Navisphere Manager Simulator Lab Exercise Navisphere Manager Simulator Lab Guide i

Navisphere Manager Simulator Lab Guide

Embed Size (px)

Citation preview

Page 1: Navisphere Manager Simulator Lab Guide

Navisphere Manager Simulator Lab Exercise

Navisphere Manager Simulator Lab Guide

i

Page 2: Navisphere Manager Simulator Lab Guide
Page 3: Navisphere Manager Simulator Lab Guide

Navisphere Manager Simulator Lab Exercises

Description This lab is designed to familiarize the user with configuration and management of a CLARiiON Storage System using the Navisphere Manager Graphical User Interface (GUI). The Navisphere Manager GUI is very robust in its ability to provide the necessary information for day-to-day management of a CLARiiON data storage environment, while providing an easy to use, Windows look and feel. This lab will walk the user through the steps necessary to create and allocate data storage on a CLARiiON Storage System as well as acquaint the user with optional CLARiiON software that allows for disaster recovery and staging data for online data backups. This lab provides step-by-step directions for configuring CLARiiON hardware and software using Navisphere Manager 6.x.

Objectives Upon completion of this exercise, you will be able to:

• Configure RAID Groups on a CLARiiON Storage System • Bind LUNs to RAID Groups on a CLARiiON Storage System • Configure Storage Groups on a CLARiiON Storage System • Configure Mirrors on CLARiiON Storage Systems • Add Clones to a Clone Group on a CLARiiON Storage System • Create SnapShots on a CLARiiON Storage System

Navisphere Manager Simulator Lab Guide

Lab pg 1

Page 4: Navisphere Manager Simulator Lab Guide

Materials Required The following tools/aids/materials are required to perform the steps in this lab:

• 1 - laptop or desktop computer running either Windows NT or Windows 2000 operating system

• 1 – Copy of the Navisphere Manager Simulator software (CD or download) installed on the computer

• 1 – Copy of this Lab Document • Internet Explorer v5.5 installed on service laptop or management workstation • Java Runtime Environment (will be installed if not on the computer) • Optional - Navisphere 6.x Manager User Guide (explains some of the parameters

not used in these exercises)

Simulator Lab Guide Navisphere Manager

Lab pg 2

Page 5: Navisphere Manager Simulator Lab Guide

Lab 1: Logging into the Navisphere Manager Navisphere Manager requires a valid username and password to log in on the Manager Graphical User Interface (GUI). This is to authenticate the user and determine his authorization level for management and configuration of the CLARiiON Storage Environment. Navisphere Manager Simulator 1. If you haven’t already done so, Start the Navisphere Manager interface by choosing Start –

programs – Navisphere Simulation – Launch Navisphere Simulator

2. At the login screen enter Username: manager and Password: manager

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 3

Page 6: Navisphere Manager Simulator Lab Guide

Navisphere Manager Simulator 3. The Enterprise Storage Window will be displayed with any CLARiiON Storage Systems in the

Domain being visible.

Simulator Lab Guide Navisphere Manager

Lab pg 4

Page 7: Navisphere Manager Simulator Lab Guide

Lab 2: Navigating the Navisphere Manager User Interface Use these steps to learn how to navigate the Navisphere Manager User Interface (UI) software. You will be asked to navigate the Enterprise Storage window by expanding the objects that represent logical and physical components on the CLARiiON Storage Systems. Navigating the Manager User Interface 1. From the enterprise storage Window, Expand the FC4700-1 [FC4700 Series] object by clicking

on the + sign, or by double clicking the object name FC4700-1.

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 5

Page 8: Navisphere Manager Simulator Lab Guide

Navigating the Manager User Interface 2. Expand the RAID Groups object to see any RAID Groups created on the Storage System.

Simulator Lab Guide Navisphere Manager

Lab pg 6

Page 9: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 7

Navigating the Manager User Interface 3. Storage Processor Objects are visible by expanding the SP A or SP B objects.

Page 10: Navisphere Manager Simulator Lab Guide

Navigating the Manager User Interface 4. SnapView Objects are viewed by expanding the SnapView object, then expanding any

underlying objects available.

