SwissQual ®... QualiPoc Remote Control Manual Manual Remote Control ─ 03 Test & Measurement

Manual - QualiPoc Remote Control

  • Upload
    cahit

  • View
    64

  • Download
    18

Embed Size (px)

DESCRIPTION

Manual - QualiPoc Remote Control

Citation preview

Page 1: Manual - QualiPoc Remote Control

SwissQual®...QualiPocRemote ControlManual

Manu

al

Remote Control ─ 03

Test

& Me

asur

emen

t

Page 2: Manual - QualiPoc Remote Control

The firmware of the instrument makes use of several valuable open source software packages. For information, see the "OpenSource Acknowledgement" on the user documentation CD-ROM (included in delivery).Rohde & Schwarz would like to thank the open source community for their valuable contribution to embedded computing.

© SwissQual AGAllmendweg 8, 4528 Zuchwil, SwitzerlandPhone: +41 32 686 65 65Fax:+41 32 686 65 66E-mail: [email protected]: http://www.swissqual.com/Printed in Germany – Subject to change – Data without tolerance limits is not binding.R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.Trade names are trademarks of the owners.SwissQual has made every effort to ensure that eventual instructions contained in the document are adequate and free of errors andomissions. SwissQual will, if necessary, explain issues which may not be covered by the documents. SwissQual’s liability for anyerrors in the documents is limited to the correction of errors and the aforementioned advisory services.Copyright 2000 - 2014 SwissQual AG. All rights reserved.No part of this publication may be copied, distributed, transmitted, transcribed, stored in a retrieval system, or translated into anyhuman or computer language without the prior written permission of SwissQual AG.Confidential materials.All information in this document is regarded as commercial valuable, protected and privileged intellectual property, and is providedunder the terms of existing Non-Disclosure Agreements or as commercial-in-confidence material.When you refer to a SwissQual technology or product, you must acknowledge the respective text or logo trademark somewhere inyour text.SwissQual®, Seven.Five®, SQuad®, QualiPoc®, NetQual®, VQuad®, Diversity® as well as the following logos are registered trade-marks of SwissQual AG.Diversity ExplorerTM, Diversity RangerTM, Diversity UnattendedTM, NiNA+TM, NiNATM, NQAgentTM, NQCommTM, NQDITM, NQTMTM,NQViewTM, NQWebTM, QPControlTM, QPViewTM, QualiPoc FreeriderTM, QualiPoc iQTM, QualiPoc MobileTM, QualiPoc StaticTM, Quali-Watch-MTM, QualiWatch-STM, SystemInspectorTM, TestManagerTM, VMonTM, VQuad-HDTM are trademarks of SwissQual AG.

Page 3: Manual - QualiPoc Remote Control

ContentsSwissQual®...QualiPoc

3Manual Remote Control ─ 03

Contents1 Introduction............................................................................................ 7

1.1 Overview........................................................................................................................ 7

2 Installation............................................................................................ 102.1 System Requirements................................................................................................ 10

2.2 Installing and Configuring QualiPoc......................................................................... 10

2.3 Power Supply.............................................................................................................. 13

2.4 Additional Information................................................................................................13

2.4.1 Status Icons.................................................................................................................. 13

2.4.2 RC Log Tab...................................................................................................................14

2.4.2.1 Data Network Status..................................................................................................... 15

3 Configuring QualiPoc Remote Control Units in NQView................. 173.1 Creating a QualiPoc Remote Control Unit................................................................ 17

3.2 Creating an Answering Station..................................................................................24

3.3 Creating QualiPoc Remote Control Jobs in NQView...............................................26

3.3.1 Battery Level and Disk Space....................................................................................... 26

3.3.2 Adding a Call Job.......................................................................................................... 27

3.3.2.1 Adding a Call to Any Number Job................................................................................. 27

3.3.2.2 Adding a Speech Double Ended Job............................................................................ 29

3.3.3 Creating a Data Job...................................................................................................... 31

3.3.3.1 Data Job Test Types..................................................................................................... 33

Capacity Test................................................................................................................ 33

Email Receive Test....................................................................................................... 34

Email Send Test............................................................................................................36

FTP Test....................................................................................................................... 37

HTTP Browser Test.......................................................................................................39

HTTP Transfer Test...................................................................................................... 39

MMS Receive Test........................................................................................................41

MMS Send Test............................................................................................................ 41

Ping Test....................................................................................................................... 42

SMS Receive Test........................................................................................................ 43

SMS Send Test............................................................................................................. 44

Page 4: Manual - QualiPoc Remote Control

ContentsSwissQual®...QualiPoc

4Manual Remote Control ─ 03

3.3.4 Adding an Idle Job........................................................................................................ 45

3.3.5 Adding an Intrusive Job.................................................................................................46

3.3.6 Adding an Upload Job...................................................................................................48

3.4 Defining a Task............................................................................................................49

3.5 Defining a Campaign.................................................................................................. 52

3.6 Monitoring Tasks........................................................................................................ 53

3.6.1 Available Commands.................................................................................................... 53

3.6.2 Unit Status.....................................................................................................................54

3.6.3 Workspace Tabs........................................................................................................... 54

3.6.3.1 General Tab.................................................................................................................. 55

3.6.3.2 Communication Tab...................................................................................................... 55

3.6.3.3 Data Upload Tab........................................................................................................... 56

3.6.3.4 Alerts and Action Tab....................................................................................................56

3.6.3.5 Tasks Tab..................................................................................................................... 56

3.6.3.6 Version Info Tab............................................................................................................57

3.7 Remotely Updating SwissQual Software.................................................................. 57

3.7.1 Monitoring the Update...................................................................................................60

4 QualiPoc Remote Control Operation on a Mobile Phone.................624.1 Remote Configuration................................................................................................ 62

4.1.1 Rebooting a Phone Remotely....................................................................................... 62

4.2 Measurement Jobs......................................................................................................62

4.2.1 Scheduling Measurements............................................................................................63

4.2.2 Running Measurements................................................................................................ 63

4.2.3 Post-Measurement Actions........................................................................................... 64

4.2.3.1 Manually Uploading Measurement Files....................................................................... 64

4.2.3.2 Upload Behaviour..........................................................................................................65

4.3 QualiPoc Remote Control Unit Information..............................................................65

4.3.1 Log File......................................................................................................................... 65

5 QualiPoc Remote Control Shell..........................................................665.1 Safety Instructions......................................................................................................66

5.1.1 Important Safety Information.........................................................................................67

5.1.2 Operation and Storage Conditions................................................................................67

5.1.2.1 Operating Conditions.................................................................................................... 67

Page 5: Manual - QualiPoc Remote Control

ContentsSwissQual®...QualiPoc

5Manual Remote Control ─ 03

5.1.2.2 Storage Conditions........................................................................................................68

5.2 Remote Control Shell Components...........................................................................68

5.2.1 QualiPoc Remote Control Device................................................................................. 69

5.2.2 Remote Control Shell.................................................................................................... 69

5.2.2.1 Connector Panel........................................................................................................... 70

5.2.2.2 Power Input Cable.........................................................................................................71

5.2.2.3 Office Power Adapter.................................................................................................... 72

5.3 Using a QualiPoc Remote Control Shell................................................................... 72

5.3.1 SIM Card....................................................................................................................... 72

5.3.2 Indoor Installation..........................................................................................................73

5.3.3 Vehicle Installation........................................................................................................ 73

5.3.4 Operation...................................................................................................................... 73

5.3.5 UPS Functionality..........................................................................................................74

5.4 Storage.........................................................................................................................75

5.5 Maintenance................................................................................................................ 75

5.5.1 Replacing Batteries....................................................................................................... 75

5.5.2 Cleaning........................................................................................................................ 76

5.6 Repair........................................................................................................................... 76

5.6.1 Replacing a Fuse.......................................................................................................... 76

5.7 Shipping.......................................................................................................................76

5.7.1 Warranty Information.....................................................................................................77

5.8 Troubleshooting..........................................................................................................77

5.8.1 Device Does Not Start Up............................................................................................. 77

5.8.2 CHG LED Does Not Turn Green or Blue After 4h When PWR IN is Connected.......... 78

5.9 Technical Specification.............................................................................................. 78

5.9.1 Dimensions and Weights.............................................................................................. 78

5.9.2 Drill Plan for Wall Mounting...........................................................................................79

5.9.3 Electrical and Conformance Specification.....................................................................80

5.10 Installing a QP RCS in a Vehicle................................................................................81

5.10.1 Mounting Options.......................................................................................................... 84

5.10.1.1 Side By Side Mounting..................................................................................................85

5.10.1.2 End to End Mounting.....................................................................................................85

5.10.2 Connecting the QP RCS PWR-IN Cable.......................................................................87

Page 6: Manual - QualiPoc Remote Control

ContentsSwissQual®...QualiPoc

6Manual Remote Control ─ 03

5.10.3 Connecting Antennas to RF Combiner......................................................................... 88

Glossary: Abbreviations......................................................................89

Page 7: Manual - QualiPoc Remote Control

IntroductionSwissQual®...QualiPoc

7Manual Remote Control ─ 03

1 IntroductionThis document describes how to configure your QualiPoc Remote Control unit, whichis a SwissQual QualiPoc device in Remote Control mode. This mode enables commu-nication between the QualiPoc Remote Control units and the backend components

1.1 Overview

Remote Control mode uses Diversity NQView to remotely manage and control Quali-Poc measurements and units.

NQDI Client

NQView

MultimediaServer

SMS Service

FTP Server

NQDI DatabaseServer (SQL)

Diversity VoiceCall Server

AnsweringStation

GSM / UMTS/ LTE

PSTN / ISDN

LAN

Internet

QualiPoc Unit QualiPoc Unit

Fig. 1-1: Remote Control mode overview

Remote Control mode requires the following software:

● QualiPoc Android application on the QualiPoc Remote Control unit● Diversity NQView on the controlling PC

Overview

Page 8: Manual - QualiPoc Remote Control

IntroductionSwissQual®...QualiPoc

8Manual Remote Control ─ 03

You can also install the following optional software on the controlling PC:

● NetQual NQDI post-processing software● NetQual NQWeb Automation Agent post-processing software

NQView

NQDIDatabaseNQDI Report

FTP Server

Mail Server

SMS Server

SNMP Console

Disc

NQCommService

Automation Agent

NQViewDatabase

NQDI Import

Disc

FTP Server

HTTP Service

WebReport

NQDI

Web BrowserDiversity

Voice Call Server

AnsweringStation

QualiPocApplication

InternalGPS

SMS:> POLL> ABORT> REBOOT> APN (not used)

Files:> stask_xxx.xml> cmd_xxx.xml> ConfigUpdate_xxx.zip< IPC_Device.xml< *.zip (Results, Logs)< IPC_Unit.xml< sta_xxx_finished.ini

NTPServer

SMSServer

SMS SNTPFTP

Use Use

Use Use

Fig. 1-2: QualiPoc Remote Control system architecture

The QualiPoc Remote Control system architecture contains the following components:

● QualiPoc unit: Standard Android OS-based consumer mobile phone with SwissQ-ual firmware and QualiPoc software to run the measurements. The QualiPoc soft-ware loads a job configuration and starts the measurement, starts the trace inter-face, provides GPS data, and opens a measurement file. The software starts auto-matically when you turn on the phone and remains active to enable communicationbetween the other QualiPoc Remote Control components and to start measure-ments on time. After the measurement completes, QualiPoc uploads the measure-ment files to an FTP server and informs NQView about the status of the device. Ifavailable, QualiPoc also provides network and position information. The unit alsocontains a watchdog service that automatically restarts QualiPoc if the applicationstops working. If the application restart does not solve the problem, the servicerestarts the phone and then QualiPoc.

