35
N Surge Protection FAIL-SAFE OVERVOLTAGE PROTECTION IN A FULL RANGE OF OPTIONS • Surge-Trap® STZ Series N2 • Surge-Trap® STZ-R Series N5 • Surge-Trap® STXH Series N8 • Surge-Trap® STXR Series N10 • Surge-Trap® STXP Series N12 • Surge-Trap® STXT Series N14 • Surge-Trap® STT Series N16 • Surge-Trap® STP Series Pluggable SPD N19 • Surge-Trap® ST Series Modular SPD N22 • Surge-Trap® STPT2-PV Series for Photovoltaic N25 • Surge-Trap® STMT23 Slim Series (IEC only) N26 • Surge-Trap® STET23 Series with EMI Filter (IEC only) N27 • STLB Series N28 • TPMOV® Technology N30 • VSP MOV Protector Fuse N32 • Surge-Rated Disconnect Switch N34 Your problem: Power-related problems cost US companies more than $80 billion dollars a year Most transients originate from within a facility and nearly 80% of today’s overvoltage problems are caused by equipment and power disturbances within the plant These inner-facility transients are caused, for example, by light load panels switching on and off, motors starting and stopping, and close conductor proximity Less than 20% of the transient problems originate outside the facility due to lightning strikes, utility grid switching, switching capacitor banks, and electrical accidents Our solution: You need fail-safe surge suppression, and the reliability and cost savings of Mersen’s Surge-Trap® Surge Protective Devices with patented TPMOV® Technology inside Surge-Trap SPDs provide a compact, space saving solution Plus, unlike other SPDs on the market, they do not require additional overcurrent protection, thus offering reduced installation costs Want more information fast? For more technical or application-specific information, please call our overvoltage protection experts at 978-462-6662; 416-252-9371 in Canada; or visit our website at ep.mersen.com.

N Surge Protection

Embed Size (px)

Citation preview

Page 1: N Surge Protection

NSurge ProtectionFA I L- S A F E OV E R VO LTAG E P R OT E C T I O N I N A F U L L R A N G E O F O P T I O N S

• Surge-Trap® STZ Series . . . . . . N2

• Surge-Trap® STZ-R Series . . . . N5

• Surge-Trap® STXH Series . . . . . N8

• Surge-Trap® STXR Series . . . . N10

• Surge-Trap® STXP Series . . . . N12

• Surge-Trap® STXT Series . . . . N14

• Surge-Trap® STT Series . . . . . . N16

• Surge-Trap® STP Series Pluggable SPD . . . . . . . . . . . . . N19

• Surge-Trap® ST Series Modular SPD . . . . . . . . . . . . . . . N22

• Surge-Trap® STPT2-PV Series for Photovoltaic . . . . . . . . . . . N25

• Surge-Trap® STMT23 Slim Series (IEC only) . . . . . . . . . . . . . . . . . N26

• Surge-Trap® STET23 Series with EMI Filter (IEC only) . . . . N27

• STLB Series . . . . . . . . . . . . . . . . N28

• TPMOV® Technology . . . . . . . . N30

• VSP MOV Protector Fuse . . . . N32

• Surge-Rated Disconnect Switch . . . . . . . . . . N34

Your problem: Power-related problems

cost U .S . companies more than $80 billion

dollars a year . Most transients originate

from within a facility and nearly 80% of

today’s overvoltage problems are caused

by equipment and power disturbances

within the plant . These inner-facility

transients are caused, for example, by

light load panels switching on and off,

motors starting and stopping, and close

conductor proximity . Less than 20% of the

transient problems originate outside the

facility due to lightning strikes, utility grid

switching, switching capacitor banks, and

electrical accidents .

Our solution: You need fail-safe surge

suppression, and the reliability and

cost savings of Mersen’s Surge-Trap®

Surge Protective Devices with patented

TPMOV® Technology inside . Surge-Trap

SPDs provide a compact, space saving

solution . Plus, unlike other SPDs on the

market, they do not require additional

overcurrent protection, thus offering

reduced installation costs .

Want more information fast? For

more technical or application-specific

information, please call our overvoltage

protection experts at 978-462-6662;

416-252-9371 in Canada; or visit our

website at ep.mersen.com.

Page 2: N Surge Protection

EP.MERSEN.COMN2

SURGE PROTECTIVE DEVICE

NEMA DEVICES FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® STZ SERIESEXTERNAL SPD

The Mersen flagship for facility-wide protection, The Surge-Trap®

Type 1 STZ Series features surge capacities up to 450kA designed

with Mersen’s industry leading TPMOV® technology inside making it

the safest and most reliable product on the market . Options include

surge counter, through-the-door disconnect switch, audible alarm, dry

contact, and EMI/RFI filtering . This external SPD can be installed on

the line or load side of the service entrance .

F E AT U R E S A N D B E N E F I T S :• Ideal for new construction bid projects and specification as well as

existing facility retrofit

• Available with accessory Option A for basic features (LED status

indicators) and Option B for standard features (EMI/RFI filter,

surge counter, Audible alarm and dry contacts)

• Replaceable SPD Module which can be rotated 90 degrees

depending on desired cable entry location

• Up to 10 Modes of Protection (L-N, L-L, L-G, N-G)

• 15-year warranty

R AT I N G S :

• Volts (Un): 120-480VAC

• Nominal Discharge Current Rating (In): 20kA

• Surge Capacity (per phase): 100, 150, 200, 300, 450kA

• Short-Circuit Current Rating (SCCR): 200kA

• Optional EMI/RFI Filter: Up to

-50dB from 10kHz to 100MHz

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 SPD, File E210793

• CSA C22 .2, Type 1 SPD

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• UL96A Lightning Protection

• RoHS Compliant

Page 3: N Surge Protection

EP.MERSEN.COM N3

SURGE PROTECTIONSURGE-TRAP® STZ SERIES

GENERAL PRODUCT SPECIFICATIONS

CATALOG NUMBER (INCLUDES SUFFIXES*)

SYSTEM VOLTAGE AND CONFIGURATION

In MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, Uc)

VOLTAGE PROTECTION RATING (VPR) (UL 1449, 6kA, 3kV)

L-N L-G L-L N-G* L-N L-G L-L N-G*STZ240S… 240/120V Split Phase 20kA 150 150 300 150 700 700 1000 700

STZ120D… 120V 3-Phase DELTA 20kA - 150 300 - - 700 1000 -

STZ208Y… 208/120V 3-Phase WYE 20kA 150 150 300 150 700 700 1000 700

STZ480Y… 480/277V 3-Phase WYE 20kA 320 320 640 150 1200 1200 2000 700

STZ240D… 240V 3-Phase DELTA 20kA - 320 640 - - 1200 2000 -

STZ480D… 480V 3-Phase DELTA & HRG WYE 20kA - 550 1100 - - 1800 3000 -

*Part Number Selector (Don’t see what you need? Please contact the factory)

STZModel Series

STZ

480YVoltage and System

Configuration

240S: 240/120V Split120D: 120V DELTA208Y: 208/120V WYE480Y: 480/277V WYE240D: 240V DELTA480D: 480V DELTA & HRG WYE

30Surge Capacity

10: 100kA15: 150kA20: 200kA30: 300kA45: 450kA

BPackage

A: Basic LED Status Indicators Phase Loss IndicationB: Standard LED Status Indicators Phase Loss Indication Audible Alarm Form C Dry Contacts EMI/RFI Filter Surge Counter

1Enclosure

1: NEMA 1/12/3R/4X: NEMA 4X

TDisconnect

T: UL98 Switch thru the door handleBLANK: None

Human-Machine Interface (HMI)

Option A: Basic Option B: Standard

Note: Images above show HMI mounted on Internal SPD (STZ-R Series). For the STZ External SPD, HMI will be mounted on the enclosure door.

Mounting: Mounting feetWiring: Wire Lugs for 6-10 AWG copperEnclosure: NEMA 4 or NEMA 4X stainless steelFlammability: UL94-5VA Operating & Storage Temperature: -40°C to +85°C

Relative Humidity Range: 0 to 95% non-condensingVisual LED End-of-Life Indicator: Green = 67 to 100% Life Yellow = 34 to 66% Life Red = 0 to 33% LifeFrequency: 50-60Hz

Page 4: N Surge Protection

EP.MERSEN.COMN4

SURGE PROTECTION SURGE-TRAP® STZ SERIES

Optional Form C Dry Contact and Audible Alarm (Included with Option B)

Form C Dry Contact 125VAC, 1A Resistive 30VDC, 2A General Purpose __________________________________________________

COM = Common NO = Normally Open NC = Normally Closed

Audible Alarm Alarm sounds when any protection is lost.