Simulator Lab Guide Navisphere Manager

Lab pg 8

Page 11: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 9

Navigating the Manager User Interface 5. Information on Storage Group population can be found under the Storage Group

6. Practice expanding and shrinking objects for the Storage System FC4700-2.

Page 12: Navisphere Manager Simulator Lab Guide

Navigating the Manager User Interface 7. New users can be added by clicking on Tools – Security – User Management.

8. Click Add to create a new user for your domain. Create a user named Admin, with the

password of password. Click OK and confirm the new user creation

9. This completes the Navigating the Manager User Interface Exercise.

Simulator Lab Guide Navisphere Manager

Lab pg 10

Page 13: Navisphere Manager Simulator Lab Guide

Lab 3: Creating RAID Groups You will begin to create a shared configuration on the storage systems by creating RAID Groups. RAID Groups are a grouping of disks to allow for the creation of LUNs to share storage to the Hosts. Creating RAID Groups 1. Using the LUN and Storage Group Worksheets for FC4700-1 and FC4700-2 from the

Navisphere Simulator Planning Guide, complete this exercise.

2. Expand FC4700-1 – RAID Groups. Right-Click on FC4700-1 and select Create RAID Group.

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 11

Page 14: Navisphere Manager Simulator Lab Guide

Creating RAID Groups 3. To create the first RAID Group 1, in the FC4700-1 – Create RAID Group window, select :

RAID Group ID:1 Number of Disks: 5 Expansion/Defragmentation Priority: Medium Disk Selection: Automatic Click Apply and confirm creation of the RAID Group

Simulator Lab Guide Navisphere Manager

Lab pg 12

Page 15: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 13

Creating RAID Groups 4. To create RAID Group 2, in the FC4700-1 – Create RAID Group window, select :

RAID Group ID:2 Number of Disks: 5 Expansion/Defragmentation Priority: Medium Disk Selection: Automatic Click Apply and confirm creation of the RAID Group

Page 16: Navisphere Manager Simulator Lab Guide

Creating RAID Groups 5. To create RAID Group 3, in the FC4700-1 – Create RAID Group window, select :

RAID Group ID:3 Number of Disks: 2 Expansion/Defragmentation Priority: Medium Disk Selection: Automatic Click Apply and confirm creation of the RAID Group

Simulator Lab Guide Navisphere Manager

Lab pg 14

Page 17: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 15

Creating RAID Groups 6. Review the RAID Groups you created on FC4700-1 by expanding the RAID Groups object in

Navisphere Manager as shown.

Repeat Step 3, 4 and 5 (which you have just completed) to create RAID Groups on the array FC4700-2.

Page 18: Navisphere Manager Simulator Lab Guide

Creating RAID Groups 7. Expand both FC4700-1 and FC4700-2 RAID Groups to view the completed RAID Groups on

both Storage Systems.

8.

This completes the Creating RAID Groups Exercise.

Simulator Lab Guide Navisphere Manager

Lab pg 16

Page 19: Navisphere Manager Simulator Lab Guide

Lab 4: Binding LUNs for Host Access to Storage System Resources Binding LUNs on a CLARiiON is how you share storage with a Host. LUNs are represented as disks to the host when using the Operating System’s Disk Management or Volume Management Software. Binding LUNs for Host Access 1. To bind a LUN on a CLARiiON Storage System, right-click the storage system object and select

Bind LUN.

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 17

Page 20: Navisphere Manager Simulator Lab Guide

Binding LUNs for Host Access 2. For FC4700-1, Bind LUN 0x10 as shown in the graphic and listed below, then click Apply and

confirm LUN bind: RAID Type: RAID 5 RAID Group: 2 LUN ID: 10 Element Size: 128 (default) Rebuild Priority: ASAP (default) Verify Priority: ASAP (default) Enable Read Cache: Checked (default) Enable Write Cache: Checked (default) Enable Auto Assign: Clear (default) Number of LUNs to Bind: 1 (default) Default Owner: SP A Alignment Offset: 0 (default) LUN Size: 30 GB

Simulator Lab Guide Navisphere Manager

Lab pg 18

Page 21: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 19

Binding LUNs for Host Access 3. Bind LUN 20 as shown in graphic and listed below and click Apply then confirm LUN bind:

