Temperature Time Controller Operating Instructions
This section controller integrated temperature control and time relay function. Using
industrial grade microcontroller (microcomputer) designs. In line with weak safety circuit
design, each with two strong electric circuit boards, strong, weak completely isolated.
Temperature control function:
One. Temperature Range: -9 ~ 99 C; error + -1 C. Middle red LED display sensor
sensitive to the actual temperature. About green digital tube display the temperature set
by the user to stop and start temperature. Because there are two kinds of heating
control and cooling control needs, so this section controller is also a "hot start" and "cold
start" two modes of operation.
1. hot start (cooling control): When the "start temperature" is greater than "stop
temperature", the thermostat is in the "hot start" "state, for example: If the left measured
temperature 26 C," stop temperature "is set to 20 C, "start temperature" is set to 30
C. the machine is turned on, running lights (green Xiao) light, then the power supply
socket when the measured temperature at 20 C or less, the standby indicator (red)
light, At this outlet is powered off. this start-up mode is mainly used for cooling, such as
the open air, exhaust fans, etc.
2. Cold start (heating control): When the "start temperature" less than "stop
temperature", the thermostat is in the "cold start" state. For example: Set "Stop
temperature" of 30 C, "start temperature" of 20 C, then when the measured
temperature at 20 C or less, running lights (green) light, then the power supply socket.
When the measured temperature is higher than 30 C, the standby indicator (red) light,
then the socket is powered off. This start-up mode is mainly used for heating.
3. Alarm: temperature sensor fault or temperature detection 99 C, the
buzzer alarm, digital display "Er." Cutting off the power supply socket. Troubleshooting
is restored to normal.
Multi-purpose: for boilers, pumps, water heaters, electric heating equipment, geothermal
water heating, geothermal membranes, floor heating, heating cables, electric kang,
electric painting, hot fan, incubators, farms, breeding room, bacteria ferment
temperature control seed germination and other places.
Simple and practical additional function (easy to operate time relay):
Press the function key SET between temperature, F1, F2, F3 four modes.
1. "F1" is intermittent time control mode. (Similar to the refrigerator soulmates function)
intermediate digital display "F1". F1 stop time corresponding to the left: Press the arrow
keys (1 to 99 minutes) setting. F1 on the right corresponds to the opening time: press
the arrow keys (1 to 99 minutes) setting. Such as setting the "05" in the figure on the left
F1, F1 on the right to set "10", that is down 5 minutes, turn 10 points. Shutdown red
light, green light when turned on, and so on.
2. "F2" Countdown time control mode. Setting range: between 0001 and 9999 minutes.
Corresponding time left: 00 to 99 set. The right of the corresponding time: 00 to 99 set.
Corresponding to the left is the timing of one thousand one hundred. The right of the
corresponding bit timing is ten times. As the left the left side LED is set to "12" to the
right of the digital control is set to "00", the timing for 1200 minutes, or 20 hours.
Reaches the set time outlet power failure indicator is off, the red light. Application time
off, such as the timing of charging electric vehicles and so on.
3."F3" appointment time control mode. Setting range: between 0001 and 9999 minutes.
Corresponding time left: 00 to 99 set. The right of the corresponding time: 00-99 setting.
Corresponding to the left is the timing of one thousand one hundred. The right of the
corresponding bit timing is ten times. As the left is set to make an appointment 20
minutes, 20 minutes after the green light is on, the outlet has power. Range of
applications, timing subpages about boot.
Setting memory function: the thermostat will save your settings, automatically save the
data you have set no key operation after 30S. When set to ensure that power is not lost,
not the other dead set.
Special Note: Due to technology, the sensor cable is 10 centimeters in thermostat
inside, so the outside of the probe length than the length of the thermostat you purchase
10 centimeters shorter.
Brand:
Model: PY-SM5
Dimensions: 147x97x45
Rated voltage: AC 220V / 50Hz
Load capacity: 1500 W (resistive load)
Stop temperature
Function