Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
A-23
9/12/2018
9/12/2018
Requested By: AVariance
Type: WS
Request Prepared By *: 023
0.10 To: 0.10PA-WEWV-H600-01
In or w/in 50' of a waterbody:
N/A
N/AAdditional Stream
footage impacted: 0.00 0.00
Net acreage affected: + 0.87
Tree Clearing Required: Yes
Variance Level:
Variance From:
Attachments? Photos?
List Attachments:
Variance Justification:Resources have been avoided to the extent practicable. Per approved Project plans, BMPs will be installed to minimize impacts to any Environmentally Sensitive Areas within/abutting the area.
Additional Wetland impacts:
In or w/in 50' of a wetland:
MYSO (+ 0.87 ac KUSH)
Milepost:
This variance adds MVP-ATWS-SM-017 for slip remediation. No streams, wetland or cultural resources were found during delineations. This variance has a net increase of 0.87 acres of LOD from the original permit. There is a net increase in tree clearing of 0.87 acres. The modification of the tree clearing results in a net increase of 0.87 acres MYSO - Known Use Summer Habitat (KUSH). On January 29, 2018 the USFWS concurred with MVP's proposed process for reviewing variances that require tree clearing. Attachment 2 includes a table that shows MVP's acreage "banks" will remain net positive following approval of this variance request.
Wetland or Waterbody ID:
WV-WE-001
Variance Request
No.:
Date Received by FERC:Date Submitted by Chief Inspector to LEI:
MVP Variance Request Form
Date Approval Requested by Contractor:
Attachment 1-Alignment Sheet; Attachment 2- Rare, Threatened, and Endangered Species Report; Attachment 3- Waterbodies and Wetlands
Report; Attachment 4- Cultural and Historic Resources Report (CUI/PRIV -- DO NOT RELEASE) ; Attachment 5- Landowner Exhibits (CUI/PRIV -- DO NOT RELEASE) ; Attachment 6- Pipeline Variance
Request Map
Variance Sequence
Number:Megan Neylon
To: 5+94
FERC Approval Reference No.:
Station: 1+40
Alignment Sheet Number:
Current Land Use/ Vegetative Cover:
Brent Ladd
Tract No.:
Nearby Features (Water body, T&E Habitat, Wetland, Noxious Weed
Area, Residence (distance), Cultural Resource Site (distance) etc.):
Acreage of tree
clearing:
Spread:
Location (Use either Station or Milepost)
Detailed Description of Variance:
Other Agency
Jurisdiction:Deciduous Forest
+ 0.87
* The FERC compliance monitor should be alerted and given a copy of the draft variance for review prior to submittal.
EPPM DrawingSpecification Mitigation Measure
Yes No
Permit
Yes No
Level 1 Level 2
Yes No No
Level 3
Other: Describe:
No
Yes No
Yes NoNoxious Weed Area Raptor Nest Residence (Distance)
Cultural Resource SiteT/E Species Habitat
Other (Specify):
Water Well
Plan Procedures
Line List
Additional Surveys
Completed
Landowner:
Land Agent ContactLandowner Approval
Obtained
Date
10/10/201810/10/2018
10/10/201810/10/2018
Third Party Compliance Manager or monitor
Environmental Supervisor
Brent LaddConstruction Manager
Janna ArnoldROW Land Agent *
Lead Environmental Inspector
For MVP Use Only
Sign Off: Name Signature
Surveyed Corridor Description
The locations for this variance request were evaluated for cultural resources, waterbodies and wetlands, threatened and endangered species, and habitat. See the attached cover page list of reports.
Waterbodies/WetlandsProof of Previous Biological and Cultural Survey Clearance
Additional Surveys Required
Cultural Survey
*signature denotes confirmed landowner approval
Brent LaddTravis Huskins Travis Huskins
T & E Survey
Janna Arnold
Megan Neylon Megan Neylon
See attachments 2 and 3 that describe rare, threatened, and endangered species surveys and stream and wetland delineations. USFWS Biological Opinion was issued on 10/31/2017. The cultural resources survey was reported in: Mountain Valley Pipeline Project, Slip Mitigation Workspaces MVP-ATWS-SM-016 and MVP-ATWS-017 Request for Concurrence on Disturbance and No Further Survey Recommendation (Freedman August 2018). Filed with FERC 9/7/2018. Clearance received from WVDCH 9/5/2018. The Concurrence Letter is
provided in Attachment 4.