RAID Type: RAID 1, RAID Group: 3, LUN ID:20 Enable Read Cache: Checked (default) Enable Write Cache: Checked (default) Enable Auto Assign: Clear (default) Number of LUNs to Bind: 1 (default) Default Owner: SP B, Alignment Offset: 0 (default), LUN Size: 10 GB

Bind two additional LUNs, LUN ID 25 and LUN ID 30, using the following data: LUN 25: LUN 30: RAID Type: RAID 5 RAID Type: RAID 5 RAID Group: 1 RAID Group: 1 LUN ID:25 LUN ID: 30 Enable Read Cache: Checked (default) Enable Read Cache: Checked (default) Enable Write Cache: Checked (default) Enable Write Cache: Checked (default) Enable Auto Assign: Clear (default) Enable Auto Assign: Clear (default) Number of LUNs to Bind: 1 (default) Number of LUNs to Bind: 1 (default) Default Owner: SP A Default Owner: SP B Alignment Offset: 0 (default) Alignment Offset: 0 (default) LUN Size: 30 GB LUN Size: 30 GB

Page 22: Navisphere Manager Simulator Lab Guide

Binding LUNs for Host Access 4. Expand FC4700-1 – RAID Groups – RAID Group 1, RAID Group 2, and RAID Group 3 to

confirm that the LUNs have been created in the correct RAID Groups.

Simulator Lab Guide Navisphere Manager

Lab pg 20

Page 23: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 21

Binding LUNs for Host Access 5. Bind LUNS for FC4700-2.

Right-click FC4700-2 and select Bind LUN.

Page 24: Navisphere Manager Simulator Lab Guide

Binding LUNs for Host Access 6. Bind FC4700-2 LUN10 as shown in the graphic below.

Simulator Lab Guide Navisphere Manager

Lab pg 22

Page 25: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 23

Binding LUNs for Host Access 7. Bind FC4700-2 LUN 20 as shown in the graphic below.

Page 26: Navisphere Manager Simulator Lab Guide

Binding LUNs for Host Access 8. Bind FC4700-2 LUN 11 as shown in the graphic below. Note that Read and Write Cache are

not enabled.

Bind two additional LUNs, LUN ID 12 and LUN ID 30, using the following data: To Bind LUN 12: To Bind LUN 30: RAID Type: RAID 5 RAID Type: RAID 5 RAID Group: 1 RAID Group: 1 LUN ID:12 LUN ID: 30 Enable Read Cache: Checked (default) Enable Read Cache: Checked (default) Enable Write Cache: Checked (default) Enable Write Cache: Checked (default) Enable Auto Assign: Clear (default) Enable Auto Assign: Clear (default) Number of LUNs to Bind: 1 (default) Number of LUNs to Bind: 1 (default) Default Owner: SP A Default Owner: SP A Alignment Offset: 0 (default) Alignment Offset: 0 (default) LUN Size: 20 GB LUN Size: 20 GB

Simulator Lab Guide Navisphere Manager

Lab pg 24

Page 27: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 25

Binding LUNs for Host Access 9. When all LUNs have been bound, review the configuration by expanding the RAID Groups for

FC4700-2.

Page 28: Navisphere Manager Simulator Lab Guide

Binding LUNs for Host Access 10. Review Storage Processor ownership of FC4700-2 LUNs by expanding the SP A and SP B

objects in Navisphere Manager. FC4700-1 LUNs should also be reviewed for correct Storage Processor ownership.

11. This completes the Bind LUN Lab Exercise.

Simulator Lab Guide Navisphere Manager

Lab pg 26

Page 29: Navisphere Manager Simulator Lab Guide

Lab 5: Populating Storage Groups Storage Groups contain a Host and the CLARiiON resources available to that Host. This is how Access Logix software keeps track of which Host has which resources. Populating Storage Groups 1. Storage Groups are used to connect host computers to LUN disk storage when using Access

Logix base code on the CLARiiON Storage System.

2. To place Hosts in the FC4700-1 Storage Groups, Expand FC4700-1 then expand Storage Groups. There should be two Storage Groups available, SG1 and SG2.

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 27

Page 30: Navisphere Manager Simulator Lab Guide

Populating Storage Groups 3. To add a host Storage Group SG1, right-click on SG1 and select Properties.

Simulator Lab Guide Navisphere Manager

Lab pg 28

Page 31: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 29

Populating Storage Groups 4. In the SG1 Storage Group Properties window, select the Hosts tab then select Seawin-40 from

the Available Hosts.

