1120 1030 3245 1120 1040 1000 1000 600 600 1620 16200612 LN 3245 1120 1030 3245 1120 1040 1000 1000 600 600 1620 1620

ELCAdoc 20/03/2006 B100HL_105_110D_CV_03_07_IT_GB HFC R410A2A

Page 41: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

NECS-NB - LNDISEGNI DIMENSIONALI DIMENSIONAL DRAWINGS

Attenzione: Corrente elettrica!

Attenzione: Superficie tagliente!

Attenzione: Ventilatori!

Warning: Electrical power!

Warning: Sharp edges!

Warning: Fans!

SPAZI DI RISPETTO - SOLLEVAMENTO - SIMBOLOGIA FREE SPACES - LIFTING MODE - SYMBOLS

ISTRUZIONI DI SOLLEVAMENTO INSTRUCTIONS- Assicurarsi che tutti i pannelli siano saldamente fissati prima di movimentare l'unità.- Prima del sollevamento, verificare il peso dell'unità sull'etichetta CE.- Utilizzare tutti, e soli, i punti di sollevamento indicati,- Utilizzare funi di uguale lunghezza.- Utilizzare bilancino distanziatore (non incluso)- Movimentare l'unità con cautela e senza movimenti bruschi.

- Make sure that all the panels are firmly fixed in place before moving the unit.- Before lifting it, check the weight on the CE label.- Use all, and only, the lifting points provided,- Use slings of equal length,- Use a spread-bar (not included)- Move the unit carefully and avoid abrupt movements.

ELCAdoc 20/03/2006 B100HL_105_110D_CV_03_07_IT_GB HFC R410A3A

Page 42: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B 1

NECS-NGRUPPO IDRONICO (optional) HYDRONIC GROUPS (optional)

B100HL_105_110D_CV_03_07_IT_GB

Configurazioni disponibiliGruppo idronico 1 pompaGruppo idronico 2 pompeGruppo idronico 1 pompa con accumuloGruppo idronico 2 pompe con accumulo

Unità compatte PLUG and PLAY.

Le unità del sistema NECS possono essere fornite congruppo idronico, che racchiude in sè i principale componen-ti permettendo di ottimizzare spazi, tempi e costi di installa-zione idraulica ed elettrica dell’unità stessa.L’innovativo controllo QuickMind, di cui sono dotate le unitàdel sistema NECS, è stato concepito per operare inimpianti a basso contenuto d’acqua, permettendo di fornirealternative altamente professionali all’installazione di unitàdotate di gruppo di accumulo.Per particolari applicazioni può essere comunque richiesto,come accessorio, un serbatoio da installarsi all’internodell’unità.

Available configurationsHydronic group 1 pompHydronic group 2 pompsHydronic group 1 pomp with water tankHydronic group 2 pomps with water tank

Compact units PLUG and PLY

The units in the NECS system are fitted standard with ahydronic group. This houses all the main hydrauliccomponents, thereby optimising hydraulic and electricinstallation space, time and cost.The innovative QuickMind control fitted to the units in theNECS system, has been designed to work on systems witha low water content, offering highly professional alternativesto the installation of systems featuring storage units.For special applications, a tank to install inside the unit isavailable on request.

Sono esclusi dalla nostra fornitura i seguenti accessori, maè consigliato il loro utilizzo per un corretto funzionamentodell’impianto:- Manometri a monte e a valle dell’unità.- Giunti elastici sulle tubazioni.- Rubinetti intercettatori- Termometro di controllo in uscita

The supply does not include the following accessories thoughthese are recommended to ensure correct system operation:- Pressure gauges upline and downline from the unit.- Flexible joints on piping.- On-off valves- Outlet control thermometer

Pompa bassa prevalenza a 2 poli.Elettropompa orizzontale centrifuga monoblocco,monogirante, ad aspirazione assiale e mandata radiale,con corpo pompa e girante in acciaio inossidabile AISI304L . La porzione di albero a contatto con il liquido è inacciaio inossidabile. Tenuta meccanica con componenti inmateriale ceramico/carbone/NBR/AISI304. Motore elettricotrifase con grado di protezione IP55 e classe d’isolamentoF, adatta per servizio continuo.

