9
An electric mechanism to lift a flat screen television. Shown for use with a Telescopic Unit and Heavy Duty Electric Flap Unit. Suitable for a total lifting weight of 30Kg [66Ibs] Maximum Screen Height 740mm [29.1] Maximum Screen Depth 60mm [2.4] Maximum Lift Distance 1315mm [51.8] (Top edge of screen to cabinet top) Lift systems to suit different screen heights are available. Check screen mounting details and request a suitable mount plate Supplied with basic infrared remote. Can be learnt by many learning remotes. Also has switch control and RS232 so can be operated by relays, switches, Crestron / AMX or Lutron systems. It is the responsibility of the installer to warn all potential end users of the dangers of interfering with mechanisms during operation WARNING IMPORTANT Mechanisms which lift or move weights need to be checked on a yearly basis for any damage which may result in an accident CONTROL SPECIFYING SUITABILITY FUNCTION DESIGN HIGHLIGHTS Quiet smooth action at approximately 40mm [1.6] per second Full cable management Wide range of mounting options 24V DC motor. Suitable for direct DC supply Robust lifting beam OPTIONS Heavy duty option NON-TELESCOPIC OPTIONS Box Enclosure with Swivel Box Enclosure Advance & Rotate Custom screen back cover www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565 LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical Sheet ISSUE 002 SHEET 1 of 9

LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

An electric mechanism to lift a flat screen television. Shown for

use with a Telescopic Unit and Heavy Duty Electric Flap Unit.

Suitable for a total lifting weight of 30Kg [66Ibs]

Maximum Screen Height 740mm [29.1]

Maximum Screen Depth 60mm [2.4]

Maximum Lift Distance 1315mm [51.8] (Top edge of

screen to cabinet top)

Lift systems to suit different screen heights are available.

Check screen mounting details and request a suitable mount plate

Supplied with basic infraredremote. Can be learnt by

many learning remotes.

Also has switch control andRS232 so can be operated by

relays, switches, Crestron /AMX or Lutron systems.

It is the responsibility ofthe installer to warn allpotential end users of

the dangers of interferingwith mechanisms during

operation

WARNING IMPORTANTMechanisms which liftor move weights need

to be checked on ayearly basis for anydamage which mayresult in an accident

CONTROL

SPECIFYING

SUITABILITY

FUNCTIONDESIGN HIGHLIGHTS

Quiet smooth action at •approximately 40mm [1.6] per second

Full cable management•

Wide range of mounting options•

24V DC motor. Suitable for direct •DC supply

Robust lifting beam•

OPTIONS

Heavy duty option•

NON-TELESCOPIC OPTIONS

Box Enclosure with Swivel•

Box Enclosure•

Advance & Rotate•

Custom screen back cover•

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 1 of 9

Page 2: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

Telescopic UnitSafety push rod to avoid finger trapping in flap

Cable management

Heavy Duty Electronic Flap unit(HF) Opens flap before lifting the screen

Robust lifting beam

Safety switched base

Screen Mount PlatesSuitable for VESA 400, 300 & 200 mounting patterns

Design HighlightsA space efficient and robust lifting mechanism.

A robust 24V DC motor with a purpose made lead screw enables a quiet and smooth lifting action at approximately 40mm [1.6] per second.

High precision linear guideways ensure stability and durability of the beam to prevent any unwanted movement of the screen.

Adjustable UP and DOWN positions allow for a precise final setup within the cabinet.

The safety switched base reduces the risk of damage to the mechanism or injury to the user by cutting power to the motor when there is an obstruction between the cabinet and base panel.

Full cable management protects all screen and power cables from damage and is easily accessible for future changes to the AV setup.

A wide range of mounting options are available to suit different screens and speaker arrangements.

The Heavy Duty Flap Actuator mechanism eliminates the need for a lid or box to be mounted around the screen.

The Telescopic Unit allows the screen to be lifted a further 575mm [22.6], producing a Maximum Lift Distance of 1315mm [51.8].

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 2 of 9

Page 3: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

7.9

200

23.6600

A

Screen Cables enter the top of the Telescopic Unit and are fed down through the Cable Track within. This can be accessed by removing the two front covers of the Telescopic Unit. The cables then pass through the LSM Beam and into the LSM Cable Track. Cables must be routed carefully to prevent any interference with the LSM beam as it operates.

Screen and Mechanism cables should be routed to a control box outside of the cabinet via an opening in the back of the cabinet or a conduit leading to the bottom.

