Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy Peter D Tovee and Oleg V Kolosov 1 Physics Department, Lancaster University, Lancaster, LA1 3BE, UK. 1 Author to whom any correspondence should be addressed E-mail: [email protected] Abstract. Nanoscale heat transport is of increasing importance as it often defines performance of modern processors and thermoelectric nanomaterials, and affects functioning of chemical and biosensors. Scanning Thermal Microscopy (SThM) is the leading tool for nanoscale mapping of thermal properties, but it is often negatively affected by unstable tip-surface thermal contacts. While operating SThM in liquid environment may allow unimpeded thermal contact and open new application areas, it was so far regarded impossible due to increased heat dissipation into liquid, and perceived non- local thermal interaction between the probe and the sample. Nevertheless, in this paper we show for the first time that such liquid immersion SThM (iSThM) is fully feasible and has sufficient thermal contrast to detect thermal conductivity variations in the few tens of nm thick graphite nanoflake and metal-polymer nanostructured interconnects. Its spatial resolution was on the order of 50 nm, equal to the resolution of the same probe in the standard air environment. These results confirm localized thermal sensing in iSThM and, coupled with absence of tip snap-in due to elimination of capillary forces, suggest the possibility for true non-contact nanoscale thermal mapping in liquids, including thermal phenomena in energy storage devices, catalysts and biosystems. PACS: 1. Introduction. Since its invention, scanning probe microscopy (SPM) [1, 2] became an indispensable tool of modern nanotechnology. One of major advantages of SPM is its ability to sense diverse physical and chemical properties of nanostructures with nanometer resolution [3-5] including operation in various environments [6]. In particular, nanoscale temperature measurements [7], heat generation and nanoscale heat propagation are of increasing importance due to continuous decrease of size of semiconductor devices with concurrent increase of processing power [8-10]. While active Scanning Thermal Microscopy (SThM) [11-22] that uses self- heated thermal sensors in contact with the studied sample allows nanoscale mapping of thermal properties, a weak thermal coupling between sensor and the sample is one of major SThM problems [16]. Furthermore, this coupling fluctuates while scanning and is also affected by sample geometry, overall significantly reducing SThM performance in nanoscale thermal measurements. It would be very tempting to use liquid immersion in SThM to improve both the thermal contact between the probe tip and the sample as well as contact uniformity. The approach would be somewhat similar to one used in ultrasonic imaging where dedicated gel is used to achieve better acoustic coupling [23] or optical microscopy where immersion reduces light reflection, refraction and scattering at the interfaces [24]. While the role of liquid film

Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

Mapping nanoscale thermal transport in liquid environment - immersion scanning

thermal microscopy

Peter D Tovee and Oleg V Kolosov1

Physics Department, Lancaster University, Lancaster, LA1 3BE, UK.

1Author to whom any correspondence should be addressed

E-mail: [email protected]

Abstract.

Nanoscale heat transport is of increasing importance as it often defines performance

of modern processors and thermoelectric nanomaterials, and affects functioning of

chemical and biosensors. Scanning Thermal Microscopy (SThM) is the leading tool

for nanoscale mapping of thermal properties, but it is often negatively affected by

unstable tip-surface thermal contacts. While operating SThM in liquid environment

may allow unimpeded thermal contact and open new application areas, it was so far

regarded impossible due to increased heat dissipation into liquid, and perceived non-

local thermal interaction between the probe and the sample. Nevertheless, in this

paper we show for the first time that such liquid immersion SThM (iSThM) is fully

feasible and has sufficient thermal contrast to detect thermal conductivity variations

in the few tens of nm thick graphite nanoflake and metal-polymer nanostructured

interconnects. Its spatial resolution was on the order of 50 nm, equal to the resolution

of the same probe in the standard air environment. These results confirm localized

thermal sensing in iSThM and, coupled with absence of tip snap-in due to

elimination of capillary forces, suggest the possibility for true non-contact nanoscale

thermal mapping in liquids, including thermal phenomena in energy storage devices,

catalysts and biosystems.

PACS:

1. Introduction.

Since its invention, scanning probe microscopy (SPM) [1, 2] became an indispensable tool of

modern nanotechnology. One of major advantages of SPM is its ability to sense diverse

physical and chemical properties of nanostructures with nanometer resolution [3-5] including

operation in various environments [6]. In particular, nanoscale temperature measurements [7],

heat generation and nanoscale heat propagation are of increasing importance due to

continuous decrease of size of semiconductor devices with concurrent increase of processing

power [8-10]. While active Scanning Thermal Microscopy (SThM) [11-22] that uses self-

heated thermal sensors in contact with the studied sample allows nanoscale mapping of

thermal properties, a weak thermal coupling between sensor and the sample is one of major

SThM problems [16]. Furthermore, this coupling fluctuates while scanning and is also

affected by sample geometry, overall significantly reducing SThM performance in nanoscale

thermal measurements.

