40
Leica DMI 3000 M Leica DMI 5000 M Modular system Stands, modules, accessories

Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

  • Upload
    others

  • View
    15

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

Leica DMI 3000 MLeica DMI 5000 MModular systemStands, modules, accessories

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 1

Page 2: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

2

Leica DMI 3000 M/DMI 5000 M Modular system

Issued: August 2008

Contents

Leica DMI Series – Basic stands page 3

System overview page 4

Camera ports page 11

Observation and documentation tubes page 12

Eyepieces page 12

Mot. reflector revolver / Mot. magnification changer page 15

Stages and sample holders page 17

Incident light illumination page 19

Condensers and accessories page 29

Light sources, lamp housing, supply units page 31

TV adapter page 34

Objectives, objective turret, optics page 35

Accessories page 36

System overview page 38

Published August 2008

Leica Microsystems CMS GmbHErnst-Leitz-StraßeD-35578 Wetzlar (Germany)

Responsible for contents:Stefan Motyka(Marketing Industry Division, Product Management)Holger Grasse(Safety Officer according to MPG §30)

In case of technical questions, please contact the hotline:Tel. +49(0)6441-292286Fax +49(0)6441-292255E-mail: [email protected] for questions related to the software:E-mail: [email protected]

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 2

Page 3: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

3

Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of theproven inverted research microscopes for use in industrialapplications. Applications range from routine tasks to researchtasks, quality inspections, material analyses for the developmentof new materials or in quality inspection. All contrasting methodssuch as bright field, dark field, DIC, POL or fluorescence are anintegrated component of the microscope and are quickly andeasily adapted or changed. Variable illumination and imagingbeam paths as well as HCS optics, modular accessories and anextensive peripheral program complement the inverted researchstand Leica DMI 5000 M.

Basic standThe basic stand is the solid core of the microscope. It containsfocusing, objective turret, stage mount, mounts for incident lightor transmitted light illumination units. In addition the DMI 5000 Mfeatures a LCD monitor for status display of the microscope aswell as various function keys for motorized functions, such aschanging magnification, switching camera ports or reflectorsplitter for the different contrasting methods. Interfaces for PCsas well as internal and external peripheral devices are locatedon the back of the basic stand.

The trendsetting modular concept is characterized by theindividual selection of modules, such as light sources, objectives,eyepieces, tubes, stages, filters as well as incident light andtransmitted light components. This allows every user to combinehis or her personal application-orientated microscope system.

The exploded view (see page 38) provides an overview of thismodular system. With their PC-based "e-Leica" configurationsystem, our representatives can provide you with effectivesupport in putting together the optimal system for your require-ments. In addition, our applications specialists in Wetzlar canhelp you with specific questions.

Thanks to its modular design principle, you can modify and/orextend your system to suit your requirements at any time.

Ergonomic considerations were given a high priority in all standvariants, which particularly applies to important controls that arealways designed for easy reach and operation.

The massive, functional and rugged design of the stands ensuresease of use and image stability over the course of the applicationand right up to the highest magnification.

Optics of the highest standards allows for brilliant images withhigh contrast and resolution for any conceivable application.

Fig. 3: Right side of stand DMI 5000 M

Fig. 4: Left side of stand DMI 5000 M

Fig. 2: Front view of stand DMI 5000 M

Fig. 1: Right side of stand DMI 3000 M

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 3

Page 4: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

4

Leica DMI 5000 M1. Basic stands / tubes p. 6, 72. Focusing drive p. 63. Objective turret p. 32–354. Stages p. 13–155. Reflectors p. 16–236. Lamp housings p. 26–297. Ports p. 9

1.

4.

3.

2.

5.

6.

7.

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 4

Page 5: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

5

8. Filter p. 209. Illumination manager p. 710. Contrast manager p. 711. DIC p. 19–2212. Magnification changer (in the stand) p. 6, 713. Status display p. 714. Magnification changer (operation) p. 1015. Camera port switch-over p. 916. Method changeover p. 7

8.

9.

10.

11.

12.

13.

14.15.

16.

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 5

Page 6: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

6

A Leica DMI Microscope stand is defined as a combination of11888xxx article numbers such as:• microscope body• optic carrier• camera ports• incident light module and magnification changers• transmitted light arms• front modules• etc.

Those 11 888 xxx article numbers always come as a integral partof the aligned complete system. These articles are not possibleto order as an individual component.

3 basic stands are available for the Leica DMI “M” Series

Leica DMI 3000 M Manual inverted stand

Leica DMI 5000 M Inverted stand with manual focus drive

Leica DMI 5000 M Inverted stand with motorized focus drive

Dimensions and WeightsWeights: (without CTR BoxLeica DMI series incident light configuration, complete with lamp housing and tube approx. 19 kg

Technical DataOperating voltage: 90–250VFrequency: 50/60 HzPower consumption: P max: 180 WOperating temperature: 10 °C–36 °CRelative humidity: 0–80% at 30 °C

265m

m

126mm

268mm 151mm

410-

510m

m

633mm

665m

m

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 6

Page 7: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

7

All basic stands are ready for:Incident-light examination in:• Bright field• Dark field• Polarization contrast• Differential interference contrast (ICR)• FluorescenceTransmitted-light examination in:• Bright field• Dark field• Polarization contrast• Differential interference contrast (ICT)• Phase contrast

Objective turretManual for Leica DMI 3000 MMotorized and coded for Leica DMI 5000 M• 5-fold for objectives with M32 thread and 45 mm parfocal

distance• For DIC, motorized (manual for DMI 3000 M) / coded Wollaston

prism carousel

Z focus (focus hand wheels on both sides)Manual for Leica DMI 3000 MManual for Leica DMI 5000 MMotorized and coded for Leica DMI 5000 M• 9 mm travel (1 mm below, 8 mm above the stage)

Leica DMI 5000 M only• 5 focus steps: 0.05 µm; 0.1 µm; 0.7 µm; 1.5 µm; 5.0 µm• Electronic focus repositioning• Automatic lowering prior to objective change• Electronic parfocality

Note: Control elements see page 8

The Camera PortsAll Leica DMI 3000 M are ready for:• manual left camera port (80%)• optional manual top port (Fig. 5 p. 7)

with 100/0% and 0/100% eyepiece/port split or with 100/0% and 50/50% eyepiece/port split

All DMI 5000 M stands are ready for: • motorized right camera port

with (100%) and/or (80%) and/or (50%)• motorized left camera port

with (100%) and/or (80%) and/or (50%)• motorized right and left camera port

with (100%) and/or (80%) and/or (50%)• manual top port

with 100/0% and 50/50% eyepiece/port split

Fig. 5: Tube with top port

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 7

Page 8: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

8

Magnification changerAll DMI 5000 M stands are ready for: A motorized magnification changer with 1–3 different, freely-configurable magnification levels affecting all camera ports:• 1.0x (always available)• 1.5x• 1.6x• 2.0x

Alternatively, manual for DMI 3000 MAll basic stands are ready for a manual magnification changerwith two positions. This magnification changer affects only thetop port and eyepieces:• 1.0x (always available)• 1.5x • 2.0x

Electronical control elements (not for DMI 3000 M) (Fig. 6, 7, 8 p. 8)• 7 fixed control buttons for illumination and apertures• 7 variable function buttons behind the focus controls• 3 fixed control buttons for focus thresholds

(for DMI 5000 M stand with motorized focus)• 2 focus hand wheels• 5 buttons for reflector cube and shutter• 4 buttons for motorized magnification changers and ports• SmartMove: ergonomic controller for x, y, z and 4 additional

variable function buttons (Fig. 15 p. 10)Leica STP6000: external controller for x, y, z and 11 additionalvariable function buttons (Fig. 16 p. 10)

Interfaces (not for DMI 3000 M) (Fig. 9 p. 8)• 2 x RS232C• 2 x USB• 4 x external/internal peripherals

Tubes (Fig. 19, 20, 21 p. 12)• Fixed Bino Tube• Ergonomic tube with or without camera port at left. Height and

angle adjustment (30°–45°)• 2 switch settings: 100% VIS and 50% VIS/50% camera or 100%

VIS and 0%VIS/100% camera• Eye spacing adjustment• Field number: 25 mm• Viewing channel

Optics• Leica HCS infinity optics• Tube factor 1x• 25 mm field of view

Fig. 9: Back panel

Fig. 6: Controls (left) DMI5000 M

Fig. 7: Controls (right) DMI5000 M

Fig. 8: Controls (front)DMI5000 M

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 8

Page 9: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

9

Motorized incident-light axis for DMI 5000M (Fig. 18 p. 11)• Automatic Illumination Manager (aperture, field diaphragm,

intensity, contrast method switching)• Automatic constant color intensity control (CCIC)• Lamp housing mount for up to 3 interchangeable light sources• Motorized 4x reflector revolver

Manual transmitted-light axis (Fig. 61, 62 p. 27)• With Condenser Quick Changer for all condensers• Manual field diaphragm• Manual shutter• Manual filter switching• Lamp housing mount for interchangeable lamp housings• Automatic, electronic condenser identification

Stages (p. 17)• Fixed regular stages

– Ceramic-coated stage plate (248 mm x 204 mm)

• Manual 3-plate stage (page 18)Positioning range 100 mm x 40 mm– Optionally different inserts for various applications, dimen-

sions of inserts: outside 160 mm x 110 mm (compatible withmotorized stages); rated inside diameter 5 mm, 10 mm, 20 mm and 40 mm