Dimensions and Mounting Configurations

Without Disconnect Switch 12x12 Enclosure

With Disconnect Switch16x12 Enclosure

DIMENSIONS IN [ ] ARE MILLIMETERS

6.29 12.98

13.52

10.00

12.77

4X .31 THRU

REV. DATE ECO DESCRIPTION BY CK APP- 3/2/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STZ SeriesExternal SPD Type 1

NEMA 4/4X450kA max Surge Capacity

C. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

7021143/2/16

DIMENSIONS IN [ ] ARE MILLIMETERS

12.98

17.52

8.06 12.00

16.77

4X .31 THRU

REV. DATE ECO DESCRIPTION BY CK APP- 3/2/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STZ SeriesExternal SPD Type 1

NEMA 4/4X with Disconnect Switch450kA max Surge Capacity

C. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

7021153/2/16

Page 5: N Surge Protection

EP.MERSEN.COM N5

SURGE PROTECTIVE DEVICE

NEMA DEVICES FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® STZ-R SERIESINTERNAL SPD

For facility-wide surge protection internal to existing equipment such

as switchgear, panelboards, or motor control centers, the Surge-Trap®

Type 1 STZ-R Series is the obvious choice . The STZ-R series features

surge capacities up to 450kA designed with Mersen’s industry-leading

TPMOV® technology inside making it the safest and most reliable

product on the market . Ideal for OEMs and panel builders, this internal

SPD can be installed on the line or load side of the service entrance .

F E AT U R E S A N D B E N E F I T S :• SPD intended to be installed internal to existing switchgear,

panelboards, motor control centers, etc .

• Available with accessory Option A for basic features (LED status

indicators) and Option B for standard features (EMI/RFI filter,

surge counter, Audible alarm and dry contacts)

• Local or remote human machine interface (HMI) which can be

rotated 90 degrees depending on desired cable entry location

• Up to 10 Modes of Protection (L-N, L-L, L-G, N-G)

• 15-year warranty

R AT I N G S :

• Volts (Un): 120-480VAC

• Nominal Discharge Current Rating (In): 20kA

• Surge Capacity (per phase): 100, 150, 200, 300, 450kA

• Short-Circuit Current Rating (SCCR): 200kA

• Optional EMI/RFI Filter: Up to

-50dB from 10kHz to 100MHz

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 SPD, File E210793

• CSA C22 .2, Type 1 SPD

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• UL96A Lightning Protection

• RoHS Compliant

Page 6: N Surge Protection

EP.MERSEN.COMN6

SURGE PROTECTION SURGE-TRAP® STZ-R SERIES

GENERAL PRODUCT SPECIFICATIONS

CATALOG NUMBER (INCLUDES SUFFIXES*)

SYSTEM VOLTAGE AND CONFIGURATION

In MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, Uc)

VOLTAGE PROTECTION RATING (VPR) (UL 1449, 6kA, 3kV)

L-N L-G L-L N-G* L-N L-G L-L N-G*STZ240S… 240/120V Split Phase 20kA 150 150 300 150 700 700 1000 700

STZ208Y… 208/120V 3-Phase WYE 20kA 150 150 300 150 700 700 1000 700

STZ480Y… 480/277V 3-Phase WYE 20kA 320 320 640 150 1200 1200 2000 700

STZ120D... 120V 3-Phase DELTA 20kA - 150 300 - - 700 1000 -

STZ240D… 240V 3-Phase DELTA 20kA - 320 640 - - 1200 2000 -

STZ480D… 480V 3-Phase DELTA & HRG WYE 20kA - 550 1100 - - 1800 3000 -

*Part Number Selector (Don’t see what you need? Please contact the factory.)

STZModel Series

STZ

480YVoltage and System

Configuration

240S: 240/120V Split120D: 120V DELTA208Y: 208/120V WYE480Y: 480/277V WYE240D: 240V DELTA480D: 480V DELTA & HRG WYE

30Surge Capacity

10: 100kA15: 150kA20: 200kA30: 300kA45: 450kA

BPackage

A: Basic LED Status Indicators Phase Loss IndicationB: Standard LED Status Indicators Phase Loss Indication Audible Alarm Form C Dry Contacts EMI/RFI Filter Surge Counter

REnclosure

Q: Internal SPD without HMIR: Internal SPD with HMI

UDisconnect

U: UL98 SwitchBLANK: None

Human-Machine Interface (HMI)

Option A: Basic Option B: Standard

Mounting: Mounting feetWiring: Wire Lugs for 6-10 AWG copperFlammability: UL94-5VA Operating & Storage Temperature: -40°C to +85°C

Relative Humidity Range: 0 to 95% non-condensingVisual LED End-of-Life Indicator: Green = 67 to 100% Life Yellow = 34 to 66% Life Red = 0 to 33% LifeFrequency: 50-60Hz

Page 7: N Surge Protection

EP.MERSEN.COM N7

SURGE PROTECTIONSURGE-TRAP® STZ-R SERIES

Optional Form C Dry Contact and Audible Alarm (Included with Option B)

Form C Dry Contact 125VAC, 1A Resistive 30VDC, 2A General Purpose __________________________________________________

COM = Common NO = Normally Open NC = Normally Closed

Audible Alarm Alarm sounds when any protection is lost.

Dimensions and Mounting Configurations

Without Disconnect Switch With Disconnect Switch12x12 Enclosure 16x12 Enclosure

DIMENSIONS IN [ ] ARE MILLIMETERS

2.49

4.83

3.98

.70

TYP. .900

TYP. .500

TYP. .080

8.47 5.50 2.00

8.31

7.75

8X .25 THRU

REV. DATE ECO DESCRIPTION BY CK APP- 3/1/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STZ-R SeriesInternal SPD Type 1

450kA max Surge CapacityC. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

7021133/2/16

DIMENSIONS IN [ ] ARE MILLIMETERS

10.88

10.25

5.60

14.75 14.25

4.45

4X .25 THRU

11.01

4.98

4.05

REV. DATE ECO DESCRIPTION BY CK APP- 3/2/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STZ-R SeriesInternal SPD Type 1 with Disconnect Switch

450kA max Surge CapacityC. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

7021163/2/16

DIMENSIONS IN [ ] ARE MILLIMETERS

10.88

10.25

5.60

14.75 14.25

4.45

4X .25 THRU

11.01

4.98

4.05

REV. DATE ECO DESCRIPTION BY CK APP- 3/2/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STZ-R SeriesInternal SPD Type 1 with Disconnect Switch

450kA max Surge CapacityC. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

7021163/2/16

DIMENSIONS IN [ ] ARE MILLIMETERS

2.49

4.83

3.98

.70

TYP. .900

TYP. .500

TYP. .080

8.47 5.50 2.00

8.31

7.75

8X .25 THRU

REV. DATE ECO DESCRIPTION BY CK APP- 3/1/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STZ-R SeriesInternal SPD Type 1

450kA max Surge CapacityC. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

7021133/2/16

DIMENSIONS IN [ ] ARE MILLIMETERS

10.88

10.25

5.60

14.75 14.25

4.45

4X .25 THRU

11.01

4.98

4.05

REV. DATE ECO DESCRIPTION BY CK APP- 3/2/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STZ-R SeriesInternal SPD Type 1 with Disconnect Switch

450kA max Surge CapacityC. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

7021163/2/16

Page 8: N Surge Protection

EP.MERSEN.COMN8

SURGE PROTECTIVE DEVICE

NEMA DEVICES FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® STXH SERIES

The most compact of the STX series offering, the Surge-Trap®

Type 1 STXH meets requirements for UL1449 4th Edition and is

suitable for any 120/240VAC split phase application . The STXH Series

SPD features TPMOV® technology inside making it the safest product

available in its category . Its compact size, performance, and reliability

are especially ideal for HVAC applications and direct mounting to air

condition disconnect switches .

F E AT U R E S A N D B E N E F I T S :

• Designed with the industry leading Mersen TPMOV® Technology

• Compact footprint designed to mate with AC Disconnect Switches

• LED status indicator (ON = Good, OFF = Replace)

• NEMA 4X enclosure for outdoor or indoor use

• Fits 1/2" knockouts with 18" leads for easy installation

• For use in ANSI/UL Type 1 or 2 SPD installations

• 3 Modes of Protection (L-N, L-L)

• 3-year warranty

R AT I N G S :

• Volts (Un): 120V Single Phase,

120/240VAC Split Phase

• Nominal Discharge Current Rating (In): 20kA

• Surge Capacity (per phase and per mode): 50kA

• Short-Circuit Current Rating (SCCR): 200kA

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 SPD, File E210793

• CSA C22 .2, Type 1 SPD

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• UL96A Lightning Protection

• RoHS Compliant

Page 9: N Surge Protection

EP.MERSEN.COM N9

SURGE PROTECTIONSURGE-TRAP® STXH SERIES

GENERAL PRODUCT SPECIFICATIONS

CATALOG NUMBER (INCLUDES SUFFIXES*)

SYSTEM VOLTAGE AND CONFIGURATION

In MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, Uc)

VOLTAGE PROTECTION RATING (VPR) (UL 1449, 6kA, 3kV)

L-N L-G L-L N-G L-N L-G L-L N-GSTXH120P05 120V Single Phase (2W) 20kA 150 - - - 600 - - -

