28
: ADVANCED ARCHITECTURAL PRODUCTS www.SMARTciSystems.com 1 (269) 355-1818 SMARTci SMARTER BY DESIGN. PROVEN BY PERFORMANCE. SMARTci+ System

METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
OPTIONAL CAVITY BATT INSULATION (BY OTHERS)
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4"-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON METAL (OR WOOD) FRAMING / MASONRY WALL ASSEMBLY (BY OTHERS)
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
OPTIONAL INTERIOR VAPOR RETARDER (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
WALL SECTION
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
0
Page 2: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
BLOCKING AS REQ'D (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRTS AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
TWO " MIN. HORZ. BEADS OF 14" MIN. HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
PARAPET FLASHINGS / MEMBRANES (BY OTHERS)
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTCI ANGLE
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
PARAPET DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
1
Page 3: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GRADE
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN THE STARTING INSULATION PANEL AT THE FOUNDATIONS
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
14" MIN. TWO HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
FOUNDATION NOTCH DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
2
Page 4: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GRADE
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN THE STARTING INSULATION PANEL AT THE FOUNDATIONS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
14" MIN. TWO HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID CUSTOM-PROFILED RIGID CUSTOM-PROFILED RIGID RIGID RIGID INSULATION PANEL
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
FOUNDATION FLUSH DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
3
Page 5: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

15

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
FASTEN OUTSIDE ANGLE @ EVERY GREENGIRT; SHIP LAP MIN. 1" W/MIN. " 14" BEAD OF APPROVED SEALANT AT ALL ANGLE LAPS, TYP.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE FASTENERS, MAX. 16" O.C., LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID CUSTOM-PROFILED RIGID CUSTOM-PROFILED RIGID RIGID RIGID INSULATION PANEL
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
INSIDE CORNER DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
4
Page 6: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

15

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. BEADS 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
FASTEN OUTSIDE ANGLE @ EVERY GREENGIRT; SHIP LAP MIN. 1" W/MIN. 14" BEAD OF APPROVED SEALANT AT ALL ANGLE LAPS, TYP.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
OUTSIDE CORNER DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
5
Page 7: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
TWO " MIN. CONTINUOUS HORZ. BEADS 14" MIN. CONTINUOUS HORZ. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS HORZ. BEAD BEHIND ALL HEADER ANGLES, TYP.
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
@ OPENING HEADERS: APPLY SMARTci TAPE TO INSULATION PANEL, LAP OVER GREENGIRT TO AIR SEAL RIB, BEFORE INSTALLING THE NEXT PANEL ABOVE
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN STARTING INSULATION PANELS
AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
HEADER DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
6
Page 8: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING SMARTci 4" SEALING 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. BEADS 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS VERT. BEAD BEHIND ALL JAMB ANGLES, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
JAMB DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
7
Page 9: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
TWO " MIN. CONTINUOUS HORZ. BEADS 14" MIN. CONTINUOUS HORZ. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS HORZ. BEAD BEHIND ALL SILL ANGLES, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
CUSTOM FIELD-CUT SMARTci RIGID SMARTci RIGID INSULATION PANEL, TO FIT BELOW , TO FIT BELOW SILL ANGLE
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SILL DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
8
Page 10: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SHIP LAP 4" SMARTci SEALING TAPE AT ALL SOFFIT EXTERIOR CORNERS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING SMARTci 4" SEALING 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN STARTING INSULATION PANELS
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. HORZ. BEADS OF 14" MIN. HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT OUTSIDE DETAIL-1
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
9
Page 11: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT INSIDE DETAIL-1
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
10
Page 12: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS BEADS OF 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
SHIP LAP 4" SMARTci SEALING TAPE AT ALL SOFFIT EXTERIOR CORNERS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING SMARTci 4" SEALING 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN STARTING INSULATION PANELS
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT OUTSIDE DETAIL-2
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
11
Page 13: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