● NQView: SwissQual software on your computer that configures and managesQualiPoc units and measurements. NQView stores the configuration and schedul-ing information in an SQL database and can display device and status information

Overview

Page 9: Manual - QualiPoc Remote Control

IntroductionSwissQual®...QualiPoc

9Manual Remote Control ─ 03

from a QualiPoc unit in real-time. For more information, see theManual - Diversity NQView.pdf document.

● NQWeb (optional): Web application to define routine jobs, which are scheduled torun at a specified time. NQWeb performs jobs such as importing measurement filesinto NQDI or sending an Email to inform you of a failed test. For more information,see the Manual - NQWeb.pdf document.

● NQDI and NQDI Database (optional): SwissQual post-processing software onyour computer that analyses and stores the measurement data in an SQL data-base. You can import the data manually or configure the Automation Agent to auto-matically import the data. For more information, see the Manual - NQDI.pdfdocument.

● NQComm Service: NQComm runs as a service on your computer to provide com-munication and file transfers to and from the QualiPoc units through an FTP server.NQComm periodically polls the NQView database for new configuration files orjobs and uploads the new files to an FTP server. NQComm also periodically pollsthe FTP Server for new files from the QualiPoc units and downloads the files to afolder that you specify in NQView. NQComm parses and stores status and deviceinformation from the status files in the NQView database. NQComm can also sendan SMS with the SMS service.For HTTP communication, a special HTTP service needs to run on the FTP-Server.

● FTP Server: Provides communication between NQView on your computer and theQualiPoc units, for example, to transfer job configuration and measurement files.Each QualiPoc unit has a dedicated folder on the server that NQComm, QualiPoc,or the special HTTP service can access.

● SMS Service: Provides communication between NQComm and the QualiPoc unitsfor small amounts of information. This service informs the QualiPoc unit of new fileson the FTP-Server and also transmits special commands from NQComm to Quali-Poc.

● Multimedia Server: Provides a test environment for data tests● Voice Call Server: Provides Mobile Originated Calls (MOC), Mobile Terminated

Calls (MTC) and speech quality assessment in downlink and uplink.

Overview

Page 10: Manual - QualiPoc Remote Control

InstallationSwissQual®...QualiPoc

10Manual Remote Control ─ 03

2 InstallationThe following sections describe how to install the QualiPoc software and configureQualiPoc Remote Control.

2.1 System Requirements

● Supported mobile phones: See theRelease Notes - QualiPoc Android xx.x.x.pdf document for a list ofthe supported phones.

These phones require a special firmware to run QualiPoc. If you bought your phonefrom SwissQual, this firmware is already installed, otherwise, contact our support cen-ter.Please consult the Customer Support Center.pdf document for the best methodto contact us.

● Subscriber Identity Module (SIM) card that supports the services that you want totestYou need to disable the PIN prompt of the phone.

● You require the following SwissQual Android application packages (.apk):– QualiPoc-Android-version.apk: QualiPoc android application file

– SQLookForSync-Android-version.apk (Optional): Application packagefor intrusive speech tests

– SQuad08forAndroid-release-version.apk(Optional): Applicationpackage for intrusive speech tests

– IMEI.key: License fileIf you do not have this license key file, contact our support center.

Please consult the Customer Support Center.pdf document for the best methodto contact us.

2.2 Installing and Configuring QualiPoc

This section describes how to install and configure the QualiPoc Android package onyour phone for use in Remote Control mode.

Android phones perform a multimedia scan at boot up and QualiPoc automaticallystarts 30 seconds after you turn the phone on.

System Requirements

Page 11: Manual - QualiPoc Remote Control

InstallationSwissQual®...QualiPoc

11Manual Remote Control ─ 03

To install and configure QualiPoc

1. Turn off the phone and insert the SIM card.

2. Copy the installation files to the smartphone through a Bluetooth or USB cable con-nection.

Note: If you use the USB file transfer option, for example, on the Samsung GalaxySII, disable USB debugging during the transfer, and re-enable the debugging afterthe file transfer completes.

3. In the file manager on the smartphone select theQualiPoc-Android-version.apk and follow the installation instructions.

● (Optional) Repeat this step for theSQLookForSync-Android-version.apk andSQuad08forAndroid-release-version.apk files for intrusive speechtests.

Note: If the smartphone does not have a file manager, you need to download andinstall one, for example, ES File Explorer.

4. Copy the license key file to the following location on the SD card: /QualiPoc/Settings/.

5. Configure the following access points on the smartphone:

● Disable the Auto-retrieve option for MMS ("Message" – "Multimedia Settings")● Internet access● SMS center

6. Disable the automatic date and time update feature on the smartphone, for exam-ple, touch "Settings > Date & Time > Automatic", and ensure that the automaticoption is greyed out.

7. Start QualiPoc.

Note: Do not store large amounts of multimedia content, for example, MP3s orJPGs on the smartphone as this content can prevent QualiPoc from starting prop-erly.

8. Touch the menu icon at the top of the screen and touch "Settings > Unit Config-uration > Operation Mode > Remote Control".

Installing and Configuring QualiPoc

Page 12: Manual - QualiPoc Remote Control

InstallationSwissQual®...QualiPoc

12Manual Remote Control ─ 03

Fig. 2-1: Operation mode - Remote Control mode

Note: If you want the phone to automatically start when you connect a poweredUSB cable, touch the "Autoboot" check box.If your system uses the SMS Machine service, go to step 10.

9. If your system does not use the SMS Machine service, specify the connection set-tings on the phone.

a) Touch the menu icon at the top of the screen and touch "Settings > UnitConfiguration > Select Unit Name".

b) In the "Unit Configuration" area, touch "Select unit name", type a name for thephone, and then touch "OK".

c) In the "Remote Control Connection Profile" area, touch "Select Host", type theaddress of the FTP server, and then touch "OK".

d) Touch "Select User Name", type the account name for the FTP server, andthen touch "OK".

e) Touch "Select Password", type the password for the account, and then touch"OK".

f) In NQView, update the configuration of the phone.

Installing and Configuring QualiPoc

Page 13: Manual - QualiPoc Remote Control

InstallationSwissQual®...QualiPoc

13Manual Remote Control ─ 03

g) Touch the menu icon at the top of the screen and touch "Poll Server".

Fig. 2-2: QualiPoc Remote Control mode settings

Note: The "Result Files Upload Connection Profile" is unavailable in Remote Con-trol mode since QualiPoc uploads the measurement files directly to the NQViewresults folder on the controlling PC.

2.3 Power Supply

A QualiPoc Remote Control unit must be connected to a dedicated power supply.

The power from a USB connection to a PC might not be sufficient to power the phoneduring continuous tests or tests in high speed technologies, that is, HSPA+ or LTE.

2.4 Additional Information

You can monitor the status of your QualiPoc Remote Control unit on the unit and inNQView. This section describes the relevant status icons and logs. For more detailedinformation, see the Manual - QualiPoc Android.pdf andManual - NetQual NQView.pdf documents.

2.4.1 Status Icons

The color of the title bar and the status icons at the top of the screen represents thecurrent QualiPoc Remote Control status.

● Orange Q icon: Tasks are scheduled (at least a poll server task and a mainte-nance restart task)

Power Supply

Page 14: Manual - QualiPoc Remote Control

InstallationSwissQual®...QualiPoc

14Manual Remote Control ─ 03

Fig. 2-3: Status icon and title bar of QualiPoc in idle mode with scheduled tasks

● Grey Q icon: QualiPoc is in Idle state and not running a task● Red Q icon: QualiPoc is recording a measurement file● Orange title bar: Tasks are scheduled (at least the maintenance and the next

poll). The title bar also reports the time of the next scheduled action and the overallnumber of scheduled tasks

● Red title bar: Task is running. By default, the title also contains operator and tech-nology information. Double-tap the title bar to change the information in the titlebar.

Fig. 2-4: Title bar of running task

● Grey title bar: QualiPoc application has just started and does not yet have ascheduled task. Maintenance and next poll tasks are scheduled at the end of thestartup procedure

Fig. 2-5: Title bar at startup

2.4.2 RC Log Tab

The"RC Log" tab contains important information about the current state of the systemas well as a unit overview and communications to and from the FTP server.

Additional Information

Page 15: Manual - QualiPoc Remote Control

InstallationSwissQual®...QualiPoc

15Manual Remote Control ─ 03

Fig. 2-6: RC Log

If you press the back button twice, the QualiPoc application closes. You can eithermanually restart the application or restart the phone.

Table 2-1: Description of the parameters in the RC Log

Parameter Description

Unit status Current status of the unit

Unit name Name of the unit as defined locally or as received from NQView

Subscriber SIM phone number

Next task Next task type

Scheduled tasks Number of scheduled tasks in addition to the poll and maintenance task

Last start [UTC] Timestamp of the last application start

Last reboot reason Reason of the last reboot

Last started test Test type of the last executed test

The lower part of the"RC Log" tab contains a history of the constantly changing traceevents.

2.4.2.1 Data Network Status

QualiPoc Remote Control constantly monitors the network data status and when theconnection drops, QualiPoc re-enables the "Use packet data" option on the phone.

Additional Information

Page 16: Manual - QualiPoc Remote Control

InstallationSwissQual®...QualiPoc

16Manual Remote Control ─ 03

Fig. 2-7: Data network status and Use packet data option

Additional Information

Page 17: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

17Manual Remote Control ─ 03

3 Configuring QualiPoc Remote Control Unitsin NQViewThis chapter describes how to configure your QualiPoc Remote Control units inNQView on your PC.

3.1 Creating a QualiPoc Remote Control Unit

This section describes how to add and configure a QualiPoc Remote Control unit inRemote Control mode in Diversity NQView.

To add a new QualiPoc Remote Control unit in NQView

1. In the "Control" console, create an Access Point and a subscriber profile for thephone.

a) Click "System configuration" on the Navigation panel and click the plus sign (+)beside "Subscriber and access points".

b) Click the plus sign (+) beside an operator in the tree, right-click a provider, andthen click "Add subscriber".

c) Add the subscriber information, click "Apply", and then click "OK".d) Right-click a provider and click"Add access point".e) Add the access point information, click "Apply", and then click "OK".

Note: The Access Point settings must match the Subscriber settings.

2. Create a QualiPoc Remote Control unit profile.

Creating a QualiPoc Remote Control Unit

Page 18: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

18Manual Remote Control ─ 03

a) Click "Profiles", right-click "QualiPoc unit", and then click "Add QualiPoc unitprofile".

Fig. 3-1: Add QualiPoc unit profile

Creating a QualiPoc Remote Control Unit

Page 19: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

19Manual Remote Control ─ 03

b) On the "General" tab, type a name for the unit, for example, QP RC.

Fig. 3-2: General tab in the QualiPoc unit profile dialog box

c) Specify the "Timeout" and "Poll" interval options for the unit, and click "OK".