REDACTED
JANNA ARNOLD
Yes NoYes NoYes NoYes NoYes No
Yes NoYes NoYes NoYes NoNoNo
Yes
Yes
No
No
Yes NoYes NoYes NoYes NoYes NoYes No
Yes No Yes No
Variance Approved:Signature:
Date:Stipulations:
Spread No.: A A-23
Name: Title: Conditions:
Name:
Conditions:
Name:
Conditions:
Variance Denied:For FERC Compliance Monitor and Compliance Manager Use Only
Variance Request No.:
Beyond Authority:
Title: Organization:
Organization:
Organization: VARIANCE CONDITIONS
Title:
Mountain Valley Pipeline, LLC Mountain Valley Pipeline Project
Docket No. CP16-10-000
Alignment Sheets Attachment 1
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
X
X
X
X
X
X
P
/L
P
/
L
P
/
L
P
/
L
P
/
L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P/L
P/L
P
/
L
P
/
L
P
/
L
P
/L
P
/L
P
/
L
P
/
L
P
/L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P/L
P/L
P/L
P/L
P/L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/L
P
/L
P
/L
P
/L
P
/
L
P/L
P
/L
R/W
R/W
R/W
R
/W
R
/
W
R
/
W
R
/W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/W
R
/
W
R
/
W
R/W
R/W
R/W
R
/W
R
/
W
R
/
W
R
/W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R/W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R
/
W
R/W
R
/
W
R
/
W
W
W
1
0
+
0
0
2
0
+
0
0
3
0
+
0
0
40+
00
5
0
+
0
0
6
0
+
0
0
WW
WW
WW
TANK
T
S
1
T
S
1T
S
4A
T
S
4B
T
S
4B
T
S
5
T
S
1
T
S
4A
T
S
4A
T
S
9
T
S
4A
GM
GM
GM
GM
GM
GM
GM
GM
GM
SCO
PWR
PWR
PWR
PWR
PWR
PWRPWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
P
W
R
P
W
R
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
GP
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
X
X
X
W
W
W
W
W
W
W
MP
0.5
MP
1.0
MVP-ATWS-003A
35,312 SQ FT
MVP-ATWS-002
17,943 SQ FT
MVP-ATWS-735A
1,733 SQ FT
MVP-ATWS-410
6,287 SQ FT
S-A3a
W-A2a
S-A1a
S-A2a
W-A1a
W-A3a
S-J63
P
P
P
R
/W
R
/
W
R
/
W
R
/
W
R
/
W
P
P
x
x
x
x
x
x
x
S-TT1
W-TT1
W-TT2
R
/
W
R
/W
R
/W
W
W
P
P
P
P
P
P
P
R
/W
R/W
R
/
W
R
/
W
R
/W
R/W
R/W
R
/W
R
/W
R
/
W
R
/
W
R
/
W
R
/
W
R
/W
R/W
R
/W
R
/W
P
P
P
P
P
P
P
P
P
P
X
X
X
X
P
P
P
200
4099
58
+6
6M
AT
CH
L
IN
E
00+
00
58+
66
58+
66
10+
67
18+
94
19+
41
19+
47
19+
53
19+
73
24+
54
16+
63
WV-WE-001
WV-WE-001.02
596 LF
597 SLOPE
WV-WE-001
231 LF
232 SLOPE
WV-WE-001
47 LF
47 SLOPE
WV-WE-002
481 LF
492 SLOPE
6 LF
6 SLOPE
6 LF
7 SLOPE
WV-WE-001
WV-WE-003
20 LF
20 SLOPE
WV-WE-001
WV-WE-002
WV-WE-0006
