towerMAX CAT6-75Protects one 8-wire Category 6 line using 110 connectors.
• Pins 1–8 protected
• Clamping level 75V
• Suppression: All pins to ground
• Lifetime Product and Connected Equipment Warranty
Part No. CAT6-75
towerMAX CAT6-LAN*Protects one 8-wire Category 6 lineusing 110 connectors.
• Pins 1–8 protected
• Clamping level 16V
• Suppression: All pins to ground
• Lifetime Product and Connected Equipment Warranty
Part No. CAT6-LAN
6
NEW!
6
NEW!
towerMAX CAT6-235Protects one 8-wire Category 6 line using 110 connectors.
• Pins 1–8 protected
• Clamping level 235V
• Suppression: All pins to ground
• Lifetime Product and Connected Equipment Warranty
Part No. CAT6-235
6
NEW!
Cat 6 / Cat 6 for Power Over Ethernet
towerMAX T1/ISDNProtects 1 (T1, ISDN) line per port.T1—2 pairs (pins 1 & 2 / 4 & 5)ISDN—BRI/PRI compatible.
• Clamping level 70V
• Capacitance approximately 50 pF
• Suppression mode: metallic & longitudinal
• Lifetime Product and Connected Equipment Warranty
Part No. MLLT1
towerMAX CAT5-LAN-RJ45*Protects one 8-wire Category 5line using RJ-45 connectors.
• Pins 1–8 protected
• Clamping level 16V
• Suppression: All pins to ground
• Lifetime Product and Connected Equipment Warranty
Part No. CAT5-LAN-RJ45
towerMAX CAT5e-LANProtects one 8-wire Category 5e lineusing 110 connectors.
• Pins 1–8 protected
• Clamping level 16V
• Suppression: All pins to ground
• Lifetime Product and Connected Equipment Warranty
Part No. CAT5-LAN
5e 5
Cat 5e / Cat 5 / T1 / ISDN / Cat 5e for Power Over Ethernet
CAT5-LAN
CAT5-LAN-110/RJ45
CAT5-LAN-RJ45
CAT5-POE
CAT5-75
CAT5-75-110/RJ45
CAT5-75-RJ45
CAT5-235
CAT5-235-110/RJ45
CAT5-235-RJ45
ITW Linx Part Number
16 VDC
16 VDC
16 VDC
16 V Data / 62 V Power
75 VDC
75 VDC
75 VDC
235 VDC
235 VDC
235 VDC
Clamping VoltageConnection Type
110 In / Out
110 In / RJ-45 Out
RJ-45 In / Out
Any of the above
110 In / Out
110 In / RJ-45 Out
RJ-45 In / Out
110 In / Out
110 In / RJ-45 Out
RJ-45 In / Out
Category 5e Primary Protector—4-pair, UL Listed
Category 5e Primary Protector—4-pair, UL Listed
Category 5 Primary Protector—4-pair, UL Listed
Category 5e Primary Protector—4-pair, UL Listed
Category 5e Primary Protector—4-pair, UL Listed
Category 5e Primary Protector—4-pair, UL Listed
Category 5 Primary Protector—4-pair, UL Listed
Category 5e Primary Protector—4-pair, UL Listed
Category 5e Primary Protector—4-pair, UL Listed
Category 5 Primary Protector—4-pair, UL Listed
Description
VOIC
E/IS
DN
APP
LICA
TIO
NS
L
AN
APP
LICA
TIO
NS
Part Number Matrix
*Also available for Power Over Ethernet—CAT6-POE— (16V clamping on Data pairs and 62V clamping on Power pairs
*RJ45 In/Out meets Category 5 performance
• SurgeGate™ Circuitry—automatic "power monitoring" for over-voltage protection• Protect or Disconnect™ Circuitry—completely disconnects during a catastrophic surge• Expandable Protection—allows unlimited module configurations• Diagnostic indicator lights• 8 ft. AC power cord• For up-to-date warranty information visit our web site: itwlinx.com
COMMON FEATURES FOR towerMAX 4 and towerMAX 8 FAMILIES
towerMAX 8 KSU
• 8 protected, transformerspaced, AC power outlets
• SurgeGate Plus™ Circuitry
• Lifetime Product andConnected EquipmentWarranty
Part No. M8KSU-60
towerMAX® 8 COM/DATA
• 8 protected, transformer spaced,AC power outlets
• SurgeGate Plus™ Circuitry
• Protects 4 Phone lines,1 T1/ISDN & 1 LAN line
• Auto-resetting Phone Circuitry
• SignalPerfect™ Circuitry
• Ethernet Protection—for 10/100 BASE-T LANs
• Lifetime Product and Connected Equipment Warranty
Part No. M8COM-60
towerMAX 8 Base Units
towerMAX 4 Base Units
towerMAX 4 KSU
• 4 protected, transformerspaced, AC power outlets
• SurgeGate Plus™ Circuitry
• AC Master On/Off Switch
• Lifetime Product andConnected EquipmentWarranty
Part No. M4KSU
towerMAX 4 LAN
• Protection for one LAN 10/100BASE-T line RJ-45
• SurgeGate Plus™ Circuitry
• 4 protected, transformer spaced, AC power outlets
• SignalPerfect™ Circuitry
• AC Master On/Off Switch
• Lifetime Product and Connected Equipment Warranty
Part No. M4L
towerMAX 4 TEL
• Protection for one telephone lineRJ-11/45
• SurgeGate Plus™ Circuitry
• 4 protected, transformer spaced,AC power outlets
• AC Master On/Off Switch
• Lifetime Product and ConnectedEquipment Warranty
Part No. M4T
towerMAX CO/4 Protects up to four lines using two RJ-14 connectors (2 in, 2 out)
• Pins 3 & 6 and 4 & 5 protected
• Lifetime Product and Connected Equipment Warranty
Part No. MC04
towerMAX CO/4×4Protects four lines using RJ-11/45 connectors
• 1 CO pair per jack, Pins 4 & 5 protected
• Lifetime Product and Connected Equipment Warranty
Part No. MC04X4-60
• Clamping level 260V • Solid-state Circuitry • Prevents “sneak current” damage • Capacitance approximately 30 pF• Suppression modes: metallic & longitudinal • For up-to-date warranty information visit our web site: itwlinx.com
towerMAX CO/4-110Protects up to four lines using one 110 punchdown block on the inputand one 110 punchdown block or four RJ-11 or two RJ-14 jacks on the output.
