3
Temperature Time Controller Operating Instructions This section controller integrated temperature control and time relay function. Using industrial grade microcontroller (microcomputer) designs. In line with weak safety circuit design, each with two strong electric circuit boards, strong, weak completely isolated. Temperature control function: One. Temperature Range: -9 ~ 99 ° C; error + -1 ° C. Middle red LED display sensor sensitive to the actual temperature. About green digital tube display the temperature set by the user to stop and start temperature. Because there are two kinds of heating control and cooling control needs, so this section controller is also a "hot start" and "cold start" two modes of operation. 1. hot start (cooling control): When the "start temperature" is greater than "stop temperature", the thermostat is in the "hot start" "state, for example: If the left measured temperature 26 ° C," stop temperature "is set to 20 ° C, "start temperature" is set to 30 ° C. the machine is turned on, running lights (green Xiao) light, then the power supply socket when the measured temperature at 20 ° C or less, the standby indicator (red) light, At this outlet is powered off. this start-up mode is mainly used for cooling, such as the open air, exhaust fans, etc. 2. Cold start (heating control): When the "start temperature" less than "stop temperature", the thermostat is in the "cold start" state. For example: Set "Stop temperature" of 30 ° C, "start temperature" of 20 ° C, then when the measured temperature at 20 ° C or less, running lights (green) light, then the power supply socket. When the measured temperature is higher than 30 ° C, the standby indicator (red) light, then the socket is powered off. This start-up mode is mainly used for heating. 3. Alarm: temperature sensor fault or temperature detection <-9 ° C or> 99 ° C, the buzzer alarm, digital display "Er." Cutting off the power supply socket. Troubleshooting is restored to normal. Multi-purpose: for boilers, pumps, water heaters, electric heating equipment, geothermal water heating, geothermal membranes, floor heating, heating cables, electric kang, electric painting, hot fan, incubators, farms, breeding room, bacteria ferment temperature control seed germination and other places. 二.Simple and practical additional function (easy to operate time relay): Press the function key SET between temperature, F1, F2, F3 four modes. 1. "F1" is intermittent time control mode. (Similar to the refrigerator soulmates function) intermediate digital display "F1". F1 stop time corresponding to the left: Press the arrow keys (1 to 99 minutes) setting. F1 on the right corresponds to the opening time: press the arrow keys (1 to 99 minutes) setting. Such as setting the "05" in the figure on the left

Manual for ThermocontrollerPY-SM5

  • Upload
    harris

  • View
    212

  • Download
    0

Embed Size (px)

DESCRIPTION

Manual for Thermocontroller with Timer Device PY-SM5

Citation preview

  • Temperature Time Controller Operating Instructions

    This section controller integrated temperature control and time relay function. Using

    industrial grade microcontroller (microcomputer) designs. In line with weak safety circuit

    design, each with two strong electric circuit boards, strong, weak completely isolated.

    Temperature control function:

    One. Temperature Range: -9 ~ 99 C; error + -1 C. Middle red LED display sensor

    sensitive to the actual temperature. About green digital tube display the temperature set

    by the user to stop and start temperature. Because there are two kinds of heating

    control and cooling control needs, so this section controller is also a "hot start" and "cold

    start" two modes of operation.

    1. hot start (cooling control): When the "start temperature" is greater than "stop

    temperature", the thermostat is in the "hot start" "state, for example: If the left measured

    temperature 26 C," stop temperature "is set to 20 C, "start temperature" is set to 30

    C. the machine is turned on, running lights (green Xiao) light, then the power supply

    socket when the measured temperature at 20 C or less, the standby indicator (red)

    light, At this outlet is powered off. this start-up mode is mainly used for cooling, such as

    the open air, exhaust fans, etc.

    2. Cold start (heating control): When the "start temperature" less than "stop

    temperature", the thermostat is in the "cold start" state. For example: Set "Stop

    temperature" of 30 C, "start temperature" of 20 C, then when the measured

    temperature at 20 C or less, running lights (green) light, then the power supply socket.

    When the measured temperature is higher than 30 C, the standby indicator (red) light,

    then the socket is powered off. This start-up mode is mainly used for heating.

    3. Alarm: temperature sensor fault or temperature detection 99 C, the

    buzzer alarm, digital display "Er." Cutting off the power supply socket. Troubleshooting

    is restored to normal.

    Multi-purpose: for boilers, pumps, water heaters, electric heating equipment, geothermal

    water heating, geothermal membranes, floor heating, heating cables, electric kang,

    electric painting, hot fan, incubators, farms, breeding room, bacteria ferment

    temperature control seed germination and other places.

    Simple and practical additional function (easy to operate time relay):

    Press the function key SET between temperature, F1, F2, F3 four modes.

    1. "F1" is intermittent time control mode. (Similar to the refrigerator soulmates function)

    intermediate digital display "F1". F1 stop time corresponding to the left: Press the arrow

    keys (1 to 99 minutes) setting. F1 on the right corresponds to the opening time: press

    the arrow keys (1 to 99 minutes) setting. Such as setting the "05" in the figure on the left

  • F1, F1 on the right to set "10", that is down 5 minutes, turn 10 points. Shutdown red

    light, green light when turned on, and so on.

    2. "F2" Countdown time control mode. Setting range: between 0001 and 9999 minutes.

    Corresponding time left: 00 to 99 set. The right of the corresponding time: 00 to 99 set.

    Corresponding to the left is the timing of one thousand one hundred. The right of the

    corresponding bit timing is ten times. As the left the left side LED is set to "12" to the

    right of the digital control is set to "00", the timing for 1200 minutes, or 20 hours.

    Reaches the set time outlet power failure indicator is off, the red light. Application time

    off, such as the timing of charging electric vehicles and so on.

    3."F3" appointment time control mode. Setting range: between 0001 and 9999 minutes.

    Corresponding time left: 00 to 99 set. The right of the corresponding time: 00-99 setting.

    Corresponding to the left is the timing of one thousand one hundred. The right of the

    corresponding bit timing is ten times. As the left is set to make an appointment 20

    minutes, 20 minutes after the green light is on, the outlet has power. Range of

    applications, timing subpages about boot.

    Setting memory function: the thermostat will save your settings, automatically save the

    data you have set no key operation after 30S. When set to ensure that power is not lost,

    not the other dead set.

    Special Note: Due to technology, the sensor cable is 10 centimeters in thermostat

    inside, so the outside of the probe length than the length of the thermostat you purchase

    10 centimeters shorter.

    Brand:

    Model: PY-SM5

    Dimensions: 147x97x45

    Rated voltage: AC 220V / 50Hz

    Load capacity: 1500 W (resistive load)

    Stop temperature

    Function

    Start temperature