Page 32: Navisphere Manager Simulator Lab Guide

Populating Storage Groups 5. Click the highlighted arrow to move Seawin-40 from Available Hosts to Hosts to be

Connected. Click Apply and confirm the connection of Seawin-40 to SG1. Once you have confirmed the Host connection to SG1, click cancel to exit the Storage Group Properties window.

Simulator Lab Guide Navisphere Manager

Lab pg 30

Page 33: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 31

Populating Storage Groups 6. To connect Seawin-41 to SG2, follow the same procedure as with SG1. Right-click SG2 and

select Properties. Click on the Hosts Tab. Select Seawin-41 from the Available Hosts. Click the highlighted arrow to move Seawin-41 from Available Hosts to Hosts to be Connected. Click Apply and confirm the connection of Seawin-41 to SG2.

Page 34: Navisphere Manager Simulator Lab Guide

Populating Storage Groups 7. In the Enterprise Storage Window, expand FC4700-1 – Storage Groups – SG1 – Hosts, as well

as SG2 – Hosts. This will confirm that each Host is in the correct Storage Group.

Simulator Lab Guide Navisphere Manager

Lab pg 32

Page 35: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 33

Populating Storage Groups 8. Following the same procedures, place the Hosts into the Storage Groups on FC4700-2. When

completed, the Storage Tree in Manager for FC4700-2 should look like the graphic below. Note that the hosts are in different Storage Groups.

Page 36: Navisphere Manager Simulator Lab Guide

Populating Storage Groups 9. Place LUNs in their appropriate Storage Groups. For FC4700-1 expand FC4700-1 and right-

click SG1. Click Select LUNs from the drop-down menu.

Simulator Lab Guide Navisphere Manager

Lab pg 34

Page 37: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 35

Populating Storage Groups 10. Select LUNs 10 and 20 from the Available LUNs and move them to Selected LUNs with the

right arrow. Click Apply and then confirm the operation. When completed, the window should look like the graphic below. Click Cancel to exit the window.

Page 38: Navisphere Manager Simulator Lab Guide

Populating Storage Groups 11. For FC4700-1 - SG2, select LUN 25 and place it into Selected LUNs. Click Apply, and then

confirm the operation. Exit the window by clicking Cancel.

Simulator Lab Guide Navisphere Manager

Lab pg 36

Page 39: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 37

Populating Storage Groups 12. Expand FC4700-1 – Storage Groups – SG1 – LUNs and SG2 – LUNs to verify the LUNs are in

the correct Storage Group.

Page 40: Navisphere Manager Simulator Lab Guide

Populating Storage Groups 13. For FC4700-2 SG1, Select LUNs 10, 11, 12 and 20 from the Available LUNs and move them

to Selected LUNs with the right arrow. Click Apply and then confirm the operation. When completed, the window should look like the graphic below. Click Cancel to exit the window.

Simulator Lab Guide Navisphere Manager

Lab pg 38

Page 41: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 39

Populating Storage Groups 14. For FC4700-2 SG2, select LUN 30 and place it into Selected LUNs. Click Apply, and then

confirm the operation. Exit the window by clicking Cancel.

Page 42: Navisphere Manager Simulator Lab Guide

Populating Storage Groups 15. Expand FC4700-2 – Storage Groups – SG1 – LUNs and SG2 – LUNs to verify the LUNs are in

the correct Storage Group.

16.

This completes the Populating Storage Groups Exercise

Simulator Lab Guide Navisphere Manager

Lab pg 40

Page 43: Navisphere Manager Simulator Lab Guide

Lab 6: Mirroring between Two CLARiiON Storage Arrays These steps will illustrate the procedure to mirror LUNs on two CLARiiON Storage Systems. Mirroring allows copying of a LUN to another Storage System insuring that the data will be available in case of a Disaster. Mirroring between Two CLARiiON Storage Systems 1. To Mirror a LUN between FC4700-1 and FC4700-2, pick FC4700-2 as the Primary (source) LUN

Storage and FC4700-1 as the Secondary (target) LUN Storage. Right-click on FC4700-2 and select MirrorView, Create Remote Mirror.