15

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4" #14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
ATTACHED AT EVERY GREENGIRT
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT INSIDE DETAIL-2
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
12
Page 14: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F2
AutoCAD SHX Text
15
AutoCAD SHX Text
F4
AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F1
AutoCAD SHX Text
15
AutoCAD SHX Text
F1
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F3
AutoCAD SHX Text
15
AutoCAD SHX Text
F3
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
MIN. 22 GAUGE METAL 1 1/2" x 1 1/2" ANGLED RETENTION CLIPS, MAX 24" O.C.
AutoCAD SHX Text
MIN. 22 GAUGE CONTINUOUS GALVANIZED STEEL 1 3/4" X 4 1/4" ANGLE CORNER 1 3/4" X 4 1/4" ANGLE CORNER ANGLE CORNER CLOSURE, FASTENED AT EVERY GREENGIRT
AutoCAD SHX Text
NOTE! REQUIRED ACCESSORIES AND METAL FLASHINGS MUST BE USED WITH THIS SYSTEM. THESE COMPONENTS CAN BE MANUFACTURED AND / OR PROVIDED BY ADVANCED ARCHITECTURAL PRODUCTS, OR BY THE CUSTOMER. THEY ARE NOT OPTIONAL, AND ARE NECESSARY FOR THE PROPER INSTALLATION AND FUNCTION OF THE SYSTEM. PLEASE CONTACT AN A2P SALES REPRESENTATIVE WITH ANY QUESTIONS, FOR PRICING INFORMATION, OR TO INQUIRE ABOUT CUSTOM-SIZED METAL FLASHINGS AND ACCESSORIES. GREENGIRTS AND CUSTOM-PROFILED RIGID INSULATION PANELS ARE PROVIDED FOR THIS PROJECT AS A THERMALLY-BROKEN COMPOSITE SUB-FRAMING SYSTEM AND CONTINUOUS INSULATION. THIS SYSTEM DOES NOT INCLUDE MOISTURE DRIVE DESIGN OR VAPOR BARRIER DESIGN AND PLACEMENT. WEATHER PROOFING, RESISTANCE AND / OR WATER TIGHTNESS IS THE SOLE RESPONSIBILITY OF OTHERS. PROPER FLASHINGS & COUNTER FLASHINGS MUST BE INSTALLED BY OTHERS, AND IT IS RECOMMENDED THAT PROVEN CONSTRUCTION BEST PRACTICES BE FOLLOWED AT ALL TIMES. DO NOT INSTALL ANY A2P PRODUCT UNLESS CARE HAS BEEN TAKEN TO REVIEW ALL OF THE DOCUMENTS RELEVANT TO THE PRODUCT INSTALLATION, AND PROPER TRAINING HAS BEEN COMPLETED. ALWAYS DEFAULT TO ARCHITECT'S DETAILS AND DESIGN INTENT! DETAILS ARE PROVIDED FOR INFORMATION ONLY, AS IT PERTAINS TO INSTALLING DETAILS ARE PROVIDED FOR INFORMATION ONLY, AS IT PERTAINS TO INSTALLING GREENGIRT. SPECIFIC PROJECT ENGINEERING (BY OTHERS) WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. ALWAYS REVIEW LOADING REQUIREMENTS WITH THE PROJECT ENGINEER, AND USE APPROPRIATE FASTENERS AND SPACING. USE PLASTIC HORSESHOE SHIMS WHERE REQUIRED TO ACHIEVE ± 1/16" DEFLECTION; MAX. SHIM DEPTH IS 1/4". USE SPRAY FOAM AT ALL VOIDS TO ENSURE CONTINUOUS INSULATION. DO NOT USE IMPACT HAMMERS, IMPACT DRILLS OR SIMILAR TOOLS TO INSTALL GREENGIRT! ADVANCED ARCHITECTURAL PRODUCTS MAKES NO CLAIMS OR GUARANTEES ABOUT ANY ITEMS MANUFACTURED BY OTHERS. ADVANCED ARCHITECTURAL PRODUCTS IS NOT RESPONSIBLE FOR QUANTITIES ORDERED. RECOMMENDED QUANTITIES MUST BE VERIFIED AND ARE THE RESPONSIBILITY OF THE CUSTOMER. REFER TO THE SMARTci INSTALLATION GUIDE FOR DIRECTIONS AND MORE INFORMATION.
AutoCAD SHX Text
MIN. 22 GAUGE CONTINUOUS GALVANIZED STEEL 6" X 2" ANGLE CORNER 6" X 2" ANGLE CORNER ANGLE CORNER CLOSURE, FASTENED AT EVERY GREENGIRT
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
ACCESSORIES & GEN. NOTES
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
15
Page 15: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
OPTIONAL CAVITY BATT INSULATION (BY OTHERS)
AutoCAD SHX Text
APPROVED 1/4"-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
OVER OPEN FRAMING, FILL ALL INTERIOR SMARTci VOIDS WITH APPROVED EXPANDABLE SEALANT, TYP.
AutoCAD SHX Text
OPTIONAL INTERIOR VAPOR RETARDER (BY OTHERS)
AutoCAD SHX Text
OPEN METAL (OR WOOD) FRAMING (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
WALL SECTION
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
0
Page 16: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
APPROVED "-14 LOW-PROFILE 14"-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
BLOCKING AS REQ'D (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRTS AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
PARAPET FLASHINGS / MEMBRANES (BY OTHERS)
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS HORZ. 14" MIN. CONTINUOUS HORZ. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS HORZ. BEAD BEHIND ALL PARAPET ANGLES, TYP.PARAPET ANGLES, TYP.ANGLES, TYP.
AutoCAD SHX Text
SMARTCI ANGLE
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
PARAPET DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
1
Page 17: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GRADE
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
14" MIN. TWO HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN THE STARTING INSULATION PANEL AT THE FOUNDATIONS
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
FOUNDATION NOTCH DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
2
Page 18: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GRADE
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN THE STARTING INSULATION PANEL AT THE FOUNDATIONS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
14" MIN. TWO HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
FOUNDATION FLUSH DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
3
Page 19: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