It would be very tempting to use liquid immersion in SThM to improve both the thermal

contact between the probe tip and the sample as well as contact uniformity. The approach

would be somewhat similar to one used in ultrasonic imaging where dedicated gel is used to

achieve better acoustic coupling [23] or optical microscopy where immersion reduces light

reflection, refraction and scattering at the interfaces [24]. While the role of liquid film

Page 2: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

between the SThM tip apex is known to be essential [16, 17, 20, 21] up to now there were no

reports on heated nanoscale resolution SThM imaging while probe fully immersed in the

liquid. So far SThM operation both in air and vacuum was demonstrated, with vacuum

helping to eliminate heat dissipation through air [14, 19, 25]. The only reported so far in-

liquid nanoscale thermal measurements used passive fluorescence thermometry [26], that

while having potential for sub-micrometer spatial resolution [27] is not capable of

measurements of local thermal transport or thermal conductivities as it relies on the externally

created heat flux. If feasible, SThM liquid immersion would improve and stabilize thermal

contact between the tip and the surface, compared to in-air or vacuum environment. Also, due

to efficient heat transfer through liquid, it might be possible to perform truly non-contact

scanning with the tip-surface separated by few nm gap, while retaining both nanoscale

resolution and thermal sensitivity. Such in-liquid SThM, would be of extreme interest for

biotechnology, where it will allow handling of delicate biological samples [28] and in

exploration of energy generation and dissipation in rechargeable batteries, fuel cells and

liquid phase catalysts.

Unfortunately, until now fully immersed operation of SThM has been considered all but

impossible due to the potentially overwhelming direct heat dissipation from the heated sensor

into the surrounding liquid, that was perceived to result in the non-local thermal sensing and

degradation of lateral resolution [16]. To our knowledge, there is so far no publication

reporting such approach and measurements. Notwithstanding this rationale, in this paper we

show that such immersion SThM, or iSThM, can be successfully realized using certain design

of a SThM probe that is fully immersed in a liquid [29]. We found, surprisingly, that iSThM

performance would not be qualitatively different from the in-air or in-vacuum environment

operation [19, 20, 25]. We then apply iSThM to explore the heat transport in polymer-metal

ultra large scale integration interconnects [30], and in few tens of nm thick graphite nanoflake

[31] on Si substrate. In these nanostructures we observe 50 nm lateral resolution to local

thermal conductance that confirmed a local nature of iSThM thermal contrast, with

experimental finding supported by the numerical simulations that allowed to understand the

underlying nature and imaging mechanisms of a new approach.

2. Methods and materials

2.1 Finite elements modeling of SThM probes in air and liquid environment.

In order to explore the feasibility of iSThM and to find optimal experimental approach, we

first simulated behavior of various SThM probes in air and liquid environments. The

simulations were based on commercial finite elements (FE) (COMSOL Multiphysics)

approach in the 3D probe geometry. We used COMSOL AC/DC module for modeling the

current flow, Joule heating of the probe and a probe resistance that reflected probe

temperature, as well as thermal module for modeling of heat transport [29]. Given that mean-

free-path length of heat carriers (phonons in dielectrics and electrons in metals) in relevant

materials in the model were generally on the order of 10-25 nm, and the minimal

characteristic dimensions of the probe geometrical elements were 50 nm or larger, a diffusive

approximation and Fourier heat transport equations were deemed to be adequate [19].

Page 3: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

Figure 1. FE modeling of spatial temperature distribution for

iSThM for (a) DS and (b) SP probe; the heating power was

normalized to produce the same maximum T of the probe,

dodecane immersion was used. (c, d) Comparison of high

temperature field in the vicinity of tip apex for in-air (SThM)

and in-liquid iSThM in contact with Si sample; same heating

power was used. Dotted lines in the images indicate the

sample surface.