STXH120P05N 120V Single Phase (2W+G) 20kA 150 300 - 150 600 1000 - 600

STXH240S05 240/120V Split Phase (3W) 20kA 150 - 300 - 600 - 1000 -

LED Status Indicator 1/2"-14 Mounting Hub

Dimensions and Mounting Configurations Ideal for Air Conditioning Disconnect Applications

Mounting: 1/2" – 14 threaded hub Includes sealing locking washerWiring: Pre-wired 18" 10AWGEnclosure: NEMA 4X Non-metallicFlammability: UL94-5VA

Operating & Storage Temperature: -40°C to +85°CRelative Humidity Range: 0 to 95% non-condensingVisual End-of-Life Indicator: GREEN = OK, OUT = REPLACEFrequency: 50-60Hz

Visible from side profile through light tube in cover

DIMENSIONS IN [ ] ARE MILLIMETERS

3.07 21.00±2.00

.88

.13

1/2 NPSM

1/2 SEALING LOCKNUT

10 AWG WIRES

1.85

3.22

REV. DATE ECO DESCRIPTION BY CK APP- 2/29/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STXH SeriesSurge-Trap® SPD Type 1

3/2/16

C. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

702103

DIMENSIONS IN [ ] ARE MILLIMETERS

3.07 21.00±2.00

.88

.13

1/2 NPSM

1/2 SEALING LOCKNUT

10 AWG WIRES

1.85

3.22

REV. DATE ECO DESCRIPTION BY CK APP- 2/29/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STXH SeriesSurge-Trap® SPD Type 1

3/2/16

C. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

702103

Page 10: N Surge Protection

EP.MERSEN.COMN10

SURGE PROTECTIVE DEVICE

NEMA DEVICES FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® STXR SERIES

The most popular range in the STX series offering, the Surge-Trap®

Type 1 STXR meets requirements for UL1449 4th Edition and is ideal

for the replacement of obsolete surge arrestors . The STXR Series SPDs

feature TPMOV® technology inside, making them the safest product

available . With a small, compact design and line or load installation

flexibility, the STXR series is the perfect fit for branch panel and/or

individual equipment protection .

F E AT U R E S A N D B E N E F I T S :

• Designed with the industry leading Mersen TPMOV® Technology• LED status indicator (ON = Good, OFF = Replace)• NEMA 4X enclosure for outdoor or indoor use• Fits 3/4" knockouts with 3' leads for easy installation• Optional mounting bracket for surface mount applications• Optional audible alarm and remote dry contacts• For use in ANSI/UL Type 1 or 2 SPD installations• Up to 10 modes of Protection (L-N, L-L, L-G optional, N-G optional)

• 5-year warranty

R AT I N G S :

• Volts (Un): 120-600VAC

• Nominal Discharge Current Rating (In): 10-20kA

• Surge Capacity (per phase and per mode): 50kA

• Short-Circuit Current Rating (SCCR): 200kA

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 SPD, File E210793

• CSA C22 .2, Type 1 SPD

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• UL96A Lightning Protection

• RoHS Compliant

Page 11: N Surge Protection

EP.MERSEN.COM N11

SURGE PROTECTIONSURGE-TRAP® STXR SERIES

GENERAL PRODUCT SPECIFICATIONS

CATALOG NUMBER (INCLUDES SUFFIXES*)

SYSTEM VOLTAGE AND CONFIGURATION

In MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, Uc)

VOLTAGE PROTECTION RATING (VPR) (UL 1449, 6kA, 3kV)

L-N L-G L-L N-G* L-N L-G L-L N-G*STXR120P05 120V Single Phase 20kA 150 300 - 150 700 1200 - 600

STXR240P05 240V Single Phase 20kA 320 640 - 320 1200 1800 - 1000

STXR240S05 240/120V Split Phase 20kA 150 300 300 150 700 1200 1200 600

STXR480S05 480/240V Split Phase 20kA 320 640 640 320 1200 1800 2000 1000

STXR208Y05 208/120V 3-Phase WYE 20kA 150 300 300 150 700 1200 1200 600

STXR380Y05 380/220V 3-Phase WYE 20kA 320 640 640 320 1200 1800 2000 1000

STXR480Y05 480/277V 3-Phase WYE 20kA 320 470 640 150 1200 1800 2000 700

STXR600Y05 600/347V 3-Phase WYE 20kA 420 690 840 270 1500 2500 2500 1000

STXR240D05 240V 3-Phase DELTA 20kA - 320 640 - - 1200 2000 -

STXR480D05 480V 3-Phase DELTA & HRG WYE 10kA - 550 1100 - - 1800 3000 -

STXR600D05 600V 3-Phase DELTA 20kA - 690 840 - - 2000 2500 -

L-N/HL-N

L-G/HL-G

L-L/HL-L

N-G* L-N/HL-N

L-G/HL-G

L-L/HL-L

N-G*

STXR240H05 240/120V Hi-Leg DELTA 20kA 150/270 300/420 300/420 150 700/1.2k 1.2k/1.2k 2k/2k 600

STXR480H05 480/240V Hi-Leg DELTA 10kA 320/550 320/550 640/870 320 1.2/1.8k 1.2/1.8k 2k/2.5k 1000

*Suffixes: Add Suffix “N” for N-G protection. Example: STXR208Y05N

Add Suffix “A” for Audible Alarm and Dry Contact. Example: STXR208Y05A

For both options, Example: STXR208Y05AN

CATALOG NUMBER

ACCESSORY DESCRIPTION

STXRMBK STXR Mounting Bracket Kit. Includes (1) 90 degree bracket and (2) mounting screws

Optional Form C Dry Contact and Audible Alarm (Suffix “A”)

Form C Dry Contact (Pre-wired 3' 18AWG) 125VAC, 1A Resistive 30VDC, 2A General Purpose __________________________________________________

Gray = Normally Closed Blue = Common Red = Normally Open

Audible AlarmAlarm sounds when any protection is lost

3/4"-14 Mounting Hub

Dimensions and Mounting Configurations Bracket Mount Option

Mounting: 3/4" – 14 threaded hub Includes locking washerWiring: Pre-wired 3' (1m) 10AWGEnclosure: NEMA 4X Non-metallicFlammability: UL94-5VA

Operating & Storage Temperature: -40°C to +85°CRelative Humidity Range: 0 to 95% non-condensingVisual End-of-Life Indicator: GREEN = OK, OUT = REPLACEFrequency: 50-60Hz

Page 12: N Surge Protection

EP.MERSEN.COMN12

SURGE PROTECTIVE DEVICE

NEMA DEVICES FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® STXP SERIES

The Surge-Trap® Type 1 STXP Series offers advanced performance and

features over the STXR series including higher surge capacity and

phase LED status indicators . The STXP meets requirements for UL1449

4th Edition and has been designed for additional mounting flexibility

including mounting feet and flush-mount capability . The STXP features

TPMOV® technology inside making it the safest product available .

Installation can be done on the line or load side of a panel . The STXP is

the perfect fit from service entrance all the way down to an important

machine specific control panel .

F E AT U R E S A N D B E N E F I T S :• Designed with the industry leading Mersen TPMOV® Technology

(internally fused)

• Enhanced 100kA surge capacity for longer life and higher single

impulse withstand

• Pre-wired with 3' leads for easy installation

• Up to 10 Modes of Protection (L-N, L-L, L-G, N-G)

• 10-year warranty

R AT I N G S :

• Volts (Un): 120-600VAC

• Nominal Discharge Current Rating (In): 20kA

• Surge Capacity (per phase): 100kA

• Short-Circuit Current Rating (SCCR): 200kA

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 SPD, File E210793

• CSA C22 .2, Type 1 SPD

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• UL96A Lightning Protection

• RoHS Compliant

Page 13: N Surge Protection

EP.MERSEN.COM N13

SURGE PROTECTIONSURGE-TRAP® STXP SERIES

GENERAL PRODUCT SPECIFICATIONS

CATALOG NUMBER (INCLUDES SUFFIXES*)

SYSTEM VOLTAGE AND CONFIGURATION

In MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, Uc)

VOLTAGE PROTECTION RATING (VPR) (UL 1449, 6kA, 3kV)

L-N L-G L-L N-G* L-N L-G L-L N-G*STXP120P10 120V Single Phase 20kA 150 150 - 150 700 700 - 600

