23
SHARING SESSION-2 M2000 3G By Paulus Cahyo Sumarno (paulus.cahyo@gmail.

M2000 3G MML Command

Embed Size (px)

DESCRIPTION

M2000 3G MML Command

Citation preview

Page 1: M2000 3G MML Command

SHARING SESSION-2M2000 3G

By Paulus Cahyo Sumarno ([email protected])

Page 2: M2000 3G MML Command

M2000 3G1. NodeB MML Command

2. RNC MML Command

Right click on NodeB, select MML Command

Right click on RNC, select MML Command

Page 3: M2000 3G MML Command

NODE-B MML COMMAND

1. Checking NODEB LICENSE2. Checking NODEB CE Board Capacity3. Checking NODEB WRFU Power Max4. Checking NODEB TX Power Max NodeB5. Checking NODEB CELL/SECTORS6. Checking NODEB VSWR board & Alarm7. Checking NODEB R99 Algorithm & Congestion Control parameter8. Checking NODEB E1 IP capacity & status

Page 4: M2000 3G MML Command

NODE-B MML COMMAND1. Checking NODEB LICENSE

DSP LICENSE;

Page 5: M2000 3G MML Command

NODE-B MML COMMAND2. Checking NODEB CE Board Capacity

DSP BRD;

DSP BBPTC;

This command only exist in BTS3900

CE BOARD TYPE :HBBI ==> UL/DL = 128/256EBBI ==> UL/DL = 384/384WBBPa ==> UL/DL = 128/256WBBPb1 ==> UL/DL = 64/64WBBPb2 ==> UL/DL = 128/128WBBPb3 ==> UL/DL = 256/256WBBPb4 ==> UL/DL = 384/384

Page 6: M2000 3G MML Command

NODE-B MML COMMAND3. Checking NODEB WRFU Power Max

DSP BRD;

DSP BRDMFRINFO;

Page 7: M2000 3G MML Command

NODE-B MML COMMAND4. Checking NODEB TX Power Max NodeB

LST LOCCELL;

LST LOCELL:MODE=LOCALCELL,LOCELL=1;

Page 8: M2000 3G MML Command

NODE-B MML COMMAND5. Checking NODEB CELLS/SECTORS

LST LOCCELL;

DSP LOCCELL; LST SEC;

In Pico, better not connect 2 feeders to RX_aand RX_b. But not in Macro sites.

Page 9: M2000 3G MML Command

NODE-B MML COMMAND6. Checking NODEB VSWR board and Alarm Active

DSP VSWR;

DSP ALMAF;

Page 10: M2000 3G MML Command

NODE-B MML COMMAND7. Checking NODEB R99 Algorithm & Congestion Control parameter

LST R99ALGPARA;

LST CONGCTRLPARA;

Page 11: M2000 3G MML Command

NODE-B MML COMMAND7. Checking NODEB E1 IP capacity & status

DSP E1T1

DSP DEVIP

Page 12: M2000 3G MML Command

RNC MML COMMAND

1. Checking BASIC Configuration of NodeB2. Checking RESELECTION CELL3. Checking NEIGHBOR RELATION 3G-3G & 3G-2G4. Checking IRAT2G & SHO parameters5. Checking E1 based on RNC6. Checking Code configuration7. Etc..

Page 13: M2000 3G MML Command

RNC MML COMMAND1. Checking BASIC Configuration of NodeB

LST UNODEB;This command to see the cellname, sectors, configured E1 in RNC.

Check the consistency between nb of E1 in NodeB

Page 14: M2000 3G MML Command

RNC MML COMMAND2. Checking RESELECTION CELL

LST UCELLSELRESEL;

Page 15: M2000 3G MML Command

RNC MML COMMAND3. Checking NEIGHBOR RELATION 3G-3G & 3G-2G

LST UINTRAFREQNCELL; to see 3G adj cell and its adjacency parameters

LST U2GNCELL; to see 2G adj cell and its adjacency parameters

Page 16: M2000 3G MML Command

RNC MML COMMAND4. Checking IRAT2G & SHO parameters

LST UCELLINTERRATHOCOV; cell LST UINTERRATHOCOV; RNC

Page 17: M2000 3G MML Command

CASES-NCCR

1. Power Congestion2. Code Congestion3. IuB Congestion4. CE Congestion

Problem Solving of :

Page 18: M2000 3G MML Command

Power Congestion

For UL Power Congestion : 1st Solution Step:1. Check MAXTXPOWER per Cell in LST UCELL2. Upgrade from 430 to 460 (RNC and NodeB must be set the same)