WV-WE-005
135 LF
136 SLOPE
WV-WE-005
WV-WE-005.01
95 LF
98 SLOPE
CO
UN
TY
R
OU
TE
1
5
WV-WE-002
881 LF
973 SLOPE
WV-WE-0006
579 LF
589 SLOPE
WV-WE-005
1641 LF
1725 SLOPE
WV-WE-005
51 LF
54 SLOPE
33+
35
39+
44
33+
65
40+
79
30
L
F - 3
0 S
LO
PE
57+
20
58+
15
WV-WE-001
WV-WE-003
WV-WE-002
33+
18
34+
69
1
2840'
1
4
160'
1
1259'
WETZEL COUNTY, WEST VIRGINIA
58
+6
6 M
AT
CH
L
IN
E - S
EE
S
HE
ET
P
A-W
EW
V-H
60
0-0
2
EQT H302 PIPELINE
WV-WE-001
EQT H306 PIPELINE
HOUSE
WV-WE-002
WV-WE-001.02
WV-WE-001.01
WV-WE-003
WV-WE-0006
WV-WE-0006
WV-WE-005
WV-WE-005.01
H-600 SITE 1
PROPOSED MOBLEY
INTERCONNECT SITE
MVP-WE-003
M
V
P
-
W
E
-
0
0
1
M
V
P
-
W
E
-
0
0
1
M
V
P
-
W
E
-
0
0
1
WV-WE-001.02 WV-WE-001.02WV-WE-001.02 WV-WE-001.02WV-WE-001.02
MVP-WE-004
WV-WE-001
WV-WE-001.01
PROPOSED MOBLEY LAUNCHER
& MAIN LINE VALVE MVP-MLV-01
11+
65
MVP-WE-000
CO RTE 80
CAUTION! PIPELINE CROSSING
SEE CROSSING PLAN
FPCX-H600-002
CAUTION! PIPELINE CROSSING
SEE CROSSING PLAN
FPCX-H600-003 & 04
ALLIANCE PET.
CORP. 2"GAS LINE
TO BE RELOCATED
CAUTION!
PIPELINE
CROSSING
SEE CONSTRUCTION DETAIL
DWG# RSS-H600-01
RSS-H600-01 RESIDENTIAL SITE SPECIFIC
TY
PE
4A
T
ES
T S
TA
TIO
N - S
IN
GLE
LIN
E F
OR
EIG
N X
IN
G
142"O
.D
. X
0.617"W
.T
., X
-70, F
US
IO
N B
ON
DE
D E
PO
XY
TY
PE
1 T
ES
T S
TA
TIO
N - P
IP
ELIN
E
442"O
.D
. X
0.740"W
.T
., X
-70, F
BE
&
A
RO
1 1.1
25.0'
25.0'
12.5'
62.5'
25.0'
25.0'
125.0'
12.5'
62.5'
BEGIN HYDROTEST SEGMENT 01A
125.0'
CAUTION! PIPELINE
CROSSING
CAUTION! PIPELINE CROSSING
SEE CROSSING PLAN
FPCX-H600-005
PROPOSED 42" H600
MOUNTAIN VALLEY PIPELINE
MVP-MLV-01
00+
00
1016 LF
1115 SLOPE
CAUTION! PIPELINE CROSSING
SEE CROSSING PLAN
FPCX-H600-001
0+
51
WV-WE-001.01
51 LF
52 SLOPE
S-A1a
37 LF
W-A1a
15 LF
W-A2a
84 LF
S-A3a
9 LF
ROAD DRAIN
MVP-WE-000
S-ST10
S-ST-11
S-ST12
S-ST19
S-ST18
S-ST14
S-ST-13
MVP-WE-003
MVP-WE-004
S-A3a
W-A3aW-A2aS-A1a
W-A1a
CAUTION!
PIPELINE
CROSSING
CAUTION! PIPELINE
CROSSING
CO RTE 15/17 -
N FORK ROAD
S-A2a
RIGHT-OF-WAY &
OWNERSHIP DATA
PLAN VIEW
WORK SPACE
EN
VIR
ON
ME
NT
AL
PIP
EL
IN
E A
LIG
NM
EN
T
MO
UN
TA
IN
V
AL
LE
Y P
RO
JE
CT
- H
600 L
IN
E
DRAWN BY: HEI(DRF)
DRAFTING CK:
ENGINEERING CK:
DRAWING NO.:
DATE OF PLOT:
SHEET OF 329
HORZ. SCALE: 1" = 200'
AFE/P.O.NO.:
HEI PROJECT NO.: 14-10-052
PA-WEWV-H600
MA
TE
RIA
L S
UM
MA
RY
RE
VIS
IO
NS
MK
. N
O.
