MPower 3000 Data Sheet

  • Upload
    lnlinfo

  • View
    240

  • Download
    0

Embed Size (px)

Citation preview

  • 8/3/2019 MPower 3000 Data Sheet

    1/12

    Low Energy Door Operator

    Complies with ADA Accessibility Guideline

    MPower 3000

    Copyright 20062009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

  • 8/3/2019 MPower 3000 Data Sheet

    2/129014

    6:C08/01/11

    Copyright2006-2009,2011,SargentMan

    ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve

    d.

    Reproductioninwholeorinpartwithoutth

    eexpresswrittenpermissionofSargentManufacturingCompanyisproh

    ibited.

    1-800-727-5477 www.sargentloc.com

    Table of ContentsMPower 3000 Low Energy Door Operator

    On the Cover

    3000

    Patents: 5,881,497, 7,316,096 and 7,484,333

    MPOWER 3000 Series is the latest generation of power dooroperators. Low energy door operators were once considered anecessity only for those with physical challenges. Today, due tothe populations busy lifestyles, the convenience of hands-freedoor opening is more popular than ever. The patented designof MPOWER 3000 is based on ease and simplicity. MPOWER3000 installs in minutes rather than hours and consists of threebasic components: inverter, motor and closer body.

    What separates MPOWER 3000 Series from other operators isits ability to function as a standard door closer. When the door is

    opened manually, there is little resistance and the drive train andmotor are not engaged. The closer, not the motor, controls theclosing cycle. Since the door closer does not back-drive the motorduring the closing cycle, there is no loss of closer efficiency. In theevent of a power outage, the door can be manually opened andwill close via the door closers spring force.

    MPOWER 3000 Series is listed with UL and ANSI/BHMA A156.19and meets the requirements of ADA and ANSI/BHMA 156.4.MPOWER 3000 is ideal for doctors offices, retirement facilities,schools, churches, and any location where noise is a majorconcern and special features are not a requirement. MPOWER3000 can be activated via wall switch, radio frequency device ormotion sensor, and is available for push or pull side applications.Based on its dual functionality, ease of use and quiet operation,MPOWER 3000 Series offers the customer a unique choice!

    Note: Any retrofit or other field modification to a fire ratedopening can potentially impact the fire rating of the opening, andSargent Manufacturing Company makes no representations orwarranties concerning what such impact may be in any specificsituation. When retrofitting any portion of an existing fire ratedopening, or specifying and installing a new fire-rated opening,please consult with a code specialist or local code official(Authority Having Jurisdiction) to ensure compliance with allapplicable codes and ratings.

    Overview & Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

    Standard Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

    How to Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

    T y p i c a l D o o r T r a f f i c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    S w i t c h e s & R F P a r t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    Typical System Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    Technical Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    Architectural Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

  • 8/3/2019 MPower 3000 Data Sheet

    3/1211-800-727-5477 www.sargentloc.com

    Overview & CertificationsMPower 3000 Low Energy Door Operator

    Ease of installation and setup- Simple instructions

    Application versatility and ease of adjustment- Push or pull side mounting units available

    Operates as mechanical surface closer during close cycles,when door is opened manually or if power is turned off

    - Quiet operation- Spring force provides the feel of a normal manual

    door closer- Door can be opened manually if desired

    SARGENT 1130 series door closer- Adjustable Spring Power- Backcheck Valve- Sweep Valve & Latch Valve

    Non-handed

    Unit Activation Options- Wall switches- Radio frequency device

    End-User On/Off Switch

    Hold open options- 0-30 seconds (5 seconds minimum required for ADA and

    ANSI/BHMA A156.19)

    Obstruction detection- Motor stops if door is obstructed during an opening- Door closes under manual spring force (not to exceed

    15lbf)

    Push and Close- Allows the operator to skip the hold open time

    when it is not necessary or required- Adjustable door sensitivity

    Overload Safety Shut-Off- After two minutes of receiving a door activation

    signal, the inverter will time out and close the door- Prevents motor/inverter damage

    Motor Start Delay for Locking Hardware- 0-5 second delay to allow locking hardware to release first

    Features & Functions

    Power Input; 120 VAC, 60Hz

    Current Draw: .6A or .3A

    Relay Output: DPDT- Normally Open/Normally Closed (jumper)

    - For electric strike function

    Electrical Data

    C-UL US listed for use on fire and smoke barrier doors

    2-year warranty (refer to current SARGENT price bookfor terms & conditions)

    Meets requirements for Americans with Disabilities Act (ADA)

    ANSI/BHMA A156.19 certified

    Meets ANSI/BHMA A156.4 requirements

    Certifications

    InverterMotor

    1130 Closer Body

  • 8/3/2019 MPower 3000 Data Sheet

    4/129014

    6:C08/01/11

    Copyright2006-2009,2011,SargentMan

    ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve

    d.