• Motorized 3-plate stage (page 18)– Positioning range 100 mm x 40 mm– Optionally different inserts for various applications, dimen-

sions of inserts: outside 160 mm x 110 mm (compatible withscanning stages and manual stages); rated inside diameter5 mm, 10 mm, 20 mm and 40 mm

• Scanning stage IM 100 x 40 (p. 18)– Both motors below stage– 1 mm, 2 mm, 4 mm spindle rise (higher resolution vs. higher

speed)– Optionally different inserts for various applications, dimen-

sions of inserts: outside 160 mm x 110 mm (compatible with 3-plate stages); rated inside diameter 5 mm, 10 mm, 20 mm and40 mm

Fig. 12: Incident-light axis illumination

Fig. 10: Viewing channel

Fig. 11: Transmitted-light illumination arm

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 9

Page 10: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

Stand variants3 basic stands are available for the DMI 3000 M/DMI 5000 M.These basic stands differ essentially by a motorized or a manualfocusing drive.DMI 3000 M basic stand with manual focus (Fig. 1 p. 3) (with manual DIC turret) 11 888 730DMI 5000 M basic stand with manual focus (Fig. 3 p. 3) (with manual or motorized DIC turret) 11 888 725DMI 5000 M basic stand with motorized focus (Fig. 4 p. 3)(with manual or motorized DIC turret) 11 888 724

Electronics boxes (Fig. 13,14 p. 10)With built-in power supply 12 V 100 W and for control of theautomatic microscope functions. With interface RS 232 for PCconnection including RS 232 cable. AC power supply 90–250 V,50–60 Hz

SmartMove (Fig. 15 p. 10)x/y/z-ergo control for the control of the electronic focus (z) andmotorized stage (x/y). With 4 additional freely programmablefunction keys. 11 505 180

Leica STP6000 (Fig. 16 p. 10)External Touch Panel for electronic focus (z) and motor stage(x/y). With 11 freely programmable function keys. 11 501 255

10

Z-driveman.

Z-drivemot.

Stagemanual

StageTack

StageScanning

CTR400011 888 164

x x

CTR600011 888 821

x x

CTR650011 888 822

x x x

Fig. 15: Leica SmartMove

Fig. 16: Leica STP6000

Fig. 14: Leica CTR6500

Fig. 13: Leica CTR4000

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 10

Page 11: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

Observation and Documentation PortsCamera ports for Leica DMI 3000 M The Leica DMI 3000 M can be equipped with a manual leftcamera port which features a mechanical slider with twopositions.1st position for 100 % light to the eyepieces.2nd position percentage of light to the side port rest to eyepiecesTwo choices are available:Manual left camera side port 100/0 11 888 389Manual left camera side port 80/20 11 888 388

Camera ports for Leica DMI 5000 MThe DMI 5000 M can be fitted with different camera ports.The manual top port is selected together with the tube (see p. 12). Select the motorized side ports with the followingmodules:

Motorized side port, left only 11 888 391In addition, up to three different prisms are selected for this variant:• Side port prism, 100% left 11 888 259• Side port prism, 80% left 11 888 262• Side port prism, 50% left 11 888 264

Motorized side port, right only 11 888 392In addition, up to three different prisms are selected for this variant:• Side port prism, 100% right 11 888 258• Side port prism, 80% right 11 888 261• Side port prism, 50% right 11 888 263

Motorized side port, right and left 11 888 393In addition, up to three different prisms are selected for this variant:• Side port prism, 100% right 11 888 258• Side port prism, 100% left 11 888 259• Side port prism, 80% right 11 888 261• Side port prism, 80% left 11 888 262• Side port prism, 50% right 11 888 263• Side port prism, 50% left 11 888 264

No side port 11 888 256This variant requires the port compensation module

11

Fig. 18: 4x reflector revolver and motorized magnification changer

Fig. 17: Light Path

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 12:26 Uhr Seite 11

Page 12: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

Observation and documentationtubesThe Leica DMI microscopes feature a fixed bino tube andseveral ergonomic tubes integrated in the stand. The interpupil-lary distance can be adjusted according to the Siedentopfprinciple. The complex tube lens system is based on an infinitebeam path. It converges the parallel beam path coming from thelens and forms the object in the intermediate image plane. Also,the tube lens system, together with the eyepieces, corrects theremaining image errors not corrected by the objective. The following applies to all tubes:Siedentopf designField of view 25 mmEyepiece diameter 30 mmInterpupillary distance range 55–75 mmViewing angle 45° (Fix tube)Variable viewing angle 30–45° (Ergo tubes)View chute to observe samples without eyepieces

Binocular fix tubeBinocular fix observation tube 11 888 373

Binocular ergonomical tube (Fig. 19 p. 11)Binocular observation tube 11 888 372

Trinocular ergonomical tube (Fig. 21 p. 11)Binocular observation tube with manually switchable sidecamera port and variable light path, 100% visual/0% camera,and 0% visual and 100% camera 11 888 324

Trinocular ergonomic tubeBinocular observation tube with side camera port and variablelight path, 100% visual/0% camera, and 50% visual/50% camera

11 888 368

Eyepieces for tube viewing (Fig. 22 p. 11)A wide range of eyepieces with 10x, 12.5x, 16x or 25x magnifica-tion (for different field numbers of up to 25 mm) are available forthe tubes. Special eyepieces for eyeglass wearers are available,as are eyepieces with adjustable eyelenses (M eyepieces)designed to accommodate a variety of graticules. The standardeyepiece is the 10x eyepiece, microphotography recording frequently prefers the 12.5x eyepiece magnification due to thehigher focusing accuracy. However, the observed object field issmaller. The 16x and 25x eyepiece magnifications are onlymeaningful for special cases; exceeding the "beneficial magnifi-cation" (V < 1000x objective aperture) can often be expected, i.e. possible fuzziness may occur.All eyepieces have removable or fold-down eyecups and can beused with or without eyeglasses. Eyepieces identified with Mare equipped with a focusing eyelens for dioptric equalization(from –6.8 to +4.2 or –6 to +5) and graticule holder.

12

Fig. 19: Bino-ergotube

Fig. 20: Siedentopf tube with inter -pupillary distance adjustment

Fig. 21: Trino-ergotube

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 12

Page 13: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

13

The outside eyepiece diameter is D = 30 mm. Graticule diameterD = 26 mm. The eyepiece data are engraved, e.g. HC PLAN10x/20 oo M. HC PLAN = correction type, 10x = magnification/20 = field number FOV, oo = for eyeglass wearers (high exit pupil), M = dioptric adjustment/graticule holder

Eyepieces with FOV 20• Eyepiece HC PLAN 10x/20 BR. 11 507 801• Eyepiece HC PLAN 10x/20 BR.M 11 507 802

Eyepiece with FOV 22Eyepiece HC PLAN S 10x/22 Br.M 11 507 807

Eyepiece with FOV 25Eyepiece HC PLAN S 10x/25 Br.M 11 507 808

Special eyepieces with high magnification• Eyepiece HC PLAN 12.5x/16 Br.M 11 506 515• Eyepiece 16x/14B, adjustable 10 445 301 • Eyepiece 25x/9.5B, adjustable 10 445 302 • Distance ring for eyepieces 16x/14 B and eyepiece

25x/9.5B 11 506 808

Photo eyepieces, eyepiece tubes, focusing and framing graticulesThe adaptation of microphotography equipment requires anexactly matched combination of photo eyepiece, eyepiece tubeand focusing and framing graticule. The focusing and framinggraticule is inserted in an HC PLAN M observation eyepiece andshows the respective imaging format. In addition, the graticulefeatures focusing marks for exact focusing.

For 10x photo eyepiece• Eyepiece tube HC DR 27/10x for MPS 11 541 514• Eyepiece HC 10x/16 Photo 11 541 501• Focusing and framing graticule F6, 26 mm 11 506 961

For 8x photo eyepiece• Eyepiece tube HC DR 27/8x for MPS 11 541 513 • Eyepiece HC 8x/20 Photo 11 541 500 • Focusing and framing graticule F5, 26 mm 11 506 960

For 12,5x photo eyepiece• Eyepiece tube HC DR 27/12,5x for MPS 11 541 515 • Eyepiece HC 12.5x/13 Photo 11 541 535• Focusing and framing graticule F8, 26 mm 11 506 963

Fig. 23: Photo eyepieces

Fig. 22: Eyepieces

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 13

Page 14: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

14

Graticules for length measurements, comparison andcounting methodFor HC PLAN eyepieces• Graticule 10 mm = 100 parts, D = 26 mm 11 506 950 • Graticule 10 mm = 200 parts, D = 26 mm 11 506 951 • Crosshair graticule, D = 26 mm 11 506 953• Crosshair graticule with graduation,

10 mm = 100 parts, D = 26 mm 11 506 952• Graticule with grid 10 x 10 mm,

0.1 mm graduation, D = 26 mm 11 506 954• Graticule with grid 10 x 10 mm,

1 mm graduation, D = 26 mm 11 506 955• Snyder-Graff-Meth. graticule, D = 26 mm

(for 10x eyepiece only) 11 566 950• ASTME 112 graticule, D = 26 mm

(for 10x eyepiece only) 11 566 951• Graticule for steel inclusion rating (ISO 4967) 11 102 133• Graticule for steel inclusion rating (EN10247) 11 102 134