QT
Y.
DE
SC
RIP
TIO
NR
EV
.D
AT
EB
YD
ES
CR
IP
TIO
N
AP
PR
OV
ED
FO
R B
ID
DIN
G
AP
PR
OV
ED
F
OR
CO
NS
TR
UC
TIO
N
RE
V.
BY
DA
TE
DE
SIG
N
0' 100' 200' 400'
PIPE / COATING
CLASS LOCATION / HCA
WETLAND / STREAM
.
.
SLOPE DISTANCE
CONSTRUCTION CK:
ENVIRONMENTAL CK:
RE
V.
BY
DA
TE
AP
PR
OV
ED
FO
R F
ER
C
RE
V.
BY
DA
TE
AE
RIA
L P
HO
TO
GR
AP
HY
D
AT
E: A
PR
IL
2015 &
JA
NU
AR
Y 2016
0R
RR
10
-1
5-1
5
CONSTRUCTION METHOD
3R
RR
09
-0
3-1
6
CONSTRUCTION
EXCLUSION
6JJS
11
-2
7-1
7
HE
I1
0-1
5-1
5R
EV
. 4
.0
.0
IS
SU
ED
T
O F
ER
C
REFERENCE DRAWINGS
DRAWING NO. DESCRIPTION
HORIZONTAL
STATIONING
0
Mo
un
tain
V
alley
ISSUED FOR CONSTRUCTION
PERMANENT EASEMENT
TEMPORARY
WORK SPACE(TWS)
ADD. TEMPORARY
WORK SPACE(ATWS)
EXISTING PIPELINE
PROPOSED PIPELINE
ACCESS ROAD
TEMPORARY WORK SPACE
LEGEND
EXISTING PIPELINE
PROPOSED 42"PIPELINE
WORK SPACE LIMITS
TEMPORARY ACCESS RD
PERMANENT ACCESS RD
PROPERTY LINE
OVERHEAD POWER
P/L
OVERHEAD TELEPHONE
P
DELINEATED STREAM
T
C/L ROAD
C/L RAILROAD
DELINEATED WETLAND
PI SYMBOL
POWER/TELE POLE
GUY ANCHOR
GAS VALVETANK
WELL - GAS/OIL/WATER/
MONITORING
POST - GATE/FENCE
ELEC/GAS/WTR METER
TELPWR
TANK
GW
CATCH BASIN - CULVERT
WW
FENCE LINE
X
ANCILLARY SITE
OW
TREE
PROPOSED TEST STATION
ROAD RIGHT-OF-WAY
R/W
ABOVE GROUND FACILITY
LINE MARKER - VENT PIPE
GP
ADDITIONAL TEMPORARY
WORK SPACE(ATWS)
WMGMEM
T
S
#
LM
PEDESTAL - UTILITY
EP
PED TEP FOP TVP
NON-SURVEYED C/L
500' TICK MARK
MNWWELL
FP
POST
TOWER LEG
TWR
SIGN
MH - SANITARY/WATER
SAMH WMH
MAILBOXMB
PERMANENT EASEMENT
STUDY CORRIDOR
BARRICADE FENCE
COUNTY LINE
LIMITS OF DISTURBANCE
1H
EI
01
-1
1-1
6F
ER
C D
AT
A R
EQ
UE
ST
N
o.1
2H
EI
04
-1
4-1
6F
ER
C D
AT
A R
EQ
UE
ST
N
o.2
3H
EI
09
-0
3-1
6R
EV
. 4
.1
.1
3 IS
SU
ED
F
OR
B
ID
4R
RR
10
-1
4-1
6
220 H
oover B
oulevard, S
uite 2
Holland, M
ichigan 49423-3766
T 616-392-5938
F 616-392-2116
26555 E
vergreen R
d. S
uite. 430
Southfield, M
ichigan 48076
T 248-827-7322 F
248-827-7549
ww
w.h
olla
nd
en
gin
ee
rin
g.co
m
4H
EI
10
-1
4-1
6O
CT
OB
ER
2
01
6 P
RO
PO
SE
D R
OU
TE
- IS
SU
ED
T
O F
ER
C
5H
EI
11
-1
1-1
6R
EM
OV
E E
QU
AT
IO
NS
PROFILE
CONSTRUCTION METHOD KEY
