Motor Drive 3

Embed Size (px)

Citation preview

  • 8/6/2019 Motor Drive 3

    1/13

    EXPERT SYSTEMS AND SOLUTIONS

    Email: [email protected]

    [email protected]

    Cell: 9952749533www.researchprojects.info

    PAIYANOOR, OMR, CHENNAI

    Call For Research Projects Final

    year students of B.E in EEE, ECE, EI,

    M.E (Power Systems), M.E (Applied

    Electronics), M.E (Power Electronics)

    Ph.D Electrical and Electronics.

    Students can assemble their hardware in our

    Research labs. Experts will be guiding theprojects.

  • 8/6/2019 Motor Drive 3

    2/13

    SCADA FOR INDUSTRIAL DRIVES

    UNDER THE GUIDENCE OF

    Mr.T. Sree Ranga Raja M.E

    (Teaching Research Associate)

  • 8/6/2019 Motor Drive 3

    3/13

    Computer

    l

    rm

    Supervi

    or

    emote Termi

    l U it

    t

    Stor

    ge

    3-

    e

    i e

    C

    i e

    i ro

    roce or

    .C P .C

    PLC

    C

    chi

    e

    3-Phase

    achi

    es

  • 8/6/2019 Motor Drive 3

    4/13

    PROJECT WORK PLAN

    MINI PROJECT

    100 Relay controller Real Time Scanner

    Micro-procesor based

    ADC

    Parallel Port Decoder D.C drive control

    characters

    MAIN PROJECT

    Micro-processor baseddrive control

    Serial communication

    using C

    PSPICE simulation ofA.C machine

    DAC and ADC in data

    acquisition

  • 8/6/2019 Motor Drive 3

    5/13

    MICROPROCESSOR BASED FIRING UNIT+12V

    +12V

    +12V

    +12V

    +12V

    +12V

    +12V

    -12V

    +12V

    +12V

    -12V

    -12V

    -12V

    230VAC

    D1D2

    D3 D4

    C11000

    25V

    C2

    +

    -

    +

    -

    R15

    10K

    R16

    2.2KR17

    2.2K

    R18

    10K

    25V1000

    IC3

    7812

    7912

    IC32

    1

    3

    1

    2

    3

    D7

    D8

    R191K

    R20

    1K

    R24

    6.8K

    R23

    1K

    C4116V

    C31 16V

    R22

    1K

    R21

    6.8K

    IC6

    555

    IC7555

    R25

    68

    0.5W

    R2768

    0.5W

    D12

    D13

    D9 D11

    D14

    R2810K

    R2610K

    G1

    G2

    X1

    230V AC PRI

    15V-0-15V SEC

    500mA TRANSFORMER X2

    X3

    R1

    250K

    VR1

    470K

    VR2100K

    R210K

    0-5V

    INP

    T

    R310K

    R6

    10K

    IC1

    a

    IC1

    c

    IC1b

    T12N2222

    IC1

    LM324

    R7

    47S1

    R8

    500

    R9100K

    D5

    R1010K

    R11

    10K

    1/21C2

    LM747 R1310K

    1/2 IC2

    LM747

    D6 R1418K

    4-20 mA

    INP

    T

    R410K

    R12

    10KCONTROLVOLTAGE

    LM747

    1/2 IC5

    1/2 IC5LM747

    10K

  • 8/6/2019 Motor Drive 3

    6/13

    HighPowerGatePulses

  • 8/6/2019 Motor Drive 3

    7/13

    PHASE CONTROLLER

    CIRCUIT

  • 8/6/2019 Motor Drive 3

    8/13

    Observation 1

    To turn a thyristor ON, a gate current >Igtmust be applied until the load current isgreater than or equal to load current.

    For industrial application this condition mustbe meet at the lowest expected operatingtemperature

    Use an resistor o f 1K of lower value between gate and

    cathode

  • 8/6/2019 Motor Drive 3

    9/13

    Observation 2

    To turn off a thyristor the load current must

    be

  • 8/6/2019 Motor Drive 3

    10/13

    Observation 3

    In most of the industrial there is a very high electrical

    noise these noises may result in false triggerring of

    triacs

    Make gate connections as small as possible

    The gate sensitivity can be reduced by adding 1 K

    ohms between the gate and and MT1.-

    use shielded cable

    H triac can also be used ( e.g BT 139 -600H)

  • 8/6/2019 Motor Drive 3

    11/13

    Observation 4

    When the drives are used in industrial

    application with highly capacitive loads it

    high dv com/dt or dv / dt are likely to causeproblems in these cases it is better to use an

    RC snubber across MT1 and MT2 .

  • 8/6/2019 Motor Drive 3

    12/13

    Observation 5

    A very high di com / dt is observed when the

    drive unit is intended to feed a transformer or

    an auto-transformer load , starting ofinduction machines .

    Use an inductor of few mill henry in series

    with the load

    Industries may employ HI-COM triacs

  • 8/6/2019 Motor Drive 3

    13/13

    REFERENCES

    A Distribution System Automation Laboratory For undergraduate

    Education IEEE Transaction on Power Systems Department of

    Electrical Engineering ,National Taiwan university

    Distribution Management System : Function and Payback IEEE

    Transaction on power Systems

    Concise notes On SCADA Systems ofChennaiCityControlCenter

    TNEB invited talks CIRE

    High frequency DC:DCpower conversion: Theinfluenceof

    package parasitics

    -by Mark Pavier, Andrew Sawle, ArthurWoodworth,

    Ralph Monteiro, Jason Chiu, Carl Blake

    CDV/DTInduced Turn-On In Synchronous BuckRegulators

    -by ThomasWu International Rectifier

    Dallus Semi Conductors - Application Note 206 - Using a PCs

    RS232 Serial Port To Communicate with 2-Wire Devices