11
: ADVANCED ARCHITECTURAL PRODUCTS www.SMARTciSystems.com 1 (269) 355-1818 SMARTci SMARTER BY DESIGN. PROVEN BY PERFORMANCE. SMARTci+ System

SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
OPTIONAL CAVITY BATT INSULATION (BY OTHERS)
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON METAL (OR WOOD) FRAMING / MASONRY WALL ASSEMBLY (BY OTHERS)
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
OPTIONAL INTERIOR VAPOR RETARDER (BY OTHERS)
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD DEAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
WALL SECTION
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
0
Page 2: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

F1

13

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRTS AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
TWO " MIN. HORZ. BEADS OF 14" MIN. HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
COPING FLASHING & PARAPET CAP TRIM ATTACHED TO BLOCKING WITH CORROSION RESISTANT METAL FASTENER (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION PANEL
AutoCAD SHX Text
MEMBRANE FLASHING (BY OTHERS)
AutoCAD SHX Text
BLOCKING AS REQ'D (BY OTHERS)
AutoCAD SHX Text
HORIZONTAL TAPE @ EXPANDABLE SEALANT
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD DEAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
PARAPET DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
1
Page 3: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
MEMBRANE FLASHING (BY OTHERS)
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
TYP.: ADD A BEAD OF SEALANT BEHIND, ON GREENGIRT, AND TAPE OVER ALL FLASHINGS ATTACHED TO SMARTci (BY OTHERS)
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL OR CONTINUOUS BEAD OF SEALANT TO RETAIN STARTER PANELS, TYP.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
14" MIN. TWO HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
FLASHING (BY OTHERS)
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD DEAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
FOUNDATION NOTCH DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
2
Page 4: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL OR CONTINUOUS BEAD OF SEALANT TO RETAIN STARTER PANELS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
14" MIN. TWO HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
CONCRETE FOOTING
AutoCAD SHX Text
MEMBRANE FLASHING (BY OTHERS)
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD DEAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
RECOMMENDED:METAL RETENTION CLIP ATTACHED TO EACH GREENGIRT AND OVERLAPPING EACH INSULATION PANEL
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
FOUNDATION FLUSH DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
3
Page 5: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

13

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
RECOMMENDED:CONTINUOUS METAL CLOSURE, FASTEN TO GREENGIRT @ MAX. 16" O.C, SHIP LAP MIN. 1" W/MIN. 1/4" BEAD OF APPROVED SEALANT AT ALL ANGLE LAPS, TYP.
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE FASTENERS, MAX. 16" O.C.; LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
INSIDE CORNER DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
4
Page 6: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

13

F2

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT BEHIND AND BELOW [MARRIAGE BEADS] INSULATION PANELS
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
RECOMMENDED:CONTINUOUS METAL CLOSURE, FASTEN TO GREENGIRT @ MAX. 16" O.C, SHIP LAP MIN. 1" W/MIN. 1/4" BEAD OF APPROVED SEALANT AT ALL ANGLE LAPS, TYP.
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION CORROSION CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD LOAD DEAD LOAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
OUTSIDE CORNER DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
5
Page 7: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
TWO " MIN. HORZ. BEADS OF 14" MIN. HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANEL, TYP.
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD DEAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL OR CONTINUOUS BEAD OF SEALANT TO RETAIN STARTER PANELS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
STRUCTURAL STEEL LINTEL (BY OTHERS) TO BEAR ON ADJACENT JAMB BRICKS
AutoCAD SHX Text
@ OPENING HEADERS: APPLY SMARTci TAPE TO INSULATION PANEL, LAP OVER GREENGIRT TO AIR SEAL RIB, BEFORE INSTALLING THE NEXT PANEL ABOVE
AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
HEADER DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
6
Page 8: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

13

F3

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
TWO " MIN. CONTINUOUS VERT. BEADS 14" MIN. CONTINUOUS VERT. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS VERT. BEAD BEHIND ALL JAMB ANGLES, TYP.
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING SMARTci 4" SEALING 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
LAP 4" SMARTCI SEALING TAPE OVER ALL OPENING ANGLES TO SUBSTRATE TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD LOAD NOT SUPPORTED BY DEAD LOAD NOT SUPPORTED BY DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
BRICK VENEER CLOSURE FLASHING (BY OTHERS)
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
JAMB DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
7
Page 9: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