STXP240P10 240V Single Phase 20kA 320 320 - 150 1200 1200 - 700

STXP240S10 240/120V Split Phase 20kA 150 150 300 150 700 700 1000 600

STXP480S10 480/240V Split Phase 20kA 320 320 640 150 1200 1200 2000 600

STXP208Y10 208/120V 3-Phase WYE 20kA 150 150 300 150 700 700 1000 600

STXP380Y10 380/220V 3-Phase WYE 20kA 320 320 640 150 1200 1200 2000 600

STXP480Y10 480/277V 3-Phase WYE 20kA 320 320 640 150 1200 1200 2000 600

STXP600Y10 600/347V 3-Phase WYE 20kA 420 420 840 275 1200 1500 2000 1000

STXP240D10 240V 3-Phase DELTA 20kA - 320 640 - - 1200 2000 -

STXP480D10 480V 3-Phase DELTA & HRG WYE 20kA - 550 1100 - - 1800 3000 -

STXP600D05 (50kA) 600V 3-Phase DELTA 20kA - 690 695 - - 2000 2500 -

STXP480B10 480V B Corner Ground DELTA 20kA - 550 1100 - - 1800 3000 -

L-N/HL-N

L-G/HL-G

L-L/HL-L

N-G* L-N/HL-N

L-G/HL-G

L-L/HL-L

N-G*

STXP240H10 240/120V Hi-Leg DELTA 20kA 150/275 150/275 300/425 150 700/1.2k 700/1.2k 1.0k/2000 600

STXP480H10 480/240V Hi-Leg DELTA 20kA 320/550 320/550 640/870 320 1.2k/1.8k 1.2k/1.8k 1.8k/2.5k 1000

*Suffixes: Add Suffix “A” for Audible Alarm and Dry Contact. Example: STXP208Y10A

CATALOG NO. ACCESSORY DESCRIPTIONSTXPFMK STXP Flush Mount Kit. Includes (1) mounting plate and (3) mounting screws

Optional Form C Dry Contact and Audible Alarm (Suffix “A”)

Form C Dry Contact (Pre-wired 3' 18AWG) 125VAC, 1A Resistive 30VDC, 2A General Purpose __________________________________________________

Gray = Normally Closed Blue = Common Red = Normally Open

Audible AlarmAlarm sounds when anyprotection is lost

Dimensions and Mounting Configurations Flush Mount Option

Mounting: Female 3/4" – 14 threaded hub Mounting feet with 0.125" diameter holesWiring: Pre-wired 3' (1m) 10AWGEnclosure: NEMA 4X Non-metallicFlammability: UL94-5VA

Operating & Storage Temperature: -40°C to +85°CRelative Humidity Range: 0 to 95% non-condensingVisual End-of-Life Indicator: GREEN = OK, OUT = REPLACEFrequency: 50-60Hz

3/4"-14 Female Mounting Hub

Page 14: N Surge Protection

EP.MERSEN.COMN14

SURGE PROTECTIVE DEVICE

NEMA DEVICES FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® STXT SERIES

The most advanced of the STX series, the Surge-Trap® Type 1 STXT

Series comes standard with EMI/RFI Filtering and surge capacities up

to 200kA . The STXT features TPMOV® technology inside, making it the

safest product available . With line or load side installation flexibility,

this unit is a great fit from the service entrance all the way down to

each distribution and/or branch panel .

F E AT U R E S A N D B E N E F I T S :• Premium 200kA surge capacity for longer life and higher single

impulse withstand

• Includes EMI/RFI filter for cleaner attenuation

• Mounting hub and mounting feet for installation flexibility

• Optional audible alarm and remote dry contacts

• Up to 10 Modes of Protection (L-N, L-L, L-G, N-G)

• 10-year warranty

R AT I N G S :

• Volts (Un): 120-600VAC

• Nominal Discharge Current Rating (In): 20kA

• Surge Capacity (per phase): 100kA or 200kA

• Short-Circuit Current Rating (SCCR): 200kA

• EMI/RFI Filter: Up to -50dB

from 10kHz to 100MHz

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 SPD, File E210793

• CSA C22 .2, Type 1 SPD

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• UL96A Lightning Protection

• RoHS Compliant

Page 15: N Surge Protection

EP.MERSEN.COM N15

SURGE PROTECTIONSURGE-TRAP® STXT SERIES

GENERAL PRODUCT SPECIFICATIONS

CATALOG NUMBER (INCLUDES SUFFIXES*)

SYSTEM VOLTAGE AND CONFIGURATION

In MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, Uc)

VOLTAGE PROTECTION RATING (VPR) (UL 1449, 6kA, 3kV)

L-N L-G L-L N-G* L-N L-G L-L N-G*

STXT120P20 120V Single Phase 20kA 150 150 - 150 700 700 - 700

STXT240P20 240V Single Phase 20kA 320 320 - 150 1200 1200 - 700

STXT240S20 240/120V Split Phase 20kA 150 150 300 150 700 700 1000 700

STXT480S20 480/240V Split Phase 20kA 320 320 640 150 1200 1200 2000 700

STXT208Y20 208/120V 3-Phase WYE 20kA 150 150 300 150 700 700 1000 700

STXT380Y20 380/220V 3-Phase WYE 20kA 320 320 640 150 1200 1200 2000 700

STXT480Y20 480/277V 3-Phase WYE 20kA 320 320 640 150 1200 1200 2000 700

STXT600Y20 600/347V 3-Phase WYE 20kA 420 420 840 275 1500 1500 2500 1200

STXT240D20 240V 3-Phase DELTA 20kA - 320 640 - - 1200 2000 -

STXT480D20 480V 3-Phase DELTA & HRG WYE 20kA - 550 1100 - - 1800 3000 -

STXT600D10 600V 3-Phase DELTA 20kA - 695 840 - - 2500 2500 -

STXT480B20 480V B Corner Ground DELTA 20kA - 550 1100 - - 1800 4000 -

L-N/HL-N

L-G/HL-G

L-L/HL-L

N-G* L-N/HL-N

L-G/HL-G

L-L/HL-L

N-G*

STXT240H20 240/120V Hi-Leg DELTA 20kA 150/275 150/275 300/425 150 700/1.2k 700/1.2k 1.0k/2000 700

STXT480H20 480/240V Hi-Leg DELTA 20kA 320/550 320/550 640/870 320 1.2k/1.8k 1.2k/1.8k 2.0k/2.5k 1200

*Suffixes: Add Suffix “A” for Audible Alarm and Dry Contact. Example: STXP208Y10A For 100kA Surge Capacity models, substitute “10” for “20.” Example: STXT208Y10

Optional Form C Dry Contact and Audible Alarm (Suffix “A”)

Form C Dry Contact 125VAC, 1A Resistive 30VDC, 2A General Purpose __________________________________________________

COM = Common NO = Normally Open NC = Normally Closed

Audible AlarmAlarm sounds when anyprotection is lost

3/4"-14 Female Mounting Hub

Dimensions and Mounting Configurations

Mounting: Female 3/4" – 14 threaded hub Mounting feet with 0.25" diameter holesWiring: Wire Lugs for 8 AWG copperEnclosure: NEMA 4X Non-metallicFlammability: UL94-5VA

Operating & Storage Temperature: -40°C to +85°CRelative Humidity Range: 0 to 95% non-condensingVisual End-of-Life Indicator: GREEN = OK, OUT = REPLACEFrequency: 50-60Hz

DIMENSIONS IN [ ] ARE MILLIMETERS

7.08

7.40

3.50

6.70

4X .30THRU

3/4 NPSMTHRU

3.68

1.25

REV. DATE ECO DESCRIPTION BY CK APP- 2/29/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STXT SeriesSurge-Trap® SPD Type 1

3/2/16

C. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

702104

DIMENSIONS IN [ ] ARE MILLIMETERS

7.08

7.40

3.50

6.70

4X .30THRU

3/4 NPSMTHRU

3.68

1.25

REV. DATE ECO DESCRIPTION BY CK APP- 2/29/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STXT SeriesSurge-Trap® SPD Type 1

3/2/16

C. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

702104

DIMENSIONS IN [ ] ARE MILLIMETERS

7.08

7.40

3.50

6.70

4X .30THRU

3/4 NPSMTHRU

3.68

1.25

REV. DATE ECO DESCRIPTION BY CK APP- 2/29/2016 N/A INITIAL RELEASE JRB N/A N/A

CONTROL No:____________1773

STXT SeriesSurge-Trap® SPD Type 1

3/2/16

C. MCKENZIE

3/2/16

R. LYONS

OUTLINE DIMENSIONSNOT TO BE USED FOR PRODUCTION

SIGN:

DATE:

DESIGN ENGINEERPRODUCT MANAGERSIGN:

DATE:

MERSEN USA NEWBURYPORT-MA, LLC374 MERRIMAC STREETNEWBURYPORT,MA 01950

SHEET 1 OF 1

702104

Page 16: N Surge Protection

EP.MERSEN.COMN16

SURGE PROTECTIVE DEVICE

NEMA DEVICES FOR ANSI/ UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® STT SERIES

The Surge-Trap® STT Series meets requirements for UL 1449 4th

Edition . It provides a two-year warranty and offers an economical

replacement for the former surge arrestor category . The Surge-Trap

Type 1 SPD features TPMOV® technology inside making it a “no-fuse”

surge suppressor that doesn’t require the use of additional overcurrent

protection . It can be installed upstream or downstream of the main

disconnect .