Stage micrometer• Transmitted light 2 mm = 200T, glass carrier with scale

1 scale interval = 10 µm 11 513 106• Incident light 10 mm = 100T

for overview objectives (e.g. 1.25) 11 519 963

0

1

2

3

4

5

6

7

8

9

10

Graticule 11 102 133

Graticule 11 102 134

Graticule 11 506 950 Graticule 11 506 951 Graticule 11 506 952 Graticule 11 506 953

Graticule 11 506 954 Graticule 11 506 955 Graticule 11 566 950 Graticule 11 566 951

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:38 Uhr Seite 14

Page 15: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

15

Motorized reflector revolver/motorized magnification changerUp to 4 reflector filter blocks on the reflector turret contain aperfectly matched combination for all standard contrast methodsin material analysis. The disk is integrated in the stand and iswithin the DMI5000 M stands fully motorized and coded. If thecontrast method is changed, the filter blocks are switched in lessthan 0.2 sec.A locking button releases the disk in a drawer for easy, conve-nient filter replacement within seconds, without tools.2 reflector filter blocks feature spring clamps for engaging in theincident-light revolver, filter blocks are firmly screwed into theother two positions. The optional motorized magnification changer is located on thereflector revolver. In addition to the 1x tube lens, two furthermagnification levels can be introduced here on an additional diskwith 3 positions. This motorized magnification changer acts onthe right as well as the left camera port as well as the tube and, ifnecessary, the top port.

Motorized 4x reflector revolver (as in Fig. 24 p. 15)• with fixed 1x tube lens (no additional lenses

can be inserted)• with mount of up to 4 reflectors 11 888 727

Motorized 4x reflector revolver with mot. magnification changer(Fig. 24, 25 p. 15)• with mount of up to 4 reflectors• with motorized magnification changer

including 1x tube lens at position 1 11 888 726

Magnification levels for the manual magnificationchanger of DMI 3000 MThis magnification chnager affects the top port and the eye-pieces.• 1.5x tube lensfor manual magnification changer 11 888 732• 2.0x tube lensfor manual magnification changer 11 888 733

Magnification levels for the motorized magnificationchanger of DMI 5000 MIn addition to the 1x tube lens, one or two magnification lensescan be installed on the disk.• 1.5x tube lensfor motorized magnification changer 11 888 699• 1.6x tube lensfor motorized magnification changer 11 888 377• 2.0x tube lensfor motorized magnification changer 11 888 376

Fig. 24: 4x reflector revolver and motorized magnifi-cation changer

Fig. 25: 4x reflector revolver and motorized magnifi-cation changer

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 12:26 Uhr Seite 15

Page 16: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

16

Leica CTR BoxesLeica CTR4000 Electronics Box (Fig. 26 p. 16)Power supply for 12 V 100 W. AC power supply 90–250 V, 50–60 Hz.For all stands without motor focus and without motorized stages 11 888 164

Leica CTR5500 Electronics BoxWith built-in power supply 12 V 100 W and for control of theautomatic microscope functions. With interface RS232 for PCconnection including RS232 cable. AC power supply 90–250 V, 50–60 Hz. For all stands with motor focus and all stands without motorizedstage (for fixed stage and manual stages only) 11 888 820

Leica CTR6000 Electronics Box With built-in power supply 12 V 100 W and for control of theautomatic microscope functions. With interface RS232 for PCconnection including RS232 cable. AC power supply 90–250 V, 50–60 Hz.For all stands with motor focus and all stands with motorized 3-plate stages (rack) 11 888 821

Leica CTR6500 Electronics Box (Fig. 27 p. 16)With built-in power supply 12 V 100 W and for control of theautomatic microscope functions. With interface RS 232 and USBconnection including cables. AC power supply 90–250 V, 50–60 Hz. For all stands with motor focus and all stands with a motorizedscanning stage (spindle) 11 888 822

SmartMove (Fig. 28 p. 16)x/y/z-Ergo control panel for electronic focus (z) and motor stage(x/y). With 4 freely programmable function keys. 11 505 180

Leica STP6000 (Fig. 29 p. 16)External Touch Panel for electronic focus (z) and motor stage(x/y). With 11 freely programmable function keys. 11 501 255Fig. 28: Leica SmartMove

Fig. 29: Leica STP6000

Fig. 27: Leica CTR6500

Fig. 26: Leica CTR4000

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 16

Page 17: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

17

Stages and sample holdersA variety of stages is available for the Leica DMI 3000 M andDMI 5000 M. Depending upon the application, the followingstages can be selected: • Fixed stage (248 x 204 mm)• Manual 3-plate stage, positioning range 100 x 40 mm• Motorized 3-plate stage, positioning range 100 x 40 mm• Scanning stage 100 x 40 (motors on bottom)

Fixed stage (Fig. 30 p. 17) 11 522 078The 20-mm high stages are solidly attached to the microscope by3 screws, an attachable object guide can be mounted either onthe right or the left. Size 248 x 204 mmAluminum, black anodized, extremely scratch resistant, precision plane-parallel. Mount options for 88-mm round insertswith openings of 5 mm, 10 mm, 20 mm and 40 mm (see inserts formanual and motorized stages, a round 88 mm insert with 10 mmopening is included).Bores on the left and right side for the adaptation of attachableobject guides.

88 mm Inserts with different openings for fixed stages and 160 x 110 mm inserts for 3-plate stages and scanning stages• Insert with 5 mm opening 11 522 083• Insert with 10 mm opening* 11 522 084 • Insert with 20 mm opening 11 522 085• Insert with 40 mm opening 11 522 086

*) Insert with 10 mm opening is already included in stages

Attachable object guide for fixed stages (Fig. 31 p. 17) (for 11 522 078)Attachable mechanical object guide for fixed working stage toaccept different application inserts. Attachable to the fixed stageeither on the right or the left. Positioning range: 100 mm x 40 mmErgonomic operating arm: low position, does not interfere withmicroscope controls or camera ports, with coaxial drive for x and y. Adjustable torque, extremely precise and sensitive. Wear-resistant ceramic bearing surfaces in x and y.Z positioning precision adjustable over the positioning range.Precise snap-in mechanism for a variety of inserts.Integrated scaling in x and y (optional for a number of inserts)

11 522 014 Inserts for object guide 11 522 014The mounting frames are inserted into the attachable mechani-cal stage via a precise snap-in mechanism. Material: aluminum,black anodized.• Universal mounting frame M glass slide 11 520 688• Universal mounting frame M duo for 2 glass slides 11 531 798• Mounting frame for glass slide 76 mm x 26 mm 11 520 593

Fig. 30: Fixed stage

Fig. 31: Attachable mechanical stage

Fig. 32: Universal mounting frame M

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 17

Page 18: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

18

Manual 3-plate-stage (without insert) (Fig. 33 p. 18)Traveling range: 100 mm x 40 mmAluminum, extremely scratch-resistant, precisely plane-parallelfor 160 x 110 mm inserts.Ergonomic operating arm: low position, does not interfere withmicroscope controls or camera ports, with coaxial drive for x and y. Adjustable torque, extremely precise and sensitive. Three-point mounting. 11 522 604

Motorized 3-plate-stage (without insert) (Fig. 34 p. 18)Traveling range: 100 mm x 40 mmAluminum, extremely scratch-resistant, precisely plane-parallelfor 160 x 110 mm inserts.Control via the Leica Application Suite software in conjunctionwith the SmartMove remote control (see Fig. 28 p. 16) or STP6000(see Fig. 35 p. 18)Extremely precise and sensitive.Three-point mounting. 11 522 603

Cable adapterUsing a 3-plate stage in combination with a Leica CTR6500electronic box an adapter is necessary 11 505 237

Scanning stage 100 x 40 (without insert) (Fig. 34 p. 18)3-plate scanning stage without insertTraveling range: 100 mm x 40 mmThree-point mounting.Aluminum, extremely scratch-resistant, precisely plane-parallel for 160 x 110 mm inserts.Max. positioning speed: 10 mm/sec. to 100 mm/sec.*Max. resolution: 0.02–0.04 µm*Reproducibility: <1 µm*Precision: ± 3 µm**) Depending upon built-in spindle: 1 mm, 2 mm or 4 mmWith motors on bottom 11 522 602

Prerequisites for scanning stages• Leica SmartMove for DM/DMI series 11 505 180or• Leica STP6000 11 501 255• Leica CTR6500 electronics box incl. cable

for scanning stage 11 888 822

Inserts for manual and motorized stages (Fig. 36 p. 18)3-plate stages and scanning stages are ready to accept insertswith outside dimensions of 160 x 110 mm. Depending upon thespecimen size, the following inserts can be selected:• Mounting frame for round inserts (160 x 110 mm) 11 522 063

• Insert with 5 mm inside diameter 11 522 083• Insert with 10 mm inside diameter 11 522 084• Insert with 20 mm inside diameter 11 522 085• Insert with 40 mm inside diameter 11 522 086

• Universal retaining frame LK for 1 glass slide 11 600 186• Universal retaining frame LK duo for 2 glass slides 11 531 820

Fig. 33: Manual 3-plate-stage

Fig. 34: Scanning stage 100 x 40

Fig. 36: Mounting frame (160 x 110 mm) with insert

Fig. 35: Leica STP6000

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 18

Page 19: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

19

Incident light illuminationThe Leica DMI “M” series is a system microscope for thefollowing incident-light methods in materials testing and materials research: Bright field, dark field, polarization contrast,interference contrast (ICR) and fluorescence. In addition obliqueillumination is integrated in the DMI 3000 M.With the Leica DMI 5000 M routine functions such as the adjust-ment of intensity and incident-light diaphragms to the objectivemagnification and specimen conditions are automated and offeroptimal working comfort.The incident-light axis of the Leica DMI “M” series is equippedwith a completely new incident-light system. Optimal light fluxwith the greatest intensity and homogeneity is generated. Thefield and aperture diaphragms can be centered and allow for anoptimal Köhler illumination. The result is the best possibleresolution, contrast and depth of field.Different lamp mounts and mirror housings (up to 3 ports) evenallow for illumination from several light sources. A lamp housingcan be used for the incident-light contrast methods bright field,dark field, polarization contrast and interference contrast whileanother lamp housing can be adapted for fluorescence. The regular incident fluorescence illumination is based on high-intensity high-pressure 100 W mercury burners (Hg 100 W) withemission in the short-wave spectral range. Furthermore xenonlamps (XE 75 W) are used when a broadband spectrum range isto be covered.