15

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
APPROVED "-14 LOW 14"-14 LOW LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
APPROVED "-14 LOW 14"-14 LOW LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
FASTEN OUTSIDE ANGLE @ EVERY GREENGIRT; SHIP LAP MIN. 1" W/MIN. " BEAD OF 14" BEAD OF APPROVED SEALANT AT ALL ANGLE LAPS, TYP.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
INSIDE CORNER DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
4
Page 20: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

15

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN FRAMING; S ATTACHED TO OPEN FRAMING; ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. BEADS 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
FASTEN OUTSIDE ANGLE @ EVERY GREENGIRT; SHIP LAP MIN. 1" W/MIN. " 14" BEAD OF APPROVED SEALANT AT ALL ANGLE LAPS, TYP.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
OUTSIDE CORNER DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
5
Page 21: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
TWO " MIN. CONTINUOUS HORZ. BEADS 14" MIN. CONTINUOUS HORZ. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS HORZ. BEAD BEHIND ALL HEADER ANGLES, TYP.
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE, SPACED AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
@ OPENING HEADERS: APPLY SMARTci TAPE TO INSULATION PANEL, LAP OVER GREENGIRT TO AIR SEAL RIB, BEFORE INSTALLING THE NEXT PANEL ABOVE
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN STARTING INSULATION PANELS
AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
HEADER DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
6
Page 22: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
APPROVED 1/4" #14 LOW PROFILE 1/4" #14 LOW PROFILE " #14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING SMARTci 4" SEALING 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. BEADS 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS VERT. BEAD BEHIND ALL JAMB ANGLES, TYP.
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
JAMB DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
7
Page 23: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
CUSTOM FIELD-CUT SMARTci RIGID SMARTci RIGID INSULATION PANEL, TO FIT BELOW , TO FIT BELOW SILL ANGLE
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS HORZ. BEADS 14" MIN. CONTINUOUS HORZ. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS HORZ. BEAD BEHIND ALL SILL ANGLES, TYP.
AutoCAD SHX Text
SMARTCI TRIM
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SILL DETAIL
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
8
Page 24: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

F2

15

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SHIP LAP 4" SMARTci SEALING TAPE AT ALL SOFFIT EXTERIOR CORNERS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING SMARTci 4" SEALING 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN STARTING INSULATION PANELS
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. HORZ. BEADS OF 14" MIN. HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT OUTSIDE DETAIL-1
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
9
Page 25: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

F2

15

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN GIRTS ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT INSIDE DETAIL-1
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
10
Page 26: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

F2

15

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS BEADS OF 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
SHIP LAP 4" SMARTci SEALING TAPE AT ALL SOFFIT EXTERIOR CORNERS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING SMARTci 4" SEALING 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL (~12" O.C.) BEAD OF SEALANT TO RETAIN STARTING INSULATION PANELS
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT OUTSIDE DETAIL-2
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
11
Page 27: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

F2

15

15

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
OPEN METAL (OR WOOD) STUD FRAMING (BY OTHERS)
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
APPROVED "-14 LOW PROFILE 14"-14 LOW PROFILE LOW PROFILE FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. HORZ. CONTINUOUS 14" MIN. HORZ. CONTINUOUS BEADS OF APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO OPEN S ATTACHED TO OPEN ATTACHED TO OPEN FRAMING; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES
AutoCAD SHX Text
ATTACHED AT EVERY GREENGIRT
AutoCAD SHX Text
AT EACH INSULATION PANEL CORNER, A BEAD OF APPROVED SEALANT MIN. 2" IN EACH DIRECTION.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SOFFIT INSIDE DETAIL-2
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
12
Page 28: METAL ACCESSORIES OPEN - SMARTcI · continuous smartci 4" sealing tape over all greengirt and over all panel joints, typ. 1/2" expandable sealant. recommended: an occasional (~12"