    Reproductioninwholeorinpartwithoutth

    eexpresswrittenpermissionofSargentManufacturingCompanyisproh

    ibited.

    21-800-727-5477 www.sargentloc.com

    Standard ApplicationsMPower 3000 Low Energy Door Operator

    Standard Applications

    3060

    Hinge (Pull) Side of Door

    Adjustable Stop 180 swing (trim permitting)

    Minimum Door widthSingle Door - 29" (74cm)Double Door - 30" (76cm)

    An auxiliary stop is suggested where severe conditions exist.

    NOTE: Contact factory for use on doors exceeding 250 lbs.

    3051Stop (Push) Side of Door

    Standard Duty Double Lever Arm Frame reveals 2-5/8" to 6-3/4" (67-171mm) An auxiliary door stop is required for these applications 170 swing (trim permitting)

    NOTE: Contact factory for use on doors exceeding 250 lbs.

  • 8/3/2019 MPower 3000 Data Sheet

    5/1231-800-727-5477 www.sargentloc.com

    How to OrderMPower 3000 Low Energy Door Operator

    Note: Door switches and sensors are not included with the MP3000Series Door Operators. These items must be ordered separately.

    SARGENT

    DesignationDescription

    BHMA

    Designation

    EN Sprayed Aluminum 689

    EB Sprayed Bronze 690

    EAB Sprayed Brass 696

    3051 x finish

    For stop (push) side of the door withdouble lever arm for reveals 2-5/8" to6-3/4" to swing up to 170

    3060 x finish

    For hinge (pull) side of the door withrigid arm & slide track for a maximumreveal of 1/8" to swing up to 180

    How to Order:

  • 8/3/2019 MPower 3000 Data Sheet

    6/129014

    6:C08/01/11

    Copyright2006-2009,2011,SargentMan

    ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve

    d.

    Reproductioninwholeorinpartwithoutth

    eexpresswrittenpermissionofSargentManufacturingCompanyisproh

    ibited.

    41-800-727-5477 www.sargentloc.com

    Typical Door TrafficMPower 3000 Low Energy Door Operator

    APPLICATION DAILY AVERAGE YEARLY AVERAGE USAGE OPERATOR

    Executive Office

    ADA Dorm Room

    ADA Hotel orRetirement Home Room

    Assisted Living Up to 100 Up to 22,000 Low Low EnergyCommon Area Door

    Office/Warehouse Door

    ADA Auxiliary Entrance

    ADA Accessible Restroom

    Government/Public Restroom 300 108,000

    Hospital Corridor Door 600 220,000

    Office Building Entrance 1,200 450,000 Moderate

    Airport Entrance 3,000* 1,100,000

    Large Office Building Entrance 4,000* 1,200,000

    Large Dept. Store Entrance 5,000* 1,500,000

    * Representspowered cycles

    Note: The above applications and data are examples for guidance only. Contact your

    ASSA ABLOY Door Security Solutions Sales Representative or SARGENT Technical Consultantto confirm the suitability of your specification and system design.

    Typical Door Traffic Categories

    Moderate

    MP3000

    Besam HighEnergy Door

    Operator

    High

    MP4000 LowEnergy

  • 8/3/2019 MPower 3000 Data Sheet

    7/12

    REED SWITCH

    CHAIN63-0781

    RF POWER SUPPLY

    BREAKER SWITCH

    (optional)

    OPEN / CLOSE POSITIONING ASSEMBLY63-4293

    PINION EXTENSION / CLUTCH ASSEMBLY63-4295

    1130 SERIES

    CLOSER BODYMOTOR ASSEMBLY

    63-4294

    POWER SWITCH63-0783 BACKPLATE

    INVERTER

    63-0784

    51-800-727-5477 www.sargentloc.com

    Parts ListMPower 3000 Low Energy Door Operator

    63-4287 - Arm and Track Assembly63-4288 - Arm Assembly63-4289 - Track Assembly

    63-4290 - Standard Arm Assembly63-4291 - Arm Assembly less Rod

    and Shoe63-4292 - Foot Assembly

    Arm and Trac Assemblies

    COVER63-0780

    Parts List

  • 8/3/2019 MPower 3000 Data Sheet

    8/129014

    6:C08/01/11

    Copyright2006-2009,2011,SargentMan

    ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve

    d.

    Reproductioninwholeorinpartwithoutth

    eexpresswrittenpermissionofSargentManufacturingCompanyisproh

    ibited.