Recommended cable exit point

Conduit

CL

To Mains Power

Screen Cables enter the Telescopic Unit here

DETAIL A Cables exit beam and enter cable track

LSM Beam

LSM Cable Track

KK

Maximum Possible Depth of Conduit 38mm [1.5]

TOP VIEW

8.3210

2.052

5.9150

Control Box

Cable Routing

SCREEN CABLEMECHANISM CABLEPOWER CABLE

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 3 of 9

Page 4: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

34.6880

InternalCabinetHeight

0.820

Max Thicknessof Base andCabinet Top

0.820

0.820

Internal Cabinet Width = Screen Width + 180 [7.1]Minimum Width = 1000 [39.4]

51.81315

MaximumLift Distance

2.870

A

A

0.13

0.820

Minimum Distancefrom Screen toEdge of Base

29.1740Max

ScreenHeight

6.1154

5.5141

Back ofMechanism

to Mount

B

SECTION A-A

0.820

Aperture Depth =Screen Depth + 140 [5.5]

Minimum 150 [5.9]Maximum 200 [7.9]

DETAIL B

Flaphingepoint

Mechanism Up - In Cabinet

IMPORTANT: Thicker cabinet tops will require a reduced maximum screen heightwww.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 4 of 9

Page 5: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

34.6880

InternalCabinetHeight

0.820

MaximumThickness

of Base andCabinet Top

5.5140

Minimum ScreenHeight from Base

of Cabinet 0.820

0.410

Minimum Distancebetween Screenand Cabinet Top

B

B

Aperture Width =Screen Width +46mm [1.8]

Aperture Depth =Screen Depth + 140 [5.5

Minimum 150 [5.9]Maximum 200 [7.9]

Maximum Flap Weight 5Kg [11Ibs]

29.1740Max

ScreenHeight

6.5165

5.5141

Back ofCabinet to

Mount

SECTION B-BIMPORTANT: Thicker cabinet tops will require a reduced maximum screen height

Mechanism Down - In Cabinet

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 5 of 9

Page 6: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

Flap Panel Width = Cabinet Aperture Width -6mm [0.25]

FLAP PANEL - BOTTOM VIEW

HINGE SIDE

Base Panel Width = Cabinet Aperture Width -6mm [0.25]

15.7400

3.590

3.0

75

0.820

BASE PANEL - TOP VIEW

Cut-out for HF Push Rod

VIEWING SIDE

VIEWING SIDE

CL

0.820

Base Panel Depth =Cabinet Aperture

-34mm [1.34]Minimum 116mm [4.6]Maximum 166mm [6.5]

Flap Panel Depth =Cabinet Aperture

-6mm [0.25]Minimum 144mm [5.7]Maximum 194mm [7.6]

M

0.12

0.410

0.410

DETAIL M

Base Panel and Flap Panel DetailsFlap depth dimensions are based on a 3mm thick piano hinge

Required flap dimensions may vary dependant on the hinge used

IMPORTANT: Flap Panel weight must not exceed 5Kg [11Ibs]

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 6 of 9

Page 7: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

41.31050

Highest PossibleCentreline of Mount

15.7400

15.7400

CL

15.7400

11.8300

7.9200

33.9860

Lowest PossibleCentreline of Mount

15.7400

CL

Screen Mount AdjustabilityA standard adjustable height VESA 400 mount is included. This is also compatible with VESA 300 and 200 mounting patterns

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 7 of 9

Page 8: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

D

The Flap Panel is attached to a hinge at the back of the cabinet aperture.

The HF Unit is fixed to the rear face of the cabinet with wood screws.

The LSM is fixed to the back of the cabinet with wood screws in each corner

The outer limits of the travel of the actuator can be adjusted to alter the Open and Closed positions of the Flap.

DETAIL D

The Flap Plate is attached to the under side of the Flap and fixings are concealed with a magnetic Cover Plate

Mechanism Installation Overview

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 8 of 9

Page 9: LSM-TU-HF 5 - TECH ISSUE002cdn.futureautomation.co.uk/Tech/lsm-tu-hf5-tech.pdf · LSM Beam LSM Cable Track K K Maximum Possible Depth of Conduit 38mm [1.5] TOP VIEW 8.3 210 2.0 52

34.6880

17.8451

20.7525

34.6878

BackPlate

Height

6.1154

85.62173

29.3745

32.5826

6.2158

23

.058

5

6.5165

MECHANISM - UP POSITION

MECHANISM - DOWN POSITION

Overall Mechanism Dimensions

www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

LSM TU HF 5 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002

SHEET 9 of 9