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F2
AutoCAD SHX Text
15
AutoCAD SHX Text
F4
AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F1
AutoCAD SHX Text
15
AutoCAD SHX Text
F1
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F3
AutoCAD SHX Text
15
AutoCAD SHX Text
F3
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
MIN. 22 GAUGE METAL 1 1/2" x 1 1/2" ANGLED RETENTION CLIPS, MAX 24" O.C.
AutoCAD SHX Text
MIN. 22 GAUGE CONTINUOUS GALVANIZED STEEL 1 3/4" X 4 1/4" ANGLE CORNER 1 3/4" X 4 1/4" ANGLE CORNER ANGLE CORNER CLOSURE, FASTENED AT EVERY GREENGIRT
AutoCAD SHX Text
MIN. 22 GAUGE CONTINUOUS GALVANIZED STEEL 6" X 2" ANGLE CORNER 6" X 2" ANGLE CORNER ANGLE CORNER CLOSURE, FASTENED AT EVERY GREENGIRT
AutoCAD SHX Text
NOTE! REQUIRED ACCESSORIES AND METAL FLASHINGS MUST BE USED WITH THIS SYSTEM. THESE COMPONENTS CAN BE MANUFACTURED AND / OR PROVIDED BY ADVANCED ARCHITECTURAL PRODUCTS, OR BY THE CUSTOMER. THEY ARE NOT OPTIONAL, AND ARE NECESSARY FOR THE PROPER INSTALLATION AND FUNCTION OF THE SYSTEM. PLEASE CONTACT AN A2P SALES REPRESENTATIVE WITH ANY QUESTIONS, FOR PRICING INFORMATION, OR TO INQUIRE ABOUT CUSTOM-SIZED METAL FLASHINGS AND ACCESSORIES. GREENGIRTS AND CUSTOM-PROFILED RIGID INSULATION PANELS ARE PROVIDED FOR THIS PROJECT AS A THERMALLY-BROKEN COMPOSITE SUB-FRAMING SYSTEM AND CONTINUOUS INSULATION. THIS SYSTEM DOES NOT INCLUDE MOISTURE DRIVE DESIGN OR VAPOR BARRIER DESIGN AND PLACEMENT. WEATHER PROOFING, RESISTANCE AND / OR WATER TIGHTNESS IS THE SOLE RESPONSIBILITY OF OTHERS. PROPER FLASHINGS & COUNTER FLASHINGS MUST BE INSTALLED BY OTHERS, AND IT IS RECOMMENDED THAT PROVEN CONSTRUCTION BEST PRACTICES BE FOLLOWED AT ALL TIMES. DO NOT INSTALL ANY A2P PRODUCT UNLESS CARE HAS BEEN TAKEN TO REVIEW ALL OF THE DOCUMENTS RELEVANT TO THE PRODUCT INSTALLATION, AND PROPER TRAINING HAS BEEN COMPLETED. ALWAYS DEFAULT TO ARCHITECT'S DETAILS AND DESIGN INTENT! DETAILS ARE PROVIDED FOR INFORMATION ONLY, AS IT PERTAINS TO INSTALLING DETAILS ARE PROVIDED FOR INFORMATION ONLY, AS IT PERTAINS TO INSTALLING GREENGIRT. SPECIFIC PROJECT ENGINEERING (BY OTHERS) WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. ALWAYS REVIEW LOADING REQUIREMENTS WITH THE PROJECT ENGINEER, AND USE APPROPRIATE FASTENERS AND SPACING. USE PLASTIC HORSESHOE SHIMS WHERE REQUIRED TO ACHIEVE ± 1/16" DEFLECTION; MAX. SHIM DEPTH IS 1/4". USE SPRAY FOAM AT ALL VOIDS TO ENSURE CONTINUOUS INSULATION. DO NOT USE IMPACT HAMMERS, IMPACT DRILLS OR SIMILAR TOOLS TO INSTALL GREENGIRT! ADVANCED ARCHITECTURAL PRODUCTS MAKES NO CLAIMS OR GUARANTEES ABOUT ANY ITEMS MANUFACTURED BY OTHERS. ADVANCED ARCHITECTURAL PRODUCTS IS NOT RESPONSIBLE FOR QUANTITIES ORDERED. RECOMMENDED QUANTITIES MUST BE VERIFIED AND ARE THE RESPONSIBILITY OF THE CUSTOMER. REFER TO THE SMARTci INSTALLATION GUIDE FOR DIRECTIONS AND MORE INFORMATION.
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: -
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
ACCESSORIES & GEN. NOTES
AutoCAD SHX Text
OPEN FRAMING
AutoCAD SHX Text
15