At first glance, the direct heat dissipation from SThM probe to the surrounding liquid might

result in the complete loss of sensitivity to local thermal properties of the sample and lead to

non-localized thermal response [16, 20]. In fact, FE modeling of a widely used doped Si

probe (DS) [13, 29] (AN-200, TA Instruments) in dodecane (this liquid was selected for its

low-volatility, moderate thermal conductivity and a non-corrosiveness) supported such

general belief showing that the heat plum is concentrated near the heater and far from the

sample (Figure 1(a)). Such heat distribution would indeed significantly decrease sample

related thermal signal and spatial resolution. Surprisingly, at the same time, FE analysis of

another widely used design of Si3N4 probe with Pd resistive element at the end of the probe

tip (SP probe) (Kelvin Nanotechnologies) [29, 32] showed a distinctive narrow heat plum

concentrated near the end of the probe (Figure 1(b). The absolute value of the SP probe

temperature with respect to the environment was only slightly lower in liquid - 35 degrees vs

54 degrees in air, corresponding to only 35% loss of thermal signal (see temperature scale in

Figure 1 (c,d). More significantly, a temperature field near the probe apex shows almost

identical pattern of the spatial distribution of temperature for SP probe in- air (Figure 1(c) and

in liquid (Figure 1(d). These finding strongly suggested that SP should be a probe of choice

for iSThM experimental trials.

(c) (d)

(b)

(a)

293 K

343 K

5 m

5 m

200 nm 200 nm

doped Si (DS) probe in-liquid

SP probe in-air

293 K

343 K

Si3N4/Pd (SP) probe in-liquid

SP probe in-liquid

Page 4: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

2.2. Experimental setup of SThM and thermal measurements.

Our iSThM experiments used a general purpose SPM (Bruker Multi-Mode, Nanoscope III)

with “half-moon” SThM probes holder (Anasys Instruments) that was modified for using

thermal probe in liquids as shown in Figure 2. A special PTFE cup was used to contain the

liquid as well as to keep the sample, thermal cantilevers and connecting leads immersed in

liquid. A glass window was used to create a flat refraction interface for SPM laser beam that

monitors cantilever deflection. A nitrile rubber thin sheet was used underneath the liquid

holder to protect the scanner from accidental liquid spilling.

Figure 2. Probe and sample arrangement in iSThM.

The SP thermal probe was calibrated on a Peltier variable temperature plate (Echo Therm

IC20, Torrey Pines Scientific) at temperatures ranging from room temperature to 80C by

measuring probe electrical resistance as a function of the applied voltage and ambient

temperature. Two types of resistance measurements were used – in the first the probe formed

a part of a DC voltage divider in series with the fixed resistor, this method was found to be

highly accurate but slow and used predominantly during the calibration. The second method

combined low AC voltage signal at 91 kHz frequency that was used for resistance

measurements, and higher DC offset providing probe self-heating. In this method the probe

formed a part of a balanced Maxwell electric bridge, with its output measured via the lock-in

amplifier (SRS-830, Stanford Research Systems). In second mode the resulting signal rapidly

followed the resistance changes but had less absolute accuracy, this mode was mainly used

for real-time SThM imaging. The AC and DC voltage excitation for all measurements was

provided by the precision function generator (Model 3390, Keithley Instruments). Both

approaches indicated a linear dependence of the probe resistance on its temperature that was

expected as the metallic resistive sensing element was used. As the tip is brought in contact

with the surface during SThM imaging, some heat starts to flow into the sample cooling the

tip and, consequently, changing resistance of the sensor. Using a Maxwell bridge and

combined AC-DC excitation [29] the well-defined power can be applied to the sensor

generating Joule heat, with the tip temperature measured simultaneously. As the tip is

scanned across the sample, monitoring these values allows to create a thermal image with the

lower temperature of the probe corresponding to the higher local heat flux into the sample,

therefore allowing direct evaluation of its local thermal conductivity [16, 19, 33].

2.3 Sample preparation.

Two samples used in this study were selected for two interlinked purposes. First we targeted

to prove experimentally a feasibility of iSThM, its sensitivity to local thermal conductivity,

and thermal spatial resolution while imaging diverse materials, such as metals, polymers, and

semiconductors. Secondly, if iSThM approach is successful, we were interested in

Page 5: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

experimental exploration of differences of nanoscale thermal transport in air and in the liquid

environment when nature of thermal contact between the material and surrounding liquid

immersion may modify such transport. First sample was a metal-polymer nanostructure,

where Al damascene embedded layer [30] was enclosed in benzocyclobutene (BCB) low-k

dielectric, this sample was used to represent morphology and materials of the ultra large scale

integration interconnects (ULSI). Heat transport in ULSI nanostructures is of significant

concern as metallization tracks in a real device carry significant amount of current and their

overheating would increase the electro-migration and adversely affect the stability of the

semiconductor device [30]. High resolution lithography used in the sample preparation

provided a well-defined boundary between metal and BCB, while the chemo-mechanical

polishing provided relatively flat surfaces with moderate topographical contrast. The second

sample was in-house exfoliated a few layer graphene/graphite nanoflakes with thicknesses up

to few tens of nm deposited on Si wafer with 300 nm thermal oxide layer on the top. The