Up to 4 reflector filter blocks on the reflector turret contain aperfectly matched combination for all standard contrast methods. The disk is integrated in the stand and is fully motorizedand coded. The Leica DMI 3000 M is equipped with a manualreflector turret. If the contrast method is changed, the filterblocks are switched in less than 0.2 sec.A locking button releases the disk in a drawer for easy, convenient filter replacement within seconds, without tools.2 reflector filter blocks feature spring clamps for engaging in theincident-light revolver, filter blocks are firmly screwed into theother two positions. The filter blocks used for fluorescence are designed to guaran-tee zero pixel shift and completely suppress stray light to ensurea completely black background for the fluorescent image.A laterally attached adjustment window together with thesupplied adjustment tool allows for a perfect setting of the lamp.

Fig. 37: Filter block mount

Fig. 38: Opening the drawer

Abb. 39: Exchange filter cubes DMI 3000 M

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 19

Page 20: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

20

Reflectors, filters, incident-lightpolarizers and analyzersThe incident light illuminator is based on a 12 V, 100 W halogenbulb whose luminous intensity is automatically adjusted afterpresetting to the reflection of the specimen and the light flow inthe respective objective.Caution: Adaptation with incident light of the DMI 5000 M is color-neutral: The constant color intensity control (CCIC) integrated inthe incident-light axis of the DMI 5000 M allows for light adapta-tion without the interfering reddish image backgrounds ofconventional systems. Up to 4 reflectors of size k can be used in the reflector turret ofthe Leica DMI “M” Series. The following filter blocks can beselected for the respective contrast methods:

Incident-light bright fieldWith the push of a button on a DMI 5000 M, the BF reflector or theSmith reflector are rotated into the beam path. The motorizedcoded objective turret recognizes the objective and automatical-ly adjusts luminous intensity, incident light aperture and fielddiaphragm to the preset values. The user can adjust and over-write the preset values at any time. Objective magnifications1.25x–150x (1.25x and 1.6x with glint-protection device). Allincident-light functions of a DMI 3000 M are carried out fullymanual.Two different bright field reflectors are available that differaccording to the adaptation in the reflector disk:

BF reflector, fixed (without illustration)Bright-field reflector that is screwed into the reflector disk,already adapted at the factory. 45° neutral glass insert divider for incident-light bright field, ICR and pol. 11 888 716

Optional:BF reflector, variable Bright-field reflector that can be inserted in one of the twovariable positions of the reflector disk. 45° neutral glass insertdivider for incident-light bright field, ICR and pol. 11 571 016

Optional:Gray filter N16 Insertable on BF reflector for light reduction when working withexternal light sources. 11 565 016

Optional:P reflector to Smith (Fig. 41 p. 20)Firmly adapted at the factory, mirror and glass insert divider 2 x 22.5° with lens for incident-light bright field, ICR and POLcontrast.High degree of polarization, especially well suited for ICR andpolarizing incident light. 11 555 081

Fig. 40: Bright-field reflector (BF)

Fig. 41: P reflector to Smith

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 20

Page 21: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

21

Incident-light dark fieldWith a push of the button of the Leica DMI 5000 M, the DFreflector is rotated into the beam path. The motorized codedobjective turret recognizes the objective and automaticallyadjusts intensity, incident light aperture and field diaphragm tothe light values required for dark field. The user can adjust andoverwrite the preset values at any time. Using the DMI 3000 Mthe DF reflector is rotated manually into the beam path.Objective magnifications 5x–150x.

Required:DF reflector, fixed (Fig. 42 p. 21)Adapted at the factory, 45° ring mirror for incident-light dark field. 11 571 015

Incident-light light filter D = 25 mmTwo of the incident-light filters listed below are placed in the ILfilter slide (Fig. 43 a p. 21). The complete filter slide is located inthe filter slot in the rear section of the stand.

IL filter slide (Fig. 44 p. 21)to mount the above light filters D = 25 mm 11 522 028

The following incident-light filters can be selected:• Panchromatic green filterFor B&W photography and sensitivity increase of the eye 11 513 904

• Blue glass filter BG20Color contrast filter for contrast increase 11 513 905

• Daylight filter DLFBlue, conversion filter for daylight film and visualobservation 11 513 906

• Interference green filter VSS 546 nmFor monochromatic light in interferometry 11 513 907

Fig. 44: IL filter slide

Fig. 43 a: Position of incident-light filter slide

Fig. 42: Dark-field reflector (DF)

a

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 21

Page 22: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

22

Incident-light interference contrast (ICR)The manual incident-light interference contrast requires a(rotating) polarizer, an analyzer and a set of Wollaston prisms. Inaddition, the Leica DMI 5000 M offers a fully automated ICRfunction.

The Leica ICR demonstrates its strengths during the analysis ofdefects, for example during the examination of surface struc-tures. Objectives with magnifications from 20x to 100x can beused for ICR. Fast (automatic) switching between ICR, bright fieldand dark field is possible at all times without the need for DICprisms to remain in the beam path. The IC prisms at the objectiveside are located in the objective prism disk (Fig. 46). For validcombinations of prisms and objectives, please refer to theobjective list www.leica-microsystems.com/objectives.

The coded objective turret of the DMI 5000 M knows the objec-tive. The motorized objective prism disk selects the correctobjective prism and sets the bias. The reflector revolver fullyautomatically moves the ICR reflector into the beam path. Inaddition, light intensity, aperture diaphragm and field diaphragmare automatically adjusted to the required values. The user canadjust and overwrite the preset values at any time. If a BF orSmith reflector is used instead of the IRC reflector,the corresponding IC prism must be manually rotated into thebeam path and adjusted.When the manual objective system prism disk is used, the Leicadisplay of the DMI 5000 M shows the information for the requiredprisms.

Manual coded DIC objective system prism disk 11 522 048Motorized coded DIC objective system prism disk(not for DMI 3000 M) 11 522 049

The required incident-light polarizer and analyzer elements canbe supplied on a slider and as an enclosed ICR filter system.

ICT/ICR objective prisms(for assembly in DIC disk 11 522 048 or 11 522 049)

• IC objective prism A 11 555 006• IC objective prism B1 11 555 007• IC objective prism B2 11 555 008• IC objective prism C 11 555 009• IC objective prism C1 11 522 038• IC objective prism C2 11 522 039• IC objective prism D 11 555 010• IC objective prism D1 11 555 056• IC objective prism E 11 555 046

Fig. 45: DIC disk and POL slides under objectiveturret

Fig. 46: Motorized DIC objective prism disk

Fig. 48: Objective prism D

Fig. 47 a: Position of analyzer slider

a

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 22

Page 23: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

23

Condenser prisms (Ø 32mm) for DIC dark field• IC condenser prism K2 11 555 016• IC condenser prism K3 11 555 017• IC condenser prism K4 11 555 018• IC condenser prism K5 11 555 019• IC condenser prism K6 11 521 521• IC condenser prism K7 11 521 522• IC condenser prism K8 11 521 523• IC condenser prism K9 11 555 030• IC condenser prism K10 11 521 524• IC condenser prism K11 11 521 529• IC condenser prism K12, oil 11 521 540• IC condenser prism K16 11 522 037

ICR equipment with polarization slider:The polarization mount is located on the left side of the standbelow the objective turret as shown in Fig. 45. The cover for theobjective DIC slider opening is a component of the stand.

• R/ICR polarizer (Fig. 49 p. 23)In slider 29 x 11.5 mm. Fixed orientation 90° (north-south) withMgF2 plate for homogenizing the brightness across the field.Interference contrast is possible only via DIC prism(vignetting is possible). 11 555 001

• L/ICR polarizer (Fig. 50 p. 23)In slider 29 x 11.5 mm. Fixed orientation 0° (east-west) withLambda plate. 180° rotation for activation or deactivationof the Lambda plate for color contrast. 11 555 051

The analyzer slider is located on the right side of the stand belowthe objective turret as shown in Fig. 52. The cover for the objec-tive slider opening is a component of the stand.