1 - TYPICAL R/W WORKING SIDE RIGHT
1.1 - TYPICAL R/W WORKING SIDE LEFT
2 - TOPSOIL SEGREGATED R/W WORKING
SIDE RIGHT
2.1 - TOPSOIL SEGREGATED R/W WORKING
SIDE LEFT
3 - TYPICAL WETLAND X-ING
4 - ROAD X-ING - BORE
5 - RAILROAD X-ING - BORE
6 - WATERBODY X-ING OPEN CUT - FLUME
7 - PARALLEL TO POWER LINE
8 - RIDGE CONSTRUCTION
10 - HDD ENTRY PLAN
11 - HDD EXIT PLAN
12 - HDD CONSTRUCTION
13 - PARALLEL TO POWER LINE
14 - PARALLEL TO POWER LINE
15 - WATERBODY X-ING OPEN CUT -
DRY/DAM & PUMP
33 - SIDE HILL CONSTRUCTION
34 - 2-TONE SIDE HILL CONSTRUCTION
53 - REDUCED CONSTRUCTION R/W
WITH TOPSOIL SEGREGATION
54 - REDUCED CONSTRUCTION R/W FOR
NON-WETLAND OR STREAM REASONS
6JJS
11
-2
7-1
7
6H
EI
11
-2
7-1
7IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
7JJS
04
-1
3-1
8
7JJS
04
-1
3-1
8
7H
EI
04
-1
3-1
8IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N - F
ER
C R
EV
IS
IO
N R
EQ
UE
ST
02/09/15
.
.
01
-01
.
.
ST
A. 0
0+
00
T
O S
TA
. 5
8+
66
GR
AN
T D
IS
TR
IC
T, W
ET
ZE
L C
O.,W
.V
.
08/27/18 10:30 AM
.
.
.
.
MVP-STR-006
MVP-STR-005
MVP-STR-647
MVP-STR-002
MVP-STR-003
MVP-STR
-649
MVP-STR-648
MVP-STR-004
MVP-STR-651
MVP-STR-650
MVP-STR-012
MVP-STR-013
MVP-STR-011
MVP-STR-010
MVP-STR-009
MVP-STR-008
MVP-STR-007
S-WX2
S-WX3
MVP-AR-H600-01 ACCESS ROADS, ANCILLARY
SITES, MAINLINE VALVES &
FPCX-H600-001 FOREIGN PIPELINE X-ING PLAN
LAUNCHER/RECEIVER SITES
MVP-QDAR-H600-01ACCESS ROAD DETAIL MAP
MVP-QDAS-H600-01ANCILLARY SITE DETAIL MAP
58+
66
00+
00
2.13,6,15 6,15,53
42+
43
42+
81
4
40'785'
MVP-STR-006
MVP-STR-005
MVP-STR-647
MVP-STR-008
MVP-STR-007
MVP-STR-009
MVP-STR-011
MVP-STR-012
MVP-STR-013
MVP-STR-010
TIME OF YEAR RESTRICTION: NO CLEARING JUNE 1 - JULY 31
SEE TREE CLEARING PLAN FOR FURTHER DETAILS
2
2
5
'
4
0
'
2
5
'
T.O.Y.R.: NO CONSTRUCTION
WITHIN STREAM S-A1a
APRIL 1ST TO JUNE 30TH
TIME OF YEAR RESTRICTION: NO CLEARING JUNE 1 - JULY 31
SEE TREE CLEARING PLAN FOR FURTHER DETAILS
W-TT3
31+
64
34+
89
35+
25
36+
62
3
5
+
9
0
3
7
+
8
1
3
6
+
8
6
35+
53
35+
95
REV. 8
LM
PROPOSED PIPELINE RELOCATION
FPCX-H600-002 FOREIGN PIPELINE X-ING PLAN
FPCX-H600-003 FOREIGN PIPELINE X-ING PLAN