ULSI interconnects were cleaned by 10 min sonication consecutively in acetone, ethanol, and

DI water, with final plasma cleaning performed in O2/Ar plasma for 5 minutes. Such stringent

procedure removes any residual organic contaminants on the surface. The Si wafer prior to

the deposition of nanoflakes was cleaned using the same procedure, and nanoflake was then

mechanically exfoliated from Kish graphite lumps using pressure sensitive tape, with the final

exfoliation step performed by cross-linked polymer gel (Gel-Pak, USA) that helped to

minimize tape residue transfer [19].

3. Results and discussion

3.1 Feasibility of iSThM: sensing thermal conductivity with nanoscale resolution and local

nature of iSThM response.

The feasibility of liquid environment iSThM operation was first tested on ULSI interconnect

structures described above. The measurements were performed by the probe first operated in-

air and then in-the-liquid dodecane environment, allowing making relevant and definitive

comparisons as exactly the same probe was used. Topography images in both environments

shown in Figure 3(a,b) reveal similar features - a protruding central Al metallization lead with

few voids (that are usually located at Al grain boundaries [34]) embedded in the BCB

polymer matrix. The in-air SThM image in Figure 3(c) obtained at a constant Joule heating

power applied to the sensor, clearly shows that the Al interconnects produce better heat

dissipation (darker image contrast reflects the lower temperature of the probe due to increased

heat flow from the probe). This is consistent with the higher thermal conductivity for Al, kAl =

200 Wm-1

K-1

compared to thermal conductivity of BCB, kBCB = 29 Wm-1

K-1

. The absolute

topographical height (~ 80 nm) seemed to provide no direct influence for in-air thermal

image, at the same time the “rim” of Al lead looked brighter. One can expect certain increase

of heat transport at the Al edge due to increased contact area with the side of SThM tip, and

hence darker SThM contrast, but this was not observed. Most likely the nanoscale roughness

of the side edge created a barrier to the heat transport resulting in it imaged as “hotter” -

brighter areas in in-air SThM images.

iSThM thermal image in Figure 3(d) shows qualitatively same features – darker Al

metallization layer with better heat dissipation surrounded by the brighter, lower heat

conductance BCB matrix. As for in-air SThM thermal image, the absolute topographical

height of the Al layer (~ 80 nm) provided no direct influence on the iSThM thermal image,

confirming the local nature of the probing. The lateral resolution of iSThM was similar to the

resolution of in-air SThM, as seen from the comparison of line profiles given in Figure 3(e).

Page 6: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

This was further supported by FE simulation of the same profiles in Figure 3(d) where the

thermal signal across the interface between Al and BCB polymer shows excellent qualitative

correspondence with experimentally obtained SThM and iSThM profiles. In both modes, the

thermal signal on the Al – BCB polymer boundary shows appreciable change over

approximately 50 nm distance, in good correlation with the experimental results. The

experimentally measured signal-to-noise ratio of iSThM thermal image was lower compared

to in-air SThM, that was most likely linked with the additional heat dissipation into the liquid

adding to the common for SThM and iSThM modes heat dissipation to the cantilever base.

Nevertheless, the thermal signal was fully sufficient for nanoscale mapping of thermal

conductivity in ULSI nanostructure in iSThM. While more definitive comparison of the

lateral resolution in iSThM and SThM is given later in the paper using a well-defined edge of

graphite nanoflake, data in Figure 3 clearly indicate that iSThM operating in liquid

environment is feasible and capable of nanoscale mapping of local thermal conductivities.

The interesting observation was that in contrast to in-air SThM, the voids in Al (observed in

both topographical images) did not produce significant increase in thermal response in iSThM

suggesting that the immersion liquid secured direct thermal contact of the probe and the

studied material. Also a darker edge around Al lead that indicated higher heat transport to the

side of the lead was observed without lighter “rim” in iSThM. These observations suggest

that iSThM has potential of eliminating detrimental effects of surface roughness, and can

reflect more directly the intrinsic heat transport in nanostructures.