● QualiPoc Remote Control does not support the "Data Reduction" and"Maintenance schedule" options. However, the phones do execute thehard-coded default maintenance task at 23:57 the day after the last appli-cation start.

● A QualiPoc Remote Control unit does not poll the FTP server during ameasurement task. If the "Poll interval" conflicts with the start of a measure-ment task, the poll is aborted.

3. If you want to monitor the QualiPoc Remote Control units in NQView, specify thecommunication settings on the "SMS Communication" tab.

a) Select "Send unit alerts" to receive status information.For network status information, select "Send network alerts".

b) For test results, select "Send result summaries".c) If you use the SMS machine, enter the phone number for the machine in the

"SMSC number" box.d) In the "SMCS keyword" box, enter a label for the connection.

Creating a QualiPoc Remote Control Unit

Page 20: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

20Manual Remote Control ─ 03

e) Select the communication method.

● Select "Via SMS" and click "OK".Select this option to receive result summaries in real time, otherwise theunit sends the summaries at the next poll.

● Select "Via FTP" and click "OK".

Fig. 3-3: SMS Communication

Note:● Remote Control mode does not support the other options on the "SMS commu-

nication" tab.● If you select "Via FTP" and "Via SMS", the unit sends the data via SMS when

an FTP connection is unavailable.

4. Add a QualiPoc Remote Control unit to the system hardware.

Creating a QualiPoc Remote Control Unit

Page 21: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

21Manual Remote Control ─ 03

a) Right-click "Hardware", point to "Add unit", and click "QualiPoc".

Fig. 3-4: Add QualiPoc unit

b) Type a name for the unit, for example, QP_RC_Sensation_9601.

Fig. 3-5: QualiPoc Remote Control unit

c) Type a Computer name for the unit.NQView creates a folder on the FTP server with this name. The computername can be the same as the "Name" of the unit.

d) In the "Time synchronization" list, click "NTP only", which is the only type ofsynchronization that a QualiPoc Remote Control unit supports.

e) Click the yellow asterisk (*) in front of the "Unit Profile" list, specify the parame-ters, click "Apply", and then click "OK".

f) Click the yellow asterisk (*) in front of the "NQComm control" list, specify theparameters, click "Apply", and then click "OK".

Creating a QualiPoc Remote Control Unit

Page 22: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

22Manual Remote Control ─ 03

g) Click the yellow asterisk ("*") in front of the "Unit control" list, click "FTP", spec-ify the parameters, click "Apply", and then click "OK".

h) In the "Unit" window, click "Apply", and then click "OK".

5. In the "Mobile" window, configure the settings for the phone.

a) Type the name of the mobile phone, for example, QP_RC_Sensation_9601.You can also include a custom ID, which NQView adds to the measurement filename.

Fig. 3-6: Mobile unit

b) In the "Model" list, click the type of phone that you want to use.For a list of the supported phones, see the latest QualiPoc Android ReleaseNotes.

c) In the "Subscriber" list, click the subscriber profile that you defined in step 1 forthe phone.

Creating a QualiPoc Remote Control Unit

Page 23: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

23Manual Remote Control ─ 03

d) In the "Access Point" list, click an access point for the phone.

Fig. 3-7: Internal GPS configuration

Note: The Access Point that you specify is only valid for the unit communicationbetween the mobile phone and the FTP server. QualiPoc Remote Control does notsupport the SIM multiplexer. NQView automatically adds an internal GPS to unitwhen you create the unit. Even if you disable the GPS, NQView continues toreceive GPS information when available. The option to start a Task only when avalid GPS position has been obtained is not supported

6. Specify the NQComm settings.

a) On the "File" menu, click "Settings", and then click the plus sign ("+") besideNQComm.

b) Click "Communication" and specify the communication settings for the system.

Fig. 3-8: NQComm communication settings

Creating a QualiPoc Remote Control Unit

Page 24: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

24Manual Remote Control ─ 03

c) If required, click "Servers" and specify the system time synchronization set-tings.

d) If you intend to use the SMS Machine with the QualiPoc Remote Control unit,click "SMS", and specify the details of the SMS gateway.

● Select "Enable SMS Notifications".● In the "Base URL" box, type the address for the service, for example, http://

SMSMachine/send.php.● In the "HTTP Message Variables" area, type the variables for the service,

for example, NUMBER=<UNITMOBILNR>.

Fig. 3-9: NQComm - SMS settings

3.2 Creating an Answering Station

This section describes how to create an answering station for use with QualiPocRemote Control units.

To create an answering station

1. On the Navigation panel of the "Control" console, click "System configuration".

2. Create a subscriber profile for the phone.

a) Click "System configuration" on the Navigation panel and click the plus sign (+)beside "Subscriber and access points".

b) Click the plus sign (+) beside an operator in the tree, right-click a provider, andthen click "Add subscriber".

c) Add the subscriber information, click "Apply", and then click "OK".

Creating an Answering Station

Page 25: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

25Manual Remote Control ─ 03

3. Add a unit.

a) Right-click Hardware, point to "Add unit", and then click "PC" or "QualiPoc".b) Type a "Name" and "Computer Name" for the unit.

Fig. 3-10: PC or QualiPoc unit

c) In the "Time synchronization" list, click a synchronization method, for exam-ple,"Internal sync".

d) Select the following options for the following parameters:

● "NQComm control": No connection/DTMF● "Unit control": No connection/DTMF● "Job transfer send": No connection/DTMF● "Job transfer list": No connection/DTMF● "NQComm result:" none● " Unit result": none

e) Click "Apply" and click "OK".

4. Add a device to the unit.

Creating an Answering Station

Page 26: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

26Manual Remote Control ─ 03

a) Right-click the unit in the tree, point to "Add device", and then click type ofdevice that you want to use for the answering machine, for example, "PSTN".

Fig. 3-11: PSTN settings

b) In the "Model" list, click the device model.c) In the "Subscriber" list, click the subscriber profile that you created in step 22.d) In the "Answering station" area, select the device is an answering station.e) Click "Apply" and click "OK".

3.3 Creating QualiPoc Remote Control Jobs in NQView

This section describes the types of jobs that you can create for QualiPoc Remote Con-trol units on the "Control" console of NQView as well as how create tasks and cam-paigns.

3.3.1 Battery Level and Disk Space

The following conditions prevent a measurement job from starting on the phone:● Battery level < 10%● < 150 MB of free space on SD card

The following conditions cause a running job to stop:● Battery level < 5%● < 100 MB of free space on SD card

Creating QualiPoc Remote Control Jobs in NQView

Page 27: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

27Manual Remote Control ─ 03

If the phone is connected to the charger with a USB cable, the battery might not chargefast enough to compensate for the power consumption of tests that use HS and LTEtechnologies. In such a scenario, the phone can suddenly turn off when the batterylevel drops below 5% despite being connected to a charger.You can view low battery and low disk space alert messages on the "Alerts andActions" tab in NQView . You can also find information about task failed starts and run-ning task aborts on the "Log messages" and "System log" tabs.

Fig. 3-12: Alerts and actions tab in NQView

3.3.2 Adding a Call Job

This section describes how to add a call job for a QualiPoc Remote Control unit as wellas the supported job types.

3.3.2.1 Adding a Call to Any Number Job

QualiPoc Remote Control only supports one Call to Any Number test for each Call toAny Number job.

To create a Call to Any Number job

1. On the Navigation panel of the Control console, click "Tasks and Jobs".

Creating QualiPoc Remote Control Jobs in NQView

Page 28: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

28Manual Remote Control ─ 03

2. Expand "Job Definitions" in the tree, right-click "Call to any number", and then click"Add job".

Fig. 3-13: Call to any number job settings

3. Type a name for the job and specify the following supported parameters:

● "Minimum" in the "Pause between cycles" area● "Max connection timeout", that is, maximum call setup time in the"Connect fail-

ure behavior" area

4. Click "Apply" and click "OK".

5. In the "Call to any number test" window, specify the duration of the call, and thentype the number to call.

Fig. 3-14: Call to any number test settings

Note: If a call drops or fails after the pause, QualiPoc sets up a new call.

Creating QualiPoc Remote Control Jobs in NQView

Page 29: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

29Manual Remote Control ─ 03

6. Click "Apply" and then click "OK".

3.3.2.2 Adding a Speech Double Ended Job

QualiPoc in QualiPoc Remote Control mode supports the following Speech DoubleEnded scenarios:

● QualiPoc Remote Control unit to QualiPoc Remote Control unit● QualiPoc Remote Control unit to a Diversity Voice Call Server: You can only use

the QualiPoc Remote Control unit as the A-side in this scenario

The following procedure assumes that you have already configured a Diversity VoiceCall Server.

To define the measurement task in NQView

1. On the Navigation panel of the "Control" console, click "Tasks and Jobs", right-click"Tasks", and then click "Add tasks".

2. Type a name for the task.

Fig. 3-15: Add a measurement task

3. In the "Device A/B side" area, select the A-side and B-side devices.

a) In the A-side list on the left, click a QualiPoc Remote Control unit.b) In the B-side list on the right, click a QualiPoc Remote Control unit.

Note: You can also click a Diversity Voice Call Server in the B-side list.

4. Add a measurement job to the task.

Creating QualiPoc Remote Control Jobs in NQView

Page 30: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

30Manual Remote Control ─ 03

a) In the "Job sequence" area, click the green plus sign ( ).b) Click the yellow asterisk ( ) in front of the Job list, and then click "Intrusive

job".

Fig. 3-16: Add an intrusive job to the measurement task

c) In the "Name" box, type a name for the job in the following DTMF job transferformat:

● job_xyzd) In the "Record hang-over [ms]" box, type a value (minimum 6000).e) In the "MOC:MTC ratio" box, specify the call direction, for example, 1:1.

QualiPoc Remote Control only supports the 1:0, 0:1, or 1:1 MOC:MTC ratiosfor Speech Double Ended jobs.

f) In the "Timings" area, select "Use call duration to abort call".If you do not enable this option, the measurement task will not run correctly

g) Specify the remaining timings, click "Apply", and then click "OK".

5. In the"Intrusive test" window, specify the settings for the speech test.

a) Type a name for the test.

Creating QualiPoc Remote Control Jobs in NQView

Page 31: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

31Manual Remote Control ─ 03

b) In the "Test type" list, click one of the following types:

● "Speech"● "Speech POLQA"● "Speech-Wideband"● "Speech-Wideband POLQA"

c) In the "Direction" area, click a direction for the reference sample.The sample direction must be A to B only, B to A only, or alternating. Sampleswith alternating directions must start with a B to A direction. NQView does notaccept the configuration on the task level if you try to set the sample directionin different ways.

d) In the "Reference sample" list, click the speech sample that you want to useEach test in the job must use the same speech sample.

e) In the "Save WAV" files area, click an option.f) Click "Apply" and then click "OK".

Fig. 3-17: Add a speech test to the intrusive job

6. In the "Job details" in task window, click "Save".

7. In the "Measurement task" window, specify the "Duration" and the number of"Cycles" for the task.

8. Click "Apply", and then click "OK".

3.3.3 Creating a Data Job

This section describes how to create a data job for a QualiPoc Remote Control unit aswell as the supported job types.

