Mapping nanoscale thermal transport in liquid environment - immersion scanning
thermal microscopy
Peter D Tovee and Oleg V Kolosov1
Physics Department, Lancaster University, Lancaster, LA1 3BE, UK.
1Author to whom any correspondence should be addressed
E-mail: [email protected]
Abstract.
Nanoscale heat transport is of increasing importance as it often defines performance
of modern processors and thermoelectric nanomaterials, and affects functioning of
chemical and biosensors. Scanning Thermal Microscopy (SThM) is the leading tool
for nanoscale mapping of thermal properties, but it is often negatively affected by
unstable tip-surface thermal contacts. While operating SThM in liquid environment
may allow unimpeded thermal contact and open new application areas, it was so far
regarded impossible due to increased heat dissipation into liquid, and perceived non-
local thermal interaction between the probe and the sample. Nevertheless, in this
paper we show for the first time that such liquid immersion SThM (iSThM) is fully
feasible and has sufficient thermal contrast to detect thermal conductivity variations
in the few tens of nm thick graphite nanoflake and metal-polymer nanostructured
interconnects. Its spatial resolution was on the order of 50 nm, equal to the resolution
of the same probe in the standard air environment. These results confirm localized
thermal sensing in iSThM and, coupled with absence of tip snap-in due to
elimination of capillary forces, suggest the possibility for true non-contact nanoscale
thermal mapping in liquids, including thermal phenomena in energy storage devices,
catalysts and biosystems.
PACS:
1. Introduction.
Since its invention, scanning probe microscopy (SPM) [1, 2] became an indispensable tool of
modern nanotechnology. One of major advantages of SPM is its ability to sense diverse
physical and chemical properties of nanostructures with nanometer resolution [3-5] including
operation in various environments [6]. In particular, nanoscale temperature measurements [7],
heat generation and nanoscale heat propagation are of increasing importance due to
continuous decrease of size of semiconductor devices with concurrent increase of processing
power [8-10]. While active Scanning Thermal Microscopy (SThM) [11-22] that uses self-
heated thermal sensors in contact with the studied sample allows nanoscale mapping of
thermal properties, a weak thermal coupling between sensor and the sample is one of major
SThM problems [16]. Furthermore, this coupling fluctuates while scanning and is also
affected by sample geometry, overall significantly reducing SThM performance in nanoscale
thermal measurements.
It would be very tempting to use liquid immersion in SThM to improve both the thermal
contact between the probe tip and the sample as well as contact uniformity. The approach
would be somewhat similar to one used in ultrasonic imaging where dedicated gel is used to
achieve better acoustic coupling [23] or optical microscopy where immersion reduces light
reflection, refraction and scattering at the interfaces [24]. While the role of liquid film
between the SThM tip apex is known to be essential [16, 17, 20, 21] up to now there were no
reports on heated nanoscale resolution SThM imaging while probe fully immersed in the
liquid. So far SThM operation both in air and vacuum was demonstrated, with vacuum
helping to eliminate heat dissipation through air [14, 19, 25]. The only reported so far in-
liquid nanoscale thermal measurements used passive fluorescence thermometry [26], that
while having potential for sub-micrometer spatial resolution [27] is not capable of
measurements of local thermal transport or thermal conductivities as it relies on the externally
created heat flux. If feasible, SThM liquid immersion would improve and stabilize thermal
contact between the tip and the surface, compared to in-air or vacuum environment. Also, due
to efficient heat transfer through liquid, it might be possible to perform truly non-contact
scanning with the tip-surface separated by few nm gap, while retaining both nanoscale
resolution and thermal sensitivity. Such in-liquid SThM, would be of extreme interest for
biotechnology, where it will allow handling of delicate biological samples [28] and in
exploration of energy generation and dissipation in rechargeable batteries, fuel cells and
liquid phase catalysts.