• Analyzer, 180° (Fig. 51 p. 23)In slider 30 x 5 mm, rotating 180° with drum head graduation of 5°, 1 scale line = 5° 11 522 062

• Analyzer, ICT/P (Fig. 52 p. 23)In slide bar 30 x 5 mm, fixed orientation 90° 11 522 046

Alternative:• Filter system for fully automated ICR (Fig. 53 p. 23)For quick and convenient operation.Neutral splitter with permanently installed and fixedly crossedpolarizer and analyzer and MgF2 plate for homogenizing thebrightness over the field. For use in the reflector disk.Interference color contrast is possible only via DIC prism (vignetting is possible). 11 513 901

Fig. 50: L/ICR polarizer

Fig. 49: R/ICR polarizer

Fig. 51: Analyzer, 180°

Fig. 52: Analyzer ICT/P

Fig. 53: ICR filter block with firmly crossed polarizerand analyzer

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 23

Page 24: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

24

Incident-light polarization contrastA fixed or revolving polarizer and an analyzer are required forincident-light polarization contrast. Low-stress objectives andcondenser lenses are a requirement for optimal quality of thepolarization contrast.Instead of polarizer and analyzer as single slider, it is alsopossible to use complete polarization filter systems if the examination does not require a revolving polarizer. They consistof a neutral divider with firmly crossed polarizers.

P reflector to Smith (Fig. 54 p. 24)Firmly adapted at the factory, mirror and glass insert divider2 x 22.5° with lens for incident-light bright field, ICR and polarizercontrastHigh degree of polarization, especially well suited for ICR andpolarizing incident light. 11 555 081

Pol. filter system, IGS (Fig. 55 p. 24)Reflector (size k) consisting of polarizer and analyzer in firmlycrossed position. 11 513 898

R/P polarizer (Fig. 56 p. 24)In slider 29 x 11.5 mm. Changeable in 3 click stops 0° (east-west),45° (diagonal), 90° (north-south). 11 555 005

Alternative:Polarizer, revolving (Fig. 57 p. 24)In slider 29 x 11.5 mm. Polarizer revolution 90°, Lambda platerevolution approx. 14°. For color contrasting of anisotropicmaterial surfaces, e.g. aluminum (sensitive tint method).

11 565 001

Fig. 56: R/P polarizer

Fig. 57: Polarizer, revolving

Fig. 55: Pol. filter system, IGS

Fig. 54: P reflector to Smith

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 24

Page 25: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

25

Michelson/Mirau incident-light interference deviceSurface analyses with accuracies in the range of a few nanometers are performed at the DMI 5000 M with the Michelson/Mirau mount. The exact and quick measurement offilters in the optical industry or the analysis of polished surfacesare application areas of this non-destructive analysis system.This requires the following:

5x, Michelson 11 565 020consisting of:- PL FLUOTAR 5x/0.15 Michelson objective- 5x Michelson dual-beam mount- Base structureAdapter ring M32/25 11 561 003

10x, Mirau 11 565 021consisting of:- PL FLUOTAR 10x/0.30 Mirau objective- 10x Mirau dual-beam mount - Base structureAdapter ring M32/25 11 561 003

20x, Mirau 11 565 022consisting of:- N Plan H 20x/0.40 Mirau objective- 20x Mirau dual-beam mount - Base structureAdapter ring M32/25 11 561 003

50x, Mirau 11 565 023consisting of:- N Plan H 50x/0.50 Mirau objective- 50x Mirau dual-beam mount - Base structureAdapter ring M32/25 11 561 003

Interference green filter VSS 546 (25 mm Ø) for monochromatic light, without mount 11 513 907

IL filter holder for Ø 25 mm filter 11 522 028

Fig. 58: Interference base component

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 25

Page 26: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

26

Incident-light fluorescenceThe incident-light fluorescence of the DMI 3000 M/DMI 5000 M isequipped with a completely new incident-light system. Differentlamp housings and mirror housings (up to 3 ports) that can beadapted to DM 3000 M/DM I 5000 M also allow for simultaneousillumination with several light sources (lamp housings see p. 31).Optimal light flux with the greatest intensity and homogeneity isguaranteed. Light traps and the suppression of natural fluores-cence result in an optimal black background. The regular inci-dent fluorescence illumination is based on high-intensity high-pressure 100 W mercury burners (Hg 100 W) with emission in theshort-wave spectral range. Furthermore, xenon lamps (XE 75 W)are used when a broadband spectrum range is to be covered.The incident-light axis of the Leica DMI 5000 M is equipped withmotorized light stop which is activated with the push of a buttonor via software to prevent specimens from bleaching.2 additional fluorescence filter blocks on the reflector turret canbe used in addition to the reflector cubes described on page 16.A locking button releases the disk in a drawer for easy, conve-nient filter replacement within seconds, without tools. Switchingfilter blocks is done in less than 0.2 sec.The filter systems (blocks) feature spring clamps for engaging inthe incident-light revolver. All blocks are designed so that theyguarantee a zero-pixel shift and completely suppress possiblestray light with a special design so that the background of thefluorescence image appears completely dark.A selection of common fluorescence filters for materials analy-sis follows below. Additional fluorescence filters can be foundon: http://www.leica-microsystems.com/filtercubes

• Filter system A 11 513 873

• Filter system A4 11 513 874

• Filter system D 11 513 875

• Filter system E4 11 513 876

• Filter system I3 11 513 878

• Filter system N2.1 11 513 882

• Filter system N3 11 513 883

• Filter system B/G/R 11 513 886

• Filter system CFP 11 513 892

• Filter system YFP 11 513 893

Fig. 59: Fluorescence filter system A4

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 26

Page 27: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

27

Transmitted-light illuminationThe mount for the transmitted-light illumination arm is a fixedcomponent of the Leica DMI 3000 M/DMI 5000 M basic stand.Pressing the IL/TL key switches from incident-light to transmit-ted-light illumination in less than 1 second.The transmitted-light arm as well as the condenser and filter areordered separately. The transmitted-light illumination unitessentially consists of an illumination and condenser carrier.Its excellent light utilization is ensured by replaceable Leica lamphousings and optimized aspherical collectors. Optimal andhomogenous illuminated areas are a requirement for all transmit-ted-light contrasting methods, such as bright field, dark field,phase or interference contrast (ICT).The transmitted-light illumination for the DMI 3000 M/DMI 5000 Mconsists of the following components:• Manual, coded transmitted-light illuminator arm (incl. light

filter mount)• Transmitted-light lamp housing• Manual condenser S70/0.30or• Motorized condenser S28/0.55

Manual transmitted light axis (for DMI 3000 M) (Fig. 61 p. 27)for 100 W lamphouseswith integrated tilting mechanism with CQC "Condenser Quick-Changer" for all manual condensers• Manual field diaphragm• Manual shutter• Manual transmitted light filter magazine• Lamp housing mount for interchangeable lamp housings 100W• With integrated duct for the Lamp house cable

11 888 380

Manual transmitted light axis with integrated 30W lamp house(for DMI 3000 M) (Fig. 62 p. 27)with integrated tilting mechanism with CQC "Condenser Quick-Changer" for all manual condensers• Manual shutter• Manual transmitted light filter magazine

11 888 366

Fig. 62: Transmitted light arm 30 W

Fig. 61: Transmitted-light arm

Fig. 60: Lamp mount

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 27

Page 28: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

28

Manual, coded transmitted-light illumination arm (for DMI 5000 M) (Fig. 61 p. 27)Compact transmitted-light illumination arm • with integrated tilting mechanism• with integrated manual field diaphragm • with integrated manual filter magazine for 2 replaceable filter

positions – one position factory-equipped with a shutter• with condenser quick-change• with automatic condenser identification• with standard lamp housing changer for all Leica lamp

housings• with integrated duct for lamp housing cable 11 888 381

Light filter dia. 40 mm, unframed for transmitted-light illumination arm2 transmitted-light filters can be swung in on the manual transmitted-light illumination arms. A broad selection ofdifferent filters is available to optimize illumination for observation and documentation.

• DLF, daylight filter 11 521 577(blue, conversion filter e.g. for daylight film and/or visual observation)

• ALF, artificial light filter (red, correction filter forartificial light film) 11 521 578

• Panchromatic green filter 11 521 582• Neutral filter N 16 (6,3%) 11 521 579• Neutral filter N 4 (25%) 11 521 580• Neutral filter N 2 (50%) 11 521 581• VG 9, narrow band filter 11 521 583

Fig. 63: Stand with transmitted-light illumination arm

Fig. 64: Transmitted-light filter

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 28

Page 29: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

29

Condensers and accessoriesThe Leica DMI 5000 M offers a selection of different condensers.All condensers feature a 7-position condenser disk to accommo-date IC prisms or light rings. They can be individually equippedand are easy to use.

All condensers • can be used for bright field, dark field, phase, polarization and

interference contrast and feature • an aperture diaphragm• a mount for interchangeable condenser heads• a mount for a polarizer• a filter mount with a diameter of 32 mm

The S70/0.30 condenser features a free working distance of 70 mm and a numerical aperture of 0.30 and is particularlysuitable for high-volume specimens at magnifications of up to40x. An auxiliary lens is swung in for magnifications of 1.25x to 5xto provide homogeneous illumination all the way to the edge ofthe entire 25 mm field of vision.