F E AT U R E S A N D B E N E F I T S :

• Designed with the industry leading Mersen TPMOV® Technology

• LED status indicator by phase (ON = Good, Red = Replace)

• Option for NEMA 2 or NEMA 4X enclosure for indoor or outdoor use

• NEMA 2 option fits 1/2" knockouts for panel mount

• NEMA 4X suitable for panel mount and wall mount

• For use in ANSI/UL Type 1 or 2 SPD installations

• Up to 6 modes of Protection (L-N, L-L)

• 2-year warranty

R AT I N G S :

• Volts (Un): 120-600AC

• Nominal discharge current Rating (In): 10-20kA

• Surge Capacity: 50kA per

phase

• Short-Circuit Current Rating (SCCR): 200kA

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

File E210793

• Type 1 Listed for United States

• Type 2 Listed for Canada

• RoHS Compliant

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• UL 96A Lightning Protection

Page 17: N Surge Protection

EP.MERSEN.COM N17

SURGE PROTECTIONSURGE-TRAP® STT SERIES

GENERAL PRODUCT SPECIFICATIONS

CATALOG NO. NEMA 2 ENCLOSURE

CATALOG NO. NEMA 4X ENCLOSURE

NOMINAL VOLTAGE (VAC)

SYSTEM TYPE

FREQ (HZ)

MCOV (L-N)

NOMINAL DISCHARGE CURRENT (IN, KA)

VOLTAGE PROTECTION RATING (VPR, VAC) CIRCUIT CONNECTION WIRING DIAGRAMS

L-N L-G N-G L-L

STT21201PG STT4X1201PG 120 1 50/60 180 20 700 1200 600 - A

STT2240SPG STT4X240SPG 120/240 1S 50/60 180 20 700 - - 1200 B

STT22401PG STT4X2401PG 240 1 50/60 270 20 1000 1500 700 - A

STT22083PYG STT4X2083PYG 120/208 3Y 50/60 180 20 700 - - 1200 D

STT24803PYG STT4X4803PYG 277/480 3Y 50/60 320 10 1200 - - 2000 D

STT26003PYG STT4X6003PYG 347/600 3Y 50/60 420 10 1500 - - 2500 D

STT22403PDG STT4X2403PDG 240 3D 50/60 270 (L-G) 20 - 1000 - 1800 C

STT24803PDG STT4X4803PDG 480 3D 50/60 550 (L-G) 10 - 1800 - 3000 C

DIMENSIONS: STT2

THREE PHASE SINGLE/SPLIT PHASE

DIMENSIONS: STT4X

Wiring: Pre-wired with 16" (0.4m) 12 AWG conductorsFlammability: UL94 V0Operating & Storage Temperature: -40ºC to + 85ºC

Visual End of Life Indicator: GREEN = OK RED = REPLACEFrequency: 50-60 HzResponse Time: <25 ns

3.750

4.7254.050

2.370

3.700

3.7023.002

2.370

3.750

4.7254.050

2.370

3.700

3.7023.002

2.370

4.4500.84

5.710

2.250

4.500

3.6002.43

Page 18: N Surge Protection

EP.MERSEN.COMN18

SURGE PROTECTION

Wiring Diagrams: STT2 and STT4X

Single/Split Phase

Wiring Diagrams: STT2 and STT4X

Three Phase Delta & Wye

Installation Diagram: STT2 Installation Diagram: STT4X

SURGE-TRAP® STT SERIES

A B

C D

Note: Must be installed on a solidly grounded system.

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

REV. DESCRIPTION DATE APPROVED

NUT

¾" close nipple

¾" steel conduit locking nut

nut

Page 19: N Surge Protection

EP.MERSEN.COM N19

SURGE PROTECTIVE DEVICE

DIN-RAIL PLUGGABLE SPD FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® PLUGGABLE

R AT I N G S :

• Volts (Un): 120-690VAC

• Nominal Discharge Current Rating (In): 10-20kA

• Surge Capacity: 75kA

• Short-Circuit Current Rating (SCCR): 200kA

F E AT U R E S / B E N E F I T S :• Easy installation or retrofit

• DIN-rail mountable

• Fail-safe, self-protected design

• Remote indicator

• Visual indicator

• IP20 finger-safe design

• Small footprint

• No additional overcurrent protection devices required

• Easy to replace modules

• 2-year warranty

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 Component Assembly

SPD, File E210793

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• RoHS Compliant

Surge-Trap® Pluggable Surge Protective Device (SPD) is a no-fuse,

fail-safe surge suppressor featuring Mersen’s patented TPMOV®

technology inside . UL 1449 4th Edition approved, it is DIN-rail

mountable featuring a fail-safe self-protected design, visual indicator,

and a small footprint . A remote indicator option provides status to

critical control circuitry . The Surge-Trap Pluggable SPD has a high

short circuit rating and a thermally protected MOV, which eliminates

the need for additional overcurrent protection devices .

N E W A N D I M P R OV E D 7 5 K A R AT I N G

Mersen’s DIN-Rail Pluggable SPD is one of a kind – the combination

of a robust 75kA surge capacity along with no requirement of backup

fusing creates an offering unique to the market . Add this to the

reliability and safety of Mersen’s patented TPMOV technology and you

have a truly superior product .

Page 20: N Surge Protection

EP.MERSEN.COMN20

SURGE PROTECTION SURGE-TRAP® PLUGGABLE

GENERAL PRODUCT SPECIFICATIONS

1-POLE, SINGLE-PHASE, 2-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) REPLACEMENT PLUG In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L L-1

STP120P07(M) 120 175 - - - 600 - - - SP07U175 20STP230P07(M) 240 275 - - - 600 - - - SP07U275 20STP277P07(M) 277 320 - - - 600 - - - SP07U320 20STP347P07(M) 347 420 - - - 800 - - - SP07U420 10

2-POLE, SPLIT-PHASE, 3-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) REPLACEMENT PLUG In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L L1, L2

STP240S07(M) 120/240 175 - - 350 600 - - 1800 SP07U175 20STP480S07(M) 240/480 275 - - 550 600 - - 1200 SP07U275 20

3-POLE, 3-PHASE DELTA, 4-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) REPLACEMENT PLUG In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L L1, L2, L3

STP240D07(M) 240 - 275 - 550 - 900 - 1800 SP07U275 20STP480D07(M) 480 - 550 - 1100 - 1500 - 3000 SP07U550 10

3-POLE, 3-PHASE WYE, 4-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) REPLACEMENT PLUG In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L L1, L2, L3

STP208Y07(M) 120/208 175 - - 350 600 - - 1200 SP07U175 20STP480Y07(M) 277/480 320 - - 640 1500 - - 2500 SP07U320 20STP600Y07(M) 347/600 420 - - 840 1500 - - 2500 SP07U420 10STP690Y07(M) 400/690 420 - - 840 1500 - - 2500 SP07U420 10

4-POLE, 3-PHASE WYE, 5-WIRE, INCLUDING N-G MODECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) REPLACEMENT PLUG In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L L1, L2, L3 N-G

STP208YN07(M) 120/208 175 175 175 350 600 1200 600 1200 SP07U175 SP07U175 20STP480YN07(M) 277/480 320 495 175 640 1000 1500 600 2000 SP07U320 SP07U175 20STP600YN07(M) 347/600 420 695 275 840 1500 2000 800 2500 SP07U420 SP07U275 10STP690YN07(M) 400/690 420 740 320 840 1500 2000 800 2500 SP07U420 SP07U320 10

4-POLE, 3-PHASE DELTA HIGH-LEG, 5-WIRE, INCLUDING N-G MODECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) REPLACEMENT PLUG In (kA)

L-L/L-G L-N/N-G H-L/H-G H-N L-L/L-G L-N/N-G

H-L/H-G H-N L1, L3

L2 N-G

STP240HN07(M) 120/240 350 175 450 275 1200 600 1500 800 SP07U175 SP07U275 SP07U175 20STP480HN07(M) 240/480 550/450 275/175 825/725 550 1500 800/600 2500/2000 1500 SP07U275 SP07U550 SP07U175 10

Mounting: 35mm DIN-RailWire Range: 4-14AWG Solid / Stranded CUTerminal Torque: 35.4 lbs-inDegree of Protection: IP 20Flammability: UL94 V0

Operating & Storage Temperature: – 40ºC to + 85ºCVisual End of Life Indicator: RED = End of LifeRemote End of Life Indicator: NO/NC Dry ContactFrequency: 50-60 Hz

Page 21: N Surge Protection

EP.MERSEN.COM N21

SURGE PROTECTIONSURGE-TRAP® PLUGGABLE & MODULAR

DIMENSIONS - STP SERIESPOLES A

IN MM

1 Pole 0.69 17.5

2 Pole 1.38 35

3 Pole 2.07 52.5

4 Pole 2.76 70

DIMENSIONS - ST SERIES

POLES A

IN MM

1 Pole 0.7 17.8

2 Pole 1.39 35.5

3 Pole 2.1 53.3

4 Pole 2.8 71

WIRING DIAGRAMS

1-POLE, SINGLE-PHASE, 2-WIRE

2-POLE, SPLIT-PHASE, 3-WIRE

3-POLE, 3-PHASE DELTA, 3-WIRE

3-POLE, 3-PHASE DELTA, 3-PHASE WYE, 4-WIRE

4-POLE, 3-PHASE WYE,5-WIRE

4-POLE, 3-PHASE DELTA HIGH-LEG, 5-WIRE

SINGLE PHASE 2 WIRE + GROUND

SPLIT PHASE3 WIRE + GROUND

3 PHASE DELTA3 WIRE + GROUND

3 PHASE WYE4 WIRE + GROUND

REMOTE STATUS INDICATOR

Signal Wire Range #16 to #30 AWG

Terminal Torque 2.2 lb-in

Cont. between Comm + NO Product Offline, Not Protected

Cont. between Comm + NC Product Online, Protected

ST AND STP SERIES: FOR REMOTE INDICATION, ADD “M” TO THE END OF THE CATALOG NUMBER. FOR EXAMPLE, ST4803PYGM.

