Autoranging from –148°F to +68°F RS232/485 outputs °F, °C, and ppmv units Calibration traceable to NIST Remote sensors available Moisture / Dew Point Hygrometers Features & Benefits MM400 Advanced technologies in process gas measurement for maintenance free analysis. Utilising a state of the art ceramic sensor the MM400 offers excellent long-term reliable and stable moisture analysis from trace levels to ambient air conditions. Fast response and recovery from saturation Fault alarm Intrinsically Safe Option Applications Industrial specialty Gases Heat Treating Furnaces Air Dryers Chemical Manufacturing Compressed Air Natural Gas Plastics Manufacturing Inert Atmosphere Blanketing Metallurgy Approved by BASEEFA and CENELEC to ATEX II 1G EEX ia IIC T4 standards

Moisture Analyzer MM400

Embed Size (px)

Citation preview

Page 1: Moisture Analyzer MM400

Autoranging from –148°F to +68°F

RS232/485 outputs

°F, °C, and ppmv units

Calibration traceable to NIST

Remote sensors available

Moisture / Dew Point Hygrometers

Features & Benefits

MM400

Advanced technologies in process gas measurement for maintenancefree analysis. Utilising a state of the art ceramic sensor the MM400offers excellent long-term reliable and stable moisture analysis fromtrace levels to ambient air conditions.

Fast response and recovery fromsaturation

Fault alarm

Intrinsically Safe Option

Applications

Industrial specialty Gases Heat Treating Furnaces Air DryersChemical Manufacturing Compressed Air Natural GasPlastics Manufacturing Inert Atmosphere Blanketing Metallurgy

Approved by BASEEFA and CENELEC to ATEX II 1G EEX ia IIC T4 standards

Page 2: Moisture Analyzer MM400

The MM400 can be configured in 3 differentcabinets. The sensor can be remotemounted from any of these configurations.

Both general purpose and intrinsically saferemote sensors are available:

Three different configurations to match yourneeds:

Panel or bench mount

NEMA 4X / IP66 waterproof andweatherproof

19" rack mount

Analog OutputsAlarmsRemote Sensors

All instruments in the series incorporate ourhigh quality aluminium oxide moisturesensor, providing accurate, dependableresults over a wide range from –148°F to+68°F dew point. The aluminium oxidesensor is maintenance-free and is thepopular choice for the most demandingapplications.

Simply select the instrument configurationand sensor location and let the analyzer dothe rest.

The Systech Illinois 400 Moisture/DewPoint Hygrometers represent the latestadvance in moisture analysis. Designed tobe customized to your application givingprecise measurements while providing asimple, yet affordable analyzer.

Cabinetry & Mounting

Options

Combine the MM430 with any of ouroxygen or carbon dioxide analyzers tocreate a dual gas analyzer. Both units fitinto a 19" rack mountable cabinet.

Versatile Configurations

Maintenance Free

MM410

MM420

MM430

This series is designed with the user inmind. These units are completelyconfigurable including the ability to remotemount sensors and offering user-selectableunits of Dew Point (°C or °F) or ppmv.

Two versions of the remote sensor areavailable to meet your needs. The generalpurpose sensor includes flow valves andcan be mounted up to 3280.8ft from theanalyzer. A simple coaxial cable connectsthe sensor to the instrument.

The intrinsically safe remote sensor allowsfor installations into hazardous areas. Thissensor is approved by BASEEFA andCENELEC to ATEX II 1G/EEx ia IIC T4standards.

A small, anodized aluminium strip iscoated with a very thin layer of gold.The aluminium and gold layers form the twoelectrodes of an aluminium oxide capacitor.The water vapor penetrates through thegold layer and adheres to the pores of theoxide layer. The number of moleculesabsorbed on the oxide layer determines theconductivity of the oxide. The value of porewall resistance provides a value ofimpedance which is directly related to thewater vapour pressure.

All Systech Illinois sensors are made tolaboratory standards of precision andindustrial standards of durability.

Stainless steel housings, lab gradecomponents and controlled environmentmanufacturing ensure the finest, mostconsistently precise sensors in the industry.

Custom Configuration Principle of Operation

Performance Guaranteed

MM411

Generalpurpose sensor

Intrinsicallysafe sensor

Water vapour molecules permeategold emulsion to change the sensor’scapacitance in relation to the dewpoint of the sample gas stream.

Permeable Gold Coating

Porous AluminiumOxide Interlayer

AluminiumSubstrate

PTFE Insulation

Page 3: Moisture Analyzer MM400

Systech Illinois reserve the right to change specifications without notice. 2010/09

Illinois Instruments, Inc (U.S)2401 Hiller Ridge RoadJohnsburg, Illinois 60051U.S.ATel: +1 815 344 6212Fax: +1 815 344 6332E-mail: [email protected]

Systech Instruments Ltd (UK)17 Thame Park Business Centre,Wenman Road,Thame, Oxfordshire OX9 3XATel: +44 (0)1844 216838Fax: +44 (0)1844 217220E-mail: [email protected]

Illinois Instruments (Thailand)6th fl Nopnarong Bldg No7Ladprao23, Jatujak, Bangkok 10900ThailandTel: +66 (0)2938 0798Fax: +66 (0)2938 1058E-mail: [email protected]

Systech Illinois (China)Room 519, No.3 FuCheng BuildingNo. 900 Quyang Rd, Hongkou district,Shanghai, China 200434Tel: +86 21 65533022Fax: +86 21 65539651Email: [email protected]

MM410Bench/Panel Mount7.48H x 9.33W x 16.14D (inches)17.41lbs

MM420IP66/NEMA 4XWall Mount/Weatherproof15.9Hx12.91Wx7.08D (inches)28.8 lbs

MM430Rack Mount 4UHouses 1 or 2 analyzers7H x 19.05W x 16.14D (inches)21.38 lbs (single unit)

Measurement Ranges

Accuracy

Response Time

Selectable Units

Display Type

Operating Conditions

Sample Connections

Sample Pressure

Sample Flow

Power Requirements

Unacceptable Gases

Options

Analog Outputs

High / low alarms

19” Rack Mount

Remote Mounted Sensors

MM400 - Moisture / Dew Point Hygrometers

Systech Illinois have over 25 years experience of providing analysis solutions for a widerange of industries. From our manufacturing plants in the U.S and UK we produce gasanalyzers for industrial process industries, headspace analyzers for monitoring gas flushingof food products, and our range of permeation analyzers.

Technical Specifications

Autoranging from -148°F to +68°F and equivalent in ppm(v) moisture

±1°F from -76°F to +68°F (±1°C from -60°C to +20°C)±2°F from -148°F to -76°F (±2°C from -100°C to -60°C

Wet gas to dry gas: -4°F to -76°F (-20°C to -60°C), less than 60 secondsDry gas to wet gas: -148°F to -4°F (-100°C to -20°C), less than 60 seconds

Dew Point °C / Dew Point °F / ppm(v)

5 digit high visibility LED

Sample and ambient temperature: 32–104°F (0–40°C)

1/8 in. Swagelock® type, brass

0.25 – 28.0 Barg

Independent: ideally 0.5 l/min

115/230 VAC, 50/60 Hz

Corrosive gases, Mercury, Ammonia, Chlorine, HCl, Ozone

Scaleable 0 - 10V, 0 - 100mV and 4 - 20mA all isolated

2 Voltage free with changeover contacts rated 240V 3A

Can be combined with many of our other products in a 19” rack mountconfiguration

General Purpose Sensors can be remote mounted up to 3280.8 ft away.Intrinsically Safe Sensors can be mounted up to 656 ft away.