Unfortunately, until now fully immersed operation of SThM has been considered all but
impossible due to the potentially overwhelming direct heat dissipation from the heated sensor
into the surrounding liquid, that was perceived to result in the non-local thermal sensing and
degradation of lateral resolution [16]. To our knowledge, there is so far no publication
reporting such approach and measurements. Notwithstanding this rationale, in this paper we
show that such immersion SThM, or iSThM, can be successfully realized using certain design
of a SThM probe that is fully immersed in a liquid [29]. We found, surprisingly, that iSThM
performance would not be qualitatively different from the in-air or in-vacuum environment
operation [19, 20, 25]. We then apply iSThM to explore the heat transport in polymer-metal
ultra large scale integration interconnects [30], and in few tens of nm thick graphite nanoflake
[31] on Si substrate. In these nanostructures we observe 50 nm lateral resolution to local
thermal conductance that confirmed a local nature of iSThM thermal contrast, with
experimental finding supported by the numerical simulations that allowed to understand the
underlying nature and imaging mechanisms of a new approach.
2. Methods and materials
2.1 Finite elements modeling of SThM probes in air and liquid environment.
In order to explore the feasibility of iSThM and to find optimal experimental approach, we
first simulated behavior of various SThM probes in air and liquid environments. The
simulations were based on commercial finite elements (FE) (COMSOL Multiphysics)
approach in the 3D probe geometry. We used COMSOL AC/DC module for modeling the
current flow, Joule heating of the probe and a probe resistance that reflected probe
temperature, as well as thermal module for modeling of heat transport [29]. Given that mean-
free-path length of heat carriers (phonons in dielectrics and electrons in metals) in relevant
materials in the model were generally on the order of 10-25 nm, and the minimal
characteristic dimensions of the probe geometrical elements were 50 nm or larger, a diffusive
approximation and Fourier heat transport equations were deemed to be adequate [19].
Figure 1. FE modeling of spatial temperature distribution for
iSThM for (a) DS and (b) SP probe; the heating power was
normalized to produce the same maximum T of the probe,
dodecane immersion was used. (c, d) Comparison of high
temperature field in the vicinity of tip apex for in-air (SThM)
and in-liquid iSThM in contact with Si sample; same heating
power was used. Dotted lines in the images indicate the
sample surface.
At first glance, the direct heat dissipation from SThM probe to the surrounding liquid might
result in the complete loss of sensitivity to local thermal properties of the sample and lead to
non-localized thermal response [16, 20]. In fact, FE modeling of a widely used doped Si
probe (DS) [13, 29] (AN-200, TA Instruments) in dodecane (this liquid was selected for its
low-volatility, moderate thermal conductivity and a non-corrosiveness) supported such
general belief showing that the heat plum is concentrated near the heater and far from the
sample (Figure 1(a)). Such heat distribution would indeed significantly decrease sample
related thermal signal and spatial resolution. Surprisingly, at the same time, FE analysis of
another widely used design of Si3N4 probe with Pd resistive element at the end of the probe
tip (SP probe) (Kelvin Nanotechnologies) [29, 32] showed a distinctive narrow heat plum
concentrated near the end of the probe (Figure 1(b). The absolute value of the SP probe
temperature with respect to the environment was only slightly lower in liquid - 35 degrees vs
54 degrees in air, corresponding to only 35% loss of thermal signal (see temperature scale in
Figure 1 (c,d). More significantly, a temperature field near the probe apex shows almost
identical pattern of the spatial distribution of temperature for SP probe in- air (Figure 1(c) and
in liquid (Figure 1(d). These finding strongly suggested that SP should be a probe of choice
for iSThM experimental trials.
(c) (d)
(b)
(a)
293 K
343 K
5 m
5 m
200 nm 200 nm
doped Si (DS) probe in-liquid
SP probe in-air
293 K
343 K
Si3N4/Pd (SP) probe in-liquid
SP probe in-liquid
2.2. Experimental setup of SThM and thermal measurements.
Our iSThM experiments used a general purpose SPM (Bruker Multi-Mode, Nanoscope III)
with “half-moon” SThM probes holder (Anasys Instruments) that was modified for using
thermal probe in liquids as shown in Figure 2. A special PTFE cup was used to contain the
liquid as well as to keep the sample, thermal cantilevers and connecting leads immersed in
liquid. A glass window was used to create a flat refraction interface for SPM laser beam that
monitors cantilever deflection. A nitrile rubber thin sheet was used underneath the liquid
holder to protect the scanner from accidental liquid spilling.