NO 1

Common 2

NC

Subminiature Switch

125 VAC-3A max

G/N

L2

G/NG/N

G

L2 High Leg

G

L3 L1 L2

B B B

Page 22: N Surge Protection

EP.MERSEN.COMN22

SURGE PROTECTIVE DEVICE

DIN-RAIL MODULAR SPD FOR ANSI/UL 1449 TYPE 1 AND 2 APPL ICATIONS

SURGE-TRAP® MODULAR

Surge-Trap® Modular Surge Protective Device (SPD) is a no-fuse, fail-

safe surge suppressor featuring Mersen’s patented TPMOV® technology

inside . UL 1449 4th Edition approved, it is DIN-rail mountable featuring

a fail-safe self-protected design, visual indicator, and a small footprint .

A remote indicator option provides status to critical control circuitry .

The Surge-Trap Modular SPD has a high short circuit rating and a

thermally protected MOV, which eliminates the need for additional

overcurrent protection devices .

F E AT U R E S A N D B E N E F I T S :

• Easy installation or retrofit

• DIN-rail mountable

• Fail-safe, self-protected design

• Remote indicator (optional)

• Visual indicator

• IP20 finger-safe design

• Small footprint

• No additional overcurrent

protection devices required

• 2-year warranty

R AT I N G S :

• Volts (Un): 120-690VAC

• Nominal Discharge Current Rating (In): 20kA

• Surge Capacity (per phase and per mode): 50kA

• Short-Circuit Current Rating (SCCR): 200kA

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 Component Assembly

SPD, File E210793

• ANSI/IEEE C62 .41 .1, C62 .41 .2,

C62 .45

• RoHS Compliant

Page 23: N Surge Protection

EP.MERSEN.COM N23

SURGE PROTECTIONSURGE-TRAP® MODULAR

GENERAL PRODUCT SPECIFICATIONS

1-POLE, SINGLE-PHASE, 2-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L

ST1201PG(M) 120 180 180 - - 500 500 - - 20ST2301PG(M) 240 270 270 - - 800 800 - - 20ST2771PG(M) 277 320 320 - - 900 900 - - 20

2-POLE, SPLIT-PHASE, 3-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L

ST208SPG(M) 120/208 180 180 - 360 500 500 - 900 20ST240SPG(M) 120/240 180 180 - 360 500 500 - 900 20ST480SPG(M) 240/480 270 270 - 540 800 800 - 1500 20

3-POLE, 3-PHASE DELTA, 3-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L

ST2403PD(M) 240 - - - 270 - - - 1000 20ST4803PD(M) 480 - - - 550 - - - 3000 20

3-POLE, 3-PHASE DELTA, 4-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L

ST2403PDG(M) 240 270 270 - 540 800 800 - 1500 20ST4803PDG(M) 480 550 550 - 1100 1500 1500 - 3000 20

3-POLE, 3-PHASE WYE, 4-WIRECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L

ST2083PYG(M) 120/208 180 180 - 360 500 500 - 900 20ST4803PYG(M) 277/480 320 320 - 640 900 900 - 1800 20ST6003PYG(M) 347/600 420 420 - 840 1200 1200 - 2000 20ST6903PYG(M) 400/690 510 510 - 1020 1500 1500 - 3000 20

4-POLE, 3-PHASE WYE, 5-WIRE, INCLUDING N-G MODECATALOG NUMBER

NOMINAL VOLTAGE (VAC)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, VAC) VOLTAGE PROTECTION RATING (VPR, VAC) In (kA)

L-N L-G N-G L-L L-N L-G N-G L-L

ST2083PY(M) 120/208 180 360 180 360 500 900 500 900 20ST4803PY(M) 277/480 320 470 150 640 1000 1500 500 1800 20ST6003PY(M) 347/600 420 690 270 840 1500 2500 800 2500 20ST6903PY(M) 400/690 1020 510 510 1020 3000 1500 1500 3000 20FOR REMOTE INDICTATION, ADD “M” TO THE END OF THE PART NUMBER. EXAMPLE, ST4803PYM. OMIT “M” TO ORDER WITHOUT REMOTE INDICATION. EXAMPLE, ST4803PY.

Mounting: 35mm DIN-RailWire Range: 6-14AWG Solid / Stranded CUTerminal Torque: 14.75 lbs-inDegree of Protection: IP 20Flammability: UL94 V0

Operating & Storage Temperature: -40ºC to + 85ºCVisual End of Life Indicator: Visual TabRemote End of Life Indicator: NO/NC Dry ContactFrequency: 50-60 HzResponse Time: <25 ns

Page 24: N Surge Protection

EP.MERSEN.COMN24

SURGE PROTECTION SURGE-TRAP® MODULAR

DIMENSIONS - STP SERIESPOLES A

IN MM

1 Pole 0.71 18.03

2 Pole 1.42 36.06

3 Pole 2.13 54.1

4 Pole 2.84 72.13

DIMENSIONS - ST SERIES

POLES A

IN MM

1 Pole 0.7 17.8

2 Pole 1.39 35.5

3 Pole 2.1 53.3

4 Pole 2.8 71

WIRING DIAGRAMS

1-POLE, SINGLE-PHASE, 2-WIRE

2-POLE, SPLIT-PHASE, 3-WIRE

3-POLE, 3-PHASE DELTA, 3-WIRE

3-POLE, 3-PHASE DELTA, 3-PHASE WYE, 4-WIRE

4-POLE, 3-PHASE WYE,5-WIRE

4-POLE, 3-PHASE DELTA HIGH-LEG, 5-WIRE

SINGLE PHASE 2 WIRE + GROUND

SPLIT PHASE3 WIRE + GROUND

3 PHASE DELTA3 WIRE + GROUND

3 PHASE WYE4 WIRE + GROUND

REMOTE STATUS INDICATOR

Signal Wire Range #16 to #30 AWG

Terminal Torque 2.2 lb-in

Cont. between Comm + NO Product Offline, Not Protected

Cont. between Comm + NC Product Online, Protected

ST AND STP SERIES: FOR REMOTE INDICATION, ADD “M” TO THE END OF THE CATALOG NUMBER. FOR EXAMPLE, ST4803PYGM.

NO 1

Common 2

NC

Subminiature Switch

125 VAC-3A max

G/N

L2

G/NG/N

G

L2 High Leg

G

L3 L1 L2

B B B

Page 25: N Surge Protection

EP.MERSEN.COM N25

SURGE PROTECTIVE DEVICE

DIN-RAIL PLUGGABLE SPD FOR PHOTOVOLTAIC APPL ICATIONS

SURGE-TRAP® STPT2-PV SERIES FOR PHOTOVOLTAIC

STPT2 40 PV is the series of devices

that provide advanced overvoltage

protection to photovoltaic systems by

utilizing Mersen’s optimized dynamic

thermal disconnection system, which

does not require additional overcurrent

protection (back-up fuse) due to its

high short-circuit withstand rating .

These surge protective devices are

suitable for all PV applications: large-

scale, rooftop, and self-consumption

(off-grid) DC installations .

REFERENCE NUMBER

CATALOG NUMBER

UCPV [VDC]

Up@In (8/20) [kV]

In (8/20) [kA]

SCCR [kA]

CARTRIDGE ID (L)

83020138 STPT2-40K600V-YPV 660 ≤2.6 20 100 C40

83020139 STPT2-40K600V-YPVM 660 ≤2.6 20 100 C40

83020140 STPT2-40K1000V-YPV 1060 ≤4 20 50 C41

83020141 STPT2-40K1000V-YPVM 1060 ≤4 20 50 C41

83020158 STPT2-40K1500V-YPV 1500 ≤5 10 65 C42

83020159 STPT2-40K1500V-YPVM 1500 ≤5 10 65 C42

DIMENSIONS ELECTRICAL DIAGRAM MICROSWITCH DIAGRAM

R AT I N G S :

• Volts (Ucpv): 600-1500VDC

• Nominal Discharge Current Rating (In): 10-20kA

• Surge Capacity (per phase and per mode): 40kA

• Short-Circuit Current Rating (SCCR): 50-100kA

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 2 Component Assembly,

File E468946

• EN 50539-11

• UTE C 61740-51

REPLACEMENT CARTRIDGESNETWORK UCPV

[VDC]

Imax (8/20) [kA]

In(8/20)

@UP [kA]

Up@In (8/20)[kV]

CARTRIDGE ID.REF. NO. CATALOG NO.