2nd Solution Step:1. Check LST UCELLCAC2. Check UL total equivalent user number (ULTOTALEQUSERNUM) max setting is 2003. If it’s still default, then upgrade it to 150 or 2004. Then Check LST UCELLALGOSWITCH5. Set NBMUlCacAlgoSelSwitch (Uplink CAC algorithm switch ) = ALGORITHM_SECOND6. Set NBMDlCacAlgoSelSwitch (Downlink CAC algorithm switch) = ALGORITHM_FIRST

3rd Solution Step:1. Check LST UCELLALGOSWITCH2. In NBMLdcAlgoSwitch, Set UL_UU_LDR (Uplink UU LDR Algorithm: )=1 (ON)3. Then check UCELLLDR,4. Set UlLdrFirstAction (UL LDR first action) = BERateRed(BE traff rate reduction),

UlLdrBERateReductionRabNum=1, GoldUserLoadControlSwitch=ON

Page 19: M2000 3G MML Command

Power Congestion

For DL Power Congestion :

1st Solution Step:1. Check LST UCELLCAC2. Check DL total equivalent user number (ULTOTALEQUSERNUM) max setting is 2003. If it’s still default, then upgrade it to 150 or 2004. Check DL total power threshold (default is 90%), Set to 95%5. Then Check LST UCELLALGOSWITCH6. Set NBMDlCacAlgoSelSwitch (Downlink CAC algorithm switch ) =

ALGORITHM_SECOND

2nd Solution Step:1. Check LST UCELLALGOSWITCH2. Set DL_UU_LDR (Downlink UU LDR Algorithm: )=1 (ON)3. Then check UCELLLDR,4. Set DlLdrFirstAction (DL LDR first action) = BERateRed(BE traff rate reduction),

DlLdrBERateReductionRabNum=1, GoldUserLoadControlSwitch=ON

To see the effect of LDRVS.LCC.LDR.InterFreqVS.LCC.LDR.BERateDLVS.LCC.LDR.BERateUL

Page 20: M2000 3G MML Command

Code Congestion

For any code congestion :1.Check the traffic distribution in Mapinfo, and do traffic sharing using adjacent parameter changing2.In crowded area (a lot of nodeB cell servings), reduce the active set numbers (3 2) . This will impact to the code used for reselection process3.Reduce HS-SCCH’s code number from 4 to 2. HS-SCCH (max 4 per UE) is only used to decode the next HSPDSCH frame4.Reduce User Number for Code Adjust for HSDPA = 3 (This is used in LDR, but in code reshuffling, it also need 2 codes in the process, this mean in the same time total code that will be used is 6 codes)5.Increase maximum number of HSDPA in a cells6.Set the Allocate Mode HSDPA to automatic, and set the proper number of HS-PDSCH code7.Activate code LDR Algorithm and set the LDR on 1st action with Code Adjust8.Add 2nd, 3rd, etc carriers9.owntilt the antenna10.Etc..

Page 21: M2000 3G MML Command

Code Congestion

For any Iub congestion :1.Add E1/IP migration2.Create FTI (Factor Table Index)3.In new created FTI, reduce the percentage number of packet transmitted in Iub (PSINTERDL, PSINTERUL, PSBKGDL, PSBKGUL, etc)

To create TFI :

1. Add TRMFACTOR (to set the reduced PS in Iub)2. Check ADJNODE (Check ANI of the nodeB)3. Set ADJMAP for FTI

Page 22: M2000 3G MML Command

Code Congestion

Other NCCR

1. MOD UCELLRLACTTIME : OAMGUARDVALFORHIGHRATE (H-Rate RL NodeB Message

Processing Time) no response/no reply2. MOD UFACH : Max Transmit Power of FACH (No response/no reply)3. MOD UCELLSETUP (MOD UCELL) : NINSYNCIND, NOUTSYNCIND, & TRLFAILURE4. MOD UINTRAFREQNCELL (adjacent parameter) : IdleQoffset1sn[dB],

IdleQoffset2sn[dB], ConnQoffset1sn[dB], & ConnQoffset2sn[dB]5. HSPA+ Activation : DSP LICENSE (activate DL 64QAM Function)

LST UCELLALGOSWITH : Cell Hspa Plus function switch = Cell 64QAM Function Switch : ON & Cell 64QAM+MIMO Function Switch::ON

Page 23: M2000 3G MML Command

THANKS & GOOD LUCK TO YOU FRIENDS