Figure 2. Probe and sample arrangement in iSThM.
The SP thermal probe was calibrated on a Peltier variable temperature plate (Echo Therm
IC20, Torrey Pines Scientific) at temperatures ranging from room temperature to 80C by
measuring probe electrical resistance as a function of the applied voltage and ambient
temperature. Two types of resistance measurements were used – in the first the probe formed
a part of a DC voltage divider in series with the fixed resistor, this method was found to be
highly accurate but slow and used predominantly during the calibration. The second method
combined low AC voltage signal at 91 kHz frequency that was used for resistance
measurements, and higher DC offset providing probe self-heating. In this method the probe
formed a part of a balanced Maxwell electric bridge, with its output measured via the lock-in
amplifier (SRS-830, Stanford Research Systems). In second mode the resulting signal rapidly
followed the resistance changes but had less absolute accuracy, this mode was mainly used
for real-time SThM imaging. The AC and DC voltage excitation for all measurements was
provided by the precision function generator (Model 3390, Keithley Instruments). Both
approaches indicated a linear dependence of the probe resistance on its temperature that was
expected as the metallic resistive sensing element was used. As the tip is brought in contact
with the surface during SThM imaging, some heat starts to flow into the sample cooling the
tip and, consequently, changing resistance of the sensor. Using a Maxwell bridge and
combined AC-DC excitation [29] the well-defined power can be applied to the sensor
generating Joule heat, with the tip temperature measured simultaneously. As the tip is
scanned across the sample, monitoring these values allows to create a thermal image with the
lower temperature of the probe corresponding to the higher local heat flux into the sample,
therefore allowing direct evaluation of its local thermal conductivity [16, 19, 33].
2.3 Sample preparation.
Two samples used in this study were selected for two interlinked purposes. First we targeted
to prove experimentally a feasibility of iSThM, its sensitivity to local thermal conductivity,
and thermal spatial resolution while imaging diverse materials, such as metals, polymers, and
semiconductors. Secondly, if iSThM approach is successful, we were interested in
experimental exploration of differences of nanoscale thermal transport in air and in the liquid
environment when nature of thermal contact between the material and surrounding liquid
immersion may modify such transport. First sample was a metal-polymer nanostructure,
where Al damascene embedded layer [30] was enclosed in benzocyclobutene (BCB) low-k
dielectric, this sample was used to represent morphology and materials of the ultra large scale
integration interconnects (ULSI). Heat transport in ULSI nanostructures is of significant
concern as metallization tracks in a real device carry significant amount of current and their
overheating would increase the electro-migration and adversely affect the stability of the
semiconductor device [30]. High resolution lithography used in the sample preparation
provided a well-defined boundary between metal and BCB, while the chemo-mechanical
polishing provided relatively flat surfaces with moderate topographical contrast. The second
sample was in-house exfoliated a few layer graphene/graphite nanoflakes with thicknesses up
to few tens of nm deposited on Si wafer with 300 nm thermal oxide layer on the top. The
ULSI interconnects were cleaned by 10 min sonication consecutively in acetone, ethanol, and
DI water, with final plasma cleaning performed in O2/Ar plasma for 5 minutes. Such stringent
procedure removes any residual organic contaminants on the surface. The Si wafer prior to
the deposition of nanoflakes was cleaned using the same procedure, and nanoflake was then
mechanically exfoliated from Kish graphite lumps using pressure sensitive tape, with the final
exfoliation step performed by cross-linked polymer gel (Gel-Pak, USA) that helped to
minimize tape residue transfer [19].
3. Results and discussion
3.1 Feasibility of iSThM: sensing thermal conductivity with nanoscale resolution and local
nature of iSThM response.