Page 7: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

Figure 3. In-air SThM and iSThM images of Al - BCB

polymer interconnects sample. (a) In-air SThM topography

(height) and (c) thermal images. (b) In-dodecane iSThM

topography and (d) thermal images. Thermal images are

obtained in a constant power mode, dark contrast

corresponds to lower probe temperature due to higher heat

dissipation to the sample that reflects higher local thermal

conductivity. (e) Comparison of experimentally measured

line profiles of thermal signal for SThM and iSThM across

Al-BCB boundary. (d) Results of the FE simulation

comparing line profiles in SThM and iSThM across Al-

BCB boundary.

3.2 iSThM mapping of thermal transport in thermally anisotropic graphite nanoflake.

The iSThM was then applied to investigate thermal conductivity of graphite nanoflakes of

approximately 40 nm thickness on Si substrate (Figure 4). Thermal properties of a few layer

graphene and graphite exhibit extremely anisotropic thermal conductivity that depends on the

direction of the heat flux. Ratio of thermal conductivity parallel and perpendicular to

graphene planes [35] can reach three orders of magnitude (k║-Gr-plane = 2000 Wm-1

K-1

k-Gr-plane

= 2 Wm-1

K-1

) with thermal conductivity in graphene plane exceeding one of Si (kSi = 130

Wm-1

K-1

), whereas conductivity normal to graphene planes being two orders of magnitude

lower that thermal conductivity of Si. Such aspects may play some role in the heat dissipation

in rechargeable batteries, supercapacitors and fuel cells where graphene and graphite is used

in liquid environment [36] with iSThM offering a feasible approach for such studies.

Z: 80 nm

voids voids

Z: 80 nm (a) (b)

Al lead

(e) (f)

BCB Al Al

BCB

Page 8: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

Thermal images in Figure 4(c,d) and corresponding line profiles (Figure 4(e,f) show that for

in-air SThM the heat transport is slightly increased in the area of the flake, and the side of the

flake, with clear decrease of heat transport at the flake “rim” (tip position iii, Figure 4(g,h). At

the same time, iSThM thermal image seem to be less affected by the “rim” contrast,

presumably, due to better thermal link between the tip and the sample that is liquid mediated

and less affected by the local surface corrugations. Moreover, the heat transport in the area of

the flake (area iv, as illustrated in the Figure 5(g,h) is slightly below one of Si. That can be

linked with the fact that in-liquid a higher proportion of the heat flux is normal to graphene

layers along the direction of the lower thermal conductivity (k-Gr-plane = 2 Wm-1

K-1

compared

to kSi= 130 Wm-1

K-1

) [37] or with different interfacial Kapitza resistance [38]. The side

surface of the flake provides a better heat dissipation (tip position ii) for both in-air and

iSThM due to high in-plane conductivity of graphene layers (k║-Gr-plane = 2000 Wm-1

K-1

). The

FE simulation of the profile across nanoflake-substrate boundary in Figure 4(i) show slightly

increased heat transport for in-air SThM in the flake area compared to Si substrate, whereas

heat transport for iSThM being reduced in the flake area. The sign of the heat dissipation

difference matches well with the one experimentally observed in Figure 4(e,f). Moreover, the

simulation shows that the spatial variation of the heat dissipation due to presence of the flake

“rim” are reduced in iSThM in good correspondence with experimental data.

Finally, it is to be noted that the full width of half maximum (FWHM) of the flake edge for

iSThM was 56 nm compared with 78 nm for in-air SThM obtained with the same probe

(Figure 4(e,f), confirming the local nature of iSThM thermal response and indicating at least

similar lateral resolution for comparable probes and the samples.

Page 9: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

Figure 4. SThM and iSThM nanoscale mapping of thermal

conductivity in graphite nanoflakes. (a) In-air topography and (c)

corresponding thermal image of 40 5 nm thick nanoflake. iSThM

(b) topography and (d) thermal image of a similar flake with 45

5 nm thickness. (g, h) Schematic illustration of different regions in

the images with SthM tip positioned on: i - the substrate, ii –

touching the edge of the flake (thermal contact area increased), iii

– on the “rim” of the flake (contact area decreased), iv - on the top

of the flake. (i) Simulated SThM and iSThM profiles across the

edge of graphite nanoflake.