The S28/0.55 condenser features a free working distance of 28 mm and a numerical aperture of 0.55 and offers the bestresolution and magnifications of up to 100x. Specimens with aheight of up to 28 mm can be examined in transmitted light. In addition to the standard contrast methods, this condenser isalso suitable for dark field contrast at objective apertures of upto 0.40.

S70 condensersManual• Coded manual condenser including head S70/0.30 11 522 089• Light ring set for phase contrast S70/0.30 11 522 090• Manual polarizer holder including polarizer 11 522 094• on 32/43 mm adapter for Wollaston prisms 11 522 093• Wollaston prisms for DIC see page 23

S28 condensersManual with fixed condenser head• Coaded manual condenser baser with fixed

mount for all condenser heads, S1–S28 11 522 006• Condenser head S28/0.55 11 505 234• Light ring set for PH and DF contrast S23–S28 11 521 505• Motorized polarizer holder including polarizer 11 522 103• Wollaston prisms for DIC see page 23

Focusing telescope (Fig. 69 p. 29)A focusing telescope is required when adjusting phase contrast(ICT) or differential interference contrast in order to view the rearfocal plane of the objective.

Focusing telescope dia. 30 mm 11 505 070

Fig. 65: S70 condenser

Fig. 66: S20 condenser

Fig. 67: S1 condenser

Fig. 68: S28 condenser head

Fig. 69: Focusing telescope

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 29

Page 30: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

30

Lamp mount for lamp housings as well as fiber opticor laser couplings

Depending upon the respective application, it is possible toadapt different lamp housing mounts for up to 3 ports at the rearside of the stand. The following distinctions apply:

Lamp mount for one lamp housing, or a fiber optic or lasercouplingErgonomically angled 90° to the right for optimal adjustment of lamp housings 11 504 135

Lamp mount for one lamp housing, or a fiber optic or lasercouplingUnder 0° for straight-through coupling 11 504 111

Manual mirror housing to accommodate two light sources, or fiber optic or laser couplings.Ergonomically angled 90° to the right for optimal adjustment oflamp housings and a straight position 11 504 108

Manual mirror housing to accommodate two light sources, or fiber optic or laser couplings.Ergonomically angled 90° to the left for optimal adjustment ofregular lamp housings and a straight position 11 504 109

Motorized mirror housing (for DMI 5000 M) (Fig. 70 p. 30)to accommodate 3 light sources, or fiber optic or laser couplings.Ergonomically angled 90° to the left and right for optimal adjust-ment of all Leica lamp housings and a straight position 11 504 107

Booster lens (for DMI 5000 M) (Fig. 71 p. 30)Depending on the application, a 180° turn of the switchableauxiliary lens (booster) provides either maximum fluorescenceintensity (factor: 1.4x in 75% center of field) or optimal homo-geneity and brightness distribution (factor: 0.7x for the entirefield). Suitable for insertion into the stand on the right or left,depending on order. 11 522 027

Reflector cube for lamp adjustment (Fig. 72 p. 30) 11 503 912

Fig. 71: Booster lens

Fig. 70: Motprized mirror housing (open)

Fig. 72: Reflector cube for lamp adjustment

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 30

Page 31: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

31

Light sources, lamp housing, supply unitsThe light sources are housed in lamp mounts, which are housedin lamp housings. The lamp housings are fastened to the standor transmitted-light illumination arm using a flange ring.This allows optimum heat decoupling and comfortable handling.The following equipment can be used:

For incident light and transmitted light:

Standard lamp housingLamp housing 107/2 (single-lens) (Fig. 73 p. 31)Plastic lamp housing with lamp access from above.With fixed, pre-centered lamp mount with 0.70 m power cableincluding 1x halogen bulb 12 V 100 W, single-lens aspherical,permanently set collector, heat-absorbing filter, microprism griddisk with middle diffuser for enlargement of the lamp filamentand optimization of the illuminated area, without reflector, without replacement lamp.11 504 104

Lamp housing 107/2 (single-lens) (as in Fig. 73 p. 31)as above, but with 2.5 m power cable 11 504 103

Lamp housing 107, left-hand operation (double-lens)(Fig. 74 p. 31)Plastic lamp housing with lamp access from above.With centerable lamp mount with 0.70 m power cable including1x halogen bulb 12 V 100 W, double-lens aspherical, focusablecollector, heat-absorbing filter, microprism with middle diffuserfor enlargement of the lamp filament and optimization of the illuminated area, without reflector, without replacement lamp.

11 504 102

Lamp housing 107, left-hand operation (double-lens) (as in Fig. 74 p. 31)as above, but with 2.5 m power cable 11 504 101

Lamp housing 106 (double-lens) (Fig. 75 p. 31)Metal lamp housing with side lamp access. With centerable lamp mount with 0.70 m power cable including1x halogen bulb 12 V 100 W, double-lens aspherical, focusablecollector, heat-absorbing filter, microprism with middle diffuserfor enlargement of the lamp filament and optimization of the illuminated area, without reflector, without replacement lamp.

11 504 058Lamp housing 106 (double-lens) (as in Fig. 75 p. 31)as above, but with 2.5 m power cable 11 504 059

Fig. 74: Lamp housing 107 (double-lens)

Fig. 73: Lamp housing 107/2 (single-lens)

Fig. 75: Lamp housing 106 (double-lens)

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 31

Page 32: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

32

Lamp housing 106z, left-hand operation – 12 V 100 W (4-lens)(Fig. 76 p. 32)Metal lamp housing with side lamp access.With centerable lamp mount with 0.70 m power cable including1x halogen bulb 12 V 100 W, four-lens, achromatic, focusablecollector, centerable reflector for doubling of the lamp fila-ment and optimization of the illuminated area, with heat-absorbing filter, without auxiliary lamp. 11 504 091

Lamp housing 106z – 12 V 100 W (4 lens) (as in Fig. 76 p. 32)As 11 504 091, but right-hand operation. 11 504 070

For fluorescence

Lamp housing 106z, left-hand operation – Hg 100 W (6-lens)Metal lamp housing with side lamp access. Left-hand operationfor DMI 5000 M.With centerable lamp mount for Hg 100 W lamp with 1.5 m power cable.6-lens, achromatic 1-inch collector, UV-optimized transmission > 50% at 340 nm, centerable reflector for doubling thefocal point and optimization of the illuminated area, with heat-absorbing filter, without burner. 11 504 106

Lamp housing 106z – Hg 100 W (6-lens)As 11 504 106, but right-hand operation. 11 504 114

Lamp housing 106z – Xe 75 W (6-lens)Metal lamp housing with side lamp access.With centerable lamp mount for Xe 75 W lamp with 1.5 m power cable.6-lens, achromatic 1-inch collector, UV-optimized transmission> 50% at 340 nm, centerable reflector for doubling the focalpoint and optimization of the illuminated area, with heat-absorbing filter, face protection, protective gloves, without burner. 11 504 105

Fiber-optics couplingA fiber-optics coupling can be connected between lamp mountand lamp housing. This "cold" light source prevents the standfrom heating up, which makes it particularly useful for long-termexperiments.• Fiber-optics coupling complete with 1 m fiber 11 504 112• Fiber-optics coupling complete with 2 m fiber 11 504 113

Lamps and burnersHalogen bulb 12 V 100 W (Fig. 77 p. 32) 11 500 974• High-pressure mercury burner Hg 100 W

(Fig. 79 p. 32) 11 500 138• High-pressure mercury burner Hg 100 W/2

(longer life) 11 500 321• Lamp HXP R120/45C-Vis

for Leica EL6000 11 504 120• High-pressure xenon burner Xe 75 W 11 500 139

Fig. 76: Lamp housing 106z – 12 V 100 W (4 lens)

Fig. 77: Halogen bulb 12 V, 100 W for lamphousing 106z

Fig. 78: Lamp mount for Hg 50 W

Fig. 79: Lamp mount for Hg 100 W

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 32

Page 33: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

33

Spacer for filter D = 50 mm (Fig. 80 S. 33)2 filter positions at LH 106/107, 4 filter positions with LH 106 z. Adapter between LH. 11 505 030

Additionally, for Xe 75 W lamp:Gray filter 0.2%D = 50 mm, 0.2% transparency, in holder 11 514 031

Diffusion filter ND = 50 mm, embossed, in holder. 11 514 042

Additional filters D = 50 mm in holder:• DLF, daylight filter 11 514 755• ALF, artificial light filter 11 514 756• Panchromatic green filter 11 542 131• VG 9, green filter 11 514 041• Neutral gray filter N20 (5%) 11 514 036• Heat-absorbing filter 11 514 027

Supply units

For power supply voltages other than 220–240 V, the following is required:Pre-transformer 100–120 V With power supply cord, primary 100–120 V, secondary 220–230 V 11 500 316

Supply unit Hg 100 W (Fig. 82 S. 33)With power supply cord, automatic switching to power supplyvoltage 90 V–250 V 50/60 Hz with operating hours display.

11 500 325

Supply unit Xe 75 W With power supply cord, automatic switching to power supplyvoltage 90 V–250 V 50/60 Hz with operating hours display.