83020005 SP2-40K600V-PV PV 330 40 20 ≤1.3 C40

83020006 SP2-40K1000V-PV PV 530 40 20 ≤2 C41

83020010 SP2-40K1500V-PV PV 750 40 10 ≤2,5 C42

Page 26: N Surge Protection

EP.MERSEN.COMN26

EP.MERSEN.COM

SURGE PROTECTIVE DEVICE

DIN-RAIL MODULAR SPD FOR IEC TYPE 2 + 3 APPL ICATIONS

SURGE-TRAP® STMT23 SL IM SERIES

STMT23 20 S is the series of combined Type

2+3/Class II+III devices for discharging voltage

surges while providing a very fine voltage

protection level, in accordance with IEC/EN

61643-11 .

Suitable as the final stage of protection in

panels with Type 2 protection devices installed

upstream . These SPDs should be installed

as close as possible to the equipment being

protected . Ideal for limited spaces . Wide range

of voltage ratings .

REF. NUMBER

CATALOG NUMBER WITHOUT/WITH REMOTE MONIT.

Un [VAC]

UC [V]

Up@In (8/20)[kV]

Imax (8/20) [kA]

I (8/20) [kA]

83230500 83230501

STMT23-6K20V-SP-SSTMT23-6K20V-SP-SM 12 20 ≤0.22 (L1-L2) 0.7 (L1/L2-PE) 6 3

83230504 83230505

STMT23-6K30V-SP-SSTMT23-6K30V-SP-SM 24 30 ≤0.22 (L1-L2) 0.7 (L1/L2-PE) 6 3

83230506 83230507

STMT23-6K60V-SP-SSTMT23-6K60V-SP-SM 48 60 ≤0.33 (L1-L2) 0.7 (L1/L2-PE) 6 3

83230508 83230509

STMT23-6K75V-SP-SSTMT23-6K75V-SP-SM 60 75 ≤0.5 (L1-L2) 0.9 (L1/L2-PE) 6 3

83230502 83230503

STMT23-6K150V-SP-S STMT23-6K150V-SP-SM 120 150 ≤0.7 (L1-L2) 0.9 (L1/L2-PE) 6 3

83230510 83230511

STMT23-20K275V-SP-SSTMT23-20K275V-SP-SM 230 275 ≤1.4 (L1-L2) 1.4 (L1/L2-PE) 20 10

DIMENSIONS ELECTRICAL DIAGRAM MICROSWITCH DIAGRAM

R AT I N G S :

• Volts (Un): 12-230VAC

• Nominal Discharge Current Rating (In): 3-10kA

• Surge Capacity (per phase and per mode): 6-20kA

• Short-Circuit Current Rating (SCCR): 10kA

A P P R OVA L S :

• IEC/EN 61643-11

Page 27: N Surge Protection

EP.MERSEN.COM N27

SURGE PROTECTIVE DEVICE

DIN-RAIL MODULAR SPD FOR IEC TYPE 2 + 3 APPL ICATIONS

SURGE-TRAP® STET23 SERIES

REFERENCE NUMBER

CATALOGNUMBER

Un [VAC]

Uc [V]

Up@In [kV]

In (8/20) [kA] IL [A] REMOTE

(M)

83230401 STET23-20K150V-SPM 120 150 ≤0.8 10 20 √

83230403 STET23-20K275V-SPM 230 275 ≤1.2 10 20 √

DIMENSIONS ELECTRICAL DIAGRAM MICROSWITCH DIAGRAM

STET23 20 is the series of combined Type 2+3/Class II+III

devices for discharging voltage surges while providing a very

fine voltage protection level, in accordance with IEC/EN 61643-11 .

Complete with a built-in powerful EMI filter . Suitable as the final

stage of protection in installations with electromagnetic disturbances

which might interrupt, degrade, or limit system performance . Series

connection for applications up to 20A rated current .

R AT I N G S :

• Volts (Un): 120-230VAC

• Nominal Discharge Current Rating (In): 10kA

• Surge Capacity (per phase and per mode): 20kA

• Load Current Rating (IL): 20A

• EMI Filter: Up to 82dB

A P P R OVA L S :

• IEC/EN 61643-11

Page 28: N Surge Protection

EP.MERSEN.COMN28

SURGE PROTECTIVE DEVICE

IN-L INE SPD FOR LED L IGHTING APPL ICATIONS

SURGE-TRAP® STLB SERIES

Mersen’s SPD for LED lighting applications, the STLB series is a

universal solution with enhanced safety delivering peace-of-mind

to users and installers . A single device is suitable for single, split, or

three-phase applications; can be installed in series or parallel with the

luminaire; features leakage current free technology and visual end-of-

life indication . It is also UL Recognized (cURus) and IEC certified .

F E AT U R E S A N D B E N E F I T S :• Universal, certified SPDs which can be safely used in any luminaire

and any installation• Common applications: Roadway Lighting, Parking Lot/Garage

Lighting, indoor/outdoor LED signage, industrial manufacturing facilities, all critical 24/7 applications

• Parallel or series connected device• End-of-life indication via LED or series disconnection• Leakage Current Free• Global Compliance to ANSI/UL/CSA and IEC• Versatile mounting design accomodates vertical or horizontal

mounting• 2-year warranty

R AT I N G S :

• Volts (Un): 100-277VAC

• Nominal Discharge Current Rating (In): 3kA

• Surge Capacity (per phase and per mode): 10kA

• Short-Circuit Current Rating (SCCR): 10kA

• Load Current Rating (IL): 2 .5A

• IEEE C62.41.2 Location Category: C-High 10kV/10kA

A P P R OVA L S :

• ANSI/UL1449 4th Edition,

Type 4 SPD, File E468946

• EN 61643-11 Type 2+3 SPD

• RoHS Compliant

Page 29: N Surge Protection

EP.MERSEN.COM N29

SURGE PROTECTIONSURGE-TRAP® STLB SERIES

GENERAL PRODUCT SPECIFICATIONS

REFERENCE NUMBER

CATALOG NUMBER SYSTEM VOLTAGE AND CONFIGURATION

In MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV, Uc)

MEASURED LIMITING VOLTAGES (MLV)

L-G L-L L-G L-L

83230320 STLBT23-10K320V-C3U-DD 120V Single Phase240V Single Phase240/120V Split Phase208Y/120V 3-Ph WYE480Y/277V 3-Ph WYE240V 3-Ph DELTA

3kA 320 320 1020 1340

Dimensions Wiring Diagram: Series

Wiring Diagram: ParallelElectrical Diagram

Mounting: 5.5mm Diameter Mounting HoleWiring: Screw Terminals (0.7 Nm)Wire Range: 14-18 AWG Solid/Stranded CuConnection: Series or ParallelEnclosure: IP20Flammability: UL94-V0

Operating & Storage Temperature: -40°C to +85°CRelative Humidity Range: 5 to 95% Visual End-of-Life Indicator: GREEN = OK, OUT = REPLACEFrequency: 50-60HzMaximum Back-up Fuse: Mersen AJT25Response Time (L-L, L-G): 25ns, 100ns

Page 30: N Surge Protection

EP.MERSEN.COMN30

SURGE PROTECTIVE DEVICE

COMPONENT SPD FOR OEM DESIGN AND BUILD

TPMOV® TECHNOLOGY

Mersen’s patented TPMOV technology eliminates common failure

modes that occur in the field with standard metal oxide varistors .

Internally the TPMOV is comprised of a voltage clamping device

and a disconnecting apparatus that monitors the status of the metal

oxide disk, making the TPMOV a fail-safe device . In the event of an

overvoltage breakdown, the metal oxide disk is securely disconnected

from the system power by an arc shield . Upon failure, the TPMOV is

also equipped with a visual pin indicator as well as a normally open

micro-switch, providing remote indication if applicable .

F E AT U R E S A N D B E N E F I T S :

R AT I N G S :

• Volts (Un): 150-550VAC

• Nominal Discharge Current Rating (In): 20kA

• Surge Capacity: 50kA, 75kA

• Short-Circuit Current Rating (SCCR): 200kA

A P P R OVA L S :

• ANSI/UL 1449 4th Edition,

Type 1 Component Assembly

SPD, File E210793

• RoHS Compliant

• 50% more surge capacity —same

footprint: The TPMOV7 is rated for

75kA - 8/20μs peak surge current

and is available for MCOV from

150V to 320VAC .