The feasibility of liquid environment iSThM operation was first tested on ULSI interconnect
structures described above. The measurements were performed by the probe first operated in-
air and then in-the-liquid dodecane environment, allowing making relevant and definitive
comparisons as exactly the same probe was used. Topography images in both environments
shown in Figure 3(a,b) reveal similar features - a protruding central Al metallization lead with
few voids (that are usually located at Al grain boundaries [34]) embedded in the BCB
polymer matrix. The in-air SThM image in Figure 3(c) obtained at a constant Joule heating
power applied to the sensor, clearly shows that the Al interconnects produce better heat
dissipation (darker image contrast reflects the lower temperature of the probe due to increased
heat flow from the probe). This is consistent with the higher thermal conductivity for Al, kAl =
200 Wm-1
K-1
compared to thermal conductivity of BCB, kBCB = 29 Wm-1
K-1
. The absolute
topographical height (~ 80 nm) seemed to provide no direct influence for in-air thermal
image, at the same time the “rim” of Al lead looked brighter. One can expect certain increase
of heat transport at the Al edge due to increased contact area with the side of SThM tip, and
hence darker SThM contrast, but this was not observed. Most likely the nanoscale roughness
of the side edge created a barrier to the heat transport resulting in it imaged as “hotter” -
brighter areas in in-air SThM images.
iSThM thermal image in Figure 3(d) shows qualitatively same features – darker Al
metallization layer with better heat dissipation surrounded by the brighter, lower heat
conductance BCB matrix. As for in-air SThM thermal image, the absolute topographical
height of the Al layer (~ 80 nm) provided no direct influence on the iSThM thermal image,
confirming the local nature of the probing. The lateral resolution of iSThM was similar to the
resolution of in-air SThM, as seen from the comparison of line profiles given in Figure 3(e).
This was further supported by FE simulation of the same profiles in Figure 3(d) where the
thermal signal across the interface between Al and BCB polymer shows excellent qualitative
correspondence with experimentally obtained SThM and iSThM profiles. In both modes, the
thermal signal on the Al – BCB polymer boundary shows appreciable change over
approximately 50 nm distance, in good correlation with the experimental results. The
experimentally measured signal-to-noise ratio of iSThM thermal image was lower compared
to in-air SThM, that was most likely linked with the additional heat dissipation into the liquid
adding to the common for SThM and iSThM modes heat dissipation to the cantilever base.
Nevertheless, the thermal signal was fully sufficient for nanoscale mapping of thermal
conductivity in ULSI nanostructure in iSThM. While more definitive comparison of the
lateral resolution in iSThM and SThM is given later in the paper using a well-defined edge of
graphite nanoflake, data in Figure 3 clearly indicate that iSThM operating in liquid
environment is feasible and capable of nanoscale mapping of local thermal conductivities.
The interesting observation was that in contrast to in-air SThM, the voids in Al (observed in
both topographical images) did not produce significant increase in thermal response in iSThM
suggesting that the immersion liquid secured direct thermal contact of the probe and the
studied material. Also a darker edge around Al lead that indicated higher heat transport to the
side of the lead was observed without lighter “rim” in iSThM. These observations suggest
that iSThM has potential of eliminating detrimental effects of surface roughness, and can
reflect more directly the intrinsic heat transport in nanostructures.
Figure 3. In-air SThM and iSThM images of Al - BCB
polymer interconnects sample. (a) In-air SThM topography
(height) and (c) thermal images. (b) In-dodecane iSThM
topography and (d) thermal images. Thermal images are
obtained in a constant power mode, dark contrast
corresponds to lower probe temperature due to higher heat
dissipation to the sample that reflects higher local thermal
conductivity. (e) Comparison of experimentally measured
line profiles of thermal signal for SThM and iSThM across
Al-BCB boundary. (d) Results of the FE simulation
comparing line profiles in SThM and iSThM across Al-
BCB boundary.
3.2 iSThM mapping of thermal transport in thermally anisotropic graphite nanoflake.
The iSThM was then applied to investigate thermal conductivity of graphite nanoflakes of
approximately 40 nm thickness on Si substrate (Figure 4). Thermal properties of a few layer
graphene and graphite exhibit extremely anisotropic thermal conductivity that depends on the
direction of the heat flux. Ratio of thermal conductivity parallel and perpendicular to
graphene planes [35] can reach three orders of magnitude (k║-Gr-plane = 2000 Wm-1
K-1
k-Gr-plane
= 2 Wm-1
K-1
) with thermal conductivity in graphene plane exceeding one of Si (kSi = 130
Wm-1
K-1
), whereas conductivity normal to graphene planes being two orders of magnitude
lower that thermal conductivity of Si. Such aspects may play some role in the heat dissipation
in rechargeable batteries, supercapacitors and fuel cells where graphene and graphite is used
in liquid environment [36] with iSThM offering a feasible approach for such studies.