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 41

Page 44: Navisphere Manager Simulator Lab Guide

Mirroring between Two CLARiiON Storage Systems 2. Enter the following information into the FC4700-2 Create Remote Mirror Window:

Name: ExchMirror Description: Exchange Data Mirror Primary Storage System LUN to be Mirrored: LUN 10 Quiesce Threshold is fixed at 60 Select Apply and confirm the operation

Simulator Lab Guide Navisphere Manager

Lab pg 42

Page 45: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 43

Mirroring between Two CLARiiON Storage Systems 3. At this time, you have a mirror Primary Image with no Secondary Image. This explains the

Attention state of the Mirror. Next add the Secondary Image (LUN).

Page 46: Navisphere Manager Simulator Lab Guide

Mirroring between Two CLARiiON Storage Systems 4. To add the Secondary Image, right-click on the Mirror object, ExchMirror, and select Add

Secondary Image.

Simulator Lab Guide Navisphere Manager

Lab pg 44

Page 47: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 45

Mirroring between Two CLARiiON Storage Systems 5. Choose FC4700-1 as the Secondary Storage System then select LUN 10 from the Select

Secondary Mirror Image LUN listing. Click Apply and then confirm the operation. Click Cancel to exit the window.

Page 48: Navisphere Manager Simulator Lab Guide

Mirroring between Two CLARiiON Storage Systems 6. Using the Enterprise Storage Window, confirm the mirror creation and components.

7.

This completes the Mirroring between Two CLARiiON Storage Systems exercise.

Simulator Lab Guide Navisphere Manager

Lab pg 46

Page 49: Navisphere Manager Simulator Lab Guide

Lab 7: Creating a SnapView Clone SnapView Clones are typically used to facilitate Disk-Based Backups in a Production environment. Clones ease the overall performance “Hit” when backing up a LUN in a 24 by 7 production environment. Clones also allow for faster recovery when the original data is not accessible. Creating a SnapView Clone 1. The first step is to create a Clone Group where the Clone will be a member. Right-click on the

FC4700-1 array and select SnapView then select Create Clone Group.

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 47

Page 50: Navisphere Manager Simulator Lab Guide

Creating a SnapView Clone 2. In the name field enter the name of the Clone Group, Clone_group1 and select LUN 10 in the

“LUN to be Cloned” field. Click Apply and confirm the operation.

Simulator Lab Guide Navisphere Manager

Lab pg 48

Page 51: Navisphere Manager Simulator Lab Guide

Creating a SnapView Clone 3. To place a Clone LUN in a Clone Group, expand SnapView – Clones. Right-click on the

Clone_group1 and select Add Clone.

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 49

Page 52: Navisphere Manager Simulator Lab Guide

Creating a SnapView Clone 4. In the Add Clone window choose LUN 25 as your Clone LUN. Check Use Protected Restore

and select a Medium Synchronization Rate as shown in the graphic below. Select Apply then confirm the operation. Select Cancel to exit the window.

Simulator Lab Guide Navisphere Manager

Lab pg 50

Page 53: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 51

Creating a SnapView Clone 5. To review the Clone Creation, expand SnapView – CloneS – Clone_group1 –

0100000000000000, the Clone ID number in the Clone group1. This will show you the LUN used as a Clone, as shown in the graphic below.

6. This completes the Creating a SnapView Clone Exercise

Page 54: Navisphere Manager Simulator Lab Guide

Lab 8: Creating SnapView SnapShots Follow these steps to complete the configuration of both SP-A and SP-B properties. NOTE: You cannot manage a Storage Processor using a serial cable connection and Ethernet connection at the same time. Creating SnapView SnapShots 1. First we will add a SnapShot to the Clone LUN. Select the Clone LUN from the previous

operation and right –click to get the drop-down menu. Select Create SnapShot.

Simulator Lab Guide Navisphere Manager

Lab pg 52

Page 55: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 53

Creating SnapView SnapShots 2. In the Create SnapShot window, give the SnapShot a name, SQL_Clone, and assign the

SnapShot to Storage Group SG2. Assigning the SnapShot to SG2 gives Seawin-41 access to the SnapShot LUN (when the SnapShot is active) for backup purposes. Select Apply and confirm the operation

Page 56: Navisphere Manager Simulator Lab Guide

Creating SnapView SnapShots 3. Review the SnapShot creation in the Enterprise Storage Window under SnapView – Clones as

shown below.