• Lifetime Product and Connected Equipment Warranty
Part No. MC04110
towerMAX CO/25Protects twenty-five CO lines using 50 Pin, RJ-21X (Amphenol)connectors.
• All pins protected
• Lifetime Product and Connected Equipment Warranty
Part No. MC025-60
towerMAX DS/2Protects one 8-wire line (e.g. AVAYA®
ATL) using RJ-45 connectors or two 4-wire lines (e.g. Lucent MLX) using RJ-11/45 connectors.
• Clamping levels:Path 1: Pins 1–8, 70V T/R; 110V T/G, R/G
• Path 2: Pins 3–6, 70V T/R; 110V T/G, R/G
• Lifetime Product and Connected Equipment Warranty
Part No. MDS2-60
towerMAX DS/25Protects up to twenty-five 2-wiredigital station lines or up to twelve4-wire digital station lines usingRJ-21X connectors.
• Clamping level 110V
• Suppression modes: metallic & longitudinal
• Lifetime Product and Connected Equipment Warranty
Part No. MDS25
towerMAX DS/COProtects two 4-wire digital/analoglines (e.g. AVAYA Partner®) or two 2-wire tip/ring analog lines using RJ-11/45 connectors.
• Clamping levels:Pins 3 & 6, 70V T/R; 110V T/G, R/G
• Pins 4 & 5, 260V T/R, T/G, R/G
• Lifetime Product and Connected Equipment Warranty
Part No. MDSCO-60
towerMAX CO/8-110Protects up to eight lines usingtwo 110 punchdown blocks on theinput and two 110 punchdownblocks on the output.
• Lifetime Product and Connected Equipment Warranty
Part No. MC08110
COMMON FEATURES FOR towerMAX CO MODELS
Analog Lines
Analog Lines / 110 Punchdown
Digital Lines
towerMAX 4 KSU
towerMAX 8 KSU
towerMAX 8 COM/DATA
towerMAX CO/4x4
towerMAX CO/25
towerMAX CO/4-110
towerMAX CO/8-110
towerMAX DS/CO
towerMAX DS/2
towerMAX SCL/8
Product Name
towerMAX SCL/8Protects eight wires and providesfour common ground connections.
• Screw terminals, 1–8 protected
• Clamping level 47V
• Suppression mode: All terminals to ground
• Lifetime Product and Connected Equipment Warranty
Part No. MSCL8-60
towerMAX RS/2Protects two 8-wire RS-232 linesusing RJ-45 connectors.
• Pins 1–8 protected
• Clamping level 30V
• Suppression mode: All pins to ground
• Lifetime Product and Connected Equipment Warranty
Part No. MRS2
towerMAX RS/DBProtects one 25-wire RS-232 line using DB25 connectors.
• All pins protected
• Clamping level 30V
• Suppression mode: • All pins to ground
• Lifetime Product and Connected Equipment Warranty
Part No. MRSDB
Paging Lines
N/A
407676691
407939461
407228923
408183044
N/A
N/A
407568146
407568161
407676717
SAP Material Code COMCODE
700209794
105125
407939461
105122
105124
700209802
700209810
105127
105126
105123
8310-030
8310-012
8310-028
8310-004
8310-011
8310-031
8310-032
8310-014
8310-013
8310-010
PEC No.AVAYA Part No.
145J
145D
147D
146C
146H
146J
146K
146D
146E
146G
M4KSU
M8KSU-60
M8COM-60
MCO4X4-60
MCO25-60
MCO4110
MCO8110
MDSCO-60
MDS2-60
MSCL8-60
ITW Linx Part No.
MO
DU
LES
B
ASE
UN
ITS
AVAYA and ITW Linx Product Part Numbers
TO CENTRAL OFFICE
UPS
KSUTELECOMPRIMARYPROTECTORANDCONNECTION BLOCK
PRIMARYPROTECTOR
REMOTE BUILDING
ACSIGNAL
GROUND
towerMAX Base Units Common Features Expandable Phone System Protection
Typical installationusing towerMAX4 KSU. Additionalmodules caneasily be added toaccommodate anyconfiguration.
• TransformerSpacing on Outlets
• Power On/Protection OK
• Unsafe Voltage
AC Outlets •
Ground OK •
• PowerSwitch
Line Fault •
LED INDICATORS:
Module and Wall Mounting Bracket •
• CommonGroundConnectionfor Modules
towerMAX 4 KSUshown on left. Similar features canbe found on othertowerMAX AC units,see their productdescriptions.