Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
1
2
Operation viaClient SoftwareTestingPowering OnWiring
Network
Security Control Panel
with Bus Extension Module
Quick Start Guide
Connect the keypad, alarm output, trigger, and power cables,with following the figure below. Power down the control panelbefore connecting and disconnecting accessories and peripherals.
Step 1 Wiring
The keypad registration will be completed in 1 minute after the control panel being power on. The system then will complete the start-up and enter the properly status of working in 20 seconds.While the registration is succeeded, the working status indicator of LED keypad will turn green.The display demonstration of LCD keypad after powering on is shown below.
HIKVISION 20XX.XX.XX XX:XX:XXVX.X.X build XXXXXX
Step2 Powering On
Dry Contact Dry Contact Dry Contact Dry Contact
2.2KΩNC
C
Z
G
Peripheral Security Detector
NC Detector
2.2KΩ
NO
C
Z
G
Security Control PanelSecurity Control Panel Security Control Panel
NO Detector
Peripheral Security Detector
Zone
Zone
Alarm Output
KeypadPower Supply
G Z4 G Z6Z5 G Z8Z7GZ1 Z2 Z3
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
NO/NC1COM1 COM2 COM3 COM
NO/NC2 NO/NC3 NO/NC4
G Z4 G Z6Z5 G Z8Z7GZ1 Z2 Z3
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
TX RX G
PrinterDry Contact Dry Contact Dry Contact Dry Contact
D + +D G12V -
Keypad
DC_IN +GBAT
_ +12V G+12V G
14.3V DCPower
12VDC 7AHLead-acid
AlarmBell
Auxiliary Power
Interface
BELL AUX
Network Data Indicator
14.3 Power Indicator
Reset
TAMPER1
BELL AUX
FUSEKEYPAD Network Status Indicator
Working Indicator
3.3V Power Indicator
G Z10Z9
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
G Z12Z11
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
G Z14Z13
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
G Z16Z15
N.O N.O
2.2K EOL
2.2KEOL
N.C N.C
Z9 to Z16 are only supported by the network security control panel with 16 zones.
Power Indicator
Telephone Module
HandsetIncom
ingPhone Line GPRS Module
DC
Unoccupied Zone
NO/NC1COM1 COM2 COM3 COM
NO/NC2 NO/NC3 NO/NC4
The resistance of 2.2KΩsupports tamper-proof and non-tamper-proof wiring. The resistance of3.3KΩ, 5.6KΩor 8.2KΩ only supports non-tamper-proof wiring.
BUS1- BUS2- BUS2+BUS1+ GG
M-BUS 1 M-BUS 2
5V Power Indicator
Bus Power Indicator
13.8V Power Indicator
15V,-24V Power Indicator
M-BUS Module
UD07394B
3 4 Step4 Operation via Client Software
Arm/Disarm
Clear Alarm
Test
Activate Device11
22
Add Device
3
Path: Device Management -> Server -> Online
Note: You should activate the device for the first usage.
Path: Device Management -> Server -> Add DeviceInput the device nickname, IP address, user name, and password, and click Add.Default Port No:8000Default Username:admin
For more, please refer to Security Control Panel Installation Guide.
For more, please refer to Video Security Control Panel User Manual.
If the system is working properly, the keypad alarm will
be occurred while triggering the zone.
The alarm Indicator are shown below.
LED Keypad:Channel indicator turns flicking red.
LCD Keypad:Keypad screen display alarm
information.
If the system is working properly, the
arming/disarming operation will take effect.
Enter the command above for disarming when the
system is in the arming status.
Quick Start GuideCOPYRIGHT ©2016 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED.Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinafter referred to be “Hikvision”). This user manual (hereinafter referred to be “the Manual”) cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties, guarantees or representations, express or implied, regarding to the Manual.About this Manual This manual is applicable to video security control panel.The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version in the company website (http://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals.Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned below are the properties of their respective owners.Legal DisclaimerTO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS
Step3 Testing
Arming/Disarming Command: 【User Password】+ #
Buzzer:Rapid beep sound.
Enter the command below to clear the triggered alarm.【User Password】+【*】+【1】+【#】
Online Device (2)
Add to Client
IP
xx.xx.xx.xx
xx.xx.xx.xx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxx-xx-xx xx:xx:xx
xxxx-xx-xx xx:xx:xx
8000
8000
Inactive
Active
Device Type Firmware Version Server PortSecurity Start Time
Add all Modify Netinfo Reset Password Activate Filter
Refresh Every 60s
Onlie Device (2)
Add to Client
IP
xx.xx.xx.xx
xx.xx.xx.xx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxx-xx-xx xx:xx:xx
xxxx-xx-xx xx:xx:xx
8000
8000
Inactive
Active
Device Type Firmware Version Server PortSecurity Start Time
Add All Modify Netinfo Reset Password Activate Filter
Refresh Every 60s
Add Device Modify
Nickname IP
Add
Adding Mode:
Add Offline Device
Nickname:
Address:
Port:
User Name:
Password:
Add Cancel
Export to Group
Set the device name as the group name and add all the channels connected to the device to the group.
IP/Domain IP Segment IP Server HiDDNS
Function Description Command
Programming/ Editing Password
Control Panel Programming
【Installer Password】【*】【0】【#】
Exit Operation 【*】【#】 Operator Password 【Operator Password】【*】【0】【#】
【User No. (3digits)】【#】 【New Password】【#】 【New Password】【#】
Testing Testing 【Password】【*】【6】【0】【#】 Alarm Center Testing 【Password】【*】【6】【1】【#】 Project Mode 【Password】【Project】【9】【0】【n】【#】 Exiting Project Mode 【Project】 or 【*】【#】
Arming/Disarming Normal(Away)Arming/Disarming
【Password】【#】
Instant Arming 【Password】【*】【7】【#】 Stay Arming 【Password】【*】【4】【#】
Function Description Command
Clearing Alarm Clearing Under arming status
【Password】【*】【1】【#】
Bypass Bypass Zone(n) 【Password】【Bypass】【n】【n】【n】【#】
【Password】【Bypass】【n】【n】【n】【#】
【Bypass】【n】【n】【n】【#】
nnn is the zone No.
Keypad Settings Enabling/Disabling Keypad Tone
【*】【5】【1】【#】
Enabling/Disabling Fault Prompt
【*】【5】【6】【#】
LCD Backlight Control 【*】【5】【2】【n】【n】【n】【#】 LCD Backlight Disabling
【*】【8】【#】
Restore Bypass:Enter Command Under the bypass Status
Normally Used Keypad Operation Command
Siren (Connected):Triggered.