To create a data job

1. On the Navigation panel of the "Control" console, click "Tasks and Jobs".

2. Expand "Job Definitions" in the tree, right-click "Data", and then click "Add job".

3. Type a name for the job.

Creating QualiPoc Remote Control Jobs in NQView

Page 32: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

32Manual Remote Control ─ 03

Fig. 3-18: Data job

4. Specify the following supported parameters:

● "Minimum" in the "Pause between cycles" area● "Max connection timeout", that is, maximum data connection setup time, in the

"Connect failure behavior" area

5. Click "Apply" and then click "OK".

6. In the "Data test" window, type a name for the test.

7. In the "Test type" list, click one of the following types:

● "Capacity": Can retrieve up to 4 links● "FTP": Get or Put action with a fixed or maximum duration● "HTTP Transfer": Get or Put action with a fixed or maximum duration● "HTTP Browser"● "Ping"● "Email"● "MMS"● "SMS"

Creating QualiPoc Remote Control Jobs in NQView

Page 33: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

33Manual Remote Control ─ 03

Fig. 3-19: Data test settings

Note: You can add several data tests to a data job; however, you can only includeone MMS or one SMS send or receive test in one data job. For more informationon the test types, see the following sections.

8. Create a task for the job.

For more information, see chapter 3.4, "Defining a Task", on page 49.

3.3.3.1 Data Job Test Types

This section describes the types of tests that you can configure for QualiPoc RemoteControl units in NQView.

Capacity Test

This section describes the parameters of the Capacity data test.

Creating QualiPoc Remote Control Jobs in NQView

Page 34: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

34Manual Remote Control ─ 03

Fig. 3-20: Capacity data test

Parameter Description

"Name" Type a name for the test.

"Decision profile" Not supported

"Test type" Select "Capacity"

"Max duration" Specifies the timeout for the test

"Use as fixed duration" Enables fixed duration tests to evaluate dedicated KPIs. If the test ends beforethe fixed duration elapses, the test is set as failed. For best results, use large files

"Pause duration" Specifies the amount of time to wait after a test completes before the next teststarts. QualiPoc Remote Control does not support the random option.

"Operation (Get Only)" Set the test direction

Get URLs The Capacity test can run up to 4 HTTP Transfer Get tests in parallel. Type thecomplete URL, including the path and the filename to download, and then pressENTER to add the next URL

"Put URLs", "Local file", "User agent", "Buffersize", "Time window", and "Byte threshold"

Not supported

Email Receive Test

This section describes the parameters of the Email receive data test.

Creating QualiPoc Remote Control Jobs in NQView

Page 35: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

35Manual Remote Control ─ 03

Fig. 3-21: Email receive data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "Email Receive"

"Max duration" Specifies the timeout for the test

"Pause duration" Specifies the amount of time to wait after a test completes before the next teststarts. QualiPoc Remote Control does not support the random option.

"Server" Type the address of the POP3 or IMAP server name.

"Subject" Type the subject of the email

"Username" and "Password" Type the "Username" and "Password" of the POP or IMAP server

"Protocol" Specifies the email protocol that you want to use, that is, POP3 and IMAP

"Mode" Sets the action to perform upon receipt of the email, that is, "Delete message","Delete all messages in inbox", or "Leave message".

"Security" Secure connections TLS/SSL are only supported if the SMTP mail server sup-ports STARTTLS. When you select this option, you need to include the portnumber at the end of the server address. See table 3-1 for the port numbersthat you can use.

Table 3-1: Port numbers for Email receive and send tests

Test Protocol Use SSL Standard Port Example

Email send SMTP No 25 mail.gmx.com

Email send SMTP with TSL Yes 587 smtp.gmail.com

Email send SMTP with SSL Yes 465 smtp.gmail.com

Creating QualiPoc Remote Control Jobs in NQView

Page 36: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

36Manual Remote Control ─ 03

Test Protocol Use SSL Standard Port Example

Email receive POP3 No 110 pop.gmx.com

Email receive IMAP4 No 143 imap.gmx.com

Email receive POP3 with SSL Yes 995 pop.gmail.com

Email receive IMAP4 with SSL Yes 993 imap.gmail.com

Email Send Test

This section describes the parameters of the Email send data test.

Fig. 3-22: Email send data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "Email Send"

"Max duration" Specifies the timeout for the test

"Pause duration" Specifies the amount of time to wait after a test completes before the next test starts. QualiPocRemote Control does not support the random option.

"SMTP server" Type the address of the SMTP server name.

"Email address" Type the email address of the recipient

"Subject" Type the subject of the email

Creating QualiPoc Remote Control Jobs in NQView

Page 37: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

37Manual Remote Control ─ 03

Parameter Description

"Attachment" If required, click an attachment file in the list.

The file must be on the same PC as the NQView installation and in the reference\Upload\Datafolder of the QualiPoc Remote Control unit.

"Text size" Amount of text to include in the body of the email.

"Authentication" If the SMTP server requires authentication, select "Use SMTP authentication", and then type the"Username" and "Password" for the account on the server.

"Security" Secure connections TLS/SSL are only supported if the SMTP mail server supports STARTTLS.When you select this option, you need to include the port number at the end of the server address.See table 3-1 for the port numbers that you can use.

FTP Test

This section describes the parameters of the FTP data test.

Fig. 3-23: FTP data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "FTP"

"Max duration" Specifies the timeout for the test

"Use as fixed duration" Enables fixed duration tests to evaluate dedicated KPIs. If the test ends before the fixed durationelapses, the test is set as failed.

"Pause duration" Specifies the amount of time to wait after a test completes before the next test starts. QualiPocRemote Control does not support the random option.

Creating QualiPoc Remote Control Jobs in NQView

Page 38: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

38Manual Remote Control ─ 03

Parameter Description

"Host" Type the address of the FTP server

"Operation" Set the test direction, that is, "Get" or "Put"

"Mode" Specify the FTP server mode, that is, "Active" or "Passive".

"Local file (Put Only)" Select the file to be uploaded during an "FTP Put" test.

The file must be on the same machine as the NQView installation and in thereference\Upload\Data folder of the QualiPoc Remote Control unit.

"Remote file" ● For Put tests, type the name of the file that will be written to the FTP server● For Get tests, type the name of the remote file to be downloaded

"Username" and "Password" Type the username and password for the FTP account.

"Buffer size", "Time window",and "Byte threshold"

Not supported

FTP Over SSL

FTP tests support FTP over SSL, that is, host addresses that start with FTPS andFTPES.

► To use FTPS or FTPES, use the following formats for the host address when youconfigure the test:

● ftps://ip_host_address● ftpes://ip_host_address

Fig. 3-24: FTP over SSL address in Data test dialog box in NQView

Creating QualiPoc Remote Control Jobs in NQView

Page 39: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

39Manual Remote Control ─ 03

Note: The default command port number for FTPS is 990 and for FTPES is 21. Touse a different command port number, add the a colon (:) and the number to theend of the address, for example, ftps://80.74.152.241:992, where 992 isthe custom port number.

HTTP Browser Test

This section describes the parameters of the HTTP Browser data test.

Fig. 3-25: HTTP browser data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "HTTP Browser"

"Max duration" Specifies the timeout for the test

"Pause duration" Specifies the amount of time to wait after a test completes before the next test starts. QualiPocRemote Control does not support the random option.

"Remote File" If needed, an element in the web page can be downloaded

"User agent", "Proxy", and"Proxy port"

Not supported

HTTP Transfer Test

This section describes the parameters of the HTTP Transfer data test.

Creating QualiPoc Remote Control Jobs in NQView

Page 40: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

40Manual Remote Control ─ 03

Fig. 3-26: HTTP transfer data test

Parameter Description

"Name" Type the name of the test

"Decision profile" Not supported

"Test type" Select "HTTP Transfer"

"Max Duration" Specifies the timeout for the test

"Use as Fixed Duration" Enables fixed duration tests to evaluate dedicated KPIs. If the test ends before the fixed durationelapses, the test is set as failed.

"Pause Duration" Specifies the amount of time to wait after a test completes before the next test starts. QualiPocRemote Control does not support the random option.

"Operation" Sets the test direction, that is, "Get" or "Put"

"Randomized with" Not supported

"URL" ● For Get tests, type the complete URL, that is, the path and the filename to download.● For Put tests you might need to include the username and the password for the HTTP server

where you the file is put

"Local file (Put Only)" Select the file to be uploaded during an "HTTP Transfer" test.

The file must be on the same machine as the NQView installation and in thereference\Upload\Data folder of the QualiPoc Remote Control unit.

"User agent", "Buffer size","Time window", and "Bytethreshold"

Not supported

Creating QualiPoc Remote Control Jobs in NQView

Page 41: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

41Manual Remote Control ─ 03

MMS Receive Test

This section describes the parameters of the MMS Receive data test.

Fig. 3-27: MMS Receive data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "MMS receive"

You can only perform single-sided MMS receive tests.

"Max duration" Specifies the timeout for the test

"Pause duration" Not supported

"Protocol" and "User agent" Not supported

The test uses the MMS APN that you define on the phone.

The subject of the MMS must have the following format:

● SQMMS$XXXX$DDMMYYhhmm$IMEI$MMS_tex

Where:

● XXXX: Number of message● DDMMYY: Day, month, and year● hhmm: hour, and minutes● IMEI: Sender IMEI● MMS_text: Text of the message

MMS Send Test

This section describes the parameters of the MMS Send data test.

Creating QualiPoc Remote Control Jobs in NQView

Page 42: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

42Manual Remote Control ─ 03

Fig. 3-28: MMS Send data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "MMS send"

"Max duration" Specifies the timeout for the test

"Pause duration" Specifies the amount of time to wait after a test completes before the next test starts. QualiPocRemote Control does not support the random option.

"Number" For single-sided tests only

"Double sided" Select this option if the send and the receive party are defined in the task.

"Picture" Select the image to transfer with the MMS.

The file must be on the same machine as the NQView installation and in thereference\Upload\Data folder of the QualiPoc Remote Control unit.

"Protocol" and "Useragent"

Not supported

The test uses the MMS APN that you specify on the phone.

Ping Test

This section describes the parameters of the Ping data test.

Creating QualiPoc Remote Control Jobs in NQView

Page 43: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

43Manual Remote Control ─ 03

Fig. 3-29: Ping data test

Parameter Description

"Name" Type a name for the test

"Decision Profile" Not supported

"Test type" Select "Ping"

"Max Duration" Specifies the timeout for the test.

"Pause Duration" Specifies the amount of time to wait after a test completes before the next test starts. QualiPocRemote Control does not support the random option.

"Host" Type the address of the host that you want to ping.

"Number of Pings" Specify the number of pings

"Interval" Specify the amount of time to wait upon receipt of the ping echo, if received, and the next ping.

"Packet Size" Specify the size of the packet in bytes.

"Timeout" Echo replay timeout

SMS Receive Test

This section describes the parameters of the SMS Receive data test.

At the begininng of the test, QualiPoc deletes the contents of the inbox.If a QualiPoc Remote Control device receives an SMS Send test that has the samesubcription number as the destination number, QualiPoc Remote Control automaticallyenables the "Back to sender" option.

Creating QualiPoc Remote Control Jobs in NQView

Page 44: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

44Manual Remote Control ─ 03

Fig. 3-30: SMS Receive data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "SMS receive"

You can only perform single-sided SMS receive tests.

