ERROR MESSAGES IN MBS
Bracing Error Messages
BR-105 Number of braced bays is greater than MAX_BRC
BR-110 Number of braced bays is greater than number of bays.
BR-115 Bracing in bay with framed opening.
BR-120 Number of attachment points is greater than MAX_ATT
BR-125 Invalid attachment point location. - Location is less than 0.0 - Location is greater than building width
BR-130 Panel not provided, Panel shear not available
BR-135 Bracing member type not available
No panel shear or bracing used.
Building Code Error Messages
BC-105 Wind code must be MBMA, UBC, or SBC - MBMA - UBC - Uniform Building Code - SBC - Southern Building Code
BC-110 Exposure must be B or C. - B - - C -
BC-115 Closure must be O or C - O - open - C - closed
BC-120 Seismic zone range must be between 0 to 4
Bay Spacing Error Messages
BS-105 Number of bays is greater than MAX_BAY
BS-110 Number of bays must be greater than zero.
BS-115 Invalid bay ID - ID is less than 1 - ID is greater than total number of bays
BS-120 Sum of sidewall bay lengths does not equal building length.
BS-125 Sum of endwall bay lengths does not equal building width
Building Layout Error Messages
BL-105 Building type must be FF or LT. - FF - full frame - LT - lean-to
BL-110 Building width must be greater than 0.0
BL-115 Building length must be greater than 0.0
BL-120 Building height must be greater than 0.0
Data Files Error Messages
DA-105 Total number of size is greater than MAX_SIZ
DA-110 Member size not found in data file
DA-115 Number of laps is greater than MAX_LAP
DA-120 Number of laps is equal to zero
DA-125 Lap size not found in data file
DA-130 Lap brace not found in data file
DA-135 Number of cables is greater than MAX_CBL
DA-140 Number of cables is equal to zero
DA-145 Cable size not found in data file
DA-150 Number of panels is greater than MAX_PNL
DA-155 Number of panels is equal to zero
DA-160 Panel size not found in data file
DA-165 Number of flange plate sizes is greater than MAX_FLG
DA-170 Number of plate thickness' is greater than MAX_THK
DA-175 Properties must be greater than 0.0
Design Limits Error Messages
DL-105 Stress yield must be greater than zero
DL-110 Maximum stress ratio must be greater than zero
DL-115 Deflection limit must be greater than zero
Detail Error Message
DT-105 Number of details is greater than 26
DT-110 Detail ID must be in range 'a' to 'z'
DT-115 Invalid detail name
Drawing Option Error Messages
DO-105 Drawing size must be greater than zero
DO-110 Drawing offset must be greater than zero
DO-115 Drawing detail size must be greater than zero
DO-120 Drawing option must be FS or FF - FS - framing & sheeting - FF - frame only
DO-125 Drawing option must be PO or PD - PO - plan only - PD - plan & details
DO-130 Drawing option must be FF, AB, LS, or RS
- FF - full frame
- AB - above and below - LS - left side - RS - right side
DO-135 Drawing option must be S1 ort S2 - S1 - sheet 1 - S2 - sheet 2
End wall Member Error Messages
EW-105 Number of columns is greater than MAX_COL
EW-110 Number of rafters is greater than MAX_RAF
EW-115 Invalid column location - Location is less than zero - Location is greater than building width
EW-120 Member type must be SC, DC, R, or W - SC - single C section - DC - double C section - R - rolled section
- W - welded section
EW-125 Must specify endwall bay spacing with crane systems
Flange Brace Error Messages
FB-105 Total number of flange braces is greater than MAX_BRC
FB-110 Invalid flange brace location Id - ID is less than one
- ID is greater than number of girts/purlins on surface
Framed Opening Error Messages
FO-105 Number of framed openings is greater than MAX_OPN
FO-110 Framed opening width is greater than bay width
FO-115 Opening type must be 1 on endwall
FO-120 Opening type must be 1 or 2 on sidewall
FO-125 Opening offset must be greater than zero on sidewall
FO-130 Opening door height is greater than rafter height
FO-135 Opening door height is greater than eave height
FO-140 Two openings in same bay
FO-145 Opening with no bay spacing
FO-150 Opening offset must be > 0.0 for bypass/outside girt
Input and Output Error Messages
IO-105 Input file not found
IO-110 Trouble reading input file
Loading Error Messages
LD-105 Number of design loads is greater than MAX_DES
LD-110 Invalid auxiliary load Id
LD-115 Total number of auxiliary loads is greater than MAX_AUX
LD-120 Number of load combinations is greater than MAX_CMB
LD-125 Invalid additional load Id
LD-130 Number of additional loads is greater than MAX_ADD
LD-135 Additional load type must be C or U - C - concentrated load
- U - uniform load
LD-140 Selected seismic equation doesn't include Importance.