• Consistent footprint with

25–40mm MOVs

• Industry-leading, patented TPMOV

technology available in 50kA

and 75kA surge capacities

• Built-in visual/remote

indication optional

• Wave solderable

• No additional overcurrent

protective device (fuses)

required

Page 31: N Surge Protection

EP.MERSEN.COM N31

SURGE PROTECTIONTPMOV® TECHNOLOGY

CATALOG NUMBER (INCLUDES SUFFIXES*)

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV)

VOLTAGE PROTECTION RATING (VPR)

NOMINAL DISCHARGE CURRENT (kA)

OPERATING TEMPERATURE

TPMOV DIMENSION A (INCHES)

150TPMOV (7) 150VAC 600 20 -40°C to +85°C 0.485

180TPMOV 180VAC 800 20 -40°C to +85°C 0.485

270TPMOV 275VAC 800 20 -40°C to +85°C 0.495

320TPMOV (7) 320VAC 1000 20 -40°C to +85°C 0.51

420TPMOV 420VAC 1500 20 -40°C to +85°C 0.54

510TPMOV 510VAC 1500 20 -40°C to +85°C 0.54

550TPMOV 550VAC 1500 20 -40°C to +85°C 0.545

CATALOG - ORDERING SYSTEM (TPMOV)

150Maximum Continuous

Operating Voltage(MCOV)

150: 150VAC180: 180VAC270: 275VAC320: 320VAC420: 420VAC510: 510VAC550: 550VAC

TPMOVModel Series

TPMOV: Thermally Protected MOV

7Surge Capacity

BLANK: 50kA7: 75kA

SLMechanical Options

* For details regarding HV microswitch please consult factory

Dimensional Drawing of TPMOV Board Layout Dimensions

VOLTAGE A DIMENSION

550 0.545

420/510 0.54

320 0.51

270 0.495

150/180 0.485

Suffix PCB Leads Tact Switch Visual Tabs Pkg Qty

Blank No Yes Yes 10

S Yes Yes No 10

SL Yes Yes No 500

ST Yes Yes Yes 10

SLT Yes Yes Yes 500

HV No Yes-HV Yes 10

S-HV Yes Yes-HV Yes 10

SL-HV Yes Yes-HV Yes 500

.407

1.375

.146

A.627

1.687

2X .325

2X .037

.231.197

2X Ø .039

.844

SWITCH LEADS

CONTACT LEAD

MOV LEAD

SCALE: 2:1TOLERANCES: ± .005

.407

1.375

.146

A.627

1.687

2X .325

2X .037

.231.197

2X Ø .039

.844

SWITCH LEADS

CONTACT LEAD

MOV LEAD

SCALE: 2:1TOLERANCES: ± .005

Page 32: N Surge Protection

EP.MERSEN.COMN32

SURGE PROTECTIVE DEVICE

COMPONENT DEVICE FOR OEM DESIGN AND BUILD

VSP MOV PROTECTOR FUSE

Mersen surge suppression fuses are specially designed to address

the protection of SPD systems . Our surge suppression fuses have

been specially designed to withstand 8/20 μSec surge pulses without

opening, allowing the SPD system to react to the surge . All surge

suppression fuses have a 8/20 μSec surge rating, not a continuous

current rating . Under AC short circuit conditions these surge

suppression fuses are very current limiting .

F E AT U R E S A N D B E N E F I T S :

• VSP fuses rated 600VAC, 200kA I .R .

• Surge ratings of 5-100kA 8/20 μSec capacity

• Various mounting configurations ferrules, blade, bolt-in, pc board

mount

R AT I N G S :

• Volts: 600VAC

• Surge Rating: 5-100kA 8/20

μSec

• Interrupting Rating (IR): 200kA

A P P R OVA L S :

• ANSI/UL 248 Special Purpose

MOV Fuse, File E60314

Page 33: N Surge Protection

EP.MERSEN.COM N33

SURGE PROTECTIONVSP MOV PROTECTOR FUSE

PRODUCT PERFORMANCE DATA VSP (5-20)-2,R,H,S

CATALOG NO. (CONNECTION SUFFIX)

VOLTAGE RATING (AC)

8X20 µSEC SURGE RATING

MELTING I2T (A2S)

CLEARING I2T (A2S)

IPEAK@ 100KA 60 HZ (A)

VSP5-2,-R,-H,-S 600V 5,000 341 936 3,652

VSP10-2,-R,-H,-S 600V 10,000 1,541 3,744 5,794

VSP15-2,-R,-H,-S 600V 15,000 3,072 8,424 7,591

VSP20-2,-R,-H,-S 600V 20,000 4,992 14,400 9,194

VSP30, -2 600V 30,000 12,507 33,696 12,044

VSP40, -2 600V 40,000 19,543 59,904 14,588 VSP (30-100)-2

VSP50, -2 600V 50,000 32,020 93,600 16,925

VSP60, -2 600V 60,000 42,808 134,784 19,110

VSP70, -2 600V 70,000 61,152 183,456 21,176

VSP80, -2 600V 80,000 79,872 239,616 23,146

VSP90, -2 600V 90,000 99,000 303,264 25,034

VSP100, -2 480V 100,000 121,500 374,400 26,854

VSP100-XL 600V 100,000 121,500 374,400 26,854

RECOMMENDED FUSE BLOCKS FOR VSP FUSES VSP30-100

VSP(5-20)-2

NUMBER OF POLES SCREW WITH DOUBLE QUICK CONNECTS

PRESSURE PLATE WITH DOUBLE QUICK CONNECTS

COPPER BOX CONNECTOR

ADDER 30310 30320 30350

1 30311 30321 30351

2 30312 30322 30352

3 30313 30323 30353 VSP100-XL

VSP(30-100)-2

NUMBER OF POLES CATALOG NUMBER

ADDER 60305J 60315J 60325J

1 60306J 60316J 60326J

2 60307J 60317J 60327J

3 60308J 60318J 60328J

MOUNTING OPTIONS

DOUBLE HOLE MOUNT (ROUND HOLES)

-H

PC BOARD MOUNTING

-R

SURFACE SCREW MOUNT

-S

Page 34: N Surge Protection

EP.MERSEN.COMN34

SURGE PROTECTIVE DEVICE

COMPONENT DEVICE FOR OEM DESIGN AND BUILD

SURGE-RATED DISCONNECT SWITCH

The Surge Switch is an extremely compact, high performance,

manually operated, non-fused switch . It is specifically designed to

withstand the high surge current of 200kA with an 8x20 µs waveform

seen in today’s transient voltage surge protection device (SPD)

applications . Mersen’s Surge Switch utilizes a unique contact design

that actually clamp contacts tighter during a surge .

F E AT U R E S A N D B E N E F I T S :

• Only surge rated switch available today

• Compact footprint

• Extremely reliable

• Defeatable pistol handles automatically relatch when panel door is

closed, no tool necessary to reset latch

• Direct mount handle option

R AT I N G S :

• Volts: 600V AC

• Amps: 600A

• Surge Rating: 200kA 8x20 µs

wave form

A P P R OVA L S :

• UL Listed Guide NRNT, File

E224922

Page 35: N Surge Protection

EP.MERSEN.COM N35

SURGE PROTECTIONSURGE-RATED DISCONNECT SWITCH

CATALOG NUMBER DESCRIPTION

SS200 3-pole, surge switch, 200kA 8x20 µs

SS200-4 4-pole, surge switch, 200kA 8x20 µs

HADSS200 Direct mount black handle

HGPB External black handle, NEMA 1,3R, 12 (IEC IP 54), defeatable

HGPR External red handle, NEMA 1,3R,12 (IEC IP 54), defeatable

HGPB4 External black handle, NEMA 1,3R,124,4X (IEC IP 65), defeatable

HGPR4 External red handle, NEMA 1,3R,12,4,4X (IEC IP 65), defeatable

SG200-10 Shaft, 7.9 in (200 mm)

SG320-10 Shaft, 12.6 in (320 mm)

SG400-10 Shaft, 15.7 in (400 mm)

TS200SS Terminal Shield, 3-pole

TS2004SS Terminal Shield, 4-pole

DIMENSIONS (dual dimensions: in/mm) SS200 DIMENSIONS (dual dimensions: in/mm) SS200-4

DIMENSIONS: HADSS200 DIMENSIONS: PISTOL HANDLE TYPE G

HGPB

HGPR

HGPB4

HGPR4

DIMENSIONS: PISTOL HANDLE TYPE G

SS200/SS200-4

SHAFT LENGTH H MINIMUM DIMENSION H MAXIMUM DIMENSION

IN MM IN MM IN MM

7.9 200 4.88 124 9.29 236

12.6 320 4.88 124 14.01 356

15.7 400 4.88 124 17.16 436

O - OFF

I - ON

90°

3.15 80

652.56

0.6717

4.73120

2.8773

2.78

70.5

2.7570

50

90°

o2"502"

ø 3111 4"

4 ø 4.51 8"

-ON

-OFF

DOOR DRILLING