F3

13

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
TWO " MIN. CONTINUOUS HORZ. BEADS 14" MIN. CONTINUOUS HORZ. BEADS OF APPROVED SEALANT ON AND ONE CONTINUOUS HORZ. BEAD BEHIND ALL SILL ANGLES, TYP.
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
CUSTOM FIELD-CUT SMARTci SMARTci RIGID INSULATION PANEL, TO , TO FIT BELOW SILL ANGLE
AutoCAD SHX Text
SILL FLASHING & SILL FLASHING TRIM ATTACHED TO METAL WITH CORROSION RESISTANT METAL FASTENER (BY OTHERS)
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
LAP 4" SMARTCI SEALING TAPE OVER ALL OPENING ANGLES TO SUBSTRATE TYP.
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD DEAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
LAP 4" SMARTci SEALING TAPE MIN. 1 " INTO OPENINGS. TYP.12" INTO OPENINGS. TYP.
AutoCAD SHX Text
1/2" EXPANDABLE SEALANT
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
SILL DETAIL
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
8
Page 10: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
@ SHEATHED WALLS: APPROVED 1/4-14 LOW-PROFILE LOW-PROFILE FASTENERS, MAX. 16" O.C.; MUST FASTEN INTO STUDS, TYP. (BY OTHERS) @ MASONRY WALLS: APPROVED 1/4" LOW-PROFILE THREADED AND COATED MASONRY FASTENERS, MAX. 16" O.C., TYP. (BY OTHERS)
AutoCAD SHX Text
RECOMMENDED: AN OCCASIONAL OR CONTINUOUS BEAD OF SEALANT TO RETAIN STARTER PANELS, TYP.
AutoCAD SHX Text
CONTINUOUS SMARTci 4" SEALING TAPE OVER ALL GREENGIRT AND OVER ALL PANEL JOINTS, TYP.
AutoCAD SHX Text
14" MIN. TWO HORZ. BEADS OF CONTINUOUS APPROVED SEALANT BEHIND INSULATION PANELS, TYP.
AutoCAD SHX Text
SMARTci CUSTOM-PROFILED RIGID INSULATION, WITH SPLINES AT ALL VERT. JOINTS
AutoCAD SHX Text
SHEATHING ON CFMF / WOOD FRAMING (BY OTHERS)
AutoCAD SHX Text
SHEET METAL FLASHING, TRIM AND ROOF (BY OTHERS)
AutoCAD SHX Text
AIR SPACE
AutoCAD SHX Text
BRICK VENEER SYSTEM ATTACHED TO GREENGIRTS WITH CORROSION RESISTANT CORROSION RESISTANT CORROSION RESISTANT FASTENER AND APPROVED BRICK TIE; DEAD DEAD DEAD LOAD NOT SUPPORTED BY GREENGIRTS; SPACING AS REQ'D PER LOADING CONDITIONS & CODE (BY OTHERS)
AutoCAD SHX Text
STRUCTURAL STEEL LINTEL (BY OTHERS) TO BEAR ON ADJACENT JAMB BRICKS
AutoCAD SHX Text
MASONRY WALL (BY OTHERS)
AutoCAD SHX Text
GREENGIRTS ATTACHED TO SUBSTRATE; SPACING AS REQUIRED PER LOADING CONDITIONS AND CODES; MAX. 1/4" SHIMS WHERE REQ'D
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
BASE AT ROOF
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
11
Page 11: SMARTci · 2018. 4. 5. · sheathing on metal (or wood) framing / masonry wall assembly (by others) continuous smartci 4" sealing tape over all greengirt and over all panel joints,

:

ADVANCED

ARCHITECTURAL

PRODUCTS

www.SMARTciSystems.com 1 (269) 355-1818

SMARTci

SMARTER BY DESIGN. PROVEN BY PERFORMANCE.