“rim”, iii

flake edge, ii flake edge, ii

edge width

edge width

z: 45 nm

z:

40 nm

iv i ii

iii

ii

iii iv

substrate

flake

flake

substrate

(a) (b)

(e) (f)

i

iv

(g) (h)

flake edge

“rim”

substrate flake

(i)

Page 10: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

3.3 Force contact phenomena in iSThM.

As we observed above, iSthM provides efficient through-the-liquid thermal coupling of the

probe and the sample that eliminates some effects of the surface roughness and voids, e.g. in

ULSI in Figure 2. In principle, that would allow the true non-contact thermal imaging with

the tip hovering at few nm above the studied surface, and enable study of delicate samples

such as biological materials, porous and suspended nanostructures. We have performed FE

simulations that indicated that 50 nm wide tip “hovering” above sample surface at 25 nm

distance would retain 80% of the iSThM in-contact thermal signal, whereas in-air SThM will

retain less than half of such signal.

In order to analyze the non-contact performance of iSThM, we captured simultaneously

thermal signal and mechanical deflection of SThM sensor (proportional to force between the

sample and SThM tip) as the tip approached the sample (Figure 5) similar for in-air

measurements in [20]. In either environment as the tip approaches the surface, the thermal

signal notably decreases, as the heat conducted to the sample via either air [20] or liquid

media cools the probe. For in-air SThM (Figure 5(a,b) there is a well-defined “snap-in” of the

tip towards the surface that is linked with the well-documented formation of meniscus [20,

37] that also leads to the step-wise increase of the pull-in force helping to establish the solid-

solid contact. Such behavior is typical for the relatively compliant cantilever with the sharp

tips like the one used in our study. Once the capillary meniscus and solid-solid contact is fully

established, the thermal signal remains mainly constant even as the contact force increases.

When the sample is retracted, the combined adhesive and meniscus forces lead to even

stronger “snap-off” that results in the jump-off of the cantilever and similar changes in the

thermal response.

In the liquid environment of iSThM the situation was quite different – no clear “snap-in” or

“snap-out” force jumps were observed (Figure 5(c) as it would be expected due to the absence

of capillary forces [39]. Also, no jump of heat dissipation (Figure 5(d) on the solid-solid

contact was observed as it would be for in-air or in-vacuum environments [25]. The absence

of “thermal” jump in combination with the spatial resolution demonstrated in Figures 3(e) and

4(f) suggest that iSThM sensing of local thermal conductivity of the sample is almost fully

liquid mediated. The observed absence of the capillary “snap-in” and “snap-out” in iSThM

coupled with demonstrated in this paper similar to in-air SThM 50 nm lateral resolution to

thermal properties, would make it possible to realize true non-contact nanoscale thermal

imaging by “hovering” iSThM tip in the few to 10 nm above the sample, maintaining the

distance via e.g. well-known shear force feedback [40] that would be easily realized due to

non-zero viscosity of coupling liquid.

Page 11: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

Figure 5. Experimental approach-retract curves for SThM

and iSThM probe and Si sample. (a) Force and (b) in-air

SThM thermal signal compared with (c) force and (d) in-

dodecane iSThM thermal signal; approach-retract rate of

0.01 Hz was used.

4. Conclusions

This study demonstrates for the first time that active heating nanoscale SThM thermal

probing in a fully immersed liquid environment (iSThM) is feasible. The iSThM was shown

to be sensitive to the local thermal conductivity of materials ranging from polymers (BCB)

and semiconductors (Si) to metals (Al) and graphite nanoflakes. The effective lateral

resolution on the order of 50 nm was demonstrated using a widely used microfabricated

resistive probe design operating in iSThM mode, and shown to be very similar to the lateral

resolution of the same probe operated in air. Using FE modeling we found that the probe

design may play crucial role for iSThM performance, suggesting that dedicated optimization

of probe for iSThM, e.g. changing the geometry of the heater and the probe apex, can

significantly improve iSThM resolution and performance. The iSThM thermal response was

shown to be in good qualitative agreement with numerical simulations, that supported

experimentally observed iSThM spatial resolution and sensitivity. We confirmed that the heat

flux between the probe and the sample that defines the nanoscale spatial resolution of iSThM

is predominantly conducted through liquid rather solid-solid contact, that may help to

eliminate one of major uncertainties in the nanoscale mapping of heat transport via active

SThM – instability of tip-surface thermal contact. Moreover, such liquid mediated iSThM

should make it possible to realize true non-contact nanoscale thermal imaging by “hovering”

iSThM tip in the vicinity of the sample. We believe that iSThM can open new possibilities for

exploration of heat generated in biological systems [41, 42], and help to investigate nanoscale

thermal phenomena in power batteries, fuel cells, and nanoscale catalysts.