11 500 324Leica EL6000 (Fig. 83 S. 33)• External light source 11 504 115• Liquid light guide, 2 m 11 504 116• 1-inch fiber optics adapter for lampmounts. 11 504 117• 1-inch fiber optics adapter direct at the DMI 11 504 136• Cable for shutter control EL6000 I2C 11 500 331

Abb. 83: Leica EL6000

Fig. 80: Filter and spacer for filter d= 50 mm

Fig. 81: Polarizer protective filter

Fig. 82: Supply unit Hg 100 W

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 33

Page 34: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

34

TV adapterYou can adapt analog and digital cameras to all tubes with docu-mentation output. The C-B and F-mount adapters are aligned tothe dimensions of the holder thread. The various fixed and vari-able magnification factors allow adjustment of the rendering ofthe microscopic image on the camera chip. In order to displaythe largest possible portion of the field of view on the monitor,the magnification factor of the adapter must fit the chip size ofthe camera. If the magnification is too low, there will be a lack ofuniformity to the illuminated area (shading) and/or vignetting.

Diagonal measurements of images taken (in mm) at

1 inch- 2/3 inch- 1/2 inch- 1/3 inch- Order No.camera camera camera camera

Without variable magnification, only for single chip cameras:C-mount adapter 1x HC 16 11 8 6 11 541 510C-mount adapter 0.7x HC – 15.7 11.4 7.8 11 541 543C-mount adapter 0.55x HC – – 14,5 10.9 11 541 511C-mount adapter 0.35x HC – – – 17.1 11 541 512

With variable magnification (vario TV adapter) for 1–3 chip cameras:C-mount, 0.32–1.6x HC – – 19*–5 18–3.8 11 541 517B-mount (ENG), 0.5–2.4x HC (1/2 inch) – – 16–3.3 – 11 541 518

Without variable magnification level, only for 1-3 chip cameras:C-mount adapter 1x – – 16 12 11 543 706B-mount adapter 1x – – 16 12 11 543 702B-mount adapter 1.25x – 17.5 – – 11 541 539F-mount adapter 1x – – 16 12 11 541 540F-mount adapter 1.25x – 17.5 – – 11 541 541required for each: TV optics 0.5x HC 11 541 538

* available beginning with vario factor 0.42x!

Fig. 84: TV adapter

Fig. 85: TV adapter

Fig. 86:C-mount 0.63x HC

Fig. 87:C-mount 0.5x HC

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 34

Page 35: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

35

Objectives, objective turret,opticsObjectivesThe optics are the heart of every microscope and are decisivefor the quality of the image information. Leica has set standardsin this respect with the introduction of HC optics. Eyepieces, tubelenses and objectives have been carefully harmonized with oneanother.Based on the Leica principle of infinity distance correction ofoptics, the microscope objectives are infinity corrected for tubelens systems with 200 mm reference focal lengths. The calibration length is 45 mm for bright field.The objectives are divided into 4 correction classes:• Achromatic objectives: HI PLAN

Field of view performance up to FOV 20• Planachromatic objectives: N PLAN

Field of view performance up to FOV 22• Semi-apochromatic objectives: HC/X PL FLUOTAR

Field of view performance up to FOV 25• Apochromatic objectives HC/X PL APO

Field of view performance up to FOV 25When selecting the objectives, consider the intended use withregard to specimen covering, etc. For applications in the industrial field, this cover glass correction is "0". For more detailed explanations, please refer to http://www.leica-microsystems.com/objectives.

Objective turretIn principle, all infinity corrected high-performance Leicaobjectives with an M32 or M25 thread may be used. Even olderobjectives can be adapted for further use. Adapter rings forobjectives with RMS or M25 thread are also available.Objectives of earlier lines with RMS threads cannot be adaptedunconditionally, however, as problems with parfocality and fieldflattening may arise.

• Adapter M32/M25 11 561 003• Adapter M32/RMS 11 562 281

Numerous application objectives with long working distances(L objectives) are available specifically for inverted microscopy.The following table lists all objectives of the Leica program.The focusing of the specimen is carried out via the objectiveturret that can be fitted with up to 5 objectives (M32). The reliable,stable and precise focusing is not affected by the stage and itsspecimens or accessories.

Fig. 88: Objective turret

Fig. 89: Adapter for RMS-threaded objectives

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 35

Page 36: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

36

Accessories

Immersion oil, 10 mlFree of natural fluorescence as per ISO 8036/1, refraction index ne

23 = 1.5180 ± 0.005, dispersion ve23 = 44 ± 2 11 513 859

Immersion oil, 20 mlas per ISO 8036/1, refraction index ne

23 = 1.5180 ± 0.005, dispersion ve

23 = 44 ± 2 11 513 860

Immersion oil, 250 mlas per ISO 8036/1, refraction index ne

23 = 1.5180 ± 0.005, dispersion ve

23 = 44 ± 2 11 513 861

Stage micrometerTransmitted light 2 mm = 200 parts 11 513 106

Stage micrometerIncident light 1 mm = 100 parts 11 563 011

Focusing telescope dia. 30.0 mm 11 505 070

Halogen lamp 12 V 100 W 11 500 974

Hg 50 W burner 11 500 137

Hg 100 W/2 burner 11 500 321

Xe high-pressure burner 11 500 139

Screw cap for unused objective mounts (Fig. 90 p. 36)Component of stand 11 020-422-580-028

Cover for unused objective DIC-disk opening (Fig. 91 p. 36)Component of stand 11 090-144-020-088

Dust and light excluder for analyzer opening (Fig. 92 p. 36)Component of stand 11 020-437-101-013

Dust and light excluder for camera port opening (Fig. 93 p. 36)Component of stand 11 020-387-556-009

Ergonomic height compensation plateTo increase the viewing height by 20 mm, or to increase the lateral camera ports for oversized cameras, a height compensation plate was developed.Height compensation plate: 12 mm 11 522 031Height compensation plate: 25 mm 11 522 036

Fig. 90: Screw cap

Fig. 91: DIC cover

Fig. 93: Camera port cover

Fig. 92: Analyzer opening cover

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 36

Page 37: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

37

Anti-vibrationAnti-vibration tableAnti-vibration table for DMI series with massive marble insert.The insert comes with a hole to use the Leica DMI stands withbottom-port 11 522 055

Vibration Isolation Platform (Fig. 94 p. 37)VIP Series 3000 from VistekTM for DMI stands to isolate themicroscope from external vibrations. The platform is designed for routine tabletop use. 11 532 404

Digital image documentationLeica digital camera system DCMonochrome and color digital cameras for all requirementsbetween highest resolution (12 megapixels) and quick live image(25 frames per second)(see special brochures)

SoftwareThe LAS (Leica Application Suite) is the PC interface for theconfiguration, operation, evaluation and storage of microscopedata and images.

LAS, Basis Package 11 888 375

Weitere Module:• LAS Steel Expert Auto -

for fully automatic steel inclusion rating 12 730 069• LAS Steel Expert Manual -

manual steel inclusion rating 12 730 068• LAS Reticule 12 730 065• Leica Materials Workstation Environment -

basic module of Materials Workstation 12 723 612• Leica QHardness interactive 12 723 827• Leica QParticles - for particle analysis 12 723 703• Leica Metallurgy Suite 12 723 613

Includes the following 5 modules :Part numbers indicated forthese modules refer to the individual module

• Leica QGrain - grain size analysis 12 723 614• Leica Graphite - for the determination of

nodular graphite 12 723 615• Leica Phase Percent - measuring of phase percent 12 723 616• Leica Coating Thickness - determination of

coating thicknesses 12 723 617• Leica Depth -

for the determination of decarburisation 12 723 618

Fig. 94: Vibration Isolation Platform

Fig. 95: Leica DFC Camera

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 37

Page 38: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

38

SystemoverviewLeica DMI3000 MLeica DMI5000 M

0.5x

Leica DC150

Leica DC180

Leica DFC280

Leica D(F)C300 (F/X)

0,5–

2,4x

0,33

–1,6

x

0,35

x

0,55

x

0,70

x

1x

11 5

41 5

18

11 5

41 5

17

11 5

41 5

12

11 5

41 5

38

11 5

41 5

44

11 5

41 5

43

11 5

41 5

10

11 541 540F-mount

1/2

11 541 541F-mount

2/3

11 543 706C-mount

1/2

11 543 702B-mount

1/2 Sony

11 541 539B-mount

2/3 Sony

1x1x 1x1.25x 1.25x

Leica DC500

Leica DFC320

Leica D(F)C350 (F/X)

Leica D(F)C480

C-mount adapter HC

TV systems

Digital cameras, see Special brochures

ENG(

B) m

ount

HC

C-m

ount

HC

11

11 888 373Bino-fix tube11 888 372Bino-ergo tube

2

Bino tube

11 888 368with 50/50Photo output11 888 324with 100 %Photo output

2

11

Trino-ergo tube

11 504 101Lamp housing LH107 Left12 V 100 W Halogen (2.5 m)

11 504 102Lamp housing LH107 Left12 V 100 W Halogen (0.7 m)

11 504 103Lamp housing LH107/212 V 100 W Halogen (2.5 m)

11 504 104Lamp housing LH107/212 V 100 W Halogen (0.7 m)

11 504 059Lamp housing LH10612 V 100 W Halogen (2.5 m)

11 504 058Lamp housing LH10612 V 100 W Halogen (0.7 m)

11 504 091Lamp housing LH106z Left12 V 100 W Halogen (0.7 m)

11 504 070Lamp housing LH106z12 V 100 W Halogen (0.7 m)