FPCX-H600-004 FOREIGN PIPELINE X-ING PLAN
FPCX-H600-005 FOREIGN PIPELINE X-ING PLAN
MVP-ATWS-735
3,167 SQ FT
CO RTE 15 - N FORK RD
SEE ROAD CROSSING
PERMIT(06-2016-0253)
06-2016-0253 ROAD CROSSING PERMIT
3
80'
2
280'
2
318'
2
410'
46+
59
30+
30
242"O
.D
. X
0.740"W
.T
., X
-70, F
US
IO
N B
ON
DE
D E
PO
XY
342"O
.D
. X
0.888"W
.T
., X
-70, F
US
IO
N B
ON
DE
D E
PO
XY
1793
80
0+
77
3+
32
3 4
TY
PE
4B
T
ES
T S
TA
TIO
N - M
ULT
I. LIN
E F
OR
EIG
N X
IN
G
TY
PE
5
T
ES
T S
TA
TIO
N - M
ET
AL IR
D
RO
P T
ES
T S
TA
TIO
N
2 1
P-W-H600-1100-01 MOBLEY INTERCONNECT
P-W-H600 WEBSTER TAP
P-W-H600-1204-01 CATHODIC PROTECTION
PLOT PLAN
STANDARD DRAWING
EQT HAMMERHEAD TAP
LAT: 39.552177 LON: -80.545615
SEE CONSTRUCTION DRAWING
DWG# P-W-H600-1159-01
RIV
ER
W
EIG
HT
S3
PROPOSED PIPELINE
RELOCATION
T.O.Y.R.: NO CONSTRUCTION
WITHIN STREAM S-A3a
APRIL 1ST TO JUNE 30TH
TIME OF YEAR
RESTRICTION: SEE
TREE CLEARING PLAN
MVP-ATWS-SM-017
38,013 SQ FT
REV.9
IS
SU
ED
F
OR
V
AR
IA
NC
E - A
DD
ED
M
VP
-A
TW
S-S
M-017
08-27-18
HE
I8
FO
R S
LIP
M
IT
IG
AT
IO
N
1+
40
5+
94
Mountain Valley Pipeline, LLC Mountain Valley Pipeline Project
Docket No. CP16-10-000
Rare, Threatened, and Endangered Species Report Attachment 2
Mountain Valley Pipeline Project Variance A-23
October 2, 2018
State and federal agencies identified areas where plant surveys were required. This variance does not occur in any of those areas.
There are no impacts to aquatic resources associated with this variance.
The only avian species-specific presence-absence surveys required for the project are scrub-shrub habitat-specific in the state of Virginia, thus do not apply to this variance area.
The modification of the tree clearing results in a net increase of 0.87 acres MYSO - Known Use Summer Habitat (KUSH). Tree clearing will not occur between April 1 and November 14 as per the BO.
On 02/16/2015, 10/25/2015, Environmental Solutions and Innovations, Inc. (ESI) conducted field surveys to search for portal openings (winter bat habitat). Surveys were conducted in accordance with agency approved protocols for the project. No portal openings were observed in the variance area.