"Max duration" Specifies the timeout for the test.

"Pause duration" Not supported

"Service preference" Not supported

The test uses the SMS message center that you specify on thephone.

The subject of the SMS must have the following format:

● SQMMS$XXXX$DDMMYYhhmm$IMEI$SMS_text

Where:

● XXXX: Number of message● DDMMYY: Day, month, and year● hhmm: hour, and minutes● IMEI: Sender IME● SMS_text: Text of the message

SMS Send Test

This section describes the parameters of the SMS Send data test.

At the begininng of the test, QualiPoc deletes all of the text messages in the inbox.If a QualiPoc Remote Control device receives an SMS Send test that has the samesubcription number as the destination number, QualiPoc Remote Control automaticallyenables the "Back to sender" option.

Creating QualiPoc Remote Control Jobs in NQView

Page 45: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

45Manual Remote Control ─ 03

Fig. 3-31: SMS send data test

Parameter Description

"Name" Type a name for the test

"Decision profile" Not supported

"Test type" Select "SMS send"

"Max duration" Specifies the timeout for the test.

"Pause duration" Specifies the amount of time to wait after a test completes before the next test starts. Quali-Poc Remote Control does not support the random option.

"Service preference" Not supported

The test uses the SMS message center that you specify on the phone.

"Number" For single-sided tests only

"Operation" ● " Double sided": Select this option if the send and the receive party are defined in thetask

● "Single-sided"● "Back to sender": Not supported

"SMS length" Specifies the number of characters in the SMS

"Use custom text and Custom text" Type the text for the SMS, otherwise a default text is used

If a QualiPoc Remote Control device receives an SMS Send test that has the samesubscription number as the destination number, QualiPoc Remote Control automati-cally enables the "Back to sender" option.

3.3.4 Adding an Idle Job

This section describes how to add an Idle job for a QualiPoc Remote Control unit.

Creating QualiPoc Remote Control Jobs in NQView

Page 46: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

46Manual Remote Control ─ 03

To create an Idle job

1. On the Navigation panel of the "Control" console, click "Tasks and Jobs".

2. Expand "Job Definitions" in the tree, right-click "Idle", and then click "Add job".

Fig. 3-32: Idle job

3. Type a name for the job.

4. In the "Pause between cycles" area, specify the length of the pause in the "Mini-mum" box.

5. Click "Apply" and click "OK".

6. In the Idle test window, click "Apply", and then click "OK".

Fig. 3-33: Idle test

Note: QualiPoc Remote Control does not support the "Maximum file size" option.

7. Create a task for the job.For more information, see chapter 3.4, "Defining a Task", on page 49.

3.3.5 Adding an Intrusive Job

This section describes how to add an Intrusive job for a QualiPoc Remote Control unit.

Creating QualiPoc Remote Control Jobs in NQView

Page 47: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

47Manual Remote Control ─ 03

To create an intrusive job

1. On the Navigation panel of the "Control" console, click "Tasks and Jobs".

2. Expand "Jobs" in the tree, right-click "Intrusive", and then click "Add job".

3. Type a name for the job.

Fig. 3-34: Intrusive job

4. Specify the following parameters.

● "Test sequence repetition"● "Record hang-over"

Note: For a call to an answering station, the Record hang-over must be 18500. Formore information on how to configure an answering station, see chapter 3.2, "Cre-ating an Answering Station", on page 24.

5. Specify the following timing settings:

● "Call duration"● "No call setup time"● "MOC:MTC": The value must be 1:0

Creating QualiPoc Remote Control Jobs in NQView

Page 48: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

48Manual Remote Control ─ 03

6. In the "Intrusive test" window, specify the parameters for the test.

a) Type a name for the test.b) In the "Test type" list, click "Speech" or "Speech POLQA".

QualiPoc Remote Control only supports these test types.c) In the "Direction" area, click "B to A".

QualiPoc Remote Control does not support the "A to B" option.d) In the "Reference sample" list, click an audio file.e) In the "Save WAV files" area, click an option.f) Click "Apply" and then click "OK".

7. Create a task for the job.For more information, see chapter 3.4, "Defining a Task", on page 49

3.3.6 Adding an Upload Job

This section describes how to create an upload job and task to schedule when NQViewuploads the measurement files to the QualiPoc Remote Control unit.

When you specify an upload schedule, the following upload events occur:

● On QualiPoc startup: Measurement files, QPCLog files, and crash-dumps areuploaded

● On poll: If present, QPCLog files are uploaded● After task: If present, QPCLog files are uploaded● On scheduled upload: Only measurement files are uploaded

If you do not create an upload job, the following upload events occur:

● On QualiPoc startup: Measurement files, QPCLog files, and crash-dumps areuploaded

● On poll: If present, QPCLog files and measurement files are uploaded● After task: If present, QPCLog files and measurement files are uploaded

To create an upload job

1. On the Navigation panel of the "Control" console, click "Tasks and Jobs".

Creating QualiPoc Remote Control Jobs in NQView

Page 49: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

49Manual Remote Control ─ 03

2. Expand "Job Definitions" in the tree, right-click "Upload", and then click "Add job".

3. In the "Job" window, type a name for the job, and then click "OK".

Fig. 3-35: Create an Upload job

4. In the "Upload test" window, ensure that the "Upload profile" is set to none, andthen click "OK".

Fig. 3-36: Create Upload test

5. Create a task for the job.For more information, see chapter 3.4, "Defining a Task", on page 49.You need to specify a task duration that is long enough for the upload to complete.

3.4 Defining a Task

The following steps describe how to create a measurement task for QualiPoc RemoteControl. The parameters that are not included in the steps are not supported by Quali-Poc Remote Control.

A task is a collection of jobs that you can assign to one or two devices depending onthe job type.

To define a task for QualiPoc Remote Control

1. On the Navigation panel, click "Tasks and Jobs", right-click "Tasks", and then click"Add task".

Defining a Task

Page 50: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

50Manual Remote Control ─ 03

2. In the "Device A/B side" area, select the device for the task.

Note: An A B-side device is required for Intrusive jobs as well as double-sidedMMS and SMS jobs.

3. Add a job to the task.

a) In the "Job sequence" area, click the green plus sign .b) In the list of jobs, click a job.

c) For data and messaging jobs, click an access point in the list.

Note: Only data tasks can use the access point profile that you select in NQView.For MMS and SMS tasks, NQView only uses this access point to validate the task.Instead, these tasks use the access point and subscriber information that isdefined on the phone.

4. Specify the type of Job execution.

● "Best effort": Executes a job and then starts the next job● "Multi-RAB": Simultaneously or randomly executes a data job and a voice job

Defining a Task

Page 51: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

51Manual Remote Control ─ 03

5. Specify the "Duration" and the number of "Cycles" for the task.The task stops when all of the cycles have been executed or the duration has beenreached.

6. (Optional) In the "Forcing A/B" area, specify the technology forcing options for thetask.

Note: QualiPoc Remote Control supports forcing on all GSM, WCDMA, and LTEbands. However, GSM Preferred, WCDMA Preferred, LTE Preferred, ARFCN, andUARFCN forcing are not supported.

7. (Optional) Select a default Data recording profile.

Note: QualiPoc Remote Control only supports the "PCAP files per measurement"or "PCAP file per session" profiles.

8. Specify the schedule for the task.

a) Click the yellow asterisk beside the Time trigger list.b) Type a name for the trigger.c) Configure the scheduling options, click"Apply", and then click "OK".

Fig. 3-37: Trigger profile

9. If you want to deactivate PDP before the task runs, select the "Force context deac-tivation" check box.

Note:● Voice tasks: QualiPoc executes PS deactivation at the start of a task and acti-

vates PS at end of the task

Idle Call Call Idle

PS attachPS detachTask

Idle

Fig. 3-38: PS activation in voice tasks

● Single Data, Multiple Data, and Video tasks: QualiPoc deactivates PDP andreactivates PDP when the task starts and for each session

Defining a Task

Page 52: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

52Manual Remote Control ─ 03

Data Data Idle

PS attachPS detach

TaskIdleDataIdle

PS detachPS detachPS attach

PS attach PS detachPS attach

Fig. 3-39: PS activation in single data, multiple data, and video tasks

● Multi-RAB: Same as data tasks except that the detach occurs immediately afterthe data job completes and not at the end of a session

10. Click "Apply" and click "OK".

3.5 Defining a Campaign

A measurement campaign is a collection of tasks that allows you to start the taskssimultaneously. You cannot assign a task to more than one campaign.

To define a measurement campaign for QualiPoc Remote Control

1. On the Navigation panel, click "Task and Jobs", right-click "Campaigns", and thenclick "Add campaign".

2. Type a name for the campaign in the "Name (ID)" box.

Fig. 3-40: Creating a campaign

3. In the"Execution type" list, click "Asynchronous campaign".

Note: QualiPoc Remote Control only supports asynchronous campaigns.

4. Drag the tasks that you want to add to the campaign from the list of "Availabletasks" on the right to the "Tasks in campaign" list on the left.

5. Click "Apply" and then click "OK".

Defining a Campaign

Page 53: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

53Manual Remote Control ─ 03

3.6 Monitoring Tasks

This section describes the available actions and information that you can access inNQView when you run tasks on a QualiPoc Remote Control unit.

3.6.1 Available Commands

You can access the following commands when you right-click a QualiPoc Remote Con-trol unit during the operation of the probe.

Fig. 3-41: Available NQView commands for a QualiPoc Remote Control unit

Action Description

"Edit" Check and modify the configuration of the device

"Add device" Adds a mobile device to the unit. You can only add one mobile device to a QualiPoc RemoteControl unit

"Update configuration" Sends the new configuration to the unit

"Export configuration" Not supported

"Get log files" Uploads command to FTP server, sends a poll SMS to the unit, which then sends the log files toNQView. If SMS is not enabled on the unit, the command is sent at the next scheduled poll.

Monitoring Tasks

Page 54: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

54Manual Remote Control ─ 03

Action Description

"Poll" Sends a poll SMS to the unit

Only available if you use an SMS service.

"Reboot hardware (delete tasks)" Sends a reboot SMS to the unit. After the reboot, all of the scheduled tasks are deleted.

"Reboot hardware (keep tasks)" Sends a reboot SMS to the unit. After the reboot, the scheduled tasks are preserved.

"Update position" Allows you to manually specify the position of the unit, for example, if the unit is indoors andGPS coordinates are not available.

"Show position in Google Earth" Requires a Google Earth installation on the PC to show the last available position of the unit.

To refresh the unit position, you need to exit Google Earth and click the "Show position in Goo-gle Earth" command again.

"Update unit events" Updates the events on the unit.

"Copy" and "Delete" Duplicates or deletes the unit from the configuration.

3.6.2 Unit Status

Status Description

"Ready" Unit is correctly configured and is ready to start.

"Time not synchronized" Time synchronization with the NTP server failed. The unit continues to run scheduled tasks, butcannot start a new task.

"Connected" NQComm has connected to the FTP server, but has not received information from the unit.

"Starting" QualiPoc is starting, typically after receiving the first unit configuration or after a reboot.

"Shutdown" QualiPoc is shutting down, typically after receiving a reboot command or when performing thescheduled maintenance application restart.