    61-800-727-5477 www.sargentloc.com

    Switches and RF PartsMPower 3000 Low Energy Door Operator

    SARGENTMODEL DESCRIPTION VIEW NOTES

    4396HP

    6" x 6" Squarewall switch

    with handicap

    logo & Pressto Open

    Momentary SPDT contacts rated at500ma @ 12 VDC or 24 VAC

    Mounts in standard single or double gangelectrical box or in 6-1/2" x 6-1/2" x 1-3/4"surface mount box provided

    Wireless Switch Option:- Operates at 433MHz- Operator requires RF receiver (#RFR1)- Switch is to be surface mounted in box provided- Specify RF to switch number to order

    (Ex: 4395HPRF)

    4396P6' x 6" Square

    wall switch withPress to Open

    4395HP

    6" Roundwall switch withhandicap logo &Press to Open

    4395P6" Round

    wall switch withPress to Open

    FOB1Key Fob

    Transmitter 433MHz Key Fob used with RF Receiver

    RFR1 RF Receiver Radio Frequency Receiver (433 MHz) 24 VDC power supply Activation switches not included.

    4397HPNarrow type

    switch

    Mounts flush through a 1-3/4" x 2-7/8" cutout injamb or in the 4-3/4" x 2" x 1-7/8" box provided

    Momentary SPDT contacts rated at500ma @ 12 VDC or 24 VAC

    43411" x 3/4"

    Surface MountPushbutton

    Surface mount push button Momentary DPST contacts rated at 3 Amps

    43992" Square

    GreenPushbutton

    Single gang push button with green LED Momentary SPDT contacts rated at 10 Amps

    Accessories

    Supplied with each MP3000 is the 63-4306 Signage Kit which containstwo of each of the three labels shown above

  • 8/3/2019 MPower 3000 Data Sheet

    9/1271-800-727-5477 www.sargentloc.com

    Typical System ApplicationsMPower 3000 Low Energy Door Operator

    ACCESS CONTROL FOR ENTRYOpening Description: Fail SecureADA Opening Electric Strike &Door Operator

    ApplicationRated or Non-Fire Rated Metal Door Interior or Exterior Office, Main Entranceor Stairwell Openings

    Operation Activate or deactivate system by a key

    control switch When outside, door switch is inactive,

    ingress will be by Pin or Prox only Inside door switch will unlock

    and open the door automatically Push exit device bar to exit at

    all times

    Door operator acts as standarddoor closer when entering orexiting manually

    Material SARGENT MPower 3000 Door Operator SARGENT 8900 Mortise Exit Device 2-SARGENT 4396HP Door Switches SARGENT 4370L Maintained Key Switch SARGENT 4293 Wall Prox Card Reader HES 1006 Electric Strike 1- 12 VDC or 24 VDC Regulated and

    Filtered Power Supply Dual out put timer by others

    120 VAC

    ELECTRIC STRIkESOpening Description: Fail Secure ADAOpening Double Electric Strike & DoorOperators on Pair of Doors

    ApplicationInterior, Non-Fire Rated Wood or Metal

    Doors Corridor or Emergency RoomOpenings

    Operation Doors are to be closed and latched at

    all times Key Switch activates and deactivates

    door switches to signal door operators Active door switch will energize the

    electric strike and automaticallyopen doors

    Door operators will act as standarddoor closers when entering or exitingmanually

    Material 2-SARGENT MPower 3000 Door

    Operators

    FOLGER ADAMS 310-4-1 Double ElectricStrike

    2-SARGENT 8700 Surface Vertical RodExit Devices

    2-SARGENT 4396HP Door Switches SARGENT 4370L Maintained Key Switch SARGENT 4293 Wall Prox Dual output timer by other

    120 VAC

    MAGNETIC LOCkOpening Description: Fail SafeADA Opening - Magnetic Lock &Door Operator

    ApplicationNon-Fire Rated Glass Door -Interior or Exterior Office or MainEntrance Openings

    Operation Lock or unlock system by a key control

    switch at all times Free ingress & egress using thedoor operator or manuallywhen unlocked

    Outside door switch will be inactivedenying ingress other than by Pin orProx when locked

    To exit, inside door switch will unlockmagnetic lock and open the door ormanually push bar to exit

    Door operator acts as standard doorcloser when entering or exiting manually

    Material SARGENT MPower 3000 Door Operator SARGENT 1584 Electromagnetic Lock McKINNEY QC4 Electric Hinge SARGENT 55-8895 Mechanical Touch

    Bar with Switch

    2-SARGENT 4396HP Door Switches SARGENT 4370L Maintain Switch SARGENT 4293 Wall Prox

    120 VAC

    Note: Not available for use with latch retraction exit devices

  • 8/3/2019 MPower 3000 Data Sheet

    10/129014

    6:C08/01/11

    Copyright2006-2009,2011,SargentMan

    ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve

    d.