Acknowledgment

Authors acknowledge input of Manuel Pumarol for advice, scientific discussions and support related to

the variety of aspects of SThM operation. We appreciate help of Riccardo Mazzocco with some of

illustrations and grateful to Bob Geer for providing ULSI samples, and Bob Jones for SEM analysis of

(a) (b)

(d) (c)

Page 12: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

the probes. O.V.K. acknowledges support from the EPSRC grants EP/G015570/1, EP/K023373/1,

EPSRC-NSF grant EP/G06556X/1 and EU FP7 GRENADA and FUNPROBE grants. Authors

acknowledge use of WSxM and Gwiddion for analysis of SPM images.

References

[1] Binnig G, Rohrer H, Gerber C and Weibel E 1982 Tunneling through a controllable

vacuum gap Applied Physics Letters 40 178-80 [2] Binnig G, Quate C F and Gerber C 1986 Atomic force microscope Physical Review

Letters 56 930-3 [3] Butt H J, Cappella B and Kappl M 2005 Force measurements with the atomic force

microscope: Technique, interpretation and applications Surf. Sci. Rep. 59 1-152 [4] Benstetter G, Biberger R and Liu D P 2009 A review of advanced scanning probe

microscope analysis of functional films and semiconductor devices Thin Solid Films 517 5100-5

[5] Kolosov O V, Castell M R, Marsh C D, Briggs G A D, Kamins T I and Williams R S 1998 Imaging the elastic nanostructure of Ge islands by ultrasonic force

microscopy Physical Review Letters 81 1046-9 [6] Garcia R and Perez R 2002 Dynamic atomic force microscopy methods Surf. Sci.

Rep. 47 197-301

[7] Dobson P S, Mills G and Weaver J M R 2005 Microfabricated temperature standard based on Johnson noise measurement for the calibration of micro- and nano-thermometers Review of Scientific Instruments 76

[8] Wang L and Li B 2007 Thermal logic gates: Computation with phonons Physical Review Letters 99

[9] Ioffe Z, Shamai T, Ophir A, Noy G, Yutsis I, Kfir K, Cheshnovsky O and Selzer Y 2008 Detection of heating in current-carrying molecular junctions by Raman

scattering Nature Nanotechnology 3 727-32 [10] Chen G and Shakouri A 2002 Heat transfer in nanostructures for solid-state energy

conversion Journal of Heat Transfer-Transactions of the Asme 124 242-52 [11] Williams C C and Wickramasinghe H K 1986 SCANNING THERMAL PROFILER

Applied Physics Letters 49 1587-9 [12] Nonnenmacher M and Wickramasinghe H K 1992 SCANNING PROBE MICROSCOPY

OF THERMAL-CONDUCTIVITY AND SUBSURFACE PROPERTIES Applied Physics Letters 61 168-70

[13] Chui B W, Stowe T D, Kenny T W, Mamin H J, Terris B D and Rugar D 1996 Low-stiffness silicon cantilevers for thermal writing and piezoresistive readback with the atomic force microscope Applied Physics Letters 69 2767-9

[14] Kim K, Jeong W H, Lee W C and Reddy P 2012 Ultra-High Vacuum Scanning Thermal Microscopy for Nanometer Resolution Quantitative Thermometry Acs Nano

6 4248-57 [15] Yu Y-J, Han M Y, Berciaud S, Georgescu A B, Heinz T F, Brus L E, Kim K S and Kim

P 2011 High-resolution spatial mapping of the temperature distribution of a Joule self-heated graphene nanoribbon Applied Physics Letters 99 183105-3

[16] Majumdar A 1999 Scanning thermal microscopy Annu. Rev. Mater. Sci. 29 505-85 [17] Shi L, Plyasunov S, Bachtold A, McEuen P L and Majumdar A 2000 Scanning

thermal microscopy of carbon nanotubes using batch-fabricated probes Applied

Physics Letters 77 4295-7 [18] Tsukruk V V, Gorbunov V V and Fuchigami N 2003 Microthermal analysis of

polymeric materials Thermochim. Acta 395 151-8 [19] Pumarol M E, Rosamond M C, Tovee P, Petty M C, Zeze D A, Falko V and Kolosov O

V 2012 Direct Nanoscale Imaging of Ballistic and Diffusive Thermal Transport in Graphene Nanostructures Nano Letters 12 (6) 2906–11

[20] Shi L and Majumdar A 2002 Thermal transport mechanisms at nanoscale point contacts Journal of Heat Transfer-Transactions of the Asme 124 329-37