Z: 80 nm
voids voids
Z: 80 nm (a) (b)
Al lead
(e) (f)
BCB Al Al
BCB
Thermal images in Figure 4(c,d) and corresponding line profiles (Figure 4(e,f) show that for
in-air SThM the heat transport is slightly increased in the area of the flake, and the side of the
flake, with clear decrease of heat transport at the flake “rim” (tip position iii, Figure 4(g,h). At
the same time, iSThM thermal image seem to be less affected by the “rim” contrast,
presumably, due to better thermal link between the tip and the sample that is liquid mediated
and less affected by the local surface corrugations. Moreover, the heat transport in the area of
the flake (area iv, as illustrated in the Figure 5(g,h) is slightly below one of Si. That can be
linked with the fact that in-liquid a higher proportion of the heat flux is normal to graphene
layers along the direction of the lower thermal conductivity (k-Gr-plane = 2 Wm-1
K-1
compared
to kSi= 130 Wm-1
K-1
) [37] or with different interfacial Kapitza resistance [38]. The side
surface of the flake provides a better heat dissipation (tip position ii) for both in-air and
iSThM due to high in-plane conductivity of graphene layers (k║-Gr-plane = 2000 Wm-1
K-1
). The
FE simulation of the profile across nanoflake-substrate boundary in Figure 4(i) show slightly
increased heat transport for in-air SThM in the flake area compared to Si substrate, whereas
heat transport for iSThM being reduced in the flake area. The sign of the heat dissipation
difference matches well with the one experimentally observed in Figure 4(e,f). Moreover, the
simulation shows that the spatial variation of the heat dissipation due to presence of the flake
“rim” are reduced in iSThM in good correspondence with experimental data.
Finally, it is to be noted that the full width of half maximum (FWHM) of the flake edge for
iSThM was 56 nm compared with 78 nm for in-air SThM obtained with the same probe
(Figure 4(e,f), confirming the local nature of iSThM thermal response and indicating at least
similar lateral resolution for comparable probes and the samples.
Figure 4. SThM and iSThM nanoscale mapping of thermal
conductivity in graphite nanoflakes. (a) In-air topography and (c)
corresponding thermal image of 40 5 nm thick nanoflake. iSThM
(b) topography and (d) thermal image of a similar flake with 45
5 nm thickness. (g, h) Schematic illustration of different regions in
the images with SthM tip positioned on: i - the substrate, ii –
touching the edge of the flake (thermal contact area increased), iii
– on the “rim” of the flake (contact area decreased), iv - on the top
of the flake. (i) Simulated SThM and iSThM profiles across the
edge of graphite nanoflake.
“rim”, iii
flake edge, ii flake edge, ii
edge width
edge width
z: 45 nm
z:
40 nm
iv i ii
iii
ii
iii iv
substrate
flake
flake
substrate
(a) (b)
(e) (f)
i
iv
(g) (h)
flake edge
“rim”
substrate flake
(i)
3.3 Force contact phenomena in iSThM.
As we observed above, iSthM provides efficient through-the-liquid thermal coupling of the
probe and the sample that eliminates some effects of the surface roughness and voids, e.g. in
ULSI in Figure 2. In principle, that would allow the true non-contact thermal imaging with
the tip hovering at few nm above the studied surface, and enable study of delicate samples
such as biological materials, porous and suspended nanostructures. We have performed FE
simulations that indicated that 50 nm wide tip “hovering” above sample surface at 25 nm
distance would retain 80% of the iSThM in-contact thermal signal, whereas in-air SThM will
retain less than half of such signal.