Simulator Lab Guide Navisphere Manager

Lab pg 54

Page 57: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 55

Creating SnapView SnapShots 4. To create a SnapShot on a regular LUN, expand the SP of the LUN and select the LUN to be

Snapped; as shown in the graphic, expand FC4700-2 then SPB. Right-click on the LUN 20 and select Create SnapShot.

Page 58: Navisphere Manager Simulator Lab Guide

Creating SnapView SnapShots 5. As with the previous SnapShot, give the SnapShot a Name and select a Storage Group. Try to

give the SnapShot a name that will describe its function. Select Apply and confirm the operation.

Simulator Lab Guide Navisphere Manager

Lab pg 56

Page 59: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 57

Creating SnapView SnapShots 6. Once the SnapShot is created, it can be placed in a Session. The point in time is set when the

session is started. To start a session, right-click on the SnapShot LUN, LUN 20, and select SnapView, Start SnapView Session.

Page 60: Navisphere Manager Simulator Lab Guide

Creating SnapView SnapShots 7. Give the session a name, ExchLogBU, and select the LUN to be included in the session from

Available Source LUN(s). Click OK to start the session and set the point in time for the SnapCopy LUN. Remember, when you start the session, the point in time of the SnapCopy LUN is set and SnapCache is collecting the Copy on First Write data.

Simulator Lab Guide Navisphere Manager

Lab pg 58

Page 61: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager Simulator

Lab pg 59

Creating SnapView SnapShots 8. Review the session creation by expanding the SnapView – SnapShot Sessions object in the

Enterprise Storage Window

9. You have now configured your CLARiiON Storage System for Host access to RAID protected

LUNs. You have Mirror protected an essential data LUN to another CLARiiON. You have Cloned a LUN to allow for faster Backups. And, you are using SnapShots on two LUNs to ease the Backup operation on your production environment. Congratulations on your accomplishment!

10. You have completed the CLARiiON Manager Configuration LAB

Page 62: Navisphere Manager Simulator Lab Guide

Summary In this lab, you used Navisphere Manager to configure two CLARiiON Storage Systems. In the process of implementing the configuration you: • Configured RAID Groups on two CLARiiON Storage Systems to allow for binding

LUNs of a particular RAID type • Bound LUNs on the new RAID Groups to create disk resources for the host computers

and implement the RAID protection for data • Populated Storage Groups with host computer and LUNs to allow the host computers

access to disk resources create on the CLARiiON Storage Systems • Created a Mirror between two CLARiiON Storage Systems to protect data from one

CLARiiON LUN to a LUN on another CLARiiON Storage System • Created a Clone within one of the CLARiiON Storage Systems to allow for easy backup

of the data without impacting the production LUN’s performance • Created SnapShots for multiple LUNs to facilitate easy backups without the high

resource overhead required by Mirrors or Clones • Started a Snap Session for one of the SnapShots to set the point in time for the snapped

data

Simulator Lab Guide Navisphere Manager

Lab pg 60

Page 63: Navisphere Manager Simulator Lab Guide

Assessment Questions Please answer the following questions. When creating a RAID Group, what are you doing to the disks involved? 1. Changing the domain name. 2. Creating a disk group that can be bound into a specific RAID Type using the Bind

LUN process. 3. Selecting the domain RAID settings to allow the Storage System to vary the RAID

information sent to the Management GUI at shortened intervals. 4. Configuring SP-A and SP-B exclusive RAID type settings. What process will create a disk resource for a Host? 1. Bind a LUN 2. Create a Clone Group 3. Create a Mirror Secondary 4. Create SnapCache The Host Computer is typically placed into a single Storage Group? True False Which of the following is correct when creating a Mirror between two CLARiiON Storage Systems? 1. The CLARiiON Storage Systems must be the same model 2. The CLARiiON Storage Systems must have the same number of disks installed 3. The Secondary LUN must not be placed in a Storage Group 4. The Primary LUN must not be placed in a Storage Group

Navisphere Manager Simulator Lab Guide

Lab pg 61

Page 64: Navisphere Manager Simulator Lab Guide

Simulator Lab Guide Navisphere Manager

Lab pg 62

This page is blank