Seconda pompaE’ possibile richiedere una seconda pompa in stand-by allaprima, per alta o bassa pressione. Le pompe sono a rotazioneprogrammata e, in caso di guasto della pompa in esercizio,a scambio automatico. Il gruppo idronico con due pompesarà completo di valvole di non ritorno, atte a garantire ilcorretto funzionamento dell’unità.

Pompe specialiPer pompe con configurazioni diverse, contattare l’areacommerciale.

AccumuloIn tutte le unità è prevista la possibilità di inserire un accumu-lo, all’interno dell’unità, con capacità da 85 o 250 litri, a se-conda delle taglie. E’ realizzato con lamiera di acciaio, salda-ta con le migliori tecnologie e protetta contro le corrosioni dauna successiva verniciatura. Ogni serbatoio è collaudato a7,5 bar per garantire 5 bar di esercizio. La coibentazione, confunzione anticondensa, è realizzata con materassino inpolietilene reticolato espanso dello spessore di 20 mm ac-coppiato con film esterno antigraffio metallizzato goffrato.Come accessorio può essere richiesta una resistenza antigelo.

Filtro meccanico lato acqua (di serie)Filtro a “Y” progettato e costruito per poter intercettare leimpurità presenti nel circuito idraulico. E’ dotato di cartucciaa rete con maglia inox e fori passaggio 0,9 mm, sostituibilesenza rimuovere il corpo valvola dalla tubazione.

2-pole low head pumpHorizontal one-piece centrifuge pump with one impeller,axial suction and radial delivery, AISI 304L stainless steelpump body impeller. The section of shaft in contact with theliquid is made from stainless steel. Mechanical seal madefrom components in ceramics/carbon/NBR/AISI304. Three-phase electric motor protected to IP55, insulation class F,suitable for continuous service.

Second pumpA second stand-by pump for high or low pressures is availableon request. The pumps are automatically exchanged on thebasis of a rotation programme and the stand-by pump cutsin automatically if the primary pump fails. The two-pumphydronic assembly is also fitted with check valves to ensurethe unit works correctly.

Special pumpsFor pumps with different configurations, please contact oursales department.

Water TankAll units can be fitted with an internal storage tank holding85 or 250 litres, depending on the version.This is made from sheet steel, welded using leading-edgetechnologies and protected from corrosion with a coat of paint.Each tank is tested to 7.5 bar to ensure an operating pressureof 5 bar.The condensation-proof lagging is made from a 20 mm layerof foamed cross-linked polyethylene bonded to an externalembossed metallic scratchproof film.

Water-side mechanical filter (standard)Y-filter designed and built to capture the impurities in thehydraulic circuit. It is fitted with a 0.9 mm stainless steelmesh cartridge which can be replaced without removingthe valve body from the piping.

Page 43: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B 2

NECS-NGRUPPO IDRONICO (optional) HYDRONIC GROUPS (optional)

B100HL_105_110D_CV_03_07_IT_GB

Il gruppo idronico è composto da:- P Elettropompa orizzontale centrifuga monoblocco.- MA Manometro circuito idrico- F Flussostato- RT Valvola di taratura della portata- SC Valvola di scarico- S1 Sonda temperatura ingresso acqua scambiatore- S2 Sonda temperatura uscita acqua scambiatore- SF Sfiato aria- VA Valvola di sicurezza tarata a 3 bar.- VE Vaso di espansione da 8 lt, precaricato a 1,5 bar- VR Valvola di ritegno (solo se presente P2).- FI Filtro a rete. Fornito di serie.

The hydronic group comprises:- P Horizontal one-piece centrifuge pump.- MA Hydraulic circuit pressure gauge- F Flow switch- RT Flow control valve- SC Discharge valve- S1 Exchanger input water temperature probe- S2 Exchanger outlet water temperature probe- SF Air vent- VA 3 bar safety valve.- VE 8-litre expansion tanks, pre-pressurised to 1,5 bar- VR Check valve (only if P2 is fitted)- FI Mains filter. Standard.