In order to analyze the non-contact performance of iSThM, we captured simultaneously
thermal signal and mechanical deflection of SThM sensor (proportional to force between the
sample and SThM tip) as the tip approached the sample (Figure 5) similar for in-air
measurements in [20]. In either environment as the tip approaches the surface, the thermal
signal notably decreases, as the heat conducted to the sample via either air [20] or liquid
media cools the probe. For in-air SThM (Figure 5(a,b) there is a well-defined “snap-in” of the
tip towards the surface that is linked with the well-documented formation of meniscus [20,
37] that also leads to the step-wise increase of the pull-in force helping to establish the solid-
solid contact. Such behavior is typical for the relatively compliant cantilever with the sharp
tips like the one used in our study. Once the capillary meniscus and solid-solid contact is fully
established, the thermal signal remains mainly constant even as the contact force increases.
When the sample is retracted, the combined adhesive and meniscus forces lead to even
stronger “snap-off” that results in the jump-off of the cantilever and similar changes in the
thermal response.
In the liquid environment of iSThM the situation was quite different – no clear “snap-in” or
“snap-out” force jumps were observed (Figure 5(c) as it would be expected due to the absence
of capillary forces [39]. Also, no jump of heat dissipation (Figure 5(d) on the solid-solid
contact was observed as it would be for in-air or in-vacuum environments [25]. The absence
of “thermal” jump in combination with the spatial resolution demonstrated in Figures 3(e) and
4(f) suggest that iSThM sensing of local thermal conductivity of the sample is almost fully
liquid mediated. The observed absence of the capillary “snap-in” and “snap-out” in iSThM
coupled with demonstrated in this paper similar to in-air SThM 50 nm lateral resolution to
thermal properties, would make it possible to realize true non-contact nanoscale thermal
imaging by “hovering” iSThM tip in the few to 10 nm above the sample, maintaining the
distance via e.g. well-known shear force feedback [40] that would be easily realized due to
non-zero viscosity of coupling liquid.
Figure 5. Experimental approach-retract curves for SThM
and iSThM probe and Si sample. (a) Force and (b) in-air
SThM thermal signal compared with (c) force and (d) in-
dodecane iSThM thermal signal; approach-retract rate of
0.01 Hz was used.
4. Conclusions
This study demonstrates for the first time that active heating nanoscale SThM thermal
probing in a fully immersed liquid environment (iSThM) is feasible. The iSThM was shown
to be sensitive to the local thermal conductivity of materials ranging from polymers (BCB)
and semiconductors (Si) to metals (Al) and graphite nanoflakes. The effective lateral
resolution on the order of 50 nm was demonstrated using a widely used microfabricated
resistive probe design operating in iSThM mode, and shown to be very similar to the lateral
resolution of the same probe operated in air. Using FE modeling we found that the probe
design may play crucial role for iSThM performance, suggesting that dedicated optimization
of probe for iSThM, e.g. changing the geometry of the heater and the probe apex, can
significantly improve iSThM resolution and performance. The iSThM thermal response was
shown to be in good qualitative agreement with numerical simulations, that supported
experimentally observed iSThM spatial resolution and sensitivity. We confirmed that the heat
flux between the probe and the sample that defines the nanoscale spatial resolution of iSThM
is predominantly conducted through liquid rather solid-solid contact, that may help to
eliminate one of major uncertainties in the nanoscale mapping of heat transport via active
SThM – instability of tip-surface thermal contact. Moreover, such liquid mediated iSThM
should make it possible to realize true non-contact nanoscale thermal imaging by “hovering”
iSThM tip in the vicinity of the sample. We believe that iSThM can open new possibilities for
exploration of heat generated in biological systems [41, 42], and help to investigate nanoscale
thermal phenomena in power batteries, fuel cells, and nanoscale catalysts.
Acknowledgment
Authors acknowledge input of Manuel Pumarol for advice, scientific discussions and support related to
the variety of aspects of SThM operation. We appreciate help of Riccardo Mazzocco with some of
illustrations and grateful to Bob Geer for providing ULSI samples, and Bob Jones for SEM analysis of
(a) (b)
(d) (c)
the probes. O.V.K. acknowledges support from the EPSRC grants EP/G015570/1, EP/K023373/1,
EPSRC-NSF grant EP/G06556X/1 and EU FP7 GRENADA and FUNPROBE grants. Authors
acknowledge use of WSxM and Gwiddion for analysis of SPM images.