Incident light/transmitted lightlamp housings

5

11 504 107Motorized mirror housing with 3 inputs

11 504 108Manual mirror housing right/straight

11 504 109Manual mirror housing left/straight

11 504 135Lamp adapter 90 right

11 504 111Lamp adapter straight

Lamp housing mount4

11 504 106Lamp housing 106z L 6 LensesHg 100 W 1 Inch collector

11 500 325Supply unitHg 100 W

11 500 324Supply unitXe 75 W

11 504 115External lightsource EL6000

11 504 114Lamp housing 106z 6 LensesHg 100 W 1 Inch collector

11 504 105Lamp housing 106z L 6 LensesXe 100 W 1 Inch collector

11 504 1171-inch fiber-opticsadapter

11 504 116Gel fiber-optics, 2 m

Fluorescence lamp housings5 12

11 505 180Remote controlSmartMove

11 888 164Supply unitCTR4000

Supplyunit CTR6000

11 888 821

11 505 180Remote controlSmartMove

11 888 822Supply unitCTR6500(when usedwith spindlescanning stages)

5

10

12

6

8

FDAP

TL/L

INT

3 91

Base standDMI5000 Mwith motorized focus11 888 724

7

4

11

1

6

8

FDAP

TL/L

INT

3

11

10

Base standDMI5000 Mwith manual focus 11 888 725

7

12

4

9

5

1

6

8

3

11

12

Base standDMI3000 Mwith manual focus 11 888 730

7

12

4

9

5

11 501 255SmartTouch panelSTP6000

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 38

Page 39: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

39

8IL objective prisms Analyzer

11 522 048Man. DIC objective prism disk, for DMI3000/5000 MObjective prisms (A, C, C1, C2, D, D1, E)

IL objective prisms Analyzer

11 522 049Mot. DIC objective prism disk, for DMI5000 MObjective prisms (A, C, C1, C2, D, D1, E)

Polarizer

Polarizer

DIC systems

211 505 070Focusing telescope

– Eyepieces– Reticle graticules– Stage micrometer

(for order numbers see module brochure)

Eyepieces

3

5x objective mount M32

11 513 860Immersion oil 20 ml

Objectives

11 888 6991.5x magnification

11 888 3771.6x magnification

11 888 3762.0x magnification

Reflectors(for order numbers see module brochure)

11 888 7264-fold mot. reflector turret,1x tube lens and magnification changer

6

Reflectors(for order numbers see module brochure)

Incident light axis and magnification changer

11 888 7274-fold mot. reflector turret,with 1x tube lens

Incident light filter slide7

11 522 028Filter slide IL

Ø 25 mm filter see module brochure

1Transmitted light axis

Light filter Ø 40 mmman.

1

5

1b11 888 381Manual illumination armfor DMI5000 Mincl. man. field diaphragm,man. shutter, man. filtermagazine

Light filter Ø 40 mmman.

11

5

1b1b11 888 380Manual illumination armfor DMI3000 Mcoded, incl. man. field diaphragm,man. shutter, man. filtermagazine

Light filterØ 40 mmman.

11 888 366Manual illumination armintegrated 30 W Lamphousingfor DMI3000 Mincl. man. field diaphragm,man. shutter, man. filtermagazine

9

11 522 078Regular fiexed stage

11 522 014Objective guide forspecial holder frame

Special holder frame

Stages

Rectangular inserts10 mm, 20 mm, 40 mm inserts

11 522 604Regular 3-plate stage

11 522 603Motorized3-plate stage

Rectangular inserts10 mm, 20 mm, 40 mm inserts

11 522 602Scanning stage

11 505 106Cable set for scanning stage(without ill.)

Side ports DMI5000 M

11 888 391Motorized side portleft only

11 888 392Motorized side portright only

11 888 393Motorized side portright and left

11 888 256Port compensation moduleno side port

11 888 259: Side port prism 100% left11 888 260: Side port prism dichroic 630 nm left11 888 262: Side port prism 80% left11 888 264: Side port prism 50% left

11 888 258: Side port prism 100% right11 888 261: Side port prism 80% right11 888 263: Side port prism 50% right

11 888 258: Side port prism 100% right11 888 259: Side port prism 100% left11 888 261: Side port prism 80% right11 888 262: Side port prism 80% left11 888 263: Side port prism 50% right11 888 264: Side port prism 50% left

10

12

Condensers1b

11 521 506Light ring set Condenser prisms

11 522 009Mot. polarizer

11 522 004Mot. condenser base S1–S28with pivoting head

11 521 500Condenser headS23/0.52

11 505 175Condenser headS28/0.55

S1–28 mot.

11 521 506Light ring set Condenser prisms

11 522 024Adjustment lens for low magnification

11 521 5153x Filter holderFilter Ø 32 mm

11 522 010Man. polarizer

11 522 008Man. condenser S70

Filter in holderØ 32 mm

S70 man.

Side ports DMI3000M

11 888 389: Manual left side port 100/011 888 388: Manual left side port 80/20

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 39

Page 40: Leica DMI3000M Leica DMI5000Mimg3.app17.com/Down/20140912/201409120151406632.pdf · 3 Leica DMI Series – Basic stands The Leica DMI Series is the rigorous further development of

eica Microsystems –the brand for outstanding products

Orde

r nos

. of t

he e

ditio

ns in

: Eng

lish

914

660

•Ge

rman

914

659

•Pa

rt-N

o. 5

01-2

77 •

VIII/

08/?

??/?

???

•LE

ICA

and

the

Leic

a Lo

go a

re re

gist

ered

trad

emar

ks o

f Lei

ca IR

Gm

bH.

Leica Microsystems’ mission is to be the world’s first-choice provider of innovative solutions to ourcustomers’ needs for vision, measurement and analysis of micro-structures.

Leica, the leading brand for microscopes and scientific instruments, developed from five brandnames, all with a long tradition: Wild, Leitz, Reichert, Jung and Cambridge Instruments. Yet Leicasymbolizes innovation as well as tradition.

Leica Microsystems – an international companywith a strong network of customer servicesAustralia: North Ryde Tel. +61 2 8870 3500 Fax +61 2 9878 1055

Austria: Vienna Tel. +43 1 486 80 50 0 Fax +43 1 486 80 50 30

Belgium: Groot Bijgaarden Tel. +32 2 790 98 50 Fax +32 2 790 98 68

Canada: Richmond Hill/Ontario Tel. +1 905 762 2000 Fax +1 905 762 8937

Denmark: Herlev Tel. +45 4454 0101 Fax +45 4454 0111

France: Rueil-Malmaison Tel. +33 1 47 32 85 85 Fax +33 1 47 32 85 86

Germany: Wetzlar Tel. +49 64 41 29 40 00 Fax +49 64 41 29 41 55

Italy: Milan Tel. +39 0257 4861 Fax +39 0257 40 3475

Japan: Tokyo Tel. + 81 3 5421 2800 Fax +81 3 5421 2896

Korea: Seoul Tel. +82 2 514 65 43 Fax +82 2 514 65 48

Netherlands: Rijswijk Tel. +31 70 4132 100 Fax +31 70 4132 109

People’s Rep. of China: Hong Kong Tel. +852 2564 6699 Fax +852 2564 4163

Portugal: Lisbon Tel. +351 21 388 9112 Fax +351 21 385 4668

Singapore Tel. +65 6779 7823 Fax +65 6773 0628

Spain: Barcelona Tel. +34 93 494 95 30 Fax +34 93 494 95 32

Sweden: Kista Tel. +46 8 625 45 45 Fax +46 8 625 45 10

Switzerland: Heerbrugg Tel. +41 71 726 34 34 Fax +41 71 726 34 44

United Kingdom: Milton Keynes Tel. +44 1908 246 246 Fax +44 1908 609 992

USA: Bannockburn/lllinois Tel. +1 847 405 0123 Fax +1 847 405 0164

and representatives of Leica Microsystemsin more than 100 countries.

Leica Microsystems operates internationally in four divi-sions, where we rank with the market leaders.

• Life Science Research DivisionLeica Microsystems’ Life Science Research Division sup-ports the imaging needs of the scientific community withadvanced innovation and technical expertise for the visu-alization, measurement and analysis of microstructures.Our strong focus on understanding scientific applicationsputs Leica Microsystems’ customers at the leading edgeof science.

• Industry DivisionThe Leica Microsystems Industry Division’s focus is tosupport customers’ pursuit of the highest quality endresult by providing the best and most innovative imagingsystems for their needs to see, measure and analyze themicrostructures in routine and research industrial appli-cations, in materials science and quality control, in foren-sic science investigations, and educational applications.

• Biosystems DivisionThe Biosystems Division of Leica Microsystems bringshistopathology labs and researchers the highest-quality,most comprehensive product range. From patient topathologist, the range includes the ideal product for eachhistology step and high-productivity workflow solutionsfor the entire lab. With complete histology systems fea-turing innovative automation and Novocastra™ reagents,the Biosystems Division creates better patient care throughrapid turnaround, diagnostic confidence and close cus-tomer collaboration.

• Surgical DivisionThe Leica Microsystems Surgical Division’s focus is topartner with and support micro-surgeons and their careof patients with the highest-quality, most innovative surgi-cal microscope technology today and into the future.

www.leica-microsystems.com

Leica BK DMI3000-5000_M_englisch.qxd:BAU5000_en.qxd 31.07.2008 11:39 Uhr Seite 40