Configurazione Gruppo idronico 2 pompe Configuration Hydronic group 2 pomps

Il gruppo idronico è composto da:- P Elettropompa orizzontale centrifuga monoblocco.- MA Manometro circuito idrico- F Flussostato- RT Valvola di taratura della portata- SC Valvola di scarico- S1 Sonda temperatura ingresso acqua scambiatore- S2 Sonda temperatura uscita acqua scambiatore- SF Sfiato aria- VA Valvola di sicurezza tarata a 3 bar.- VE Vaso di espansione da 8 lt, precaricato a 1,5 bar- FI Filtro a rete. Fornito di serie.

The hydronic group comprises:- P Horizontal one-piece centrifuge pump.- MA Hydraulic circuit pressure gauge- F Flow switch- RT Flow control valve- SC Discharge valve- S1 Exchanger input water temperature probe- S2 Exchanger outlet water temperature probe- SF Air vent- VA 3 bar safety valve.- VE 8-litre expansion tanks, pre-pressurised to 1,5 bar- FI Mains filter. Standard.

Configurazione Gruppo idronico 1 pompa Configuration Hydronic group 1 pomp

Il quadro elettrico dell’unità è implementato con interruttorimagnetotermici

The electrical panel of the unit is protected with Automaticcircuit breakers

Page 44: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B 3

NECS-NGRUPPO IDRONICO (optional) HYDRONIC GROUPS (optional)

B100HL_105_110D_CV_03_07_IT_GB

Il gruppo idronico è composto da:- P Elettropompa orizzontale centrifuga monoblocco- AC Accumulo- MA Manometro circuito idrico- F Flussostato- RT Valvola di taratura della portata- SC Valvola di scarico- S1 Sonda temperatura ingresso acqua scambiatore- S2 Sonda temperatura uscita acqua scambiatore- SF Sfiato aria- VA Valvola di sicurezza tarata a 3 bar.- VE Vaso di espansione da 8 lt, precaricato a 1,5 bar

con capacità accumulo da 85 e 150 lt.Vaso di espansione da 12 lt, precaricato a 1,5 bar,con capacità accumulo da 190 e 250 lt.

- FI Filtro a rete. Fornito di serie.

The hydronic group comprises:- P Horizontal one-piece centrifuge pump- AC Storage tank- MA Hydraulic circuit pressure gauge- F Flow switch- RT Flow control valve- SC Discharge valve- S1 Exchanger input water temperature probe- S2 Exchanger outlet water temperature probe- SF Air vent- VA 3 bar safety valve.- VE 8-litre expansion tanks, pre-pressurised to 1,5 bar,

with storage tank 85 and 150 lt.12-litre expansion tanks, pre-pressurised to 1,5 bar,with storage tank 190 and 250 lt.

- FI Mains filter. Standard.

Configurazione Gruppo idronico 1 pompa con accumulo Configuration Hydronic group 1 pomp with water tank

Il gruppo idronico è composto da:- P Elettropompa orizzontale centrifuga monoblocco- AC Accumulo- MA Manometro circuito idrico- F Flussostato- RT Valvola di taratura della portata- SC Valvola di scarico- S1 Sonda temperatura ingresso acqua scambiatore- S2 Sonda temperatura uscita acqua scambiatore- SF Sfiato aria- VA Valvola di sicurezza tarata a 3 bar.- VE Vaso di espansione da 8 lt, precaricato a 1,5 bar

con capacità accumulo da 85 e 150 lt.Vaso di espansione da 12 lt, precaricato a 1,5 bar,con capacità accumulo da 190 e 250 lt.

- VR Valvola di ritegno (solo se presente P2).- FI Filtro a rete. Fornito di serie.

The hydronic group comprises:- P Horizontal one-piece centrifuge pump- AC Storage tank- MA Hydraulic circuit pressure gauge- F Flow switch- RT Flow control valve- SC Discharge valve- S1 Exchanger input water temperature probe- S2 Exchanger outlet water temperature probe- SF Air vent- VA 3 bar safety valve.- VE 8-litre expansion tanks, pre-pressurised to 1,5 bar,

with storage tank 85 and 150 lt.12-litre expansion tanks, pre-pressurised to 1,5 bar,with storage tank 190 and 250 lt.