SMARTci+ System

AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F2
AutoCAD SHX Text
13
AutoCAD SHX Text
F2
AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F1
AutoCAD SHX Text
13
AutoCAD SHX Text
F1
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text
GIRTH
AutoCAD SHX Text
F3
AutoCAD SHX Text
13
AutoCAD SHX Text
F3
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
MIN. 22 GAUGE METAL 1 1/2" x 1 1/2" ANGLED RETENTION CLIPS, MAX 24" O.C.
AutoCAD SHX Text
MIN. 22 GAUGE CONTINUOUS GALVANIZED STEEL 1 3/4" X 4 1/4" ANGLE CORNER 1 3/4" X 4 1/4" ANGLE CORNER ANGLE CORNER CLOSURE, FASTENED AT EVERY GREENGIRT
AutoCAD SHX Text
NOTE! REQUIRED ACCESSORIES AND METAL FLASHINGS MUST BE USED WITH THIS SYSTEM. THESE COMPONENTS CAN BE MANUFACTURED AND / OR PROVIDED BY ADVANCED ARCHITECTURAL PRODUCTS, OR BY THE CUSTOMER. THEY ARE NOT OPTIONAL, AND ARE NECESSARY FOR THE PROPER INSTALLATION AND FUNCTION OF THE SYSTEM. PLEASE CONTACT AN A2P SALES REPRESENTATIVE WITH ANY QUESTIONS, FOR PRICING INFORMATION, OR TO INQUIRE ABOUT CUSTOM-SIZED METAL FLASHINGS AND ACCESSORIES. GREENGIRTS AND CUSTOM-PROFILED RIGID INSULATION PANELS ARE PROVIDED FOR THIS PROJECT AS A THERMALLY-BROKEN COMPOSITE SUB-FRAMING SYSTEM AND CONTINUOUS INSULATION. THIS SYSTEM DOES NOT INCLUDE MOISTURE DRIVE DESIGN OR VAPOR BARRIER DESIGN AND PLACEMENT. WEATHER PROOFING, RESISTANCE AND / OR WATER TIGHTNESS IS THE SOLE RESPONSIBILITY OF OTHERS. PROPER FLASHINGS & COUNTER FLASHINGS MUST BE INSTALLED BY OTHERS, AND IT IS RECOMMENDED THAT PROVEN CONSTRUCTION BEST PRACTICES BE FOLLOWED AT ALL TIMES. DO NOT INSTALL ANY A2P PRODUCT UNLESS CARE HAS BEEN TAKEN TO REVIEW ALL OF THE DOCUMENTS RELEVANT TO THE PRODUCT INSTALLATION, AND PROPER TRAINING HAS BEEN COMPLETED. ALWAYS DEFAULT TO ARCHITECT'S DETAILS AND DESIGN INTENT! DETAILS ARE PROVIDED FOR INFORMATION ONLY, AS IT PERTAINS TO INSTALLING DETAILS ARE PROVIDED FOR INFORMATION ONLY, AS IT PERTAINS TO INSTALLING GREENGIRT. SPECIFIC PROJECT ENGINEERING (BY OTHERS) WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. ALWAYS REVIEW LOADING REQUIREMENTS WITH THE PROJECT ENGINEER, AND USE APPROPRIATE FASTENERS AND SPACING. USE PLASTIC HORSESHOE SHIMS WHERE REQUIRED TO ACHIEVE ± 1/16" DEFLECTION; MAX. SHIM DEPTH IS 1/4". USE SPRAY FOAM AT ALL VOIDS TO ENSURE CONTINUOUS INSULATION. DO NOT USE IMPACT HAMMERS, IMPACT DRILLS OR SIMILAR TOOLS TO INSTALL GREENGIRT! ADVANCED ARCHITECTURAL PRODUCTS MAKES NO CLAIMS OR GUARANTEES ABOUT ANY ITEMS MANUFACTURED BY OTHERS. ADVANCED ARCHITECTURAL PRODUCTS IS NOT RESPONSIBLE FOR QUANTITIES ORDERED. RECOMMENDED QUANTITIES MUST BE VERIFIED AND ARE THE RESPONSIBILITY OF THE CUSTOMER. REFER TO THE SMARTci INSTALLATION GUIDE FOR DIRECTIONS AND MORE INFORMATION.
AutoCAD SHX Text
MIN. 22 GAUGE CONTINUOUS GALVANIZED STEEL 6" X 2" ANGLE CORNER 6" X 2" ANGLE CORNER ANGLE CORNER CLOSURE, FASTENED AT EVERY GREENGIRT
AutoCAD SHX Text
SUBSTRATE:
AutoCAD SHX Text
TM
AutoCAD SHX Text
DETAILS ARE PROVIDED FOR INFORMATION ONLY, AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. SPECIFIC PROJECT ENGINEERING BY BY OTHERS WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. WILL ADDRESS ATTACHMENT SPACING, ORIENTATION AND LOADING. REFER TO A2P DESIGN GUIDE FOR SEALANT REQUIREMENT. CONTACT ADVANCED ARCHITECTURAL PRODUCTS FOR FURTHER DETAILS, AND TO INQUIRE ABOUT UPDATES AND REVISIONS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CLADDING: BRICK
AutoCAD SHX Text
SIMPLE-Z SIZE: 200
AutoCAD SHX Text
DATE: 04-05-2018
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
GIRT ORIENTATION: HORIZONTAL
AutoCAD SHX Text
SMARTci RIGID INSULATION PANELRIGID INSULATION PANEL
AutoCAD SHX Text
ACCESSORIES & GEN. NOTES
AutoCAD SHX Text
SHEATHING / MASONRY
AutoCAD SHX Text
13