"GPS not ready" Appears shortly after the first configuration is sent to the unit.

A valid GPS position is not a requirement to start a task.

"Measuring (on Mobile level)" Unit is running a test.

"Timeout 1" Communication has not been received from the unit for more than the amount of time that isspecified by the "Timeout1" parameter in the "QualiPoc unit" profile.

"Timeout 2" Communication has not been received from the unit for more than the amount of time that isspecified by the "Timeout2" parameter in the "QualiPoc unit" profile.

"Unit not ready / Not connec-ted"

Unit has not been configured, NQComm is not running, or the unit is not ready on the mobilelevel.

3.6.3 Workspace Tabs

This section describes the information that appears on the various tabs in the Work-space area when you click the QualiPoc Remote Control unit on the Navigation panel.

Monitoring Tasks

Page 55: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

55Manual Remote Control ─ 03

3.6.3.1 General Tab

The "General" tab contains, when available, serving cell and position information forthe selected unit.

Fig. 3-42: General Tab

When the unit is idle, the "Network value" might appear as "Unknown".

3.6.3.2 Communication Tab

The "Communication" tab contains the following information.

Fig. 3-43: Communication Tab

Parameter Description

"Last start" Date and time of the most recent operation of the unit

"Last reboot reason" Description of why the last reboot occurred. This information also appears as the first row of the logfiles for the unit.

"Last contact" Date and time of last poll to the FTP server

Monitoring Tasks

Page 56: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

56Manual Remote Control ─ 03

Parameter Description

"Last meas file" Date and time that the last measurement file was received.

"# meas files / 24 h" Number and total size of the measurement files that have been received in the last 24 hours

"# log files / 24 h" Number and total size of the log files that have been received in the last 24 hours

"Scheduled tasks" Number of tasks that have been scheduled on the unit as reported by the unit

3.6.3.3 Data Upload Tab

The "Data Upload" tab is not available for QualiPoc Remote Control.

3.6.3.4 Alerts and Action Tab

The "Alerts and Action" tab is not available for QualiPoc Remote Control.

3.6.3.5 Tasks Tab

The "Tasks" tab contains a list of the tasks that are running on the unit. The informationin this list is from NQView.

Fig. 3-44: Tasks tab in NQView System Configuration Workspace

Monitoring Tasks

Page 57: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

57Manual Remote Control ─ 03

Fig. 3-45: Tasks tab in NQView Tasks and Jobs Workspace

3.6.3.6 Version Info Tab

The "Version info" tab contains information about the QualiPoc software and firmwareon the unit.

Fig. 3-46: Version info tab

3.7 Remotely Updating SwissQual Software

This section describes how to use NQView to remotely update the QualiPoc softwareon your phone.

► To prepare the QualiPoc software update, add one or more of the following files toa zip file with the name SWUpdate-QP-Android*.zip on the controlling PC.

● QualiPoc - Android - XX.X.X.XX.apk

Remotely Updating SwissQual Software

Page 58: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

58Manual Remote Control ─ 03

● SQuad08-ForAndroid-XX.X.X.XX.apk● SQLookForSynch - Android- XX.X.X.XX.apk● License key

Note: The package can only contain these files. You can name the update pack-age SWUpdate-QP-Android.zip or SWUpdate-QP-Android-12.1.1.zip. NQViewdoes not recognize SWUpdate-QP.zip as a valid update file. If Remote Controlmode is not enabled in the license key, the unit is lost after the update.

To update SwissQual software remotely from NQView

1. On the "Control" console, click "System configuration".

2. In the tree, click the plus sign (+) beside "Profiles".

3. Right-click "Software update" and click "Add software update".

Fig. 3-47: Add software update profile

4. Select the zip software update package for the unit.

a) In the "Unit software update" window, click the browse button (...) and locatethe update file.

Remotely Updating SwissQual Software

Page 59: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

59Manual Remote Control ─ 03

b) Click "Apply" and click "OK".

Fig. 3-48: Locate the update file

5. Update the measurement units.

a) Right-click the software update profile in the tree, and then click "Executeupdate".

Fig. 3-49: Execute update

Remotely Updating SwissQual Software

Page 60: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

60Manual Remote Control ─ 03

b) In the list, click the units that you want to update, and then click "Executeupdate".

Fig. 3-50: Select QualiPoc Remote Control unit to update

Note: During the QualiPoc update, NQView uploads the update package to theFTP server and sends an SMS to the QualiPoc Remote Control unit. If the unitdoes not use an SMS service, the update occurs at the next poll. The QualiPocRemote Control unit downloads, verifies the update package from the FTP server,and runs the update.

3.7.1 Monitoring the Update

You can monitor the update process on the "Alerts and actions" tab of theNQView log.

If the update package contains a combination of theSQuad08-ForAndroid-XX.X.X.XX.apk,SQLookForSynch - Android- XX.X.X.XX.apk, or license files, NQView updatesthe logs status to "Succeeded" when the update is complete.

If the update package also contains the QualiPoc - Android - XX.X.X.XX.apkfile, NQView updates the log status to "Succeeded" after the QualiPoc Remote Controlunit restarts.

If the update package contains more than one file, theQualiPoc - Android - XX.X.X.XX.apk update always runs last.

If the update package contains files that are not compatible with QualiPoc, for exam-ple, a *.dll file, the update extracts the compatible files and sends a "FailedNQView".

If the license has expired, a "Please update the license" message appears in the log.

Remotely Updating SwissQual Software

Page 61: Manual - QualiPoc Remote Control

Configuring QualiPoc Remote Control Units in NQViewSwissQual®...QualiPoc

61Manual Remote Control ─ 03

Fig. 3-51: Monitoring the software update

Remotely Updating SwissQual Software

Page 62: Manual - QualiPoc Remote Control

QualiPoc Remote Control Operation on a Mobile PhoneSwissQual®...QualiPoc

62Manual Remote Control ─ 03

4 QualiPoc Remote Control Operation on aMobile PhoneThis chapter describes how QualiPoc operates in Remote Control mode.

4.1 Remote Configuration

In Remote Control mode, you configure the QualiPoc Remote Control unit remotelywith NQView.

In addition to the communication settings and the QualiPoc Remote Control configura-tion, you can also perform the following tasks with NQView:● Force a phone reboot● Define behaviour of measurements, that is, task scheduling

NQView saves the configuration settings for the QualiPoc Remote Control unit to aZIP file that uses the following naming convention:

ConfigUpdate_yyyymmdd-hhmmss.zip.

The NQComm service uploads this file to the FTP server and informs QualiPocRemote Control about the new file. QualiPoc Remote Control then downloads the fileto the phone and informs NQView whether the new configuration was loaded success-fully or not.

4.1.1 Rebooting a Phone Remotely

A maintenance hard-coded application restart is scheduled to take place at 23:57:00on the day after the last QualiPoc application start.

The following reboot options are also available in NQView:● "Reboot hardware (delete tasks)": Aborts the scheduled jobs and reboots the

phone● "Reboot hardware (keep tasks)": Reboots the phone without stopping and deleting

the scheduled jobs

4.2 Measurement Jobs

This section describes how QualiPoc Remote Control handles the measurement jobsthat you configure in NQView. For information on how to create and schedule QualiPocjobs, see the Manual - Diversity NQView.pdf document.

Remote Configuration

Page 63: Manual - QualiPoc Remote Control

QualiPoc Remote Control Operation on a Mobile PhoneSwissQual®...QualiPoc

63Manual Remote Control ─ 03

4.2.1 Scheduling Measurements

The following steps occur after you start a QualiPoc Remote Control campaign (a col-lection of tasks):

1. NQComm uploads the measurement configuration files from NQView to the dedi-cated folder for the QualiPoc Remote Control unit on the FTP-Server and informsQualiPoc about the new file either by SMS or the next time that the phone polls theFTP server.

2. QualiPoc receives the information about the new measurement, connects to theFTP server, downloads the configuration file to the phone, and then analyzes thefile.

Note: If QualiPoc Remote Control does not receive the new measurement configu-ration message or if a GPRS connection is not possible, the unit status remainsidle.

3. If the phone has the correct license for the job, QualiPoc Remote Control sched-ules, and executes the measurement.

4. NQComm verifies that QualiPoc Remote Control successfully loaded the measure-ment configuration file on the phone.If the measurement task is two sided, the B-side job is scheduled first; once theunit confirms that B-side job has been loaded, the A-side job will be scheduled.

5. After the tasks in a campaign successfully load, the task status changes to “run-ning” in NQView.When the task is running on the QualiPoc Remote Control unit the title bar and theQ icon turns red.

Note: Depending on the network, this process can take several minutes.

4.2.2 Running Measurements

QualiPoc Remote Control schedules a measurement after receiving the job informationfrom NQView. After the measurement completes, QualiPoc Remote Control calculatesthe start time for the next measurement and displays the time in the title bar.

● In QualiPoc Remote Control measurement execution is the same as in QualiPocHandheld mode. For more information, see theManual - QualiPoc Android.pdf document.

● A low battery level on the phone as well as a low amount of free space on the SDcard can stop a running job. For more information, see chapter 3.3.1, "BatteryLevel and Disk Space", on page 26.

Measurement Jobs

Page 64: Manual - QualiPoc Remote Control

QualiPoc Remote Control Operation on a Mobile PhoneSwissQual®...QualiPoc

64Manual Remote Control ─ 03

Fig. 4-1: RC Log tab

4.2.3 Post-Measurement Actions

After a measurement, QualiPoc Remote Control automatically uploads the measure-ment results file to the folder for the unit on the FTP server. The NQComm service onthe PC downloads the file to the measurement folder that you specify in the NQViewsettings.

4.2.3.1 Manually Uploading Measurement Files

QualiPoc Remote Control also provides you with the option to manually upload themeasurement files from your device.

► To manually upload measurement files from the device, touch the menu icon atthe top of the screen and tap "Upload".

Fig. 4-2: Manually upload a measurement file

Measurement Jobs

Page 65: Manual - QualiPoc Remote Control

QualiPoc Remote Control Operation on a Mobile PhoneSwissQual®...QualiPoc

65Manual Remote Control ─ 03

4.2.3.2 Upload Behaviour

The following figure describes the QualiPoc Remote Control upload options for mea-surement files.

Fig. 4-3: Upload behaviour

4.3 QualiPoc Remote Control Unit Information

Each time a QualiPoc Remote Control unit connects to the FTP server, QualiPocRemote Control uploads a file with device information that you can view in NQView aswell as file with status information.

4.3.1 Log File

QualiPoc Remote Control records the activities of the unit in log files and regularlyuploads the files to the controlling PC in the \Logfiles\UnitName subfolder of thefolder that contains the measurement files.

You can analyse the log file and the measurement files to troubleshoot problems thatmight arise during a measurement campaign. The name of the log file contains thename of the unit, a sequential number, and the timestamp of the last QualiPoc RemoteControl start-up time, for example, UnitName-0123-QPCLog200606201557.txt.

The log file tends to be unreadable in Notepad. Use an advanced text editor, such asNotepad++ to open the file.

QualiPoc Remote Control Unit Information

Page 66: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

66Manual Remote Control ─ 03

5 QualiPoc Remote Control ShellThe following sections describe the hardware components of the QualiPoc RemoteControl Shell unit (QP RCS) as well as how to install and to configure the unit.