References
[1] Binnig G, Rohrer H, Gerber C and Weibel E 1982 Tunneling through a controllable
vacuum gap Applied Physics Letters 40 178-80 [2] Binnig G, Quate C F and Gerber C 1986 Atomic force microscope Physical Review
Letters 56 930-3 [3] Butt H J, Cappella B and Kappl M 2005 Force measurements with the atomic force
microscope: Technique, interpretation and applications Surf. Sci. Rep. 59 1-152 [4] Benstetter G, Biberger R and Liu D P 2009 A review of advanced scanning probe
microscope analysis of functional films and semiconductor devices Thin Solid Films 517 5100-5
[5] Kolosov O V, Castell M R, Marsh C D, Briggs G A D, Kamins T I and Williams R S 1998 Imaging the elastic nanostructure of Ge islands by ultrasonic force
microscopy Physical Review Letters 81 1046-9 [6] Garcia R and Perez R 2002 Dynamic atomic force microscopy methods Surf. Sci.
Rep. 47 197-301
[7] Dobson P S, Mills G and Weaver J M R 2005 Microfabricated temperature standard based on Johnson noise measurement for the calibration of micro- and nano-thermometers Review of Scientific Instruments 76
[8] Wang L and Li B 2007 Thermal logic gates: Computation with phonons Physical Review Letters 99
[9] Ioffe Z, Shamai T, Ophir A, Noy G, Yutsis I, Kfir K, Cheshnovsky O and Selzer Y 2008 Detection of heating in current-carrying molecular junctions by Raman
scattering Nature Nanotechnology 3 727-32 [10] Chen G and Shakouri A 2002 Heat transfer in nanostructures for solid-state energy
conversion Journal of Heat Transfer-Transactions of the Asme 124 242-52 [11] Williams C C and Wickramasinghe H K 1986 SCANNING THERMAL PROFILER
Applied Physics Letters 49 1587-9 [12] Nonnenmacher M and Wickramasinghe H K 1992 SCANNING PROBE MICROSCOPY
OF THERMAL-CONDUCTIVITY AND SUBSURFACE PROPERTIES Applied Physics Letters 61 168-70
[13] Chui B W, Stowe T D, Kenny T W, Mamin H J, Terris B D and Rugar D 1996 Low-stiffness silicon cantilevers for thermal writing and piezoresistive readback with the atomic force microscope Applied Physics Letters 69 2767-9
[14] Kim K, Jeong W H, Lee W C and Reddy P 2012 Ultra-High Vacuum Scanning Thermal Microscopy for Nanometer Resolution Quantitative Thermometry Acs Nano
6 4248-57 [15] Yu Y-J, Han M Y, Berciaud S, Georgescu A B, Heinz T F, Brus L E, Kim K S and Kim
P 2011 High-resolution spatial mapping of the temperature distribution of a Joule self-heated graphene nanoribbon Applied Physics Letters 99 183105-3
[16] Majumdar A 1999 Scanning thermal microscopy Annu. Rev. Mater. Sci. 29 505-85 [17] Shi L, Plyasunov S, Bachtold A, McEuen P L and Majumdar A 2000 Scanning
thermal microscopy of carbon nanotubes using batch-fabricated probes Applied
Physics Letters 77 4295-7 [18] Tsukruk V V, Gorbunov V V and Fuchigami N 2003 Microthermal analysis of
polymeric materials Thermochim. Acta 395 151-8 [19] Pumarol M E, Rosamond M C, Tovee P, Petty M C, Zeze D A, Falko V and Kolosov O
V 2012 Direct Nanoscale Imaging of Ballistic and Diffusive Thermal Transport in Graphene Nanostructures Nano Letters 12 (6) 2906–11
[20] Shi L and Majumdar A 2002 Thermal transport mechanisms at nanoscale point contacts Journal of Heat Transfer-Transactions of the Asme 124 329-37
[21] Luo K, Lederman M and Majumdar A 1997 Liquid-film-mediated scanning thermal microscopy of a magnetoresistive reading head Microscale Thermophysical Engineering 1 333-45
[22] Li M H and Gianchandani Y B 2003 Applications of a low contact force polyimide shank bolometer probe for chemical and biological diagnostics Sensors and