    Reproductioninwholeorinpartwithoutth

    eexpresswrittenpermissionofSargentManufacturingCompanyisproh

    ibited.

    81-800-727-5477 www.sargentloc.com

    Technical DetailsMPower 3000 Low Energy Door Operator

    Circuit breaker

    Activation switch terminal Relay terminal

    POT DESCRIPTION

    H/O TQMotor Torque at Hold OpenPosition

    REV SPD Motor Reversing Speed

    M/DLY Motor Delay on Opening

    H/O TM Hold Open Time (5 - 30 Seconds)

    OBSTR SENS Obstruction Detection on Open

    PUSH SENSE Push Recognition Sensitivity

  • 8/3/2019 MPower 3000 Data Sheet

    11/1291-800-727-5477 www.sargentloc.com

    Architectural SpecificationsMPower 3000 Low Energy Door Operator

    General Specifications

    2.0 Low Energy Door Operators

    A. Door Controls____ (interior) (exterior) swinging door(s) shall be of rack and pinion design contained within a precision castaluminum housing.

    B. Door closing force shall be adjustable to ensure adequate closing control.

    C. Door closing speed shall be controlled by independent hydraulic adjustment valves in the sweep and latch range of the closing cycle.

    D. Door Operator shall provide conventional door closer opening forces unless the power operator motor is activated.

    E. Door Operator shall provide conventional door closing forces at all times except in the event of power outage duringpowered door open cycle.

    F. Door Operator opening force and speed shall be adjustable by independent electronic adjustment to ensure adequateopening control per accessibility codes.

    G. Door Operator shall have an adjustable hydraulic backcheck valve to cushion the door speed if door is opened violently.

    H. Door Operator shall have a manual adjustment to locate both full open and full closed door positions.

    I. Maximum door open shall be adjustable and capable to a maximum 180 conditions permitting.

    J. Door Operator shall be SELECTIVELY ACTIVATED by external initiating device, i.e., wall switch, etc.

    K. Door Operator shall be both AUTOMATICALLY ACTIVATED and SELECTIVELY ACTIVATED.

    L. Door operator shall have adjustable hold open time capability in range from 5 to 30 seconds.

    K. Door operator shall have input line rating of 120VAC, .6A or 240VAC, .3A.

    M. Units shall have relay contact for interfacing products having a contact rating of 30VDC at 1A or 125VAC at .5A.

    N. Unit shall have an external On/Off Switch to defeat powered opening when desired.

    O. Unit shall have an internal circuit breaker switch to interrupt input power for servicing.

    P. Unit shall be U.L. Listed for automatic closing door.

    Q. Unit shall be in compliance with the requirements of the Americans With Disabilities Act (ADA), ANSI standards A117.1 andA156.19. Unit shall meet C-UL US.

    Additional Detailed SpecificationsA. When activated, the unit shall, by means of an integral motor and chain drive, power open the door at both a speed and force

    that are adjustable to meet accessibility codes.

    B. The door shall be powered from a door closed position to a full door open position and remain in momentary hold openfor ___seconds (adjustable 0 to 30 seconds) [(Unit shall power open door to full open position up to 180 (3060); 170(3051), conditions permitting.) (Unit shall be capable of allowing the door to be opened manually from 0 to 180, conditionspermitting.)]

    C. Once unit reaches full hold open position, if reinitiated, units momentary hold open time shall restart from the initially sethold open time.

    D. If unit is initiated during the closing cycle, unit shall revert to opening cycle beginning at that door position.

    E. Obstruction detection on open shall neutralize and reverse motor action reverting motor to closed position thus allowingdoor to close under closer spring force only.

    F. This obstruction detection feature shall be integral to unit.G. During closing cycle, the unit shall close door under spring power not to exceed a closing force of 15 lbf.

  • 8/3/2019 MPower 3000 Data Sheet

    12/12

    90146 C 08/01/11

    SARGENT Manufacturing Company100 Sargent Drive, New Haven, CT 06511 USA800-727-5477 www.sargentlock.com

    Founded in the early 1800s, SARGENT is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The companys customer base includes commercial construction, institutional, and industrial markets.

    Copyright 2006-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

    ASSA ABLOY is the global leader in door opening solutions, dedicated to

    satisf ing end ser needs for sec rit safet and con enience