[21] Luo K, Lederman M and Majumdar A 1997 Liquid-film-mediated scanning thermal microscopy of a magnetoresistive reading head Microscale Thermophysical Engineering 1 333-45

[22] Li M H and Gianchandani Y B 2003 Applications of a low contact force polyimide shank bolometer probe for chemical and biological diagnostics Sensors and

Actuators a-Physical 104 236-45

Page 13: Mapping nanoscale thermal transport in liquid environment - … · 2013. 6. 7. · Mapping nanoscale thermal transport in liquid environment - immersion scanning thermal microscopy

[23] Prokop A F, Vaezy S, Noble M L, Kaczkowski P J, Martin R W and Crum L A 2003

Polyacrylamide gel as an acoustic coupling medium for focused ultrasound therapy Ultrasound in Medicine and Biology 29 1351-8

[24] Brakenhoff G J, Blom P and Barends P 1979 CONFOCAL SCANNING LIGHT-

MICROSCOPY WITH HIGH APERTURE IMMERSION LENSES J. Microsc.-Oxf. 117 219-32

[25] Hinz M, Marti O, Gotsmann B, Lantz M A and Durig U 2008 High resolution vacuum scanning thermal microscopy of HfO2 and SiO2 Applied Physics Letters 92 3

[26] Okabe K, Inada N, Gota C, Harada Y, Funatsu T and Uchiyama S 2012 Intracellular temperature mapping with a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy Nature communications 3

[27] Aigouy L, Lalouat L, Mortier M, Low P and Bergaud C 2011 Note: A scanning thermal probe microscope that operates in liquids Review of Scientific Instruments 82

[28] Hansma H G, Kim K J, Laney D E, Garcia R A, Argaman M, Allen M J and Parsons S M 1997 Properties of biomolecules measured from atomic force microscope images: A review J. Struct. Biol. 119 99-108

[29] Tovee P, Pumarol M E, Zeze D A, Kjoller K and Kolosov O 2012 Nanoscale spatial resolution probes for Scanning Thermal Microscopy of solid state materials J. Appl. Phys. 112 114317

[30] Geer R E, Kolosov O V, Briggs G A D and Shekhawat G S 2002 Nanometer-scale mechanical imaging of aluminum damascene interconnect structures in a low-dielectric-constant polymer Journal of Applied Physics 91 4549-55

[31] Balandin A A 2011 Thermal properties of graphene and nanostructured carbon

materials Nat. Mater. 10 569-81 [32] Zhou H, Midha A, Mills G, Thoms S, Murad S K and Weaver J M R 1998 Generic

scanned-probe microscope sensors by combined micromachining and electron-beam lithography J. Vac. Sci. Technol. B 16 54-8

[33] Kim K, Chung J, Hwang G, Kwon O and Lee J S 2011 Quantitative Measurement with Scanning Thermal Microscope by Preventing the Distortion Due to the Heat Transfer through the Air Acs Nano 5 8700-9

[34] Kolosov O V, Grishin I and Jones R 2011 Material sensitive scanning probe microscopy of subsurface semiconductor nanostructures via beam exit Ar ion polishing Nanotechnology 22 8

[35] Nika D L, Ghosh S, Pokatilov E P and Balandin A A 2009 Lattice thermal conductivity of graphene flakes: Comparison with bulk graphite Applied Physics Letters 94 203103-3

[36] Vivekchand S R C, Rout C S, Subrahmanyam K S, Govindaraj A and Rao C N R 2008 Graphene-based electrochemical supercapacitors Journal of Chemical Sciences 120 9-13

[37] Zabel H 2001 Phonons in layered compounds Journal of Physics-Condensed Matter 13 7679-90

[38] Barrat J L and Chiaruttini F 2003 Kapitza resistance at the liquid-solid interface Mol. Phys. 101 1605-10

[39] Weisenhorn A L, Maivald P, Butt H J and Hansma P K 1992 Measuring adhesion, attraction, and repulsion between surfaces in liquids with an atomic force microscope. Physical Review B 45 11226-32

[40] Greffet J J and Carminati R 1997 Image formation in near-field optics Progress in Surface Science 56 133-237

[41] Parmeggiani A, Julicher F, Ajdari A and Prost J 1999 Energy transduction of

isothermal ratchets: Generic aspects and specific examples close to and far from

equilibrium Physical Review E 60 2127-40 [42] Gust D, Moore T A and Moore A L 2001 Mimicking photosynthetic solar energy

transduction Accounts Chem. Res. 34 40-8