These descriptions assume that you have a working knowledge of telecommunicationhardware.

A QP RCS can host and power a single QP RC device in an unobtrusive case. Theintegrated smart power concept, including UPS batteries and forced-air cooling, deliv-ers the best working conditions for a QualiPoc Remote Control device for round theclock network monitoring tasks. Due to its clever design, the remote control shell unitsupports a wide range of QualiPoc Remote Control devices, different RF setups, andmounting options.

Fig. 5-1: QualiPoc Remote Control Shell Unit

5.1 Safety Instructions

This section describes the safety information that you need to consider before you setup, install, use, or perform maintenance on a QP RCS.

Safety Instructions

Page 67: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

67Manual Remote Control ─ 03

Improper installation and operation of a QualiPoc Remote Control Shell unit canresult in injury to yourself, damage to the equipment, and a voided equipmentwarranty.Do not attempt to install or to operate a QP RCS before you read these safety instruc-tions.

5.1.1 Important Safety Information

● Do not change and modify system components, otherwise you might void the war-ranty

● To avoid damage to the unit and to not void the warranty, only use the battery cellsand power supplies that SwissQual recommends

● Always turn off the system and remove the power cable from the unit before youchange the hardware configuration, for example, the SIM card or the QualiPocRemote Control device

● Do not drop the unit● Do not cover the air inlet on the lower edge and air outlet at the back of the unit

5.1.2 Operation and Storage Conditions

This section describes the operation and storage conditions for QP RCS.

Before you store, repair, or ship a unit, you also need to review the following sections:● chapter 5.4, "Storage", on page 75● chapter 5.6, "Repair", on page 76● chapter 5.7, "Shipping", on page 76

5.1.2.1 Operating Conditions

Table 5-1: Operating environment conditions

Environment Description

Operating environment Indoor, trains, and vehicle based

Operating Temperature -10 to 45°C for QP RCS

Operating temperature range for the device accord-ing to the device specification

Operating relative humidity < 95% rH (non-condensing)

Operating elevation 0–6500 feet (0–2000 meters)

Safety Instructions

Page 68: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

68Manual Remote Control ─ 03

5.1.2.2 Storage Conditions

Table 5-2: Storage environment conditions

Environment Description

Storage temperature From -10 to 50°C

Storage relative humidity < 95% rH (non-condensing)

Storage elevation 0–6500 feet (0–2000 meters)

Do not expose the batteries in the unit to temperatures in excess of 60 °C (140 °F).

5.2 Remote Control Shell Components

The QP RCS consists of the following main system components● QualiPoc Remote Control Shell including a QualiPoc Remote Control device● Power input cable (Part number: 04-100162)● Office power adapter (Part number: 85-100463; Description: “100..240VAC TO

14.4VDC/3.12A KFZ ADAPTOR”)● External RF antennas (not shown in figure 5-2): Depends on the use case

Fig. 5-2: Remote control shell, power adapter, and cable

Remote Control Shell Components

Page 69: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

69Manual Remote Control ─ 03

5.2.1 QualiPoc Remote Control Device

A QP RCS has room for one smartphone that runs QualiPoc in Remote Control mode.Depending on the device, you might be able to use RF pigtails as external antennas; inthis scenario, the original antennas are permanently removed. If QualiPoc freezes, theQualiPoc Remote Control mode calls on the on-device watchdog functionality to restartthe application.

5.2.2 Remote Control Shell

Fig. 5-3: Open shell

The QualiPoc Remote Control Shell has the following functionality:● Rugged case that you can use on a flat surface or mount on a wall (chapter 5.9.2,

"Drill Plan for Wall Mounting", on page 79)● Hinged lid for easy access with an optional key-lock● Device-specific mounting plate for the QualiPoc Remote Control device● Electronic board for power conditioning and UPS battery management● UPS powered fan for forced-air cooling● USB cable to power the device● USB socket that is a Dedicated Charger Port (DCP), which can deliver up to 3A● LED status lights for input power and charger status● Connector for external power source● SMA RF connector for external antennas (if supported by the device)● Reset / power button● Openings at the bottom edge for airflow

Remote Control Shell Components

Page 70: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

70Manual Remote Control ─ 03

5.2.2.1 Connector Panel

Fig. 5-4: Connector panel on back of RCS

● PWR IN: Power input● PWR: LED to display power status● CHG: LED to display charger status● RF 1 - RF 4: SMA connectors for RF pigtail antennas, which are only present if the

device has been modified by SwissQual● Reset button: Resets the QP RCS

► To reset a QP RCS, insert a screwdriver (maximum diameter of 2.5mm) to depth of10mm through the third hole from the right on the bottom row of the airflow hole,and then hold the button down for at least 30 seconds.

Fig. 5-5: Location of reset button

Note: If you hold down the RESET button less than 30 seconds, the unit does notreset. Furthermore, if the UPS batteries still have a charge, the unit simply powerson, that is, the PWR LED turns green. If this happens, hold down the RESET but-ton until the PWR LED remains off.

Table 5-3: Pin Assignment PWR IN Connector

Connector Figure Pins Comment

PWR IN1

PWR IN2

pin 1; Input; +Vdc

pin 2; Input; GND

Remote Control Shell Components

Page 71: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

71Manual Remote Control ─ 03

Table 5-4: Power Status LED

PWR Status

Off Unit is off

Green PWR IN is valid range: Unit is powered by PWR IN

Red UPS Battery is empty: Unit will shut down

Yellow No power at PWR IN: Unit runs on UPS

Table 5-5: Charger Status LED

CHG Status

Off No power at PWR IN: System is running on UPS

Blue UPS Battery is fully charged: Charger has stoppedcharging

Yellow UPS Battery is being charged

Green UPS Battery is close to being fully charged

5.2.2.2 Power Input Cable

Fig. 5-6: PWR IN cable

The 3 m long power input cable (PWR IN) that comes with the SP RCS unit connectsthe unit to a cigarette lighter socket in a vehicle or a 12V office power adapter. Thecable is protected by a 5 A fuse inside the cigarette lighter plug. For more information,see chapter 5.6.1, "Replacing a Fuse", on page 76.

Remote Control Shell Components

Page 72: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

72Manual Remote Control ─ 03

5.2.2.3 Office Power Adapter

Fig. 5-7: Office power adapter

The office power adapter has the following specifications:● AC Input: 100-240 VAC, 50/60 Hz

– 2 m cable● DC Output: 14.4V / 3A

– 1.5 m cable with cigarette lighter socket

5.3 Using a QualiPoc Remote Control Shell

The following sections describe how to use the QP RCS.

5.3.1 SIM Card

The QP RCS does not have a SIM card slot. If you want to replace the SIM of theQualiPoc Remote Control device in the QP RCS, you need to remove the device fromthe unit.

To replace the SIM card

1. If present, open the lock on the case.

2. Open the lid with the latch on the right front edge of the case.

3. Turn the QualiPoc Remote Control device off.

4. Disconnect the USB cable from the device.

5. Remove the small locking plate from the top of the device.

6. Remove the QualiPoc Remote Control device from the holding plate and insert orexchange the SIM card of the device.

Using a QualiPoc Remote Control Shell

Page 73: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

73Manual Remote Control ─ 03

7. Place the device back into the holding plate.

8. Replace the small locking plate on top of the device.

9. Connect the USB cable to the device.

Note: If the device does not power on after a few seconds, check the cable con-nection.

10. Close the lid of the QP RCS and press the lid until the latch locks into place.

5.3.2 Indoor Installation

For indoor use, SwissQual recommends the following points:● Choose a dry location where the ambient temperature is within the operating range

specification of the QualiPoc Remote Control device● Ensure that the location has sufficient RF coverage (without external antennas)● Ensure that the location is within range of a mains outlet, that is, the combined

lengths of the office power adapter cable and the power input cable● Use the drill plan in chapter 5.9.2, "Drill Plan for Wall Mounting", on page 79 for a

direct wall mount

5.3.3 Vehicle Installation

SwissQual recommends the following points when you install a QP RCS in a vehicle:● Use QualiPoc Remote Control devices that support external RF antennas● For the best cooling performance, place the unit in the air conditioned passengers

compartment of the vehicleIf you want to place the unit in the trunk of the vehicle, ensure that the air flowbetween the trunk and the air conditioned compartment is enough to maintain anambient temperature within the operating temperature range of the QulaiPocdevice

● Ensure that a cigarette lighter socket is within the range of the power input cable● If possible, keep the unit in an upright position for maximum airflow

The QP RCS automatically switches to the internal UPS for power when the input volt-age drops from 12 to 11.5Vdc , this to protect the vehicles battery from deep dischargeat vehicle installation

5.3.4 Operation

This section describes how to turn a QP RCS on and off.

Using a QualiPoc Remote Control Shell

Page 74: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

74Manual Remote Control ─ 03

To turn on a QP RCS

1. Ensure that the power input cable is connected to the cigarette lighter socket of thepower source, that is, vehicle or office power adapter, and the QP RCS.

2. Open the case according to the instructions in chapter 5.3.1, "SIM Card",on page 72.

3. Connect the power input cable to the PWR IN connector on the QP RCS.

The QualiPoc Remote Control device automatically starts.

4. Ensure that the device is in Remote Control mode.For more information, see chapter 2.2, "Installing and Configuring QualiPoc",on page 10.

5. Close the case according to the instructions in chapter 5.3.1, "SIM Card",on page 72.

The QP RCS appears in NQView and NQWeb after start up.

To turn off a QP RCS

1. Open the case according to the instructions in chapter 5.3.1, "SIM Card",on page 72.

2. Turn the QualiPoc Remote Control device off with its power button.

3. Disconnect the power input cable from PWR IN socket of the QP RCS.

4. Press and hold the RESET button for at least 30 seconds to completely turn offinternal UPS.For the location of the RESET button, see chapter 5.2.2.1, "Connector Panel",on page 70.

5.3.5 UPS Functionality

A QP RCS has integrated UPS batteries that maintains power to the cooling fan duringpower interruptions indoors or short voltage dips in a vehicle to prevent overheating. Ifthe original battery of the QualiPoc Remote Control device is replaced by an electronicbattery emulation, the UPS delivers power to the phone as well.

The UPS batteries provide the following functionality:● 3 hours of bridge power for the QP RCS fan● Average recharge time of 4 hours● UN test certified

If the device battery reaches the energy threshold that you configured, which is 80% bydefault, QualiPoc Remote Control stops the measurement; however, the deviceremains accessible to NQView and NQWeb so long as the battery has power.

Using a QualiPoc Remote Control Shell

Page 75: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

75Manual Remote Control ─ 03

5.4 Storage

To store the QualiPoc Remote Control Shell

1. Open the unit according to the intstruction inchapter 5.3.1, "SIM Card", on page 72and turn off the QualiPoc Remote Control device.

2. Disconnect all the cables.

3. Press and hold the reset button for at least 30 seconds to completely power off theunit, that is, the PWR LED must be off.

Note: For the location of the reset button, see figure 5-4.

In the event of fire, use a CO2 extinguisher.Do not user water.

5.5 Maintenance

5.5.1 Replacing Batteries

The QP RCS contains 2 lithium-ion batteries that have a lifespan of about 600 cyclesor 3 years. SwissQual recommends that you replace this battery after 3 years to pre-serve the UPS functionality.