- VR Check valve (only if P2 is fitted)- FI Mains filter. Standard.

Configurazione Gruppo idronico 2 pompe con accumulo Configuration Hydronic group 2 pomps with water tank

Il quadro elettrico dell’unità è implementato con interruttorimagnetotermici

The electrical panel of the unit is protected with Automaticcircuit breakers

Page 45: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B 4

NECS-NGRUPPO IDRONICO (optional) HYDRONIC GROUPS (optional)

B100HL_105_110D_CV_03_07_IT_GB

(1) Valori riferite alle condizioni nominaliPf Potenza frigorifera dell’unitàQ Portata acqua all’evaporatoreF.L.I. Potenza assorbita dalla pompaF.L.A. Corrente assorbita dalla pompaHp Prevalenza pompaDpu Perdita di carico totale del gruppo idronicoHu Prevalenza utileACC Capacità accumuloKG1 Supplemento di peso per sole pompeKG2 Supplemento di peso per pompe e accumulo vuoto

Coefficienti per il calcolo delle perdite di carico, comprensivo delfiltro a rete di serie:K P1 Unità con Gruppo idronico con una pompaK P2 Unità con Gruppo idronico con due pompeK AC1 Unità con 1 Pompa e AccumuloK AC2 Unità con 2 Pompe e Accumulo

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pumpHp Head of pumpDpu Total pressure drop of hydronic groupHu Working headACC Water Tank capacityKG1 Extra weight witht only pumpsKG2 Extra weight witht pumps and water tank

Coefficients for calculating pressure drops comprise standardmains filter:K P1 Unit with Hydronic group and one pumpK P2 Unit with Hydronic group and two pumpsK AC1 Unit with 1 Pump and Storage tankK AC2 Unit with 2 Pumps and Storage tank

Caratteristiche pompe Pump characteristics

A B C D EBP 2 poli BP 2 poli BP 2 poli BP 2 poli BP 2 poli

[m ^3/h] [kPa] [m ^3/h] [kPa] [m ^3/h] [kPa] [m ^3/h] [kPa] [m ^3/h] [kPa]

6 139 6 188 6 221 12 224 12 2448 132 8 182 8 213 16 216 16 23910 124 10 174 10 204 20 205 20 23012 115 12 164,5 12 195,2 24 193 24 22014 104,3 14 154 14 187 28 179 28 20716 93 16 142 16 176,5 32 165 32 19318 79 18 129 18 165 36 150 36 17720 66 20 115 20 152 40 134 40 15921 59 22 100 22 138

152 - 182 202 - 252 302 - 352 412 512 - 612Q 6,5 Q 10 Q 14,1 Q 16,2 Q 18,4H 137 H 174 H 162 H 215 H 234

dw c 500/3dw c 300/1,1(R) dw c 300/1,5dw c 300/1,1 dw c 500/2,2

50

70

90

110

130

150

170

190

210

230

250

4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

Q [m 3/h]

H [k

Pa]

A

B

C D

E

Unità senza Accumulo Unit without tank Unità con Accumulo Unit with tankGrand. 1Pompa - 1 Pump 2 Pompe - 2 Pumps 1Pompa - 1 Pump 2 Pompe - 2 PumpsSize Dpu Hu Dpu Hu Dpu Hu Dpu Hu

[kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa]0152 1391 58 79 1422 60 77 1422 60 77 1422 60 770182 915 50 84 948 51 83 948 51 83 948 51 83 0202 645 44 137 676 46 135 676 46 135 676 46 1350252 458 45 129 490 48 126 490 48 126 490 48 1260302 365 56 138 396 61 133 396 61 133 396 61 1330352 291 59 126 321 65 120 321 65 120 321 65 120 0412 251 65 151 281 73 143 281 73 143 281 73 143 0452 174 59 173 185 63 169 185 63 169 185 63 169 0512 151 64 162 162 69 157 162 69 157 162 69 1570552 130 73 145 141 79 139 141 79 139 141 79 1390612 122 82 129 133 90 121 133 90 121 133 90 121