Actuators a-Physical 104 236-45
[23] Prokop A F, Vaezy S, Noble M L, Kaczkowski P J, Martin R W and Crum L A 2003
Polyacrylamide gel as an acoustic coupling medium for focused ultrasound therapy Ultrasound in Medicine and Biology 29 1351-8
[24] Brakenhoff G J, Blom P and Barends P 1979 CONFOCAL SCANNING LIGHT-
MICROSCOPY WITH HIGH APERTURE IMMERSION LENSES J. Microsc.-Oxf. 117 219-32
[25] Hinz M, Marti O, Gotsmann B, Lantz M A and Durig U 2008 High resolution vacuum scanning thermal microscopy of HfO2 and SiO2 Applied Physics Letters 92 3
[26] Okabe K, Inada N, Gota C, Harada Y, Funatsu T and Uchiyama S 2012 Intracellular temperature mapping with a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy Nature communications 3
[27] Aigouy L, Lalouat L, Mortier M, Low P and Bergaud C 2011 Note: A scanning thermal probe microscope that operates in liquids Review of Scientific Instruments 82
[28] Hansma H G, Kim K J, Laney D E, Garcia R A, Argaman M, Allen M J and Parsons S M 1997 Properties of biomolecules measured from atomic force microscope images: A review J. Struct. Biol. 119 99-108
[29] Tovee P, Pumarol M E, Zeze D A, Kjoller K and Kolosov O 2012 Nanoscale spatial resolution probes for Scanning Thermal Microscopy of solid state materials J. Appl. Phys. 112 114317
[30] Geer R E, Kolosov O V, Briggs G A D and Shekhawat G S 2002 Nanometer-scale mechanical imaging of aluminum damascene interconnect structures in a low-dielectric-constant polymer Journal of Applied Physics 91 4549-55
[31] Balandin A A 2011 Thermal properties of graphene and nanostructured carbon
materials Nat. Mater. 10 569-81 [32] Zhou H, Midha A, Mills G, Thoms S, Murad S K and Weaver J M R 1998 Generic
scanned-probe microscope sensors by combined micromachining and electron-beam lithography J. Vac. Sci. Technol. B 16 54-8
[33] Kim K, Chung J, Hwang G, Kwon O and Lee J S 2011 Quantitative Measurement with Scanning Thermal Microscope by Preventing the Distortion Due to the Heat Transfer through the Air Acs Nano 5 8700-9
[34] Kolosov O V, Grishin I and Jones R 2011 Material sensitive scanning probe microscopy of subsurface semiconductor nanostructures via beam exit Ar ion polishing Nanotechnology 22 8
[35] Nika D L, Ghosh S, Pokatilov E P and Balandin A A 2009 Lattice thermal conductivity of graphene flakes: Comparison with bulk graphite Applied Physics Letters 94 203103-3
[36] Vivekchand S R C, Rout C S, Subrahmanyam K S, Govindaraj A and Rao C N R 2008 Graphene-based electrochemical supercapacitors Journal of Chemical Sciences 120 9-13
[37] Zabel H 2001 Phonons in layered compounds Journal of Physics-Condensed Matter 13 7679-90
[38] Barrat J L and Chiaruttini F 2003 Kapitza resistance at the liquid-solid interface Mol. Phys. 101 1605-10
[39] Weisenhorn A L, Maivald P, Butt H J and Hansma P K 1992 Measuring adhesion, attraction, and repulsion between surfaces in liquids with an atomic force microscope. Physical Review B 45 11226-32
[40] Greffet J J and Carminati R 1997 Image formation in near-field optics Progress in Surface Science 56 133-237
[41] Parmeggiani A, Julicher F, Ajdari A and Prost J 1999 Energy transduction of
isothermal ratchets: Generic aspects and specific examples close to and far from
equilibrium Physical Review E 60 2127-40 [42] Gust D, Moore T A and Moore A L 2001 Mimicking photosynthetic solar energy
transduction Accounts Chem. Res. 34 40-8