Base Map: ESRI "World Imagery (Clarity)"; accessed 10/3/2018
MVP VarianceMVP LOD (20171127)
ESI Portal Coverage
60 0 60 120Meters
Mountain Valley Pipeline Variance Survey Exhibit; Variance A-23
MYSO - Known Summer Use
Habitat (acres)
MYSO - Known use spring
staging/fall swarming
habitat (acres)
MYSO - Suitable Unoccupied
Summer Habitat (acres)
MYSO - Unknown use spring
staging/fall swarming habitat
(acres)
MYSO - Unknown Use
Summer Habitat (acres)
NLEB known use spring
staging/fall swarming
habitat (acres)Remaining bank acreage from IP-5 table 0.37 1.47 13.04 6.81 13.79 0.59
Bradshaw ATWS 0.02 0.00 0.00 0.00 0.00 0.00
ATWS 1544 0.03 0.00 0.00 0.00 0.00 0.00
ATWS 1545 0.10 0.00 0.00 0.00 0.00 0.00
LY-27 0.00 0.00 0.00 0.00 0.15 0.00
LY-45/46 0.00 0.00 0.00 0.00 0.05 0.00
Variance A-4 - MP 24.6 0.00 0.00 0.00 0.00 0.06 0.00
Bradshaw Slip Repair Phase 1 0.01 0.00 0.00 0.00 0.00 0.00
Variance A-5 - MP 28.97 0.00 0.00 -0.51 0.00 0.09 0.00
Variance H-3 - MP 234.85 0.00 0.00 0.91 0.00 0.00 0.00
Variance F-3 - MP 159.27 0.00 0.00 -0.42 0.00 0.00 0.00
Variance H-2 - MP 240.00 0.00 0.00 0.09 0.00 2.74 0.00
Variance E-4 - LY-058 0.00 0.00 0.00 0.00 0.01 0.00
Variance E-5 - MP 133.46 0.00 0.00 0.27 0.00 0.00 0.00
Variance I-2 - MP-268.8 0.00 0.00 0.00 0.00 0.45 0.00
Variance I-4 - MP 300.7 0.00 0.00 0.00 0.00 0.18 0.00
Variance G-3 - MP 224.1 0.00 0.00 0.00 1.67 0.00 0.00
Variance B-2 - MP 42.7 0.00 0.00 1.45 0.00 0.00 0.00
Variance H-5 - MP 257.9 & 258.2 0.00 0.00 0.39 0.00 0.00 0.00
Variance I-5 - MP 261.47 0.00 0.00 -0.25 0.00 0.00 0.00
Variance H-6 - MP 235.58 0.00 0.00 0.39 0.00 0.20 0.00
Variance F-6 - MP 176.8 0.00 0.00 0.00 0.00 0.08 0.00
Variance D-4 - MP 110.1 0.00 0.00 0.08 0.00 0.00 0.00
Variance E-6 - MP 143.9 0.00 0.00 0.00 0.00 0.08 0.00
Variance F-5 MP 166.07 0.00 0.00 0.24 0.00 0.00 0.00
Variance D-7 - MP 119.0 0.00 0.00 2.64 0.00 0.00 0.00
Variance D-6 - MP 115.74 & 115.85 0.00 0.00 1.22 0.00 0.00 0.00
Variance B-3 - MP 60.29 0.00 0.00 0.01 0.00 0.27 0.00
Variance C-6 - MP 79.46 0.00 0.00 0.00 0.00 -0.21 0.00
Variance C-2 - MP 82 0.00 0.00 0.00 0.00 1.11 0.00
Bradshaw Phase II 0.01 0.00 0.00 0.00 0.00 0.00
Variance A-11 (MP 23.8) 0.00 0.00 0.00 0.00 0.30 0.00
Variance I-10 (MP 266.3) 0.00 0.00 0.00 0.00 -0.64 0.00
Variance A-12 (MP 6.8) 0.01 0.00 0.00 0.00 0.00 0.00
Variance B-7 (MP 60.07) 0.00 0.00 0.00 0.00 1.51 0.00
Variance A-15 (MP 12) 0.00 0.00 0.00 0.00 0.19 0.00
Variance H-7 (MP 238.3) - Transco Credit 0.00 0.00 -11.25 0.00 0.00 0.00
Variance H-7 (MP 238.3) 0.00 0.00 8.37 0.00 0.27 0.00
Variance I-12 (LY-035 Ext) 0.00 0.00 0.00 0.00 0.01 0.00
Variance H-9 (MP 237.5) 0.00 0.00 0.00 0.00 0.24 0.00
Variance D-17 (MP 108.17) 0.00 0.00 4.08 0.00 0.43 0.00
Variance E-10 (MP 149.45) 0.00 0.00 0.00 0.00 0.21 0.00
Variance C-10 (MP 68.4) 0.00 0.00 0.00 0.00 2.34 0.00
Variance C-11 (MP 86.3) 0.00 0.00 0.00 0.00 1.84 0.00