K AC1 K AC2K P1 K P2

Grand. Pf (1) Q (1) Rif. Pompa F.L.I. F.L.A. Hp Acc (lt) - Tank (lt)Size [kW] [m3/h] Pump ref. [kW] [A] [kPa] B LN HT-SL0152 38,0 6,5 A 1,1 2,5 137 85 85 850182 43,0 7,4 A 1,1 2,5 134 85 85 850202 48,0 8,3 B 1,1 2,5 180 85 150 1500252 58,0 10,0 B 1,1 2,5 174 85 150 1500302 72,0 12,4 C 1,5 3,2 166 150 190 1900352 82,0 14,1 C 1,5 3,2 162 150 190 1900412 94,0 16,2 D 2,2 4,8 215 190 190 1900452 107,0 18,4 E 3,0 5,6 234 190 190 1900512 120,0 20,6 E 3,0 5,6 228 250 250 2500552 138,0 23,7 E 3,0 5,6 221 250 250 2500612 151,0 26,0 E 3,0 5,6 214 250 250 250

Page 46: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

B 5

NECS-NGRUPPO IDRONICO (optional) HYDRONIC GROUPS (optional)

B100HL_105_110D_CV_03_07_IT_GB

VARIAZIONI DI PESO

Variazioni di peso, in Kg, rispetto l’Unità Standard.

Il peso dell’Unità Standard è disponibile alla pag. A2.

Nessuna variazione di peso è prevista tra la versione BassaPrevalenza ed Alta Prevalenza.

WEIGHT DIFFERENCESWeight differences, in Kg, compared with the StandardUnit.

The weight of the Standard Unit is indicated on page A2.

There is no difference in weight between the low headand high head versions.

Senza ACCUMULO Without WATER TANK

1 Pompa - 1 Pump 2 Pompe - 2 PumpsB LN HT SL B LN HT SL

152 35 35 30 30 70 70 60 60

182 35 35 35 35 70 70 70 70

202 35 30 35 35 70 60 70 70

252 35 30 35 35 70 60 70 70

302 35 30 35 35 70 60 70 70

352 35 35 35 35 70 70 70 70

412 35 35 40 40 70 70 80 80

452 35 35 45 45 70 70 90 90

512 50 50 45 45 100 100 90 90

552 50 50 45 45 100 100 90 90

612 50 50 45 45 100 100 90 90

Con ACCUMULO PIENO (In funzionamento) With WATER TANK FULL (working)

1 Pompa - 1 Pump 2 Pompe - 2 Pumps

B LN HT SL B LN HT SL152 145 145 150 150 180 180 180 180

182 145 145 135 135 180 180 170 170

202 145 220 225 225 180 250 260 260

252 145 220 215 215 180 250 250 250

302 225 270 275 275 260 300 310 310

352 225 275 265 265 260 310 300 300

412 275 275 270 270 310 310 310 310

452 275 275 245 245 310 310 290 290

512 350 350 345 345 400 400 390 390

552 350 350 345 345 400 400 390 390

612 350 350 345 345 400 400 390 390

Con ACCUMULO VUOTO (Trasporto) With WATER TANK EMPTY (Transport)1 Pompa - 1 Pump 2 Pompe - 2 Pumps

B LN HT SL B LN HT SL152 60 60 65 65 95 95 95 95

182 60 60 50 50 95 95 85 85

202 60 70 75 75 95 100 110 110

252 60 70 65 65 95 100 100 100

302 75 80 85 85 110 110 120 120

352 75 85 75 75 110 120 110 110

412 85 85 80 80 120 120 120 120

452 85 85 55 55 120 120 100 100

512 100 100 95 95 150 150 140 140

552 100 100 95 95 150 150 140 140

612 100 100 95 95 150 150 140 140

Page 47: NECS-N / NECS-ND - Cuypers Koeltechniek · Produced presentation Auto Tuning Defrost Accessories Electronic control features ... in the Eurovent Certification Programme. The products

I dati contenuti nel presente bollettino possono essere variati senza obbligo di preavvisoAll specification and data are subject to change without notice

36061 BASSANO DEL GRAPPA (VICENZA) ITALIA - VIA SARSON 57/cTEL. +39 / 0424 509 500 (r.a.) - TELEFAX +39 / 0424 509 509http://www.climaveneta.it