Only use UPS batteries that are provided by SwissQual (part number: 27-100043). Ifyou require replacement batteries, please contact our support center.Please consult the Customer Support Center.pdf document for the best methodto contact us.Do not send the old or defective batteries to SwissQual, but rather dispose of themlocally.

Replace the battery of the QualiPoc Remote Control device with a battery from theoriginal manufacturer and dispose of the old or defective battery locally.

The QualiPoc Remote Control device batteries are not covered by the SwissQual sys-tem warranty. Consult the warranty of the device manufacture for the warranty details.

Storage

Page 76: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

76Manual Remote Control ─ 03

5.5.2 Cleaning

You can wipe the shell with a slightly damp cloth.

To prevent short circuits, do not soak the cloth in water.Do not use abrasives of solvents to clean the QP RCS.

5.6 Repair

5.6.1 Replacing a Fuse

● QP RCS contains only self-recovering poly-fuses● The Input Power Cable contains a 5A / 36VDC Torpedo-Fuse.

Only replace the fuse with the matching type. The fuse is also known as an ATS or aBosch fuse, type acc. DIN 72581-1.

5.7 Shipping

Use the following guidelines when you ship a QP RCS:● Prepare the unit according to the guidlines in chapter 5.4, "Storage", on page 75● To prevent mechanical damages during transportation, ensure that you completely

wrap each QP RCS separately in foam or bubble wrap.● Do not ship old or defective device batteries or UPS batteries, but rather dispose of

the batteries locally

Even though a QP RCS contains 2 Li-Ion batteries for the UPS, the unit is not a dan-gerous good with respect to current international transport regulations because thetotal wattage of the batteries is less than 100 Wh. As such, the UPS batteries are UNtest certified.

Repair

Page 77: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

77Manual Remote Control ─ 03

5.7.1 Warranty Information

Changes to a QP RCS that are not approved by SwissQual void the warranty.Such changes also include power supplies.

SwissQual does not accept liability for damage that occurs due to the improper installa-tion of hardware components in office or in a vehicle. Only a qualified technician, pref-erably one that has been trained by SwissQual, should install the unit.

SwissQual is in no way liable for any damage that results from the mishandling of thisproduct or by a vehicle accident.

If you require assistance for installation, reinstallation, configuration, extension, mainte-nance, or repair of your SwissQual hardware, please contact our support center.Please consult the Customer Support Center.pdf document for the best methodto contact us.

5.8 Troubleshooting

This section describes how to troubleshoot a problem with a QP RCS.

When you contact our support center about a QP RCS, ensure that you have the fol-lowing information:● Serial number of the affected unit● Description of the physical setup of the system, for example, power source, RF

setup and your use case● QualiPoc software version

Please consult the Customer Support Center.pdf document for the best methodto contact us.

5.8.1 Device Does Not Start Up

Use the following checklist if a QP RCS does not start when you connect a powersource to the PWR IN connector.

1. If the PWR status LED is not green, then perform the following actions:

a) Check the connection of the power input cable to the QP RCS.b) Check the connection of the cigarette lighter plug to the socket.c) Check if the cigarette lighter socket delivers 12Vdc.d) Check the fuse in the power input cable.

Troubleshooting

Page 78: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

78Manual Remote Control ─ 03

2. Verify that the USB cable is connected to the device and to the USB socket of theelectronic board.

3. Try to start the QualiPoc Remote Control device with the power button on thedevice.

● If the device turns on, ensure that auto startup is enabled the Remote Controlmode settings in QualiPoc.For more information, see chapter 2.2, "Installing and Configuring QualiPoc",on page 10.

● If the device remains off, replace the device battery, and try to start the deviceagain.

4. If the problem persists, contact our support center.Please consult the Customer Support Center.pdf document for the bestmethod to contact us.

5.8.2 CHG LED Does Not Turn Green or Blue After 4h When PWR IN isConnected

Press to check if the batteries are correctly inserted in the holder. if the batteries arecorrectly inserted, then you need to replace the batteries according to chapter 5.5.1,"Replacing Batteries", on page 75

5.9 Technical Specification

This section provides an overview of the technical specifications for QP RCS.

5.9.1 Dimensions and Weights

● Dimensions: 200 mm x 195 mm x 80 mm● Weight: 800g without QualiPoc Remote Control device

Technical Specification

Page 79: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

79Manual Remote Control ─ 03

Fig. 5-8: Dimensions of Remote Control Shell

5.9.2 Drill Plan for Wall Mounting

When you mount a QP RCS on wall, ensure that the PWR IN socket points to the floor.This orientation, such that the FAN can benefit from natural convection! Keep a zone of6cm free to any obstacle at the PWR IN side, to have enough space for the connectors(PWR and RF if needed).

Use the following diagram as a guide for drilling the holes to mount the QP RCS on awall.

If you print this page, you need to scale up the diagram with a photocopier until thedimensions are correct. Otherwise you can draw the diagram yourself with a ruler.

Technical Specification

Page 80: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

80Manual Remote Control ─ 03

5.9.3 Electrical and Conformance Specification

Table 5-6: Electrical Specification QualiPoc Remote Control Shell

Parameter Value

Input Voltage 11.5 – 17.5 V (initial start-up voltage > 11.9V)

Input Frequency DC

Typical Pwr Consumption, UPS charged 5 W ([email protected])

Max Pwr Consumption, UPS charging 32W ([email protected])

Technical Specification

Page 81: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

81Manual Remote Control ─ 03

The typical power consumption is dependent on your test scenarios and device, thegiven value reflects an average regarding devices / test scenario.

Table 5-7: Conformance QualiPoc Remote Control Shell

Conformance Description

CE A CE statement in accordance to European Direc-tives 2004/108/EC, 2006/95/EC and 72/245/EECcan be obtained from our support center.

EMC According to the 2004/108/EC harmonized stand-ard:● EN 61326-1: 2006, Electrical equipment for

measurement, control and laboratory● EN 55022: 2006, Emission – Industrial environ-

ment● EN61000-6-1: 2005, Immunity for industrial

environment

Safety IEC/EN60950-1, measurement devices

Automotive According technical standard for e/E Mark:● Directive 72/245/EEC, including last update

2009/19EC● EN55025: 2006● IEC/EN 11452-1 2005● ISO 7637-2: 2004

Shock Pending

IEC/ EN 60068-2-27, 30G, operational

Vibration Pending

IEC/ EN 60068-2-64,operational, 3 axis, f = 5…40Hz, PSD = 2 G/Hz, 6dB decr./oct to 500Hz

Temperature IEC/ EN 60068-2-14, Operational, -10°..45°C

Please consult the Customer Support Center.pdf document for the best methodto contact us.

5.10 Installing a QP RCS in a Vehicle

SwissQual offers the optional Vehicle Mounting Plate (VMP) and Vehicle Mounting Kit(VMK) to facilitate in-vehicle installation of multiple QP RCS units.

Installing a QP RCS in a Vehicle

Page 82: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

82Manual Remote Control ─ 03

Fig. 5-9: VMK with a QP RCS and an RF combiner

Fig. 5-10: RCS vehicle mounting plate

A VMP and a VMK have mounting points for one QP RCS and one RF combiner. AnRF combiner simplifies antenna distribution when you have several QP RCS in yourvehicle.

A VMK also has a power distribution that can supply up to 3 QP RCS.

Installing a QP RCS in a Vehicle

Page 83: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

83Manual Remote Control ─ 03

Fig. 5-11: RCS vehicle mounting kit

Installing a QP RCS in a Vehicle

Page 84: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

84Manual Remote Control ─ 03

The VMK must be installed by a trained vehicle electrician.The wiring must be of the appropriate gauge and the battery plus wire must be fusedaccording the wire gauge.To run 3 QP RCS in parallel, you need to use at least a 7.5A fuse; however, you needto ensure that the wiring can carry the maximum current that the fuse allows. The pur-pose of the fuse is to protect the wiring and not the QP RCS. The QP RCS equipmenthas its own protection.Power-IN terminal: Pin 1 connects to the positive terminal of the 12V battery and Pin 2connects to ground, that is, the vehicle chassis

+12V (car battery plus)

GND (car chassis)

Power IN terminal

Fig. 5-12: VMK wiring diagram

5.10.1 Mounting Options

The VMP and the VMK both have 14 screw holes for mounting a QP RCS to a vehiclechassis with ST4.8x19 screws. figure 5-13 shows the minimum 6 screw configuration.

Fig. 5-13: Minimum mounting screw configuration

Installing a QP RCS in a Vehicle

Page 85: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

85Manual Remote Control ─ 03

If you mount the plates end to end, see figure 5-14, use 2 screws to join the plates.

5.10.1.1 Side By Side Mounting

The following figures show the side by side mounting options for VMP and VMK plates.

RCS VMP RCS VMPRCS VMK

(with RF Combiner)

Fig. 5-14: Side By Side mounting option 1

RCS VMP RCS VMPRCS VMK(with RF Combiner)

Fig. 5-15: Side By Side mounting option 2

5.10.1.2 End to End Mounting

The following figures show the end to end mounting options for VMP and VMK plates.

Installing a QP RCS in a Vehicle

Page 86: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

86Manual Remote Control ─ 03

RCS VMP

RCS VMP

RCS VMK(with RF Combiner)

Fig. 5-16: End to end mounting option 1

Installing a QP RCS in a Vehicle

Page 87: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

87Manual Remote Control ─ 03

RCS VMP

RCS VMP

RCS VMK(with RF Combiner)

Fig. 5-17: End to end mounting option 2

5.10.2 Connecting the QP RCS PWR-IN Cable

To connect the QP RCS power input cable to a VMK

1. Remove the red cap from the cigarette lighter adapter on the power input cable.

Installing a QP RCS in a Vehicle

Page 88: Manual - QualiPoc Remote Control

QualiPoc Remote Control ShellSwissQual®...QualiPoc

88Manual Remote Control ─ 03

a) Turn the red cap left.

1. Turn left 2. Pull off

Fig. 5-18: Remove red cap from cigarette lighter adapter

b) Pull the red cap off.

Fig. 5-19: Cigarette lighter adapter without red cap

Note: Do not throw out the red cap. You need the cap if you want to connect thecable to a cigarette lighter socket. To reattach the cap, do these steps in reverse.

2. Connect the power input cable to the PWR IN connector on the QP RCS.

3. Connect the cigarette lighter adapter to the power distribution of the VMK.

5.10.3 Connecting Antennas to RF Combiner

If you want to use external antennas with an RF combiner, the possible configurationsdepend on the number of QualiPoc Remote Control devices and the number of anten-nas. For help in determining the best setup, contact our support center.

Please consult the Customer Support Center.pdf document for the best methodto contact us.

Installing a QP RCS in a Vehicle

Page 89: Manual - QualiPoc Remote Control

Glossary: AbbreviationsSwissQual®...QualiPoc

89Manual Remote Control ─ 03

Glossary: AbbreviationsE

ESD: Electrostatic Discharge

IIATA: International Air Transportation

QQP RCS: QualiPoc Remote Control Shell unit

UUPS: Uninterruptable Power Supply

VVMK: QP RCS Vehicle Mounting Kit

VMP: QP RCS Vehicle Mounting Plate