Table 1 Bat Habitat Bank Acreage
MYSO - Known Summer Use
Habitat (acres)
MYSO - Known use spring
staging/fall swarming
habitat (acres)
MYSO - Suitable Unoccupied
Summer Habitat (acres)
MYSO - Unknown use spring
staging/fall swarming habitat
(acres)
MYSO - Unknown Use
Summer Habitat (acres)
NLEB known use spring
staging/fall swarming
habitat (acres)
Table 1 Bat Habitat Bank Acreage
Variance A-14 (MP 6.5) 0.05 0.00 0.00 0.00 0.00 0.00Variance A-14 (MP 6.5) - MVP-WE-014 & ATWSs credit
-12.96 0.00 0.00 0.00 0.00 0.00
Variance A-14 (MP 6.5) - MVP-LY-024 credit -0.86 0.00 0.00 0.00 0.00 0.00
Variance B-10 (MP 35.1) 0.00 0.00 0.34 0.00 0.00 0.00
Variance A-23 (MP 0.10) 0.87 0.00 0.00 0.00 0.00 0.00
Net Remaining Acreage for variances to date 13.09 1.47 4.99 5.14 1.83 0.59
Mountain Valley Pipeline, LLC Mountain Valley Pipeline Project
Docket No. CP16-10-000
Waterbodies and Wetlands Report Attachment 3
Mountain Valley Pipeline Project
Variance A-23
October 2, 2018
On August 23, 2018, Tetra Tech, Inc. (Tetra Tech) surveyed the proposed variance in Wetzel Co., WV for wetlands and streams. Wetland delineations were conducted utilizing the Routine On-Site Determination Methodology presented in the US Army Corps of Engineers (USACE) Wetland Delineation Manual (Technical Report Y-87-1) and the Regional Supplement to the Corps of Engineers Wetland Delineation Manual: Eastern Mountains and Piedmont Region (Version 2.0). During field surveys, Tetra Tech did not identify any wetlands or streams in the variance area as shown on the attached figure.
0.1
0S-TT1
S-ST11S-J63
S-ST10
S-ST12
S-WX2 W-ME1
Mountain Valley Pipeline Project
Data Sources: ESRI Streaming Data 2014.
± NAD 1983 UTM 17N
0
0 100 20050Feet
Docu
ment
Path:
N:\S
tepha
nie.Za
bows
ki\GI
S\Proj
ects\
MVP\
Varia
nce\L
3VAR
-WV-
WE-
30.m
xd
1 inch = 100 feet
Proposed VarianceA-23
Wetzel County, West Virginia
October 2018
LegendIssued forConstruction LODProposed VarianceLimit of DisturbanceCulvertDrainageSeep
Ephemeral StreamIntermittent StreamPerennial StreamPEM Wetland
Proposed Variance
Mountain Valley Pipeline, LLC Mountain Valley Pipeline Project
Docket No. CP16-10-000
Pipeline VarianceRequest MapAttachment 6
!C
!C
!C
0.1
0.0
WV-WE-3877
WV-WE-5163WV-WE-001
WV-WE-4820
WV-WE-4821
WV-WE-001.01
WV-WE-001
WV-WE-001.02Mountain Valley Pipeline Project
Data Sources: ESRI Aerial Imagery, All Issued for Construction data was filed with FERC on 12/20/2017.
October 2018
± NAD 1983 UTM 17N
!C
!C
!C
!C
12
3
Docu
ment
Path:
R:\P
ROJE
CTS\M
OUNT
AIN_V
ALLE
Y_PI
PELIN
E_51
07\VA
RIAN
CE_M
APPI
NG\M
APS\M
VP_V
ARIAN
CES_
MAPB
OOK.
mxd
Legend
!CIssued for ConstructionMilepostIssued for ConstructionRouteIssued for ConstructionLimits of DisturbanceParcel Boundary
Proposed VarianceAdditional TemporaryWorkspace
WETZEL COUNTY
FERC Docket No. CP16-10-000MVP Variance
A-23
0 100 200 300 40050Feet