LD-145 All load coefficients for basic load are 0.00. Additional basic load not combined
into Design Loads.
Partial Wall Error Messages
PW-105 Invalid partial wall height - Height is less than zero - Height is greater than wall height
Roof Purlin Error Messages
RP-105 Purlin type must be CF, ZF, or ZB - CF - flush C section, - ZF - flush Z section, - ZB - bypass Z section
RP-110 Number of purlin rows must be greater than one
RP-115 Purlin spacing must be greater than zero
RP-120 Purlin peak must be greater than zero RP-125 Purlin depth must be greater than zero
Rigid Frame Error Messages
RF-105 Number of different frames is greater than 6
RF-110 Frame section spacing must be greater than zero
RF-115 Number of interior columns must be greater than 0.00
RF-120 Frame spacing must be greater than zero
RF-125 Frame type must be FF or LT - FF - full frame
- LT - lean-to
RF-130 Number of interior columns is greater than MAX_INT RF-135 Column type must be WF, WR, or PI
- WF - rolled W section,
- WR - welded plate section,
- PI - round pipe section
RF-140 Column orientation must be S or R - S - standard
- R - rotated
RF-145 Invalid interior column location - Location is less than or equal to zero
- Location is greater than or equal to the building width
RF-150 Column connection must be P or F - P - pinned
- F - fixed
RF-155 Total number of member depths is greater than MAX_DEP
RF-160 Invalid member depth location
RF-165 Member depth must be greater than zero RF-170 Number of segments is greater than MAX_SEG
RF-175 Number of segments on member must be greater than zero
RF-180 Segment plate size must be greater than zero RF-185 Frame member shape must be C or T
- C - constant depth surface
- T - tapered depth surface
Splice Error Messages
SP-105 Total number of splices is greater than MAX_SPL
SP-110 Invalid splice location - Location is less than zero
- Location is greater than surface length
SP-115 Splice type must be M or P - M - moment
- P - pinned connection (shear)
SP-120 Inadequate column width to accommodate rafter splice plate Rafter peak splice plate is too wide to fit inside endwall column web
Surface Shape Error Messages
SS-105 Number of surfaces is greater than MAX_SRF
SS-110 Invalid surface Id - ID is less than one
- ID is greater than total number of surfaces
SS-115 Surface offset must be greater than or equal to zero
SS-120 Surface extension must be greater than or equal to zero SS-125 Surface extension type must be S or E
- S - standard lapped
- E - extended non-lapped
Wide Opening Error Messages
WO-105 Inadequate frame offset from column. The rafter offset is not enough for the bypass endwall column.
Wall Girt Error Messages
WG-105 Number of girts is greater than MAX_GRT
WG-110 Endwall girt type must be CF or ZF - CF - flush C section,
- ZF - flush Z section
WG-115 Sidewall girt type must be CF, ZF, or ZB - CF - flush C section,
- ZF - flush Z section,
- ZB - bypass Z section
WG-120 Invalid girt location - Location is less than zero
- Location is greater than wall height
- Location is out of order
WG-125 Maximum girt spacing must be greater than zero
WG-130 Girt depth must be greater than zero